BRR : 10265297
Tender Brief : Work Under System Augmentation Plan In Sub Division First Under Ee, Edd, Barabanki.- 1 Safe Loading Carriage Including Unloading And Proper Stacking Of Following Materials From Central Store Barabanki / Je Store To Site Of Work. 2 Pcc / St Pole 3 11Kv Pin Insulator . 4 11Kv Disc Insulator . 5 Top Channel 11 Kv 6 T-Off Channel 11 Kv 7 11Kv X-Arm 8 Ms Earthing Rod 9 Transformer 100Kva 10 Transformer 400Kva 11 Ltcable Al 1X240 Sq Mm 12 Ltcable Al 1X400 Sq Mm 13 Ltcable Al 1X630 Sq Mm 14 Acsr Rabbit Conductor 15 11 Kv 3*185 Sq Mm Xlpe Cable 16 11 Kv Vcb Panel O... Read More
Tender Value
₹
62,00,000
Submission Date
03-10-2023
Participated Bidder List
3 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 57,95,179 | L2 | |||
| 2 | cnet-technologies | Bid Analytics | 56,78,895 | L1 | |||
| 3 | cnet-technologies | Bid Analytics | 59,00,950 | L3 |
Work Detail
work under system augmentation plan in sub division first under ee, edd, barabanki.- 1 safe loading carriage including unloading and proper stacking of following materials from central store barabanki / je store to site of work. 2 pcc / st pole 3 11kv pin insulator . 4 11kv disc insulator . 5 top channel 11 kv 6 t-off channel 11 kv 7 11kv x-arm 8 ms earthing rod 9 transformer 100kva 10 transformer 400kva 11 ltcable al 1x240 sq mm 12 ltcable al 1x400 sq mm 13 ltcable al 1x630 sq mm 14 acsr rabbit conductor 15 11 kv 3*185 sq mm xlpe cable 16 11 kv vcb panel outgoing ctr 200 / 100 / 5 a, 350 mva 17 11 kv vcb incomming ctr 600 / 300 / 5 a, 350 mva 24 volt. 18 stay set complete 19 other line material 20 dragging of pole from je dump store to work site 21 concreating and pilinthing of st& pccpole 18x24 cm. 22 erection of stay set of 16x1800 mm rod duly painted with red oxide, anchor plate, thumble turn buckle andstay insulate etc. digging of pit of size of size 0.4x0.6x1.6 m for grouting 1:3:6 cement concrete, with stay of size 7 / 8 swg, nuzzling & grouting. 23 stringing and sagging of 11 kv line with acsr rabbit conductor including nuzzling binding and jumpering ( rabbit conductor will be provided by the department ) 24 errectionof substation type double pole with pcc pole 8.5 mtr. long including mounting of top channal dropper channel, base angle with clamps with nut & bolt 33 / 11 kv line including grouting of support and plinthing 300 mm above ground level, fitting of 33 / 11 kv pin & pin insulator. 1 / 6 of total lenght of poles will remain under the ground and planted on stone pad of size 300x300x75 mm. 25 errectionof singlepcc / st pole for stringing and sagging of conductor 1 / 6 of total length of poles will remain under the ground and planted on stone pad of size 300x300x75 mm. 26 earthing of pole with ms earthing. 27 fabricate with hole suitable size in steel items, receive from central store lightas top channel / dropper channel sub station base angle etc. 28 installation of mounting of following capacityof transformer including its connection between 11 kv and lt line mounting of copper l-pieces, provinding crimping type aluminium lugs of required size. ( all the material except transformer will be arranged by the contractor ) 29 mounting of 100 kva tranformer and its connection complete 30 mounting of 400 kva tranformerits connection complete 31 provindingof various type materials. all materials shall be supplied by the contractor. 32 nut & bolt off sizes 33 11 kv do fuse set. 34 11 kv tpmo set complete 35 clamp for top / dropper and t-off channel etc. 36 different size of lug 120 / 240 / 400 / 630 / 1000 sq mm 37 copper lug 120 mm 38 copper l piece 250 / 400 / 630 kva 39 lt xlpe cable 3.5x240 sq mm. 40 copper controlwire 6mm wire 41 copper control cable 2mm 4 wire 42 copper control cable 4mm 4 wire 43 copper control cable 6mm 4 wire 44 copper control cable trey 3.5x50 sq mm 45 ltxlpe cable al 1x240 sq mm 46 ltxlpecable al 1x400 sq mm 47 ltxlpecable al 1x630 sq mm 48 construction of masonry type distribution pillar box with first class brick ballast cement, coarse sand, local sand, brick ballast and ms round bar of 10 mm dia including supply and mounting of 02 nos. straight ms angle 50x50x6x750 mm- 2 / 3 nos., henely type tailless fuse units 500 amps. 650 volts one no. for incoming and other for outgoing, al bus bar 4 nos. 1000x50x6 mm with locking arrangement made of 18 swg bp sheet. all material will be supplied by the contractor 49 fixing of various type materials. all t& p and labour will be provided by the contractor. 50 nut & bolt 51 11 kv do fuse set. 52 11 kv tpmo set 53 clamp for top / dropper and t-off channel etc. 54 different size of lug 55 copper lug 120 mm 56 copper l piece 250 / 400 / 630 kva 57 lt xlpe cable 3.5x240 sq mm. 58 copper controlwire 6mm wire 59 copper control cable 2mm 4 wire 60 copper control cable 4mm 4 wire 61 copper control cable 6mm 4 wire 62 copper control cable trey 3.5x50 sq mm 63 ltxlpe cable al 1x240 sq mm 64 ltxlpecable al 1x400 sq mm 65 ltxlpecable al 1x630 sq mm 66 installation of 11 kv vcb panel outgoing ctr 200 / 100 / 5 a, 350 mva 67 installation of 11 kv vcb incomming ctr 600 / 300 / 5 a, 350 mva 24 volt. 68 ltcable al 1x240 sq mm 69 ltcable al 1x400 sq mm 70 ltcable al 1x630 sq mm 71 wiremessfencing of 11 / 0.4 kvs / s shall be made of rectangular of size as per site requirement not exceeding 3 meter fabrication 45x45x5 mm angle the frame is also have 1 no. horizontal runner of ms flat 40x5 welded in middle to support of wire mess. rectangular welded type wire mess of size 50x25 made of 12 s.w.g. wire mess shall be welded all along the periphery of theframe as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. diagonal bracing of all the frame panel will be welded with ms flat of size 25x3mm to support as per respo specification & direction of e / i 72 repairing of wiremessfencing of 11 / 0.4 kvs / s shall be made of rectangular of size as per site requirement not exceeding 3 meter fabrication 45x45x5 mm angle the frame is also have 1 no. horizontal runner of ms flat 40x5 wherever required welded in middle to support of wire mess. rectangular welded type wire mess of size 50x25 made of 12 s.w.g. wire mess as per actual requirement shall be welded all along the periphery of theframe with proper grouting & plinthing of angle support as per respo specification & direction of e / i 73 construction of t / f plinth of size 2x2x1.5 mtr with first class brick and massionary work in the ratio 1:4 cement and core sand with rcc top 20 mm 1:2:2cement sand & core sand stone grit with 20 mm ms bar and ms channel for resting of t / f. all material will be provided by the contrator 74 earthing of t / f pipe type with 40 fit deep borring and providing gi pipe 1.5 dia ( 60 fit gi pipe ) and gi strip 25x5 mmx6 meter long attached with clamps, l piece, nut & bolts and gi pipe cap. all material shall be supplied by the contractor. 75 testing of control pannel 76 dismentaling of 63 / 100 / 250 kva t / f & carriage site to store 77 dismentaling& shifting of 250 kvat / f 78 laying of 11 kv 3*185 sq mm xlpe cable by open trenching as per resspo 79 other line work
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Financial Evaluation In Progress
Financial bids are currently under review. Awarded bidder information will be published after final evaluation.
PriceBid
Similar Tenders Results