View Bid Results For Maintenance For Air Condition Plant Tenders

We found 517 Bid Results related to maintenance for air condition plant tenders. You can find Contractor details who won maintenance for air condition plant tenders along with contract details in Bid awards announcements section.

Filters
Stage
408
67
42
Tender Publishing Platform
39
478
State / UT
31
153
62
52
35
27
19
18
16
13
13
12
10
10
9
9
9
8
7
6
5
4
4
3
2
2
2
2
2
1
1
1
Contract Value
189
44
176
106
Publish Date
1
0
0
0
0
Sector
24
137
135
76
31
25
23
16
14
9
9
8
6
5
5
4
3
3
2
1
1
1
1
1
1
Ownership
4
286
138
52
41
Within keyword
Active filters:
Showing 1–11 of 517 tenders matching your filters
1.
Health and Family Welfare #11427982 Technical Bid
Tender for E-Tender For Purchase Of Mediciens, Dental Materials, Consumables, Lab Items, Ortho Implants & Other Items For Districit Health Facilities, District Charkhi Dadri. , 5-Fluorouracil Injection 500Mg, 50Mg/Ml Ampule , Acebrophylline 200 Mg Tablet , Aceclofenac Tablet 100 Mg , Acetazolamide Tablet 250 Mg , Acetylcysteine 600Mg Tablet , Acetylcysteine20% W/V, 2Ml Injection , Acetylsalicylic Acid Tablet 150 Mg , Acetylsalicylic Acid Tablet 75 Mg Gastroresistant Entric Coated , Actinomycin Injection 0.5 Mg , Acyclovir Eye Oint 5%,5 Gm , Acyclovir Ointment 3% W/W, 4.5Gm , Acyclovir Tablet 200 Mg , Acyclovir Tablet 400 Mg , Acyclovir Tablet 800 Mg , Adapalene Gel, 0.1%, 15Gm , Adenosine Injection 3 Mg/ Ml, 1Ml annual periodical maintenance , Adrenaline Injection 1 Mg/Ml, 1:1000, 1 Ml annual periodical maintenance , Agomelatine Tab 25 Mg , Albendazole Chewable Tablet 400 Mg , Albendazole Oral Suspension 200 Mg/5 Ml,10 Ml Bottle , Alfacalcidol Soft Gelatin Capsule 0.25 Mcg , Alkalizer Mb6 500Ml (Potassium Citrate Magnisum Citrate Syrup & Vit B6) , Allopurinol Tablet 100 Mg , Alprazolam Tablet 0.25 Mg , Alprazolam Tablet 0.5 Mg , Aluminium Hydroxide + Magnesium Hydroxide + Simethicone Oral Solution 250 Mg+ 250 Mg+ 50 Mg/ 5 Ml, 180 Ml Bottle , Aluminium Hydroxide + Magnesium Hydroxide + Simethicone+ Magnesium Carbonate Chewable Tablet 240 Mg+100 Mg+ 25 Mg + 60 Mg , Amidarone 150 Mg/3 Ml Injection , Amikacin Injection 100Mg, 2 Ml , Amikacin Injection 250Mg, 2 Ml , Amikacin Injection 50 Mg, 2 Ml , Amikacin Injection 500Mg, 2Ml , Amino Acids/Alamin 200 Ml Infusion Iv Minimum 10 Essential Amino Acids , Aminophylline Injection 25 Mg/ Ml, 10 Ml Ampoule , Amiodarone 100 Mg Tablet , Amiodarone 200 Mg Tablet , Amisulpride 100 Mg Tablet , Amisulpride 200 Mg Tablet , Amisulpride 50 Mg Tablet , Amitriptyline Tablet 10 Mg , Amitriptyline Tablet 25 Mg , Amlodipine Tablet 10 Mg , Amlodipine Tablet 5 Mg , Amoxicillin + Clavulanic Acid Injection 1.2 Gm , 10 Ml Vial With Diluents , Amoxicillin + Clavulanic Acid Injection 250 Mg +50 Mg, Vial With Diluents , Amoxicillin + Clavulanic Acid Suspension 200 Mg +28.5 Mg/ 5 Ml, 60 Ml Bottle , Amoxicillin + Pottasium Clavulanate Dispersible Tablet 200 Mg +28.5 Mg , Amoxicillin + Pottasium Clavulanate Tablet 500 Mg + 125 Mg , Amoxicillin Capsule 250 Mg , Amoxicillin Oral Suspension 125 Mg/5 Ml, 60 Ml Bottle , Amphotericin B Powder For Injection 50 Mg And Vial Has Sodium Deoxychlolate Or Liposomal Complex, 10 Ml , Ampicillin Sodium Injection 500Mg/2 Ml Vial With Diluent , Anti Hemophillic Factor Ix Vial Injection Size 500 Iu , Anti Hemophillic Factor Vii Injection 1Mg,Vial/Ampoule , Anti Hemophillic Factor Vii Injection 2Mg,Vial/Ampole , Anti Hemophillic Factor Viii Inhibitor Bypassing Agent Injection 1000 Iu,Vial/Ampoule , Anti Hemophillic Factor Viii Inhibitor Bypassing Agent Injection 500 Iu,Vial/Ampoule , Anti Rabies Immunoglobulin Injection (Human) 150 Iu/Ml, 2Ml Vial , Anti Rabies Immunoglobulin Injection 300Iu/Ml , Anti Rabies Vaccine Human (Cell Culture) Purified Vero Cell Rabies Vaccine 1 Ml Vial, (For Intradermal Use) , Anti Rabies Vaccine Injection 2.5 Iu, Singledose , Anti-Haemorrhoidal Containing: Beclomethasone Dipropionate 0.025% W/W, Phenylephrine Hyderochloride 0.10% W/W, Lignocaine Hydrochloride 2.5% W/W In Soft Paraffin Base 20 Gm Tube , Anti-Rho-D Immunoglobulin(Human) Injection (Polyclonal) Injection 150 Mcg/Vial , Anti-Rho-D Immunoglobulin(Human) Injection (Polyclonal) Injection 300Mcg/Vial , Antisnake Venom ( Dry Powder For Polyvalent Solution) Injection Vial With 10 Ml Diluent , Antisnake Venom (Polyvalent Solution) Injection 10 Ml , Aprepitant 80Mg (Kit Contains 3 Caps) , Aripipralzole Tablet 10 Mg , Aripiprazole Tablet 20 Mg , Aripiprazole Tablet 5 Mg , Arkamin 0.1 Mg Tablet , Artemether (40Mg) + Lumefantrine (240Mg) Tablet , Artemether (80Mg) + Lumefantrine (480Mg) Tablet , Artesunate 100 Mg+Pyrimethamine 37.5 Mg+Sulphadoxin 750 Mg Tab. , Artesunate 50 Mg+Pyrimethamine 25 Mg+Sulphadoxin 500 Mg Tab. , Artesunate 200 Mg+Pyrimethamine 25 Mg+Sulphadoxin 500 Mg Tab. , Artesunate Injection 60 Mg/Ml , Ascorbic Acid Tablet 500 Mg (Vitamin - C) , Ascorbic Acid Tablet 500 Mg + Zinc Sulphate 20Mg , Atenolol Tablet 50 Mg , Ateplase Inj. 20 Mg , Ateplase Inj. 50Mg , Atomoxetine Capsule 10 Mg , Atorvastatin Tablet 10 Mg , Atorvastatin Tablet 20 Mg , Atracurium Besylate Injection 10 Mg/ Ml, 2.5 Ml , Atropine Eye Drops 1% W/V, 5 Ml , Atropine Eye Ointment 1%, 3.5 Gm , Atropine Injection 0.6 Mg/Ml, 1 Ml Ampoule , Azathioprine 25 Mg Tablet , Azithromycin 1Gm Inj. , Azithromycin 500 Mg Inj. , Azithromycin Oral Solution 200 Mg/5 Ml, 15 Ml , Azithromycin Tablet 250 Mg , Azithromycin Tablet 500 Mg , Azitronam 250Mg , B-Complex Tablet , Beclofen Tablet 20 Mg , Benzathine Penicillin Injection (Powder )12 Lacs Iu Vial, 5 Ml , Benzoyl Per Oxide Gel 2.5%, 20 Gm , Benzyl Nicotinate(2 Mg) + Heparin(50 Iu) 20Gm Ointment (Tharomophob Cream) , Betahistine Tablet 8 Mg , Betamethasone Dipropionate Cream 0.1 %, 5 Gm , Betamethasone Injection 4Mg/Ml , Bethanecholchloride Tablet 25 Mg , Bicalutamide Tablet 50 Mg , Biotin Tablet 10 Mg , Biphasic Isophane Insulin (30/70) 40 I.U/Ml, 10 Ml , Bisacodyl Tablet 5 Mg , Bisprolol 5Mg Tablet , Bleomycin Injection 15 Mg, 15 Mg/Ml Vial , Blonanserin Tablet 4 Mg , Bone Marrow Needle For Neonates 18 G , Bortezomib Injection 2 Mg , Breviteracetam Tablet 50 Mg , Bromocriptine Tablet 2.5 Mg , Budesonide (A)+ Formoterol (B) Inhalation (Mdi/Dpi) 200 Mcg (A)+ 6 Mcg (B), 120 Mdi , Budesonide Inhalation (Mdi/Dpi) 200 Mcg/Dose, 200 Mdi , Budesonide Nasal Spray 100 Mcg/Dose, 7.5 Ml , Budesonide Respirator Solution For Use In Nebulizer 1 Mg/ Ml, 2Ml , Budesonide Respules 3%, 4Ml , Bupivacaine Heavy 5 Mg With Dextrose Monohydrate 80 Mg/Ml Injection 4 Ml Ampoule , Bupivacaine Injection 0.5%, 5Ml Amp. , Buprenorphine Tablet 0.4 Mg , Buprenorphine Tablet 2 Mg , Buprenorphine Transdermal Patch 10 Mcg/Hour , Buprenorphine Transdermal Patch 20 Mcg/Hour , Buprinorphine Patch 10 Mg , Buprinorphine Patch 15 Mg , Buprinorphine Patch 5 Mg , Bupropion Tablet 150 Mg , Buspirone 5 Mg Tablet , Butorphanol Tartrate 1Mg/Ml, 1 Ml Injection , Cabergolin 0.25 Mg Tab , Cabergolin 0.50 Mg Tab , Caffeine Citrate 20Mg/Ml Oral Solution , Caffeine Citrate Injection 20 Mg/Ml (Equivalent To 10 Mg Caffeine Base/Ml), 3Ml , Calamine Lotion, 100 Ml , Calcium Gluconate Injection 100 Mg/Ml, 10 Ml annual periodical maintenance , Calcium Phosphate Syrup, 200Ml , Calcium Salts 500 Mg+ Vitamin D3 250 Iu Tablet , Calcium Syrup Each 5 Ml Contains Calcium 250Mg, Vitamin D3 125 Iu , Capecitabine Tablet 1000 Mg , Capecitabine Tablet 500 Mg , Carbamazepine Oral Solution 100Mg/5Ml, 30 Ml Bottle , Carbamazepine Tablet 200 Mg , Carbamazepine Tablet 400 Mg , Carbimazole Tablet 5 Mg , Carbimiazole 10 Mg Tablet , Carboplatin Injection 150 Mg, 10 Mg/Ml Vial , Carboplatin Injection 450 Mg, 10Mg/Ml Vial , Carboprost Injection 25 Mg/Ml , 250 Mcg, 1Ml , Carfilzomib Injection 60 Mg , Cariprazine Tablet 1.5 Mg , Carpinol Inj. 0.5% , Carvedilol 3.125 Mg Tablet , Cefadroxil Oral Solution 125 Mg/ 5 Ml, 30 Ml , Cefepime 2 Gm + Tazobactom 250Mg Inj. , Cefixime 100 Mg Tablet , Cefixime Syrup 50 Mg/ 5 Ml, 30 Ml , Cefixime Tablet 200 Mg , Cefoperazone + Sulbactam (1G+1G) Injection , Cefotaxime Injection 1 Gm , Cefotaxime Injection 250 Mg , Cefotaxime Injection 500 Mg , Ceftazidime 1 Gm Injection , Ceftazidime 250Mg , Ceftriaxone + Salbuctam Injection (1Gm + 0.5Gm) , Ceftriaxone Injection 1 G Vial , Ceftriaxone Injection 250 Mg , Cetrimide Solution 20% concrete For Dilution 500Ml , Cetrizine Hydrochloride 10 Mg Tablet , Cetrizine Syrup 5 Mg/5Ml, 60 Ml , Chlordiazepoxide 10 Mg Tablet , Chlordiazepoxide 25 Mg Tablet , Chlorhexidine Mouth Wash Solution 100 Ml, 0.2% W/V , Chlorhexidine Solution 5% concrete For Dilution 5 Ltr , Chlorhexidine Solution 5% concrete For Dilution 500Ml , Chloroquine Phosphate Injection 40 Mg/Ml , Chloroquine Phosphate Oral Solution 50 Mg/ 5 Ml, 50Ml Bottle , Chloroquine Phosphate Tablet 250 Mg Equivalent To 155Mg Chloroquine Base , Chlorpheniramine Tablet 4 Mg , Chlorpromazine (Hydrochloride) Tablet 100 Mg , Chlorthlidone 12.5 Mg Tablet , Chlorthlidone 6.25Mg Tablet , Chymotrypsin+ Trypsin (1:6 ) Tablet 100K Au , Cilnidipine 10Mg Tablet , Cinnarizine Tablet 25 Mg , Ciprofloxacin (0.3% W/V) + Dexamethasone (0.1% W/V) Ear Drops, 10 Ml , Ciprofloxacin Eye Drop 0.3%, 10Ml , Ciprofloxacin Eye Ointment 0.3%, 5 Gm , Ciprofloxacin Injection Iv 2Mg/ Ml, 100 Ml , Ciprofloxacin Tablet 250 Mg , Ciprofloxacin Tablet 500 Mg , Cisplatin Injection 10 Mg , Cisplatin Injection 50 Mg, 1 Mg/Ml Vial , Citicoline Tablet 500 Mg , Clarithromycin 500 Mg Tablet , Clindamycin Gel 1% W/W, 10 Gm , Clinidipine Tablet 10 Mg , Clobazam Capsule 10 Mg , Clobetasol + Gentamycin Ointment 0.05% + 0.1 %, 15 Gm , Clobetasol + Salicylic Acid Cream 20 Gm , Clobetasol Cream 10Gm (0.05%) , Clobetasol+Saliyltic Acid Cream 10Gm , Clobetasone Butyrate + Miconazole Cream , Clofazimine 100 Mg Tablet , Clofazimine 50 Mg Tablet , Clomifene Citrate Tablet 50 Mg , Clonazepam 0.25 Mg Tablet , Clonazepam Tablet 0.5 Mg , Clonazepam Tablet 1 Mg , Clonidine 0.1 Mg Tablet , Clonidine 100Mcg Tab. , Clopidogrel Tablet 75 Mg , Clotrimazole +Beclomethasone 10Gm Cream , Clotrimazole 1% W/V + Lignocaine Hydrochloride 2% W/V Ear Drops, 5Ml , Clotrimazole Cream 2 %, 15Gm , Clotrimazole Ear Drops 1% W/V, 5Ml , Clotrimazole Mouth Paint 1% W/V, 15 Ml , Clotrimazole Pessaries 200 Mg , Clotrimazole200mg + Clindamycin 100 Mg Pessaries , Clotrimazole Powder 75 Gm , Cloxacillin Capsule 500 Mg , Clozapine 100 Mg Tablet , Clozapine 25 Mg Tablet , Clozapine 50 Mg Tablet , Coal Tar Solution 5%, 100Ml , Coconut Oil 100Ml , Codeine Phosphate 10Mg +C.P.M. 4Mg Per 5Ml,100Ml , Colistin Lyophilized Powder 4.5 Million I U Per Vial Injection , Collagen Membrane-Sterile Bioresorbable Gtr Collagen Membrane Isi/Iso/Ce Marked , Colostrum 500Mg Cap. , Combination Of Clinidine Bromide 2.5 Mg +Chlordiazepoxide 5.0 Mg+Dicyclomine 10.0 Mg (Normaxin Equivalent) Tablet , Conjugated Estrogen Tablet 0.625Mg , Cotrimazole 1 % + Betamethasone 0.0025% Lotion 15 Ml , Cotrimoxazole (Sulfamethoxazole + Trimethoprim) Tablet 800 Mg + 160 Mg , Co-Trimoxazole [Sulphamethoxazole (A) + Trimethoprim (B)] Oral Liquid 200 Mg (A) + 40 Mg (B)/5 Ml , Cough Expectorent (Salbutamol+Bromhexine ) Syrup 2 Mg +4 Mg, 100 Ml , Cough Expectorent (Salbutamol+Bromhexine ) Syrup 2 Mg +4 Mg, 60 Ml , Cough Syrup Ambroxol-15 Mg + Terbutaline Sulphate-1.5 Mg + Guaiphenesin-50 Mg/ 5 Ml 100 Ml , Cough Syrup Diphehydramine 14 Mg + Ammonium Chloride 135 Mg + Sodium Citrate 57 Mg + Menthol 0.9 Mg/5 Ml 100 Ml Bottle , Crotamiton Cream 20Gm , Cycloserine 250 Mg. Tablet , Cycloserine 500 Mg. Tablet , Cyclopentolate Hcl Eye Drops 1% W/V , 5Ml , Cyclophosphamide Injection 1000Mg, 1.33Mg/Ml Vial , Cyclophosphamide Injection 500Mg, 10Mg/Ml Vial , Cyclophosphamide Tablet 50 Mg , Cyproheptadine Tablet 4 Mg , Dacarbazine Injection 200 Mg, 10Mg/Ml Vial , Dacarbazine Injection 500 Mg , Daclatasvir 30 Mg Tablet , Daclatasvir 60 Mg Tablet , Darifenacin Tablet 7.5 Mg , Deferasirox Tablet 500 Mg , Deferasirox Tablet 250 Mg , Deferiprone Tablet 500 Mg , Deferoxamine Mesylate 2 Grams Per Injection , Degaralix Injection 240 Mg , Desferrioxamine Injection 500 Mg , Desvenlafaxine Tablet 50 Mg , Dexamethasone 6 Mg Tablet(Covid) 6 Mg , Dexamethasone Injection 4Mg/Ml, 2 Ml Ampoule , Dexamethasone Tablet 0.5 Mg , Dexamethasone Tablet 4 Mg , Dexamethasone Tablet 8 Mg , Diacerein 50 Mg + Glucosamine Sulphate 500 Mg Tablet , Diazepam Injection 5 Mg/Ml, 2 Ml Ampoule , Diclofenac (Sodium) Injection 25 Mg/Ml ,3Ml Amp. , Diclofenac + Paracetamol Tablet 50Mg+325Mg , Diclofenac 50Mg + Chlorzoxazone500mg + Paracetamol 250 Mg Tablet , Diclofenac Gel 1%, 30 Gm Tube , Diclofenac Injection 75 Mg/Ml ,1Ml Amp. (Intravenous) , Diclofenac Sodium Gastro-Resistant Tablet 50 Mg , Diclofenac Supositories 50 Mg , Diclofenac Spray 30Ml , Diclofenac Spray 100Ml , Dicyclomine 10 Mg+Mefenamic Acid 250 Mg Tablet , Dicyclomine 20 Mg+Mefenamic Acid 500 Mg Tablet , Dicyclomine Injection 2 Ml Ampule , Dicyclomine Oral Solution 10Mg/5Ml , Dicyclomine Tablet 10 Mg , Dienogest Tablet 2 Mg , Digestive Enzymes Capsule , Digoxin Tablet 0.25 Mg , Diltiazem Injection 5 Mg/Ml, 5Ml , Diltiazem Tablet 30 Mg , Dinoprostone Gel 0.5 Mg, 3 Gm , Disodium Hydrogen Citrate Oral Solution 1.38 Gm/ 5 Ml, 100 Ml , Distilled Water/Sterile Water 10Ml. , Distilled Water/Sterile Water 5Ml , Disulfiram Tablet 250 Mg , Disulfiram Tablet 500 Mg , Divalproex Sodium Tablet 500 Mg , Dns ( Sodium Chloride And Dextrose, Each 100 Ml Contains Dextrose 5 Gm, Nacl 0.9 G) 500Ml (Ffs Techonology) , Dobutamine Injection 250 Mg/5 Ml , Docitaxel Injection 120 Mg, 20Mg/ 0.5 Ml Vial , Dolutegravir Tablet 50 Mg , Domperidone Oral Solution 1 Mg/ Ml, 30Ml , Domperidone Tablet 10 Mg , Donepezil Injection 10 Mg , Donepezil Tablet 10 Mg , Donepezil Tablet 5 Mg , Dopamine Injection 40 Mg/ Ml In 5Ml Ampoule , Dothiepin Tablet 25 Mg , Dothiepin Tablet 75 Mg , Doxophylline 400 Mg Tablet , Doxorubicin Injection 10 Mg, 10Mg/Ml Vial , Doxorubicin Injection 50 Mg, 10Mg/Ml Vial , Doxycycline Capsules 100 Mg , Doxylamine Tablet 10 Mg , Drotaverine 40 Mg Tablet , Drotaverine 80 Mg + Mefenimic Acid 500 Mg Tablet , Drotaverine Injection 40 Mg/ 2 Ml , Drotaverine Tablet 80 Mg , Duloxetine Capsule 20 Mg , Duloxetine Tablet 30 Mg , Ecg Jelly 200 Ml Bottle , Elemental Iron 60 Mg +Folic Acid 500 Mcg, Sugar Coated And Red Color Tablet , Empagliflozin Tablet 10 Mg , Enema , Enoxaparin 40 Mg Inj. , Enoxaparin 60 Mg Inj. , Entacavir 0.5 Mg Tablet , Entecavir 1 Mg Tablet , Epirubicin Injection 10 Mg, 2Mg/Ml Vial , Epirubicin Injection 50 Mg, 2Mg/Ml Vial , Erlotinib Tablet 100 Mg , Erythromycin Syrup 125 Mg/5 Ml, 60 Ml , Erythromycin Tablet 250 Mg , Erythropoietin Injection 40000 Units/Ml, Single Dose 1 Ml Vial , Escitalopram Tablet 10 Mg , Estrogens Cream 0.625 Mg , Ethambutol Tablet 100 Mg , Ethambutol Tablet 400 Mg , Ethambutol Tablet 800 Mg , Ethamsylate Injection 250 Mg/2 Ml , Ethamsylate Tablet 250 Mg , Ethamsylate Tablet 500 Mg , Ethionamide 250 Mg Tablet , Ethionamide 500 Mg Tablet , Ethinyestradiol Tablet 5 Mcg , Etizolam Tablet 0.50 Mg , Etophylline + Theophylline Injection 169.4 Mg + 56.6 Mg/2 Ml , Etophylline + Theophylline Tablet 231 Mg + 69 Mg (Sr) , Etoposide Capsule 50 Mg , Etoposide Injection 100Mg, 20Mg/Ml Vial , Etoricoxib Tablet 90 Mg , Exemestene Tablet 1 Mg , Favipiravir(Covid) 400 Mg , Febuxostat 40 Mg Tablet , Fentanyl Injection 50 Mcg/Ml, 2Ml Ampoule , Ferrous (Iron Sucrose) Injection 20 Mg/Ml, 5 Ml Amp. , Ferrous Salt + Folic Acid(Ifa Wifs) Tablet(Enteric Coated) Equivalent To 100 Mg Iron + 500 Mcg Folic Acid (Blue) , Ferrous Sulpahte + Folic Acid Syrup 100 Mg + 0.5 Mg/ 5 Ml, 50 Ml Bottle, Ropp Cap Bottle With Inert Liner & Bottle To Be Provided With A Dispenser To Dispense To 1 Ml Each Time And Packed In A Mono Carton , Fevipiravir 200Mg Tablet , Fexofenadine 120 Mg Tablet , Fexofenadine 180 Mg Tablet , Filgrastim Injection 300Mcg, 300Mcg/0.5 Ml Prefilled Syringe , 3 Fdc Tablet (Each Film Cated Tablet Contains Rifampicin 150 Mg+ Isoniazid 75 Mg+ Ethambutol 275 Mg) Fixed Dose Combination For Tb , 4 Fdc Tablet (Each Film Cated Tablet Contains Rifampicin 150 Mg+ Isoniazid 75 Mg+ Ethambutol 275 Mg + Pyrazinamide 400Mg) Fixed Dose Combination For Tb , Flouromethalone 0.1% W/V Eye Drops 5Ml , Fluconazole Capsule/Tablet 150 Mg , Fluconazole Capsule/Tablet 200 Mg , Fluconazole Injection 200 Mg/ 100 Ml , Flunarazine Tablet 10 Mg , Fluoxetine Capsule 20 Mg , Fluphenazine Injection 25 Mg, 1 Ml Ampoule , Flurbiprofen Sod. Eye Drops 0.03%W/V ,10Ml , Fluticasone Cream 0.01%, 10Gm , Fluticasone Furoate Nasal Spray , Fluvoxamine 150 Mg Tablet , Folic Acid Tablet 5Mg , Formaldehyde Solution 400Ml , Formalin Tablet , Formocresol Formalin, Cresol Glycerin ,Formocresol Formalin Bp 20% V/V , Cresol Ip 32% V/V , Glycerin Ip Qs, 20Ml , Framycetin Cream 1%, 30 Gm Tube , Furosemide Injection 10 Mg/Ml, 2Ml Ampoule , Furosemide Tablet 40 Mg , Fusidic Acid Cream 2 %, 10 Gm , Gabapentin + Nortriptyline (400/10Mg) Tablet , Geftinib Tablet 250 Mg , Gemcitabine Injection 200Mg, 100Mg/Ml Vial , Gentamycin Injection 40 Mg/ Ml, 2 Ml Vial , Gentian Violet (Methylrosanilinium Chloride Paint Preparation Aqueous Solution 0.5%W/V), 50 Ml Dark Bottle , Gentian Violet (Methylrosanilinium Chloride Paint Preparation Aqueous Solution 0.5%W/V), 15 Ml Dark Bottle , Glimipride Tablet 1 Mg , Glimipride Tablet 2 Mg , Glucose With Sodium Chloride/Saline Injection 5% Glucose + 0.9% Sodium Chloride, 500Ml (Ffs Technology) , Glucose/Dextrose Injection 10% Isotonic 500 Ml(Ffs Technology) , Glucose/Dextrose Injection 25%, 100 Ml(Ffs Technology) , Glucose/Dextrose Injection 5% Isotonic 500 Ml(Ffs Technology) , Glycerine Trinitrate Injection (Nitro Glycerine) 5 Mg/ Ml , Glyceryl Trinitrate ( Niroglycerine) Injection 5 Mg/Ml, 5 Ml Ampule , Glyceryl Trinitrate (Sublingual) Tablet 500 Micrograms , Glycopyrolate Injection 0.2 Mg/Ml, 1 Ml Ampoule , Glycopyrronium +Formoterol Fumarate Rota Caps , Goserline Injection 10.8 Mg , Granisetron Injection 1 Mg , Granisetron Injection 3 Mg , Griseofulvin Tablet 250 Mg , Haloperidol Injection 5 Mg/ Ml , Haloperidol Injection Long Acting 50 Mg , Haloperidol Tablet 5 Mg , Halothane Inhalation 250 Ml Bottle , Hcg (2000 Iu) Inj. , Hcg (5000 Iu) Inj. , Heparin Injection (5000 Iu/Ml) 5Ml, 1% , Hepatitis B Immunoglobulin Injection 100 Iu/ 1Ml. , Hepatitis B Vaccine (R Dna) I.P. 0.5Ml Inj, 10Mcg/0.5Ml , Hepatitis B Vaccine (R Dna) I.P. 0.5Ml Inj, 5Mcg/0.5Ml , Homatropine Eye Drops 1%, 5Ml , Homatropine Eye Drops 2%, 5Ml , Human Albumin 20% Sol. Ip, 100Ml For I/V Use , Hyaluronidase Injection 1500 Iu/Ml , Hyaluronidase Injection 1500 Iu/Ml (Appasamy) , Hydrochlorothizide 12.5 Mg Tablet , Hydrocortisone ( Sodium Sucinate Powder) Injection 100 Mg Vial, With 2 Ml Distilled Water For Reconstitution , Hydrogen Peroxide Solution 6%, 400 Ml Bottle , Hydroprogesterone 250 Mg Inj. , Hydroprogesterone 500 Mg Inj. , Hydroquinone 2%/4% + Tretinoin 0.025 % +Fluocinolone Skin Cream, 15 Gm Tube , Hydroquinone 2.0% W/W + Tretinoin 0.025% W/W + Mometasone Furoate 0.1% W/W In A Cream Base Q.S, 15 Gm Tube , Hydroquinone 20Gm Cream , Hydroxy Urea Cap 500Mg , Hydroxychloroquine 200 Mg Tablet , Hydroxychloroquine 400 Mg Tablet , Hydroxycobalamin Injection 1 Mg/ Ml , Hydroxypropyl Mehtylcellulose Injection 2 %, 5Ml , Hydroxypropyl Mehtylcellulose Injection 2 %, 5Ml (Appasamy) , Hydroxyzine Tablet 10 Mg , Hynidase / Omnidase Inj., 1500 Iu, Dry Vial Of Powder Not For Iv Use , Hyoscine Butyl Bromide Injection 20 Mg/ Ml , Hyoscine Butyl Bromide Tablet 10 Mg , Ibuprofen Oral Solution 100 Mg/5 Ml. 60 Ml Bottle , Ibuprofen Tablet 200Mg , Ibuprofen Tablet 400 Mg , Ibuprofen Tablet 400 Mg +Paracetamol 325 Mg Tablet , Ichthammol Glycerine Solution 10 Ml Vial , Imatinib Tablet 400 Mg , Imipenem And Cilastatin Injection (500 Mg+500 Mg) , Imipenem Injection 500Mg , Imipramine 75 Mg Tablet , Imipramine Tablet 25 Mg , Indomethacin 25 Mg Tab , Insulin (Soluble) Injection 40 Iu/Ml In 10 Ml Vial , Intracameral Lignocaine 1% 2Ml Inj , Intracameral Moxifloxacin Inj. (Opthalmic Sol.) , Intracameral Phenylephrine 0.5Ml Solution For Pupil Cataract Surgery , Intravenous Immunoglobulin(Ivig) 10 Gm,100 Ml Bottle , Iohexol Injection 300 Mg , Ipratropium Respirator Solution For Use In Nebulizer 250Mcg/ 1Ml, 2Ml , Iron And Folic Acid Tablet ( Wifs Junior ) Containing Dried Ferrous Sulphate Ip Equivalent To Ferrous Iron 45Mgm And Folic Acid Ip 0.4Mg Per Tablet. Tablet Are Sugar Coated And Pink Coloured Tablets With Only Edible Colours Used Tablet Ferrous Iron 45Mgm And Folic Acid Ip 0.4Mg Per Tablet , Iron Sucrose 100 Mg/Ferric Carboxymaltose Ml , 10 Ml Inj. , Isoflurane Inhalation 100 Ml Vial , Isoniazid Tablet 100Mg , Isoniazid Tablet 300Mg , Isophosphamide Injection 200Mg, 100Mg/Ml Vial , Isophosphamide Injection 200Mg, 100Mg/Ml Vial , Isosorbide Dinitrate Tablet (Sublingual) 5 Mg , Isosorbide Mononitrate Tablet 20 Mg (Xr) , Isosorbide Mononitrate Tablet 30 Mg (Sr) , Isotretinoin Capsule 20 Mg , Isoxsuprine Injection 5 Mg/ Ml, 2Ml , Isoxsuprine Tablet 10 Mg , Ispaghula Granules/ Husk/ Powder Sachet 3.5 Gm , Ispaghula Granules/ Husk/ Powder 100Gm. Gm , Itraconazole 100 Mg Tablet , Itraconazole 200 Mg Tablet , Ivermectin Tablet 12 Mg , Ivermectin Tablet 6 Mg , Ketaconazole Lotion 2% W/V, 50 Ml , Ketamine (As Hydrochloride) Injection 50 Mg /Ml,10 Ml Vial , Ketoconazole 200 Mg Tablet , Ketoconazole Sampoo 100Ml , Kojic Acid Cream 2 %, 15Gm , Labetalol Injection 20 Mg, 5Mg/Ml, 4 Ml Amopule , Labetalol Tablet 100 Mg , Lacosamide Tablet 100 Mg , Lactulose Solution 10 Mg/15 Ml, 60Ml , Lantus Insulin (Insulin Glargine 100 Units/Ml) , Latanoprost Ear Drops 0.005 % W/V, 5 Ml , Lenalidomide Tablet 10 Mg , Letrozole Tablet 2.5 Mg , Leucovorin Injection 50 Mg/5Ml , Levamasole Tablet 150 Mg , Levamasole Tablet 50 Mg , Levetiracetam Tablet 500 Mg , Levitiracetam Oral Solution 500Mg/5Ml, 100Ml , Levitracetam 500Mg/5Ml Inj., 5Ml Inj , Levocetrizine 5Mg + Montekulast 10 Mg Tablet , Levocetrizine Tablet 5 Mg , Levodopa + Carbidopa Tablet 100 Mg + 10 Mg , Levodopa Tablet 100Mg , Levofloxacin Eye Drop 5Ml , Levofloxacin Tablet 250Mg , Levofloxacin Tablet 500 Mg , Levosalbutamol (0.63Mg) Respules 2.5Ml , Levosalbutamol 1.25Mg + Ipratropium, 500Mcg, Respules , Levosulpride (Sr) 75 Mg + Rabeprazole (Ec) 20 Mg Capsule , Levothyroxine 100 Mcg Tablet , Lidocaine (2% W/V) + Clotrimazole 1% W/V + Beclomethasone 0.025% W/V + Ofloxacin (0.3% W/V) 5Ml Ear Drops , Lidocaine 10% Spray, 50Ml , Lidocaine 30Ml Inj. , Lidocaine Topical Spray (15% W/W), 100 Ml , Lignocaine 1% Ointment, 30Gm , Lignocaine 4% Spray Topical Solution 30Ml , Lignocaine Hydrochloride And Adrenaline Bitartarate Injection 20Mg/Ml And 0.01Mg/Ml Adrenaline, 30 Ml Vial , Lignocaine Injection 2%, 30 Ml Vial , Lignocaine Jelly 2% W/V ( With Seprate Nosal), 30Gm Tube , Linezolid Inj. 600Mg , Linezolid Tablet 600 Mg , Lithium Carbonate Tablet 300 Mg , Lithium Tablet special repair 400 Mg , Lmw Heparin Injection 60Mg/0.6Ml For Sc Use Prefilled Syringe , Loperamide 2Mg Tab. , Lorazepam Injection 4Mg, 2Ml , Lorazepam Tablet 1 Mg , Lorazepam Tablet 2 Mg , Losartan + Hydrochlorothiazide Tablet (50 Mg + 12.5 Mg) , Luliconazole Cream 1 % W/W, 30 Gm , Luperolide Acetate Injection 22.5 Mg , Magnesium Sulphate + Sullfacetamide (Sumag ) 75Gm Ointment , Magnesium Sulphate 58%, Urea 1%, Sulphacetamide Sodium 2.5%, Proflavine 0.1% (In Glycerine Base) Ointment 75Gm , Magnesium Sulphate Injection 1 Gm /2Ml (50%W/V), 2 Ml Ampoule , Magnesium Sulphate Injection 2.5 Gm /5Ml(50%W/V), 5 Ml Ampoule , Magnesium Sulphate Injection 500Mg/Ml,1 Ml Ampoule , Malathion 50% Ec, 1 Ltr , Malathion Technical 95%, 25 Kg , Mannitol Injectable Solution 20 %,100 Ml (Ffs Technology) , Mdi-Formoterol+Budesonide Inhaler , Medroxyprogesterone Acetate Injection Ip (Dmpa ) 25 X 1X 1Ml (Contraceptive Injection For Im Use Only) , Medroxyprogesterone Tablet 10 Mg , Melatonin Tablet 3 Mg , Memantine Tablet 5 Mg , Mephentermine Injection 30 Mg/Ml, 10 Ml Amp. , Meropenum Injection 125 Mg , Meropenum Injection 250 Mg , Meropenum Injection 500 Mg , Mesalamine 800 Mg Tablet , Mesna Injection 400 Mg , Metformin special repair 1 Gm Tablet , Metformin special repair 500 Mg Tablet , Metformin Tablet 1 Gm , Metformin Tablet 500 Mg , Methotrexate Injection 50 Mg, 2Ml Inj , Methotrexate Tablet 2.5 Mg , Methotrexate Tablet 50 Mg , Methoxsalen Tablet 10 Mg , Methyl Cobalamine 1500 Mcg Inj. , Methyl Cobalamine 500 Mcg Inj. , Methyl Ergometrine Injection 200 Mcg In 1 Ml Ampoule , Methyl Ergometrine Tablet 125 Mcg , Methyl Prednisolone Injection 1Gm, 1 Gm Vial With Diluent , Methyl Prednisolone Injection 80Mg , Methylcobalamin Tablet 1500 Mcg , Methylcobalamin Tablet 750 Mcg , Methylcobalamine + Pregabaline (1500+75) Tablet , Methyldopa Tablet 250 Mg , Methyldopa Tablet 500 Mg , Methylene Blue 25 Gm , Methylphenidate Tablet 5 Mg , Methylrosanilinium Chloride (Gentian Violet) Topial Preparation 0.25 % To 2% , Metoclopramide Injection 5 Mg/Ml, 2 Ml Ampoule , Metoclopramide Tablet 10 Mg , Metoprolol 5 Ml Injection , Metoprolol Tablet (Sr) 50 Mg , Metoprolol Xl 25 Mg Tablet , Metronidazole Injection 500 Mg/ 100Ml (Ffs Technology) , Metronidazole Oral Solution 200 Mg/5 Ml, 60Ml , Metronidazole Tablet 200 Mg , Metronidazole Tablet 400 Mg , Micronized Progesterone Tablet 200 Mg , Midazolam Injection 1 Mg/Ml, 5 Ml Vial , Mifepristone Tablet 200 Mg , Mifepristone Tablet 25 Mg , Minoxidil Solution 5% , Mirabegron Tablet 50 Mg , Mirtazapine Tablet 15 Mg , Mirtazepine 7.5 Mg Tablet , Misoprostol Tablet 200 Mcg , Misoprostol Tablet 25Mg , Mitomycin Injection 40 Mg , Mometasone + Terbinafine (0.1% W/W + 1.0 % W/W) 15 Gm Cream , Mometasone Furoate Cream 0.1 % W/W, 30Gm , Monteleukast Tablet 5 Mg , Montelucast 10Mg + Fexofenadine 120Mg Tablet , Morphine Injection 10 Mg/Ml, 1 Ml Ampoule , Morphine Tablet 10 Mg , Morphine Tablet 20 Mg , Morphine Tablet 30 Mg special repair , Mouth Ulcer Gel (Choline Salicylate Sodium 9% W/V, Benzalkonium Chloride 0.01% W/W) , Moxifloxacin 400 Mg. Tablet , Moxifloxacin 0.5% Eye Drop ,5Ml , Moxifloxacin 0.5% W/V+ Ketorolac 0.5% W/V Eye Drop ,5Ml , Moxifloxacin 0.5% W/V+ Prednisolone 1% W/V Eye Drop ,5Ml , Moxinidine 0.2 Mg Tablet , Multi Electrolyte Injection (Isolyte -P) 500Ml , Multi Vitamin Injection 10 Ml , Multi Vitamin Injection 2 Ml , Multi Vitamin Syrup With Trace Elements, 200Ml (Ffs Technology) , Multivitamin Drops, 15 Ml , Mupirocin Cream 5Gm, 2% W/W , Mupirocin Ointment 2% W/W, 5 Gm Tube , N-Acetylcysteine 600 Mg Tablet , Naloxone Injection 400 Mcg/Ml, 1Ml Ampoule , Naltrexone Tablet 50 Mg , Nandrolone Decanoate 50Mg Inj. , Naocl 5.25% Solution Isi/ Iso/Ce/Marked. , Naproxen 500Mg + Domperidone 10Mg Cap./Tab , Natamycin Eye Drops 2%, 5 Ml , Nebivalol Tablet 5 Mg , Neostigmine Injection 500 Mcg/ Ml , Netilmicin Injection 25Mg/Ml , Nicorandil 10 Mg Tablet , Nicorandil 5 Mg Tablet , Nicotin Chewgum 2 Mg , Nicotin Chewgum 4 Mg , Nicotine Pastilles 2 Mg , Nicotine Pastilles 4 Mg , Nicotine Patches , Nifedipine 0.3% W/W + Lidocaine 1.5% W/W Ointment, 30 Gm , Nifedipine Capsule(Sublingual) 5 Mg , Nifedipine Tablet Ip Sr/Er 10 Mg , Nikethamide Inj. 250Mg/1Ml , Nitrofurantoin Tablet 100 Mg , Nitroglycerin 2.6 Mg Tablet , Nitroglycerin 6.4 Mg Tablet , Nitroglycerin Inj. 25Mg/5Ml , Nitrous Oxide Inhalation , Nor Adernaline Injection 4Mg/2Ml , Norethisterone Tablet 5 Mg , Norfloxacin 400Mg Tab , Normal Saline (Sodium Chloride) Injection 0.9% Isotonic, 500 Ml (Ffs Technology) , Normal Saline (Sodium Chloride) Injection Solution 0.9% Isotonic, 100Ml(Ffs Technology) , Normal Saline 3% Injection 100Ml , Octreotide Injection 100 Mcg/Ml, Single Dose 1 Ml Vial , Ofloxacin + Dexamethasone Eye Drops 10 Ml , Ofloxacin 200Mg + Ornidazole 500Mg Inj.,100 Ml , Ofloxacin Tablet 200 Mg , Olanzapine 5 Mg Tablet , Olanzapine Injection 10Mg/Vial , Olanzapine Injection 210 Mg Long Acting , Olanzapine Injection 300 Mg Long Acting , Olanzapine Injection 405 Mg , Olanzapine Tablet 10 Mg , Olanzapine Tablet 20 Mg , Olmesartan 20 Mg + Amlodipine 5 Mg + Hydrochlorothiazide 12.5 Tablet , Olmesartan 20 Mg Tablet , Olpatadine 0.1%W/V Eye Drop 5 Ml , Omeprazole Capsule 20 Mg , Ondansetron Injection 2Mg/Ml ,2Ml Ampoule , Ondansetron Oral Liquid 2 Mg/ 5 Ml , Ondansetron Tablet 8 Mg , Oral Caffiene Citrate Sol. 20Mg/Ml, 3Ml , Oral Glucose 75 Gm , Oral Rehydration Salts Powder For 1000 Ml Solution , Oral Rehydration Salts Powder For 200 Ml Solution , Oseltamivir Syrup (Each 1 Ml Reconstituted Suspension Contain 12 Mg Oseltamivir, 75 Ml Bottle) Syrup , Oseltamivir Tablet 30 Mg , Oseltamivir Tablet 45 Mg , Oseltamivir Tablet 75 Mg , Oxaliplatin Injection 100Mg, 5Mg/Ml Vial , Oxaliplatin Injection 50Mg, 5Mg/Ml Vial , Oxygen (Medicinal Gas) Inhalation Per Kg , Oxytocin Injection 5 Iu In 1 Ml Ampoule , Paclitaxel Injection 260Mg, 10Mg/1.67 Ml Vial , Pantoprazole + Domperidone special repair (40Mg+30Mg) Capsule , Pantoprazole Injection 40 Mg , Paracetamol Drops 150Mg/Ml, 10 Ml Vial With Marked Dropper , Paracetamol Infusion 100 Mg/ 5 Ml, 100Ml , Paracetamol Injection 150 Mg/Ml, 2 Ml Amp. , Paracetamol Peadiatric Syrup 125Mg/ 5Ml, 60 Ml Bottle , Paracetamol Tablet 500 Mg , Paracetamol Tablet 650 Mg , Paroxetine (Cr) Tablet 25 Mg , Paroxetine Tablet (Cr) 12.5 Mg , Pazopanib Tablet 200 Mg , Peg Filgrastim Injection 6 Mg , Pemetrexed Injection 500Mg, 25Mg/Ml Vial , Pentazocine Injection 30 Mg/ Ml, 1 Ml Ampoule , Perampenel 2 Mg , Permethrin Cream 5% 30 Gm , Permethrin Lotion 5% 50 Ml , Pethidine Injection 50 Mg/Ml, 1Ml Ampoule , Pheniramine Maleate Injection 22.75 Mg/Ml, 2 Ml , Phenobarbitone Injection 200 Mg/ Ml , Phenobarbitone Oral Solution 20 Mg/ 5 Ml,60 Ml Bottle , Phenobarbitone Tablet 30 Mg , Phenobarbitone Tablet 60 Mg , Phenylephrine 10Mg + Pcm 325Mg +Cetrizine 5Mg Tablet (Anticold Tablet) , Phenytoin (Sodium) Injection 100Mg, 2Ml Amp. , Phenytoin Oral Solution 25 Mg/Ml, 100 Ml Glass Bottle , Phenytoin Tablet 100 Mg , Phenytoin Tablet 300 Mg , Phytomenadion Injection 1 Mg/0.5 Ml Water Based Single Dose (Vitamin-K1) , Pilocarpine Hcl 2% ,5Ml Eye Drops , Pilocarpine 1Ml Injection , Pioglitazone 30Mg Tab. , Pioglitazone 50 Mg Tablet , Piperacillin 1 Gm + Tazobactum 0.12Gm Injection , Pipracillin + Tazobactoam 4.5 Gm I/V Injection , Piracetam 400Mg Tab. , Piracetam 800Mg Tab. , Plasma Volume Expender Injection 500 Ml , Podophylline Resin Topical Solution 25% , 10 Ml Bottle , Posaconazole 100 Mg Tablet , Potassium Chloride (Solution) Injectable 15% (150Mg/Ml) , Potassium Chloride Oral Liquid 500 Mg/5 Ml, 100Ml , Potassium Permanganate Crystal 100 Gm(Kmno4) , Potassium Permanganate Crystal 20 Gm(Kmno4) , Povidine Iodine 10% ,500 Ml Solution , Povidine Iodine 5% Eye Drops, 5Ml , Povidine Iodine Ointment 5%,15 Gm , Povidine Iodine Scrub 7.5%, 500 Ml , Povidine Iodine Solution 5% ,500 Ml , Pralidoxime (Pam) Injection 500 Mg, 20 Ml , Prazosin 5 Mg Tablet , Prednisolone Sod. Phosphate Eye Drop 1%, 5Ml , Prednisolone Tablet 10 Mg , Prednisolone Tablet 20 Mg , Pregabalin 75 Mg+ Methylcobalamin 750 Mcg Tablet , Pregabalin 75Mg Cap. , Pregablin 75Mg +Methylcobalmin 1500Mg +Nortriptylline 10Mg , Primaquine Tablet 15 Mg , Primaquine Tablet 2.5 Mg , Primaquine Tablet 7.5 Mg , Probiotic Capsule , Prochlorperazine Mouth Dissolving Tablet Flavored Base 5Mg , Promethazine Elixir Or Syrup 5 Mg/ 5 Ml,60Ml , Promethazine Injection 25 Mg/Ml, 2 Ml annual periodical maintenance , Propofol Injection 1% Vial(10Mg/Ml,10 Ml Vial) , Propranolol Tablet (Sr) 40 Mg , Propranolol Tablet 20 Mg , Prostadin 2 Ml annual periodical maintenance Injection , Protamine Sulphate (Heparin Antagonist) Injection 10 Mg/Ml, 5-Ml Ampoule , Purified Freeze - Dried Human Coagulation Factor Viii, Virus Inactivated Injection 250 Iu , Purified Freeze Dried Human Coagulation Factor Ix, Virus Inactivated / Anti Hemophillic Factor Ix Injection 500Iu , Pyrazinamide 500 Mg Tablet , Pyrazinamide 750 Mg Tablet , Pyrazinamide 1000 Mg Tablet , Pyridium Tablet 200 Mg , Pyridoxine Tablet 50 Mg , Pyridoxine Tablet 100 Mg , Quetiapine Tablet 50 Mg , Quetiapine Tablet special repair 100 Mg , Quinine Sulphate Injection 300 Mg/ Ml, 2Ml Ampoule , Quinine Sulphate Tablet 300 Mg , Rabeprazole +Domparidone Cap. Dsr , Ramipril Tablet 5 Mg , Ranitidine Injection 25 Mg/Ml, 2 Ml annual periodical maintenance , Ranitidine Syrup 75 Mg/5 Ml, 100Ml Bottle , Ranitidine Tablet 150 Mg , Ranolazine 500 Mg Tablet , Raybiotic-Ac Ear Drop (Beclomethasone +Chloramphenical+Clotimazole+Lignocaine) 5Ml Ear Drop , Recombinant Tissue Plasminogen Activator Injection Kit (18.1 Mg, 2 Single Use Diluent Vials For Reconstitution (10 Ml Sterile Water For Injection, 2 Sterile 10 Ml Syringes, 2 Sterile Dispensing Pins, 4 Sterile Needles, 2 Alcohol Swabs , Remdesivir Injection 100Mg , Respule Levosalbutamol 1.2Mg + Ipratropium 500Mcg Respule , Ribavirin 200 Mg Cap. , Rifampicin 150 Mg Capsule , Rifampicin 300 Mg Capsule , Rifampicin 450 Mg Capsule , Rifampicin 600 Mg Capsule , Rifapentine Tablet 300 Mg , Rifaximin 550 Mg Tablet , Ringer Lactate 500 Ml (Ffs Technology) , Ringer Lactate Injection 500Ml (Glass Bottle) , Risperidone Tablet 2 Mg , Risperidone Tablet 4 Mg , Rituximab Injection 500 Mg , Rosuvasatatin 10 Mg Tablet , Rosuvasatatin 20 Mg Tablet , Rosuvastatin 10 Mg+ Fenofibrates 160 Mg Tablet , Saccharomyces Boulardii 5 Cfu Sachets , Salbutamol Inhalation Mdi- 100 Microgram/ Dose , Salbutamol Nebulizer /Respirator Sol. 2.5Mg/2.5Ml , Salbutamol Oral Solution 2 Mg/5 Ml, 100Ml , Salbutamol Tablet 4 Mg , Salicylic Acid Ointment 6%, 15 Gm , Saline Nasal Drops 0.65%, 10Ml , Savlon Antisepic Solution / Liquid 100 Ml Bottle , Seasonal Influenza Quadrivalent/ Tetravalent Vaccine Single Dose , Sensorcaine Injection 0.5% 20 Ml , Serratiopeptidase 10Mg Tab. , Sertaconazole Cream 2% W/W, 15 Gm , Sertraline Tablet (Sr) 50 Mg , Sertraline Tablet 100 Mg , Sevelamer 800Mg Tablet , Sevoflurane Inhalation 250 Ml , Silodosin Tablet 8.0 Mg , Silver Sulfadiazine 250 Gm , Silver Sulfadiazine Cream 1%,30Gm , Simethicone+ Dill Oil + Fennel Oil Syrup, 15Ml , Sodium Bicarbonate Injection 7.5 % , 10 Ml Ampoule , Sodium Carboxymethyl Celloluse Eye Drop 0.5%W/V , 10Ml , Sodium Carboxymethyl Cellulose Eye Drops 0.5%W/V, 5Ml , Sodium Chloride Topical Eye Drop 6%W/V , 5Ml , Sodium Fusidate Skin 2% W/V Ointment 15Gm , Sodium Hylanuranate 1.8 % In 1 Ml Pfs ( (Isi/Iso/Ce Certified)) , Sodium Valproate Injection 100 Mg/Ml, 5Ml , Sodium Valproate Suspension 200 Mg/5 Ml, 100 Ml , Sodium Valproate/Valproic Acid (Sodium)Controlled Released Tablet 300 Mg , Sodium Valproate/Valproic Acid Enteric Coated Tablet 200 Mg , Sodium Valproate/Valproic Acid Enteric Coated Tablet 500 Mg , Sofosbuvir 400 Mg Tablet , Sofosbuvir 400 Mg Tablet + Ledipasvir 90 Mg Tablet , Sofosbuvir 400Mg+ Velpatasvir 100 Mg Tablet , Sorafenib Tablet 200 Mg , Sorbitrate (Iso-Sorbidnitrate Sublingual) 5 Mg Tablet , Spironolactone Tablet 25 Mg , Streptokinase Injection Powder 1500000 Iu , Succinyl Choline Injection 50 Mg/Ml, 10Ml , Sucralfate 1Gm With Oxetacain 10Mg/10Ml Suspension, 100 Ml Bottle , Sulfadoxine + Pyrimethamine Tablet 500 Mg + 25 Mg , Sulfasalazine Tablet 500 Mg , Sunitinib Tablet 50 Mg , Sunscreen Lotion Spf 26, 100 Ml , Surfactant- Survanta(Synthetic)(25 Mg/1Ml), Exosurf (Bovine) , Tacrolimus Ointment 0.03% W/W, 10 Gm , Tadalafil 10 Mg , Tamoxifen Citrate Tablet 10 Mg , Tamoxifen Citrate Tablet 20 Mg , Tamsulosin 0.4 Mg + Dutasteride 0.5 Mg Tablet , Tamsulosin Tablet 0.4 Mg , Telmisartan Tablet 40 Mg , Telmisartan Tablet 80 Mg , Temozolamide Tablet 100 Mg , Temozolamide Tablet 250 Mg , Temphos 50% Ec 5 Liter Pack , Tenecteplase Injection 20 Mg , Teneligliptin Film Coated Tablet 20 Mg , Tenofovir 300 Mg Od Tablet , Tenofovir 300 Mg+ Lamivudine 300 Mg Tablet , Terbinafine Tablet 250 Mg , Terlipressin 1 Mg Inj. , Tetanus Toxoid Injection 0.5 Ml Ampoule , Tetanus Toxoid Injection 5 Ml Vial , Thalidomide Tablet 100 Mg , Thiamine Injection 100 Mg/Ml, 2 Ml , Thiamine Tablet 100 Mg , Thiocolchicoside Capsule 4 Mg , Thiopentone Injection Powder 0.5 G , Thyroxine Tablet 100 Mcg , Thyroxine Tablet 125 Mcg , Thyroxine Tablet 150 Mcg , Thyroxine Tablet 25 Mcg , Thyroxine Tablet 50 Mcg , Thyroxine Tablet 75 Mcg , Timolol Eye Drops 0.5% ,5Ml , Tinidazole Tablet 500 Mg , Tizanidine Tablet 4Mg , Tobramycin Eye Drops 0.3% W/V, 5Ml , Tocilizumab Injection 400 Mg/20 Ml , Toperamate Tablet 50 Mg , Torasemide Tablet 10 Mg , Torasemide Tablet 20 Mg , Torsemide + Spironolactone 10/50 Mg Tablet , Tramadol Capsule 50 Mg , Tramadol Hydrochloride Capsule 100 Mg , Tramadol Injection 50 Mg/Ml, 2 Ml Ampoule , Tranexamic Acid 500 Mg + Mefenamic Acid 250 Mg Tablet , Tranexamic Acid Injection 500 Mg/5 Ml , Tranexamic Acid Tablet 500 Mg , Tranylcypromine Tablet 5 Mg , Trastuzumab Injection 150 Mg , Trastuzumab Injection 450 Mg , Tretinon Gel (0.05%) 20Gm , Triamcinolone Injection 40 Mg/Ml , Triancinolone Oral Paste/Gel (0.1%) , Tricholine Citrate 275Mg + Cyproheptadine Hcl 2Mg/5Ml Syrup, 200Ml , Trihexyphenidyl Tablet 2 Mg , Trihexyphenidyl Tablet 5 Mg , Trimetazidine 35 Mg Tablet , Tropciamide Eye Drops 5Ml , Tropicamide + Phenylepherine Eye Drops 0.8% + 5%, 5Ml , Tropicamide Eye Drops 1% Eye Drop 5Ml , Tropicamide+Phenylepherine(0.8%+5%) Eye Drop 5Ml , Tryptan Blue Dye 0.06% W/V, 1 Ml Vial , Ursodeoxycholic Acid Tablet 300 Mg , Valethamate Injection 8 Mg/Ml , Vancomycin Injection 500 Mg , Vareniciline 0.5Mg Tablet , Vareniciline 1 Mg Tablet , Vecuronium Injection 10Mg Vial , Venalafaxine Tablet 37.5 Mg , Venalafaxine Tablet 75 Mg , Verapamil Tablet 40 Mg , Vidagliptin 50Mg , Vinblastine Injection 10 Mg, 1Mg/Ml Vial , Vincristine Suphate Injection 1 Mg, 1Mg/Ml Vial , Vitamin A Oral Solution 100000 Iu/Ml, 100Ml Bottle , Vitamin D Tablet (Chewable) 60000Iu , Vitamin D3 Drops 400 Iu/Ml, 30 Ml , Vitamin-D3 60000 Iu Cap. , Voglibose 0.3 Mg + Metformin 500Mg+ Glimipride 1 Mg Tablet , Voglibose 0.3 Mg Tablet , Vortioxetine Tablet 10 Mg , Warfarin (Sodium) Inj Single Dose Vial , Warfarin (Sodium) Tablet 2 Mg , Wax Dissolving Ear Drops Paradichlorbenzene + Benzocain + Chlorbutol + Turpentine Oil 2 % + 2.7 % + 5 % + 15 %, 15 Ml Bottle , Weekly Iron Folic Acid Tablet Each Tablet Containing 60 Mg Elemental Iron+500 Mcg Folic Acid, Sugar Coated ,Blue Colour , Xylometazoline Nasal Drops 0.05 %, 10Ml , Xylometazoline Nasal Drops 0.1 %, 10Ml , Zinc (Sulphate) Dispersible Tablet 20 Mg , Zinc Oral Drops, 30Ml , Zinc Syrup 20 Mg/5Ml, 100Ml , Zolidronic Acid Injection 4 Mg , 4% Taper Gutta Percha Size 25 , 6% Taper Gutta Percha Size 25 , 6% Taper Gutta Percha Size 30 , 6% Taper Gutta Percha Size 35 , 6% Taper Gutta Percha Size 40 , Absorbent Point No.15-40, Isi/Iso/Ce Marked Packet Of 200 , Absorbent Point No.45-80, Isi/Iso/Ce Marked Packet Of 200 , Acrylic Teeth Cross Linked Anterior Set Of 12 Teeth Isi/Iso/Ce Marked , Acrylic Teeth Cross Linked Posterior Set Of 16 Teeth Isi/Iso/Ce Marked , Acrylic Teeth Cross Linked Teeth Set Of 28 Teeth Isi/Iso/Ce Marked , Acrylic Trimming Stone (Various Grit) Isi/Iso/Ce Marked , Acrylic Trimming Stone Isi/Iso/Ce Marked , Agar Isi/Iso/Ce Marked , Air Rotor Cartridges (Nsk) Standard Head Isi/Iso/Ce Marked , Air Rotor Cartridges (Nsk) Supertorque Isi/Iso/Ce Marked , Air Rotor Spray Isi/Iso/Ce Marked Bottle , Alginate Impression Material Isi/Iso/Ce Marked , Alu Wax Isi/Iso/Ce Marked , Amalgam Finishing Kit , Arch Bar Length 1 Feet Isi/Iso/Ce Marked , Articulating Paper Isi/Iso/Ce Marked (40-100 Microns) , B.P. Blade Size 11 Isi/Iso/Ce Marked , B.P. Blade Size 15 Isi/Iso/Ce Marked , B.P. Blade Size 23 Isi/Iso/Ce Marked , Beading Wax Isi/Iso/Ce Marked , Bioplast Sheets Proprietary Item 2 Mm Thickness Isi/Iso/Ce Marked , Bioplast Sheets Proprietary Item 3 Mm Thickness Isi/Iso/Ce Marked , Blue Elastic Separators ( Leone/ American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked , Bondable Buccal Tubes Upper And Lower Right And Left 1St Molars .022€ Mbt With Upper Triple And Lower Double Slot (Desires/ Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked , Bondable Buccal Tubes Upper And Lower Right And Left 2Nd Molars .022€ Mbt (Desires/ Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked , Bonding Agent For Composite 2 Bottle Self Etch System Isi/Iso/Ce Marked 4-6 Gm Or Equivalent In Ml , Bonding Agent For Composite One Bottle Total Etch System (Bottle With Primer +Adhesive) 4-6 Gm Or Equivalent In Ml. Isi/Iso/Ce Marked , Bone Graft Material For Dental Purpose Isi/Iso/Ce/Marked , Boxing Wax Isi/Iso/Ce Marked , Calcium Hydroxide Paste In Syringe Isi/Iso/Ce Marked , Calcium Hydroxide Two Paste System Isi/Iso/Ce Marked , Carborundum Disc (Assorted Size)Isi/Iso/Ce Marked , Cavity Varnish Isi/Iso/Ce Marked , Ceramic Finishing Kit , Chrome Cobalt Alloy Isi/Iso/Ce Marked , Collagen Membrane-Sterile Bioresorbable Gtr Collagen Membrane Isi/Iso/Ce Marked , Colourless O Rings (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked , Composite Finishing Kit - Disc Type With 180 To 240 Dics Of Different Grits ,Mandrel , Composite Finishing Kit With 12 To 24 Finishing Points Of Different Shapes , Composite Nanohybrid , Crimpable Hooks Isi/Iso/Ce Marked , Cu Niti Wires Rectangular Isi/Iso/Ce Marked , Cu Niti Wires Round Isi/Iso/Ce Marked , Dental Stone Isi/Iso/Ce Marked , Denture Polishing Cake Isi/Iso/Ce Marked , Diamond Disc For Lab Micro-Motor (Assorted Size)Isi/Iso/Ce Marked , Die Stone Isi/Iso/Ce Marked , Digital Films Size 11€X14” Compatible With Kodak Dry View 5800 Digital Imager Isi/Iso/Ce Marked , Digital Films Size 8€X10” Compatible With Kodak Dry View 5800 Digital Imager Isi/Iso/Ce Marked , Disclosing Agent Isi/Iso/Ce Marked , Disposable Patient Drape Sheets Size 1X1 Mtrs. , Dual Cure Resin Cement 9-11 Gm , Elastic E Chains (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Continous Types Isi/Iso/Ce Marked , Elastic E Chains (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Long Types Isi/Iso/Ce Marked , Elastic E Chains (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Short Types Isi/Iso/Ce Marked , Electro- Polishing Solutionisi/Iso/Ce Marked , Endo Ice , Esthetic Fiber Post System , Etchant 37% Phosphate Acid In Gel Form 2-4 Gm, Isi/Iso/Ce Marked , Eugenol 110 Ml/Gm Isi/Iso/Ce Marked , Expansion Screw 3 Pin (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked , Fiber-Reinforced Splinting Material- Bondable Reinforced Ribbon Fiber-Approx. 2Mm Width Isi/Iso/Ce Marked , Finishing Stones (Assorted Size) Isi/Iso/Ce Marked , Fixer & Developer Solution Set ( Autoprocessor ) To Make 1.25 Lt Solution Each Of Fixer And Developer Isi/Iso/Ce Marked , Fixer & Developer Solution Set (Manual) To Make 13.5 Lt Solution Each Of Fixer And Developer Isi/Iso/Ce Marked , Flowable Composite , Forsus Fatigue Resistant Device( 3 M Unitek ), Proprietary Itemisi/Iso/Ce Marked , Friction Grip Carbide Burs For Cutting (Different Shapes) Isi/Iso/Ce Marked , Friction Grip Carbide Burs For Finishing (Different Shapes) Isi/Iso/Ce Marked , Friction Grip Diamond Burs (Different Shapes) Isi/Iso/Ce Marked , Gates Glidden Drill No.1 , Gates Glidden Drill No.2 , Gates Glidden Drill No.3 , Glass Lonomer Luting Cement Isi/Iso/Ce Marked , Glass Lonomer Restorative Cement Isi/Iso/Ce Marked , Glass Lonomer Silver Reinforced Isi/Iso/Ce Marked , Gluteraldehyde 2.45% W/V Disinfection Solution Isi/Iso/Ce Marked , Green Stick Impression Compound Isi/Iso/Ce Marked , Gutta Percha Point No. 15-40, Isi/Iso/Ce Marked , Gutta Percha Point No. 20, Isi/Iso/Ce Marked , Gutta Percha Point No. 25, Isi/Iso/Ce Marked , Gutta Percha Point No. 30, Isi/Iso/Ce Marked , Gutta Percha Point No. 45-80, Isi/Iso/Ce Marked , Heat Cure Acrylic Liquid Isi/Iso/Ce Marked , Heat Cure Acrylic Powder Isi/Iso/Ce Marked Pink , Hybrid Composite Resin For Anteriors 3-4 Gram Isi/Iso/Ce Marked , Impression Compound Isi/Iso/Ce Marked , Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Blue Isi/Iso/Ce Marked , Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Green Isi/Iso/Ce Marked , Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Red Isi/Iso/Ce Marked , Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Yellow Isi/Iso/Ce Marked , Investent Material And Liquid (Phosphate Bonded) Isi/Iso/Ce Marked (For Chrom Cobalt) , Investent Material And Liquid (Phosphate Bonded) Isi/Iso/Ce Marked (For Porcelain) , Investment Material (Gypsum Bonded) Isi/Iso/Ce Marked , Investment Material (Silicate Bonded) Isi/Iso/Ce Marked , Iopa Film Size 30/31 Mm X 40/41 Mm (Packet Of 150 Films ) Isi/Iso/Ce Marked , Iowa Wax Isi/Iso/Ce Marked , Korecta Wax No. 4 Isi/Iso/Ce Marked , Lentulo Spiral Filler , Ligature Wire Spool 0.009€(T Porthodontics/American Orthodontics / Libral) Isi/Iso/Ce Marked , Ligature Wire Spool 0.010€(T Porthodontics/American Orthodontics / Libral) Isi/Iso/Ce Marked , Light Cure Bonding Material (Dentsply / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek )Isi/Iso/Ce Marked , Light Cure Composite Resin-Packable Isi/Iso/Ce Marked 2-4 Gm Syringe , Local Anesthetic Liganocaine 2% With Adr 1 In 80000 For Dental Use , Loose Preadjusted Edgewise Mbt Bracket 022 Slot Isi/Iso/Ce Marked Per Bracket , Matrix Band (No. 1 Toflemire)-1Si/Iso/Ce Marked , Matrix Band (No. 8 Toflemire)-1Si/Iso/Ce Marked , Maxillofacial Silicone And Stain Isi/Iso/Ce Marked , Medical X-Ray Film (1X50) 8 X10 , Mercury Pure Triple Distilled 225Gm Vial Isi/Iso/Ce Marked , Metal Polishing Cakeisi/Iso/Ce Marked , Mineral Trioxide Aggregate Isi/Iso/Ce Marked , Mock Up/Diagnostic Waxisi/Iso/Ce Marked , Modeling Wax Isi/Iso/Ce Marked , Naoci 5.25% Solution Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Rectangular -016X022 Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Rectangular -017X025 Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Rectangular -019X025 Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Round - 014 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Round - 016 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Round - 018 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Round - 020 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Nickel Chromium Alloy Isi/Iso/Ce Marked Pack Of 1 Kg , Niti Closed Coil Springs With Hooklets (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek 12Mm Isi/Iso/Ce Marked , Niti Closed Coil Springs With Hooklets (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek 9Mm Isi/Iso/Ce Marked , Ni-Ti Open Coil Spring0 10€X 030 (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marke , Occlusal X-Ray Films (57X76 Mm) Isi/Iso/Ce Marked , Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 10 Mm Isi/Iso/Ce Marked , Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 6Mm Isi/Iso/Ce Marked , Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 7Mm Isi/Iso/Ce Marked , Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 8Mm Isi/Iso/Ce Marked , Pit & Fissure Sealant Light Cure , Low Viscosity, Fluoride Releasing Isi/Iso/Ce Marked , Plaster Of Paris For Dental Use Isi/Iso/Ce Marked , Polyether Impression Material Base & Catalyst Base 300Ml, With 60 Ml Catalyst , One Dispenser With 3 Year Replacement Warranty Free With 50 Packs , Powerscope 2 (American Orthodontics Proprietary Item)Isi/Iso/Ce Marked , Pre Fabricate Metallic Post (Threaded) , Pre Fabricated Metallic Post ( Cemented) , Preadjusted Edgewise Stainless Steel Brackets Kit Containing Upper & Lower 2Nd Premolar To 2Nd Premolar Bondable Brackets With Upper Triple And Lower Double Weldable Buccaltubes,With Roth And Mbt Prescription And 0.022€And 0.018€ Slot (Leone/American Orth , Preformed Molar Bands Without Buccal Tubesisi/Iso/Ce Marked , Protemp 4 (Bisgma Temporary Crown Material) Iso/Isi/ Ce , Pumice Isi/Iso/Ce Marked , Resin Bonded Zinc Oxide-Eugenol Cement Isi/Iso/Ce Marked , Resin Cement Isi/Iso/Ce Marked , Retraction Cord (Assorted Size Isi/Iso/Ce Marked , Revo S Rotary Files Size As30 , Revo S Rotary Files Size As35 , Revo S Rotary Files Size As40 , Revo S Rotary Files Size Sc1 , Revo S Rotary Files Size Sc2 , Revo S Rotary Files Size Su , Ring Liner (Asbestos)Isi/Iso/Ce Marked , Root Canal File K 15-40, 21 Mm Pkt. Of Six Isi/Iso/ Ce Marked , Root Canal File K 15-40, 25 Mm Pkt. Of Six Isi/Iso/ Ce Marked , Root Canal File K 45-80, 25 Mm Pkt. Of Six Isi/Iso/ Ce Marked , Root Canal Files H- 15, 21 Mm Pkt. Of Six Isi/Iso/Ce Marked , Root Canal Files H- 15-40 (21 Mm) Pkt. Of Six Isi/Iso/Ce Marked , Root Canal Files H 15-40, 25 Mm Pkt. Of Six Isi/Iso/ Ce Marked , Root Canal Files H- 20 (21 Mm) Pkt. Of Six Isi/Iso/ Ce Marked , Root Canal Files H- 45-80 (25 Mm) Pkt. Of Six Isi/Iso/Ce Marked Ce Marked Pkt. Of 200 , Root Canal Files H- 45-80, 21 Mm Pkt. Of Six Isi/Iso/ Ce Marked , Root Canal Files H- No. 15 (25 Mm) Isi/Iso/Ce Marked , Root Canal Files H- No. 20 (25 Mm) Isi/Iso/Ce Marked , Root Canal Files K- 15, 21 Mm Pkt. Of Six Isi/Iso/Ce Marked , Root Canal Files K- 20 (21 Mm) Pkt. Of Six Isi/Iso/ Ce Marked , Root Canal Files K- 45-80, 21Mm Pkt. Of Six Isi/Iso/Ce Marked , Root Canal Files K- No. 10 (21 Mm) Pkt. Of Six Isi/Iso/Ce Marked , Root Canal Files K- No. 10, 25 Mm) Pkt. Of Six Isi/Iso/Ce Marked , Root Canal Files K- No. 15 (25 Mm) Isi/Iso/Ce Marked , Root Canal Files K- No. 20 (25 Mm) Isi/Iso/Ce Marked , Root Canal Files K- No. 6 (21 Mm) Pkt. Of Six Isi/Iso/Ce Marked , Root Canal Files K- No. 6, ( 25 Mm) Pkt. Of Six 197.00 Isi/Iso/Ce Marked , Root Canal Files K- No. 8,(21 Mm) Pkt. Of Six Isi/Iso/Ce Marked , Root Canal Files K- No.8, 25 Mm) Pkt. Of Six Isi/Iso/ Ce Marked , Root Canal Spreader 15-40, 21 Mm Isi/Iso/Ce Marked , Root Canal Spreader 15-40, 25 Mm Isi/Iso/Ce Marked , Rotary Niti Files With 4% Taper Size #15/17.#20,#30.##40,21 Mm And 25 Mm Pack Of 4-6, Isi/Iso/Ce Certified/Usfda , Rotary Niti Files With 6% Taper Size #15/17.#20,#30.##40,21 Mm And 25 Mm Pack Of 4-6, Isi/Iso/Ce Certified/Usfda , Rpd Pattern Wax: Clasp Patternisi/Iso/Ce Marked , Rpd Pattern Wax: Major Connector Pattern Isi/Iso/Ce Marked , Rpd Pattern Wax: Minor Connector Pattern Isi/Iso/Ce Marked , Rubber Base Impression Material Addition Silicone Putty Isi/Iso/Ce Marked , Rubber Base Impression Material Addition Silicone Putty With Compatible Light Body 600-900Ml Putty With 50 Ml Light Per 300Ml Of Putty Isi/Iso/Ce Marked , Rubber Dam Sheet Isi/Iso/Ce Marked , Sand (For Sand Blaster)(250Micron) , Sand Paper Mandrel Isi/Iso/Ce Marked , Sand Paper No 100 Isi/Iso/Ce Marked , Sand Paper No 1000 Isi/Iso/Ce Marked , Sand Paper No 120 Isi/Iso/Ce Marked , Sand Paper No 400 Isi/Iso/Ce Marked , Sand Paper No 80 Isi/Iso/Ce Marked , Self Cure Bonding Material Isi/Iso/Ce Marked , Self Polymerizing Acrylic Liquid Isi/Iso/Ce Marked , Self Polymerizing Acrylic Powder Isi/Iso/Ce Marked Pink , Shellac Base Plate Isi/Iso/Ce Marked , Silicone Adhesive Isi/Iso/Ce Marked , Silicone Interocclusal Record Material Isi/Iso/Ce Marked , Silk Suture Material (3-0) , Silver Alloy Non Gamma-2 Lathe Cut Alloy 30 Gm Vial Isi/Iso/Ce Marked , Small Cotton Rolls For Isolation Isi/Iso/Ce Marked A Pack Of 1000 Pieces , Soft Denture Liner Isi/Iso/Ce Marked , Sprue Wax (Assorted Sizes)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Rectangular 016X022 (Leone/American Orthodontics/T.P Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Rectangular 017X025 (Leone/American Orthodontics/T.P Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Rectangular 019X025 (Leone/American Orthodontics/T.P Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Round 014 Inch (Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Round 016 Inch(Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Round 018 Inch(Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Round 020 Inch(Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Wire 19 G. Soft Isi/Iso/Ce Marked , Stainless Steel Wire 21G. Soft Isi/Iso/Ce Marked , Stainless Steel Wire 26G. Soft Isi/Iso/Ce Marked , Stainless Steel Wire 30G. Soft Isi/Iso/Ce Marked , Stainless Steel Wire Spool ( Leone / Konark/Ss White) 19 Gauge Isi/Iso/Ce Marked , Stainless Steel Wire Spool ( Leone / Konark/Ss White) 20 Gauge Isi/Iso/Ce Marked , Stainless Steel Wire Spool ( Leone / Konark/Ss White) 21 Gauge Isi/Iso/Ce Marked , Stainless Steel Wire Spool ( Leone / Konark/Ss White) 23 Gauge Isi/Iso/Ce Marked , Sterilization Rolls For Packing Instrument 10Cm X 200 Mtrs. , Sterilization Rolls For Packing Instrument 15Cm X 200Mtrs , Sticky Wax Isi/Iso/Ce Marked , Suction Tips Isi/Iso/Ce Marked , Surgical Bur Straight Fissure Carbide 1 Mm Isi/Iso/Ce/Marked , Surgical Bur Straight Fissure Carbide 1.5 Mm Isi/Iso/Ce/Marked , Surgical Bur Straight Fissure Carbide 2 Mm Isi/Iso/Ce/Marked , Tma Wire Lengths Rectangular - 017 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked , Tma Wire Lengths Rectangular - 019 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked , Tma Wires Preformed Rectangular- 017 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked , Tma Wires Preformed Rectangular- 019 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked , Tooth Colored Self Cure Acrylic Resin (Self Cure) Isi/Iso/Ce Marked , Tooth Preparation Kit Set Of Minimum 14 Burs Isi/Iso/ Ce Marked , Topical Fluoride Apf Gel 1.25% Isi/Iso/Ce Marked , Tray Adhesive For Addition Siliconeisi/Iso/Ce Marked , Waxes For Fpd (Assorted Consistency) Isi/Iso/Ce Marked (Block Out, Margin Wax, Carving Wax, Dipping Wax, Blue Wax, Spacer Wax Etc.) , Zinc Oxide Eugenol Impression Paste Isi/Iso/Ce Marked Pkt. Of (100-125)+ (60-90) Gm , Zinc Oxide Non Eugenol Impression Paste Isi/Iso/Ce Marked (Catalyst + Base Past) , Zinc Oxide Non -Eugenol Luting Cement Isi/Iso/Ce Marked , Zinc Oxide Powder 110 Gram Isi/Iso/Ce Marked , Zinc Phosphate Cement 30-100 Gm With Corresponding Liquid Isi/Iso/Ce Marked , Abdominal Drain 28 No (Isi/Iso/Ce Certified) , Abdominal Drain 30 No (Isi/Iso/Ce Certified) , Abdominal Drain 32 No (Isi/Iso/Ce Certified) , Absorable Gelatin Sponge, Single Unit(Abgel) , Adhesive Plaster(Medigrip) 3 Inches , Adhesive Plaster(Medigrip) 04 Inches , Agfa Complete X Ray Cassette With I.P Size 10X12 ( (Isi/Iso/Ce Certified)) , Agfa Complete X Ray Cassette With I.P Size 14X17 ( (Isi/Iso/Ce Certified)) , Agfa Complete X Ray Cassette With I.P Size 8X10 ( (Isi/Iso/Ce Certified)) , Agfa Cr Film (Dt2b)(1X100) 10X12 (Isi/Iso/Ce Certified) , Agfa Cr Film (Dt2b)(1X100) 11X14 (Isi/Iso/Ce Certified) , Agfa Cr Film (Dt2b)(1X100) 14X17 (Isi/Iso/Ce Certified) , Agfa Cr Film (Dt2b)(1X100) 8X10 (Isi/Iso/Ce Certified) , Agfa X-Ray Cassette Without I.P 10X12 (Isi/Iso/Ce Certified) , Agfa X-Ray Cassette Without I.P Size 14X17 (Isi/Iso/Ce Certified) , Airway Set Size 2, ( Single Unit) (Isi/Iso/Ce Certified) , Airway Set Size 3, ( Single Unit) (Isi/Iso/Ce Certified) , Airway Set Size 4, ( Single Unit) (Isi/Iso/Ce Certified) , Airway Set Size 5, ( Single Unit) (Isi/Iso/Ce Certified) , Alcohol Swabs A Pack Of 1X100 Saturated With 70% Isopropyl Alcohol Celloluse Swab , Ambu Bag Adult, It Should Be Double Layered Resuscitator Within Built Pressure Limiting System That Prevents Airways Pressure From Exceeding 7 K Pa ( 70 Cm H2o Without Loss Of Valume. It Should Be Supplied With Reusable Transparent Breathing Face Mask , It Should Have Tidal Volume Max 1300 Ml It Should Be Usfda And Iso/Ce Certified. (Single Unit) , Ambu Bag Neonates, It Should Be Usfda And Iso/Ce Certified. (Single Unit) , Ambu Bag Ped, It Should Be Double Layered Resuscitator Within Built Pressure Limiting System That Prevents Airways Pressure From Exceeding 4 K Pa ( 40 Cm H2o Without Loss Of Valume. It Should Be Supplied With Reusable Transparent Breathing Face Mask , It Should Have Tidal Volume Max 300 Ml It Should Be Usfda And Iso/Ce Certified. (Single Unit) , Anterior Chamber Kellmann Multi Flex 4 Point Fixation Type Optical Diameter 6Mm,Overall Length 12.5 Mm, Dioptric Range 10D To 30 D (Isi/Iso/Ce Certified) , Anterior Chamber Pmma Iol Optical Diameter 5.25Mm , Overall Length 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range 10 D To 30 D ( Appaswamy) , Anterior Chamber Pmma Iol Optical Diameter 6 Mm , Overall Length 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range 10 D To 30 D ( Appaswamy) , Aprons (Lab Coats ) (Small) Full Sleeves , Aprons (Lab Coats ) (Small) Half Sleeves , Aprons (Lab Coats) (Large) Full Sleeves , Aprons (Lab Coats) (Large) Half Sleeves , Aprons (Lab Coats) (Medium) Full Sleeves , Aprons (Lab Coats) (Medium) Half Sleeves , B.P. Blade 23 No. (Isi/Iso/Ce Certified) , Bain Circuit Adult (Isi/Iso/Ce Certified) , Bain Circuit Pediatric (Isi/Iso/Ce Certified) , Band Aid (Regular) (Isi/Iso/Ce Certified) , Band Aid (Regular) (Jhonson & Jhonson) , Bakri Ballon Tamponade , Bakri Ballon Catheter , Bb Splint (Bohler- Braun) (Isi/Iso/Ce Certified) , Bed Sheet Size-150 X 240 Cm, All Colours , Bed Sheet Size-150 X 240 Cm, Color:Blue , Bed Sheet Size-150 X 240 Cm, Color:Green , Bed Sheet Size-150 X 240 Cm, Color:Indigo , Bed Sheet Size-150 X 240 Cm, Color:Orange , Bed Sheet Size-150 X 240 Cm, Color:Peach , Bed Sheet Size-150 X 240 Cm, Color:Violet , Bed Sheet Size-150 X 240 Cm, Color:White , Bed Sheet Size-150 X 240 Cm, Color:Yellow , Blades For Eye Surgery 2.2 Mm (Crescent) ( Appasamy)) , Blades For Eye Surgery 2.8 Mm (Keratome) ( Appasamy) , Blades For Eye Surgery 3.0 Mm ( Appasamy) , Blades For Eye Surgery 3.2 Mm ( Appasamy)) , Blades For Eye Surgery 2.6 Crescent ( Appasamy)) , Blades For Eye Surgery Implant 5.2 Mm ( Appasamy)) , Blades For Eye Surgery Side Port 15° ( Appasamy)) , Blankets,Red Standared Wt. And Size (Isi/Iso/Ce Certified) , Blood Bag Paed. 100Ml ( Romsons) , Blood Bag Paed. 100Ml (Isi/Iso/Ce Certified) , Blood Collecting Safety Syringe ( (Isi/Iso/Ce Certified)) , Blood Filter Set With Air Vent(Double Chamber) (Isi/Iso/Ce Certified) , Blood Filter Set With Air Vent(Double Chamber) (Romsons) , Cancellous Full Thread 6.5 ( (Isi/Iso/Ce Certified)) , Cassette Holding Tray (20-25 Cassette Holding Capacity) ( (Isi/Iso/Ce Certified)) , Catgut Suture (Chromic Catgut)Usp 1, 76 Cm X 63 Mm, 3/8 Circle ( (Isi/Iso/Ce Certified)) , Cautery Pad , Chest Drain (Adults) ( (Isi/Iso/Ce Certified)) , Chest Drain Bag ( (Isi/Iso/Ce Certified)) , Chest Drain Catheter No. 12 ( (Isi/Iso/Ce Certified)) , Chest Drain Catheter No. 14 ( (Isi/Iso/Ce Certified)) , Chest Drain Catheter No. 28 ( (Isi/Iso/Ce Certified)) , Chest Drain Catheter No. 32 ( (Isi/Iso/Ce Certified)) , Chest Tube Drainage With Trocar And Cannula ( (Isi/Iso/Ce Certified)) , Chest Tube With Underseal Bag 32 ( (Isi/Iso/Ce Certified)) , Cord Clamp ( (Isi/Iso/Ce Certified)) , Corugated Drain Sheet ( (Isi/Iso/Ce Certified)) , Cotton Bandages 10 Cm X 4 Mtrs(Isi Standard , Iso9001 &Gmp Certified) Rate Per Single Bandage , Cotton Bandages 15 Cm X 5 Mtrs(Isi Standard ,Iso9001& Gmp Certified)Rate Per Single Bandage , Cotton Bandages 5 Cm X 4 Mtrs(Isi Standard ,Iso 9001 & Gmp Certified)Rate Per Single Bandage , Cotton Gauze Cloth 90 Cm X 18 Mtrs(Isi Standard , Iso9001 &Gmp Certified)Rate Per Single Bandage , Cotton Pad 4 Packed Isi Marked ,Iso9001& Gmp Certified , Cotton Pad 6 Packed Isi Marked ,Iso9001& Gmp Certified , Cotton Wool Ip 100 Gm(Fine Absorbable Quality Sterlize) Nett Weight Iso9001& Gmp Certified , Cotton Wool Ip 500 Gm(Fine Absorbable Quality Sterlize) Nett Weight Iso9001&Gmp Certified , Courtery Lead ( Single Unit) ( (Isi/Iso/Ce Certified)) , Coutery Pad (Single Unit) ( (Isi/Iso/Ce Certified)) , Cpd Bag Double With Sagm 450 Ml ( (Isi/Iso/Ce Certified)) , Cpd Bag Double With Sagm 450 Ml ( Romsons) , Cpda Bag/ Blood Begs 350Ml ( (Isi/Iso/Ce Certified)) , Cpda Bag/ Blood Begs 350Ml ( Romsons) , Craner Wire Splint ( (Isi/Iso/Ce Certified)) , Crape Bandages Bp 10 Cm X 4.5 Mtrs ( (Isi/Iso/Ce Certified)) Rate Per Single Bandage , Crape Bandages Bp 15 Cm X 4.5 Mtrs(Isi Standard, Iso 9001&Gmp Certified )Rate Per Single Bandage , Dark Glasses , Dead Body Cover Size - 06 Feet Full Size , Developer For X-Ray To Make 13.5 Ltr. Solution ( (Isi/Iso/Ce Certified)) , Diaper Paediatric , Diaper Neonate , Didecyidimethyl Amonium Chloride And Benzyl C12c16 Alkyl Methyl Chloride Solution Presaturated Wipes ( (Isi/Iso/Ce Certified)) , Dispo Face Shield ( (Isi/Iso/Ce Certified)) , Disposable Adhesive Cannula Fixator (Iso 9001&Gmp Certified) , Disposable Bed Sheet , Disposable Cap With Elastic ( (Isi/Iso/Ce Certified)) , Disposable Eye Patch ( (Isi/Iso/Ce Certified)) , Disposable Eye Sticking Pad (Attached Multilayered) ( (Isi/Iso/Ce Certified)) , Disposable Eye Sticking Pad (Attached Multilayered) ( Appaswamy) , Disposable Insulin Syringe (31G) ( (Isi/Iso/Ce Certified)) , Disposable Mask With Strings ( (Isi/Iso/Ce Certified)) , Disposable Needle No. 16 ((Isi/Iso/Ce Certified) ) , Disposable Needle No. 21 No. ( (Isi/Iso/Ce Certified) , Disposable Needle No. 23(Isi/Iso/Ce Certified) , Disposable Needle No. 24 (Isi/Iso/Ce Certified) , Disposable Needle No. 26 (Isi/Iso/Ce Certified) , Disposable Nitrile Gloves 6.5 No. ( (Isi/Iso/Ce Certified)) , Disposable Nitrile Gloves 7 No. ( (Isi/Iso/Ce Certified)) , Disposable Nitrile Gloves 7.5 No ( (Isi/Iso/Ce Certified)) , Disposable Patient Drape Sheets ( (Isi/Iso/Ce Certified)) , Disposable Patient Drape Sheets ( Romsons) , Disposable Plastic Bed Pan ( (Isi/Iso/Ce Certified)) , Disposable Plastic Dropper (Capacity 3Ml)( (Isi/Iso/Ce Certified)) , Disposable Plastic Urine Pot ( (Isi/Iso/Ce Certified)) , Disposable Shoe Cover ( (Isi/Iso/Ce Certified)) , Disposable Sterile Powder Free Gloves For Eye Surgeries Size 6.5 ( (Isi/Iso/Ce Certified)) , Disposable Sterile Powder Free Gloves For Eye Surgeries Size 7 ( (Isi/Iso/Ce Certified)) , Disposable Sterile Powder Free Gloves For Eye Surgeries Size 7.5 ( (Isi/Iso/Ce Certified)) , Disposable Surgical Gloves 6 No ( (Isi/Iso/Ce Certified)) , Disposable Surgical Gloves 6.5 No ( (Isi/Iso/Ce Certified)) , Disposable Surgical Gloves 6.5 No ( Surgicare) , Disposable Surgical Gloves 7 No ( (Isi/Iso/Ce Certified)) , Disposable Surgical Gloves 7 No ( Surgicare) , Disposable Surgical Gloves 7.5 No ( (Isi/Iso/Ce Certified)) , Disposable Syringe 20 Ml With Needle ( (Isi/Iso/Ce Certified)) , Disposable Syringe 50 cement concrete With Needle ( (Isi/Iso/Ce Certified)) , Disposable Syringes 1 Ml (23G) ( (Isi/Iso/Ce Certified)) Ribbon Pack , Disposable Syringes 1 Ml With 26 No. Needle ( (Isi/Iso/Ce Certified))Ribbon Pack , Disposable Syringes 50 Ml. With Needle ( (Isi/Iso/Ce Certified)) , Disposable Syringes 10 Ml. With Needle ( (Isi/Iso/Ce Certified)) , Disposable Syringes 2 Ml With 23 No. Needle ( (Isi/Iso/Ce Certified)) , Disposable Syringes 2 Ml With 23 No. Needle ( Romsons) , Disposable Syringes 2 Ml With 24 No. Needle ( (Isi/Iso/Ce Certified)) , Disposable Syringes 2 Ml With 24 No. Needle ( Romsons) , Disposable Syringes 3 Ml With 23 No. Needle ( (Isi/Iso/Ce Certified)) , Disposable Syringes 3 Ml With 24 No. Needle (( Romsons) , Disposable Syringes 5 Ml With 23 No. Needle ( (Isi/Iso/Ce Certified)) , Disposable Syringes 5 Ml With 23 No. Needle ( Romsons) , Double Blood Bags 350 Ml , Drape Sheet For Cssd 2 X2 Mtr. Cotton Cloth Grey Color ( (Isi/Iso/Ce Certified)) , Drape Sheet For Cssd 2 X2 Mtr. Cotton Cloth Grey Color ( Romsons) , Drapes With Drainage Bag 100X80 Cm Double Layered Pre Cut ( (Isi/Iso/Ce Certified)) , Draw Sheet/ Ot Sheet, 2 Mtr , Dyna Plast Adhesive Tape ( 10 Cm Width, 5 Cm Length) Isi Marked &Gmp Certified , Ecg Electrodes (Neonate) ( (Isi/Iso/Ce Certified)) , Ecg Electrodes Adult (Disposable Kit Pack Of 6) ( (Isi/Iso/Ce Certified)) , Ecg Electrodes Pediatric (Disposable Kit Pack Of 6) ( (Isi/Iso/Ce Certified)) , Ecg Paper 50 Mm*20 Mtr, Roll ( (Isi/Iso/Ce Certified)) , Ecg Paper 50 Mm*30 Mtr, Roll ( (Isi/Iso/Ce Certified)) , Ecg Paper 60 Mm* 15 Mtr, Roll ( (Isi/Iso/Ce Certified)) , Ecg Paper 80Mm*15,20,30Mtr Roll ( (Isi/Iso/Ce Certified)) , Ecg Roll Big ( (Isi/Iso/Ce Certified)) , Ecg Roll Small ( (Isi/Iso/Ce Certified)) , Ecg Paper 215 Mm*20 Mtr, Roll (Bionet Cardiocare-2000 Model) , Ecg Paper A4 Size (Edan Machine) , Ecg Paper Recording Paper 210 Mm*20 Mtr, Roll (Bpl Cardiart-9108 Model) , Ecg Paper Recording Paper 210 Mm*300Mm*200 Sheet ( Bpl Machine Model -Cardiart 9108) , Endotrocheal Tube 2 Uncuffed (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube 2.5 Uncuffed (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube 3 Uncuffed (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube 6.5 Uncuffed (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube 7 (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube 7 Cuffed (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube 7.5 Cuffed (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube No. 3.5 Uncuffed (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube No. 4 (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube No. 5 (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube No. 5.5 (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube No. 6 (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube No. 8 (Isi, Iso9001,Ce Marked&Gmp Certified) , Endotrocheal Tube( All Sizes) Cuffed (Iso9001, Ce Marked& Gmp Certified) , Endotrocheal Tube( All Sizes) Uncuffed (Isi, Iso9001,Ce Marked&Gmp Certified) , Epidural Set , Eustachian Tube Cathetor ( (Isi/Iso/Ce Certified)) , Eustachian Tube Cathetor ( (Isi/Iso/Ce Certified)) , Examination Gloves All Sizes (Wt Min. 4.5 Gm Per Piece) ( (Isi/Iso/Ce Certified)) , Eye Drapes (Sheet) 80X70 Cm Pre Cut (Romsons) , Eye Drapes (Sheet) 80X70 Cm Pre Cut (Appasamy) , Eye Drapes (Sheet)100X80 Cm Pre- Cut (Romsons) , Eye Drapes (Sheet)100X80 Cm Pre- Cut (Appasamy) , Eye Wipes (Sterilized) ( (Isi/Iso/Ce Certified)) , Fixer For X-Ray To Make 13.5 Ltr. Solution ( (Isi/Iso/Ce Certified)) , Fluorescein Strips For Eye ( Appaswamy) , Foleys Catheter 10 ( (Isi/Iso/Ce Certified)) , Foleys Catheter 12 ( (Isi/Iso/Ce Certified)) , Foleys Catheter 14 ( (Isi/Iso/Ce Certified)) , Foleys Catheter 16 ( (Isi/Iso/Ce Certified)) , Foleys Catheter 18 ( (Isi/Iso/Ce Certified)) , Foleys Catheter 8 ( (Isi/Iso/Ce Certified)) , Fuji X-Ray Films 10X12 Dry ( (Isi/Iso/Ce Certified)) A Pack Of 100 Rate Per Pack , Fuji X-Ray Films 11X14 Dry ( (Isi/Iso/Ce Certified))A Pack Of 100 Rate Per Pack , Fuji X-Ray Films 14X17 Dry ( (Isi/Iso/Ce Certified))A Pack Of 100 Rate Per Pack , Fuji X-Ray Films 8X10 Dry ( (Isi/Iso/Ce Certified))A Pack Of 100 Rate Per Pack , Green Blade 45 Degree ( Appaswamy) , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Eliptical Pores Mesh 15.5 Cm X 8.5Cm (Pack Of 100) , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Eliptical Pores Mesh 25 Cm X 10 Cm , (Pack Of 100) , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Eliptical Pores Mesh 6.5 Cm X 5 Cm (Pack Of 100) , Guide Wire Teflon Coated V Straight Tip ( (Isi/Iso/Ce Certified)) , Gulde Wire For Interlocking/Dhs ( (Isi/Iso/Ce Certified)) , Hard Cervical Collar (Universal) Size (Isi/Iso/Ce Certified) , Hydro Dissection Cannula 26 No ( (Isi/Iso/Ce Certified)) , Hydro Dissection Cannula 27 No ( (Isi/Iso/Ce Certified)) , Hydrodisection Cannula ( (Isi/Iso/Ce Certified)) , Hydrophobic Acrylic Foldable Iols ( Aciol)In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +1.0 Ds To +30 Ds ( Appasamy) , I.V. Cannula 16 ( (Isi/Iso/Ce Certified)) , I.V. Cannula 18 ( (Isi/Iso/Ce Certified)) , I.V. Cannula 20 ( (Isi/Iso/Ce Certified)) , I.V. Cannula 22 ( (Isi/Iso/Ce Certified)) , I.V. Cannula 24 ( (Isi/Iso/Ce Certified)) , I.V. Cannula 26 ( (Isi/Iso/Ce Certified)) , I.V. Cannula 28 ( (Isi/Iso/Ce Certified)) , I.V. Flow Regulator Extension Sets ( (Isi/Iso/Ce Certified)) , I.V.Sets Disposable With Air Vent ( (Isi/Iso/Ce Certified)) , I.V.Sets Disposable With Air Vent ( Romsons) , Infant Feeding Tube 4 ( (Isi/Iso/Ce Certified)) , Infant Feeding Tube 5 ( (Isi/Iso/Ce Certified)) , Infant Feeding Tube 6 ( (Isi/Iso/Ce Certified)) , Infant Feeding Tube 7 ( (Isi/Iso/Ce Certified)) , Infant Feeding Tube 8 ( (Isi/Iso/Ce Certified)) , Infant Feeding Tube 9 ( (Isi/Iso/Ce Certified)) , Infant Feeding Tube All Sizes ( (Isi/Iso/Ce Certified)) , Infant Feeding Tube All Sizes (Iso9001, Ce Approved& Gmp Certified)) , K-90 Catheter ( (Isi/Iso/Ce Certified)) , Karman/ Mtp Cannula All Sizes, Single Unit (Iso 9001,Ce Approved& Gmp Certified) , Karman/ Mtp Cannula No. 6, Single Unit ( (Isi/Iso/Ce Certified)) , Karman/ Mtp Cannula No. 7, Single Unit ( (Isi/Iso/Ce Certified)) , Karman/ Mtp Cannula No. 8, Single Unit ( (Isi/Iso/Ce Certified)) , Kellys Pad (Isi/Iso/Ce Certified) , Kurta, Petticoat Sets Large Size , Green Strip , Lacrymal Cannula ( (Isi/Iso/Ce Certified)) , Lacrymal Cannula ( Romsons) , Lead Goggle ( (Isi/Iso/Ce Certified)) , Leuco Reduction Blood Filter Set For Blood Bank Use , Legaclip Size Lt 300 ( (Isi/Iso/Ce Certified)) , Legaclip Size Lt 400 ( (Isi/Iso/Ce Certified)) , Legging Each Leg Poplin 40 X 40 Cms. Green Color Bottom Closed , Lense Cleaner Paper ( (Isi/Iso/Ce Certified)) , Long G Sterile Single Use NeedleS 16G X 1.5 (1.6 X 38 Mm) ( (Isi/Iso/Ce Certified)) , Long G Sterile Single Use NeedleS 18G X 1.5 (1.25 X 38 Mm) ( (Isi/Iso/Ce Certified)) , Long G Sterile Single Use NeedleS 21G X 1.5 (0.8 X 38 Mm) ( (Isi/Iso/Ce Certified)) , Macroporus Partially Absorbable Mesh With Polypropylene And Polyglecaprone 15 Cm X 15 Cm (3 Foils In Each Box) ( (Isi/Iso/Ce Certified)) , Macroporus Partially Absorbable Mesh With Polypropylene And Polyglecaprone 6 Cm X 11 Cm (3 Foils In Each Box) ( (Isi/Iso/Ce Certified)) , Malicoat Catheter 4 Wings ( (Isi/Iso/Ce Certified)) , Medical X-Ray Films(1X50) 10X12 ( (Isi/Iso/Ce Certified)) , Medical X-Ray Films(1X50) 12X15 ( (Isi/Iso/Ce Certified)) , Medical X-Ray Films(1X50) 14X14 ( (Isi/Iso/Ce Certified)) , Medical X-Ray Films(1X50) 14X17 ( (Isi/Iso/Ce Certified)) , Medical X-Ray Films(1X50) 8X10 ( (Isi/Iso/Ce Certified)) , Mekentosh Rubber Per Meter (Iso9001& Isi Standard) , Merocel Nasal Dressing 10 cement concrete ( (Isi/Iso/Ce Certified)) , Merocel Nasal Dressing 8 cement concrete ( (Isi/Iso/Ce Certified)) , Micro Drip Set(Iso9001,Ce&Gmp Approved) , Micropore 1/2 ( (Isi/Iso/Ce Certified)) , Micropore/Surgical Paper Tape 25Mm X 9.1Mtr.(Iso,Ce& Gmp Certified) , Micropore/Surgical Paper Tape 50Mm X 9.1 Mtr.(Iso9001,Ce& Gmp Certified) , Micropore/Surgical Paper Tape 75Mm X 9.1 Mtr.(Isi/Iso/ Ce Marked) , Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 5X 6 Cm ( (Isi/Iso/Ce Certified)) , Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 7X 9 Cm ( (Isi/Iso/Ce Certified)) , Mr Cannula All Sizes ( (Isi/Iso/Ce Certified)) , Mr Cannula No. 5 ( (Isi/Iso/Ce Certified)) , Mr Cannula No. 6 ( (Isi/Iso/Ce Certified)) , Mr Cannula No. 7 ( (Isi/Iso/Ce Certified)) , Mr Cannula No. 8 ( (Isi/Iso/Ce Certified)) , Mucous Suction Trap ( (Isi/Iso/Ce Certified)) , Multilayer Tissue Seprating Polyglecaprone Mesh (Polydioxanone And Macroporous Polypropylene) 10Cm X 15 Cm Oval (1 Foil In Each Box) For Lap Of Hernia ( (Isi/Iso/Ce Certified)) , Multilayer Tissue Seprating Polyglecaprone Mesh (Polydioxanone And Macroporous Polypropylene) 15Cm X 15 Cm Square (1 Foil In Each Box) For Lap Of Hernia ( (Isi/Iso/Ce Certified)) , N-95 Masks ( (Isi/Iso/Ce Certified)) , Nasal Prongs (Paeditric) ( (Isi/Iso/Ce Certified)) , Nasal Prongs (Neonantal) ( (Isi/Iso/Ce Certified)) , Nasal Prongs Term & Preterm Single Patient Use With Twin Bore Nasal Pronges Sets, Extra Soft Medical Grade Nasal Tips ( (Isi/Iso/Ce Certified)) , Nebulisation Set (Mask With Tubing With Chamber (Adult ) ( (Isi/Iso/Ce Certified)) , Nebulisation Set (Mask With Tubing With Chamber (Paediatric ) ( (Isi/Iso/Ce Certified)) , Negative Suction Catheter ( (Isi/Iso/Ce Certified)) , Negative Suction Drain No. 16 ( (Isi/Iso/Ce Certified)) , Negative Suction Drain No.14 ( (Isi/Iso/Ce Certified)) , Negative Suction Drain No.18 ( (Isi/Iso/Ce Certified)) , Niv Mask (Vented With Full Face Mask) , Nrm Mask With Reservior Bag( (Isi/Iso/Ce Certified)) , Nsv Set ( (Isi/Iso/Ce Certified)) , Opsite Eye Drape Sheet 70 Cm X 70 Cm ( (Isi/Iso/Ce Certified)) , Opsite Eye Drape Sheet 70 Cm X 70 Cm ( Appasamy) , Ortho Cotton Roll 15Cmx3mm ( (Isi/Iso/Ce Certified)) , Ot Gown Poplin Length 130 X 135 Cms ArmS Length 58 X 60 Back Open Type With Provision Of Tying With String At Back Arm Should Have Elasting Cuff Or Cord For Tying At Cuff End. The Inside Of Gown Should Be Inter Lock So That There Are No Loose Threads ( (Isi/Iso/Ce Certified)) , Ot Linen Cotton White 88X88 Cm. With Hole Size 9 X 10 Cm. In Centre And Should Be Folded And Stitched So There Are No Loose Ends. ( (Isi/Iso/Ce Certified)) , Ot Linen Poplin- Green Color, Size : 130 X 180 (With Circular Hole Of Size 10 Diameters In Centers Green Color) ( (Isi/Iso/Ce Certified)) , Ot Linen Poplin- Green Color, Size : 140 X 210 ( (Isi/Iso/Ce Certified)) , Ot Linen Poplin- Green Color, Size : 90 X 140 ( (Isi/Iso/Ce Certified)) , Ot Linen Poplin- Green Color, Size : 90 X 140 (With Circular Hole Of Size 10 Diameters In Centers Green Color) ( (Isi/Iso/Ce Certified)) , Ot Linen Poplin- Green Color, Size : 90 X 90 ( (Isi/Iso/Ce Certified)) , Ot Linen Poplin- Green Color, Size : 90 X 90 (With Oval) ( (Isi/Iso/Ce Certified)) , Ot Sponges With Radio-Opaque Thread (With 8 Layers 30 Cm X 30 Cm ) ( (Isi/Iso/Ce Certified)) , Oxygen Connector Both Side Tube ( (Isi/Iso/Ce Certified)) , Oxygen Mask Adult ( (Isi/Iso/Ce Certified)) , Oxygen Mask Medium ( (Isi/Iso/Ce Certified)) , Oxygen Mask Ped. ( (Isi/Iso/Ce Certified)) , Oxygen Tubing, Suction Tubing (Different Colours) ( (Isi/Iso/Ce Certified)) , Oxygen Venti-Mask (Pvc/Disposable)Adult ( (Isi/Iso/Ce Certified)) , Oxygen Venti-Mask (Pvc/Disposable)Medium ( (Isi/Iso/Ce Certified)) , Oxygen Venti-Mask (Pvc/Disposable)Paed. ( (Isi/Iso/Ce Certified)) , Paraffin Gauze , Patient Identification Band Adult Size (Different Colours) ( (Isi/Iso/Ce Certified)) , Patient Identification Band Mother & Child Size (Different Colours) ( (Isi/Iso/Ce Certified)) , Patient Identification Band Paediatric Size (Different Colours) ( (Isi/Iso/Ce Certified)) , Pciol- Non-Foldable (All Powers As Per Requirement) (Appasamy) , Pedeatrics Iv Drip Set With Air Vent ( (Isi/Iso/Ce Certified)) , Pedia Set ( (Isi/Iso/Ce Certified)) , Picc Line 24 G, 28 G ( (Isi/Iso/Ce Certified)) , Pillow Cover Cotton Size:48 X 70 Cm, Color - Blue , Pillow Cover Cotton Size:48 X 70 Cm, Color - Green , Pillow Cover Cotton Size:48 X 70 Cm, Color - Indigo , Pillow Cover Cotton Size:48 X 70 Cm, Color - Orange , Pillow Cover Cotton Size:48 X 70 Cm, Color - Peach , Pillow Cover Cotton Size:48 X 70 Cm, Color - Violet , Pillow Cover Cotton Size:48 X 70 Cm, Color - White , Pillow Cover Cotton Size:48 X 70 Cm, Color - Yellow , Plaster Of Paris Bandages 10 Cm X 2.7 Mtrs ( (Isi/Iso/Ce Certified)) High Strength , Plaster Of Paris Bandages 15 Cm X 2.7 Mtrs ( (Isi/Iso/Ce Certified)) High Strength , Plaster Spatula ( (Isi/Iso/Ce Certified)) , Pmo Line ( (Isi/Iso/Ce Certified)) , Polyglactin (Plain) Vicryl Usp-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied ( (Isi/Iso/Ce Certified)) , Polyglactin (Plain) Vicryl Usp-1, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied ( (Isi/Iso/Ce Certified)) , Polyglactin (Plain) Vicryl Usp-3-0, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle- Round Bodied ( (Isi/Iso/Ce Certified)) , Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 26 Mm 1/2 Circle, Type Of Needle- Oval Round Body ( (Isi/Iso/Ce Certified)) , Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 31 Mm 1/2 Circle, Type Of Needle- Round Body Medium Half Circle ( (Isi/Iso/Ce Certified)) , Polymide Suture Usp 0, 1.5 M X 40 Mm Half Circle Type Of Needle- Round Bodied ( (Isi/Iso/Ce Certified)) , Polymide Suture Usp 3-0, 70 Cm X 26 Mm, 3/8Circle Type Of Needle- Reverse Cutting ( (Isi/Iso/Ce Certified)) , Polypropylene Suture Usp -1, 70 Cm X 40 Mm, 1/2 Circle Type Of Needle- Heavy Round Bodied ( (Isi/Iso/Ce Certified)) , Polypropylene Suture Usp -2-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied ( (Isi/Iso/Ce Certified)) , Posterior Chamber Pmma Iol Optical Diameter 5.25Mm , Overall Length 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +1.0 Ds To +30 Ds ( Appasamy)) , Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +1.0 D To +30 D ( Appasamy) , Ppe Kits ( (Isi/Iso/Ce Certified)) , Prolene Mesh 3X6 ( (Isi/Iso/Ce Certified)) , Prolene Mesh 4X6 ( (Isi/Iso/Ce Certified)) , Prolene Mesh 6X6 ( (Isi/Iso/Ce Certified)) , Quadruple Blood Bags 450 Ml ( (Isi/Iso/Ce Certified)) , Reverse Pervention Syringe 10 Ml 3 Pc. ( (Isi/Iso/Ce Certified)) , Reverse Pervention Syringe 5 Ml 3 Pc. ( (Isi/Iso/Ce Certified)) , Ryles Tube 10 ( (Isi/Iso/Ce Certified)) , Ryles Tube 12 ( (Isi/Iso/Ce Certified)) , Ryles Tube 14 ( (Isi/Iso/Ce Certified)) , Ryles Tube 16 ( (Isi/Iso/Ce Certified)) , Ryles Tube 8 ( (Isi/Iso/Ce Certified)) , Ryles Tube All Sizes ( (Isi/Iso/Ce Certified)) , Sanitary Napkin ( (Isi/Iso/Ce Certified)) , Scalp Vein Set No. 22 ( (Isi/Iso/Ce Certified)) , Scalp Vein Set No. 23 ( (Isi/Iso/Ce Certified)) , Scalp Vein Set No. 24 ( (Isi/Iso/Ce Certified)) , Scalp Vein Set No. 26 ( (Isi/Iso/Ce Certified)) , Scalp Vein Set No. All Sizes ( (Isi/Iso/Ce Certified)) , Short G Sterile Single Use NeedleS 21G X 1.0 (0.8 X 25 Mm) ( (Isi/Iso/Ce Certified)) , Side Port 15 Degree (Antiglare) Green Blade (Appasamy) , Side Port 45 Degree (Antiglare) Green Blade (Appasamy) , Silk Sutupak (Non Absorable Black Braided Silk Suture) Usp 1, 2* 75 Mm , 1/2 Circle R B Needle ( (Isi/Iso/Ce Certified)) , Silk Sutupak Usp 1, 75 Cm ( (Isi/Iso/Ce Certified)) , Silk Suture Usp 0, 76Cm X 45 Mm , 3/8 Circle Type Of Needle- Reverse Cutting ( (Isi/Iso/Ce Certified)) , Silk Suture Usp 3-0, 90 Cm X 16 Mm , 3/8 Circle Type Of Needle- Cutting ( (Isi/Iso/Ce Certified)) , Silk Usp 4-0, With Cutting Needle ( (Isi/Iso/Ce Certified)) , Simyl Mct Oil (Medium Chain Triglycerides And Permitted Antioxidants (Tocopherol Accetate) ( (Isi/Iso/Ce Certified)) , Single Blood Bags 350 Ml ( (Isi/Iso/Ce Certified)) , Skin Stapler Standard ( Single Unit) ( (Isi/Iso/Ce Certified)) , Skin Traction Set Small Size ( (Isi/Iso/Ce Certified)) , Small Cotton Rolls For Isolation Isi/ Iso/Ce/Marked(Length-37Mm, Dia-8-10Mm) , Soft Roll Dressing (Cast Padding) 4 ( (Isi/Iso/Ce Certified)) , Soft Roll Dressing (Cast Padding) 6 ( (Isi/Iso/Ce Certified)) , Spc Set (Suprapubic Catheter Set) ( (Isi/Iso/Ce Certified)) , Spinal Needle 23 ( (Isi/Iso/Ce Certified)) , Spinal Needle 25 ( (Isi/Iso/Ce Certified)) , Spinal Needle No. 18 ( (Isi/Iso/Ce Certified)) , Spinal Needle No. 22 ( (Isi/Iso/Ce Certified)) , Spinal Needle No. 24 ( (Isi/Iso/Ce Certified)) , Spinal Needle No. 26 ( (Isi/Iso/Ce Certified)) , Sterile Cotton Pad Packed ( (Isi/Iso/Ce Certified)) , Sterile Gauze Piece Packed ( (Isi/Iso/Ce Certified)) , Sterile Single Use NeedleS 23G X 1 (0.6 X 25 Mm) ( (Isi/Iso/Ce Certified)) , Suction Catheter No. 10 , Single Unit ( (Isi/Iso/Ce Certified)) , Suction Catheter No. 16 , Single Unit ( (Isi/Iso/Ce Certified)) , Suction Cathetor No. 12 ( (Isi/Iso/Ce Certified)) , Suction Cathetor No. 14 ( (Isi/Iso/Ce Certified)) , Suction Plain Catheter No. , 8 Disposable Pyrogen Free ( (Isi/Iso/Ce Certified)) , Suction Plain Catheter No. 6, Disposable Pyrogen Free ( (Isi/Iso/Ce Certified)) , Suction Set ( (Isi/Iso/Ce Certified)) , Suction Tips (Different Sizes No: 2, 3, 4) ( (Isi/Iso/Ce Certified)) , Surgical Blades 21 ( (Isi/Iso/Ce Certified)) , Surgical Blades 24 ( (Isi/Iso/Ce Certified)) , Surgical Blades11 ( (Isi/Iso/Ce Certified)) , Surgical Blades15 ( (Isi/Iso/Ce Certified)) , Surgical Blades20 ( (Isi/Iso/Ce Certified)) , Surgical Blades23 ( (Isi/Iso/Ce Certified)) , Surgical Stiching Needle All Sizes (Doctor) ( (Isi/Iso/Ce Certified)) , Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size 2-0, ½ Circle R.B. Needle ( (Isi/Iso/Ce Certified)) , Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size1-0, ½ Circle R.B. Needle ( (Isi/Iso/Ce Certified)) , Suture Absorbable Surgical Suture Usp (Monofilament) 70 Cm X 31 Mm, Size -2-0, ½ Circle Round Bodied Needle ( (Isi/Iso/Ce Certified)) , Suture Absorbable Surgical Suture Usp (Synthetic) Polyglactin 90 Cm X 30 Mm, Size -2-0, ½ Circle Round Bodied Needle ( (Isi/Iso/Ce Certified)) , Suture Catgut 2 No Round Body Needle ( (Isi/Iso/Ce Certified)) , Suture Non-Absorbable Surgical Suture Coated Polyester No. 5 ( (Isi/Iso/Ce Certified)) , Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) 76 Cm X 26 Mm, Size -3-0, 3/8 Circle Reverse Cutting Needle ( (Isi/Iso/Ce Certified)) , Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) 76 Cm X 30 Mm, Size -2-0, 1/2 Circle Round Body Needle ,3 Metre ( (Isi/Iso/Ce Certified)) , Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) 76 Cm X 45 Mm, Size -1-0, 3/8 Circle Reverse Cutting Needle ( (Isi/Iso/Ce Certified)) , Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) 76 Cm X 45 Mm, Size -2-0, 3/8 Circle Reverse Cutting Needle ( (Isi/Iso/Ce Certified)) , Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) 90 Cm X 30 Mm, Size -0, 1/2 Circle , Heavy Taper Cut Needle ( (Isi/Iso/Ce Certified)) , Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) , Size -3-0, 1/2 Circle R B Needle ( (Isi/Iso/Ce Certified)) , Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) ,1.5 Metre , 76 Cm X 16 Mm, Size -4-0, 3/8 Circle Cutting Needle ( (Isi/Iso/Ce Certified)) , Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) ,2 Metre , 90 Cm X 26 Mm, Size -3-0, 3/8 Circle Reverse Cutting Needle ( (Isi/Iso/Ce Certified)) , Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) 2Metre , 90 Cm X 16 Mm, Size -3-0, 3/8 Circle Cutting Needle ( (Isi/Iso/Ce Certified)) , Suture Nylon, Usp 1-0 , Circle Cutting Needle ( (Isi/Iso/Ce Certified)) , Suture Nylon, Usp 2-0 , Circle Cutting Needle ( (Isi/Iso/Ce Certified)) , Tegaderm 2, 3/8 Inch*2.3/4 Inch 6*7 Cm Tegaderm Tm Films Iv Transparent Film Iv Transparent Film Dressing Style(Latex Free) ( (Isi/Iso/Ce Certified)) , Tegaderm Water Proof Dressing ( (Isi/Iso/Ce Certified)) , Temephos 50% Larvicide As Per Standard Of Latest Govt. Guidelines ( (Isi/Iso/Ce Certified)) , Thera Bands (All Colour) ( (Isi/Iso/Ce Certified)) , Three Way Canula , Towel 56 X 115 Cms. White Color, Soft , Full Size, Sperior Quality , Tracheostomy Tubes, Size 28 (Mettalic) ( (Isi/Iso/Ce Certified)) , Tracheostomy Tubes, Size 30 (Mettalic) ( (Isi/Iso/Ce Certified)) , Tracheostomy Tubes, Size 32 (Mettalic) ( (Isi/Iso/Ce Certified)) , Triple Blood Bags 450 Ml( (Isi/Iso/Ce Certified)) , Triple Blood Bags With Sagm 450 Ml ( (Isi/Iso/Ce Certified)) , Triple Layer Mask ( (Isi/Iso/Ce Certified)) , Triple Layer Single Piece Disposable Mask ( (Isi/Iso/Ce Certified)) , Triway (Three Way Stop Clock) Lipid Resistant Pyrogen Free, Sterile, Latex Free ( (Isi/Iso/Ce Certified)) , Ultrasound Jelly 200 Ml Bottle ( (Isi/Iso/Ce Certified)) , Umbilical Catheter No. 5, (5 Fr Length 37 Cm, -31Ml/Min Pvc ( (Isi/Iso/Ce Certified)) , Umbilical Catheter No. 6 (6 Fr Length 37 Cm, -31Ml/Min Pvc ( (Isi/Iso/Ce Certified)) , Umbilical Cord Cutting Scissor ( (Isi/Iso/Ce Certified)) , Uretheral Catheter ( R-90) , Under Pad/ Molinea Sheet , Urine Bag 2000Ml ( (Isi/Iso/Ce Certified)) Rate Of Single Piece , Uro Bag (Neonates)- 100 Ml ( (Isi/Iso/Ce Certified)) , Uro Bag (Paed.) ( (Isi/Iso/Ce Certified)) , Ventuary Mask ( (Isi/Iso/Ce Certified)) , Yankur Suction Set , Zigzag Ortho Cotton Soft Roll 4 Inches 100 Gm.( (Isi/Iso/Ce Certified)) , Zigzag Ortho Cotton Soft Roll 4 Inches 100 Gm.( (Isi/Iso/Ce Certified)) , Zigzag Ortho Cotton Soft Roll 6 Inches 100Gm.( (Isi/Iso/Ce Certified)) , Zigzag Ortho Cotton Soft Roll 6 Inches 300Gm.( (Isi/Iso/Ce Certified)) , Absolute Alcohol 70% 500Ml (Isi/Iso/Ce Certified)Rate Of One Bottle , Absolute Ethanol 99.9% Pure (Testing Solution) 500Ml ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Acetone 500 Ml ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Albumin Kit 5X50ml (Isi/Iso/Ce Certified)Rate Of One Pack , Alkaline Phosphatase Kit Liquix-M 6X6 Ml (Isi/Iso/Ce Certified)Rate Of One Pack , Amylase Kit 4*10Ml (Isi/Iso/Ce Certified)Rate Of One Pack , Amylase Kit 6*6Ml (Isi/Iso/Ce Certified)Rate Of One Pack , Anti A+B+D Igg/Igm+ Ab 4 X 12 Ml ( (Isi/Iso/Ce Certified))Rate Of One Pack , Reagents Anti-Ab Serum 1X5 Ml ( (Isi/Iso/Ce Certified)) , Anti Ab 1 X 10Ml ( (Isi/Iso/Ce Certified))Rate Of One Pack , Anti Abd Kit 10 Ml ( (Isi/Iso/Ce Certified))Rate Of One Pack , Anti-A, Anti-B. Anti- D Sera A Pack Of 1X10 Ml ( (Isi/Iso/Ce Certified))Rate Of One Pack , Anti D Igg/Igm 1 X 10Ml ( (Isi/Iso/Ce Certified))Rate Of One Pack , Anti D Anti Sera (Monocolonal) 1 X 5Ml ( (Isi/Iso/Ce Certified))Rate Of One Pack , Anti-A1 (Lectin) Serum 1X5 Ml ( (Isi/Iso/Ce Certified))Rate Of One Pack , Antihuman Globulin Serum1x5 Ml ( (Isi/Iso/Ce Certified))Rate Of One Pack , Antibiotic Zone Scale , Aso Test 1X100 Test ( (Isi/Iso/Ce Certified))Rate Per Pack Of 100 , Aso Test Card ( (Isi/Iso/Ce Certified))Rate Of One Card , Bacillocid (Dimethanol And Glutaraldehyde Conc.) Sterilization Slountion, 500Ml , Balance Salt Solution (Bss Solution For Eye) Clearsol 500Ml ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Bilirubin Kit 4X60ml ( (Isi/Iso/Ce Certified))Rate Per Kit , Bio Medical Waste Dustbin Trolley With Frame 16 Litre (3 Bin Set) Ss Heavy Duty Frame (Isi/Iso/Ce Certified) , Bio Medical Waste Dustbin Trolley With Frame 16 Litre (4 Bin Set) Ss Heavy Duty Frame (Isi/Iso/Ce Certified) , Bio Medical Waste Dust Bin 10 Ltr Plastic (First) Body (Blue Black Yellow Red) ( (Isi/Iso/Ce Certified)) , Bio Medical Waste Dust Bin 10 Ltr Plastic (First) Body (Blue Black Yellow Red) Foot Operated ( (Isi/Iso/Ce Certified)) , Bio Medical Waste Dust Bin 20 Ltr Plastic (First) Body (Blue Black Yellow Red) , Bio Medical Waste Dust Bin 20 Ltr Plastic (First) Body (Blue Black Yellow Red) Foot Operated ( (Isi/Iso/Ce Certified)) , Bio Medical Waste Dust Bin 32 Ltr Plastic (First) Body (Blue Black Yellow Red) Foot Operated ( (Isi/Iso/Ce Certified)) , Bio Medical Waste Dust Bin 50 Ltr Plastic (First) Body (Blue Black Yellow Red) Foot Operated ( (Isi/Iso/Ce Certified)) , Bio Waste Poly Bag Hd/Ldpe Bag As Per Bmw Rules 2016 Thickness More Than 50 Micron/200 Gz, Non-Chlorinated,Ist Quality/Fresh Material With Printing Bio Hazard Logo,Hospital Use And Haryana Govt Supply Not For Sale (Yellow, Red, Black, Blue) Size-14X17/19X26/25X38/24X24 All Sizes (Per Kg) , Bio Hazard Sticker 4.5X4 Cm. Rate Per Sticker , Bleaching Powder 1 Kg Packing Grade 1 (Isi/Iso/Ce Certified) Rate Of 1 Kg.,Shelf Life More Than 6 Months , Bleaching Powder 25 Kg Packing Grade 1 Hdpe Bag Powder Form Minimum Chlorine Availability 34% (Isi/Iso/Ce Certified) Rate Of 25 Kg. Bag ,Shelf Life More Than 6 Months , Bloating Paper For Lab Use ( (Isi/Iso/Ce Certified) Rate Per Bloating Paper , Blood Agar100gm( (Isi/Iso/Ce Certified) Rate Of 100 Gm Pack , Blood Culture Bottle 50 Ml (Isi/Iso/Ce Certified))Rate Of One Bottle , Blood Glucose Kit 2X200ml ( (Isi/Iso/Ce Certified) Rate Per Pack 2*200Ml , Blood Grouping Rapid Card ( (Isi/Iso/Ce Certified) Rate Per Card , Blood Lancet 1 X 50 ( (Isi/Iso/Ce Certified)) Rate Per Pack Of 50 Lancets , Blood Lancet 1 X 100 ( (Isi/Iso/Ce Certified)) Rate Per Pack Of 100 Lancets , Blood Urea Kit 20Mlx5 ( (Isi/Iso/Ce Certified))Rate Per Kit , Borosil Reagent Bottle ( (Isi/Iso/Ce Certified) Rate Of One Bottle , Bovine Albumin 22% Sol. A Pack Of 1X10 Ml( (Isi/Iso/Ce Certified))Rate Of One Pack , Brain-Heart Infusion Agar 100Gm ( (Isi/Iso/Ce Certified)) Rate Of 100 Gm. Pack , Brain-Heart Infusion Broth 100Gm ( (Isi/Iso/Ce Certified) Rate Of 100 Gm. Pack , Capillery Tubes For Bt/Ct A Pack Of 1X100 Rate Per Pack Of 100 Capillary Tubes , Carbol Fuschin Stain (Ziehl-Neelsen) Hi-Media , Carbol Fuchsin Powder 25 Gm (Isi/Iso/Ce Certified)) , Carbolic Acid 400Gm.(Isi/Iso/Ce Certified)) , Cedar Wood Oil 125 G ( (Isi/Iso/Ce Certified) Rate Of One Bottle , Cefoxitin For Swab Culture Rate Per Unit , Cello Tape (White) Size- 2 Inch Rate Of Single Cello Tape , Cello Tape (Brown) Size- 4 Inch Rate Of Single Cello Tape , Chlorhexidine Gluconate 4% Spray 60Ml ( (Isi/Iso/Ce Certified) Rate Per 60Ml Pack , Chlorhexidine Gluconate+ Cetrimide Antiseptic Liquid 250 Ml Bottle ( (Isi/Iso/Ce Certified) Rate Of One Bottle , Chlorine 0.5 Gm Pellets (Drinkwell) Packing 1000 Fda/ Iso/Gmp Certified , Rate Of 1000 Pellets, Shelf Life At Least One Year , Chocolate Agar 100Gm ( (Isi/Iso/Ce Certified) Rate Per Pack , Cholestrol Kit 5 X 20Ml ( (Isi/Iso/Ce Certified) Rate Per Pack , Citrate Medium 100Gm (Isi/Iso/Ce Certified) Rate Per Pack , Cleaning Solution Kit For Easylyte Na/K/Ck Rate Per Pack , Cled Medium 100Gm ( (Isi/Iso/Ce Certified) Rate Of 100Gm. , Coplin Jar Rate Of Single Jar , Copper Sulphate 500Gm ( (Isi/Iso/Ce Certified) Rate Of 500 Gm. Pack , Cover Slips Square A Pack Of 20X10 Gm Blue Star Rate Of Single Pack , Coverslip (English Glass) Size: 22 X 50Mm ( (Isi/Iso/Ce Certified))Rate Per Slip , Coverslip (English Glass) Size: 24 X 50Mm ( (Isi/Iso/Ce Certified))Rate Per Slip , Coverslip (English Glass) Size: 24 X 60Mm ( (Isi/Iso/Ce Certified))Rate Per Slip , Cpkmb Kit 2*8 /2*2 Ml( (Isi/Iso/Ce Certified)) Rate Per Pack , Creatinine Kit 4X60ml ( (Isi/Iso/Ce Certified))Rate Per Pack , Crom Agar 100Gm( (Isi/Iso/Ce Certified))Rate Per Pack , Crp Kit 1X10 Ml ( (Isi/Iso/Ce Certified))Rate Per Pack , Crp Kit Slide Method Qualitative ( (Isi/Iso/Ce Certified))Rate Per Pack , Crp Rapid Card ( (Isi/Iso/Ce Certified)) Rate Per Card , Crystal Violet 100 Gm. , Culture Tube With Swab Stick Rate Per Culture Tube With Swab Stick , Cyphenothrin 5% Ecs (Insecticide/Adulticide For Fogging) As Per Govt Guidelines 1 Litre (Bayer) , Decalcifying Reagent ( (Isi/Iso/Ce Certified)) , Deltamethrin 2.5%, Wp 25 Kg , Dengue Elisa Kit 48 Test ( Isi/Iso/Ce Certified))Rate Per Pack , Dengue Elisa Kit 48 Test J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor Rate Per Pack , Dengue Elisa Kit 48 Test ( J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor) Rate Per Pack , Dengue Elisa Kit 96 Test ( (Isi/Iso/Ce Certified)) , Dengue Elisa Kit 96 Test ( J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor)Rate Per Pack , Dengue Elisa Kit 96 Test J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor Rate Per Pack , Dengue Rapid Test Card Ns1 (Single Test) ( (Isi/Iso/Ce Certified)) Rate Per Card , Diamond Pencil Marker Standard Quality Rate Per Piece , D - Dimer Vial (Isi/Iso/Ce Certified) , Distilled Water (Dionised) 1 Litre ( (Isi/Iso/Ce Certified))Rate Per Pack , Distilled Water (Zero Tds) 5 Litre ( (Isi/Iso/Ce Certified))Rate Per Pack , Dpx Mounting Media 250Ml Each , Dropping Bottle 100Ml ( (Isi/Iso/Ce Certified)) , Dropping Bottle 250Ml ( (Isi/Iso/Ce Certified)) , Dodecylbispropylene Triamine 9.2Gm, Didecyldimethyl Ammonium Chloride 13.0 Gm For Fogging (Isi/Iso/Ce Certified) , Durhams Tube A Pack Of 1X100 Rate Per Pack , Drumsticks (Isi/Iso/Ce Certified) , Edta 17% Paste Form ( (Isi/Iso/Ce Certified)) , Eeg Paste , Elisa Covid -19 Kit A Pack Of 96 Tests (As Per Icmr/ Niv) (Isi/Iso/Ce Certified)) Rate Per Pack , Elisa Covid -19 Kit A Pack Of 48 Tests (As Per Icmr/ Niv) ( (Isi/Iso/Ce Certified)) Rate Per Pack , Elisa Hbv Kit 96Test 3Rd Generation ( (Isi/Iso/Ce Certified))Rate Per Pack , Elisa Hbv Kit 96Test 3Rd Generation J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor Rate Per Pack , Elisa Hbv Kit 96Test 4Th Generation ( (Isi/Iso/Ce Certified))Rate Per Pack , Elisa Hbv Kit 96Test 4Th Generation J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor Rate Per Pack , Elisa Hcv Kit 96Test 3Rd Generation ( (Isi/Iso/Ce Certified))Rate Per Pack , Elisa Hcv Kit 96Test 3Rd Generation J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor Rate Per Pack , Elisa Hcv Kit 96Test 4Th Generation ( (Isi/Iso/Ce Certified))Rate Per Pack , Elisa Hcv Kit 96Test 4Th Generation J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor Rate Per Pack , Elisa Hiv Kit 96Test 3Rd Generation ( (Isi/Iso/Ce Certified))Rate Per Pack , Elisa Hiv Kit 96Test 3Rd Generation J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor Rate Per Pack , Elisa Hiv Kit 96Test 4Th Generation ( (Isi/Iso/Ce Certified))Rate Per Pack , Elisa Hiv Kit 96Test 4Th Generation J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor Rate Per Pack , Eosin Powder 1X25 Gm. Rate Per Pack (Isi/Iso/Ce Certified) , Esr Pipette Rate Per Pipette (Isi/Iso/Ce Certified) , Ethanol Spray 70% , Fields Stain ( (Isi/Iso/Ce Certified)) , Filter Paper (Whatman)(A Pack 1X100) ( (Isi/Iso/Ce Certified)) Rate Per Pack , Filter Paper (Whatman)(A Pack 1X50) ( (Isi/Iso/Ce Certified)) Rate Per Pack , Filter Paper No. 1 (A Pack 1X100) ( (Isi/Iso/Ce Certified)) Rate Per Pack , Fluorescein Stain ( (Isi/Iso/Ce Certified)) , Fobt Card ( (Isi/Iso/Ce Certified) Rate Per Card , Formalin Solution 37-40% Buffered 500Ml ( (Isi/Iso/Ce Certified)) Rate Of One Bottle , Formalin Solution 37-40% Buffered 5 Litre ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Funnel 3 Inch ( (Isi/Iso/Ce Certified))Rate Of One Funnel , GeimsaS Stain Solution Bottle ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Giemsa Stain ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Glacial Acetic Acid 3.5% Solution 500 Ml ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Glass Beaker 50 Ml (Borosil) Rate Of Single Beaker , Glass Beaker 100 Ml (Borosil) Rate Of Single Beaker , Glass Beaker2 50 Ml (Borosil) Rate Of Single Beaker , Glass Beaker 500 Ml (Borosil) Rate Of Single Beaker , Glass Funnel (Borosil) Rate Of Single Funnel , Glass Cleaner 500Ml ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Glass Slide Cabinet (1000 Slide Storage Capacity) ( (Isi/Iso/Ce Certified)) , Glass Slides , A Pack Of 50 Slides ( (Isi/Iso/Ce Certified)) Rate Of 50 Slides Pack , Glutraldehyde Solution 2 % - 2.5 %, 1 Ltr (Isi/Iso/Ce Certified) , Glucometer (Dr.Morpen ,Model-Bg03) , Glucometer Strips (Dr.Morpen ,Model- Bg03) ( Rate Per Strip) , Glucometer Cell (Dr.Morpen ,Model-Bg03) , Glucometer (J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor) , Gluco Strips (J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor) ( Rate Per Strip) , Glucometer Cell (J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor) , Glucometer (Accu Chek) , Gluco Strips (Accu Chek) A Pack Of 2X50 Strips ( Rate For Pack Of 2X50 Strips) , Glucometer Cell (Accu Chek) , Glycerol 100Ml (Isi/Iso/Ce Certified) , Graduated Glass Measuring Cylinder ( 1000Ml) ( (Isi/Iso/Ce Certified)) , Graduated Glass Measuring Cylinder (500Ml ) ( (Isi/Iso/Ce Certified)) , Gram Stain 100Ml ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Gram Stain Kit ( (Isi/Iso/Ce Certified) Rate Of One Kit , Gram Stain Kit ( Hi-Media))Rate Of One Kit , Hand Sanitizer 400 Ml (Isi/Iso/Ce Certified) , H& E Stain (Harris) Powder Hi-Media Rate Of One Pack , Haemoglobin Meter (Round) Manual ( (Isi/Iso/Ce Certified)) , Haemoglobin Meter (Sqaure) Manual ( (Isi/Iso/Ce Certified)) , Haemoglobin Meter Glass Tube (Round) ( (Isi/Iso/Ce Certified)) , Haemoglobin Meter Glass Tube (Sqaure) ( (Isi/Iso/Ce Certified)) , Haemostatic Tournique (Isi/Iso/Ce Certified) , Hav Card ( (Isi/Iso/Ce Certified)) Rate Of One Card , Hb Meter Digital Portable With One Year Replacement Warranty ( Sensa Core) , Hb Meter Strips (Sensa Core Hb Digital Portable Meter ) Rate Per Strip , Hb Meter Digital Portable With One Year Replacement Warranty (Mission) , Hb Meter Strips ( Mission) Rate Per Strip , Hb Pipette ( (Isi/Iso/Ce Certified))Rate Of One Pipette , Hba1c Turbosmart ( (Isi/Iso/Ce Certified)) Rate Of One Card , Hbsag + Hiv + Hcv Rapid Card (Combo) ( (Isi/Iso/Ce Certified)) Rate Of One Card , Hbsag 96 Test Elisa ( (Isi/Iso/Ce Certified)) Rate Of One Kit , Hbsag 96 Test Elisa ( J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor )) Rate Of One Kit , Hbsag Card ( (Isi/Iso/Ce Certified)) Rate Of One Card , Hbsag Card ( Aspen) Rate Of One Card , Hbsag Tridot Rapid Card ( J.Mitra)) Rate Of One Card , Hbsag Card Extra Sensitive ( (Isi/Iso/Ce Certified)) , Hcl N/10 500Ml ( (Isi/Iso/Ce Certified)) Rate Of One Bottle , Hcl Concentrated 500 Ml ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Hcv & Hiv Card ( (Isi/Iso/Ce Certified))Rate Of One Card , Hcv Rapid Card ( (Isi/Iso/Ce Certified))Rate Of One Card , Hcv Rapid (Single Test Card) ( Aspen))Rate Of One Card , Hcv Tridot ( (Isi/Iso/Ce Certified))Rate Of One Card , Hcv Tridot ( J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor)Rate Of One Card , Hcv, Hiv, Hbsag, Syphilis Card 4 In 1 ( (Isi/Iso/Ce Certified))Rate Of One Card , Hiv 1/2 Card ( (Isi/Iso/Ce Certified))Rate Of One Card , Hiv Card Retroquic Flow Through Method ( (Isi/Iso/Ce Certified)) , Hiv Rapid (Single Test Card) ( (Isi/Iso/Ce Certified))Rate Of One Card , Hiv Rapid (Single Test Card) ( Aspen))Rate Of One Card , Hiv Tridot ( (Isi/Iso/Ce Certified))Rate Of One Card , Hiv Tridot ( J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor)Rate Of One Card , Hiv Complete Safe Kit ( (Isi/Iso/Ce Certified))Rate Of One Safe Kit , Hiv+Syphillis Combo ( (Isi/Iso/Ce Certified)) , Holder Lancet (Single Use/Single Packing)) ( (Isi/Iso/Ce Certified))Rate Of One Holder Lancet , Ice Gel Pack 100Gram Rate Of Single Ice Gel Pack , I.O Dye (Rhex Id Dye) Each (Indigo Blue Dye)Rate Of Single Dye , Immersion Oil For Microscopy, 100X Lens (Heavy Grade) A Pack Of 30Ml(( (Isi/Iso/Ce Certified))Rate Of One Pack , Immersion Oil For Microscopy, 100X Lens A Pack Of 30Ml (Hi-Media))Rate Of One Pack , Isopropyl Alcohol 500 Ml For Lab Use ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Isopropyl Alcohol Based Handwash Solution 5 Ltr. , Isopropyl Alcohol Based Handwash Solution 500 Ml , Jsb Stain I 250Ml ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Kimberlay Clark Tissue Paper Rate Of One Packet , Lead Pencil / Cautery Pencil (Isi/Iso/Ce Certified) , Leishman Stain ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Liquid Hand Wash Soap 5 Litre (Safe For Skin)Isi/Iso/Gmp Certified , Macconkey Brouth 500Gm (Purple) Rate Of Pack 500Gm. , Macconky Agar 100Gm ( (Isi/Iso/Ce Certified))Rate Of Pack 100Gm. , Malicot Tube 28 No. Rate Of One Tube (Isi/Iso/Ce Certified) , Malaria Antigen Card (Isi/Iso/Ce Certified))Rate Of One Card , Malaria Antigen Card J.Mitra ( (Isi/Iso/Ce Certified))Rate Of One Card , Malaria Parasite Kit ( (Isi/Iso/Ce Certified)) Rate Of One Kit , Malaria Pcr Kit Himedia( (Isi/Iso/Ce Certified)) Rate Of One Kit , Malaria Pan Elisa 96 Test ( (Isi/Iso/Ce Certified)) Rate Of One Kit Of 96 Tests , Malathion 50% Ec, 1 Ltr (Isi/Iso/Ce Certified) , Malathion Technical 95%, 25 Kg (Isi/Iso/Ce Certified) , May Grunwald Stain Solution Bottle 125Ml( (Isi/Iso/Ce Certified))Rate Of One Bottle , Mct Rack ( (Isi/Iso/Ce Certified)) , Methanol 500Ml ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Methylene Blue Alkaline ( (Isi/Iso/Ce Certified)) Rate Of One Pack , Mgg Stain ( (Isi/Iso/Ce Certified)) , Micro Centrifuge Tube 2Ml Sterile A Pack Of 1X500 (Tarson ) Rate Per Pack Of 500 , Microcuvettes (Model- Haemocue Hb 301, Hb Meter), ( Rate Per Single Microcuvettes) , Micro Pipette 0- 50 Microlitre ( (Isi/Iso/Ce Certified)) Rate Of One Pipette , Micro Pipette 10 Ul To 100 Ul ( (Isi/Iso/Ce Certified)) Rate Of One Pipette , Micro Pipette 2 Ul To 20 Ul ( (Isi/Iso/Ce Certified)) Rate Of One Pipette , Micro Pipettes 20Ul To 200Ul ( (Isi/Iso/Ce Certified)) Rate Of One Pipette , Micro Slides ( (Isi/Iso/Ce Certified)) Rate Of One Pack , Microscope Optical Lens Cleaning Solution ( (Isi/Iso/Ce Certified)) Rate Of One Pack , Microtips (2 Ul-200 Ul)A Pack Of 1X1000 Microtips( (Isi/Iso/Ce Certified))Rate Of One Pack Of 1000 , Microtips 0 - 200 Microliters (Small) A Pack Of 1X1000 Microtips( (Isi/Iso/Ce Certified))Rate Per Pack Of 1000 , Microtips 20 - 1000 Microliters (Large)A Pack Of 1X1000 Microtips( (Isi/Iso/Ce Certified))Rate Per Pack Of 1000 , Microtips 200 Ul To 1000 Ul A Pack Of 1X1000 Microtips( (Isi/Iso/Ce Certified))Rate Per Pack Of 1000 , Microtips Box (2 Ul-200 Ul)A Pack Of 1X1000 Microtips( (Isi/Iso/Ce Certified))Rate Of Per Pack Of 1000 , Microtips Box (200 Ul-1000 Ul)A Pack Of 1X1000 Microtips( (Isi/Iso/Ce Certified))Rate Per Pack Of 1000 , Mi-Fog(Disinfectant Liquid For Fogging Machine) Benzalkonium Chloride 13.6%W/V,Didecyl Dimethyl Ammonium Chloride 13%W/V,Poly Hexa Methlene Biguanide Hcl 5.0%W/V, 5Th Generation Qac For Ot,Icu,Nicu& Other Critical Areas , 1 Litre , Mineral Trioxide Aggregate Isi/ Iso/Ce/Marked. Rate Of One Pack , Mini-Shaker For Immunology ( (Isi/Iso/Ce Certified))Rate Of One Pack , Mx Vial (Montux Vial) Rate Per Vial , Muller Hilton Agar 100Gm ( (Isi/Iso/Ce Certified))Rate Of One Pack , Muller Hilton Agar Plate ( (Isi/Iso/Ce Certified))Rate Of One Plate , Multi Drug Test Kit (Panel Of 6) ( (Isi/Iso/Ce Certified)) , Multichannel Pipette (8 Channal) ( (Isi/Iso/Ce Certified)) , Multichannel Pipette (8 Channal Variable Value 2-20Ul) Thermo Fischer ( (Isi/Iso/Ce Certified)) , Multichannel Pipette (12 Channal) ( (Isi/Iso/Ce Certified)) , Multichannel Pipette (12 Channal) Thermo Fischer ( (Isi/Iso/Ce Certified)) , Multidrug Test Kit Of 10 Parameter ( (Isi/Iso/Ce Certified)) Rate Of One Kit , Multidrug Test Card 10 Parameter ( (Isi/Iso/Ce Certified)) Rate Of One Card , Multi-Sample Vacutainer Luer-Lok Access Adapters ( (Isi/Iso/Ce Certified)) , Multi-Sample Vacutainer Routine Blood Collection Sterile Single Use Needles (21G X 1Inch)(0.8 X 25/32Mm) ( (Isi/Iso/Ce Certified)) , Multi-Sample Vacutainer Routine Blood Collection Sterile Single Use Needles (22G X 1Inch)(0.7 X 25/32Mm) ( (Isi/Iso/Ce Certified)) , Nutrient Agar Media 100 Gm ( (Isi/Iso/Ce Certified))Rate Of One Pack , Objective ( Oil Immersions 100X) ( (Isi/Iso/Ce Certified))Rate Of One Pack , Objective ( Oil Immersions 10X) ( (Isi/Iso/Ce Certified))Rate Of One Pack , Objective ( Oil Immersions 40X) ( (Isi/Iso/Ce Certified))Rate Of One Pack , O- Toludine Reagent (Isi/Iso/Ce Certified) A Pack Of 500Ml Rate Per Bottle , Pap Stain Kit (Isi/Iso/Ce Certified) Rate Per Kit , Pap Stain Kit J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor (Isi/Iso/Ce Certified) Rate Per Kit , Paraffin Wax Small Cubes ( (Isi/Iso/Ce Certified))Rate Of One Pack , Parafilm Width2 Inch & Length 250 Feet ( (Isi/Iso/Ce Certified))Rate Of One Pack , Paraldehyde Solution For Sterlization ( (Isi/Iso/Ce Certified))Rate Of One Pack , Pasteur Pipette(Transfer Pipette) Capacity 1Ml ( (Isi/Iso/Ce Certified)) , Peptone Water 100Gm ( (Isi/Iso/Ce Certified))Rate Of One Bottle , Permanent Marker 10 Pieces Per Pack Black/Blue Colour Rate Per Pack , Petridish Diameter 90Mm* Height 15 Mm Sterile ( (Isi/Iso/Ce Certified)) Rate Of Single Unit , Ph Meter Digital ( (Isi/Iso/Ce Certified)) Rate Per Meter , Ph Paper (1X100) ( (Isi/Iso/Ce Certified)) Rate Per Pack Of 100 , Ph Testing Strips For Water Seven Quality Test (1X50) ( (Isi/Iso/Ce Certified)) Rate Per Pack Of 50 , Ph Testing Strips For Water Quality Test (1X100) ( (Isi/Iso/Ce Certified)) Rate Per Pack Of 100 , Phenol 2% A Pack Of 500 Ml (Isi/Iso/Ce Certified)) Rate Per Pack , Phenol 40% A Pack Of 5 Litre (Isi/Iso/Ce Certified)) Rate Per Pack , Phenol Crystal A Pack Of 500Gram (Isi/Iso/Ce Certified)) Rate Per Pack , Phenyl Surface Disinfectant,Floor Cleaner Liquid 5 Litre , White Colour ( (Isi/Iso/Ce Certified)) , Phenyl Surface Disinfectant,Floor Cleaner Liquid 5 Litre( Black Colour) ( (Isi/Iso/Ce Certified)) , Pipette Shaker ( (Isi/Iso/Ce Certified)) , Plaintube Glass 18*150 Mm, 27 Ml ( (Isi/Iso/Ce Certified)) Rate Of One Glass Tube , Plaintube Plastic 18*150Mm ,27 Ml( (Isi/Iso/Ce Certified)) Rate Of One Plastic Tube , Plaintube Plastic ( (Isi/Iso/Ce Certified)) Rate Of One Plastic Tube , Plastic Tube For Dengue Testing( (Isi/Iso/Ce Certified)) Rate Of One Plastic Tube , Plastic Container For Storing Buffered Formalin 5Litres ( (Isi/Iso/Ce Certified)) , Plastic Spatula ( (Isi/Iso/Ce Certified)) , Plastic Cane 5 Litre White Rate Per Cane , Plastic Cane 5 Litre Black Rate Per Cane , Plastic Bottle 1 Litre For Tb Programme Rate Per Bottle , Plastic/ Glass Jars For Storage Of Specimens With Fixative (50Ml Capacity) ( (Isi/Iso/Ce Certified)) , Plastic/Glass Jars For Storage Of Specimens With Fixative (100Ml Capacity) ( (Isi/Iso/Ce Certified)) , Plastic/Glass Jars For Storage Of Specimens With Fixative (200Ml Capacity) ( (Isi/Iso/Ce Certified)) , Plastic/Glass Jars For Storage Of Specimens With Fixative (500Ml Capacity) ( (Isi/Iso/Ce Certified)) , Plastic/Glass Jars For Storage Of Specimens With Fixative (1000Ml Capacity) ( (Isi/Iso/Ce Certified)) , Platelet Diluting Fluid ( (Isi/Iso/Ce Certified)) , Potash Alum 1X500gm. Rate Per Pack , Podophylline Resin Solution 10% To 25% ( (Isi/Iso/Ce Certified)) , Pot. Dichromate ( (Isi/Iso/Ce Certified)) , Prefilled Automated Extraction Kits (For Thermo Scientifix For Kingfisher Flex Automated Extraction System ,96 Well) Rt-Pcr Lab , Pregnancy Test Kit ( (Isi/Iso/Ce Certified)) Rate Of Single Kit , Pregnancy Test Card ( (Isi/Iso/Ce Certified)) Rate Of Single Card , Pregnancy Strips ( (Isi/Iso/Ce Certified)) Rate Of Single Strip , Pyrethrum Extract 2% (Isi/Iso/Ce Certified) , Q-Way 6 Inches ,Sterlized Using Ethylene Oxide ( (Isi/Iso/Ce Certified)) , R A Factor Rapid Card ( (Isi/Iso/Ce Certified)) Rate Of Single Card , Ra Factor Kit ( (Isi/Iso/Ce Certified))Rate Of Single Kit , Rapid Afb Stain Kit ( (Isi/Iso/Ce Certified))Rate Of Single Kit , Rapid Antigen Test Card (Covid) ( (Isi/Iso/Ce Certified)) Rate Of Single Card , Rapid Cytochrome/Modified Rapid Leishman Stain ( (Isi/Iso/Ce Certified)) , Rapid Geimsa Stain Kit ( (Isi/Iso/Ce Certified))Rate Of Single Kit , Rapid H & E Stain Kit ( (Isi/Iso/Ce Certified)) , Rbc Diluting Fluid ( (Isi/Iso/Ce Certified)) , Ria Vials Glass 1X100(Isi/Iso/Ce Certified)) Rate Of 100 Vials Packing , Ria Vials Plastic 12X40mm 1X500(Isi/Iso/Ce Certified)) Rate Of 500 Vials Packing , Rpr/Vdrl Kit (50 Test Each) ( (Isi/Iso/Ce Certified))Rate Of Single Kit , Rpr/Vdrl Kit (100 Test Each) ( S D Biosensor)Rate Of Single Kit , Rubber Teats Rate Per Piece , Rubber Gloves For Lab Use Rate Per Pair , Simyl Mct Oil (Medium Chain Triglycerides And Permitted Antioxidants (Tocopherol Accetate) (Isi/Iso/Ce Certified) , S. Calcium Kit A Pack Of 2X50 Ml( (Isi/Iso/Ce Certified))Rate Of Single Kit , S. Cholesterol Kit A Pack Of 5X30ml ( (Isi/Iso/Ce Certified))Rate Of Single Kit , S. Phosphorus Kit A Pack Of 2X50ml( (Isi/Iso/Ce Certified))Rate Of Single Kit , S. Protein Kit 5X50 ( (Isi/Iso/Ce Certified))Rate Of Single Kit , Salt Testing Kit ( (Isi/Iso/Ce Certified)) Rate Per Kit , Sample Cups With Lid & Sticker 30Ml ( (Isi/Iso/Ce Certified)) , Saturated Picric Acid Solution ( (Isi/Iso/Ce Certified)) , Sda Agar 100Gm ( (Isi/Iso/Ce Certified)) , Self Polymerizing Acrylic Liquid (Isi/Iso/Ce Certified) , Self Polymerizing Acrylic Powder (Isi/Iso/Ce Certified) Pink , Semen Diluting Fluid ( (Isi/Iso/Ce Certified)) , Serum Pti Kit ( (Isi/Iso/Ce Certified))Rate Of Single Kit , Serum Seperate Tube A Pack Of 1X100 Rate Per Pack , Sgot Kit 20Mlx05 ( (Isi/Iso/Ce Certified)) , Sgpt Kit 20Mlx05 ( (Isi/Iso/Ce Certified)) , Sharp Container 1.5 Litre, White ( (Isi/Iso/Ce Certified)) , Sharp Container 6 Litre, White ( (Isi/Iso/Ce Certified)) , Sharp Container 10 Litre, White ( (Isi/Iso/Ce Certified)) , Slide Mountant Dpx ( (Isi/Iso/Ce Certified)) , Slide Carrying Tray (20 Slide Capacity) ( (Isi/Iso/Ce Certified)) , Slide Labelling Stickers/Tape Roll ( (Isi/Iso/Ce Certified)) , Slide Staining Racks Aluminium( (Isi/Iso/Ce Certified)) , Slide Storage Box (100 Slide Capacity) ( (Isi/Iso/Ce Certified)) , Slide Tissue Adhesive(Hydophillic Slides) (Egg Albumin) ( (Isi/Iso/Ce Certified)) , Sodium Citrate 3.8% A Pack Of 500 Ml Rate Per Pack , Sodium Hypochloride 5% Solution 5 Ltr ( (Isi/Iso/Ce Certified)) , Sod. Hypochloride 400 Ml (Idc) , Sodium Hypochlorite Solution 10% 5 Ltr ( (Isi/Iso/Ce Certified)) , Sodium Phosphate Dibasic (Na2hpo4) Buffer ( (Isi/Iso/Ce Certified)) , Sodium Phosphate Monobasic (Nah2po4) Buffer ( (Isi/Iso/Ce Certified)) , Sodalime Crystal (Isi/Iso/Ce Certified) , Solution Pack For Easylyte Na/K/Cl , Spirit Lamp , Sulphuric Acid Con. 500 Ml ( (Isi/Iso/Ce Certified))Rate Per Bottle , Sulphuric Acid Solution 20% V/V (( (Isi/Iso/Ce Certified)) , Sulphur Powder 1X500gm. Rate Per Pack (Isi/Iso/Ce Certified) , Sputum Cup With Lid & Sticker 30Ml ( (Isi/Iso/Ce Certified)) , Sputum Cup With Lid 50Ml & Sticker ( (Isi/Iso/Ce Certified)) , Sputum Cup Carrier Box( (Isi/Iso/Ce Certified)) , Adhesive Label For Sputum Cup A Pack Of 1X100 Pieces , Surgical Spirit Bp 500Ml ( (Isi/Iso/Ce Certified)) Rate Per Bottle , Surgical Spirit Bp 5Ltr ( (Isi/Iso/Ce Certified))Rate Per Bottle , Sugar Sucrose A Pack Of 500Gm. (Isi/Iso/Ce Certified) , Sugar Maltose A Pack Of 500Gm.(Isi/Iso/Ce Certified) , Swab Sticks 100 Pcs. Rate Of 100 Sticks , Tcbs Agar100gm ( (Isi/Iso/Ce Certified)) , Tds Meter Digital , Rate Per Tds Meter , Test Tube Glass (150 X 16) A Pack Of 1X12 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Test Tube Glass (150 X 20) A Pack Of 1X12 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Test Tube Glass (80Mmx10mm) A Pack Of 1X12 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Test Tube Plastic Pack Of 1X48 Tubes ( (Isi/Iso/Ce Certified)) Rate Per Pack , Test Tube Rack 18 Hole (Plastic)(Isi/Iso/Ce Certified) , Test Tube Rack 18 Hole (Ss)(Isi/Iso/Ce Certified) , Test Tube Rack 96 Test Plastic(Isi/Iso/Ce Certified) , Test Tube Rack 96 Test Ss(Isi/Iso/Ce Certified) , Test Tubes Brush (Isi/Iso/Ce Certified) , Thermal Printing Roll For Urine Analyzer And Cbc 57/58Mm Size , Thermol Roll 57Mm ,50Mm Rate Per Roll(Isi/Iso/Ce Certified) , Thermocol Box Size 18.5X12.5X13 Cm. , Thphoid (Igg + Igm) Card ( (Isi/Iso/Ce Certified)) Rate Per Card , Thphoid (Igm) Card ( (Isi/Iso/Ce Certified))Rate Per Card , Tissue Paper Roll Double Ply Length 30 Metres Width 30 10 Cm. Rate Of Single Roll , Tourniquet Superior Quality ( (Isi/Iso/Ce Certified)) Rate Per Piece , Triglyceride Kit 2X50ml Erba Rate Of Single Kit , Triple Sugar Iron Test (Tsi) 100Gm , Trop I Kit A Pack Of ( (Isi/Iso/Ce Certified))Rate Of Single Kit , Troponin Kit ( (Isi/Iso/Ce Certified))Rate Of Single Kit , Tryptan Blue Dye ( (Isi/Iso/Ce Certified)) , Tubes Dispoables 12X100 Mm. A Pack Of 100 Tubes Rate Per Pack , Tube Racks (10 Ml Vials)(Isi/Iso/Ce Certified) , Tube Racks (5Ml Vials)(Isi/Iso/Ce Certified) , Tuberack 18*150 Mm (Isi/Iso/Ce Certified) , Turp Loop ( (Isi/Iso/Ce Certified))(Isi/Iso/Ce Certified) , Twin Bucket 10 Litre Grade One Plastic Body(Isi/Iso/Ce Certified) , Twin Bucket 20 Litre Grade One Plastic Body(Isi/Iso/Ce Certified) , Urease Medium 100Gm ( (Isi/Iso/Ce Certified)) , Uric Acid Kit 5X50ml ( (Isi/Iso/Ce Certified))Rate Of Pack , Urine Containers With Lid & Sticker (50Ml Capacity) ( (Isi/Iso/Ce Certified)) , Urine Containers With Lid & Sticker (50Ml Capacity) A Pack Of 1X100 Non-Sterile ( (Isi/Iso/Ce Certified)) Rate Of Pack , Urine Containers With Lid & Sticker 30Ml Non Sterile ( (Isi/Iso/Ce Certified) , Urine Containers With Lid & Sticker 30Ml Sterile ( (Isi/Iso/Ce Certified) , Urine Droppers 5 Ml ( A Pack Of 1X100) Rate Of Pack , Multisticks Urine Analysis Reagent Strips 2 Parameter(Albumin & Sugar) (1X100) ( (Isi/Iso/Ce Certified)) Rate Per Pack Of 100 Strips , Multisticks Urine Analysis Reagent Strips 10 Parameter ( (Isi/Iso/Ce Certified)) Rate Per Pack Of 100 Strips , Multisticks Urine Analysis Reagent Strips 10 Parameter Bayer ( (Isi/Iso/Ce Certified)) Rate Per Pack Of 100 Strips , Vaccuame Needle ( (Isi/Iso/Ce Certified)) , Vaccutainers Sodium Citrate 3.2% (2.7 Ml) (Non - Vaccum)A Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainer Gel Yellow Cap,A Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainer Lithium Heparin (Green Top) Tube (Non-Vaccum) 6 Ml A Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainer Lithium Heparin (Green Top) Tube (Vaccum) 3 Mla Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainer Needle ( (Isi/Iso/Ce Certified)) , Vacutainer Needle Holder ( (Isi/Iso/Ce Certified)) , Vacutainer Safety-Lok Pediatric Blood Collection Set With Pre-Attached Holder ( (Isi/Iso/Ce Certified)) , Vacutainer Sodium Heparin (Green Top) Tube (Non-Vaccum) 3 Ml A Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainer Sodium Heparin (Green Top) Tube (Non-Vaccum) 6 Ml A Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainer Stretch Torniquet ( (Isi/Iso/Ce Certified)) , Vacutainer Tubes Purple/Lavender Topped (K2 Edta) 2 Ml Capacity (Size Of Tube:13 X 75Mm), Vaccum Based Tubea Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainer Tubes Violet/Purple/Lavender Topped (K2 Edta) 0.5 Ml Capacity (Size Of Tube:12 X 55/56 Mm), Screw Cap Pediatric Microtainer/Microcapillary/Mini Blood Collection Tubea Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainer Tubes Violet/Purple/Lavender Topped (K2 Edta) 1 Ml Capacity (Size Of Tube:12 X 55/56 Mm), Screw Cap Pediatric Microcapillary/Mini Blood Collection Tubea Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainer Tubes Violet/Purple/Lavender Topped (K2 Edta) 1.3 Ml Capacity (Size Of Tube:12 X 55/56 Mm), Screw Cap Pediatric Microcapillary/Mini Blood Collection Tube A Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainers Edta (Non -Vaccum) A Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainers Edta (Vaccum Tubes) A Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainers Florides (Vaccum Tubes) A Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainers Plain /Clot Activator A Pack Of 1X100 (Vaccum Tubes) ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainers (For Pus Collection) Rate Per Vacutainer(Isi/Iso/Ce Certified) , Vacutainers Plain /Clot Activator A Pack Of 1X100 ( Non-Vaccum Tubes) ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainers Sodium Citrate (Vaccum Tubes, ) (For Esr 1.6 Ml)( Black Top) A Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainers Sodium Citrate 3.2% (2.7 Ml) (Vaccum Tubes) A Pack Of 1X100 (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainers Sodium Citrate 3.8% (Black Top)Vaccum Tube A Pack Of 1X100 ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vacutainers Sodium Citrate 3.8% (Black Top) Tube A Pack Of 1X100 ( Non-Vaccum Tubes) ( (Isi/Iso/Ce Certified)) Rate Per Pack , Vdrl (Syphilis Kit Elisa 96 Test) ( (Isi/Iso/Ce Certified)) Rate Per Kit , Vdrl (Syphilis Kit Elisa 96 Test) (J. Mitra/ Erba/Abbot/ Cal Biotech/ Other Branded/ Sd Bio Sensor)Rate Per Kit , Vdrl Strips A Pack Of 100 Strips (Isi/Iso/Ce Certified)) Rate Per Strip , Vdrl Rapid Card( (Isi/Iso/Ce Certified)) Rate Per Card , Vtm Kit With Oral And Nasal Swab Pair (As Per Icmr Guidelines) Rate Per Vtm Kit , Vtm Media Rate Per Single Piece , Vtm Vial Rack , Wash Bottles Glass 500Ml Rate Per Bottle , Wash Bottles Plastic 500Ml Rate Per Bottle , Water Sample Bottles Glass 250Ml Rate Per Bottle , Water Sample Bottles Glass (Borosil) 250Ml Rate Per Bottle , Water Sample Bottles Glass 500Ml Rate Per Bottle , Water Sample Bottles Glass (Borosil)500Ml Rate Per Bottle , Wbc Diluting Fluid 100 Ml ( (Isi/Iso/Ce Certified)) , White Petroleium Jelly 100 %20 Gm Jar( (Isi/Iso/Ce Certified)) , White Petroleium Jelly 100 % 500 Gm Jar( (Isi/Iso/Ce Certified)) , Widal Kit 5X4 Ml ( (Isi/Iso/Ce Certified))Rate Per Kit , Wooden Tips 6 A Pack Of 1X100 Rate Per Pack , Xylene 1X500ml ( (Isi/Iso/Ce Certified)) Rate Per Pack , Auto Analyser Thermal Paper Role (57 Mmx30m) (Erba) , Automated Extraction Kits (For Thermo Scientifix For Kingfisher Flex Automated Extraction System ,96 Well) Rt-Pcr Lab , Autoclave Biohazard Bag (12X24) ( (Isi/Iso/Ce Certified)) Rate Per Pack Of 1X100 , Autoclave Biohazard Bag (14X19) ( (Isi/Iso/Ce Certified) Rate Per Pack Of 1X100 , Autoclave Biohazard Bag (24X30) ( (Isi/Iso/Ce Certified) Rate Per Pack Of 1X100 , Cryo Vails 1.8 Ml A Pack Of 1X1000 (Tarson) Rate Per Pack Of 1X1000 , Cryo Marker ( (Isi/Iso/Ce Certified)) , Cryo Tags A Pack Of 1X1000 (Tarson) Rate Per Pack Of 1000 , Film Applicator , Genemag Viral Dns/Rna Purification Kit (400 Plate 96 Preps) Rate Per Box , Mct Rack (Tarson) Rate Per Rack , Microseal B Adhesive Seal (Pcr Seal) Biorad ( Rate Of Single Piece) , Pcr Cap Strips A Pack Of 1X120 (Bio-Rad)( Rate Per Pack Of 1X120 ) , Pcr Plates A Pack Of 1X50 (Bio-Rad , Plastic Case Mounted ) ( Rate Of Pack Of 1X50) , Pcr Seals A Pack Of 1X100 (Bio-Rad ) ( Rate Per Pack Of 1X100 )) , Pcr Tube Strips (Bio-Rad) A Pack Of 1X120( Rate Of Pack 1X120) , Qpcr Adhesive Seal ( Thermo / Brand /Biolinkk /Ils) ( Rate Of Single Piece) , Qpcr Plates 96 Well ( Thermo /Brand/ Biolinkk /Ils) , Racked Sterile Filtered Microtips(Low Retention) 1000Ul Tarson Rate Per Box Of 1X960 , Racked Sterile Filtered Microtips(Low Retention) 100Ul Tarson Rate Per Box Of 1X960 , Racked Sterile Filtered Microtips(Low Retention) 10Ul/20Ul Tarson Rate Per Box Of 1X960 , Racked Sterile Filtered Microtips(Low Retention) 200Ul Tarson Rate Per Box Of 1X960 , Rt-Pcr Kits 96 Well Plate (Bio Rad) Rate Per Box , Thermal Printing Roll For Urine Analyzer And Cbc 57/58Mm Size Rate Per Roll , Thermol Roll 57Mm ,50Mm Rate Per Roll , Plastic Pallet ,Hdpe, Size(1200*1000*60 Mm) ( (Isi/Iso/Ce Certified)) , Pm Kit For Di Plant 7-10 Liter Per Hr (Model: 165935) , Am Kit For Di Plant (Model: 165935) , Pm Kit For Em200 , Elite 580 Calibrator 1X3 Ml , 4 Channel Ise Cleaning Solution - 5421 (6X12ml) (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Reagent Pack @35 Spd Cal A-520 Ml/ Cal B-190 Ml (Total 710 Ml)(Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Ada1 X 20 Ml/1 X 10 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Ada Cali1 X 1 M L (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Ada Control1 X 1 Ml(Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Albumin 5 X 22 Ml(Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Alkaline Phosphatase5 X 22 Ml/5X 6.8 Ml(Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Amylase 5X11 Ml(Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Bilirubin Direct 5 X 22 Ml/5X 6.8 Ml(Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Bilirubin Direct Plus 6 X 44 Ml/6 X 12.3 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Bilirubin Total 5 X 22 Ml/5X 6.8 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Bilirubin Total Plus 6 X 44 Ml/6 X 12.3 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Calcium (A) 5 X 6 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Chloride 10 X 12 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Cholesterol 5 X 11 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Ck Mb 2 X 12 Ml/2X 3 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Ck Nac 2 X 12 Ml/2X3 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Control H (Aso/Rf/Crp) 1 X 1 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Control L (Aso/Rf/Crp) 1 X 1 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Creatinine-Enzymatic 5 X 30 Ml /5 X 10 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Creatinine-Jaffe 5 X 44 Ml/5X 11 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Erba Autowash - System Pack 10 X 100 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Erba Norm 4 X 5 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Erba Path 4 X 5 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Fe 125 R1-4 X 25 Ml, R2-2 X 12.5 Ml Calibrator: 2 X 2 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Ferritin 2 X 14.5/2 X 7.7 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Ferritin Calibrator 1 X 1 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Ferritin Control High 1 X 1 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Ferritin Control Low 1 X 1 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Gamma Gt 2 X 22 Ml / 2 X 6.8 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Glucose (God-Pod) 10 X 44 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Glucose Hexokinase - Uv 5 X 44 Ml/5X 12.5 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Hba1c Cali Set 5 X 0.5 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Hba1c Con H 1X 0.5 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Hdl Cholesterol With Calibrator 4 X 30 Ml/4 X 10 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Ldh P 2 X 44 Ml/2X 11 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Ldl Cholesterol With Calibrator 2 X 30 Ml/2X 10 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Lipase Xl 1 X 44 Ml/1X 11 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Magnesium 2 X 44 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Micro Albumin Control 1 X 1 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Micro Albumin With Cal 1 X 5 Ml/2X 25 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Microprotein With Cal 5 X 6 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Phosphorus 5 X 6 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Sgot El Mini 2X 22 Ml/2X 6.9 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Sgot-Hl Small System Pack 5 X 22 Ml/5X 11.7 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Sgpt-El Mini 2 X 22 Ml/2X 6.9 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Sgpt Hl Small System Pack 5 X 22 Ml/5X 11.7 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Total Protein 10 X 44 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Total Protein (Two Reagents) 4 X 34 Ml/4 X 17 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Total Protein Small System Pack 5 X 6 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Triglycerides - 5X 11 Ml/5X4 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Uibc 125R 1-4 X 25 Ml, R 2-2 X 12.5 Ml,Calibrator: 2X 2 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Urea 5 X 44 Ml/5X 11 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Uric Acid 5 X 22 Ml/5X 6.8 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Xl Aso Turbilatex Withcalibrator (Ita) 1 X 22 Ml/1X 5.5 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Xl-Autowash Ac/Al Kit5 X 44 Ml/5 X 44 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Xl-Multical4 X 3 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Xl-Rf Turbilatex Withcalibrator (Ita) 1 X 22 Ml/1X 5.5 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Xl-Crp-Turbilatex Withcalibrator (Ita) 2 X 22 Ml/2X 6.7 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Xl Hba1c With Cali Set2 X 15 Ml/2 X 5 Ml (Biochemistry Reagent For Transasia / Erba Machine Model :- Em200 ) , Blood Diluent 20 Litre (For Fully Automated Five Part Heaematology Analyser Meril Diagnostics Machine Model- Merilyzer Celquant 5 Plus , Fbh Lyse 500Ml (For Fully Automated Five Part Heaematology Analyser Meril Diagnostics Machine Model- Merilyzer Celquant 5 Plus , Fdti Lyse 500Ml (For Fully Automated Five Part Heaematology Analyser Meril Diagnostics Machine Model- Merilyzer Celquant 5 Plus , Fdoi Lyse 500Ml (For Fully Automated Five Part Heaematology Analyser Meril Diagnostics Machine Model- Merilyzer Celquant 5 Plus , Cbiquant- 5 Detergent 4X100ml (For Fully Automated Five Part Heaematology Analyser Meril Diagnostics Machine Model- Merilyzer Celquant 5 Plus , Control Level-1 , 2.5Ml (For Fully Automated Five Part Heaematology Analyser Meril Diagnostics Machine Model- Merilyzer Celquant 5 Plus , Cbc Detergent Fluid (Urit-2900) , Cbc Diluent 20 Ltr (Urit-2900) , Cbc Lytic Fluid (Urit-2900) , Cbc Proclennor (Urit-2900) , Cleaner For Cell Counter Erba H-360, 50Ml. , Elisa Washer (Erba) , Elite H Clean, 50 Ml ( Transasia Erba Machine Model - Elite 580 , Proprietry) , Elite H5 Control H (3Ml) ( Transasia Erba Machine Model - Elite 580 , Proprietry) , Elite H5 Control L (3Ml) ( Transasia Erba Machine Model - Elite 580 , Proprietry) , Elite H5 Control N (3Ml)( Transasia Erba Machine Model - Elite 580 , Proprietry)) , Elite H580 Diluent, 20Litres ( Transasia Erba Machine Model - Elite 580 , Proprietry) , Elite H580 Lyse 1, 500Ml ( Transasia Erba Machine Model - Elite 580 , Proprietry) , Elite H580 Lyse 2, 500Ml ( Transasia Erba Machine Model - Elite 580 , Proprietry)) , Elite H580 Lyse 3, 1Litres ( Transasia Erba Machine Model - Elite 580 , Proprietry) , Embedded O Rings 20Pieces (Erba) , Erba Calcium Chloride For Ecl 105 , Erba D-Dimer Calibrator Kit For Ecl 105 , Erba D-Dimer Kit For Ecl 105 , Erba Norm Kit , Erba Path Kit , Erba Protime Ls For Ecl 105 , Erba Single Reaction Cuvettes For Ecl 105 , Lyse For Cell Counter Erba H-360, 500Ml , Urinorm Controls (High, Low, Normal) For Erba Laura Urine Analyzer , Procleaner For C,B,C (Erba) , Quality Control Norm (For Semi Automatic Auto Analyser Erba) , Quality Control Path (For Semi Automatic Auto Analyser Erba) , Tissue Paper Lint Free Rate Per Roll , Hub Cutter Non Electrical Stainless Steel , Hub Cutter With Sharp Container Of 1 Lt Capacity Cutting Life Of Blade Is 5000 Minimum Ats. Blade Is Made Of Stainless Steel (156911 Of 1992) Thickness Of Blade Should Be 0.5 Mm {Astha} , O2 Flow Meter With Bottle (Isi/Iso/Ce Certified) , Nebulizers : A 120V, 60Hz Mono- Phase Electrical Source With Line Connection Plug Nema 5-15 Type. Protections Against Over-Voltage And Over-Current Line Conditions. {Bpl/Omron/Beurer} , Oxygen Flow Meter With Humidifier Bottle :Chromium Plated Brass Body, Metering Tube And Cover Made Of Polycarbonate Body, Flow Adjustment By Needle Valve Equipped With Inlet Filter-100 Um, Flow Rate 0-15 Liters Per Minute, Flush Flow 60 Litres Per Minute, Flow Read By The Centre Of The Ball, Inlet Pressure 60Psi; Humidifier Bottle: Lid Made Of Abs Plastic, Jar Made Of Unbreakable Poly Carbonate, Valve Pressure Brass Chromium Plated, It Should Be Steam Autoclaved/Gas Sterilized , Regular Stethoscope (Microtone) : Stethoscope Of Standard Size,Chromium Plated Metal Binaural, V Rubber Tube In One Piece. Rotating Piper Fitting For Both Flip Functions. , Stethoscope Daimond , Stethoscope Neonatal (Microtone) , Stethoscope Pediatric (Microtone) , Vtm Vial Rack (Tarson) Rate Per Rack , Waste Bag Sealing Ties , Weighing Machine Adult Manual Krups/ Suvrna , Weighing Machine Adult Digital {Bpl/Omron , B P Appartus Digital ( Omron ) , B P Appartus Digital ( Bpl) , B P Instrument( Conventinal, Led, Mercury Free) ( (Isi/Iso/Ce Certified)) , B P Instrument( Deluxe, Dial Type With Cuff ) ( Diamond) , B P Instrument( Clock Type Dial Size 6X6 Inch , Model -Bpdl237 ) ( Diamond Only) , Clinical Thermometer ,Oval ( (Isi/Iso/Ce Certified)) , Clinical Thermometer ,Digital ( Accusure) , Rectal Thermometer ,Prismatic ( (Isi/Iso/Ce Certified)) , Emergency First Aid Resucitation Kit) ( Adult) ( (Isi/Iso/Ce Certified)) , Emergency First Aid Resucitation Kit) ( Paediatric) ( (Isi/Iso/Ce Certified)) , First Aid Medicine Storage Box/Emergency Medical Box ,Plastic,Emergency Cabinet Oragniser ,Detachable Tray Medical Box& Partition Tray For Segregation, Item Package Quantity 6,White&Red Combination With Plus Sign Medicine Organiser,Handle With Lock (23.6Cm*15.3Cm*14Cm) ( (Isi/Iso/Ce Certified)) , First Aid Medico Box ,Plastic,Multiutility Storage Box With Handle, White, Closure Type Lock (235Cm*16Cm*14Cm) ( (Isi/Iso/Ce Certified)) , Height Measuring Scale(Floor Model Without Weighing Scale) ( (Isi/Iso/Ce Certified)) , Height Measuring Scale(Floor Model With Digital Weighing Scale) , Height Measuring Scale(Floor Model With Mechanical Weighing Scale) ( (Isi/Iso/Ce Certified)) , Height Measuring Scale(Wall Mounted) ( (Isi/Iso/Ce Certified)) , Home Isolation Kit Bag ( (Isi/Iso/Ce Certified)) , Infant Resuscitation Kit (Autoclavable ,Resuable,Infant Resuscitator&250Ml Silicone Bellow With Non Rebreathing Valve&Mask Size 00,01&360 Degree Swiveling Patient Connector With Standard 15 Mm/22Mm Diameter&Corrugated Pvc Oxygen Reservoir& 1.5 Metres Pvc Oxygen Tubing ( (Isi/Iso/Ce Certified)) , Infantometer(Height Measuring Scale Infant) ( (Isi/Iso/Ce Certified)) , Dcp Small Plate: 3.5Mm: All Holes Ss , Dcp Narrow Plate: 4.5Mm: All Holes Ss , Dcp Broad Plate: 4.5Mm: All Holes Ss , Dcp Small Reconstruction Plate: 3.5Mm: All Holes Ss , Dcp Reconstruction Plate: 4.5Mm: All Holes Ss , Dcp Small Reconstruction Plate-Curved: 3.5Mm: All Holes Ss , Lc-Dcp Small Plate:3.5Mm: All Holes Ss , Lc-Dcp Narrow Plate:4.5Mm: All Holes Ss , 5/8 Ring-100,120,140, 160Mm, Ss , 5/8 Ring-180,200,220,240,260Mm, Ss , annual periodical maintenance (Austinmooresprosthesis) Non-Sterile, [37Mmto55mm], Ss , annual periodical maintenance (Austinmooresprosthesis) Sterile, [37Mmto55mm], Ss , Bipolar Prosthesis [Non-Fenestrated]Sterile,[37Mmto55mm], Ss , Bipolar Prosthesis[Fenestrated]Sterile,[37Mmto55mm], Ss , Blade -50,60,70,80,90,100Mm, Degree-90º,100º,110º,120º,130º:, Ss , Boxes Panner, Ss , Bushing-20Mm, Ss , C.C.Screw 4.0Mmxf.Th.-,10Mmto60mm Ss , C.C.Screw 4.0Mmxp.Th.-,10Mmto60mm Ss , C.C.Screw 6.5Mm/7.0Mmx16th.-,40Mmto120mm Ss , C.C.Screw6.5Mm/7.0Mmxf.Th.-,40Mmto120mm Ss , Cancellous Schanz Pin6.5Mmx16th./32Th.-225Mm, Ss , Cancellous Screw 3.5Mm-,10Mmto50mm Ss , Cancellous Screw 4.0Mmxf.Th.-,10Mmto60mm Ss , Cancellous Screw 4.0Mmxp.Th.-,10Mmto60mm Ss , Cannulated Dril Lbit 125Mm-2.7,3.2Mm, Ss , Cannulated Drill Bit 225Mm-4.0,4.5Mm, Ss , Carbon Fiber Ring 100-240 Ss , Circlage Wire With Loop[16,18,20Gauge]-300Mm, Ss , Connecting Clamp, Ss , Connection Bolt-20Mm, Ss , Connection Plate With Threaded End All Holes, Ss , Cortical Screw 2.7Mm-,10Mmto30mm (Selftapping) Ss , Cortical Screw 4.5Mm-,All Sizes (Selftapping) Ss , Cortical Screw3.5Mm-,All Sizes (Selftapping) Ss , Curved Plate- All Sizes, Ss , Danham Pin(Centrallythreaded)4.5/5.0-225Mm, Ss , Dc T Plate: 4.5Mm:,All Sizes Ss , Dcp Angled Blade Plate For Intertrochantric Osteotomies:, Ss , Dcp Angled Blade Plate130ºblade:50,60,70,80,90,100Mm:,All Holes Ss , Dcp Calcaneal Plate: 3.5Mm: All Sizes Ss , Dcp Condylar Buttress Plate: 4.5Mm:(L/R): All Holes Ss , Dcp Condylar Plate9 5ºblade:50/60/70/80Mm: All Sizes Ss , Dcp Narrow Plate: 4.5Mm: All Sizes, Ss , Dcp Lateral Tibia Head Buttress Plate (L/R):4.5Mm: All Sizes Ss , Dcp Semi Tubular Plate: 4.5Mm: All Sizes Ss , Dcp Small Hook Plate:3.5Mm: All Sizes Ss , Dcp Small Plate: 3.5Mm:, All Sizes Ss , Dcp Small Reconstruction Plate: 3.5Mm: All Sizes Ss , Dcp Small Reconstruction Plate-Curved: All Sizes Ss , Dcp Small Tplate Oblique Angled: 3.5Mm:,All Sizes Ss , Dcp Small Tplate R/A: 3.5Mm: All Sizes Ss , Dcp1/3Rd Tubular Plate: 3.5Mm:,All Sizes Ss , Dcpl Buttress Plate: 4.5Mm:(L/R):,All Sizes Ss , Dcpt Plate: 4.5Mm: All Sizes Ss , Dcpy Reconstruction Plate: 3.5Mm:, All Sizes Ss , Dcs Barrel Plate95º:4.5Mm: All Holes Ss , Dhs Barrel Plate 130º/135º:L/B&S/B:4.5Mm: All Sizes Ss , Dhss Crew With Compression Screw, All Sizes Ss , Distractor 6.0Mm [150Mm,200,250Mm], All Sizes Ss , Double Pin Clamp (Deluxe), Ss , Drill Bit Plain All Sizes Ss , Drill Bit Quickcoupling All Sizes Ss , Drummond Wire All Sizes Ss , Dynametric Wire Tensioner, Ss , Elastic Nail All Sizes Ss , Enders Nail All Sizes Ss , Endobutton With Loop-Sterile All Sizes Ss , Endobutton, All Sizes Ss , Enders Nail All Sizes Ss , Helical Blade (Pfna-Ii):, All Sizes Ss , Herbert Screw Cannulated All Sizes Ss , Guide Wire- All Sizes Ss , Half Ring- All Sizes Ss , Hinge-Male,Female&90º, All Sizes Ss , Ilizarow K Wire Bayonet Point, All Sizes Ss , Instruments Set For Acl/Pcl Reconstruction, All Sizes Ss , Instruments Setwith Boxfor Herbert Screw, All Sizes Ss , Interference Screw-Cannulated All Sizes Ss , Interlocking Exper Tibia Nail, All Sizes Ss , Interlocking Humerus Nail: All Sizes Ss , Interlocking Sirus Femur Nail, All Sizes Ss , Interlocking Bolt All Sizes Ss , Interlocking Expert Humerus Nail:,[Cannulated] All Sizes Ss , Interlocking Expert Tibia Nail, All Sizes Ss , Interlocking Femur Nail,[Cannulated] All Sizes Ss , Interlocking Femur Nail, All Sizes Ss , Interlocking Guide Wire, All Sizes Ss , Interlocking Long Proximal Femur Nail135º[Left]/[Right], All Sizes Ss , Interlocking Short Proximal Femur Nail (Pfn) 130º/135º, All Sizes Ss , Interlocking Supra Condylar Nail Angled, All Sizes Ss , Interlocking Tibial Nail, All Sizes Ss , Interlocking Trochantric Proximal Femurnail (Tfn)135º, All Sizes Ss , Italian annual rate contract All Sizes Ss , K. Nail (Straight)- All Sizes Ss , K. Nail(Bent)- All Sizes Ss , K. Wire Double Ended Non Sterile All Sizes Ss , Lc-Dc Broad Plate: All Sizes Ss , Lc-Dcp Narrow Plate: All Sizes Ss , Lc-Dcp Small Plate:3.5Mm:, All Sizes Ss , Locking 1/3Rd Tubular Plate:3.5Mm:, All Sizes Ss , Locking Anterolateral Distal Tibial Plate:(L/R):, All Sizes Ss , Locking Broad Plate: 4.5/5.0Mm:, All Sizes Ss , Locking Calcaneal Plate: D Type:(L/R):, All Sizes Ss , Locking Calcaneal Plate: P Type:(L/R):, All Sizes Ss , Locking Calcaneal Plate:(L/R):, All Sizes Ss , Locking Cancellous Screw 3.5Mmxf.Th.-, All Sizes Ss , Locking Cancellous Screw 5.0Mmxf.Th.-, All Sizes Ss , Locking Clavicle Hook Plate: 3.5Mm:(L/R): All Sizes Ss , Locking Curved Reconstruction Plate (Roundhole):3.5Mm:, All Sizes Ss , Locking Curved Reconstruction Plate: 3.5Mm:, All Sizes Ss , Locking Dhs Barrel Plate All Sizes Ss , Locking Distal Femu Rplate:(L/R):, All Sizes Ss , Locking Distal Fibula Plate: 3.5Mm:, All Sizes Ss , Locking Distal Humerus Plate Dorsolatera With Support: 2.7/3.5Mm:(L/R), All Sizes Ss , Locking Distal Humerus Plate Dorsolateral:2.7/3.5Mm:(L/R):, All Sizes Ss , Locking Distal Humerus Plate Medial:2.7/3.5Mm:(L/R):, All Sizes Ss , Locking Distal Radius (Head4/5Hole)Volarplate:2.7Mm/3.5Mm:(L/R): All Sizes Ss , Locking Distal Radius Volar Plate:3.5Mm:(L/R):, All Sizes Ss , Locking Extra-Articular Distal Humerus Plate:3.5Mm:(L/R):, All Sizes Ss , Locking Lateral Distal Fibula Plate:(L/R):, All Sizes Ss , Locking Lateral Tibial Plate:(L/R):, All Sizes Ss , Locking L-Buttress Plate: 4.5/5.0Mm: All Sizes Ss , Locking Medial Distal Tibial Plate With Tab:(L/R):, All Sizes Ss , Locking Medial Distal Tibial Plate:(L/R):, All Sizes Ss , Locking Medial Proximal Tibia Plate 3.5Mm:(L/R): All Sizes Ss , Locking Medial Proximal Tibial Plate5.0Mm:(L/R): All Sizes Ss , Locking Narrow Plate: 4.5/5.0Mm:, All Sizes Ss , Locking Olecranon Plate: 3.5Mm:(L/R): All Sizes Ss , Locking Pelvic Curved Plate: 3.5Mm: All Sizes Ss , Locking Pelvic Plate: 3.5Mm: All Sizes Ss , Locking Philos Plate: 3.5Mm: All Sizes Ss , Locking Postero Medial Proximal Tibial Plate: All Sizes Ss , Locking Posterolateral Distal Fibula Plate:(L/R): All Sizes Ss , Locking Proximal Femur Plate:4.5/5.0Mm:(L/R): All Sizes Ss , Locking Proximal Humerus Plate:3.5Mm:, All Sizes Ss , Locking Proximal Tibia Plate 3.5Mm(Ztype):(L/R): All Sizes Ss , Locking Proximal Tibia Plate 3.5Mm:(L/R): All Sizes Ss , Locking Proximal Tibia Plate 5.0Mm:(L/R): All Sizes Ss , Locking S-Clavicle Plate With Lateral Extension: 2.7/3.5Mm:(L/R):, All Sizes Ss , Locking S-Clavicle Plate: 3.5Mm:(L/R):, All Sizes Ss , Locking Screw 2.7Mm(S.T.)-, All Sizes Ss , Locking Screw 3.5Mm(S.T.)-, All Sizes Ss , Locking Screw 5.0Mm(S.T.)-, All Sizes Ss , Locking Small Plate: 3.5Mm:, All Sizes Ss , Locking Small Tplate Obliqueangeled:3.5Mm:(L/R): All Sizes Ss , Locking Small Tplate Rightangeled:3.5Mm:, All Sizes Ss , Locking Straight Reconstruction Plate (Roundhole):3.5Mm:, All Sizes Ss , Locking Straight Reconstruction Plate:3.5Mm:, All Sizes Ss , Locking T-Buttress Plate: 4.5/5.0Mm: All Sizes Ss , Locking Tomo Fix Medial High Medial Plate (Osteotomy):3.5Mm:, All Sizes Ss , Malleolar Screw3.5Mm-, All Sizes Ss , Malleolar Screw4.5Mm-, All Sizes Ss , Mechanical Wire Tensioner, All Sizes Ss , Modular Bipolar Cup [Collar+3,0,-3], [Ball - All Sizes Ss , Modular Bipolar Stem [Small,Medium,Large], All Sizes Ss , Multipin Clamp, All Sizes Ss , Nut, All Sizes Ss , Nylonnut, All Sizes Ss , Olive Wire 400Mm, All Sizes Ss , Open Single Pin Clamp, All Sizes Ss , Paediatric Dhs Barrel Plate: 3.5Mm:, All Sizes Ss , Paediatric Dhss Crew With Compression Screw, All Sizes Ss , Pfn Bolt6.5Mm-, All Sizes Ss , Pfnbolt8.0Mm-, All Sizes Ss , Post Male/Female- All Sizes Ss , Proxima Femur Nail Antirotation (Pfna -Ii):Short:, All Sizes Ss , Proximal Femur Nail Antirotation (Pfna-Ii):Long:(L/R):, All Sizes Ss , Rush Nai All Sizes Ss , S.S. Wire-16,18,20,22,24Gauge, All Sizes Ss , Scahnz Pin All Sizes Ss , Schanz Pin Bolt, All Sizes Ss , Schanz Pin Introducer, All Sizes Ss , Single Pin Clamp (Deluxe), All Sizes Ss , Single Pin Clamp (Ordinary), All Sizes Ss , Sirus Nail Bolt All Sizes Ss , Small Spanner, All Sizes Ss , Spacing Washer, All Sizes Ss , Spiked Ligament Staple [Small&Large], All Sizes Ss , Spiked Ligament Washer, All Sizes Ss , Square Nail [Radius/Ulna] All Sizes Ss , Steinman Pin All Sizes Ss , Straight Plate All Sizes Ss , Suture Dis Cwasher, All Sizes Ss , Suture Discwith -Regular, All Sizes Ss , Suture Discwith -Conical, All Sizes Ss , Telescopic Rod All Sizes Ss , Thompsons Prosthesis Non-Sterile, All Sizes Ss , Thompsons Prosthesis Sterile, All Sizes Ss , Threaded Guide Wire- All Sizes Ss , Threaded K. Wire Double Ended - All Sizes Ss , Threaded Rod- All Sizes Ss , Threaded Rod-Slotted- All Sizes Ss , Threaded Socket- All Sizes Ss , Tibial Post Fixation Screw All Sizes Ss , Transverse Clamp, All Sizes Ss , Triple Trocarset, All Sizes Ss , Tubeto Tube Clamp, All Sizes Ss , Tubular Rod(Perinchrate), All Sizes Ss , Twin Adjustable Clamp-Curved, All Sizes Ss , Twin Adjustable Clamp-Straight, All Sizes Ss , Twisted Plate- All Sizes Ss , Washer (Slotted), All Sizes Ss , Wire Fixation Bolt-Slotted & Cannulated, All Sizes Ss , Wrenchoqube All Sizes Ss , K Wire Sterile Double All Sizes Ss , Dcp Small Plate: 3.5Mm: All Holes Titanium , Dcp Narrow Plate: 4.5Mm: All Holes Titanium , Dcp Broad Plate: 4.5Mm: All Holes Titanium , Dcp Small Reconstruction Plate: 3.5Mm: All Holes Titanium , Dcp Reconstruction Plate: 4.5Mm: All Holes Titanium , Dcp Small Reconstruction Plate-Curved: 3.5Mm: All Holes Titanium , Lc-Dcp Small Plate:3.5Mm: All Holes Titanium , Lc-Dcp Narrow Plate:4.5Mm: All Holes Titanium , 5/8 Ring-100,120,140, 160Mm, Titanium , 5/8 Ring-180,200,220,240,260Mm, Titanium , annual periodical maintenance (Austinmooresprosthesis) Non-Sterile, [37Mmto55mm], Titanium , annual periodical maintenance (Austinmooresprosthesis) Sterile, [37Mmto55mm], Titanium , Bipolar Prosthesis [Non-Fenestrated]Sterile,[37Mmto55mm], Titanium , Bipolar Prosthesis[Fenestrated]Sterile,[37Mmto55mm], Titanium , Blade -50,60,70,80,90,100Mm, Degree-90º,100º,110º,120º,130º:, Titanium , Boxes Panner, Titanium , Bushing-20Mm, Titanium , C.C.Screw 4.0Mmxf.Th.-,10Mmto60mm Titanium , C.C.Screw 4.0Mmxp.Th.-,10Mmto60mm Titanium , C.C.Screw 6.5Mm/7.0Mmx16th.-,40Mmto120mm Titanium , C.C.Screw6.5Mm/7.0Mmxf.Th.-,40Mmto120mm Titanium , Cancellous Schanz Pin6.5Mmx16th./32Th.-225Mm, Titanium , Cancellous Screw 3.5Mm-,10Mmto50mm Titanium , Cancellous Screw 4.0Mmxf.Th.-,10Mmto60mm Titanium , Cancellous Screw 4.0Mmxp.Th.-,10Mmto60mm Titanium , Cannulated Dril Lbit 125Mm-2.7,3.2Mm, Titanium , Cannulated Drill Bit 225Mm-4.0,4.5Mm, Titanium , Carbon Fiber Ring 100-240 Titanium , Circlage Wire With Loop[16,18,20Gauge]-300Mm, Titanium , Connecting Clamp, Titanium , Connection Bolt-20Mm, Titanium , Connection Plate With Threaded End All Holes, Titanium , Cortical Screw 2.7Mm-,10Mmto30mm (Selftapping) Titanium , Cortical Screw 4.5Mm-,All Sizes (Selftapping) Titanium , Cortical Screw3.5Mm-,All Sizes (Selftapping) Titanium , Curved Plate- All Sizes, Titanium , Danham Pin(Centrallythreaded)4.5/5.0-225Mm, Titanium , Dc T Plate: 4.5Mm:,All Sizes Titanium , Dcp Angled Blade Plate For Intertrochantric Osteotomies:, Titanium , Dcp Angled Blade Plate130ºblade:50,60,70,80,90,100Mm:,All Holes Titanium , Dcp Calcaneal Plate: 3.5Mm: All Sizes Titanium , Dcp Condylar Buttress Plate: 4.5Mm:(L/R): All Holes Titanium , Dcp Condylar Plate9 5ºblade:50/60/70/80Mm: All Sizes Titanium , Dcp Narrow Plate: 4.5Mm: All Sizes, Titanium , Dcp Lateral Tibia Head Buttress Plate (L/R):4.5Mm: All Sizes Titanium , Dcp Semi Tubular Plate: 4.5Mm: All Sizes Titanium , Dcp Small Hook Plate:3.5Mm: All Sizes Titanium , Dcp Small Plate: 3.5Mm:, All Sizes Titanium , Dcp Small Reconstruction Plate: 3.5Mm: All Sizes Titanium , Dcp Small Reconstruction Plate-Curved: All Sizes Titanium , Dcp Small Tplate Oblique Angled: 3.5Mm:,All Sizes Titanium , Dcp Small Tplate R/A: 3.5Mm: All Sizes Titanium , Dcp1/3Rd Tubular Plate: 3.5Mm:,All Sizes Titanium , Dcpl Buttress Plate: 4.5Mm:(L/R):,All Sizes Titanium , Dcpt Plate: 4.5Mm: All Sizes Titanium , Dcpy Reconstruction Plate: 3.5Mm:, All Sizes Titanium , Dcs Barrel Plate95º:4.5Mm: All Holes Titanium , Dhs Barrel Plate 130º/135º:L/B&S/B:4.5Mm: All Sizes Titanium , Dhss Crew With Compression Screw, All Sizes Titanium , Distractor 6.0Mm [150Mm,200,250Mm], All Sizes Titanium , Double Pin Clamp (Deluxe), Titanium , Drill Bit Plain All Sizes Titanium , Drill Bit Quickcoupling All Sizes Titanium , Drummond Wire All Sizes Titanium , Dynametric Wire Tensioner, Titanium , Elastic Nail All Sizes Titanium , Enders Nail All Sizes Titanium , Endobutton With Loop-Sterile All Sizes Titanium , Endobutton, All Sizes Titanium , Enders Nail All Sizes Titanium , Helical Blade (Pfna-Ii):, All Sizes Titanium , Herbert Screw Cannulated All Sizes Titanium , Guide Wire- All Sizes Titanium , Half Ring- All Sizes Titanium , Hinge-Male,Female&90º, All Sizes Titanium , Ilizarow K Wire Bayonet Point, All Sizes Titanium , Instruments Set For Acl/Pcl Reconstruction, All Sizes Titanium , Instruments Setwith Boxfor Herbert Screw, All Sizes Titanium , Interference Screw-Cannulated All Sizes Titanium , Interlocking Exper Tibia Nail, All Sizes Titanium , Interlocking Humerus Nail: All Sizes Titanium , Interlocking Sirus Femur Nail, All Sizes Titanium , Interlocking Bolt All Sizes Titanium , Interlocking Expert Humerus Nail:,[Cannulated] All Sizes Titanium , Interlocking Expert Tibia Nail, All Sizes Titanium , Interlocking Femur Nail,[Cannulated] All Sizes Titanium , Interlocking Femur Nail, All Sizes Titanium , Interlocking Guide Wire, All Sizes Titanium , Interlocking Long Proximal Femur Nail135º[Left]/[Right], All Sizes Titanium , Interlocking Short Proximal Femur Nail (Pfn) 130º/135º, All Sizes Titanium , Interlocking Supra Condylar Nail Angled, All Sizes Titanium , Interlocking Tibial Nail, All Sizes Titanium , Interlocking Trochantric Proximal Femurnail (Tfn)135º, All Sizes Titanium , Italian annual rate contract All Sizes Titanium , K. Nail (Straight)- All Sizes Titanium , K. Nail(Bent)- All Sizes Titanium , K. Wire Double Ended Non Sterile All Sizes Titanium , Lc-Dc Broad Plate: All Sizes Titanium , Lc-Dcp Narrow Plate: All Sizes Titanium , Lc-Dcp Small Plate:3.5Mm:, All Sizes Titanium , Locking 1/3Rd Tubular Plate:3.5Mm:, All Sizes Titanium , Locking Anterolateral Distal Tibial Plate:(L/R):, All Sizes Titanium , Locking Broad Plate: 4.5/5.0Mm:, All Sizes Titanium , Locking Calcaneal Plate: D Type:(L/R):, All Sizes Titanium , Locking Calcaneal Plate: P Type:(L/R):, All Sizes Titanium , Locking Calcaneal Plate:(L/R):, All Sizes Titanium , Locking Cancellous Screw 3.5Mmxf.Th.-, All Sizes Titanium , Locking Cancellous Screw 5.0Mmxf.Th.-, All Sizes Titanium , Locking Clavicle Hook Plate: 3.5Mm:(L/R): All Sizes Titanium , Locking Curved Reconstruction Plate (Roundhole):3.5Mm:, All Sizes Titanium , Locking Curved Reconstruction Plate: 3.5Mm:, All Sizes Titanium , Locking Dhs Barrel Plate All Sizes Titanium , Locking Distal Femu Rplate:(L/R):, All Sizes Titanium , Locking Distal Fibula Plate: 3.5Mm:, All Sizes Titanium , Locking Distal Humerus Plate Dorsolatera With Support: 2.7/3.5Mm:(L/R), All Sizes Titanium , Locking Distal Humerus Plate Dorsolateral:2.7/3.5Mm:(L/R):, All Sizes Titanium , Locking Distal Humerus Plate Medial:2.7/3.5Mm:(L/R):, All Sizes Titanium , Locking Distal Radius (Head4/5Hole)Volarplate:2.7Mm/3.5Mm:(L/R): All Sizes Titanium , Locking Distal Radius Volar Plate:3.5Mm:(L/R):, All Sizes Titanium , Locking Extra-Articular Distal Humerus Plate:3.5Mm:(L/R):, All Sizes Titanium , Locking Lateral Distal Fibula Plate:(L/R):, All Sizes Titanium , Locking Lateral Tibial Plate:(L/R):, All Sizes Titanium , Locking L-Buttress Plate: 4.5/5.0Mm: All Sizes Titanium , Locking Medial Distal Tibial Plate With Tab:(L/R):, All Sizes Titanium , Locking Medial Distal Tibial Plate:(L/R):, All Sizes Titanium , Locking Medial Proximal Tibia Plate 3.5Mm:(L/R): All Sizes Titanium , Locking Medial Proximal Tibial Plate5.0Mm:(L/R): All Sizes Titanium , Locking Narrow Plate: 4.5/5.0Mm:, All Sizes Titanium , Locking Olecranon Plate: 3.5Mm:(L/R): All Sizes Titanium , Locking Pelvic Curved Plate: 3.5Mm: All Sizes Titanium , Locking Pelvic Plate: 3.5Mm: All Sizes Titanium , Locking Philos Plate: 3.5Mm: All Sizes Titanium , Locking Postero Medial Proximal Tibial Plate: All Sizes Titanium , Locking Posterolateral Distal Fibula Plate:(L/R): All Sizes Titanium , Locking Proximal Femur Plate:4.5/5.0Mm:(L/R): All Sizes Titanium , Locking Proximal Humerus Plate:3.5Mm:, All Sizes Titanium , Locking Proximal Tibia Plate 3.5Mm(Ztype):(L/R): All Sizes Titanium , Locking Proximal Tibia Plate 3.5Mm:(L/R): All Sizes Titanium , Locking Proximal Tibia Plate 5.0Mm:(L/R): All Sizes Titanium , Locking S-Clavicle Plate With Lateral Extension: 2.7/3.5Mm:(L/R):, All Sizes Titanium , Locking S-Clavicle Plate: 3.5Mm:(L/R):, All Sizes Titanium , Locking Screw 2.7Mm(S.T.)-, All Sizes Titanium , Locking Screw 3.5Mm(S.T.)-, All Sizes Titanium , Locking Screw 5.0Mm(S.T.)-, All Sizes Titanium , Locking Small Plate: 3.5Mm:, All Sizes Titanium , Locking Small Tplate Obliqueangeled:3.5Mm:(L/R): All Sizes Titanium , Locking Small Tplate Rightangeled:3.5Mm:, All Sizes Titanium , Locking Straight Reconstruction Plate (Roundhole):3.5Mm:, All Sizes Titanium , Locking Straight Reconstruction Plate:3.5Mm:, All Sizes Titanium , Locking T-Buttress Plate: 4.5/5.0Mm: All Sizes Titanium , Locking Tomo Fix Medial High Medial Plate (Osteotomy):3.5Mm:, All Sizes Titanium , Malleolar Screw3.5Mm-, All Sizes Titanium , Malleolar Screw4.5Mm-, All Sizes Titanium , Mechanical Wire Tensioner, All Sizes Titanium , Modular Bipolar Cup [Collar+3,0,-3], [Ball - All Sizes Titanium , Modular Bipolar Stem [Small,Medium,Large], All Sizes Titanium , Multipin Clamp, All Sizes Titanium , Nut, All Sizes Titanium , Nylonnut, All Sizes Titanium , Olive Wire 400Mm, All Sizes Titanium , Open Single Pin Clamp, All Sizes Titanium , Paediatric Dhs Barrel Plate: 3.5Mm:, All Sizes Titanium , Paediatric Dhss Crew With Compression Screw, All Sizes Titanium , Pfn Bolt6.5Mm-, All Sizes Titanium , Pfnbolt8.0Mm-, All Sizes Titanium , Post Male/Female- All Sizes Titanium , Proxima Femur Nail Antirotation (Pfna -Ii):Short:, All Sizes Titanium , Proximal Femur Nail Antirotation (Pfna-Ii):Long:(L/R):, All Sizes Titanium , Rush Nai All Sizes Titanium , S.S. Wire-16,18,20,22,24Gauge, All Sizes Titanium , Scahnz Pin All Sizes Titanium , Schanz Pin Bolt, All Sizes Titanium , Schanz Pin Introducer, All Sizes Titanium , Single Pin Clamp (Deluxe), All Sizes Titanium , Single Pin Clamp (Ordinary), All Sizes Titanium , Sirus Nail Bolt All Sizes Titanium , Small Spanner, All Sizes Titanium , Spacing Washer, All Sizes Titanium , Spiked Ligament Staple [Small&Large], All Sizes Titanium , Spiked Ligament Washer, All Sizes Titanium , Square Nail [Radius/Ulna] All Sizes Titanium , Steinman Pin All Sizes Titanium , Straight Plate All Sizes Titanium , Suture Dis Cwasher, All Sizes Titanium , Suture Discwith -Regular, All Sizes Titanium , Suture Discwith -Conical, All Sizes Titanium , Telescopic Rod All Sizes Titanium , Thompsons Prosthesis Non-Sterile, All Sizes Titanium , Thompsons Prosthesis Sterile, All Sizes Titanium , Threaded Guide Wire- All Sizes Titanium , Threaded K. Wire Double Ended - All Sizes Titanium , Threaded Rod- All Sizes Titanium , Threaded Rod-Slotted- All Sizes Titanium , Threaded Socket- All Sizes Titanium , Tibial Post Fixation Screw All Sizes Titanium , Transverse Clamp, All Sizes Titanium , Triple Trocarset, All Sizes Titanium , Tubeto Tube Clamp, All Sizes Titanium , Tubular Rod(Perinchrate), All Sizes Titanium , Twin Adjustable Clamp-Curved, All Sizes Titanium , Twin Adjustable Clamp-Straight, All Sizes Titanium , Twisted Plate- All Sizes Titanium , Washer (Slotted), All Sizes Titanium , Wire Fixation Bolt-Slotted & Cannulated, All Sizes Titanium , Wrenchoqube All Sizes Titanium , K Wire Sterile Double All Sizes Titanium , 10X14 Medium Tray , Autoclave Drum , Bipolar Cautery , Boiler , Draping Sheet , Duragibre , Ethlon 1-0Rc , Green Draping Sheet , Half Anoscope , Indloop , Isocyanne Acryl Glue , Isoflurane Injection , Laparoscopic Babcock , Laparoscopic Grasper , Laparoscopic Sheath , Lt Clump 300 , Lt Clump 400 , Macroporous Hermial Mush , Monocryl 4-0 Rc , Neostigmine + Glycopyalate (Reversal) Injection , Open Chele Clip Applicator Huom , Ot Gown , Plastic Laparoscopic Port 10 Mm , Plastic Laparoscopic Port 5 Mm , Proctoscope , Prolene 1-0 Rb , Prolene 2-0 Rb , Prolene 3-0 Rb , Pulse Oximeter , Reservoir Bag Below Jar , Skin Marker , Tissue Adhesive Glue , Tracheastong Tray (T.T) , Tridos Vicryl 2-Rb , Vacuronium Injection , 45 Degree Kelmen 0.9Mm Phaco Sleeve (Alcon) , 45 Degree Kelmen 0.9Mm Phaco Tip (Alcon) , Angled Vannas Scissors , Anterior Chamber Iol (Power Range + 1.0 Ds To + 25.0 Ds ) , Artery Forceps (Medium) , B Class Autoclave , Barraquer Needle Holder , Barraquer Wire Speculum , Bimanual I & A Handpiece ( For Phaco 1 Set) , Blades For Eye Surgey Crecent 2.6 , Blades For Eye Surgey Implant 5.2Mm (Keratone) , Blades For Eye Surgey Keratones 2.8Mm Keratone , Blades For Eye Surgey Keratones 3.2Mm Keratone , Bome Plier , Bowmanns Probes , Capsulaorhexis Lit Rate Foeceps With Kirby Round Handle 103Mm Length , Capsulorhexis Forceps 23G With Micro Grasping Tip , Cassette For Laureate Phaco ( Alcon) , Castrovejo Vernier Calliper ( Stainless Steel) , Castroviejo Corneal Scissor , Chalazion Clamp , Chalazion Curette , Conjunctival Scissor , Corneal Universal Curved Scissor , Dastoor Superior Rectus Forceps , Direct Opthalmoscope Bulb With Charger Handle (Heine) , Epilation Forceps , Eye Aspiration Canula 20 No & 22 No. , Eye Bowling , Eye Cannula , Eye Speculum With Adustable Spread (Screw Type) , Eye Vectus , Formalin Chamber , Halogen Bubl 15V.24V (150W) 24V (250W) With Reflection , Hydrophillic Acrylie Foldabale Iols In Preloaded Delivery System Optical Diameter 6Mm , Overall Length 12.5Mm To 13 Mm Optic Design Biconvex 360Degrees Squre Edge And Aspheric Optics Dioptric Range + 1.0 Ds To 30 Ds , Hydroxypropyl Methyleellulose Inj. 2%, 2Ml Pfs (Glass Syring) , Hydroxypropyl Methyleellulose Inj. 2%, 5Ml Pfs (Glass Syring) , Hydrrodissection Cannula , I&A Cannula 18G, 20G, 22G , Instrument Tray , Instrument Tray ( Set Of 15 Instrument) , Iol Dialer , Iris Repositor , Irrigation & Aspiration Cannula 21G (Simco) , Irrigation & Aspiration Cannula 22G (Simco) , Irrigation & Aspiration Cannula 23G (Simco) , Irrigation Wire Vectis 22G , Kidney Tray Large , Kidney Tray Small , Kratz Barraquer Wire Speculum Adult (Size) , Large Bowls , Laureate (Alcon) Phaco Canulla , Laureate (Alcone) Phaco Tips Cleves , Lens Holding Forceps T Type (110Mm) , Lensometer , Lims 1*2 Teeth Extrafine Forceps , Lims Forceps , Mc Pherson Forceps , Mcpherson Angled 12Mm Castroviejo Forceps (109Mm Size) , Medelec Corneal Forceps Staight Micro 1*2 Length , Medium Needle Holder , Mephesson Forceps Angled , Micro Capsulorhexis Forceps , Micro Vanna Scissor , Mosquito Artery , Mosquito Artery Curved , Mosquito Forceps , Mvr Blad 20No. Angled Blade , Needle Holder Barraquer Curved W/O Locl &Lock , Opthalamoscope Bulb , Phaco Chopper , Phaco Spatula Cum Rotator Doublr Ended , Pierse Corneal Forceps (Hoskin) , Pinky Ball (Eye) , Plain Scissor (Small) , Presbiopics Spectacles + 0.50 Ds To + 3.0 Ds , Proparacian Eye Drop , Punctum Dilator , Retinoscope With Charger Handle &Charger , Self Retaining Eye Speculum (Liberman) , Simco Irrigation And Aspiration , Simcoes 18A Cannula 23G,22G , Sinsky Hook , Slik/Nylon 10-0 , Small Bowls , Sponge Holding Forceps , Superior Rectus Forceps 1*2 Teeth , Suture Tying Forceps Curved , Suture Tying Forceps Straight , Tenotomy Scissor , Tonometer , Torch , Trabeudectomy Punch , Travoprost 40 Ug/Ml 2.5Ml Vial Eye Drops 40 Ug/Ml 2.5Ml , Trial Lense Set , Utrata Capsulorhexis Forceps , VannaS Scissor ( Angled) , Vernier Calliper Stainless Steel , Vertical Phaco Chopper , Vicryl Suture 6-0 , Vicryl Suture 8-0 , Vision Box For Eye , Wescott Tenotomy Scissor , Wire Speculum , Wire Vectis (Irrigating) , Wrench For Alcon Phaco Tip (Metal) , Antrum Curette , Antrum Grasping Forceps , Antrum Nasal Scissor Straight , Tonsil Snare , Waugh Dissecting Forceps Plain , Adenoid Curette With Cage Small & Large , Adenoid Curette Without Cage Small & Large , Adson Forceps Plain , Adson Forceps Tooth , All Ent Opd Instrument , Antrume Ball Double Ended , Antrume Punch Backward Cutting Up , Antrume Punch Through Cutting , Antrume Sickle Knife , Antrume Suction Cannula , Ash Septum Forceps , Aur Frichet Nasal Retractor , Backhouse Towel Forceps , Ballenger Swivel Knife , Beals Respatary , Birkett Tonsil Artery Forceps Straight & Curved , Blakeley Nasal Forceps 90 Degree Upward , Blakesley Nasal Forceps 45 Degree Upward , Blakesley Nasal Forceps Straight , Bone Cutting Forceps. , Boyle Davis Mouth Gag Set Of 5 Blades Adult & Child. , Chiset , Circular Knife , Cottle Alar Retractor , Curved Suction 1,2,3,4 1Set , Denis Brown Tonsil Holding Forceps , Draffine Bipod Stand With Plates. , Drill Burr - Cutting- 5,4,3,2 Diamond- 5,4,3,2 , Drill Machionl (Marathan) , Ear Speculum Set Of 4 Black Finish , Endoscope 0 , 45, 70 Degree With Complete Unit. , Ent Examination Unit , Ent Otoscope , Farabeuf Elevator , Freer Elevator Double Ended , Frogior Suction Cannula , Gauge , Hand Piece Nsk Straight , Hartman Aurat Forceps , Hause Diper Nipper , Headlight 10W , Heyman Turbinectomy Scissors , House Curret Double Ended , Iris Scissors 6 , Irrigation And Aspiration Cannula , Joseph Nasal Rasp Fine & Coarse , Joseph Nasal Scissor , Karrisian Punch , Killian Nasal Speculum Small, Medium, Large , Kilner Retractor , Lucs Nasal Forceps Small, Large , Mallet , Massing Elevator Double Ended , Mastoid Retractor 2X2 Pronges , Mastoid Retractor 3X3 Pronges , Mastoid Suction Tube Set Of 4 , Mastoid Suction Tube Set Of 4 , Micro Crocodile Cup Forceps Set , Micro Crocodile Forceps Serrated Set -2 , Micro Ear Suction Tips Set Adapter , Microscopezeiss F Recording , Needle 45 Hook , Needle 90 Hook , Needle Curved , Needle Straight , Negus Pusher Forceps , Negus Tonsil Artery Forceps Long Curved & V- Shaped , Oesteotome , Peritonsillar Sillar Forceps , Plaster Knife , Pta (Pure Tone Audiometers) With Oae , Sickle Knife , Sterilizing Box + Double Silicon Matt , Sterilizing Box With Double Silicon Matt , Suction Elevator With Stillet , Suction Elevator With Stillet. , Suction Machine Portable And For Ot ( 1 Horse Power) , Super Punch Through Letting Up Turned , Superior Punch Through Cutting St. , Thudicum Nasal Speculum Set Of 3 , Tilley Nasal Packing Forcep , Tonsil Dissector , Tonsil Needle Holder , Tonsil Piller Retractor And Dissector , Tonsil Scissor Straight & Curved , Tonsillar Knife , Walsham Septum Forceps , Walter Scissors , Waugh Dissecting Forceps 1X2 Teeth , Yunkour Suction Tube , Black Hit , Candle Round( Big Size) , Detergent Liquid 1 Litre ( (Isi/Iso/Ce Certified)) , Detergent Powder 1Kg ( (Isi/Iso/Ce Certified)) , Disposable Trimmer Plus Skin Prep Razor ( (Isi/Iso/Ce Certified)) , Floor Duster 1X1mt Superior Quality , Hand Duster 22 X 22Cm Superior Quality , Harpic Bathroom Cleaner 500 Ml (Red) ( (Isi/Iso/Ce Certified)) , Harpic Toilet Cleaner 500 Ml (Blue) ( (Isi/Iso/Ce Certified)) , Heat Cure Acrylic Powder (Isi/Iso/Ce Certified) Pink , Hydrogen Peroxide 3%, 100 Ml ( (Isi/Iso/Ce Certified)) , Hydrogen Peroxide Solution 6%, 400 Ml , Lead & Colour Pencil For Tissue Labeling ( (Isi/Iso/Ce Certified)) , Liquid Hand Wash Soap 5 Litre ( (Isi/Iso/Ce Certified)) , Liquid Hand Wash Soap 5 Litre (Safe For Skin)Isi/Iso/Gmp Certified , Loader (Iron Trolley Stainless Steel With Wide& Large Wheels) Weight Bearing Capacity 300 Kg. (For Goods Transporation Inside Hospital) , Mattress Hospital With Rexin Cover 72*36*4 Inch 40 Density 3 Year Warranty ( (Isi/Iso/Ce Certified)) , Micro Crocodile Forcep Curved ( (Isi/Iso/Ce Certified)) , Mopping Trolley With 2 Bucket On Four Wheels ( (Isi/Iso/Ce Certified)) , Mosquito Repellent Liquid Complete Set (Machine With Reffil) Unit Rate ( (Isi/Iso/Ce Certified)) , Mosquito Repellent Liquid ( Reffil Only) Unit Rate , Naphthalene Balls (Repellent Against Insects & Moths) Pack Of 200 Gm. ( (Isi/Iso/Ce Certified)) , Naphthalene Balls (Repellent Against Insects & Moths) Pack Of 200 Gm. ( (Isi/Iso/Ce Certified)) , Needle Destroyer 1.5 Litre Stainless Steel ( (Isi/Iso/Ce Certified)) , Phool Jharu (Baans) Standard Quality Per Kg. , Phool Jharu Standard Quality Per Kg. , Thermocol Box Size 18.5X12.5X13 Cm. , Toilet Cleaner Brush Superior Quality , Tongue Depressor Ss ( (Isi/Iso/Ce Certified)) , Tongue Depressor Ss ,L-Shape ( (Isi/Iso/Ce Certified)) , Wiper For Cleaning Floor(Long Stainless Steel Handle) Good Quality , Wiper For Cleaning Floor(Long Stainless Steel Handle) Good Quality (Scotch Brite) , Squeeze Bottle 100Ml , Falcon Tube 50Ml , Falcon Tube Stand , Ortho-Tolidine Solution/Reagent 500Ml , Ortho-Tolidine Test Kit (5 Ppm Level) , Dengue Elisa Igm Kit , Elisa Reader Paper Roll , Bmw Poly Bags (Red, Black, Yellow, Blue) Per Kag , Bio Waste Dustbin 15-20 Litter
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 12
2.
Power #11327603 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 1 Overhauling Of Horizontal Pumps (With Replacement Of De And Nde Bearings) Of Drive Rating Above 150Kw 415V And 6Point6Kv Capacity; As Per Tender .. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 2 Overhauling Of Horizontal Pumps (With Replacement Of De/Nde Bearing) Of Drive Rating Above 150Kw 415V And 6Point6Kv Capacity; As Per Tender Condit.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 3 Overhauling Of Horizontal Pumps (Without Replacement Of Bearings) Of Drive Rating Above 150Kw 415V And 6Point6Kv Capacity; As Per Tender Condition.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 4 Overhauling Of Horizontal/Vertical Pumps (With Replacement Of De/Both Bearings) Of Drive Rating From 50Kw To 150Kw, 415V Capacity; As Per Tender C.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 5 Overhauling Of Horizontal/Vertical Pumps (With Replacement Of De/Nde Bearings) Of Drive Rating From 50Kw To 150Kw, 415V Capacity; As Per Tender Co.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 6 Overhauling Of Horizontal/Vertical Pumps (Without Replacement Of Bearings) Of Drive Rating From 50Kw To 150Kw, 415V Capacity; As Per Tender Condit.. , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 7 Overhauling Of Horizontal/Vertical Pumps (With Replacement Of De/Both Bearing) Of Drive Rating Upto 50Kw, 415V Capacity; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 8 Overhauling Of Horizontal/Vertical Pumps (With Replacement Of De/Nde Bearing) Of Drive Rating Upto 50Kw, 415V Capacity; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 9 Overhauling Of Horizontal/Vertical Pumps (Without Replacement Of Bearings) Of Drive Rating Upto 50Kw, 415V Capacity; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 10 Preventive Maintenance Activities On Horizontal/Vertical Pumps Of Drive Rating Above 150Kw 415V And 6Point6Kv Capacity; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 11 Preventive Maintenance Activities On Horizontal/Vertical Pumps Of Drive Rating From 50Kw To 150Kw, 415V Capacity; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 12 Preventive Maintenance Activities On Horizontal/Vertical Pumps Of Drive Rating Upto 50Kw, 415V Capacity; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 13 Overhauling Of Twin Lobe Positive Displacement Blowers In Raw Water Pump House Of Drive Rating Upto 5Kw, 415V Capacity; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 14 Replacement Of Cooling Tower Bush In Cooling Tower Fans; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 15 Preventive Maintenance Of Cooling Tower Fans; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 16 Overhauling Of Cooling Tower Fan Gear Box; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 17 Preventive Maintenance Of Diesel Engines Of Power Rating 156Hp Capacity; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 18 Cleaning And Servicing Of Automatic Self Cleaning Filter In Service Wph; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 19 Replacement Of Bearing On Nde Of Pumps Of Drive Rating Above 150Kw 415V And 6Point6Kv Capacity; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 20 Replacement Of Bearing On Nde Of Pumps Of Drive Rating From 50Kw To 150Kw, 415V Capacity; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 21 Replacement Of Bearing On Nde Of Pumps Of Drive Rating Upto 50Kw, 415V Capacity; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 22 Replacement Of Bearing On De And Nde Of Motor Of Drive Rating Upto 50Kw, 415V Capacity; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 23 Replacement Of Bearing On De Of Motor Of Drive Rating 400Kw To 590Kw; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 24 Replacement Of Bearing On Nde Of 6Point6Kv Motor Of Drive Rating 400Kw To 590Kw; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 25 Overhauling Of Auxiliary Sea Water Pump; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 26 Opening, Cleaning And Normalization Of 250Nb Tee Type Strainers; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 27 Opening, Cleaning And Normalization Of 450Nb Tee Type Strainers; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 28 Opening, Cleaning And Normalization Of 650Nb Tee Type Strainers; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 29 Gasket (Pair) Replacement In Between Valve Flanges Of Size From 500Nb To 1000Nb Lines Inline With Scope Of Work; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 30 Gasket Replacement In Between Valve Flanges Of Size From 250Nb To 450Nb Lines; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 31 Gasket (Pair) Replacement In Between Valve Flanges Of Size Upto 250Nb Lines Inline With Scope Of Work; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 32 Cleaning, Servicing And Normalization Of 500Nb Size Self Cleaning Filter As Per The Scope Of Work; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 33 Cleaning, Servicing And Normalization Of Nrv Of Size Of 150Nb To 200Nb; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 34 Cleaning, Servicing And Normalization Of 550Nb Size Nrv As Per The Scope Of Work; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 35 Performing Preventive Maintenance On Air Handling Unit (Ahu) As Per Scope Of Work; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 36 Performing Preventive Maintenance On Small Size Blowers Having Casing Dia Below 1 Meter As Per Scope Of Work; As Per Tender Conditions , Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Sl No 37 Performing Preventive Maintenance On Large Size Blowers Having Casing Dia 1 Meter And Above As Per Scope Of Work; As Per Tender Conditions
Contract Date: Ref. Documents Contract Value : 23.92 Lakh
Boards / Undertakings / PSU No of Bidders 5
3.
Civil Aviation #11310400 AOC
Bids Are invited for Annual Operation and Maintenance of HT/ LT electrical & mechanical installations of 33/0.433 KV Substation, Operation of Lifts and Escalators, DG sets, New Terminal Building, Car Parking Area, Old power house, 300kWp solar power plant, Cargo building, Admin offices, etc. including repair, maintenance, attending to complaints/fault/breakdowns and taking rectification action, ensuring serviceability/ satisfactory working condition of the system, carrying-out Preventive maintenance, upkeeping of records/documentation etc. as specified on all days i/c Sundays and Holidays as per Agreement conditions/ terms & conditions of tender documents by providing/engaging manpower as mentioned in the SCC clause-12 with sufficient number of relievers are to be deployed throught out the contract period.(NOTE: Shift timing will be decided by Engineering-in-charge or his representative as per the site requirement and flight operational hours.) , Annual Operation of HVAC system (Consisting of Centrifugal type water cooled Chiller 02 nos. with VFD giving actual Capacity of 700TR , Cooling tower 02 no. each 700 TR, Centrifugal Pumps, AHUs 19 nos. of different capacity, Hot Water pumps-02 no. each 160 KW, BMS, Ozone system, Exhaust system, water softening plant, Complete VRF system and Air curtains etc as specified on all days i/c Sundays and Holidays as per Agreement conditions/ terms & conditions of tender documents by providing/engaging manpower as mentioned in the SCC clause-12 with sufficient number of relievers are to be deployed throught out the contract period.(NOTE: Shift timing will be decided by Engineering-in-charge or his representative as per the site requirement and flight operational hours.)
Contract Date: Ref. Documents Contract Value : 2.57 Crore
Boards / Undertakings / PSU No of Bidders 13
Uttarakhand View Result →
4.
Health and Family Welfare #11302941 AOC
Bids Are Invited For Supply And Installation Of Equipments For Replacement And Standby For Stp Operation At Instem C Us-Supply, Fixing, Testing And Commissioning Of Magnetic Flow Meter Suitable For Sewage Water Line, 150 Mm Dia Size Pipeline, Suitable For Dn150 Pipeline With Flange-Type Connection. Model Code: Magflow 6415, With Remote Transmitter. The Measuring Sensor Shall Be Flangemounted As Per Ansi 150, With Flange Material Of Carbon Steel. The Sensor Lining Shall Be Ptfe Electrodes Made Of Ss316L, And Measuring Tube Of Ss304, With Coil Housing Of Carbon Steel. The Flow Meter Shall Have Protection Class Ip68, Cable Length Of 10 Meters, And Accuracy Of +0.5%. The Supply Shall Include Mating Flanges, Gaskets, And Fasteners (Galvanized), 1 Set (2 Nos Per Flow Meter), Ensuring Complete Installation, Testing, And Commissioning For Reliable And Precise Flow Measurement. Supply, Fixing, Testing And Commissioning Of Magnetic Flow Meter Suitable For Sewage Water Line, 100 Mm Dia Size Pipe Line, Suitable For Dn150 Pipeline With Flange-Type Connection. Model Code: Magflow 6415, With Integral Transmitter. The Measuring Sensor Shall Be Flangemounted As Per Ansi 150, With Flange Material Of Carbon Steel. The Sensor Lining Shall Be Ptfe, Electrodes Made Of Ss316L, And Measuring Tube Of Ss304, With Coil Housing Of Carbon Steel. The Flow Meter Shall Have Protection Class Ip67, And An Accuracy Of ±0.5%. The Supply Shall Include Mating Flanges, Gaskets, And Fasteners (Galvanized), 1 Set (2 Nos Per Flow Meter), Ensuring Complete Installation, Testing, And Commissioning For Precise And Reliable Flow Measurement In Water Or Industrial Pipelines. Supply, Fixing, Testing And Commissioning Of Everest Make Twin Lobe Air Blower With 5 Hp Motor, Model M-450, Suitable For Continuous Air Handling Services For Sewage Treatment Plant And Indoor Installation. The Blower Shall Have A Capacity Of 100 M³/Hr, With Inlet Conditions At Atmospheric Pressure And Discharge Pressure Of 0.55 Kg/Cm³. Operating Speed Shall Be 1598 Rpm With Brake Horsepower At Duty Point Of 3.84 Bhp, Driven By A Recommended 5 Hp, 1450 Rpm Motor. The Blower Shall Have A 40 Mm Opening, Horizontal Flow Orientation, Lip Seal For Sealing, And Lubrication By Grease-Packed Pulley & Bearings And Oil-Splash For Gears And Gear-End Bearings. Drive Shall Be Via V-Belt With Clockwise Rotation As Viewed From Pulley End. Material Of Construction Shall Include: Main Casing And Side Plate Ci Gr. Fg260 (Is:210), Rotor Sg Iron, Shaft-En 19, Gears-20Mncr5/B970-3/Ais15120, Anti-Friction Bearings, And Ms Fabricated Base Frame. The Blower Shall Be Supplied Complete, Ready For Installation, Operation, And Maintenance, Conforming To Relevant Standards For Materials, Performance, And Reliability. Total Quantity : 1
Contract Date: Ref. Documents Contract Value : 7.30 Lakh
Government Departments No of Bidders 2
5.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
6.
Civil Aviation #11209499 AOC
Bids Are invited for Operation and maintenance of Electrical and Mechanical installations - Operation and maintenance of Electrical and Mechanical installations of operational and non operational areas including Terminal buildling, ATS Building, Fire station, Electrical Substation and other ancillary buildings for round the clock operation on all days including Sundays and Holidays by engaging following manpower along with providing required tool and consumables as specified in special conditions of contract for day to day maintenance except spares. The job includes preventive, routine maintenance, attending complaint or fault or breakdown by taking rectification actionensuring serviceability and satisfactory working condition of the system, maintaining all records and documentation etc. complete as per agreement conditions and as per the instruction of EIC.1. Supervisor (Highly Skilled) - 01 no.2. Document Assistant (Highly Skilled) - 01 no.3. Wireman (Skilled) - 07 nos.4. Semi-skilled- 06 nos.5. Helper (Unskilled) - 03 nos.(The above manpower is excluding reliever) , Job contract for Operation and Day to Day Maintenance Services of Airport Systems equipments - Job contract for Operation and Day to Day Maintenance Services of Airport Systems equipments including SCCTV Camera System, FIDS , PA System, HHMD, DFMD, Security Equipments, BDDS equipments, XBIS machines, ETD Equipment etc. installed at terminal building, ancillary building at Rupsi Airport. Job also includes attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, providing registers and log books as per formats given in tender document and maintenance of daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, registers and log books and coordination with OEM Technicians during CMC works etc. by deploying following manpowers as per scope of work given in special conditions of contract shall be ensured round the clock (ie. in one shifts basis) on all days including Sundays & National Holidays as per direction of EIC and as per attached Annexure-A of ATC. 1. Supervisor (High skilled) -01 no. 2. Technician ( Skilled) -01 no. (The above manpower is excluding reliever) , Execution of item of Schedule of rates CPWD DSR 2022 as and when required - Execution of item of Schedule of rates CPWD DSR 2022 as and when required for attending breakdown, repair and maintenance and upkeep of internal & external electrical installations as per direction of E-I-C at different locations of operational and non operational area i/c Terminal Building, ATS Building, Fire Station, Electrical substation and other ancillary buildings etc. The bidder shall quote the rate in INR only including price escalation for 01 year for the job corresponding to an amount of Rs. 1,00,000.00 (including GST from DSR 2022 items) and percentage (%) above/below shall be calculated by AAI and paid accordingly. , Testing of Transformer oil sample including conducting BDV test and submission of test report etc complete as required - Testing of Transformer oil sample including conducting BDV test and submission of test report etc.complete as required , Filtration of Transformer oil of 630 kVA transformer - Filtration of Transformer oil of 630 kVA transformer to attain acceptable di-electric strength by hot streamline process including arrangement of plant/machine, transportation etc. complete as required by topping of Transformer oil and BDV testing including submission of test reports before & after dehydration of oil. (excluding cost of Transformer oil) (Item is to be executed if the BDV value of transformer oil is found below the stipulated value). , Servicing and Checking of LT Air Circuit Breaker - Servicing & Checking of LT Air Circuit Breaker (ACB) of L&T U POWER OMEGA make by deploying Authorised Service Personnel of Manufacturer/ OEMs Service Dealers as per OEMs standards complete as required and submission of service reports. , Servicing and Checking of HT Vacuum Circuit Breaker - Servicing & Checking of HT Vacuum Circuit Breaker (VCB) of Siemens make by deploying Authorised Service Personnel of Manufacturer/OEMs Service Dealers as per OEMs standards complete as required and submission of service reports. , Calibration and testing of relays at HT Panel - Calibration and testing of following relays at HT Panel by deploying Authorised Service Personnel of Manufacturer/OEMs Service Dealers as per OEMs standards complete as required and submission of service reports.i) Vamp 57 - 5 Nos. (Numerical type of Schneider Make)ii) VAJH13 - 5 Nos. (Tripping Relay of Alstom Make)iii) VAX31 - 5 Nos. (Trip Circuit Supervision Relay of Alstom Make)iv) VAA33 - 4 Nos. (Auxiliary Relay of Alstom Make) , Calibration and testing of following relays at LT and Synchronizing Panel - Calibration and testing of following relays at LT & Synchronizing Panel by deploying Authorised Service Personnel of Manufacturer/OEMs Service Dealers as per OEMs standards complete as required and submission of service reports.i) VAJH13 - 2 Nos. (Tripping Relay of Alstom Make)ii) VAX31 - 2 Nos. (Trip Circuit Supervision Relay of Alstom Make)iii) CCUM21PF112A - 2 Nos. (Definite Time Reverse Power Relay of Areva Make)iv) CAG14AF15A - 2 Nos. (Instantaneous Earth fault Relayof Alstom Make) , Scrubbing, cleaning the existing surface of cubicle panel, feeder pillars and painting - Scrubbing, cleaning the existing surface of cubicle panel, feeder pillars & painting the same with one coat of primer and one coat of synthetic enamel paint of approved colour etc. complete as required , Lettering of maximum 2 inch size Alphabetic or numerical - Lettering of maximum 2inc size (Alphabetic / numerical) on the finished painted surface of feeder pillar / panel / earth pits with synthetic enamel paint of approved colour etc. complete as required. , Cleaning the surface of MS chequered plates - Cleaning the surface of MS chequered plates and painting with one coat of primer and two coats of synthetic enamel black paint etc. complete as required. , Supply and replacement of silica gel in breather of existing 630 KVA transformer etc. complete as required , Lifting and lowering of 10 HP borewell submersible motor pump set - Lifting and lowering of 10 HP borewell submersible motor pump set along with dismantling of complete delivery pipeline, removal of pump sets, disconnection of flexible submersible cable, reassembling of submersible pump, complete delivery pipeline, fixing / laying of existing submersible cable including electrical connection, testing and commissioning etc. complete as required. , Servicing and complete overhauling of 10 HP borewell submersible motor pump set - Servicing and complete overhauling of 10 HP borewell submersible motor pump set including replacement of defective bearing, coupling, impellar, mechanical & oil seal, heat varnishing of motor etc. complete as required , Decoration of Terminal Building and Canopy of Rupsi Airport - Decoration of Terminal Building and Canopy of Rupsi Airport, in Tri-Colour, with the following lighting items of pattern approved by E-i-C or his authorized representative, for 03 days etc. complete as required.i) 60 nos. LED series lighting chain (minimum chain length 5m and uniform spacing between chains not more than 0.75 m)ii) 20 nos. RGB LED Facade/ Disco/ Flood light fittings (minimum 10000 lumen output) , Supply and replacement of defective smoke detectors - Supply and replacement of defective smoke detectors of suitable make & model compatible to theexisting system. , Supply and replacement of defective manual call point - Supply and replacement of defective manual call point of suitable make & model compatible to the existing system , Supply of convertor or driver suitable for PHILIPS make 20 W downlight types LED luminaires or fittings - i) PHILIPS make 20 W downlight Type DN195B LED20S , Supply of convertor or driver suitable for OSRAM make 120W types LED luminaires or fittings - ii) OSRAM make 120W Type. LEDENVO LED Street Light , Supply of convertor or driver suitable for HAVELLS make 18 or 20 W downlight types LED luminaires or fittings - iii) HAVELLS make 18/20 W downlight , Supply of convertor or driver suitable for WIPRO make 36W 2ftx2ft recess mounted fitting - iv) WIPRO make 36W 2ftx2ft recess mounted fitting , Supply of 1000W 240V Lamp suitable for Aerodrome Beacon - Supply of 1000W , 240V Lamp suitable for Aerodrome Beacon of model AB-1000F Make- Manairco Inc as and when required. , Supply of Aerodrome Beacon - Supply of Aerodrome Beacon of model AB-1000F Make- Manairco Inc as and when required. , Calibration of Clinometer - Calibration of Clinometer from Govt. Test laboratory/ OEM, submission of test report etc., complete as required i/c taking the equipment from AAIs site to laboratory and bringing back the same from laboratory to AAIs site. , Supply of reflector suitable for AMA make PAPI - Supply of reflector suitable for AMA make PAPI fittings as and when required. , Supply of 2C x 4 sq mm. Secondary lead with Plug - Supply of 2C x 4 sq mm. Secondary lead with Plug at one end of standard length of 5 m as and when required , Supply of B connector or four way porcelain terminal - Supply of B - connector / four-way porcelain terminal for AMA make PAPI units as and when required , Supply of 5 kV grade 50 Hz AC Isolating Transformer - Supply of following rating 5 kV grade, 50 Hz AC Isolating Transformer, series type, encapsuled inpolyster resin, finally moulded in neoprene type rubber with primary and secondary leads, confirming to latest specifications as required suitable for airfield lighting applications etc. as and when required. 200 Watt, 6.6/6.6 Amp. , Supply of two pin halogen lamp Holder suitable for 200 Watt - Supply of two pin halogen lamp Holder suitable for 200 Watt, 6.6 Amp Lamp as and when required. , Supply of 5 W Screw Cap LED lamp - Supply of 5 W Screw Cap LED lamp suitable for Landing T , efficacy not less than 100 lm/W as and when required. , Supply of Wind Sock Cloth - Supply of Wind Sock Cloth, 13 ft 9 inch length, colour preferably Orange & White and conforming to ICAO Annex-14 as and when required. , Supply and replacement of LED flood light - Supply and replacement of LED flood light for mounting on Wind Direction Indicator, equivalent to Philips make Model BVP132LED16/CW 20W 100-240V WB IN as and when required. , Supply and replacement of Obstruction Light of Wind Direction Indicator - Supply and replacement of Obstruction Light of Wind Direction Indicator as and when required. , Supply and replacement of 180 AH 12 V Lead Acid battery - Supply and replacement of 180 AH 12 V Lead-Acid battery, conforming to IS 14257 1995 with up to date amendments, suitable for high cranking performance of 400 kVA DG set as and when required. , Supply and replacement of 100 AH 12 V Lead Acid battery - Supply and replacement of 100 AH 12 V Lead-Acid battery, conforming to IS 14257 1995 with up to date amendments, suitable for high cranking performance of 62.5 kVA DG set as and when required , Supply of Automaic Electric Hand drier - Supply of Automaic Electric Hand drier of following specifications or equivalentMake OMCO, Model IPX1,Voltage-220-240V, Power 1800W , Servicing, Checking Repairing Overhauling and Testing of CROMPTON make 630 KVA Transformer - Servicing, Checking, Repairing, Overhauling and Testing of CROMPTON make 630 KVA, 11/0.433 KV Transformer including carrying out the following tests by deploying Authorised Service Personnel of Manufacturer/OEMs Service Dealers as per OEMs standards complete as required and submission of reports.a) General inspectionb) IR value test primary to secondary, primary to earth, secondary to earthc) Votage ratio check at all tap position,d) Buchholz relay operatione) OTI operationf) WTI operationg) On-Load Tap changer operation checkh) Cleaning of transformer and replacement of silica geli) Acidity Check test of Transformer Oil. Total Quantity : 599
Contract Date: Ref. Documents Contract Value : 92.89 Lakh
Boards / Undertakings / PSU No of Bidders 7
West Bengal View Result →
7.
Defence #11192596 AOC
Tender For Provn Of Central Mi Room At Nimu; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 43 2 Lump sum price worked out by the contractor for (SITE CLEARANCE, EXCAVATION & EARTH WORK)as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 44 3 Lump sum price worked out by the contractor for (INTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 50 4 Lump sum price worked out by the contractor for (INTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 52 5 Lump sum price worked out by the contractor for (ROAD, PATH & HARDSTANDING)as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 54 6 Lump sum price worked out by the contractor for (SEWAGE DISPOSAL)as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 55 7 Lump sum price worked out by the contractor for (AREA DRAINAGE)as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 56 8 Lump sum price worked out by the contractor for (SHED FOR DG SET)as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 58 9 Lump sum price worked out by the contractor for (HOT WATER SUPPLY)as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 59 10 Lump sum price worked out by the contractor for (EXTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 65 11 Lump sum price worked out by the contractor for (EXTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 66 12 SCH A PART - XII (MISC B/R & E/M ITEMS) (REFER BOQ)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 INTERNAL ELECTRIFICATIONS&F Double door three phase prewired distribution board vertical DB VTPN 8 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA.(Note:- Single Phase MCBs are to be measured and paid for seperately) 14 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 S&F new wall mounted fan of approved make and type complete all as specified and as directed. 16 S&F TV Co-axial socket 1 module, complete all as specified and as directed. 17 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps 18 INTERNAL WATER SUPPLYS&F single piece Vitreous china wash down water closet pan Pedestal Pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs complete all as spd & directed complete all as specified and directed by Engr-in charge.. 19 S&F CP Grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by Engr-in charge. 20 S&F hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hookcomplete all as specified Make: Cera, Jaquar , Marc & Hindware as per Sample and directed by Engr -in Charge 21 S&F Soap dish (S/S), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by Engr-in charge. 22 ROAD, PATH & HARD STANDINGM&L for wet mix macadam (WMM) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of MoRTH (Ministry of Road Transport & Highways) specification of Road and Bridge works 2013. Manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and conslidating required gradient and camber. The finished surface tolerance to be as per table 900-1 of MoRTH specification for road and bridge works 2013 complete all as specified and directed by Engr-in-Charge. 23 M&L for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to BS 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M Dia and 3 M Depth. 26 EXTERNAL ELECTRIC SUPPLYS&F Polycarbonate junction boxes IP 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 Nos MCB SP 2.5 Amp & 4 way industrial connector including clamp made out of MS flat 30x5mm connection from junction box to street light fitting with three single core PVC insulated, PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia complete all as specified and directed by Engr-in-charge. 27 Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. 28 S&FHT/LT MS cable route indicator 4 dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engr-in-charge. 29 Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheetduly powder coated and shall be CPRI Approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, AI bus bar duly covered with heat shrink sleeves colour coaded duly fixed onDMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm sizeMS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of AGE (I) Nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz - 01 No (I/C)(b) MCCB 200 Amps, FP, 25 KA, 415 volts, 50Hz - 02 No ( CHS)(c) MCCB 125 Amps, FP, 16 KA, 415 volts, 50Hz - 04 Nos (APFC, TPN DB -02, Spare )(d) MCB SPN 40 Amps, 10 KA, 220 volts, 50Hz - 03 Nos (Garage,Street light, Spare-1)(e) On load Chengeover 400 Amps 4 pole -01 No (f)Digital voltmeter, with VSS - 01set(g) Digital Ammeter, with CTs & ASS - 01 set(h) LED phase indication lamps RYB - 01 set(j)Single phase Rotary Automatic Light controller Nature switch with voltage range 120-440V,AC,20 Amps,IP-65,50HZ-01 Nos(k) Copper bus bar TPN 600 Amps rating - 01 set 31 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 32 EXTERNAL WATER SUPPLYM&Lfor cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.Note : Suitable size of Tee branch is deemed to be included in the quoted rate. 33 Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingPCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint andall other relevant work complete . 34 M&L for providing tracer/anti freezing cable of capacity 20W/m required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (CENTRAL HEATING SYSTEM)Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 50 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 Notes:- (i) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(ii) The prices should include lifting, shifting and positioning of units at Site.(iii) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer.(iv) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity conforming to relevant IS Code(v) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 37 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below:The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 38 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) Pressure gauges 150 mm dia -03 Nos (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation).Pump capacity are as under:Capacityand pump headnot less than flow 25 USGPM , Head 20 mtr (Refernce Model No. : Armstrong : Series 4300 - 40-150 - 2p - 1.5 kW) each including the Triple duty valve and End Suction guide. 39 EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 . The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). Electrical by pass starter for pump setas recommended by OEM. 40 Expansion Tank of 500 Lts capacity 41 PRESSURIZATION UNIT: for Pump Set -03 Nos with Control Panel and accessories. 42 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 43 Supply, Installation, Testing and Commissioning ofSteel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve andwith threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius. Referemcwe Model Series. 44 1.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 45 2.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 46 3.5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 600 mm of Radiator. 47 5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 900 mm of Radiator. 48 5 kW,Type: 33- DKEK, Length is 2000 mm and Height is 600 mm of Radiator 49 M & L for Pre-insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 50 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 51 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 52 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 53 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 54 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 55 Buried under ground/Exposed to Ambient:80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 56 Cabel Tray :-Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders as per IS code including bolts & nuts, painting suspenders etc. as required of size 150 mm width X 50 mm depth X 1.6 mm thickness 57 Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 58 80 mm dia Butterfly Valve 59 65 mm dia Butterfly Valve 60 50 mm dia Butterfly Valve 61 Supplying, fixing, testing and commissioning of Y-STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified of size 50 mm dia Y strainer. 62 Supplying, fixing, testing and commissioning of NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified of size 50 mm dia NRV. 63 Supplying, fixing, testing and commissioning of Automatic Air Purge Valves forhot water circulation headeras specified of size Automtic Air Purge Valve 20 mm dia. 64 Supplying, fixing, testing and commissioning of Air Separator compleate allas specified of size 50 mm dia. 65 Supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 66 Supplying, fixing, testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 67 Electrical distribution Panel Supply, installation, commissioning and testing of factory made, CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- 68 INCOMERS(i) Bus Bar TPN Al extensible type main bus bars of minimum of 600 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(ii)MCCB 400 Amps, 415 Volt, 36 KA, 4 Pole,Microprocessor release- 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/SimensOUTGOINGS(i) 3Nos- 125A ,25 KA TPNMCCB/ACBwith Microprocessor release (3# Hot Water Generator)(ii) MCB 10 Amp,TPN,10KA, C curve - 06, 3 Nos for Pumps , 2 Nos for Pumps ,01 Nos for glycol transfer pump(iii) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (iv) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(v) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing for approval of panel to GE before execution. 69 LT CABLES : Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed AI conductor armoured cable/unarmoured as required of 1.1 KV grade complete as require (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)Note for 49.01 to 49.04 :- Cable shal withstand temperature variation (-) 35 °C to (+) 35 °C at appx 3500 mtr above sea level. 70 3.5 Core x 70 sq.mm. (Electric Hot Water Generator) 71 4.0 Core x 10 sq.mm. (Pump) and (Pressurization Unit) 72 2 Core x 10 sq.mm. (Pump) 73 2 Core x 6 sq.mm (Pressurization Unit) 74 Earthing complete with Copperearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including Copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge 75 S&F rubber matting conforming to IS-15652-2006 complete as required. of size2m x 1m x 25 mm 76 Glycol - Water SolutionSupplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. (Glycol 45 % ,Water 55 %) 77 For CHS 78 Supply of Gycol for running of Plant for 12 months 79 GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump. 80 OXYGEN GAS MANIFOLD : Supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, NRV and ESSAB make 10x14 regulator complete all as specified and directed by Engr in charge . 81 Supply, installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by Engr in charge . 82 Supply , installation , testing and commission automatic control panel with Analog Display 02 for oxygen complete all as specified and directed by Engr in charge. 83 S&F of copper tubing of size 15 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 84 S&F of copper tubing of size 12 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 85 S&F BS type gas outle with probe for oxygen for medical compleate all as specified and directed by Engr in charge 86 S&F 1/2 Brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by Engr in charge. 87 S&F BPC flow meter (0-15 LPM) including humidfire bottle complete all as specified and directed by Engr in charge . 88 S&F 3/8 Brass ball valveincluding all fittings for complete all as specified and directed by Engr in charge. 89 STAND BY DG SET : Supply,install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wireengine as per IS08528 conforming to CPCB Norms IV, and alternator as per IS08528 of capacity 400 KVA at NTP with control panel having meters, sound proof canopy etc with foundation (As per OEM design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- AC Generator should be suitable for ambient conditions at nimu Leh area. 90 (A) Alternator : Standard design alternator rated at 400 KVA (320KW)net output at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B)DIESEL ENGINE : Vertical diesel engine of suitable capacity, closed circuit as per BS-649 or IS-1002 direct injection type, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running with 10% over loading for 01 hour in every 12 hours as perBS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following Specifications.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) Cooling system (i) Radiator with fan & belts & guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . 91 (c) GOVERNER : Electronic Governer (d) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC(12 volt, 150 AH battery 2 Nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2X12 volt 150 AH capacity. (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES:AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) EXHAUST SYSTEM : should have equipped with emission control device as per latest Govt norms. Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (C)ACOUSTIC ENCLOSURE : All as per CPCB norms IV and OEM of DG Sets design.(D)AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body,dust and vermin proofmade up of CRCA sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers andmounted on floor with PCC pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) Microprocessor based Panel -01 No(ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply.(v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.(vii)Set of indicaters : - (a)Low lube oil pressure (b) DG Set over load(viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF.(x) Set of Instrument fuse (xi)Set of aluminium bus bar of 600 Amps capacity 3 ph, 4 Wire system (xii) Automatic battery charging unit with DC voltmeter, Ammeter and selector switch for trickle/ Boost charging.(xiii) By Pass arrangement of main supply when AMF circuit fail due to any fault with provision of suitable rating change overs and switches. 93 The following items are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department. (ii)The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(iv) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) All civil works including foundation for DGSet as per manufacturers drawing/ specification, foundation for AMF panel shall deemed to be included in the quoted rate.(vi) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
Contract Date: May 29, 2026 Contract Value : 5.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
8.
Housing Urban and Rular Development #11175654 Technical Bid
development of landscaping work of tower of justice in district gurugram (original work) , hsr item 26.1-supplying and stacking at site of work welldecayed farm-yard manure from any available source,approved by the engineer-in-charge including screening through sieve of i.s.designation 16 mm with 5 km lead. , hsr item 26.2-supplying and stacking of good quality top layer garden earth free from debris and weeds, at site including royalty and carriage/lead 5 km (good earthmeasured in stacks will be reduced by 20 % for payment) onlyfor filling of pots and flower beds . 0.00 0.00 0.00 , hsr item 26.4.8-site clearance 8. uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts. , hsr item 26.9.4-turfing lawns with fine grassing ( selection no.1/ bermuda and mexican/neelgiri grass )includingploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying of selection no. 1bermuda doob grass and mexican/neelgiri grass roots, including supplying and spreading of farmyard manure at the rate of 0.60 cum per 100 sqm, maintenance till weed free turf is formed 4. providing and fixing selection no. 1 grass turf with earth 50mm to 60mm thickness and ramming with required wooden tools, rolling with light roller to make the surface smooth and even , hsr item 26.13.4-digging holes in all kinds of soil, and refilling the same, with the excavated earth, mixed with well decayed farmyard manure (cost of well decayed farm yard manure to be paid separately) 4. hole 0.60 metre dia and 0.60 metre deep , hsr item 26.13.3-digging holes in all kinds of soil, and refilling the same, with the excavated earth, mixed with well decayed farmyard manure (cost of well decayed farm yard manure to be paid separately) 3. hole 0.75 metre dia and 0.75 metre deep , hsr item 26.18-supply and planting of disease free healthy , vigorous growing more than 75 cm height permanent shrubs in already prepared pits, supplied in 25 cm x 20 cm poly bags , application of 10 ml chlorpyriphos 20% e.c. term , hsr item 26.20-supply and planting rare and specimen tree plants in already prepared pits (ficus starlight 150 cm height , terminalia 210 cm height, menatalis , michelia champaca hybrid more than 180 cm height, cyprus (golden juniperous ) more than 180 cm height, topiary of 10 to 12 no. well trimmed bolls of more than 30cm size of ficus nuda, ficus retusa,ficus long island , ficus panda more than 180 cm height, golden bottle brush , casurina equistefolia , bottle palm with stem circumference at base more than 40cm ,washingtonia palm of healthy clear stem height below leaf more thant 90 cm ) including , fertilizer and insecticides chlorpyriphos 20 ml per pit, planting of 180cm to 210cm tall sapling in position and flooding with water .specie of plant will be decided by engineer in charge. , hsr item 26.277-providing and displaying bamboo buddhavalley with fresh and healthy 5 to 6 suckers 1.80 m to 2.10mht umbrella type plant well developed in 50 cm cement pot asper direction of the officer-in-charge , hsr item 26.279-providing and displaying bismarckia palm 115 to 180 cm ht., well developed 12 and above good colour fresh and healthy leaves in 40 cm cement pot as per direction of the officer-in- charge , hsr item 26.283-providing and displaying cycus revoluta specimen plant, having 45 to 50 fresh and healthy, leaves having 30cm to 35cm circumference of base stem well developed in 40 cm challi, as per direction of the officer-incharge. , hsr item 26.286-providing and displaying cyprus goldenconical shape 150 to 165 cm ht., with fresh and healthygolden colour foliage in 40 cm cement pot as per direction ofthe officer-in-charge , hsr item 26.292-providing and displaying ficus retusa topiary well developed with fresh and healthy 8 to 10 big ball specific size and shape 180 to 210cm ht in 40 cm cement pot as per direction of the officer-in-charge. , hsr item 26.298-providing and displaying foxtail palm well developed with fresh and healthy foliage of ht. 210 to 240 cm in big 40 cm cement pot as per direction of the officer-incharge. , hsr item 26.303-providing and displaying latania rubrapalm well developed with fresh and healthy foliage 150 to 180cm ht. with 6 to 7 leaves in big 35 cm cement pot as perdirection of the officer-in- charge , hsr item 26.22.2-planting seasonal flower in beds 2. planting flower beds including digging 30 cm deep bed and refilling of beds with excavated soil and fym 0.0508 cum per sqm , fertilizer dap 50 gms and insecticides chlorpyriphos 10ml per sqm , planting of f1 hybrid well bloomed flower saplings to be supplied in polybags at 25cm distance from plant to plant and row to row minimum 15 no . plants per sqm , hsr item 26.28-`supply and planting healthy disease free 30 cm to 45 cm height ground cover of rare species plants .i.e. rasselia, chlorophytum, juniperous prostata, asparagus grass, cuphea chinensis, ipomea, portulacaria (jade plant)zebrina trades cantia etc ) including digging 30 cm deep bed and refilling of beds with excavated soil and fym 0.075cum per sqm , fertilizer dap 100 gms and insecticides chlorpyriphos 10ml per sqm , planting of saplings of rare specie of plants to be supplied in 20cm x 20cm ` polybags with full of leaves and in healthy condition at 30cm distance from plant to plant and row to row minimum 15 no. plants per sqm ,and watering , hsr item 26.34-planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth, mixed with farm-yard manure, supplied at the rate of 1.62 cum per 18 sqm, dap 0.6kg, chlorpyriphos 20%ec@ 0.20 litre per 18 sqm and supplying and planting hedge at 30 cm apart in two rows @ 202 no. well trimmed bushy ,multi-branched ,30 cm to 45 cm in height plants to be supplied in 15 cm x 15 cm poly bags per 18 sqm , hsr item 26.52-preparation of mounds of various size and shapes including supply of good earth, in layers not exceeding 20 cm in depth, breaking of clods, watering each layer, dressing etc, lead up to 50 m and lift up to 1.5 m complete as per directions (excluding cost of good earth and manure which will be supplied separately.) , hsr item 26.56-providing and fixing of haridwar pebbles( white river stone size of 2` to 2.50`dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc. as per direction of office in charge. , hsr item 26.77-supply of well grinded in powder form deoiled neem cake in packed gunny bags , hsr item 26.100-providing and displaying of araucaria cookie plant, having ht. 1.50 m to 1.80 m, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 30 cm size of earthen pot/plastic pot and as per direction of the officer-in-charge. , hsr item 26.524.9-`providing and stacking winter seasonal f1-hybrid seedlings/cuttings at site of work well developed and healthy free from disease in per tray and each tray having 100 nos. plants as per direction of the officer-in-charge.` 9. chrysanthemum double , hsr item 26.524.21-`providing and stacking winter seasonal f1-hybrid seedlings/cuttings at site of work well developed and healthy free from disease in per tray and each tray having 100 nos. plants as per direction of the officer-in-charge.` 21. marigold inca hybrid , hsr item 26.525.6-`providing and stacking summer and rainy f1-hybrid seasonal seedlings at site of work well developed and healthy free from disease in per tray and each tray having 100 nos. plants as per direction of the officer-in-charge.` 6. kochia , hsr item 26.41.3-supplying and display seasonal flowers of f1 hybrid quality in earthen pots at site of work, as specified by engineer-in-charge including cost of pot. 3. supply and planting f1 hybrid seasonal plants in well bloomed flowering stage in 30 cm size of pots , hsr item 26.38.3-supply of well burnt cylindrical earthen pots and filling of the following size empty pots with mixture of good earth and manure in the ratio of 2:1 (two part of good earth and one part of manure)and placing them on appropriate place i/c carriage of earth, manure and pots up to 50 metre, as per direction of officer in charge. 3. 25 cm size of pots filled to full volume , hsr item 26.38.4-supply of well burnt cylindrical earthen pots and filling of the following size empty pots with mixture of good earth and manure in the ratio of 2:1 (two part of good earth and one part of manure)and placing them on appropriate place i/c carriage of earth, manure and pots up to 50 metre, as per direction of officer in charge. 4. 30 cm size of pots filled to full volume , hsr item 26.39.2-providing circular /square cement concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4(1 cement:2 coarse sand:4 graded stone aggregate 6 mm nominal size), including required from work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows and height, all complete as per direction of officer-in-charge. filling 2/3rd volume with mixture of good earth and screened , hsr item 26.39.3-providing circular /square cement concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4(1 cement:2 coarse sand:4 graded stone aggregate 6 mm nominal size), including required from work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows and height, all complete as per direction of officer-in-charge. filling 2/3rd volume with mixture of good earth and screened manure in the ratio 2:1. 3. cement pots size 45cm x45cm , hsr item 26.40.5-providing 1st quality heavy duty plastic pot with base plate at site of work, filling with mixture of good earth and screened manure and coco peat in the ratio 2:1:1 5. 35 cm size of pots filled to 2/3rdvolume , hsr item 26.44.2-supplying and display indoor decorative plants with fresh foliage,60cm-75 cm in height` 3-4 stems per pot, full of leaves, suitable for earthen pots / plastic pots size 30cm dia and 30cm deep(average size),and displaying indoor including the cost of material ( garden soil, coco peat, fym in2:1:1 proportion),with ,pvc plate. complete in all respects including cost of pot . 2. in earthen pot , hsr item 26.46-`supplying and display specimen pot plant of raphis palm , cephorthia palm 150 cm,areca palm 150-180 cm and similar high quality plants of croton petra 3 plants each in 45 cm plastic pots with plastic plate for indoor display at site of work. with fresh foliage,90 cm- 180 cm in height` 6-8 stems per pot, full of leaves, ,and displaying indoor including the cost of material ( garden soil, coco peat, fym in 2:1:1 proportion),with ,pvc plate. complete in all respects.` , hsr item 26.48-supplying decorative plant in 30 cm cement pots for outdoor display at site of work with fresh foliage of 60cm-75 cm in height` 3-4 stems per pot, full of leaves, suitable for earthen pots / plastic pots size 30cm dia and 30cm deep(average size) and displaying including the cost of material ( garden soil, coco peat, fym in2:1:1 proportion),with ,pvc plate. complete in all respects , hsr item 26.50-supplying and display of specimen pot plant of cyprus , ficus starlight, topiary of ficus retusa and similar high quality plants in 45 cm cement pots with plastic plate for outdoor display at site of work. with fresh foliage,105 cm- 150 cm in height, 3-4 stems per pot, full of leaves, ,and displaying indoor including the cost of material ( garden soil, coco peat, fym in 2:1:1 proportion),with ,pvc plate. complete in all respects. , hsr item 26.67.1-providing and fixing vertical garden panels on aluminium tube (50 x25 x 1.5 mm) frame, or 18.85 kg per sqm weight ms angle and ms pipe frame fixed on wall, with growing media of coco peat, perlite and vermiculite 2:1:1, amended with fertilizers and plants as specified by the engineer in charge including drip irrigation of netafem, harvel, hunter, rain bird, jain irrigation systems minimum bis standard material , planter used should be virgin plastic, , plants supplied should in coco peat and vermiculite medium and every plants should be of permanent decorative quality height of plants should be 30cm to 45 cm .complete. 1. indoor vertical garden , hsr item 26.67.2-providing and fixing vertical garden panels on aluminium tube (50 x25 x 1.5 mm) frame, or 18.85 kg per sqm weight ms angle and ms pipe frame fixed on wall, with growing media of coco peat, perlite and vermiculite 2:1:1, amended with fertilizers and plants as specified by the engineer in charge including drip irrigation of netafem, harvel, hunter, rain bird, jain irrigation systems minimum bis standard material , planter used should be virgin plastic, , plants supplied should in coco peat and vermiculite medium and every plants should be of permanent decorative quality height of plants should be 30cm to 45 cm .complete. 2. outdoor vertical garden , hsr item 33.6.1.1-boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in is: 2800 (part i), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipments, tools, plants and machineries required for the job, all complete as per direction of engineer-in-charge, up to 90 metre depth below ground level. 1.1. all types of soil 300 mm dia , hsr item 33.8.2-supplying, assembling, lowering and fixing in vertical position in bore well, unplasticised pvc medium well casing (cm) pipe of required dia, conforming to is: 12818, including required hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of engineer -in-charge. 2. 150 mm nominal size dia , hsr item 22.88.6-providing and fixing g.i. pipes complete with g.i. fittings and clamps, i/c cutting and making good the walls etc. internal work - exposed on wall 6. 50 mm dia nominal bore , hsr item 24.5.1.2-miscellaneous items 1.2. supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with pvc for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with is:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of engineer- in-charge. submersible copper cable 3 core 2.5 sqmm , hsr item 33.16.2-providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 2. 150 mm dia , hsr item 33.17.2-providing and fixing m.s. clamp of required dia to the top of casing/ housing pipe of tube well as per is: 2800 (part i), including necessary bolts and nuts of required size complete. 2. 150 mm clamp , hsr item 33.18.2-providing and fixing bail plug/ bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 (part i). 2. 150 mm dia , hsr item 22.99.4.1-providing and fixing gun metal nonreturn valve of approved quality (screwed end) : 4.1. 50 mm nominal bore horizonta , hsr item 33.19-development of tube well in accordance with is : 2800 (part i) and is: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by `v` notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of engineer-in-charge. , ns item -supply and installation isi mark 3 hp single phase submersible motor with pump of lubi, ksb, crompton, texmo etc (along with nylon rope) , ns item -supply and fixing isi mark panel board of 3 hp of bch, cuttler hammer, landt, boparai etc. with lock and key steel box. , ns item -supply and fixing, 16 mm aluminium cable of r.r./havells/fenolux make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
9.
Public Administrative Department #11142241 AOC
Construction And Carry Out Ancillary Works For Urban Ayushman Health Temples (Uhwc) In Porta Cabins At 14 Places In The Jurisdiction Of Thane Municipal Corporation.-1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. :Means Bd.A.1 Page No.259 2 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means 3 Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. 4 Transportation of excavated material including loading and unloading etc. complete. (c) lead up to 5 km) 5 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. 6 Providing soling using 80 mm size trap metal in 15 cm. Layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge. 7 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 8 Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 9 Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Providing and fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use).Spec. No As director by engineer incharge. Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Spec. No As director by engineer incharge. Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. 14 Painting letters upto 20 centimetre height including cost of brushes, coir brushes dusting, cleaning etcetera complete. Spec. No. As Directed By Engineer In Charge. Only For Road Side Furniture. Spec .No. MORTH 801 15 Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573. 16 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. cover of 75 Kilogram with lid and frame fixed in cement concrete.. Spec. No. 17 Providing and laying in trenches 25 mm dai. UPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 18 Providing and fixing hume pipe septic tank 900mm diameter with vent pipe and cap including necessary (including excavation and laying) 19 Providing and making ISI Mark ferrule connection of 25mm dia.to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. 20 Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters 21 Supplying, erecting, testing and commissioning of minimum three and above star rated centrifugal water pump (monoblock),230 V,single phase,50 Hz,AC.supply of 0.375kw/0.5 HP with discharge 36/9 lpm for head of 6/21 m & 25 mm suction /25 mm delivery pipe on provided CC foundation as per specification no.WP.CGP. 22 Supplying, installing and testing earthing with copper earth plate 30 x 30 x 0.315 cm complete with all accessories of copper materials and recording the results as per specification no.Ea-EP Supplying, & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 Kg.capacity cartridge type conform to IS 2878/15683 complete erected with necessary clamp made from 50 x 6 mm M.S. flat with nut & bolts rounded in wall complete. Supplying, & erecting Hand dryer machine having speed jet of warm air with low noise blower to quick dry wet hands,power 1800 W,voltage 230V,50 Hz.Automatic cut off after 5-10 second. Providing,Supplying and fixing electrical meter with all necessary accessories,required cable for connection from main supply including required permission from MSEDCL,TORRENT and Local authorities.(The contractor shall submit the original receipts of payments made to MSEDCL, Torrent Power co.The payments will be made as per the actual expenses made by contractor for each permission and purchasing of electric meter.) Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Supplying and laying (including excavation) 50 mm outside dia double wall corrugated pipe (DWC) of HDPE for enclosing cable below ground/road surface to required depth completed Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Providing, Supplying and installation of Porta Cabin Fabricated at Factory Scope of work per cabin shall includes as follows 1. Specification mentioned as below 2. Internal and external arrangement of cabin as per drawings as attached 3. Works of Plumbing, sanitary, electrification, CCTV 4. Furniture as below a. Executive Chairs (as per sr.no.3) - 3 nos, b. Visitor chair (as per sr.no.4) - 6 no c. Two seater chair (as per sr.no.5) – 2 Nos d. Three seater chair (as per sr.no.6) – 5 Nos e. Patient Examination Couch/Table (as per sr.no.8) – 2 Nos f. Storage Cabinet (as per sr.no.9) – 1 Nos g. Table (as per sr.no.10) – 4 Nos h. Table (as per sr.no.11) – 1 Nos i. Medical Store Racks in pharmacy room (as per sr.no.12) – as per drawing j. Trash Bin (as per sr.no.13) – 6 Nos k. Seating tools (as per sr.no.7) – 6 Nos Detailed Description and Specification: Unit Size – L x B x Ht = 30 ft x 20 ft x 9 ft (Clear internal Height) Cabin should be structurally stable and suitable to meet severity of climatic conditions. Sustainable in wind condition of 55m/s- in Seismic zone IV and ambient temperature range (-) 40 degree C to (+) 50 degree C. Bottom Frame 80 x 40 x 2mm GI Rectangular Hollow Pipe (Apollo Make) Stiffener Bottom 50 x 50 x 2mm GI Rectangular Hollow Pipe (Apollo Make) for Shorter Span and 80 x 40 x 2mm for longer Span making the grid of 2ft x 2ft. Please note Base frame shall be quoted with special type of anticorrosive paint to avoid rusting and for better life (i.e. Black Coal Tar Epoxy Paint) Top Frame 80 x 40 x 2 mm GI Rectangular Hollow Pipe (Apollo Make) Stiffener (Top Frame) 50 x 50 x 2mm GI Rectangular Hollow Pipe (Apollo Make) for Shorter Span and 80 x 40 x 2mm for longer Span making the grid of 2ft x 2ft. Please note Base frame shall be quoted with special type of anticorrosive paint to avoid rusting and for better life (i.e. Black Coal Tar Epoxy Paint) Paneling Outside Outside Wall of the cabin shall be made from 16 guage GI sheet with solid color of approved shade, fitted on inside GI pipe framing making the grid of 2ft x 2ft. Paneling Inside Inside wall of the cabin shall be made from 3 MM Thk ACP sheet with aluminum foil thickness of 0.25 mm with solid color of approved shade fitted on inside Gl pipe framing making the grid of 2ft x 2ft. All the ACP joints shall be filled with Black silicon. Wall Panels shall be completely insulated with Glass wool of 48 kg/m3 Density and slab thickness 50mm. Corners Pole 72 x 72 x 3.2mm GI Rectangular Hollow Pipe (Apollo Make) with black coal tar epoxy coating Plumbing Arrangement UPVC concealed internal plumbing system shall be provided with all necessary inlet and outlet points as per the Drawing. External water connection shall be Provided by TMC. Drinking Arrangement Providing and Fixing branded water purifier of make like Aquaguard, Kent, LG or equivalent with all necessary connections, fittings accessories with storage arrangement etc. complete Sanitary Fittings All plumbing and sanitary fittings such as Ceramic Western Commode with seat cover, Ceramic Indian Commode, Ceramic urinal with push pillar cock, Ceramic Wash Basin, Wash basin Push Pillar Cock shall be of brand like Kajaria, Hindware, Paryware or equivalent. All western Toilets must be equipped with jet Spray, 2 in 1 Taps and Flush Tank. Accessories for PWD persons shall be provided in all toilets. (Excluding External Sewerage Connection). Roof Outside Roof Slope 1:2 one way 126 Roof shall be made from 1.2 mm 120 GSM GI sheets of Jindal make, which shall be fully welded and sloped to avoid leakage. All the roof joints shall be covered with 75mm Butyl Vinyl Tape. Roof shall be covered with Heat Resistant paint to maintain low temperature inside the cabin. Roof Gutter Specially designed gutter section shall be provided to drain water at the single side of the cabin. This shall be made from 1.2 mm 120 GSM GI sheet Jindal make including fitting arrangement. False Ceiling False Ceiling shall be made from 3 mm Thk ACP sheet with Aluminium foil thickness of 0.25 mm with solid colour of approved shade fitted on inside GI pipe framing making the grid of 2ft x 2ft. All the ACP joints shall be filled with Black silicon. Flooring Flooring shall be made from 18 mm High Strength Bison board/ Cement fibre sheet, which is covered with 2 mm PVC vinyl flooring for cabin. For toilet Cement sheet shall be covered by 10 mm thick 1 X 2 ceramic tiles which shall be fixed by using tile adhesive and cement mixture of at least 50mm Thk. Doors & Door frame Main Door Flush door 32 mm thick waterproof material with 4mm Glass as per approved design and drawing and door frame shall be made from aluminium Section. Locking arrangement along with D Handles in SS 304, door closer, door stopper etc. Door Size: 5’x 6’ Internal doors shall be sliding doors/ flush door of size as per drawing and as per the specifications decided by engineer-in charge Toilet Door and door frame shall be made from aluminium frame with 4mm Glass and ACP including locking arrangement, Handles in SS 304, Door Size: 2’-6’’ x6’ Windows Powder coated aluminium Two Track sliding windows with 4 mm tinted Glass. Size of windows as per drawings. M.S. Grill of weight @ 20 kg per sqm shall be provided to all windows/louvered window from outside. Curtains of good quality and curtain rod/track with fixtures shall be provided from inside of windows. Insulation False Ceiling and Wall Panels shall be completely insulated with Glass wool of 48 31 Providing, Supplying and installation of Porta Cabin Fabricated at Site Scope of work per cabin shall includes as follows 32 Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 Kilogram/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm, skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 33 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 34 Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 35 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 36 Testing :- Compressive test of C.C.Cube 37 Provide and supplying Executive Chairs A generously cushioned, molded PU seat combined with breathable mesh fabric, Crafted from strong and durable Polyamide (Nylon) featuring a reinforced mesh back, chair equipped with BIFMA Certified Class-4 Hydraulic Gas Spring and BIFMA Certified 60mm Wheel Castors. Chair having 3 years warranty (Executive chairs) / or equivalent / as Directed by Engineer Incharge. Key Features Colour : GREY / Black Material : Metal Dimensions : 64D x 61W x 119H Centimeters Size : Standard Back Style : Mesh Back Special Feature : Adjustable Lumbar, Adjustable Height, Adjustable Arm Rest, Adjustable Head Support Seat Material Type : Breathable Microfiber Cloth Covered in PU Foam 38 Providing and supplying visitor chair having size Depth- 62cm, width-55cm, height- 80cm & seat height 45 cm. (+/- 2cm ), having seat & back, shall be made up of 1.2 cm hot pressed plywood, approved tapestry upto Rs.300/m and mould polyurethane foam with P.V.C. lipping all around etc. complete. The chair shall be provided with two one piece armrest made of polypropylene. The chair shall be supported by cantilever type powder coated tubular frame dia 2.54cm x 14 B G M.S.E.R.W. tube. All aluminium steel component shall have Epoxy Polyster Powder Coated. The chair shall be Ergonimc Dry film thickness shall be more than 45 Micron. And as directed by Architect in charge. The over all appearance of the product shall be as per photograph. All metal work shall be Epoxy Polyster Powder Coated and as directed by Architect in 39 Public Seating Chair. - 2 Seater Providing and Fixing 2 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish with 1 year warranty etc complete as directed by engineer in charge.. 40 Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. 41 Seating tool for Lab and Class-IV Providing and fixing 4 legged Lab stool, Legs made of 16 Guage 45 MM Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge. 42 Providing and supplying examination couch. This examination couch features an adjustable backrest that can be easily operated using a gas spring system. The twosection foam-padded top provides added comfort for patients during examinations. It is equipped with three drawers and three cabinets, offering ample storage space for medical equipment and supplies, keeping everything organized and easily accessible. A tray for the B.P. apparatus is conveniently placed near the headrest, ensuring easy access for medical professionals. The couch is finished with pre-treated epoxy powder coating, making it durable and easy to clean, while also ensuring resistance to corrosion Designed with a carrying capacity of 150-180 kg. etc complete. as directed by engineer in charge. Key Features Adjustable Backrest: The backrest is adjustable using a gas spring system, providing flexibility for various examination positions. Foam Padded, Upholstered Top: Offers comfort and support during patient examinations. Ample Storage: Equipped with three drawers and three cabinets to store medical supplies and equipment. BP Tray: A tray near the headrest for easy access to BP apparatus. 43 Providing, supplying and installing the cabinet, dimensions of 1200mm (W) x 1660mm (H) x 450mm (D) and is constructed from prime quality 0.8mm thick CRCA steel for the body panels and shelves. The shelves are adjustable in height and have a uniformly distributed load capacity of 50kg per shelf. The vertical sides feature continuous slots for mounting shelves at variable heights. The entire carcass is finished with a 50 ±10 microns epoxy polyester powder coating. The facia of the cabinet consists of metal shutters with metal borders, incorporating toughened glass panels. The handles are Dshaped in an aesthetically pleasing design with a stainless steel (SS) finish. The locking mechanism uses a metal cam lock for security. Additionally, the cabinet is equipped with adjustable levelers featuring plastic bases, allowing height adjustments of up to 15mm.This furniture is built according to the specifications and samples approved by the client. It meets the required certifications including ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, BIS standards, and is a BIFMA Gold certified member. The product comes with a 5-year warranty. Installation and other details are as directed by the engineer in charge. 44 Providing & Fixing of HNI Make table of Size. The Worktop shall be made of 25mm Prelam particle Board of Grade II , Type-II as per IS:12823 and backing laminate of 0.6mm All the exposed edges are finished with 2mm thick PVC lipping machine pressed. The above furniture should be as per specification with 3 years warranty etc. sample approved by client. TABLE SIZE :- W1060mm x D600mm x H750 mm -1 No W900mm x D300mm x H750 mm – 1 No W600mm x D450mm x H750 mm – 2 No As Directed by Engineer Incharge 45 Providing & Fixing of HNI Make table of Size. The Worktop shall be made of 25mm Prelam particle Board of Grade II , Type-II as per IS:12823 and backing laminate of 0.6mm All the exposed edges are finished with 2mm thick PVC lipping machine pressed. Legs are made of powdered coated steel 50mmx 50mm Section. Cross Member are in CRCA steel and the Beam is made of MS of 1.5mm thickness in powder coated finish of 50 microns thickness. The above furniture should be as per specification with 3 years warranty etc. sample approved by client. TABLE SIZE :- W1200xD700xH740mm As Directed by Engineer Incharge 46 Providing and supplying adjustable MS storage rack having size 1200 mm to 1800mm x 300 mm x 1600 mm including all transportation upto site etc complete as directed by engineer in charge. Key features 1. Material  Frame : Mild steel (MS) powder coated  Shelves: Cold-rolled steel (CRCA) or galvanized  iron (GI) 2. Angle Specifications  Size 40 x 40 x 2.50 mm  Length : Standard lengths of 6 feet, 8 feet, or 10 47 Providing and supplying trash bins with a maximum height of 450mm 35 - 40 liter, made of high-quality molded plastic for durability and ease of maintenance. The bins shall be equipped with a functional lid mechanism and shall be provided as per the approved selection and design. The work shall be carried out as directed by the Engineer-In-Charge etc complete . 48 Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. 49 Providing and Laying M60 grade cement concrete of approved mix design with avg. Flextural strength of 4.4 MPa in 3 days from R.M.C. plant incld. use of micro silica/alcofine, approved make super plastiser and retarder, fibriliated 100 % virgin polypropylene fibres, fly ash and transported by transit mixer and placing at work site. Compacting, finishing, initial curing by approved curing compound/contractors water and tarring the sides of slab with hot bitumen as specified and as directed (w/c ratio 0.28 max.). (vatta for curing will be paid separately) for Ultra thin White Topping (UTWT) pavement. etc completed. Providing second class Burnt Brick masonry with conventional/I.S .type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete Providing structural steel work in single stanchions composed of R.S.J. Channel etc. with caps, bases, mild steel plated, angle brackets, cleats, gusset plates, anchor bolts etc. as per detailed designs and drawings or as directed including cutting, fabrication, hoisting, erecting fixing in position, making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it two. coats of oil painting approved quality and shade etc. complete. Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meter made out of 4 mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity microprismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorized distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminum-Zinc alloy (55% aluminum 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram) Providing Excavator (JCB JS 80 or equivalent) of 0.9 Cum etc complete Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec. One Number: As directed by Engineer- in-charge. Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing and laying Cast in situ/Ready Mix cement concrete M-15 trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing tuck pointing with cement mortar 1:3 for stone/Brick masonry including scaffolding and curing etc. complete. Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. Transportation of excavated material including loading and unloading etc. complete. ( (c) lead up to 5 km) Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Providing soling using 80 mm size trap metal in 15 cm. Layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer in charge. Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineerin- charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Providing and fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use).Spec. No As director by engineer in charge. Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Spec. No As director by engineer incharge. Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Painting letters upto 20 centimetre height including cost of brushes, coir brushes dusting, cleaning etcetera complete. Spec. No. As Directed By Engineer In Charge. Only For Road Side Furniture. Spec .No. MORTH 801 Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573. etc
Contract Date: May 21, 2026 Contract Value : 4.09 Crore
Local Bodies No of Bidders 2
Maharashtra View Result →
10.
Power #11110319 Technical Bid
Tender for Rate Contract For Procurement Of Material That May Be Required During The Emergencies For The Year 2026-27 In Respect Of Ed-3Rd , Supply Of , 50 Mm² Ab (Ht) Cable (3X50 + 1X70 Mm²) Xlpe(11 Kv, 3C + Earth) , 70 Mm² Ab (Ht) Cable (3 X 70 + 95 Mm²) Xlpe(11 Kv, 3C + Earth) , 120 Mm² Ab (Ht) Cable (3X120 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 150 Mm² Ab (Ht) Cable (3X150 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 185 Mm² Ab (Ht) Cable (3X185 + 1X95 Mm²) Xlpe(11 Kv, 3C + Earth) , 11 Kv Heat Shrinkable Outdoor Cable Termination Kit Upto 50- 95 Sqmm ( 3 Core) , Heat Shrinkable Outdoor Cable Termination Kit Above 120 To 185 Sqmm ( 3 Core) , Mid Span Straight Through Jointing Kit For 11 Kv Abc 120 -185 Sqmm , 35 Mm² Ab (Lt) Cable ( 3 X 35 + 1 X 16 + 1 X 25 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 50 Mm² Ab (Lt) Cable ( 3 X 50 + 1 X 16 + 1 X 35 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 70 Mm² Ab (Lt) Cable ( 3 X 70 + 1 X 16 + 1 X 50 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 95 Mm² Ab (Lt) Cable ( 3 X 95 + 1 X 16 + 1 X 70 Mm²(Insulated Messenger)) Xlpe (1.1Kv, 3+1 C, Al) , 120 Mm² Ab (Lt) Cable ( 3 X 120 + 1 X 16 + 1 X 70 Mm²) Xlpe (1.1Kv, 3+1 C, Al) , Mid Span Straight Through Jointing Kit For 1.1 Kv Abc 95-150 Sqmm , Mid Span Straight Through Jointing Kit For 1.1 Kv Abc 35-70 Sqmm , 70 Mm² Single-Core Cable, 1.1Kv Grade, Xlpe Un-Armoured Frls Type , 95Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 120 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 150 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 185 Mm² Cable, 1.1Kv Grade, Xlpe Un Armoured Frls Type , 240 Mm² Single Phase Cable,1.1K V Grade, Xlpe Un Armoured Frls Type , 300 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 400 Mm² Single Phase Cable,1.1K V Grade, Xlpe Un Armoured Frls Type , 500 Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 630Mm² Xlpe Lt Cable Single Core, Un-Armoured, Frls , 10 Mm² Cable (2C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 16 Mm² Cable (2C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 10 Mm² Cable (4C), 1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 16 Mm² Cable (4C),1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type , 25 Mm² Xlpe Lt Cable 4 Core, Armoured, Frls , 35 Mm² Xlpe Lt Cable 4 Core, Armoured, Frls , Single Core 1 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 1.5 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 2.5 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 4 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , Single Core 6 Mm² Cable Copper Wire , 1.1 Kv Grade, Isi, Frls. , 11 Kv, 3- Core Xlpe 35 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 50 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 70 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 120 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 150 Mm² Round Wire Armoured, Frls Cable , 11Kv, Three Core 185 Mm2 Aluminium Round Wire Armoured Xlpe Cable , Frls , 11 Kv, 3- Core Xlpe 240 Mm² Round Wire Armoured, Frls Cable , 11 Kv, 3- Core Xlpe 400 Mm² Round Wire Armoured, Frls Cable , 11 Kv End Termination For 3C 120- 185 Mm² , 11 Kv End Termination For 3C 240 To 400 Mm² , 11 Kv Straight Through Jointing Kit Upto 50-95 Mm² , 11 Kv Straight Through Jointing Kit Upto 120-185 Mm² , 11 Kv Straight Through Jointing Kit Upto 240-300 Mm² , 11 Kv Straight Through Jointing Kit Upto 400 Mm² , Lt Distribution Box For 25 Kva Dtr With 40 annual periodical maintenance Mccb 3P 16 Ka For Incomer & 25 annual periodical maintenance Mccb 3P 16 Ka/10 Ka 1 No. Each (=2No.) For Outgoing Circuits . , Lt Distribution Box For 63 Kva Dtr With 100 annual periodical maintenance Mccb 3P 16 Ka For Incomer & 100 annual periodical maintenance Mccb 3P 16 Ka 1 No. And 63 annual periodical maintenance Mccb 3P 16 Ka 1 No.S For Outgoing Circuits , Lt Distribution Box For 100 Kva Dtr With 160 Mccb 3P 16 Ka For Incomer & 100 annual periodical maintenance Mccb 3P 16 Ka 2 No.S For Outgoing Circuits , Lt Distribution Box For 200 Kva Dtr With 315 annual periodical maintenance Mccb 3P 25 Ka For Incomer & 160 annual periodical maintenance Mccb 3P 16 Ka 3 No.S For Outgoing Circuits , Lt Distribution Box For 250 Kva Dtr With 400 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 1 No. And 160 annual periodical maintenance Mccb 3P 16 Ka 2 No.S For Outgoing Circuits , Lt Distribution Box For 400 Kva Dtr With 630 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 4 No.S For Outgoing Circuits , Lt Distribution Box For 400 Kva Dtr With 630 annual periodical maintenance Mccb 3P 36 Ka For Incomer & 200 annual periodical maintenance Mccb 3P 16 Ka 4 No.S For Outgoing Circuits , Temporary Lt Fuse Set For Distribution Transformers (Customised) As Per Kpdcl Drawing No. Ce/P&P/Drg/2023/Ltfs/001 (Enclosed) , 11Kv Polymeric Composite Disc Insulator 12Kv,Min Failing Load 45Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm Nos , 11Kv Polymeric Composite Pin Insulator 12Kv, 5Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , 16 Kn Polymer Shackle Insulator , G.I Mukey For Shackle Insulators With Bolt Of (50X8)Mm , Gi U-Clamps For Shackle Insulator 50X8 Mm, (3.14 Kg/Mtr), 258 Mm , Gi U-Clamps For Shackle Insulator 50X8 Mm, (3.14 Kg/Mtr), 369 Mm , 11 Kv Link Set Heavy Duty With Copper Blade Size Of 14 Inch, 50 X 6 Mm, Female Contact Of Copper 6 Mm Thickness, With Post Insulator Of 10 Kn , 11 Kv Go, Ab Switch 3-Phase, 3-Pole,200 Amp, Vertical Type Set , 11 Kv Horn Gap Fuse Set 3 Phase 200A Set , Pg Clamps For 30 Mm² Acsr Conductor , Pg Clamps For 50 Mm² Acsr Conductor , Pg Clamps For 100 Mm² Acsr Conductor , Suspension/Tension Clamp With Eye Hook , Gi Pole Support Clamp Including Gi Nut And Bolts For 11 Mtr Pole With Size - 50X8x376 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 9 Mtr Pole With Size - 50X8x376 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 8 Mtr With Size 50X 8X 328 Mm , Gi Pole Support Clamp Including Gi Nut And Bolts For 8 Mtr Or 9 Mtr Plain Cement Concrete With Size 50X8x441mm , Cable Tie (Each Packet Contains 100 Nos.) , Cable End Caps , Insulating Piercing Connectors Of Sizes , 11 Kv Ipc (Insulation Piercing Conductors)For Bare To Cc(Covered Conductor) Connection , 11 Kv Ipc For Covered Conductor To Covered Conductor Connection , 33 Kv Tension Clamps With Bail And Ipc (Insulation Piercing Conductors) , 33 Kv Ipc (Insulation Piercing Conductors)For Bare To Cc(Covered Conductor) Connection , 33 Kv Ipc For cement concrete To cement concrete Connection , 33 Kv Ipc With Aluminium Bail For Earthing , Main Single Phase Service Distribution Box (Pole Db) Along With Mccb /Mcb As Per Rec Drawing. The Db Should Have Bottom Entery Of Cable With Proper Glands/Grommets-Safety Screws And Back Clamp Suitable For 11/9/8 Mtr St Pole Or 9/8 Mtr Plain Cement Concrete Poles With Nuts/Bolts , Main 3 Phase Distribution Box Ip 54 (Pole Db) Made From 20 Swg Crca Ms Sheet By Deep Drawn Method With Powder Coating. Internal Size Of The Box Shall Be 225Mm X 285Mm X 120Mm Used For Connection Through Abc Line And For Giving Connections To The Consumers 3Phase-1 Incoming 4 Outgoing I/C- 1, O/G-2-4 (200 A, 0.415 Kv) For Ryb Phase. The Db Should Have Bottom Entery Of Cable With Proper Glands/Grommets-Safety Screws And Back Clamp Suitable For 11/9/8 Mtr St Pole Or 9/8 Mtr Plain Cement Concrete Poles With Nuts/Bolts , Lt Line Spacers 3 P ,4 Wire , Lt Line Spacers 2 P ,3 Wire , Gapless Surge Arrestor,9 Kv ,10 Ka ,La With Polymer Housing, Stn. Type , 3-Ø, 4-Wire Trivector Meter (Prodigy ) With Suitable Ring Type Ct 200 annual periodical maintenance (Net Meter Enabled) , Single Phase Smart Energy Meter 5-30 Amp/ 10-60 Amp, Dlms Complaint Of Accuracy Class 1.0 , Three Phase Smart Energy Meter 20-80 Amp/, Dlms Complaint Of Accuracy Class 1.0 , Polypropylene Weather Proof Outdoor Type Meter Box For Single Phase Meter Along With Zinc Plated Clamps , Polypropylene Weather Proof Outdoor Type Meter Box For Three Phase Meter Along With Zinc Plated Clamps , Polypropylene Weather Proof Outdoor Type Meter Box For 4 Single Phase Meter Along With Zinc Plated Clamps , Gi Barbed Wire For Anti Climbing , Danger Plates With Clamps , Anti-Climbing Device With Clamps , Cemical Earthing Complete , Earthing Mat (Gi Flat 50 Mm X8 Mm)/(75 X10)Mm/(75X8)Mm , Gi Pipe 40 Mm 3 Mtr Long For Earthing , Earthing Electrode ( 3M Long) 20 Mm Dia. , Gi Strip 25X3 Mm , Galvanized Earthing Strips 50Mm X3mm. , Red Oxide , Aluminium Paint , Galvanized Nuts And Bolts , Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator(2No..), Anchor Plate (200X 200 X 6 Mm), Nut-Bolts, 2 No. Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7/3.15 Mm Dia Gi Stranded Wire Complete (11 Kv) , Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator(2Nos.), Anchor Plate (300X 300 X 8 Mm), Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7/3.15 Mm Dia Gi Stranded Wire Complete (33 Kv) , Gi V Cross-Arm With Top Bracket Of Sizes , Gi Channel X-Arm And Braces Of Sizes , Gi Extension Riser Of Sizes , Gi Wire 6 Swg & 8 Swg , Guard Netting (For 52 Mtr Span) , Aluminium Jointing Sleeves 100 Sqmm , Aluminium Jointing Sleeves 50 Sqmm , Aluminium Jointing Sleeves 30 Sqmm , Suspension Fitting (2 Bolt) For 11 Kv Line , Tension Fitting (4 Bolt) For 11 Kv Line , Suspension/Tension Clamp With Eye Hook , Earth Wire 7/4 Sqmm , 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation, Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accesories 4 Way Distribution Service Pillar. , 3 Phase, 415V, 1No Of 250 Amps Incoming 3 Tp Mccbs (Breaking 36Ka) Fitted Withoutgoing 03 No 100 Amps Sp Mccbs, 1No.100Amps 3 Pole Mccb For Outgoing Lt Cables, Distribution Feeder Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 4P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accesories 4 Way Distribution Feeder Pillar. , Fire Extingiusher Co₂ Type Of 4.5 Kg Capacity For Control Room , 3 Sand Bucket Fire Extingiusher , Gum Boots With Steel Toe Of Sizes , Winter Jacket- Coat Ecc Consists Of Three Independent Components That Is Wind Cheater ( Waterproof ), Insulating Layer And Waist Coat ( Sleeve Less ), Three Layer Waterproof Breathable Fabric, Dual Shade Og/ White, Material Of Insulating Layer- 1. Batting Polyester, 100 Gsm, 2. Fabric Nylon Knitted Aluminized, 3. Fabric Nylon 75 Gsm White, Material Of Waist Coat- Double Layer Bonded Polyester Fleece , Safety Vest - Reflective Luminous Garments - High Visibility Warning Garments With Synthetic Slide Fasteners, Fluorescent Yellow, Width Of Retro Reflective Material For All Types Of Garments (Minimum) 50 Millimeter , Non-Contact Voltage Detector, Upon Detection, Tip Glows And Beeper Sounds, Cat Iv 1000 V For Added Protection, Expanded Range: 90 V To 1000 V Ac Or 200 V To 1000 V Ac, Battery Cell Operated (2 Aaa Or Standard), Voltbeat Technology And Continuous Self-Test , Safety Helmet- Quality Of Shell High Quality, High Impact, Light Weight,Tough, Conformity To Specification- Is 2925:Latest ,En 397 Certified , Safety Rubber Gloves Up To 15 Kv As Per Iec Standard , Safety Belt/Harness With Shock Absorber , Safety Shoes Of Sizes -Personal Protective Equipment - Safety Footwear As Per Bis Specification No Is 15298 ( Part 2 ): 2016, Toe Cap- ( Steel ) Metallic, Insole, Classification- Class I ( Footwear Made From Leather And Other Materials, Excluding All-Rubber Or All-Polymeric Footwear ) With Different Sizes, Slip Resistant- As Per Clause 5.3.5.4 Of Is 15298 ( Part 2 )- Slip Resistance On Ceramic Tile Floor With Nals And On Steel Floor With Glycerine. , 11 Kv Earthing/Discharging Rod (Set Of 3 Rods) Set With Minimum 20 Sqmm Cable And U-Clamp , Battery Operated 12 Kv Voltage Detector (Cpri Tested) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds , Alumunium Ladder 2*20 (Double Ladder) 3 Mm Thick Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope And Pulley Arrangement , Alumunium Ladder 2*15 (Double Ladder) 3 Mm Thick Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope And Pulley Arrangement , Aluminium Ladder 2*10 Ft Long, Anti Corossion, Anodised, Bottom Rubber, Sliding Type With Rope , Bamboo Ladder 18 Ft Long, Natural Bamboo Finish, Min Load Bearing Capacity Of 150 Kg , Bamboo Ladder 20 Ft Long, Natural Bamboo Finish, Min Load Bearing Capacity Of 150 Kg , Wart Free Budloo Wooden Ladder 17 Feet Long And Slightly Tappered Upwards The Steps Are To Be Fixed With Flat Galvinized Iron Strip With Galvinized Nails. The Foot Of The Ladder To Be Provided With Rubber Anti Skid Hold. , Wart Free Budloo Wooden Ladder 20 Feet Long And Slightly Tappered Upwards The Steps Are To Be Fixed With Flat Galvinized Iron Strip With Galvinized Nails. The Foot Of The Ladder To Be Provided With Rubber Anti Skid Hold. , Telescopic Ladder 20 Ft Long, 6063 T5 Grade Of Aluminium , 150 Kg Load Capacity, Self Locking Mechanism, Anti-Skid Foot Caps , Hand Held Search Light Led Lamp, 100 Watt With Lithium Ion 3.7 V, 3.5 Ah, 500 Lux/100 Mtr With Lamp Life -50000 Hours, Ip 65, 12 Months Warranty , Hdpe Pipe Outer Dia 180 Mm Inner Dia 152 Mm For Laying Of 11Kv Xlpe Cable From Power Transformer To Control Room , Mccb - 200 Amps,36Ka,4P Adjustable , Mccb - 40 Amps,36Ka,4P Adjustable , Mccb - 63 Amps,36Ka,4P Adjustable , Mccb - 100 Amps,36Ka,4P Adjustable , Mccb - 160 Amps,36Ka,4P Adjustable , Mccb - 250 Amps,36Ka,4P Adjustable , Mccb - 400 Amps,36Ka,4P Adjustable , Mccb - 630 Amps,36Ka,4P Adjustable , Mccb - 200 Amps,36Ka,3P Adjustable , Mccb - 100 Amps,36Ka,3P Adjustable , Mccb - 160 Amps,36Ka,3P Adjustable , Mccb - 250 Amps,36Ka,3P Adjustable , Mccb - 400 Amps,36Ka,3P Adjustable , Mccb - 630 Amps,36Ka,3P Adjustable , Bobin Insulators Clamps/Cliffs. , Epoxy Resin Cast Panel Insulators Upto 500Mm , 18 Feet Fiber Link Rod , 18 Feet Bamboo Link Rod , Al. Solderless Clamps Suitable For Transformer 1000 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 630 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 400/500 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 250 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 100 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer 63 Kva As Per Relevant Is , Aluminium Thimbles 630 Mm2 As Per Relevant Is , Aluminium Thimbles 500 Mm2 As Per Relevant Is , Aluminium Thimbles 400 Mm2 As Per Relevant Is , Aluminium Thimbles 300 Mm2 As Per Relevant Is , Aluminium Thimbles 240 Mm2 As Per Relevant Is , Aluminium Thimbles 185 Mm2 As Per Relevant Is , Aluminium Thimbles 120 Mm2 As Per Relevant Is , Aluminium Thimbles 95 Mm2 As Per Relevant Is , Aluminium Thimbles 70 Mm2 As Per Relevant Is , Aluminium Thimbles 50 Mm2 As Per Relevant Is , Aluminium Thimbles 35 Mm2 As Per Relevant Is , Aluminium Thimbles 25 Mm2 As Per Relevant Is , Aluminium Thimbles 16 Mm2 As Per Relevant Is , Aluminium Thimbles 10 Mm2 As Per Relevant Is , Dpc Copper Winding Wire (Round) In Sizes 11 To 22 Swg Fresh. , Dcp Copper Strip Of Sizes For Lv Winding Of Distribution Transformers 250 Kva To 630 Kva Fresh. , Se Copper Winding Wire (Round) In Sizes 11 To 22 Swg. , Dpc Aluminium Winding Wire (Round) In Sizes From 12 To 20 Swg-Fresh , Dpc Aluminium Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva - Fresh , Se Aluminium Winding Wire (Round) In Sizes 12 To 20 Swg-Fresh , Dpc Copper Winding Wire (Round) In Sizes 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Copper Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Se Copper Winding Wire (Round) In Sizes 11 To 22 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Aluminium Winding Wire (Round) In Sizes From 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Dpc Aluminium Strip Of Sizes For Lv Winding Of Distribution Transformers 25 Kva To 630 Kva ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Se Aluminium Winding Wire (Round) In Sizes 12 To 20 Swg ( In Exchange Of One Kg Of Scrap Of Salvaged Conductor) , Lv Brass Bush Rods 12 Mm , Lv Brass Bush Rods 19 Mm , Lv Brass Bush Rods 25 Mm , Lv Brass Bush Rods 32 Mm , Press Card Board Soft Calendared Solid 1Mm/2Mm/3Mm(As Per Sample) , Press Card Board Pre Compressed Solid 1Mm/2Mm/3Mm. , Ht Insulating Gum , Glass Wool Sleeves Of Sizes , Aluminium Brazing Rod (Standard Length) , Copper Brazing Rod (Standard Length) , Flexible Copper Strip (Shim) 75Mm X 0.5 Mm , Pvc Sheets 1 Mm Thick , Empire Tape 1 , Electrical Grade Kraft Paper, 4 Mil , Leatheroid Insulation Paper 20 Mil. , Hv Bushing , Lv Bushes Suitable For 63 To 100 Kva Dt , Lv Bushes Suitable For 200 To 250 Kva Dt , Lv Bushes Suitable For 400 To 630 Kva Dt , Epoxy Resin Cast 1.1 Kv Low Voltage Transformer Bushing With Busbar For 400/630 Kva Dt , Cotton Tape 1 (Size) 35 M Long. , Rubber Washers , Ht Paper , Cork Washer 12Mm Dia , Cork Washer20mm Dia , Cork Washer 25Mm/30Mm Dia , Plastic Metre Seals , Trifor (Tower Roller) , Transformer Oil Filitration Plant Filter Elements Of 1 Micron(60X250) Mm For Transformer Oil Filitration Plant , Heating Elements Of 2000 Watts For Transformer Oil Filtration Plant , Press Cardboard Cutter Having Bed=52X21 With Height Of Machine 45 With No. Of Tensile Springs 2 Nos. Complete In All Respects. , Angle Grinder, 800W Power, No-Load Speed Of 11000 Rpm, 100 Mm Disc , Welding Machine(Inverter Type) =5=10 Kva Rated Input Power, Maximum Welding Current At 60% Duty Cycle (In A) 150=250, Adjustable Hot Start,Anti-Stick Functions,Arc Force Control , Cordless Impact Drill/Drivers With 2 Batteries, Ideal For Driving Screws Into Wood And Drilling Into Masonry, Metal, And Wood , Pneumatic Air Impact Wrench With Sockets From 15 To 30 , Air Compressor 50 Ltr , Hand Held Brush Cutter , Hydraulic Crimping Tool , Pallet Truck 3 Ton , Hand Driven Insulation Resistance (Meggar) , Multimeter(Analog) , Multimeter(Digital) Voltage: Dc: 1000 Volts; Ac: 1000 Volts; Dc Accuracy: ± 0.5% + 3 Digit; Ac Accuracy: ± 1% + 3 Digit; Current: Dc: 10 Amps; Ac: 10 Amps; Dc Accuracy: ± 1.5% + 3 Digit; Ac Accuracy: ± 1.5% + 3 Digit; Resistance: 40 M Ohm; Resistance Accuracy: ± 1.5% + 3 Digit ; Capacitance: 1000 Μf; Capacitance Accuracy: ± 5% + 5 Digit Cat Iii 600 Volts Safety Rating , Pliers -Type Of Hand Tool-Combination Plier As Per Is 6149, Type Of Insulation-Rubber Insulation, Material-Carbon Steel , Nawara Tape 1 (Size) 35 M Long. , Rubberized Cork Sheet 4 Mm Thick 2Ftx3ft , Rubberized Cork Sheet 3Mm Thick 2Ftx3ft , Bakelite Tubes 12Mm Dia ( 1 Mtr Long) , Hv Bush Clamps (Ms) , Aluminium Clamping Member (Shoes) For Hv Bushing , Lv Cork Washers 12 Mm Dia , Lv Cork Washers 20Mm Dia , Lv Cork Washers 25 Mm/30 Mm Dia , Nuts & Bolts (M.S) Of Sizes. , M.S Flat Washers. , Hv Cork Washers 110 Mm O.D , Aluminium Welding Flux , Aluminium Flat 4/6/8/10 Mm Thick Of Required (Busbar) , Copper Flat 4/6/8/10 Mm Thick Of Required Width. (Busbar) , Ms Plug & Caps 1/2 ; 3/4; /1; 1.1/4; 1.1/2 , Oil Seal Rings (O-Rings) For Lv/Hv Bush Rods 12 Mm Dia. , Oil Seal Rings (O.Rings) For Lv/Hv Bush Rods 20 Mm Dia , Oil Seal Rings (O.Rings) For Lv/Hv Bush Rods 25 Mm Dia , Creep Tape 1 , Cotton Cloth , Empire Sleeves Of Sizes , Synthetic Enamel Paint Smoke Grey Colour , Paint Thinner , Steel Primer , Silica Gel , Transformer Oil As Per Is 335 And Amendments Thereof , Welding Rods 3.15 Mm/4Mm. (100 No. Per Packet) , Refilling Of Oxygen Gas For Brazing , Refilling Of Lpg Gas For Brazing , 12 Piece Tool Kit (1-Piece Screwdriver, 1-Piece Hammer, 7-Pieces Screwdriver Bits, 1-Piece Plier, 1-Piece Wrench(Adjustib And 1-Piece Measuring Tape) Bosch/Dewalt/Taparia , Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [Fluke/Digi Sense/ Motwane/Extech] , 12 Volts, 42 Ah Lead Acid Battery , 12V 7 Ah Rechargeable Sealed Maintenance Free Battery (Smf) For Ups , Battery Connector For 12 V Battery Bank (12 No. Both Ends Of Each Connector Should Be Properly Clamped With Nuts, Bolts, Washers) , Fabricated Gi Pollar Collar 50X6 Mm With Nuts And Bolts , Digital Weighing Scale Upto 1 Ton , Portable Professional Petrol Chainsaw,18 Inch Or Above, 2 Kw Or Above, Pitch Of 3/8 Or Above, Petrol Capacity 400 Ml Or Above. , Double Ply Polyester Webbing Slings, Load Capacity 6 Tonne , Dee Shackles Forged Shackles, Working Load 6.5 Tonne , Eyebolt With Recessed Collar With Maximum Axial Lifting Capacity Of 6 Tonne , Handheld Brush Cutter / Line Trimmer, With Nylon Feed Head Attachment Petrol Engine Low Vibration Centrifugal Clutch, Hardened Steel 2 Teeth Blade, Bump / Tap & Go Type, Shaft Length (Mm) 1425 To 1449, Circular Saw Attachment Inclusive In The Scope Of Supply , Portable Hydraulic Crimping Tool For 30 Sqmm To 400 Sqmm With All Attachments , Pre Fabricate Galvanized Single Way Top Bracket (1000 Mm Long With 48.3 Od Gi Pipe) To Be Fitted On Top Of Octogonal Pole For Holding Lighting Luminaries. , Dk Thermoplastic Cable Junction/ Termination T Boxes 8X10Of Class Ip55/Ip65 Fitted With Two 2-5 annual periodical maintenance Mcb Strip,4-Way Terminal Block / Connectors Incl. Copper Lugs, Clamps ,Nut & Bolts Washers Etc (Hansel Or Equivalent Make) Or Poles With Two Way Type Bracket To Be Fitted Properly Inside The Door Opened Gear Box Provided On Thebottom Side Of The Pole. , Surge Protector For The 120/190 Watt Led Type Lighting Fixture Complete. , Outdoor Type Lt Control Panel Size 900Mmx900mmx450mm Having Input Main Control Of 100 annual periodical maintenance Mccb With Tpn Bus Bar With 40 annual periodical maintenance Tpn Mcb 4Nos For Outgoing Circuits,Including Astronomical Switching With Contactor Of Required Capacity. The Panel Should Be Fitted With A Digital Composite Voltmeter/Ampermeter/Indicator Set With Selecter Switch And Backup Protection System, Thimbling And The Panel Shall Further Be Provided With Proper Openings On Front Side As Well As On Rear Side Including Its Locking Arrangement And Also With Required Glands And 4No. Angle Iron Legs For Grouting The Panel On Bed , The Panel Shall Also Be Provided With Powder Coat/Pu Paint. The Item Includes Its Thimble As Required At Taping Point For Incomming , Out Going And Internal Panel Wiring Complete Unit. , Dust/Rain/Snow-Proof Canopy Type Mini-Outdoor Lt Feeder Panel Of Size 450X300mm With Front Door Opening Duly Powdered Colour Coated With Inbuilt 2No Tpn 16-32 annual periodical maintenance Mccb,Tpn Busbars Of Same Capacity Installed On Cement Concrete Block With 4 Angle Iron Legs Grouted In The Cement Concrete Of Termination Of Main 25Sqmm Cable And Outgoing 25/16 Sqmm Cable Circuits. , 120 Watt Led Luminaries Of Ip 67 Protection. , 190 Watt Led Luminaries Of Ip 67 Protection. , 110 W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 70W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 50 W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 30W Led Light Fitting With /= 100 Lm/Watt Efficacy Ip 67 Ingress Protection (Ip Rating) As Per Is:10322 (Part 1):1982 Latest, 90 To 300 Volts Ac At 50 Hz+/-2 Input Voltage Range, 230 V Ac 50 Hz Rated Voltage, Poly Carbonate Lense, Smd Led Chip As Per Lm 80/Is16106, Ip 66 Protection Of The Entire Housing (Both Led Section And Driver Section) As Per Is:10322 (Part 1):1982 Latest , 6 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 1Pole With 1Pp, 240 V , 10 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range B, 1Pole With 1Pp, 240 V , 10 A Dp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2 Pole With 2 Pp, 240 V , 16 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 1Pole With 1Pp, 240 V , 16 A Spn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2Pole With 1Pp, 415 V , 16 A Tp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 3Pole With 3Pp, 415 V , 32 A Tpn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 4 Pole With 3 Pp, 415 V , 32 A Tp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 3 Pole With 3 Pp, 415 V , 32 A Dp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 2 Pole With 2 Pp, 415 V , 32 A Sp Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range B, 1 Pole With 1 Pp, 415 V , 63 A Tpn Mcb, 10 Ka Rated Short Circuit Capacity (Ampere), Instantaneous Tripping Range C, 4 Pole With 3 Pp, 415 V , Astronomical Timer For Street Light Control, 3 Phase, 18 Kw/43 A Each Phase, Ip 66, Manually Settable Timer With 12 Programmes Spreaded Over A Year As Defined Programme, 260 Volt +/- 5 Volt Over Voltage Protection Per Phase, 160 Volt +/- 5 Volt Under Voltage Protection Per Phase, Operating Temperature Range -10 To +50 Deg C, /=60 Seconds On/Off Timing Accuracy , Embossing Punch Die Tool For Dt Coding (A-Z And 0-9) , Battery Operated Engraving Machine , Hand Operated Oil Pump/Barrel Pump , Manilla Rope - 25 Mm , Nylon Rope- 20 Mm , 11Kv Pilfer Resistant Metering Cubicle For 3Phase 4 Wire Metering System Made Of Ms Sheet Steel Thickness Not Less Than 2Mm Duly Power Coat Painted Suitable For Indoor As Well As Outdoor As Per The Site Requirement. The Cubicle Shall Be Painted Through 7-Tank Process. The External Dimensions Should Be Adequate. Panel Having Two Compartments Upper Meter Compartment And Lower Ct/Pt Compartment. Provided With Synthetic Or Semi Synthetic Gasket Firmly Glued To The Sufrace, Dust, Weather And Vermin Proof And Shall Comply Degree Of Protection Ip 65 Both The Chambers Having One Sided Hinged Door Arrangments. The Metering Panel Shall Be Provided With Two No Ms Channels Of Size 100 X 50 Mm On The Front And Rear Sides Duly Welded And 4 No Of Lifting Hooks. It Should Be Possible To Take Meter Reading Manually, Through Cmri And Computer Without Opening The Lv Chamber Door. , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 2.5 /5 For 25Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 5/5 For 63Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 7.5/5 For 100Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 15/5 For 200Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 20/5 For 250Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 25/5 For 400 Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 50/5 For 630 Kva Dt , Single Phase, Single Core, Single Ratio, Epoxy Resin Cast Current Transformers Suitable For 11Kv, Copper Wound Primary Type With Rated Burden 5Va And Accuracy Class 0.5 Or Better And Conforming To Is2705 (Part-I & Ii) Amended Upto Date. Isf Shall Be Upto 5The Ct Ratio Shall Be 75/5 For 1 Mva Dt , 11Kv/ 110 V, Three Phase Epoxy Resin Cast Pt With Rated Burden 15Va Per Phase And Accuracy Class 0.5 Or Better And Conforming To Is:3156 (Part-I&Ii) Amended Upto Date With Proper Colour Coded Identification. Pts Shall Be Of Uniform Insulating And Withstand Separate Source 23Kv providing fixing For One Minute. , 3Ph, 3 Wire Ht Ct/Pt Operated Fully Static Smart Tri-Vector Energymeters Dlms Compliantcategory C With Rs232 Port For Modem Compatibility. 11Kv/110V, Ph-Ph (3P,3W) Metersfor Measurement Of Different Electrical Parameters Including Active Energy (Kwh/ Mwh), Reactive Energy (Kvarh/Mvarh), Apparent Energy (Kvah/ Mvah) Etc. (Make L&T, Secure,Abb) , Led String Light 15 Mtr Long Of Different Colours (Saffron/White/Green) With Controller. , 4 Socket Extension Boards With Each Compatible Sockets Of 16 annual periodical maintenance And 5 Mtr Long Cable And Plug Along Surge Protector And On/Off Controller.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Jammu And Kashmir View Result →
11.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
12.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
13.
Communications and Information Technology  #10826870 Price Bid
Operation & Comprehensive Maintenance of Electromechanical Services For TE MAX-I Dhule. (Revised)., comprehensive maintenance and round the clock operation of various electromechanical services as per details given in relevant sections by deploying the required staff including specialized manpower and by arranging required tools and plant etc to keep all the services operational upto the required standards . ( except item 2 & 3 ) , a ) services included are , 1 ) ei & fans , 2 ) compound lighting , 3 ) lightning conductor , 4 ) pumps , 5 ) 2x400 ( 11 kv ) i/d substation , 6 ) 1 x 100 kva and 1 x 250 kva e/a sets , 7 ) fire detection and alarm system , 8 ) package type a c plants , 9 ) fire extinguishers , contractors to take all steps to undertake preventive / special maintenance and testing to keep the system at optimum working condition . size of various services is given in section - i , size of various services is given in section - i , servicing & routine maintenance ( b check ) of following capacity of dg set complete with cleaning of air cleaner element , replacement of engine lube oil of proper grade ( seal pack of reputed make ) , replacement of lube oil filter elements , replacement of fuel filter elements , check & reset injector pressure , check & reset injector pump timing , retighten cylinder head nuts , adjust engine valve clearance , replacement of radiator water by fresh distilled water with addition of coolant additive concentrate , cleaning of radiator fins , drain sediments from water separator , check inlet air restriction , check air piping , belt tensions i/c cleaning & dedusting of alternator , control panel , fuel tank , tightening & maintaining of all hose connections , electrical connections , battery connections etc & actual load testing of dg set after servicing etc as directed . , a ) 250 kva dg set , b ) 100 kva dg set , supplying & fixing of fully charged 12 volt , 180ah lead acid maintenance free battery for starting of 250 kva dg set complete with end sockets etc note- 1 ) the battery ( s ) of each dg set shall be replaced once during currency of contract & agency shall consider rebate for old battery while quoting of rates ) , supplying & fixing of fully charged 12 volt , 130ah lead acid maintenance free battery for starting of 100 kva dg set complete with end sockets etc note- 1 ) the battery ( s ) of each dg set shall be replaced once during currency of contract & agency shall consider rebate for old battery while quoting of rates )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
14.
Communications and Information Technology  #10826866 Price Bid
Operation & Comprehensive Maintenance Of Electromechanical Services For Te Bldg. & Staff Quarters At Kalatalao Kalyan. ( Revised ) , Comprehensive Maintenance And Round The Clock Operation Of Various Electromechanical Services As Per Details Given In Relevant Sections By Deploying The Required Staff Including Specialized Manpower And By Arranging Required Tools And Plant Etc To Keep All The Services Operational Upto The Required Standards Except Item Nos . 2 & 3 Below Which Shall Be Paid Extra As Per Running Hours Of Dg Sets . A ) Services Included Are : 1 ) Ei & Fans 2 ) Compound Lighting 3 ) Lightning Conductor 4 ) Pumps 5 ) 2 X 750 Kva ( 22 Kv Indoor ) Substation 6 ) 2 X 500 Kva & 1 X 750 Kva E / A Sets 7 ) Fire Detection And Alarm System 8 ) 4 X 7 Tr , 2 X 10 Tr , 3 X 5 Tr Package Type A C Plant 9 ) Split Ac Units / Air Curtain 10 ) 4 X 7 Tr Hpac Unit Plant 11 ) Fire Extinguishers Contractors To Take All Steps To Undertake Preventive / Special Maintenance And Testing To Keep The System At Optimum Working Condition . Size Of Various Services Is Given In Section - I , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I / C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . , I ) 1 X 750 Kva Dg Set , Ii ) 2 X 500 Kva Dg Sets , Supplying & Fixing Of Fully Charged 12 Volt , 180Ah Lead Acid Maintenance Free Battery For Starting Of 750 & 500 Kva E / A Sets Complete With End Sockets Etc . Note- 1 ) The Battery ( S ) Of Each Dg Set Shall Be Replaced ( Measurable Basis ) Once During Currency Of Contract & Agency Shall Consider Rebate For Old Battery While Quoting Of Rates . Additional Requirement To Be Borned By Agency Without Extra Cost .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
15.
Defence #10801071 Price Bid
Tender For Comprehensive B R And Em Repair Maintenance Works To 14 Asc Af Kakkanad Under Age I R D Kochi; 1 Hacking out old broken glass panes 4 mm thick from steel frame including putty/ metal beadings and supply and fix sheet glass ordinary 4 mm thick, in squares n.exc. 0.50 Sqm in each pane including necessary new oil putty or with existing metal beadings complete all as specified and as directed 2 Hacking out old broken glass panes 4 mm thick from wooden framed shutters including putty/wooden beadings and supply and fix sheet glass ordinary quality, 4 mm thick, in square n.exc. 0.5 Sqm in each pane including necessary oil putty/wooden beads complete all as specified and as directed. 3 S&F in repairs extruded aluminium anodised 150 mm long handles fabricated type. 4 All as per item No 3 above but 100 mm long. 5 Supply and fix in repairs foot operated door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring and cover plate overall length 150 mm including taking down defective foot operated door stopper all as specified and as directed. 6 S&F in repairsmortice lock brass 4 levers vertical type 100 mm 7 S & Fin repairs door closer hydraulically regulated, castiron body, designation No -3, universal type ,suitable for door shuttersof 851 to1000 mm in width and of wt between 61 to 80 Kg and fixed 8 Re securing and easing to wooden shutters of any description area n.exc 1 Sqm each without taking down the shutter all as specified and as directed. 9 Re securing and easing to wooden shutters of any description exc 1 Sqmbut n.exc 2 Sqm each without taking down the shutters all as specified and as directed. 10 S&F In repairs Aluminium anodised, barrel tower bolts of extruded section 150 mm long. 11 All as per item No 10 above but 100 mm long. 12 S&F in repairs Aluminium alloy, anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy, 300 mm long 13 Taking down shutters exc 1 sq. m and n exc2 sq. m each and re-fixing in same openings. 14 Taking down shutters n exc 1 sq. m each and re-fixing in same openings. 15 S&F in repairs Butt hinges, medium weight cold rolled mild steel 100 mm size. 16 All as per item No 15 above but 75 mm size. 17 Taking down and removing to or from store chowkats or framesexc 1.5 sq. m and not exc 4 sqm each but with shutters (without taking off shutters from the frames) 18 S&F Solid PVC door frame of size 50mm x 47mm made of of 5mm plain color PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing. 19 S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain color PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color PVC sheets for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain color PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. 20 S&F Aluminium, anodised, barrel tower boltsof extruded section and fixed length of bolt in 200 mm complete all as specified and directed. 21 S&F Butt hinges, medium weight, cold rolled mild steel, and fixed size of hinges in 100 mm complete all as specified and directed. 22 S&F Aluminium handles, cast type, anodised size of handle in 150mm 23 Supply and fix in repair PVC low level flushing cistern 10 liters capacity with ISI mark including inlet, ball valve, float, handle and brackets etc. including taking down old defective low level flushing cistern all as specified and as directed. 24 Supply and fix plastic seat and cover superior quality closed pattern with flat bottom of heavy duty including necessary hinged devices, including taking down damaged/ broken plastic seat and cover from EWC all as specified and as directed. 25 Supply and Fix in repair PVC connection with PTMT nuts of length 450 mm screwed for iron pipe15 mm bore. 26 Supply and fix in repair 15 mm dia CP pillar cocks fancy type for wash hand basin including taking down existing pillar cock, all as specified and as directed. 27 Supply and fix 150 mm square grating of PTMT to floor trap/nahani trap including taking down existing damaged CI grating from floor tap/nahani trap all as specified and as directed. 28 Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 15mm bore pipe, all as specified and as directed. 29 All as per item No 28 above but 20mm bore. 30 All as per item No 28 above but 25/32 mm bore. 31 Supply and fix Unplasticised PVC pipes of bore 15mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 32 Supply and fix Unplasticised PVC pipes of bore 20mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 33 Supplying and laying of CPVC pipes 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 34 S&F in repairs bib taps 15mm bore, cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed for iron pipe or for brass ferrule all as specified and as directed 35 S&F in repairs stop valves 15mm bore, cast copper alloy chromium plated fancy type, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed. 36 S&F in repairs vitreous china wash basin white flat back, size 580x450mm excluding taps waste, chain and plug and porcelain stopper including brackets all as specified and as directed. 37 S&F in repairs vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe). 38 Supply and fix tubular towel rail aluminium anodised20 mm dia D type 60 cm long between flanges including taking down defective aluminium tubular towel rail all as specified and as directed. 39 Supply and fix in repair beveled edgedmirror of size 600 x 450 mm selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. 40 S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls 75 mm bore. 41 All as per item 40 above but 110 mm bore 42 S&F PVC (SWR) bends any radius 75 mm bore 43 Supply and fix in repairs 100 mm dia CIfloor trap/nahani trap including taking down existing damaged CI grating from floor trap/nahani trap 44 M&L Dismantling water tanks and removing to store exc 250 & n exc 500 capacity 45 M&L Dismantling water tanks and removing to store exc 500 & n exc 1000 capacity 46 M&L Rotational moulded polyethylene water storage tanks 500 litres capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia PTMT Ball valve high pressure all as directed. 47 Allas per item No 46 above but 1000 ltr capacity 48 M & L for PU injection grouting by making necessary holes of 8 to 10 mm in concrete to a depth of about 75mm using proper electric hammer drill. Fix new nipples of 8 to 10mm using aluminum pipes using neat cement or M-Seal for proper anchorage. Carry-out pressure grouting using shaligrout 2k /equivalent) using a proper grouting pump. Seal the holes properly after the grouting nipples have been removed all as specified and directed by Engg -In Charge. 49 Material and labour for taking down old plaster and rendering 10mm thick in CM 1:6 on other than fair faces of brickor concrete surfaces finishing smooth and even and smooth without using extra cement making good match the old surface finish. 50 M&L two coat of OBD over a coat of primer on newly plastered surfaces of wall including cornices and preparation of surfaces. 51 M&L pre laminated particle board 12mm thick interior grade pre laminated one side with decorative choice lamination and other side balancing white lamination fixture with screws to frame work 52 Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge 53 M&L Screed bed or bedding layer 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge 54 M&L Rendering 10 mm thick in CM 1:3 on brick or concrete surfaces, finished fair and even for receiving wall tiles. 55 S&F glazed ceramic coloured tiles 300 x 200 x 7 mm thickon vertical surfaces, set and jointed in neat cement slurry and pointed in white/colour cement to match over 10 mm thick rendering (backing coat)in cm 1:3, complete all as specified and directed by Engineer-in-Charge. 56 M & L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm In floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge 57 S&F Vitrified ceramic coloured tiles 10mm thick (Square/ Rectangular) polished area of each tile not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match 58 S&F in repairs health faucet 15mm size chromium plated standard size all as specified and directed. 59 Supply and fixed in repairs stainless steel wire cloth, 0.63mm nominal dia of wire and average width aperture 1.40mm and fixed with tinned tacks, or galvanized wire staples 60 M&L for chip and remove all damaged and de bonded concrete and plaster from the RCC slabs by manually or mechanically so as to expose the corroded reinforcement bars, removingthe debris with in a lead of 100 meters as directed by Engineer-in-charge. 61 M&L for supply and application of Nitobond EP (Manufactured by M/s Fosroc chemicals India Ltd) epoxy bonding agent over the old concrete surface complete all as specified and all as directed by Engineer-in-charge. 62 M&L for supply and application of rust remover/converter (Rebaklense RR of M/s Fosroc Chemicals India Ltd. or equivalent) or Amandur ,(manufactured by GK technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after application complete all as directed by Engineer-in-charge. 63 M&L for plastering with Nitobond SBR (Styrene butadiene polymer bonding agent cum cement mortar/concrete modifier Manufactured by M/s Fosroc Chemicals India Ltd or equivalent) modified cement mortar (1:4) under the slab to an average thickness of 40 mm (applied in two layers not exceeding 20mm each) , including the cost of all materials rent of tools and labour charges etc complete all as directed by Engr-in-charge. 64 M&L Preparation of newsurfaces of ceiling and applying two coats of distemper oil emulsion on ceiling over a coat of primer over 3 mm thick wall care putty plastered and other surfaces with alkali resistant priming paint complete all as specified. 65 Taking down cement plaster of any description on walls incl raking out joints, hacking for key scrubbing down with water 66 M&L for plastering in CM1:6, 10 mm thick on interior walls finished even and smooth w/o using extra cement. 67 M&L for plasteringin CM 1:3, 5mm thick on ceiling finished even and smooth w/o using extra cement 68 M&L for two coats of Antifungal paint (Apex ultima Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Professional pack of Asian paints) over a coat of external wall care putty n.exc 2 mm thick on new or old prepared plastered external surfaces . 69 M&L Preparation of Newsurfaces of internal walland applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 70 M&L Preparation of oldsurfaces of internal wall by complete removal of existing treatment , and applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 71 M&L Preparation of old surfaces of ceiling by complete removal of existing treatment, and applying two coats of distemper oil emulsion on ceiling over a coat of primer, plastered and other surfaces with alkali resistant paint complete all as specified. 72 Demolition of brick work / PCC block masonry work built in cement mortar etc complete all as specified. 73 M&L Precast Concrete block masonry with solid blocks in PCC 1:3:6 type C1 (using 20 mm stone agg) exc 10 cm in width and setting in mortar 1:4with minimum compressive strength of 5N/ sq mm complete all as specified and as directed. 74 M&L for providing and fixing Gypsum Board 12mm thick in walls fixed with screw as per manufacturer’s instructions complete all as specified. 75 Dismantling in Wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified. 76 M & L Anodised aluminium snap grid frame work (size of grid 605x 605) mm for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified and as directed. 77 M&L for providing and fixing Exposed metal frame ceiling with fire resistant calcium silicate board of siliceous and calcareous material reinforced with cellulose fiber for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) fixed with screw as per manufacturer’s instructions complete all as specified. 78 Cleaning (mechanically)of sewage line/effluent drains 150/110 mm dia and disposing offthe sludge outside MoD land complete all as directed. 79 Removing the chokes in drains of WC/bath room/kitchen up to 1st manhole including cleaning of gully traps in single storey/ground floor of multi storeyed buildings, all as specified and directed. 80 Removing chokes in drains of WC/bath room/kitchen other than ground floor all as specified and directed. 81 Destruction of growth of weed plants with roots level on wall/ roof of building any height with weedicides such as Round up manufactured by Excel Chemical Industries and sprayed in and around roots and the place of possible growth of weeds as per manufacturer’sinstructions and making good the surfacescomplete all as specifiedand as directed. 82 Demolition of reinforced cement concrete in any position not otherwise specifically provided for 83 M& L for Precast RCC Cover slabs type B-1, 1:2:4 (20 mm graded stone aggregate as in slabs of drains including necessary form works. (Reinforcement bar will be measuredand paid separately). 84 M&L TMT bars 10mm dia and over cut to length bent to shape required, including, cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed ) not less than 0.9mm dia or securing with clips 85 Demolition of cement concrete in any position not otherwise specifically provided for complete all as specified and directed. 86 M & L for 1:3:6 Type C-2 (using 40 mm graded stone aggregate) for surface channels anddrains all as specified 87 Extra for forming fair finished drain or channel 30 Cminner girth in cement concrete ,using extra cement, including forms, moulds, mitered /stopped endsetc 88 Opening manhole of septic tank remove night soil and sediments including liquid by mechanical pumping into tanker lorry having cleaning internal surface with water and re-fix the manhole covers, complete all as specified and directed. Notes :-(i)Volume of the manhole will be worked out based on the depth or actual depth of sludge, whichever is less.(ii) Water shall be procured by the contractor for cleaning purpose. 89 Demolition of cement concretein ground floors and pavings n.exc 15 cm thickness (below or above ground level) 90 M&L for 100mm thick PCC ( 1:3:6)type C-2,using 40mm graded stone aggregate as in hard standing/path/sub basefinished to an even and fair surfaces. 91 M&L forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade A. 92 Dismantling structural steel work incl doors, gates but excluding framed trusses. 93 S & FMS work in railings, balusters, posts and struts in fencing etc including cutting tops to shapeas directed, includingall necessary welding, drilling bolting or riveting etc and similar work conforming to FE 290 Gd E-165 complete all as specified 94 S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc. complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging with and including hooks and hinges, also fastening and fixing complete conforming to Fe-410W (Gde-E-250) 95 M&L for Point wiring for light point /fan point/Exhaust fan /Bell Pointwith 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate and cover with GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. including dismantling /removing of burnt cable/making good surface asrequired . 96 M&L for submain wiring for 5 Amp socket outlet point on independent board with 2x 1.5 sqmm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with multi standard copper conductors and earth continuity wire with similar 1x1.5 sqmm cable (incl connecting to earth dolly) drawn through and single core cable in surface/recessed medium class PVC conduit including dismantling /removing of burnt cable/making good surface as persiterequirement . 97 Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch and 5/6A modular socket ,connection etc. as required atsitecomplete all as specified and directed (for Independent 5 Amp socket ) . 98 M&L for wiring for circuit along with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit as required .wire 2x22.5 sq.mm + 1x2.5 sq.mm earth wire for 15/25 power plug/socket. 99 All as per item above but Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 A modular switch and 15/16A modularsocket ,connection etc. as required atsitecomplete all as specified and directed( for 15/16 Amp Socket ). 100 M&L for wiring for circuit along with 4 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface /recessed steel conduit as required .wire 2x4 sq.mm + 1x4 sq.mm earth wire (for Ac & Geyser ) 101 S&F Electronic ceiling fan regulator, modular type stepped /socket type heavy duty suitable to work on 230 volts complete all as specified and directed. 102 Supply & Fixing piano type 5/6 amps switch on the existing Switch box including connection as required on site. 103 Supply & Fixing piano type 2 way 5/6 amps switch on the existing Switch box including connection as required on site. 104 Supply & Fixing piano type 15/16 amps switch on the existing Switch box including connection as required on site. 105 Supply & Fixing piano type 3 pin 5/6 amps socket outlet switch on the existing Switch box including connection as required on site. 106 Supply & Fixing piano type 6 pin 15/16 amps socket outlet switch on the existing Switch box including connection as required on site. 107 Supply & Fixing 5/6 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 108 Supply & Fixing 15/25 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 109 Supply & Fixing 3 pin 5/6 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 110 Supply & Fixing 6 pin 15/25 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 111 Supply & Fixing modular bell push on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 112 Supply and fixing 1 or 2 module base & cover plate on existing modular metal boxes etc as required. 113 Supply and fixing 3 module base & cover plate on existing modular metal boxes etc as required. 114 Supply and fixing 4 module base & cover plate on existing modular metal boxes etc as required. 115 Supply and fixing 6 module base & cover plate on existing modular metal boxes etc as required. 116 Supply and fixing 8 module base & cover plate on existing modular metal boxes etc as required. 117 Supply and fixing LED light fitting 1X20W,220V high efficiency(efficiency up to 100lm/w) polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-20-30/40/65-SL-DP-NWHor GM/ Panasonic/Havells etc. 118 Supply and fixing LED light fitting 1X10W,220V high efficiency(efficiency up to 100lm/w)polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-10-30/40/65-SL-DP-NWH or Havells /Panasonic/GM etc. 119 S & F in repairs LED 20W T8 Tube within built driver and efficiency of 100lm/w having glare free lighting distribution, double sided connection, housing made of high grade polycarbonate cover, 2.5 KV internal surge protection, IP20 ingress protection, PCB mounted on extruded metal plate. Make: Crompton model No LT8-20-865-(2) or equivalent in Havells/C&S/ Phillips/Bajaj. 120 S&F switch socket combination 5 Amp with PVC box suitable for 230 Volt on surface. 121 S&F switch socket combination 15 Amp with PVC box suitable for 230 Volt in surface 122 M&L switch socket combination2 in 1, 6/16 Amp flush type in existing switch box. 123 All as per item above but 6 Amp flush type in existing switch box. 124 M&L forbell AC 230 V Single pole ding dong type. 125 Supply and fixing angular type batten holder insulator body of PVC/ polycarbonate type suitable for 10/9 W Led bulb. 126 Supply and fixing fan condenser / capacitor of size 2.25/2.5 suitable for ceiling fan of any sweep. 127 Supply and fixingonly LED lamp of 9 watt, Make : Crompton/ Havells /Panasonic 128 S&F of 20 Amps 240 V , SPN Industrial type socket outlet, with 2 pole and earth ,metal enclosed plug top along with 20 A C Curve ,SP MCB , in sheet steel enclosure ,on surface or in recess with chained metal cover for the socket outlet and complete with connections ,testing and commissioning etc. as required . 129 Supplying and fixing 6 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 130 Supplying and fixing 8 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB / RCCB/Isolator) 131 Supplying and fixing 4 way, Horizontal type , Three pole and neutral Dl sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator) 132 Supply and fixing of 5A to 32 A rating, 240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole in the existing MCB DB Complete with connections, testing and commissioning etc ax required. 133 Supply and fixing of 5A to 32 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc ax required. 134 Supply and fixing of 63 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of Triplepole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc as required. Make: IndoAsain, HSN Code: 8536, Cat. Nos.: 810107 or equivalent make of LT/ Havells. 135 M & L LED Square surface mounted Led Panel 12w, PDC housing and high translucent frosted plastic diffuser makes it a robust Luminar and efficiency up to 100lm/w. Make: Crompton, Model no LCDSPLN-R-12-CDL or equivalent make of GM/Havells. 136 M & L LED Round and Square recess mounted 12w LED edge lit slim down light with die cast aluminium housing finished in premium white coating and efficacy up to 100lm/w suitable for false ceiling. Make Crompton, Model no LSCRM-12W-WW/NW/ CDL or equivalent make of GM/Havells. 137 Dismantling and taking down ceiling fan any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re fixing the same in position, connecting and testingall as specified and directed. 138 M & L for carry out rewinding of ceiling fan motor of any size/ make including taking down from any height ,dismantling ceiling fan motor , removing old burnt winding wire, cleaning the armature thoroughly and replacing the same with new enameled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling and removing the old painting and providing newpainting to ceiling fanscompletewith synthetic enamel Grey paintby spraying using machine including filling cavities with filler one coat after cleaning all dust making the surface in good finishes etc , testing, re-fixing the same in original position complete all as specified and as directed by the Engineer - in - Charge.Note: Rate include the taking down the ceiling fan and deposited to MES store for checkingand repairing) 139 All as per Item above but for the Exhaust fan of 300 /450 mm sweep sizes: 140 S & F in repairs of LED 36W surface full lit luminaire with glare free uniform illumination with longer life and less maintenance available in 2x2 ft (> 100 lm/w).Make: Crompton, Model No LCTLSNE-36-FO-WW/TL/CDL or Havells /C&S/ Phillips/Bajaj. 141 Supply andLayingGI tubing medium grade of size 50 mm with and including all fittings such as bends, elbows, tees, short pieces etc complete in trenches of following sizes after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. Note- Excavation & earth work will be measured & paid separately. 142 All as per item above but 40 mm bore 143 All as per item above but 25 mm bore 144 Supply & Fixing of Size 50 mm GI tubing medium grade withand including all fittings such as bends, elbows, tees, short pieces etc complete on wall and ceiling or laid in floors after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. 145 All as per item No 4 above but 40 mm bore 146 All as per item No 4 above but 25 mm bore 147 All as per item No 4 above but 20 mm bore 148 Repairs to leakage /damaged G.I. pipe of size 50/40 mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples ,Bends etc. all asdirected by Engr- in- charge. Note:- G.I. pipe length will be measured and paid separately under relevant item of sch A 149 All as per item above but 25/20 mm bore 150 Supply and fix in repairs gun metal gate valve of size 50 mm ISI marked with iron wheel head screwed both ends all as directed. 151 All as per item above but 40 mm bore 152 All as per item above but 25 mm bore 153 All as per item above but 20 mm bore 154 All as per item above but 15 mm bore 155 S&F in repairs un plasticized PVC pipe, 25mm bore of pressure rating 10 Kg/ Sqcm with all fittings, fixed to walls, ceilings or in floors complete with snap clips hooks etc and taking out old unserviceable one all as specified an as directed 156 All as per item above butof size 20 mm bore dia 157 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil forlaying/taking out GI pipe line all as specified and directed. 158 Returning filling in including spreadingleveling watering and well rammingin layer not exceeding 25 cm in soft/loose soil all as specified and directed. 159 Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mabove the starting point all as specified and directed. 160 M & L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside of the RCC Under Ground Sump of10,000 Ltrscapacity by dewatering the sump and cleaning the complete inner surfaces by rubbing / scrapping by wire brush to removethe sludge, washing with bleaching powder solution and then with water and draining out sludge, water completely including applying one coat of white wash to all the inner surfaces, and details of tanks like date of cleaning ,capacity of tanks etc shall be written on the outside of the tank with synthetic enamel paint with lettersize 20 cm high in white color , over a black backgroundof size 100x60 cmand charges included for pump set for de watering incl operator all as specified anddirected 161 M&L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside PVC Service tanks kept on roof top of buildings or on stagings, cleaning the surface using brush and other cleaning materials such as bleaching powder as required including writing the capacity of the tank and date of cleaning with white enamel paint over black back ground all as specified and directed for the following capacity of tanks at different locations on Technical/Residential Buildings all as specified and directed by Engr-in-Charge. 162 2000 Ltr capacity 163 1000 Ltr Capacity 164 500/300 Ltr capacity 165 S&F in repairs float Valve 40mm bore (Ball brass valves) high pressure type with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed and taking out old unserviceable one all as specified and directed 166 All as per item above but of size 25mm bore 167 All as per item above but of size 20mm bore 168 S&F in repair/replacement HDPE Tank cover suitable for 300 to 1000 Litr capacity and taking out old unserviceable one 169 All as per item above but for 2000Ltr capacity tanks 170 M&L for repair/replacement ofFoot valve of size 50mmbrass heavy duty including taking up the suction pipe and re-fixing the same after replacement of foot valve in to the sump for proper functioning of pump and taking out old unserviceable one all as specified and directed 171 Dismantling of Mono-block Pump set from the existing position for servicing including opening the pump replacing the unserviceable ball bearings of suitable size for capacities up to 5 HP including greasing complete all as specified and directed 172 Repairs and servicing of Electric chlorine dozing Pump/ system Make Sathya sai Aqua Pura Services with Ant siphon valve including servicing of pump and motor with repair/ replacement of unserviceable parts like piston, stroke controller, suction and delivery tubing, PVC foot valve, nozzle, solution tank inlet, PVC water tubing 15mmbore, gate valve 15mm size etc, complete all as specified and directed. 173 M&L for cleaning of pump sets starter panel after dismantling the incoming and outgoing connections from MCCBs /MCBs and replacing the old unserviceable gland, lugs, nuts &bolts, push buttons, indicating lamps, supporting insulators etc, and checking the serviceability of MCBs cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed 174 M&L for Replacement of unserviceable DOL Starter suitable for motor up to 5 HPincluding connections 175 M&L for Repairing the old Valve pit of dimension 60x45x45 cm by taking out plaster and rendering with 10mm thick CM(1:4) including PCC (1:3:6) TYPE C2 on base, brick work inCM (1:4) as required and applying two coats of white wash on plastered surface including applying two coats of synthetic enamel paint over one coat of red oxide primer over steel surfaces after preparation, complete all as specified and directed 176 M&L for painting pump set including preparation old surfaces and painting with two coats of synthetic enamel paint over a coat of red oxide primer including marking the signs, letters, Nos on the pump setof capacity up to 2HP all as specified and as directed. 177 M&L for painting of old painted GI pipe of any size on the external surfaces after preparation, located in and out of Pump House, by scrapping and cleaning of external surfaces and applying two coats of Sky Blue paint over a coat of red oxide primer complete all as specified and directed. 178 Dismantling , taking out complete burnt winding wire of submersible motor including cleaning of statorslots replacement of defective parts and rewinding with existing type & gauge ofcopper wireas per motor capacity and using new insulation material such as insulating paper sleeves etc. replacement of submersible cable as required length complete all as directed of rating 1.5/2HP Single phase 179 Repairs to leakage /damaged G.I. pipe of size 80 to 100mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples, Bends etc. all asdirected by Engr- in- charge. Note:- (i) G.I. pipe length will be measured and paid separately under relevant item of sch A 180 Material Labour for fixing Mechanical joint suitable 80 mm dia GI pipe, fabricated and made out of MS sheet of thickness 6/8 mm including welding work, rubber gasket, nuts, bolts and washers complete all as specified and directed by Engr in charge. 181 Comprehensive Maintenance, Servicing and carrying out periodical service to DG set along with AMF panel or standard panel like carry out oil service and routine checkup/maintenance as per manufacturers schedule, checking complete system of lubrication, cooling systems, air intake systems, fuel systems, exhaust systems, DC/AC electrical systems in DG Set as well as in AMF/Standard Panel, tightening bolts and nuts in engine and alternator related systems, etc and repairs including material for renewal/ replacement of minor defective parts of like connectors, MCBs , phase indication lamps etc for following capacity of DG sets all as specified and directed by Engr in charge. 182 35 KVA with AMF Panel installed at 14 ASC, AF Kakkanad 183 20 KVA with AMF Panel installed at 14 ASC 184 Note:The spares to DG Sets items as listed below as SUPPLY ONLY will be used whenever required only and it shall measured and paid separately under respective items. 185 The rate is inclusive of all items as required at site except those items as SUPPLY ONLY below to keep the DG Set along with AMF / Standard panel on monthly basis complete all as specified and as directed by Engr-in-Charge. 186 The contractor should attend any complaint / breakdown immediately on call basis and even no. of times without any extra cost. 187 Contractor should submit the inspection / maintenance report of every visit in spite of no of visits during breakdown calls including mentioning the status of DG Sets and spares any replaced 188 The old unserviceable spares replaced under comprehensive maintenance i.e. in sl No 02 of above BOQ is the property of contractor for which credit shall be deducted under respective items in schedule of credit. 189 All AMF panels and standard DG set panels should be well cleaned with CTC solution checking all the electrical connection and tighten for any loose connection. 190 Supply and replace of heavy duty diesel engine oil of 20W40 grade for DG Sets having capacities varying from 15 KVA to 35 KVA complete all as specified and as directed. 191 Supply only Lub Oil Filter for DG set 15 KVA to 35 KVA 192 Supply only fuel filter forDG set 15 KVA to 35 KVA 193 Supply only Oil pressure gauge for DG set of any size/make 194 Recharging of Battery 12 Volts , up to180 AH any make / type by replacing electrolyte including replacement of unserviceable terminal posts , to the required standard complete all as specified andas directed . 195 Diesel hose of size 5/16 all as directed 196 Battery terminals one end socket and the other end clamp type including brazing work and applying jelly over the battery terminal and pole all as directed by the Engr in charge 197 Water hoses complete set of engineDG sets of cap 15 to 35 KVA 198 Repairs to 12 V self starter of DG set engine by dismantling, removing and replacing the old defective/worn-out bearings, servicing including replacement of carbon brush, bendix drive, cleaning commutator in armature etc assembling and testing for satisfactory function all as directed. 199 Supply only auxiliary contactor suitable for AMF panel of 15 to 35 KVA DG set 200 Supply only power contactor suitable for AMF Panel of 15 to 35 KVA DG set 201 Supply, install, testing & commissioning in repairs DC relay card/ PLA relay 12/24 volt DC for DG set any capacity including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed by Engr-in Charge, 202 Supply and mixing water coolant in radiator water of DG Sets having capacities varying from 15 KVA to 320 KVA complete all as specified and as directed. 203 Repairs to door of acoustic enclosure of DG set cap 20 KVA by taking down and replacing the door hinges and door lock including all M&L and as directed. 204 Supply only distilled water into battery capacity of 12/24 Volt 88/90/180 AH all as specified and as directed by Engineer-in-Charge. 205 Taking out old burnt out Automatic voltage regulator from DG setcapacity 15 KVA to 35 KVA alternator and replace with new AVR and includingtesting and checking voltage regulation ofthe DG set on full loadfor its satisfactory performance complete all as specified and directed by Engineer-in-Charge:- 206 M&L for dismantling of complete radiator assy for DG Set capacity 15KVA to 35 KVA from engine and taking out all, de scaling rusty, sludge and muddy particles inside the radiator by using of sodium hydroxide with water pressure cleaning complete, changing of radiator fan belt if required and re-fixing the radiator assy on its existing position and testing complete for its satisfactory performance with entire satisfaction of Engineer-in-Charge:- 207 M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm buried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanized iron strip 25mm x 4mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire babric (APM) weight not less than 4 Kg/ Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and as directed by Engr-in-Charge. 208 Providing and fixing 25mm x 5mm G.I strip in 40 mm Dia G.I pipe from earth electrode including connection with G.I Nut, bolt, Spring, Waher excavation and refilling etc. as required. 209 Supply & Fix in replacement MCB SP 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 210 Supply & Fix in replacement MCB SPN 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 211 Supply & Fix in replacement MCB TPN, 40 -63 Amp, C-curve, 415 volt AC complete all as specified. 212 Supply & Fix in replacement AMF controller, three phases, 50 Hz, AC, auto/manual/test/off mode with necessary display complete all as specified. 213 Material & Labour for dismantling the alternator of DG Set of capacity 20 KVA to 75KVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connection of the alternator, shifting the alternator to workshop by crane and vehicle, opening into parts, checking all winding like main stator/rotor winding, exciter stator/rotor winding. Rewinding the main rotor and exciter rotor by using the “F” class insulation and existing gauge and type of magnet wire which was on original motor, varnishing, heating, drying, greasing the bearing including replacement unserviceable bearing ,re-fixing the complete including connection to the terminal box of the alternator at workshop and shifting the same to the site, fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with engine connecting all electrical connection of the alternator and testing the DG set “OFF/ FULL LOAD” , matching to the existing range of RPM of the engine output voltage for 415 volt and testing complete all as per the direction of Engineer In Charge. 214 Material & Labour for taking down unserviceable heat insulation from exhaust piping and providing new heat insulation to exhaust pipe using 50 mm thick mineral wool inside the container & up to the exhaust stack. The insulation shall be cladded/ covered with 24G aluminium sheet. Pipe length shall be maximum up to12 Meter long from engineincluding necessary welding works, cladding works with wire mesh and aluminium foil, replace unserviceable supporting MC,angle iron 50 mm X 50 mm X 6 mm, suitable size flange, nut, bolt and washers as required includingweather cowl complete all as specified. 215 Material & Labour for dismantling carefully fuel injection pump (FIP) up to 6 cylinders engine of DG set and transporting to workshop, opening into parts, for maintenance, servicing, overhauling, tuning and calibration, adjustment of nozzle pressure and other controls, replacement of unserviceable spares, re-assembling, re-fixing the FIP on its original position including to and from conveyance charge from site to workshop and back complete all as specified. 216 Material & Labour for dismantling exhaust manifold from the engine to detect the smoke leak, clean the manifold including welding works, replacement of unserviceable spares, packing, bellows, nut, bolt, washers, insulators, etc. reassembling and re-fixing on its base, testing by running the DG set No LOAD/FULL LOAD complete all as specified. 217 S&F in repair 1.5 Sqmm three core PVC insulated, unsheathed multi stranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge. 218 M&L for preparation of old paintedsurfaces of the DG set and fuel tankof following capacity by cleaning oily and greasy spots using CTC and material and labour for one coat of synthetic enamel paint using spray machine to the fuel tank and one coat of heat resistance paint to Engine / alternator complete all as specified and directed. 219 Note: - Colour code to be followed as under:-(i) Engine body - OG.(ii) Alternator - Siemens grey(iii) Fly wheel guard - Red(iv)Radiator -Black(iv)DG set canopy/complete body with two coats of superior qualitysynthetic enamel paint using spray gun (Area of painting not exceeding 3 sqm) including writingof incoming/outgoing feeder with letters, MES/SM Nos etc completeall as specified. For DG Set capacity 15 KVA to 35 KVA 220 M&L for disconnection of Diesel Oil tank with inlet and outlet diesel pipe line hose/pipe and cleaning of complete oil tank and drain out slug, muddy oil particle complete and re-fixing after at the same place and connecting complete with existing system including marking of tank showing the capacity in Ltrs and replacement of transparent PVC pipe complete all as directed by Engineer-in-Charge:-For DG Set capacity15KVA to 35KVA 221 Supply, install, testing & commissioning in repairs controller- Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connections good and renewed for up to DG set 35 KVA as per existing make complete all as specified and directed by Engr-in-charge. 222 M & L for Servicing of split type Air-conditioning unit comprising Indoor and Outdoor unit of any make/type having capacity 1.0/1.5/2 TR including attending breakdown including required tools and plants,minor electrical sparer like small piece of wire, insulation tape , screws required to rectify the complaints by replacing the spare partsin technical andresidentialbuildingat 14 ASC Kakkanad. Note: Spares required is measured and paid as respective items in Schedule A and all specified and directed by the Engineer - In - Charge. 223 Supply and charge refrigerant gas R-32/R-410 at site including testing all as specified and as directed by Engineer in charge . 224 Supply only Capacitor 36/40 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 225 Supply only Capacitor 50/60 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 226 Supply only Capacitor 80/100MFD suitable for 230 V 50 HZ AC supplyall as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 227 Taking out existing burnt fan motor single phase 230 Voltfrom the unit at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the followingall as specified and as directed by Engineer - in - Charge. 228 Splittype AC capacity up to 1.5 Ton 229 Split type AC 2.0 Ton Capacity 230 Taking out old unserviceable PCB and replace the same with new PCB at site suitable for window/split type AC of capacity 1/1.5/2 TR all as specified and directed by Engg-in-charge 231 Taking out carefully existing defective sealed unit compressorSupply & fixing factory made rotary type sealed compressor unit same as per existing model and make including charging the gas and testing & commissioning under normal condition of following rating complete all as specified and directed by Engineer - in - Charge. 232 (a) Split type Ac 1.5/2.0 Ton capacity 233 Removing the damaged insulation of suction and discharge line & Supplying and fixing new Thermal sleeve insulation for suction line and discharge line including providing hard plastic tape over the thermal insulation of split type A/C 1.5 / 2.0 Ton capacity etc complete all as directed by Engineer - in - Charge. 234 M&L in replacement of old unserviceable remote by providing new remote suitable for window type/ split type AC of any capacity/any make as specified and directed by Engineer in Charge. 235 Supply only new capacitor of Fan motor of 4 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 236 Supply only new capacitor of Fan motor of 10 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 237 Suply only split type AC indoor unit oscillation motorcomplete all as directed by Engineer - in - Charge. 238 Supply only thermostat for split type AC 1.0/1.5/2.0 complete all as directed by Engineer - in - Charge. Make: INDFOSS / RANTROL / ANNAPURNA. 239 Supply & fix in replacement of factory made MS bracket or Stand duly painted suitable for outdoor unit of split AC including making good disturbed surfaces etc. , all as specified andas directed. 240 M & L Removing the split A/c unit from existing position, of capacity 1.5/2.0 Ton of any make and refix the same in other location by fixing the indoor and outdoor unit in position on fixing on wall/ floor as directed including piping refix the insulation, Gas charging filling the cavities on wall setting of grills alignment complete including, testing & commissioning to the entire satisfaction of Engineer - in - Charge. 241 Supply and fixreplacement 240V 20 Amp singlepole and earth enclosure with a two pin and earth plug and socket complete with one single poleMCB20 Amp SPAll as directedEIC .Make: Legrand , Cat No: 6078 41/Equivalent in L & T/Indo Asian. 242 Taking down the old sub main wiring and M/L for new sub main wiring with 2 run single core 4.0 sq mmPVC unsheathed copper multi stranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow, saddles etc of white/lvorycolour PVC conduit including multi stranded copper earth conductor 4.0 sq mm one run as earth continuity conductor all as directed by Engineer in Charge. 243 Supply and fixing in replacement of LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Havells Cat Part No ENDURAPEARLNEOSL45LED757PASYTOPC or its equivalent make of Crompton/Bajaj/HPL/GM. 244 Supply, fixing, connecting and testing in replacement of 150 Watt LED flood light 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Havells Cat No JETAIRISFLS150WLED757PSYMLTG or its equivalent make of Crompton/GM/HPL. 245 Supply and fixing in replacement to ground with suitable pole mounting with OD of 76 mm, connecting and testing 40 Watt LED Post Top Luminaire, 230 Volt AC outdoor type with decorative post top for 360° indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Crompton Cat Part No LPTO-40-CDL/M or its equivalent make of Havells/Bajaj/GM/HPL. 246 Supply and fixing passing through pole cable 3 core PVC insulated unsheathed multi stranded copper conductor of size 2.5 Sqmm from junction box to lightfitting all as directed by EIC. Make: Havells/Finolex/Poly cab. 247 Supply & fixing in replacement of transparent cover type street light junction box of size 168 mm x 253 mm x 115 mm made of high quality thermoplastic type with hinged and 4 Nos DIN mounted terminal suitable for 10 Sqmm XLPE cable, IP-66 (Dust and power jet Proof according to IEC 60529) , shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated (Class II ) made of halogen and silica free recyclable material, UV resistant having high grade gasket made of poly-urethane with copper bus bar 25 x 5 mm -04 strip, one noMCB SP 6 Amps with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to, 10Sqmm cable etc and fixing to the street light pole with 02 Nos, 25 x 3 mm thick MS clamps, nuts & bolt, etc. complete all as specified and directed. Make: Hensel Cat Part No KG 9002 or its equivalent make. 248 M & L for removal of existing treatment from PCC poles and applying two coats of weather proof exterior emulsion paint on old painted surface over a coat of primer, complete all as specified and directed by Engineer-in-Charge. 249 M&L for cleaning of feeder pillar/ panel after dismantling the Incoming and outgoing connections from MCBs and replacing the old unserviceable Gland, lugs, nuts & bolts, push buttons, indicating lamps, supporting insulators etc., and checking the serviceability of MCBs, cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed by Engineer-in-Charge.Note: Spares / materials charge for repair/replacement of worn-out parts shall be measured and paid separately under relevant items. 250 S & F in replacement of MCCB 4 Pole 100-125 Amps 415V 16 KA 251 S & F in replacement of MCB TPN63Amp, 4 Pole, C Curve 252 S & F in replacement of MCB DP 32-40Amp, C Curve 253 S & F in replacement of MCB SP 6 to 32Amp, C Curve 254 Comprehensive Maintenance, Servicing and carrying out periodical service to Voltage Stabilizer, servo type of capacity 63 KVA, 3 phase, 50 c/s, AC including along withrepairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at siteall as specified and directed by Engr in charge. Notes: 255 (a) Any additional parts required to be replaced will be measured and paid separately as Supply only against appropriate item of schedule. However labour element and painting involved in replacement are included in quoted rate against this item. 256 (b) Any minor repairs involved to make the voltage stabilizer functional if notified by the Engr-in-Charge shall be carried out by the contractor without any extra cost to the department. (c) Following parts (if renewed) shall be measured and paid separately under appropriate items at Supply only rates and unserviceable parts retrieved through replacement shall be measured under Sch of credit. 257 Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 63 KVA, 3 phase, 50 c/s, AC supply of Make- Volteck or as per existing make and overhauling of the same by cleaning, servicing all serviceable accessories including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed.NOTE: - (i) Supply only spare parts shall be measured and paid separately under relevant items of this schedule. (ii)Transportation charge / labour charge during the repair of voltage stabilizer from the site to workshop are included in the items of this schedule 258 Supply only following spare parts of 63KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - 259 AC synchronous motor single phase, 50 Hz, 240 volts Make:UNI STEP or equivalent make suitable for volteck servo . 260 Variable auto transformer (Variac). 261 Sensing Transformer. 262 Carbon brush with holder complete. 263 Solid state sensing circuit. 264 RC Net work. 265 PCB connector. 266 Gear big. 267 Carbon fingers. 268 Variac Control CT. 269 Main Bushing with brass rod (insulator & rod). 270 High low cut off relay. 271 Series transformer. 272 Wiring Set. 273 Gear small. 274 Transformers oil filtering with test 275 Replacement of electronic control board 276 Fixing of top cover after repair and testing up to entire satisfaction of Engr in Charge. 277 Supply, installation, testing and commissioning of street light timer control panel, on pole/wall/floor mounting made out of CRCA steel sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements as per manufactures recommendation and design complete all as specified and as directed.Make: Havells Cat Part No IHXTS09120 or its equivalent make of above specification. 278 S&F bracket for fixing to street light poles, made out of suitable dia for fitting of LED street light fittingsmedium grade GI pipe bend to shape inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paintall as directed by the Engineer-in- Charge. Make: TATA / Jindal / Surya Praksh. 279 Supply, install, test and commissioning of outdoor type double door LT Feeder pillar box made out of 3.15 mm thick CRCA sheet outdoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved with front opening suitable locking arrangement having copper bus bar of 300 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level comprising of the following etc complete all as specified and directed by Engineer-in-Charge. Note: Cost of necessary internal wiring from bus bar to MCCBs/MCBs/Enclosure connections etc shall be deemed to be included in the unit rate. 280 Incoming:(a) MCCB 200 Amp 4 pole 36 KA Ics=100% of Icu with spreader & rom -01 No. (b) Indication Lamp Red/Yellow - 03 No (c) SP MCB 6A -03 Nos (d) MFM Meter with CT- 01 No (g) Provision for installation of KESB 3 Phase meter with necessary accessories. 281 Outgoings.(a) 125 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (b) 100 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (c) 63 A 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No.(d) 32 Amp 4 MCCB 16 KA, Ics=100% of Ics with spreader & rom -01 No. 282 M & L for re-filling of chemicals (minimum 25-30 ltrof Bentonite chemical / Graphite compound for each earth pit) in existing chemical earthing at technical area for achieving satisfactory earthing value with comprising of the Bentonitecomponents including necessary excavation/drilling for lift of cylindrical copper tubes from the ground and re-fixing the same by using Rig machine and providingenclosure with heavy duty plastic cover having locking arrangement including changing of electrode with pure copper chemical earthing electrode (length ofRod : 3 mtr Approx) for excellent conductivity & work efficiencycomplete all as specified and as directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
16.
Power #10782777 Price Bid
Tender for Round the clock Routine, Preventive and Breakdown Maintenance works of Bowl Mills (XRP-903), Raw Coal Feeders & Coal Pipes and round the clock dragging, accumulating, lifting and shifting of Coal Mill Reject (CMR) to specified places within theHTPS and General Cleaning of Mills/Fans areas etc. of Unit #8&9, DTPS, HTPS, Kasimpur for 02 years. - Round the clock routine and preventive maintenance of Bowl mills & RC-feeders of Unit No:-8 (03shift X 730 days =2190) 2 Round the clock routine and preventive maintenance of Bowl mills & RC-feeders of Unit No:-9 (03shift X 730 days =2190) 3 Round the clockoperationPLC Auto/Manual from mill site and compressorsfor coal mill reject system and routine/preventive break-down maintenance of pneumatic coal mill reject handling system & compressor with air receiver tank and air pipe lines etc along with the house keeping of reject system and nearby areaof Unit No:-8 & 9( (03shift X 730 days =2190) 4 Break-down Maintenance works of Bowl mills (XRP- 903)of Unit no-8 or 9 of 2X250 MW, DTPS, HTPS, Kasimpur, Aligarh. 5 Replacement of Roller Journal assembly(One RJ assembly makes one job) ( Time of Job completion = 08 Hrs.) 6 Changing trunnion position of RJ assembly. (One trunnion of one mill makes one Job) ( Time ofJob completion = 04 Hrs.) 7 Replacement of worn out grinding roll with new/healthy one, including servicing of RJ assembly.(Time of Job completion = 24 Hrs.) 8 Overhauling of pressure spring assembly (One spring assembly of any mill shall be considered as one quantity.)( Time of completion = 08 Hrs.) 9 Servicing/ repairing of spring support cover by machining/ tapping etc.(Time of completion = 08 Hrs.) 10 Replacement / Servicing of journal stop bolt..(Time of completion = 04 Hrs.) 11 Attending dust leakage from Journal opening cover. .(Time of completion = 04 Hrs.) 12 Replacement of bull ring segment assembly when replacement of RJ assembly has been given as separate job ( Separate job for removing and fixing of all three RJ assembly shall be given).(Time of completion = 16 Hrs.) 13 Replacement of bull ring segment assembly while at least one RJ assembly is inside the bowl mill.(Time of completion = 24 Hrs.) 14 Refitting of dislocated clamping ring/bull ring segment when replacement of RJ assembly has been given as separate job( Separate job for removing and fixing of all three RJ assembly shall be given).(Time of completion = 16 Hrs.) 15 Refitting of dislocated clamping ring/bull ring segment while at-least one RJ assembly is inside the bowl mill.(Time of completion = 24 Hrs.) 16 Replacement of airport ring assembly, when replacement of RJ assembly has been given as separate Job. Complete one set (one set consist of 06 pieces).(Time of completion = 48 Hrs.) 17 Repairing of airport ring assembly in installed condition when replacement of RJ assembly has been given as separate job (Separate Job for removing and fixing of all three RJ assembly shall be given).(Time of completion = 12 Hrs.) 18 Repairing of airport ring assembly in installed condition while at-least one RJ assembly is inside the bowl mill.(Time of completion = 12 Hrs.) 19 Repairing/Replacement of bowl extension ring segment, when replacement of RJ assembly has been given as a separate Job.(Time of completion = 12 Hrs.) 20 Repairing/Replacement of venturi, while replacement of MPO & MDV are awarded as separate Job.(Time of completion = 12 Hrs.) 21 Repairing/Replacement of venturi, while MPO & MDV are in their installed condition.(Time of completion = 24 Hrs.) 22 Repairing of venturi outlet in installed condition.(Time of completion = 08 Hrs.) 23 Replacement of MPO.(Time of completion = 48 Hrs.) 24 Replacement of MDV.(Time of completion = 24 Hrs.) 25 Replacement of (leaking) Victaulic coupling rubber gasket of MPO/ MDV/ transition piece.(Time of completion = 04 Hrs.) 26 Replacement of classifier inner cone,when replacements of RJ assemblies have been given as separate Jobs.(Time of completion = 48 Hrs.) 27 Fabrication and fixing of air ductvanes.(Time of completion = 08 Hrs.) 28 Repairing ofO collar assembly.(Time of completion = 06 Hrs.) 29 Repairing eroded portion of classifier inner cone.(Time of completion = 04 Hrs.) 30 Replacement/refitting/Servicing of classifier blade.(Time of completion = 04 Hrs.) 31 Adjustment of classifier blade operating linkage mechanism.(Time of completion = 08 Hrs.) 32 Replacement /Repairing of scrapper guard assembly.(Time of completion = 04 Hrs.) 33 Replacement of mill side liner, when replacement of RJ assembly has been given as a separate Job.(Time of completion = 24 Hrs.) 34 Repairing of Mill side liners by patching/welding (MS plate of thickness-10/12 mm for patching may be arranged from scrap).(Time of completion = 04 Hrs.) 35 Repairing/Replacement of mill side bottom liner.(Time of completion = 04 Hrs.) 36 Replacement of bottom insulation cover plate(complete set).(Time of completion = 24 Hrs.) 37 Repairing of bottom insulation cover plate.(Time of completion = 12 Hrs.) 38 Checking and inspection / Replacement of Labyrinth seal inside the mill liner body of mill.(Time of completion = 12 Hrs.) 39 Checking and inspection / Replacement of Labyrinth seal outside the mill liner body of mill.(Time of completion = 12 Hrs.) 40 Refitting/replacement of dislocated lower/upper skirt assembly.(Time of completion = 24 Hrs.) 41 Decoupling, performing alignment of mill-motor complete coupling and final coupling.(Time of completion = 12 Hrs.) 42 Replacement of damaged geared coupling of input shaft and distance piece with new-one (Healthy-one) and perform alignment.(Time of completion = 24 Hrs.) 43 Repairing of separator body, when replacement of RJ assemblies have been given as separate Jobs.(Time of completion = 24 Hrs.) 44 Replacement of bowl hub cover, when replacement of RJ assemblies has been given as separate Job.(Time of completion = 08 Hrs.) 45 Making threaded hole of any diameter on any surface of bowl mill by drilling and tapping.(Time of completion = 12 Hrs.) 46 Servicing of oil coolers of mills in installed condition (one cooler of one mill make one Job).(Time of completion = 24 Hrs.) 47 Replacement/Refitting of braided hose of lube oil pipe line.(Time of completion = 04 Hrs.) 48 Servicing of seal air valve on seal air header of mills.(Time of completion = 06 Hrs.) 49 Hard facing of bowl mill spares by 2 chequering pattern using sequence welding technique in installed condition.(Time of completion = 08 Hrs.) 50 Complete dense hard facing of cap of airport ring assembly & Bowl extension ring with hard facing electrode.(Time of completion = 04 Hrs.) 51 Fabrication and Replacement of RCF Hopper chute to center pipe of mill.(Time of completion =24 Hrs.) 52 Fabrication & Fitting of Guard/covering/shroud of RJ assembly housing by 8/10/ 12mm thick MS/Sailma plate.(Time of completion = 12 Hrs.) 53 Complete Overhauling of RJ assembly.(Time of completion = 16 Hrs.) 54 Servicing of Hot air gate.(Time of completion = 10 Hrs.) 55 Servicing of Hot air damper.(Time of completion = 10 Hrs.) 56 Servicing of Cold air gate.(Time of completion = 08 Hrs.) 57 Servicing of Cold air damper.(Time of completion = 08 Hrs.) 58 Attending coal/coal dust leakage from centre feed pipe/coal pipe {one patch (min size-200X200mm) make one Job)}.(Time of completion = 04 Hrs.) 59 Servicing of lube oil system of mills (one mill make one Job).(Time of completion = 16 Hrs.) 60 Servicing of oil coolers of mill lub. oil system by taking out the cooler from the lube oil system. (One cooler of one mill make one Job).(Time of completion = 48 Hrs.) 61 Servicing of lube oil pump ofBowl mills.(Time of completion = 08 Hrs.) 62 Replacement of lube oil pump of bowl mill with new /overhauled/serviced pump.(Time of completion = 04 Hrs.) 63 Metalizing & hard facing of clamping rings of bull ring segment (All 4 rings make one job). Metalizing welding electrode is in firm scope. Hard facing to be done with L&T 670/700 welding electrode which shall be provided by Nigam.(Time of completion = 24 Hrs.) 64 Repairing / Welding work in Cold air Duct/ Hot air duct.(Time of completion = 06 Hrs.) 65 Changing worn out coal pipe (full length or piece) / bend with new one (One pipe/bend make one Job).(Time of completion = 24 Hrs.) 66 Changing of worn out /damaged centre feed pipe of milling system.(Time of completion = 24 Hrs.) 67 Cleaning, Greasing, Servicing of electrically operated hoist (One job of one unit for fifteen days).(Time of completion = 16 Hrs.) 68 Servicing of all electrically operated hoist of mill site.(one unit make one job of7+ 1 under hung crane + hoist ).(Time of completion = 40 Hrs.) 69 Taking out one no. complete RJ assembly from any bowl mill while taking-out journal openingcover.(Time of completion = 08 Hrs.) 70 Fixing of one no RJ assembly in any bowl mill when Journalopening cover is already opened.(Time of completion = 08 Hrs.) 71 Checking and inspection/Replacement of (If found damaged) bearings with new one ofinput shaft of planetary Gearbox of Bowl Mill.(Time of completion = 48 Hrs.) 72 Replacement of broken bolt ofmill body to separator top and bottom liner.(Time of completion = 24 Hrs.) 73 Shifting of healthy RJ assembly from mill floor (3.5 mtr.) of unit no:- 8 to unit no:- 9 mill floor ( 3.5 mtr.) and vice versa.(Time of completion = 04 Hrs.) 74 Repairing and reconditioning of eroded portion of bowl (erosion due to worn-out of bull ring segment) in installed condition by metalizing, hard facing of bowl surface with bull ring segments erosion size up-to or less than 4 x 4 of 1 Segment.(Time of completion = 48 Hrs.) 75 Repairing and reconditioning of eroded portion of bowl (erosion due to worn-out of bull ring segment) in installed condition by metalizing, hard facing of bowl surface with bull ring segments erosion size more than 4 x 4 of 1 Segment erosion size more than4 x4 and up-to 6 x 5 of 1 Segment.(Time of completion = 72 Hrs.) 76 Repairing and reconditioning of eroded portion of bowl (erosion due to worn-out of bull ring segment) in installed condition by metalizing, hard facing of bowl surface with bull ring segments erosion size more than 4 x 4 of 1 Segment erosion size morethan 6 x 5 of 1 Segment.(Time of completion = 96 Hrs.) 77 Breakdown & Maintenance / Overhauling work of Gravimetric Coal Feeders 250 MW 78 Replacement of COC Gear Box with new/serviced gear box.(Time of completion = 08 Hrs.) 79 Servicing / Rectification of defects of clean out conveyor ofGCF.(Time of completion = 08 Hrs.) 80 Servicing/repairing of span/ weigh span roller.(Time of completion = 04 Hrs.) 81 Repairing of end door.(Time of completion = 04 Hrs.) 82 Servicing/repairing of air operated feeder outlet gate.(Time of completion = 08 Hrs.) 83 Servicing /repairing of manual Feeder inlet gate/bunker outlet gate.(Time of completion = 08 Hrs.) 84 Servicing of seal air valve of GCF.(Time of completion = 08 Hrs.) 85 Servicing of defective COC Drive (Quadruple Helix-worm unit).(Time of completion = 15 Hrs.) 86 Replacement /Repairing of belt scrapper.(Time of completion = 04 Hrs.) 87 Attending dust leakage from GCF body by welding/patching etc.(Time of completion = 04 Hrs.) 88 Servicing/Overhauling of Gravimetric Coal Feeder Main gear box.(Time of completion = 12 Hrs.) 89 Replacement / Servicing of Gravimetric Coal Feeder Head Pulley/power pulley/take-up pulley.(Time of completion = 08 Hrs.) 90 Servicing of Gravimetric Coal Feeder.(Time of completion = 16 Hrs.) 91 Servicing of clutch assembly.(Time of completion = 08 Hrs.) 92 Replacement of damagedfeeder belt with new one of Gravimetric Coal Feeder.(Time of completion = 24 Hrs.) 93 Replacement of Main Gear Box of GC Feeder with new/serviced gear box.(Time of completion = 08 Hrs.) 94 Replacement of clutch assembly of GC Feeder with new/serviced.(Time of completion = 08 Hrs.) 95 Repairing/Replacement of grating of various sizes.(Time of completion =Hrs./m².) 96 Round the clock lifting and shifting of CMR, General Cleaning and removing of of choking from Mills ofUnit# 8& 9, DTPS 97 Round the clock lifting and shifting of coal Mill rejects spelled outfrom Pyrite Hopper and Mills (at ‘0’ Meter) of Unit # 8 & 9, 2X250MW, HTPS, Kasimpur to Coal yard of old Plant / 2X250 MW Plant or other specified places within theHTPS, Plant. 98 Filling and shifting of coal Mill reject from SILO system of Mill reject system of Unit # 8 & 9, 2X250MW, HTPS, Kasimpur to Coal yard of old Plant/2x250 MW Plant or other specified places within theHTPS, Plant. 99 Cleaning of mill floor (‘0’ & ‘3.5’ meter), mill associated auxiliaries, pulverize coal pipes, structure of mill, duct connected to mill at 3.5 meter floor, classifier top, Removing of settled coal/coal dust at Hot air gate/cold air gate and its platform, and ID/FD/ PA/Seal air fan foundation floors of Unit # 8. 100 Cleaning of mill floor (0 & 3.5 meter), mill associated auxiliaries, pulverize coal pipes, structure of mill, duct connected to mill at 3.5 meter floor, classifier top, Removing of settled coal/coal dust at Hot air gate/cold air gate and its platform, and ID/FD/ PA/Seal air fan foundation floors of Unit #9. 101 Cleaning of Feeder floor & associated structure to feeder floor of Unit # 8 . 102 Cleaning of Feeder floor & associated structure to feeder floor of Unit # 9. 103 Removal of major chocking of bowl mill & center pipe of bowl mill (From feeder outlet gate to liner body of mill) of Unit # 8. 104 Removal of major chocking of bowl mill & center pipe of bowl mill (From feeder outlet gate to liner body of mill) of Unit # 9. 105 Removal of major chocking of Coal feeder of Unit # 8. 106 Removal of major chocking of Coal feeder of Unit # 9. 107 Removal of major chocking of Coal feederbelt of Unit # 8. 108 Removal of major chocking of Coal feeder belt of Unit # 9. 109 Cleaning of P.A. duct internally from hot air gate to mill side liner body of Unit # 8. 110 Cleaning of P.A. duct internally from hot air gate to mill side liner body of Unit # 9. 111 Maintenance of Coal Pipes 112 TO ATTEND THE CHOCKING OF COAL PIPE 113 PATCH WORK ON COAL PIPE (DURING SHUT DOWN OF MILL) SIZE- 200MMX200MMM 114 CHANGING OF VICTAULIC COUPLING GASKET 115 REPLACEMENT OF COAL PIPE HANGERS. 116 REPAIRING OF COAL PIPE BENDS AT DIFFERENT ANGLES AT POSITION.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Uttar Pradesh View Result →
17.
Tourism #10734916 AOC
Tender For Restoration Conservation And Site Development Work For Prayag Tirtha, Trimbakeshwar, Nashik- 1 Removal of plants / ficus grown by pulling out root system embedded in masnory,cutting stem and application of high/gur/lime formulation as specified by theArchitect or other patented chemical biocide treatment such as biocide Glycel (iso proplamine salt of glyphosate) or other chemical as specified by the Engineer in charge etc. complete. 2 Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete 3 Dewatering on BHP basis by using water pump including diversion of stream,providing cofferdams,earthern bunds etc.as may be necessary for foundation and other parts of the works and pumping out water during and after excavation as may be required by using 3.0BHP pump etc. complete. (prior approval of Superintending Engineer will benecessary) 4 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. 5 Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. 6 ProvidingSoil Bag Support to the monument with contractor´ssoil in proper layers carefully as directed by Engineer in-charge including filling, tying and conveying the bags,removing the soil bags after work up to a distance of 50 meter beyond the monument area and cleaning the siteetc. complete. A) While lowering the Members 7 ProvidingSoil Bag Support to the monument with contractor´ssoil in proper layers carefully as directed by Engineer in-charge including filling, tying and conveying the bags,removing the soil bags after work up to a distance of 50 meter beyond the monument area and cleaning the siteetc. complete. B) While restoring the members 8 Numbering the monument elements in proper order before lowering down with approved colour and shade as directed by Engineer in-charge, including ladder, scaffolding etc. complete. 9 Loweringdowncarefullyexistingstonemasonryofthemonumentmanuallyinproperorder including shifting the stone elements up to a distance of 50 meter beyond the monument area and stackingthemasdirectedby Engineerin-charge,removingbuilding rubbishandcleaning thesite etc. complete. 10 Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc. 11 Providing Un-coursed Rubble Masonry of trap / granite stones in lime mortar 1:1½, in foundation and plinth as per detailed specifications and drawings or as directed including the stones to be set in the work as received from the quarry, after merely knocking off weak corners and edges with the masons hammer, the stones shall be carefully laid so as to break joints, no joint shall exceed 12.5 mm. (½″) in thickness, every stone shall be set flush in mortar, the face stone shall be for greater size, and good beds, one through stone shall be inserted at least every 0.80 sq. mete (1 square yard), the joints shall be racked out carefully at least 25 mm. (1″) where pointing or plastering to be done, striking joints where no pointing or plastering is to be done, preparing the lime mortar in lime miller, bailing out water, watering and all exposed masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete.. 12 Providing/Re-setting Ashlar Fine Masonry of reuse-stones in lime mortar 1:1 in superstructure asperdetailedspecificationsanddrawings oras directed including the stonesshallbesetin fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course, the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. 13 Providing Ashlar Fine Masonry of trap / granite stones in lime mortar 1:1 with average size of stone 90 cm. x60 cm. x21.5cm. in superstructureas per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete.For Top copingoftank wall 14 Providing Ashlar Fine Masonry of trap / granite stones in lime mortar 1:1 with average size of stone 70 cm. x70 cm. x30cm. in superstructureas per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete.For side wall of tank & 2 shrines 15 Providing Ashlar Fine Masonry of trap / granite stones in lime mortar 1:1 with average size of stone 225 cm. x 50 cm. x 45 cm. in superstructureas per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. completeFor making Entry gate Beam 16 Carving ornamental work on surface including moulding, grove, chisseling & dresing the same part with fine finishing as per existing/similar type of work of on the stone surface of any type & size or as directed by engineer in charge etc. complete. The charges for chiseling & dressing on stone surface for ornamental carving work surface etc. as per existing design. pattern and form as directed by engineer in charge 17 Carving ornamental work including moulding, grove, clhisseling & dresing the same part with fine finishing as per existing/similar type of work of on the stone surface of any type & size or as directed by engineer in charge etc. complete. 18 Providing and laying cast in situ 1:1:4 Lime Concrete of broken brick metal for coping or waterproofing as per detailed specifications and drawings or as directed including centring, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required, with fine aggregate, preparing the lime mortar in lime miller and then mixing with coursed aggregate or surkhi in drum mixer, the concrete must be bitten for two days with pouring water as per specifications, scaffolding, watering and all concrete work when handed over to be perfectly clean and free from all mortar stains, etc. complete 19 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. 20 Providing and laying cast in situ 1:2:4 Lime Concrete of trap/ granite/ quartzite/ gneiss metal for foundation and bedding as per detailed specifications and drawings or as directed including bailing out water, centring, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required with fine aggregate, preparing the lime mortar in lime miller and then mixing with coursed aggregate in drum mixer as per specifications including bailing out water, watering etc. complete. For Plum Concrete. (30% Rubble Supply) 21 Providing and fixing Stone Paving, First Sort in lime mortar 1:1, with average size of stone 60 cm. x 45 cm. x 15 cm. as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be very finely chisel-dressed on the surface and the course to be of prescribed width, the joints running true, the stonestobelaidwithjointsnotexceeding 6mm.(¼″)thick andtobe evenlyandfirmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all pavingwork when handed over to be perfectly clean and free from all mortar stains etc. complete. For Pavement. 22 Providing Lime Pointing to stone work in lime mortar 1:1 in plinth, as per detailed specifications and drawings or as directed including all face or visible work shall be pointed, unless otherwisespecified and shall be done while the mortar is fresh, the mortar shall consists of lime and fine sandshall not be ground fine but sand should be finer, the joints of the pointed work shall be neatlydefined by the pointing, the lines shall be regular and uniform in breadth and the joints shall beraised or flat as may directed, preparing the lime mortar with 640 gram pulp of wood apple(Belfruit) per cubic metre of lime mortar as a bonding material, watering and all work whenhanded over to be perfectly clean and free from all mortar stains etc. complete 23 Gently cleaning the surface of stone masonryand piers withspecialized water misting techniques employing air water jetusing a fine nozzle sprinkling system calibrated to spray finemist along the stone surface without over wetting followed upby gentle brushing with soft nylon brushes and removing dirt,dust, bird dropping, grease. oil, algae, flingus, monkey beats,vegetable growth etc.as specified. Gentle surface cleaningmay, include using water misting and mild pH balancedsurfactants as specified for indicated areas to remove thesurfce dirt, grit accretions by means of water misting andcleaning etc. complete as directed by the Engineer in Charge.(The rate is inclusive of all materials & labours involved exceptscaffolding). 24 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m.beyond the buildingarea & stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means 25 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 26 Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. 27 Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in superstructure including racking out joints when plastering is to be done / striking joints when no plastering is to be done on inside watering and scaffolding etc.complete 28 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete 29 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints,wateringand scaffolding etc. Complete 30 Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for coping as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 31 ProvidingandfixinginpositionHCRM/CRS(Corrosion ResistantSteel)barreinforcementof various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns,canopies, staircase, newels,chajjas,lintelspardis,copings,fins,archesetc.asperdetailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 32 Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete 33 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 34 Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat Reflective Paint) 35 Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. 36 Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete 37 Providing structural steel work in hollowsection of various thickness and sizes insquare, rectanular and round shape from 25mm to 450mm section as per IS4923 YST 310 Grade produced from iron or eand blast furnace route etc.as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing inposition, making riveted/bolted/ welded connections and painting complete. 38 Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) 39 Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofingwithoutwindtiles includingfasteningwithgalvanisedironscrewsand bolts, lead and bitumenwashers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). 40 Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete.(Weight of 6.8 kg/sq.m.). 41 Providing and fixing Mangalore tiled roofing with class AA tiles including securing the last course of tiles near the eaves with steel flat 40 mm x 3 mm and 1.22 mm wire fixing 50 mm x 25 mm horizontal teak wood battens and iron works and oiling the battens etc. complete. (Excluding ridge and hip tiles). 42 Providing and fixing Mangalore tile ridge and hip tiles of class AA including scaffolding if necessary, pointing with coloured cement mortar and curing etc. complete. 43 Providing and laying Cast in situ/Ready Mix cement concrete in M15 oftrap/ granite/quartzite/gneissmetal for base of foundationas per dwg and directionincluding steelcentering, formwork, laying/pumping,compacting, roughening them if special finishis to be provided, finishing uneven and honey combed surface and curing etc.complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombedsurface,only. Newly laid concrete shall be covered by gunny bag, plastic,tarpaulin etc. (Wooden centeringwill not be allowed.),with fullyautomatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batchmix plant (Panmixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) 44 Providing and laying machine cut machine Polished Kota stone flooring 25 mm to 30 mm thickand required width in plain/ diamond pattern on bed of 1:6C.M. including cement float, filling joints with neat cement slurry curing, polishing and cleaning etc.complete. 45 Providing and laying Polished Tandur Stone flooring 25mm to 30mm thick required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. 46 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 47 Supplying and stacking of good earth at site including royalty andcarriage up to 1 km (earth measured in stacks will be reduced by20% for payment). 48 Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). 49 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 4.75 mm 50 Rough dressing the trenched ground including breaking clods. 51 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. 52 Fine dressing of the ground 53 Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately). 54 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. 55 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately).In rows 5 cm apart in both directions 56 Providing and fixing Black stone bench Specification - black stone bench Size-48LX14W×20H With 6×6-2supports to base and 1 inserted inside stone 57 Disposing off / conveying the dismantelled materials of stone masonry/ brick masonry/ concrete/ debris/ excavated material / soil murrum / rubbish material or vegetation / grass / shrubs etc. from site to 5 Kmas directed by Engineer incharge 58 Providing and fixing board displaying in formation, suchas Name of work,Tender cost,Name of Contractor,Work completion and liability period etc,having rectangular shape of 1.20 m x 0.90m size made out 18gauge(1.25mm) thick mild steel sheet painted withone coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border/messages/symbolsetc.with approved colourshade paint complete,on M.S.angle of size35x35x3mm frame with properly crossbraced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angleiron posts of size 65mmx65mmx6mm,3.65m long painted with alternate black andwhite bands of 25 cm width including all fixtures etc.and fixing theboards in1:4:8concrete block of size 60 cmx 60 cmx 75 cm including, excavation, refilling,transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge
Contract Date: Apr 24, 2026 Contract Value : 7.20 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
18.
Tourism #10734556 AOC
Restoration, Conservation And Development Work At Mukundeshwar Temple And Mukund Talab, Trimbakeshwar, Nashik- 1 Removal of plants / ficus grown by pulling out root system embedded in masnory,cutting stem and application of high/gur/lime formulation as specified by theArchitect or other patented chemical biocide treatment such as biocide Glycel (iso proplamine salt of glyphosate) or other chemical as specified by the Engineer in charge etc. complete. 2 Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete 3 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. 4 Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. 5 Numbering the monument elements in proper order before lowering down with approved colour and shade as directed by Engineer in-charge, including ladder, scaffolding etc. complete. 6 Loweringdowncarefullyexistingstonemasonryofthemonumentmanuallyinproperorder including shifting the stone elements up to a distance of 50 meter beyond the monument area and stackingthemasdirectedby Engineerin-charge,removingbuilding rubbishandcleaning thesite etc. complete. 7 Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc. 8 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. Additional Item Spec. No. : As directed by Engineer in charge. 9 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m.beyond the buildingarea & stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means 10 Removingtheexistingcementplasterofanythicknesswithoutcausingdustnuisanceand stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete. 11 Raking out joints in lime or cement mortar and preparing the surface forre-pointing or replastering including disposal of rubbish to the dumpingground within 50 metres lead. 12 Providing Un-coursed Rubble Masonry of trap / granite stones in lime mortar 1:1½, in foundation and plinth as per detailed specifications and drawings or as directed including the stones to be set in the work as received from the quarry, after merely knocking off weak corners and edges with the masons hammer, the stones shall be carefully laid so as to break joints, no joint shall exceed 12.5 mm. (½″) in thickness, every stone shall be set flush in mortar, the face stone shall be for greater size, and good beds, one through stone shall be inserted at least every 0.80 sq. mete (1 square yard), the joints shall be racked out carefully at least 25 mm. (1″) where pointing or plastering to be done, striking joints where no pointing or plastering is to be done, preparing the lime mortar in lime miller, bailing out water, watering and all exposed masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete.. 13 Providing/Re-setting Ashlar Fine Masonry of reuse-stones in lime mortar 1:1 in superstructure asperdetailedspecificationsanddrawings oras directed including the stonesshallbesetin fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course, the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete. 14 Providing Ashlar Fine Masonry of trap / granite stones in lime mortar 1:1 with average size of stone 70 cm. x70 cm. x30cm. in superstructureas per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. complete.For face wallin wall 15 Providing Ashlar Fine Masonry of trap / granite stones in lime mortar 1:1 with average size of stone 225 cm. x 50 cm. x 45 cm. in superstructureas per detailed specifications and drawings or as directed including the stones be of approved quality, colour, hard and free from defect of any kind,dressing every stones fine tooled on all beds, joints and faces, full true if the surface are plane or to uniform curves or twists if required, the stones shall be set in fine mortar, the beds or joints being in no case more than 3 mm. (⅛″), the stone shall be laid in regular course not less than 30 cm. (12″)in height averaging 4½ c. ft., the face stone shall be laid header and stretcher alternately, preparing the lime mortar in lime miller, scaffolding, wateringandall masonry work when handed over to be perfectly clean and free from all mortar stains etc. completeFor making Entry gate Beam 16 Carving ornamental work on surface including moulding, grove, chisseling & dresing the same part with fine finishing as per existing/similar type of work of on the stone surface of any type & size or as directed by engineer in charge etc. complete. The charges for chiseling & dressing on stone surface for ornamental carving work surface etc. as per existing design. pattern and form as directed by engineer in charge 17 Carving ornamental work including moulding, grove, clhisseling & dresing the same part with fine finishing as per existing/similar type of work of on the stone surface of any type & size or as directed by engineer in charge etc. complete. 18 Providing and laying cast in situ 1:1:4 Lime Concrete of broken brick metal for coping or waterproofing as per detailed specifications and drawings or as directed including centring, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required, with fine aggregate, preparing the lime mortar in lime miller and then mixing with coursed aggregate or surkhi in drum mixer, the concrete must be bitten for two days with pouring water as per specifications, scaffolding, watering and all concrete work when handed over to be perfectly clean and free from all mortar stains, etc. complete 19 Providing and fixing Stone Paving, First Sort in lime mortar 1:1, with average size of stone 60 cm. x 45 cm. x 15 cm. as per detailed specifications and drawings or as directed including all stone slabs to of approved quality, hard, even, sound, durable and uniform thickness, the stones to be very finely chisel-dressed on the surface and the course to be of prescribed width, the joints running true, the stonestobelaidwithjointsnotexceeding 6mm.(¼″)thick andtobe evenlyandfirmly bedded flush in mortar on the concrete and no hollow left, side to be dressed true and as per shape at least half the depth from the face, preparing the lime mortar in lime miller, watering and all pavingwork when handed over to be perfectly clean and free from all mortar stains etc. complete. For Pavement. 20 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. 21 Providing and laying cast in situ 1:2:4 Lime Concrete of trap/ granite/ quartzite/ gneiss metal for foundation and bedding as per detailed specifications and drawings or as directed including bailing out water, centring, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required with fine aggregate, preparing the lime mortar in lime miller and then mixing with coursed aggregate in drum mixer as per specifications including bailing out water, watering etc. complete. For Plum Concrete. (30% Rubble Supply) 22 Providing and grouting with lime and fine screened sand slurry in proporation of (1 : 1) with a proper jet pump pressure including cleaning and washing and packing the existing crack / holes in the brick or stone masnory with lime and finesand paste in proporation of (1:1) properly from down side, filling the slurry in cracks or holes including all necessary actions and required tools and machineries, scaffolding, curing etc. complete. 23 Gently cleaning the surface of stone masonryand piers withspecialized water misting techniques employing air water jetusing a fine nozzle sprinkling system calibrated to spray finemist along the stone surface without over wetting followed upby gentle brushing with soft nylon brushes and removing dirt,dust, bird dropping, grease. oil, algae, flingus, monkey beats,vegetable growth etc.as specified. Gentle surface cleaningmay, include using water misting and mild pH balancedsurfactants as specified for indicated areas to remove thesurfce dirt, grit accretions by means of water misting andcleaning etc. complete as directed by the Engineer in Charge.(The rate is inclusive of all materials & labours involved exceptscaffolding). 24 Providing Lime Pointing to stone work in lime mortar 1:1 in plinth, as per detailed specifications and drawings or as directed including all face or visible work shall be pointed, unless otherwisespecified and shall be done while the mortar is fresh, the mortar shall consists of lime and fine sandshall not be ground fine but sand should be finer, the joints of the pointed work shall be neatlydefined by the pointing, the lines shall be regular and uniform in breadth and the joints shall beraised or flat as may directed, preparing the lime mortar with 640 gram pulp of wood apple(Belfruit) per cubic metre of lime mortar as a bonding material, watering and all work whenhanded over to be perfectly clean and free from all mortar stains etc. complete 25 Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, watering including shoring and strutting etc. complete.complete. (Lift from 1.5 to 3.0 m) By Manual Means 26 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 27 Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. 28 Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in superstructure including racking out joints when plastering is to be done / striking joints when no plastering is to be done on inside watering and scaffolding etc.complete 29 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete 30 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints,wateringand scaffolding etc. Complete 31 Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for coping as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 32 ProvidingandfixinginpositionHCRM/CRS(Corrosion ResistantSteel)barreinforcementof various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns,canopies, staircase, newels,chajjas,lintelspardis,copings,fins,archesetc.asperdetailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 33 Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete 34 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 35 Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat Reflective Paint) 36 Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. 37 Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete 38 Providing structural steel work in hollowsection of various thickness and sizes insquare, rectanular and round shape from 25mm to 450mm section as per IS4923 YST 310 Grade produced from iron or eand blast furnace route etc.as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing inposition, making riveted/bolted/ welded connections and painting complete. 39 Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) 40 Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofingwithoutwindtiles includingfasteningwithgalvanisedironscrewsand bolts, lead and bitumenwashers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). 41 Providing and fixing Mangalore tiled roofing with class AA tiles including securing the last course of tiles near the eaves with steel flat 40 mm x 3 mm and 1.22 mm wire fixing 50 mm x 25 mm horizontal teak wood battens and iron works and oiling the battens etc. complete. (Excluding ridge and hip tiles). 42 Providing and fixing Mangalore tile ridge and hip tiles of class AA including scaffolding if necessary, pointing with coloured cement mortar and curing etc. complete. 43 Providing and laying Cast in situ/Ready Mix cement concrete in M15 oftrap/ granite/quartzite/gneissmetal for base of foundationas per dwg and directionincluding steelcentering, formwork, laying/pumping,compacting, roughening them if special finishis to be provided, finishing uneven and honey combed surface and curing etc.complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombedsurface,only. Newly laid concrete shall be covered by gunny bag, plastic,tarpaulin etc. (Wooden centeringwill not be allowed.),with fullyautomatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batchmix plant (Panmixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) 44 Providing and laying machine cut machine Polished Kota stone flooring 25 mm to 30 mm thickand required width in plain/ diamond pattern on bed of 1:6C.M. including cement float, filling joints with neat cement slurry curing, polishing and cleaning etc.complete. 45 Providing and laying Polished Tandur Stone flooring 25mm to 30mm thick required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. 46 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 47 Supplying and stacking of good earth at site including royalty andcarriage up to 1 km (earth measured in stacks will be reduced by20% for payment). 48 Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). 49 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 4.75 mm 50 Rough dressing the trenched ground including breaking clods. 51 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. 52 Fine dressing of the ground 53 Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately). 54 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. 55 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately).In rows 5 cm apart in both directions 56 Providing and fixing Black stone bench Specification - black stone bench Size-48LX14W×20H With 6×6-2supports to base and 1 inserted inside stone 57 Disposing off / conveying the dismantelled materials of stone masonry/ brick masonry/ concrete/ debris/ excavated material / soil murrum / rubbish material or vegetation / grass / shrubs etc. from site to 5 Kmas directed by Engineer incharge 58 Providing and fixing board displaying in formation, suchas Name of work,Tender cost,Name of Contractor,Work completion and liability period etc,having rectangular shape of 1.20 m x 0.90m size made out 18gauge(1.25mm) thick mild steel sheet painted withone coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border/messages/symbolsetc.with approved colourshade paint complete,on M.S.angle of size35x35x3mm frame with properly crossbraced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angleiron posts of size 65mmx65mmx6mm,3.65m long painted with alternate black andwhite bands of 25 cm width including all fixtures etc.and fixing theboards in1:4:8concrete block of size 60 cmx 60 cmx 75 cm including, excavation, refilling,transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge
Contract Date: Apr 24, 2026 Contract Value : 4.38 Crore
Government Departments No of Bidders 4
Maharashtra View Result →
19.
Public Administrative Department #10714170 Price Bid
Civil Work For Auditorium For Nagar Parishad, Dausa, Rajasthan Civil Work For Auditorium For Nagar Parishad, Dausa, Rajasthan EARTH WORKClearing Grass and Removal of Rubbish (Maximum 150mm) by manual means and disposal at a lead of 50 metres as per MoRT&H specification clause 201. 2 Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawings). In all type of soil. Upto 3.0 m depth. 3 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m. 4 Add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.1.1 5 In ordinary rock. Depth upto 1.5 M. 6 Add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.2.1 7 Carriage of Materials by mechanical transport including loading, unloading and stacking ::Upto 1 Km 8 Stone, boulders, gravelly materia 9 Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. 10 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which approach is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion). 11 Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRT&H specifications with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification including all material, labour, machinery as per clause 710.1.4 of IRC:78 and clause 2200 of MoRT&H specification. 12 CONCRETE WORK 13 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 14 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 15 REINFORCED CEMENT CONCRETE 16 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix). 17 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement :1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix) 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-30 Grade Concrete. 19 Reinforced cement concrete work in arches, arch ribs, domes, vaults, shells, folded plate and roofs having slope more than 15° upto two stories excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 20 Providing and laying upto two stories reinforced cement concrete in kerbs, steps and the like excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 21 Add extra for laying reinforced cement concrete above two stories (or 7.50 mtr height above plinth level) for every one storey or 3.00 m height or part thereof. 22 Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 23 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 24 Suspended floors, roofs, landings, balconies and access platform. 25 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 26 Columns, Pillars, Piers, Abutments, Posts and Struts.22.1.5 27 Stairs, (excluding landings) except spiral-staircases. 28 Extra for shuttering in circular work (20% of respective centring and shuttering items). 29 Edges of slabs and breaks in floors and walls. Under 20 cm wide. 30 Weather shade, Chajjas, corbels etc., including edges. 31 Add extra for doing centering and shutteriing work for every additional height of 1 metre or part thereof beyond initial 7.5 metre height from plinth level. 32 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. 33 BRICK / STONE MASONERY WORK 34 Brick work with FPS bricks of class designation 75 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand). 35 Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand). 36 Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories. Cement mortar 1:3 (1 cement :3 coarse sand). 37 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 38 Random rubble stone masonry work in cement mortar with mechanical mixer in foundation (at any level) complete as per drawing and technical specification and as per clause 1000 and 1400 of MoRT&H specification including all scaffolding material, labour, machinery but excluding pointing and plastering. In cement mortar 1:4 (1 cement : 4 coarse sand). 39 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Green / Black Above 3601 Cm2 Slabs. 40 Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work. Moulding. 41 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 42 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 43 Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles 44 Providing and fixing Motive pieces all coloures for glazed tiles laid over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white mixed with pigment of matching shade complete. Size 200 x 300mm. 45 P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm. 46 Providing and fixing 1st quality MAT & GLOSSY finished ceramic tiles colour such as standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the the cost of cement mortar bed 1:4) Size 300mm x 450mm. 47 Providing and fixing 1st quality ceramic glazed vitrified tiles of colour standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete. (excluding the the cost of cement plaster on wall and pillar). Size 600mm x 1200mm 48 38mm thick wood block flooring of first class teak wood laid over 25mm thick levelling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10mm nominal size) to be paid separately coated with a thin layer of hot bitumen (blown type) @ 2.45 kg per sqm. including fixing blocks in position after dipping in hot bitumen (blown type) upto half depth, planed, levelled smooth and finished complete. 49 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 50 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. Red sand stone. 51 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 52 ROOFING 53 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design In 75x75mm deep chase. 54 Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80mm thick with zinc coating not less than 275gm/m². 55 Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 square decimetre 0.80 mm thick 56 Providing and fixing 15 cm wide 45 cm over all semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 0.80mm thick with zinc coating not less than 275gm/m² 57 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine/ coarse sand) 58 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand). 59 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 60 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 61 18 mm thick moulded cement mortar band in two coats under layer 12mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) toplayer 6mm thick with cement mortar 1:4 (1 cement : 4 fine sand). Design on outer plaster. 62 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 63 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 64 Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). 65 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work. 66 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 67 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8193, density 16kg/m3 , 50mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing GI wire. 68 Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving screws, over expansion joints on vertical surfaces/ceilings with full threaded, cadmium plated steel screws 4mm dia. stem, 30mm long and aluminium washers 2mm thick, 15mm dia. at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete. Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron). 69 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width. 70 Providing and laying expansion joint complete as per drawing and technical specification and as per clause 2605 of MoRT&H Specification including all material, labour, machinary etc. 71 Fillar joint with 20m thick compressible fibre board. 72 Fillar joint with Joint sealing compound with coarse sand and 6 %bitumen by weight. 73 Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: Hot finished seamless type tubes. 74 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 75 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C 76 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S. tube. 77 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 78 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides including approved ISI marked Stainless Steel butt hinges fittings with necessary screws complete as per annexure A : 30 mm thick Decorative teak veneer both side. 79 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured). Decorative teak veneer both side. 80 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) Rectangular or square. 81 Extra for cutting rebate in flush door shutters for making double leaf shutter(Total area ofthe shutter to be measured). 82 Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete. 50 mm long. 83 Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: 20 mm dia. 84 Providing and fixing to existing door frames. 30mm thick factory made solid both side Pre-laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded Pre-laminated PVC C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side Pre-laminated PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification & drawing (for W.C. and bathroom door shutter). 85 ALUMINIUM WORK 86 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : For fixed portion. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). 87 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron). 88 Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre-laminated one side decorative lamination on other side balancing lamination Grade I, Type II, IS : 12823 marked including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete : 25 mm thick 89 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basicitem) : With float glass panes of 5.50 mm thickness. 90 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate. 91 Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineerin-charge complete. 355 X 19 mm. 92 INTERIOR WORK 93 FALSE CEILING 94 Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part I, 95 Sanitary Items 96 Plumbing 97 Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts collar and bush of approved quality and colour. 98 15 mm nominal bore with 3 cm length. 99 15 mm nominal bore with 45 cm length. 100 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. 101 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 102 15 mm nominal bore 103 20 mm nominal bore 104 25 mm nominal bore 105 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 106 25 mm nominal bore Horizontal 107 25 mm nominal bore Vertical 108 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 109 Sanitary 110 Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 : Upto 300 mm dia. 111 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : 112 100 mm dia. pipe 113 125 mm diameter pipe 114 Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead : 115 100 mm diameter pipe 116 125 mm diameter pipe 117 Supplying pig lead at site of work. 118 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 200 mm diameter 119 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 120 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With bricks with class designation 75 121 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With bricks class designation 75 122 Providing and fixing square-mouth S.W. gully trap grade A’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type With bricks class designation 75. 123 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design With bricks. 124 Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design With bricks 125 Fixtures 126 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. 127 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated levers. 128 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm. 129 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 130 Rectangular shape 453x357mm 131 Rectangular shape 1500x450 mm 132 Providing and fixing 100 mm sand cast Iron grating for gully trap 133 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 134 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 100 mm outlet 135 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15 mm nominal bore 136 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. 137 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm deep and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-incharge and finished smooth. Granite Stone of approved shade 138 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. 139 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. 140 Internal work - Exposed on wall 15 mm dia. nominal bore 141 Internal work - Exposed on wall 20 mm dia. nominal bore 142 Internal work - Exposed on wall 25 mm dia. nominal bore 143 Internal work - Exposed on wall 32 mm dia. nominal bore 144 Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 15 mm dia. nominal bore 145 Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 20 mm dia. nominal bore 146 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 147 15 mm dia. nominal bore 148 20 mm dia. nominal bore 149 25 mm dia. nominal bore 150 32 mm dia. nominal bore 151 Painting G.I. pipes and fittings with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for new work : 152 15 mm dia. nominal bore 153 20 mm dia. nominal bore 154 25 mm dia. nominal bore 155 32 mm dia. nominal bore 156 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 157 15 mm dia. nominal bore 158 20 mm dia. nominal bore 159 25 mm dia. nominal bore 160 32 mm dia. nominal bore 161 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 162 15 mm nominal bore 163 20 mm nominal bore 164 25 mm nominal bore 165 WATER HARVESTING SYSTEM 166 Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes but excluding cost of casing pipes as per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe: 200 mm dia Nominal bore 167 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985 of following nominal bore sizes at site of work. 200 mm dia 168 Supply and fixing of M.S. clamp set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 169 Providing & lowering of G.I. flange pipe B Class including rubber washer and nuts of 8 mm dia complete in all respect. 50 mm dia 170 Development of tube well as per IS specification using suitable compressor to give sand free water for required yield of the gravel packed tube well. 171 ELECTRICAL G-SCHEDULE 172 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its accessories, round tiles,18 SWG M.S. box with earth terminal, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. 173 Short point (up to 3 mtr.) 174 Medium point (up to 6 mtr.) 175 Long point(up to 10 mtr..) 176 Wiring of twin control light / fan / call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its accessories, round tles,18 SWG M.S. box with earth terminal, 6 A two way switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. 177 Short point (up to 3 mtr.) 178 Medium point (up to 6 mtr.) 179 Long point(up to 10 mtr..) 180 Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm FR PVC insulated unsheathed 1.1 kV grade flexible copper conductor and 1.5 sq.mm FR PVC insulated unsheathed 1.1 kV grade copper earth conductor (IS:694) of approved make double lock/ ISI marked single lock pvc casing capping & its accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & falce ceiling point, 6 A switch, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 181 On board 182 Short point (up to 3 mtr.) 183 Medium point (up to 6 mtr.) 184 Long point(up to 10 mtr..) 185 S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall and making good the same as required. 186 20 mm 187 25 mm 188 32 mm 189 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 190 3x 1.5 sq.mm 191 2 x 2.5 sq. mm. + 1x1.5sqmm 192 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 193 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 194 4 x 10.0 sq.mm 195 4 x 16.0 sq.mm 196 Supplying and drawing PVC jacketed with annealed bare copper inner conductor & tinned copper conductor shielding foam PE dielectric coaxial cable of approved make in existingsurface or recessed conduit/casing capping including making connections as required. 197 RG - 6 198 RG -11 199 Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured/ armoured telephone cable with 0.5 mm dia. Tinned / annealed copper conductor taped &confirming to ITD specification S/WS-112C &113 C of approved make in existing surface or recessed conduit/casing capping. 200 Unarmoured 2 pair 201 Unarmoured 10 pair 202 Unarmoured 20 pair 203 Unarmoured 50 pair 204 Jelly filled armoured (PIJF) 5 pair 205 Jelly filled armoured (PIJF) 10 pair 206 Jelly filled armoured (PIJF) 20 pair 207 Jelly filled armoured (PIJF) 50 pair 208 P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar masking sheet conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. Double door (Three phase) Per phase isolation 209 2+8 Way 210 2+12 Way 211 Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 212 2.5 Sq. mm 4 core 213 4.0 Sq.mm 4 core 214 6.0 Sq.mm 4 core 215 10.0 Sq.mm 4 core 216 16.0 Sq.mm 4 core 217 25.0 Sq.mm 3.5 core 218 35.0 Sq.mm 3.5 core 219 50.0 Sq.mm 3.5 core 220 70.0 Sq,mm 3.5 core 221 95.0 Sq.mm 3.5 core 222 120.0 Sq.mm 3.5 core 223 150.0 Sq.mm 3.5 core 224 240.0 Sq.mm 3.5 core 225 300.0 Sq.mm 3.5 core 226 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 227 3.5 x 25.0 sq.mm 228 3.5 x 35.0 sq.mm 229 3.5 x 50.0 sq.mm 230 3.5 x 70.0 sq.mm 231 3.5 x 95.0 sq.mm 232 3.5 x 120.0 sq.mm 233 3.5 x 150.0 sq.mm 234 3.5 x 240.0 sq.mm 235 3.5 x 300.0 sq.mm 236 4 x 2.5 sq.mm 237 4 x 4.0 sq.mm 238 4 x 6.0 sq.mm 239 4 x 10.0 sq.mm 240 4 x 16.0 sq.mm 241 Supply, Fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. Hot Dipped Galvanized. 242 150mm x 50mm x 1.6mm 243 300mm x 50mm x 1.6mm 244 450mm x 50mm x 2.0mm 245 600mm x 50mm x 2.0mm 246 Maintenance free gel earthing with pipe in pipe /Strip in Pipe technology filled with anti corrosive conductive compound (CPRI tested) below the ground in 150 -200 mm dia earth pit and surrounding filled with required mineral filling compound (MFC should have hygroscopic proper ty to retain the moisture for long time to create low resistance Zone) and C.C. finished chamber covered with hinge type with locking arrangement C.I cover. C.I. frame of size 300mm x300mm complete testing of earth resistance as required of following sizes With pipe in pipe technology (inner pipe dia / outer pipe dia) 80 -100 micron G.I. coating With pipe in pipe technology with 80-100 micron G.I. coating G.I. pipe 3000 mm long , 80/40 mm , terminal 14 mm G.I. strip 247 S & Laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 248 8 SWG copper Wire 249 25mm x 3mm copper strip 250 50mm x 6mm copper strip 251 25mm x 3mm G.I. ( Hot Dipped) Strip 252 25mm x 6mm G.I. ( Hot Dipped) Strip 253 P & F of IP20 LED Recessed/ Surface Mounted Round/ sqaure Non Dimmable Downlight with die-cast aluminum housing & Heat sink for heat dissipation, high purity reflector with external driver having efficiency > 85% and in compliance to IEC standards. ( supplied together with luminaire) Power consumption of =< 7w/10w/8w/12w/15w/18W with 100/500/750/1100/1250 lumens, system lumen, efficeancy of 70 lm / Watt or 100 lm / Watt output suitable to replace 1x18W/ 2x18w/2x26w CFL downlights, life time of 50000 Burning Hours with 70% of intial Lumen maintained. CCT 3000° K, 4000° K and 6000° K. Fixture shall be CE Compliance. 254 Recessed mounting LED Downlight 18/20W 255 Surface Mounting LED Downlight 18/20W 256 P & F of IP20 LED Ceiling/ Recessed/ suspended mounting light fixture made form CRCA sheet steel housing, high purity/ transmisivity diffuser for uniform light distrubution.High efficiency driver electronics having efficiency > 85% and in compliance to IEC standards.(integral driver). Power consumption of 40 W/50W/60W, 3000/3300/4200 lumens, system lumen efficiency of 70-80 lm / Watt output suitable for 2x36W FTL/ 2x36w CFL/3x36w CFL light fixtures, life time of 50000 burning Hours with 70% intial Lumens maintained. CCT 3000° K, 4000° K and 6000° K. Fixture shall be CE compliance. Surface Mounting 36W LED Light 2’x2’ with acrylic/ prismatic front cover 257 P & F energy efficient direct fit (Retrofit) LED tube system (with integral driver), on existing fixture. Power Consumption of18W / 36W 1500-3000 lumens, system lumen efficiency 80 lm/Watt output, life time of 50,000 burning hours with 70% initial lumen maintained. CCT 3000°K, 4000°K& 6000°K. 4 LED Tube shape fixture 18W. 258 P/ F IP-65/ IP-66 protected street light luminaries on existing bracket. Fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power LEDs . Diffuser / glass cover for ensuring IP-65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance. IP-65 protected LED street light luminaries LED street light fixture 150 watt 259 Supply and erection of Octagonal pole of following length and dimension as per table-3 with base plate on the cement concrete foundation of M-15 /M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III ). The pole shall be made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning. 9 Mtr. 260 Supply, Installation, Testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer (+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5% of the maximum total loss values for 11 KV as per energy efficiency level - 2 at basic Insulation level conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014. Transformers described as above and as per the following continuous rating. 315KVA 261 Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 11 KV Incomer VCB panel up to 630 A equipped with following switchgears and accessories designed & tested as per latest standard i.e. IEC 62271-200, suitable for STC 25KA/3 and IAC A-FLR for 25kA/1sec. Make of HT Panel, Vaccum Interrupter and VCB should be of same make. 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-12 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer, Ammeter, analog type, selector switches for ammeters, Microprocessor based numerical relay with O/L, E/F and S/C protection, Set of dual core dual ratio 3CTs of suitable ratio with sec 1 of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection, Multifunction Meter. 262 SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.Alternator shall be self regulated with standard Alternator Protection( Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping , electronic / Mechanical governor, Manual & electric Start, Batteries, Fuel tank ( with Stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183 .The doors are fabricated from 1.6 mm CRCA sheet packed with accoustic material, floor of MS chequrred plate 5.0 mmthick, All doors/ opening are sealed with neoprene/ EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 °C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system mccb Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. Lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 db (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity : Radiator cooled and turbo charged 250 KVA at 0.8 pf 415V 50Hz 3-?. 263 Supply, Installation, Testing & Commissioning of HT metering cubical panel as approved By DISCOMs fabricated out of 14 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX6mm having provision for Following: (i) Provision for fixing Trivector Meter (To be supplied by DISCOMs) (ii) Provision for fixing of combined CT PT Set (To be supplied by DISCOMs) (iii)TT Block (iv) 6mm Bakelite sheet on all sides. 264 Supply, Installation, testing and commissioning of 11 KV Double Pole structure With Air Break SWITCH having following specifications : (a) DP : Double pole structure made of two nos. 9 meter long PCC poles (400 Kg) & 7 nos. MS Channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required. (b) GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3 phase, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 Nos pin insulator ,GI pipe of suitable length for operation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set / Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Post insulators. (c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators (d) LA:3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. (e) JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ 265 FIRE ALARM G-SCHEDULE 266 SITC of microprocessor based 2 - wire loop (each loop accessing 90 addressable units ) Fire Alarm Control Panel. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. The Panel shall also be able to give voice announcement to individualized speakers. The Panel shall have built in sounder, Maintenance Free Batteries of minimum 15 Ah of 24 volts capable of minimum of 12 hours with battery charger, rectifier. Loop cards, LCD unit to indicate Fire / Fault Signal of individual unit, built in-built / external printer, to log all incoming data etc complete in all respect. 2-LOOP. 267 SITC Manual Call Point complete with , Glass, hammer and chain etc as required: Analogue addressable type 268 SITC Automatic commendable Control Switches for shutting downAC Plant, Power Supply, Gas Supply etc. Response Indicators. 269 SITC Fault Isolators for isolating shorted, dead wire and loose circuits between two successive Fault Isolators with automatic resetting arrangement. Analogue addressable type. 270 FIRE FIGHTING G-SCHEDULE 271 Sub Head - I - (Wet Riser System - Pumping Equipments)SITC of electric driven Sprinkler / Hydrant pump Suitable for automatic Operation consisting of the following-(A) Horizontal multi stage Centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary sluice value on the suction side ( all items to be matching the suction side of the pump) and pressure gauge sluice value and non return valve on the delivery side side ( all of the necessary dia) and including bypass arrangement for testing of pump.(B) Squirrel cage induction motor suitable for 415 V, 50 HZ, Ac supply of below mentioned HP for the above pump ,1450 RPM T.E.F.C confirming to IP:55 and flexible coupling and coupling guard with the pump. (C) Common bed plate fabricated from mild steel channel or cast iron type1620 LPM at 70 Mtr Head ( 50 HP Motor) 272 SITC of diesel engine drive Standby Pump suitable for automatic operation consisting of the following A, B, C. .The Diesel driven pump shall be suitable for following discharge:(A) Horizontal multi stage centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary flexible pipe, sluice value on the suction side (all items shall be matching the suction side of the pump) and pressure gauge, sluice valve and non return valve on the delivery side (all of the necessary dia) and including bypass arrangement for testing of pump.(B) Water cooled Diesel Engine developing suitable BHP for the below mentioned discharge at 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump, d cushy foot, damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically with a unit of battery of 12/24v, 88 Ah, 13/21 plate, Exhaust Pipe of minimum 10 M length, with muffler, day oil tank of 300 1ts capacity with first charge and hand operated oil pumpingset, Supply, installation, testing, & commissioning of electric driven automatic pressurization pump setC) Horizontally mounted single stage centrifugal end delivery pump of below mentioned discharge with necessary sluice valve on the suction side (all items matching the suction side of the pump) and sluice valve, non return value, pressure gauge on the delivery side including by pass arrangement for testing of the working of the pumping set as required.1620 LPM at 70 Mtr Head ( 50 HP Engine) 273 SITC of Jockey pump having Squirrel cage induction motor suitable for 415 V, 50 Hz AC supply with synchronous speed of 2900 RPM T.E.F.C type confirming to IP:55 and flexible coupling and coupling guard with the pump ,Common bed plate of fabricated mild steel channel or cast iron type. 180 LPM at 70 Mtr (15 HP). 274 Supplying & Installing cylindrical type air vessel, 250 mm dia 1.5M high of thickness 6.0 mm M.S. complete with air release valve, safety valve, pressure gauge etc.along with two coats of Red Oxide and two coat of post office red enamel paint as required. 275 Providing & fixing 100mm dia pressure Gauge on Pump DeliveryLine complete with shut off cock. 276 SITC of pressure switches for Main, Jockey, and standby pumps,including necessary wiring UPTO control panel and stop valve. 277 Sub Head - II - (Hydrants System) 278 Providing and fixing single headed hydrant valves with flanged inletISI marked with 63 mm female instantaneous outlet of gun metalcomplete with blank cap and chain conforming to IS : 5290 279 Providing . 63 mm dia 15 M long reinforced rubber hose pipeconforming to IS : 636-1962, Part –A & ISI marked with Gun Metalmale & female coupling wire wound with the pipe. 280 Providing & fixing (1.0 M x .45 M x 0.6 M ) OUTDOOR HOSECABINET suitable for accommodating hydrants made of not lessthan 16 swg. M. S. sheet having central opening glazed doorincluding necessary locking arrangement, painting (one coat primer& two coats of paint ) and housing 2 Nos. RRL hose pipe, 1 Nobranch pipe. 281 Providing and fixing Swinging Drum type hose reel ISI marked 30M(L) x 20 mm (dia) rubber lined pipe with shut off nozzle of 6 mm diaincluding the cost of 25 mm dia pipe connection from riser to hosereel , all sockets, nipples, elbows and 25 mm globe valve. 282 Providing and fixing ISI marked Three Way fire Brigade Inlet to wetRiser with non return valve complete in all respects 283 Providing, fixing, jointing and testing of Heavy Gauge (C class ) MSPipe ISI marked with accessories like tees, elbows, flanged joints,reducers, compressed asbestos gaskets, nuts and bolts includingfixing the pipe with suitable flat iron strip clamps /bracket, paintingetc. Complete as required for delivery/ suction manifold relating tothe pump including painting of two coats of Red Oxide and two coatof post office red enamel paint including all civil breakages andmaking good the same : 284 200mm dia 285 150 mm dia 286 80 mm dia 287 Sub Head - III - (Piping, Valves and Accessories) 288 MS (Medium duty B class) pipe with cleaning,wrapping and coatingof the pipe as per IS; 10221 in all kind of soil at 1.0 M depthincluding excavation as required. 289 150 mm dia 290 100 mm dia 291 80 mm dia 292 Providing & fixing Butterfly valve with Cast Iron Body, Cast Iron Discand Seat of Nitrile Rubber Bonded on Bakelite with hard back to PN1.6 rating with following sizes complete with bolts, washers andcompressed asbestos gasket as required 293 150 mm dia 294 100 mm dia 295 80 mm dia 296 Providing and fixing non return valve complete with bolts nuts washers and compressed asbestos gasket etc as required : 297 200 mm dia 298 150 mm dia 299 80 mm dia 300 Carbon Dioxide type fire extinguisher with cylinder fully charge of 4.5kg capacity. 301 Providing, fixing, testing & commissioning of sprinkler heads of thefollowing type : Pendant type with quartziod bulb, operating temperature at 68 deg Cas per specifications. 302 Providing & fixing 10 SWG chrome plated brass 100 mm diadecorative flanges / escutcheon plates to be fixed at junction ofSprinkler piping with the false ceiling. 303 Sub Head - III - (Piping, Valves and Accessories) 304 Sub Head - IV (Fire Electrical Control Panel) 305 Supplying and making end termination with heavy copper lugs (pin/ring type) duty crimped with crimping tool, PVC tape etc of followingsize 306 1.5 Sq.mm 307 10.0 Sq.mm 308 35.0 Sq.mm 309 Supply, Fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. 100mm x 50mm x 1.6mm 310 BOUNDARY WALL G-SCHEDULE 311 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m 312 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 313 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 314 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix) 315 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-30 Grade Concrete. 316 Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 317 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 318 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars 319 Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Raised and cut pointing. 320 Random rubble stone masonry work in cement mortar with mechanical mixer in foundation (at any level) complete as per drawing and technical specification and as per clause 1000 and 1400 of MoRT&H specification including all scaffolding material, labour, machinery but excluding pointing and plastering. In cement mortar 1:4 (1 cement : 4 coarse sand) 321 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 322 EARTH WORK 323 Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m. 324 Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawings). In all type of soil Upto 3.0 m depth. 325 EXTERNAL DEVELOPMENT 326 Compacting original ground 327 Loosening upto a level of 500 mm below the subgrade level watered, graded and compacted in layers by vibratory roller 8-10 tonne to meet requirement of table 300-2 for subgrade construction as per MoRT&H specification clause 305.3.4. 328 Loosening and recompacting original ground below embankment including Loosening leveling and recompacting original ground supporting embankment to facilitate placement of of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling by vibratory roller 8-10 tonne so as to achieve minimum dry density as given in table 300-2 for embankment construction as per MoRT&H specification clause 305.3.4. 329 Providing, laying, spreading (with paver finisher only) and compacting wet mix macadam (WMM) base course comprising of graded stone aggregate and granular material conforming to MORT&H specifications (Table 400-II) in layers of equal compacted thickness each consolidated, including pre-mixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub-base/ base course and compacting with power vibratory-roller to achieve the desired density complete as per MoRT&H specification clause - 406 including all material, labour, machinery, lighting, guarding and maintenance of diversion. 330 CEMENT CONCRETE PAVEMENTS 331 Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid manualy, compacting with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 332 Providing and laying un-reinforced, dowel jointed, plain cement concrete mix With Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. PCC M-30. 333 Providing and laying cast-in-situ cement concrete M-20 grade kerb stone channel top and bottom width 115 and 165 mm respectively, 250mm high laid with kerb laying machine, on 150 mm thick PCC M10 grade foundation (laid manually) as per design, including fixing at site as per clause 408 of MoRT&H Specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. Using Concrete Mixer. 334 Providing and fixing of 60mm thick precast cement concrete interlocking paver block casted with rubber moulds in approved reflective colour and design having minimun compressive strength of 300 kg/ sq cm. The CC paving blocks be laid on average 50mm thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. 335 Flooring with Cobble stone of approx. Size 125x125x75 mm (thick) laid on 25 mm average thick cement mortar 1:3 ( 1 cement : 3 Coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved pattern complete in all respect as per direction of Engineer-in-charge. 336 Providing at site, lowering & laying in trenches, aligning & jointing of RCC pipes NP4 class (with s/s ends) IS: 458 - 2003 (amended up to date) marked and pipes from 300 mm and upto 1800 mm manufactured through vertical casting process at all depths with Rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of Rubber gaskets, lubricants) as per drawing, sectional hydro testing of the sewer pipe line (including cost and conveyance of water to site for testing) etc., complete as per specification and / or as directed by Engineer. Note : E/w to be measured and paid separately. 300 mm internal diameter. 337 Horticulture Work 338 Grassing with Doobs grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. In rows 7.5 cm apart in either direction. 339 Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 900 mm min. height plants at site in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 340 Ficus panda 341 Tecoma capensis ( Ratanjot) 342 Clerodendron inermii ( Choti Aari) 343 Tabernaemontana variegated ( Chandni) 344 Hamelia patens ( Firebush, Thal Kamal) 345 Hibiscus variegated ( Guddal) 346 Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 300 mm min. height ground covers at site in 0.3 m dia holes, 0.3 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 347 Wedelia trilobata ( SunFlower Family) 348 Alternathera green (Parrot Leaf) 349 Iresine herbstii (Blood Leaf) 350 Ophiopogon Black ( Lily Turf, Mondograss) 351 Asparagus myerii (Fox Tail) 352 Lantana sellowiana 353 Rhoeo spathacea Compacta‘ ( Oyster, Boat Lily) 354 Golden duranta 355 Pennisetum setaceum (Fountain Grass)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
20.
Drinking Water Supply and Sanitation #10713558 Price Bid
Different Works Related To Water Supply Scheme At Duna & Its Adjoining Mouzas Water Supply Scheme Within Mayureswar-Ii Block Including Supply Of All Labour & Materials Underbirbhum Division, Phe Dte. ( Sl. No.11 ) - Sinking Of Tubewell- 3 Nos. ( Annexure I ) Site Preparation, Temporary Latrine, Placement & Levelling Of Rig Machine, Mast Hoisting And Casing Drilling ( Upto 6 Mtr. ) Placement Of Casing With All Allied Works Necessary To Commence Drilling Woks And Wind Up Of All Machineries After Completion Of Drilling. 2 Drilling By Direct Rotary Method Of Drilling Using9 7 / 8” Dia.Bit For Pilot Bore Follwed By Subsequently Reaming Using 12 1 / 4” Dia. , 15 Dia. And 17.5 Dia. Rock Roller Bits / Drag Bits In Consolidated, Semi Consolidated And Soft Formation Up To Required Depth Including Casing Boring And Casing Lowering As Required Includingcost Of Fuels And Lubricants Etc. As Required For Drilling.Note:1 ) Rate Only For Pilot Drilling Will Be @ 50%. Of Item Rate.2 ) Ratefor Reaming By 12 1 / 4 Dia. Bit Will Be @ 14% Of Item Rate.3 ) Ratefor Reaming By 15 Dia. Bit Will Be @ 16% Of Item Rate.4 ) Ratefor Reaming By 17.5 Dia. Bit Will Be @ 20% Of Item Rate. From 6 Mtr. To 60 Mtr. 3 From 60 Mtr. To 90 Mtr. 4 From 90 Mtr. To 120 Mtr. 5 From 120 Mtr. To 150 Mtr. 6 From 150 Mtr. To 180 Mtr. 7 Lowering The Tube Well Assembly ( Upvc Casing Pipe , Well Pipe, Strainer Along With Upvc Accessories ) Vertically In A Position With Proper Lowering Arrangement By Applying Necessary Jointing Compound Including Labour Cost For Subsequent Gravel Packing And Machine Operation Cost Etc. 8 Cost Of Consumables For Drilling Rigs And Machineries. 9 Development ( Min. 8 Hr. Continuous ) Of Tube Well By Using Suitable Air Compressor ( Min. Capacity: 600Cfm & Operating Pressure 14 Bar ) Followed By Yield Testing With Bht Pump ( Head :45 To 50Mtr., Discharge :1100 To 1000 Lpm And 25 Bhp Engine ) All Complete Includingto & Fro Transportation Cost And Cost Of Fuels, Lubricants & Labour Etc. 10 Water Sample Collection And Chemical Test Including Arsenic Test. 11 Transportation Cost Of Drilling Equipmentand Accessories Rig Machine Etc. Including Cost Of Fuel, Lubricant & Loading Unloadingthe Materials From Store / Stack Yard / Suppliers Godown And Unloading / Stacking The Same At Site. ( Upto 60.0 Km Distance ) 12 Supply And Delivery Of Upvc Pipe ( Cd ) Conforming To Is 12818:2010. ( Cipet Certified ) . ( 250 Mm Dia. ) 13 Supply And Delivery Of Upvc Pipe ( Cd ) Conforming To Is 12818:2010. ( Cipet Certified ) . ( 150 Mm Dia. ) 14 Supply And Delivery Of Upvcdeep Well Screen ( Rds ) Pipes With Ribs Conforming To Is 12818:2010 . ( Cipet Certified ) 150 Mm Dia. 15 Supply And Delivery Ofupvcreducer 250Mm X 150Mm Dia. 16 Supply And Delivery At Site Of Upvc End Cap. ( 250 Mm Dia. ) 17 Supply And Delivery At Site Of Upvc End Cap. ( 150 Mm Dia. ) 18 Supply And Delivery Of M.S. Housing Clamp 250 Mm Dia. 19 Supply And Delivery Of M.S .Centre Guide ( Special Type ) . 20 Supply And Delivery Of Washed Gravels Size Ranging From 1.80 Mm To 4.74 Mm. Conforming To Is 4097 : 1967. 21 Supply And Delivery Of Bentonite Powder Conforming To Is 6186 : 1986. 22 Electro-Logging Charge. 23 Trial Boring Of Tube-Welldrilling By Reverse Rotary Method Of Drilling Using9 7 / 8” Dia.Bit For Pilot Bore Follwed By Subsequently Reaming Using 12 1 / 4” Dia. , 15 Dia. And 17.5 Dia. Rock Roller Bits / Drag Bits In Consolidated, Semi Consolidated And Soft Formation Up To Required Depth Including Casing Boring And Casing Lowering As Required Includingcost Of Fuels And Lubricants Etc. As Required For Drilling.Note:1 ) Rate Only For Pilot Drilling Will Be @ 50%. Of Item Rate.2 ) Rate For Reaming By 12 1 / 4 Dia. Bit Will Be @ 14% Of Item Rate.3 ) Rate For Reaming By 15 Dia. Bit Will Be @ 16% Of Item Rate.4 ) Rate For Reaming By 17.5 Dia. Bit Will Be @ 20% Of Item Rate.From G.L. To 60 Mtr. 24 From 60 Mtr. To 90 Mtr. 25 From 90 Mtr. To 120 Mtr. 26 From 120 Mtr. To 150 Mtr. 27 From 150 Mtr. To 180 Mtr. 28 Cleaning Compound Premises Of Shrubs, Plants, Jungled Etc. As Per Direction Of E.I.C. 29 Soil Test For Ohr- 1 No. ( Annexure Ii ) Mobilisation Charges Of All Tools & Plants Along With Accessories, Material, Labour, Supervision Etc. At Site Of Work Required In Connection With Boring And Testing Work, Including Setting Up Boring Rigs And Shifting To Different Bore-Hole Points Etc. And Also Including Withdrawal Of Same From The Site After Completion Of Work, Complete As Per Direction Of Engineer-In-Charge. 30 Labour For Making Bore-Holes Of 150Mm To 250Mm Dia. By Any Standard Method To Any Depth Below Ground Level / Bed Level In All Kinds Of Soil Like Clay, Silt, Sand, Stiff Clay, Mixed Soils Etc. Except Rocks ( For The Purpose Of Collecting Disturbed & Un Disturbed Soil Samples, Conducting Standard Penetration Test At Suitable Intervals Etc. ) Including Preparation And Submission Of Bore-Log As Per Irc : 75 And 78 And Clause 2400 Of Specifications For Road & Bridge Works ( 5Th Revision ) , Published By Irc, And Also Including Hire Charges Of Tools And Plants Complete As Per The Direction Of Engineer-In-Charge.A ) When Casing Pipe Is Used To Prevent Collapse Of Bore Hole ( Casing Pipe To Be Finally Withdrawn ) I ) Depth 0 M To 10 M ( For 3 Nos Bore ) 31 Ii ) Depth Greater Than 10 M & Upto 20 M 32 Iii ) Depth Greater Than 20 M & Upto 30 M 33 Field Investigation :I ) Collection Of Undisturbed Soil Sample From The Bore Hole To Be Made By The Concerned Division / Party At Their Cost.A ) 0.00 - 10.0 M 34 B ) 10.00 - 20.0 M 35 C ) 20.00 - 30.0 M 36 Ii ) Collection Of Samples From The Bore Hole ( A ) Disturbed 37 Iii ) Standard Penetration Tests ( S.P.T. ) By Split Spoon Sampler In The Bore Hole As Per Is : 2131.A ) 0.00 - 10.0 M 38 B ) 10.00 - 20.0 M 39 C ) 20.00 - 30.0 M 40 Laboratory Investigation :I ) Liquid Limit As Per Is 2720 ( Part – V ) . 41 Ii ) Plastic Limit As Per Is 2720 ( Part – V ) 42 Iii ) Grain Size Analysis By Sieving As Per Is 2720 ( Part – Iv ) . 43 Iv ) Grain Size Analysis By Hydrometer Method As Per Is 2720 ( Part – Iv ) . 44 V ) Determination Of Water Content As Per Is 2720 ( Part – Ii ) . 45 Vi ) Determination Of Specific Gravity As Per Is 2720 ( Part – Iii ) . 46 Vii ) Direct Shear Test As Per Is 2720 ( Part – Xiii ) . 47 Viii ) Determination Of Unconfined Compressive Strength As Per Is 2720 ( Part-X ) ( I ) Undisturbed 48 Ix ) Determination Of Consolidation Properties As Per Is 2720 ( Part – Xiv ) . 49 X ) Tri-Axial Shear Test :A ) Determination Of Shear Strength Parameters Of A Specimen Tested Inunconsolidated Undrained Tri-Axial Compression Without Measurement Ofpore Water Pressure As Per Is 2720 ( Part –Xi ) . 50 Carriage Of All Disturbed & Undisturbed Samples From Site Of Work To The Divisional Office Or Elsewhere Including Loading And Unloading As Per Direction Of Engineer-In-Charge. Detailed Investigation. 51 Preparation And Submission Of Report In 6 ( Six ) Copies, Giving All Relevant Information Data Like Site Plan, Bore Log And Water Table, Test Results, Calculations, Discussions, Suggestions And Recommendations In Respect Of Suitable Foundation Etc. Including Determination Of Silt Factor Calculation Of Waterways And Complete Design Of Foundation Including Analysis Of Bearing Capacities And Settlements In Bound And Presentable Form Complete As Per Direction Of Engineer-In-Charge.Detailed Investigation. 52 Construction Of 300 Cum Ohr- 1 No. ( Annexure Iii ) Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Laterite Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete. A ) Depth Of Excavation Not Exceeding 1500 Mm 53 B ) Depth Of Excavation For Additional Depth Beyond 1500Mm And Upto 3000Mm. ( But Not Requiring Shoring ) . 54 Bailing Out Water From Foundation Trench. This Item Should Be Executed On The Specific Direction Of The Engineer-In-Charges When He Is Satisfied In His Absolute Discretion, That This Has Not Been Necessitated Due To Any Fault On The Part Of The Contractor ) 55 Hire And Labour Charges For Shoring Work ( Including Necessary Close Plank Walling, Framing, Eucalyptus / Jhau Balla Pilling, Strutting Etc ) Complete As Per Directionof The Engineer-In-Charge For Foundation Excavation ( Vertical Surface Are In Contact With Supported Earth Is To Be Measured. ) ( This Item Should Be Executed On Specific Direction Of The Engineer-In-Charge ) .A ) Depth Upto 1.5M. 56 B ) For Additional Depth Beyond 1.5M And Upto 3.00M. 57 Earth Filling In Foundation Trenches Or Plinth With Good Earth In Lyres Not Exceeding 150Mm Including Watering & Ramming Etc Layer By Layer Complete.A ) With Earth Obtained From Excavation Of Foundation. 58 Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm As Directed And Consolidating The Same By Thorough Saturation With Water, Ramming Complete Including The Cost Of Supply Of Sand. ( Payment To Be Made On Measurement Of Finished Quantity ) Do - By Fine Sand 59 Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming And Dressing Bed To Proper Level, And Filling Joints With Powered Earth Or Local Sand. 60 Cement Concrete With Graded Stone Chips ( 20Mm Size ) Excluding Shuttering, In Ground Floor ) Considering 30 Km Distance From Suri Rly. Yard.A ) 1:2:4 Proportion. ( In Foundation And Under Tank At Finished Gl, Plinth Protection Etc. ) 61 Controlled Cement Concrete With Well Graded Stone Chips ( 20Mm Nominal Size ) Excluding Shuttering & Reinforcement With Complete Design Of Concrete As Per I.S.456 And Relevant Special Publications, Submission Of Jobs Mix Formula After Preliminary Mix Design After Testing Of Concrete Cubes As Per Direction Of Eic. Consumption Of Cement Concrete Will Not Be Less Than 300Kg Of Cement With Super Plasticizer Per Cubic Meter Of Controlled Concrete But Actual Consumption Will Be Determined On The Basis Of Preliminary Test And Job Mix Formula. ( Using Concrete Mixture ) .Considering 60 Km Distance From Suri Rly. Yardm- 25 Grade ( With Pakur Variety. ) A ) For Works In Foundation, Basement And Upto Roof Of Ground Floor / Upto 4M. 62 B ) 1St Floor I.E. From Top Of 1St Bracing To Top Of 2Nd Bracing 63 C ) 2Nd Floor I.E. From Top Of 2Nd Bracing To Top Of 3Rd Bracing 64 D ) 3Rd Floor I.E. From Top Of 3Rd Bracing To Top Of 4Th Bracing 65 E ) 4Th Floor I.E. From Top Of 4Th Bracing To Top Of 5Th Bracing 66 F ) 5Th Floor I.E. From Top Of 5Th Bracing To Bottom Of Heal Beam 67 Controlled Cement Concrete With Well Graded Stone Chips ( 20Mm Nominal Size ) Excluding Shuttering & Reinforcement With Complete Design Of Concrete As Per I.S.456 And Relevant Special Publications, Submission Of Jobs Mix Formula After Preliminary Mix Design After Testing Of Concrete Cubes As Per Direction Of Eic. Consumption Of Cement Concrete Will Not Be Less Than 300Kg Of Cement With Super Plasticizer Per Cubic Meter Of Controlled Concrete But Actual Consumption Will Be Determined On The Basis Of Preliminary Test And Job Mix Formula. ( Using Concrete Mixture ) . Considering 60 Km Distance From Suri Rly. Yardm- 30 Grade ( With Pakur Variety. ) A ) Heal Beam And Above ( Cell Wall, Floor, Top & Bottom Ring Beam, Heal Beam ) A ) 6Th Floor 68 B ) 7Th Floor 69 Hire And Labour Charges For Shuttering With Centering And Necessary Staging Upto 4M Using Approved Stout Props And Thick Hard Wood Planks Of Approved Thickness And Required Bracing For Concrete Slabs, Beams, Column Lintel Curved Or Straight Including Fitting, Fixing And Striking Out After Completion Of Woks ( Upto Roof Of Ground Floor ) .Steel Shuttering Or 9 To 12Mm Thick Approved Quality Ply Board Shuttering In Any Concrete Work.C ) For Foundation Upto G.L. 70 Hire And Labour Charges For Shuttering For Concrete Work In Overhead R.C. Reservoir On Separate R.C. Frame Including Fitting, Fixing And Striking Off After Completion Of Work Including Staging Upto 4M Using Ply Board Or Steel Shuttering. ( Not Applicable For Resting On Roof Top ) .A ) G.L. To Top Lantern Of Ohr. 71 Hire And Labour Charges For Staging Beyond 4M With Necessary Cross Bracing And Fixtures And Removing The Same After Completion Of The Work All Complete As Per Direction Of The E.I.C. [ Mode Of Measurement :Area Of Unsupported Horizontal Projection ( Where Staging Beyond 4M Is Practically Un-Avoidable ) X Mean Height Of Staging ] Above Initial 4M. ( Dia 10.50 M. Mean Height 16M. ) 72 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc. , Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Inter-Section, Complete As Per Drawing And Direction. I ) Tor Steel / Mild Steeli. Sail / Tata / Rinl A ) For Works In Foundation Basement Upto Roof Of Ground Floor / Upto 4 M . 73 B ) 1St Floor I.E. From Top Of 1St Bracing To Top Of 2Nd Bracing 74 C ) 2Nd Floor I.E. From Top Of 2Nd Bracing To Top Of 3Rd Bracing 75 D ) 3Rd Floor I.E. From Top Of 3Rd Bracing To Top Of 4Th Bracing 76 E ) 4Th Floor I.E. From Top Of 4Th Bracing To Top Of 5Th Bracing 77 F ) 5Th Floor I.E. From Top Of 5Th Bracing To Top Of Heal Beam 78 G ) 6Th Floor I.E. From Top Of Heal Beam To Top Ofshell Wall 79 H ) 7Th Floori.E. From Top Of Shell Wall To Rest 80 Applying 2 ( Two ) Coats Of Bonding Agent With Synthetic Multi Funtional Rubber Emulsion Having Adhesive And Water Proofing Properties By Making With Water In Proportion ( 1 Bonding Agent : 4 Water : 6 Cement ) As Per ManufacturerS Specification. 81 Extra Rate For Using Water Proofing And Plastering Admixture @ 0.2%By Weight Of Cement ( Or At ManufacturerS Specified Rate For Concrete Of Various Grades ) . 82 Supplying, Fitting, Fixing Fly / Mosquito Proof Nylon Net On Any Type Of Window, Doorshutter Frame With Necessary Fixing Arrangements Complete. 83 Supplying Fitting And Fixing Door Made With Irc Febric Mesh Of 75Mm X50mmx4.5Mmx2.7Mm On 50Mm X 50Mm X 6Mm Angle Iron Frames All Round And One 37.5Mm X 6Mm M.S. Flat Bar Over The Netting All Round Welded To Angle Iron Frame And Providing Locking Arrangements If Necessary And With Two Coats Of Synthetic Enamel Paint ( Other Than Hi-Gloss ) Fitted And Fixed With Clamps Or Haskal Doomney Etc. Complete At The Lantern Of R.C.C. Over Head Reservoir. 84 Artificial Stone In Floor, Dado, Staircase Etc. With Cement Concrete ( 1:2:4 ) With Stone Chips, Laid In Panels As Directed With Topping Made With Ordinary Or White Cement ( As Necessary ) And Marble Dust In Proportion ( 1:2 ) Including Smooth Finishing And Rouding Off Corners And Including Raking Out Joints Or Roughening Of Concrete Surface Andapplication Of Cement Slurry Before Flooring Works, Using Cement @ 1.75 Kg / Sq.M. All Complete Including All Materials And Labour.In Ground Floor 3 Mm Thick Topping ( High ) Polishing, Grinding On This Item Is Not Permitted With Ordinary Cement ) .25 Mm Thick.A ) In G.F For Plinth Protection And Under Tank Floor 85 B ) 6Th Floor 86 C ) 7Th Floor 87 M.S. Structural Works In Columns, Beams Etc. With Simple Rolled Structural Members ( E.G. Joists, Angle, Channel Sections Conforming To Is: 226, Is: 808 & Sp ( 6 ) - 1964 Connected To One Another With Bracket, Gussets, Cleats As Per Design, Direction Of Engineer-In Charge Complete Including Cutting To Requisite Shape And Length, Fabrication With Necessary Bolting, Metal Arc Welding Conforming To Is: 816- 1969 & Is: 1995 Using Electrodes Of Approved Make And Brand Conforming To Is:814- 2004, Haulage, Hoisting And Erection All Complete. The Rate Includes The Cost Of Rolled Steel Section, Consumables Such As Electrodes, Gas And Hire Charge Of All Tools And Plants And Labour Required For The Work Including All Incidental Chages Such As Electricity Charges, Labour Insurance Charges Etc. Payment To Be Made On The Basis Of Calculated Weight Of Structural Members Only In Finished Work As Per Is Specified Weight. Payment For Gusset, Bracket, Cleat, Rivets, Bolts And Nuts May Be Make By Adding The Actual Weight Of Such Items With The Weight Of Finished Structural Members Or 7% Of Weight For Finished Structural Members Weighing Not Less Than 22.5 Kg. / M. Or 15 % Of Weight For Finished Structal Members Weighing Less Than 22.5 Kg. / M. May Be Increased Allow For Bracket, Cleat, Rivet, Bolts And Nuts Etc. And No Seperate Payment Being Made For These Items, As Per Direction Of Engineer In Charge. The Rates Are Considered For A Height Of Erection 8M. / 2Nd Floor Level From The Ground. Add 1.5% Extra Over The Rate For Each Additional Floor Or 4M. Beyond Initiial 8M. Or Part Thereof.Iii ) For Built Up Sections / Srtuctural Members Of Specified Sections Weighing Not Less Than 22.5 Kg. / M 88 M.S. Gate Of Jail Type As Per Approved Design Made Of Strong M.S. Frame Work, Intermediate Stiffeners And Round / Square Bars Or Angles. M.S. Sheet ( Not Less Than 14 Gauge ) Gussets, Cleats Etc. Including Necessary Riveting, Bolting, Welding, Locking And Hanging Arrangements, Fitting And Fixing Complete As Per Direction Of The Engineer-In -Charge. 89 M.S. Or W.I. Ornamental Grill Of Approved Design, Joints Continuously Welded With M.S. Wi Flats And Bats For Winding, Drilling Etc.Fitted & Fixedwith Necessary Screw And Lugs In Ground Floor.A ) Grill Weighing Above 10 Kg / Sqm Upto 16 Kg / Sqm ( In Kg ) 90 Supplying, Fitting, Fixing900 Mm High G.I. Pipe Railing For R.C.C Stair Cat Ladder Walk Way Fabrication, Erection, Welding Of 40 Mm G.I ( Non Tata Medium ) Pipe Place At Top Of Railingand2 Nos 25 Mm Dia. G.I Pipe ( Non Tata Medium ) Placed Equally In Between Railingtop & Floor, Vertical Post Of Raillingare 40 Mm Dia. G.I Pipe ( Non Tata Medium ) Placed At 900 Mm C / C . The Each End Of The Vertical Post Is Join By The 62 Mm ( 25 Mm X 6 Mm X 0.062 M Long ) Ms Flat And 150 Mm Length ( Propes Pipes ) Are Grouted In Concrete Base Of Stair, Walk Way Etc. All Complete With Supplying Of All Materials Including Hoisting Up To The Any Height Complete With 2 Coats Of Painting With Super Gloss ( Hi Gloss ) In Any Shade Except White And Black Over A Coat Of Primer Complete As Per Direction Of E.I.C.Analysis Of Rate Enclosed In Seperate Sheets. ( Analysis Rate ) 91 Supplying At Site Hoisting, Fitting, Fixing Erecting And Building In Position Where Necessary 450Mm.Wide Ladder As Per Design Consisting Of 2Nos. M.S.Plate Of 8Mm.Thick With Necessary Base Plate 60Mm Wide; And 16Mm.Dia M.S.Round Or Square Bar As Steeps Placed @ 300 C / C Including Fabrication, Welding Drilling Etc. As Per Drawing And Direction And Finished With Two Coats Of Synthetic Enamel Painting Over A Coat Of Red Lead Primer Etc. All Complete As Per ;Direction Of The Eic 92 Supplying Fitting And Fixing In Position C.I Manhole / Pit Cover With Rim.A ) Square.I ) 600 X 600Mm ( 50Kg.Approx ) . 93 Brick Work With 1St Class Brick In Cement Morter. ( 1:6 ) In Superstructure Ground Floor ( 1:6 ) 94 Plaster ( To Wall, Floor, Ceiling Etc ) With Sand Cement Mortar Including Rounding Off Or Chambering Corners As Directed And Raking Out Joints Including Throating Nosing And Drip Course Scafolding / Staging Where Necessary ( Ground Floor ) Excluding Cast At Shipping Over Concrete Surface. Ii ) With 1:4 Cement Mortar ( 10 Mm Thick Cement Plaster ) A ) G.L. To Top Of 1St Bracing 95 B ) 1St Floor I.E. From Top Of 1St Bracing To Top Of 2Nd Bracing 96 C ) 2Nd Floor I.E. From Top Of 2Nd Bracing To Top Of 3Rd Bracing 97 D ) 3Rd Floor I.E. From Top Of 3Rd Bracing To Top Of 4Th Bracing 98 E ) 4Th Floor I.E. From Top Of 4Th Bracing To Top Of 5Th Bracing 99 F ) 5Th Floor I.E. From Top Of 5Th Bracing To Bottom Of Heal Beam 100 G ) 6Th Floor I.E.From Bottom Of Heal Beam To Top Of Ring Beam 101 H ) 7Th Floori.E. From Ring Beam To Rest 102 Plaster ( To Wall, Floor, Ceiling Etc ) With Sand Cement Mortar Including Rounding Off Or Chambering Corners As Directed And Raking Out Joints Including Throating Nosing And Drip Course Scafolding / Staging Where Necessary ( Ground Floor ) Excluding Cast At Shipping Over Concrete Surface. Ii ) With 1:3 Cement Mortar ( 10 Mm Thick Cement Plaster ) A ) 6Th Floor 103 B ) 7Th Floor 104 Supplying & Installation Of Lighting Solid Conductor Rod Of Phosphorous-Bronze Size 2M X 12Mm On The Top Dome Of The Rcc Overhead Reservoir, Laying Lightning Conductor Of 65Mm X 8Mm G.I. ( Hot Deep ) Ms Flatruns From The Roof Upto Gl Along The Shell Wall And Colume Fitted With Necessary Rust Proof Clamps, Lying65mm X 8Mm G.I. ( Hot Deep ) Ms Flat Conductorfrom Gl To Bottom Of The Earthing Main Pipe 80Mm Dia. Tata ( M ) Fitted And Fixedand Connecting With The Main Earthing Gi Pipe Of 80Mm.Dia Tata ( M ) Of 2.50M To Be Used As Earthing Electrode Driven Down To At Least 3.0M Below Gl And Filling Up With Charcoal, Construction Of Masonry Chamber Making As Per Direction Of Eic & Necessary Arrangement For Testing The Same As Per Iee Rule. ( All Work To Be Done As Specification Of Pwd ( Elec. ) Schedule. ) 105 Provision For Embossing The Name And Capacity Of The Reservoir With ( 2:1 ) Raised Sand Cement Plaster With Letter Size 30Cm. X 20Cm. On The Outside Of Shell Wall Of The Reservoir Painted Complete As Per Direction Of Eic. 106 Protective And Decorative Acrylic Exterior Emulsion Paint Of Approved Quality, As Per Manufacturer’S Specification And As Per Direction Of Eic To Be Applied Over Acrylic Primer As Required. The Rate Includes Cost Of Material, Labour, Scaffolding And All Incidental Charges But Excluding The Cost Of Primer. ( Two Coats. ) I ) Super Protective 100% Acrylic Emulsion.A ) G.L. To Top Of 1St Bracing 107 B ) From Top Of 1St Bracing To Top Of 2Nd Bracing 108 C ) From Top Of 2Nd Bracing To Top Of 3Rd Bracing 109 D ) From Top Of 3Rd Bracing To Top Of 4Th Bracing 110 E ) From Top Of 4Th Bracing To Top Of 5Th Bracing 111 F ) From Top Of 5Th Bracing To Top Of Heal Beam 112 G ) From Top Of Heal Beam To Top Of 1 / 3Rd Of Shell Wall 113 H ) From 1 / 3Rd Of Shell Wall To Rest 114 Applying Exterior Grade Acrylic Primer Of Approved Quality And Brand On Plastered Or Concrete Surface Old Or New Surface To Received Decorative Textured ( Matt Finish ) Or Smooth Finish Acrylic Exterior Emulsion Paint Including Scraping And Preparing The Surface Thoroughly, Complete As Per Manufacturer’S Specification And As Per Direction Of The Eic. ( Two Coats ) A ) G.L. To Top Of 1St Bracing 115 B ) From Top Of 1St Bracing To Top Of 2Nd Bracing 116 C ) From Top Of 2Nd Bracing To Top Of 3Rd Bracing 117 D ) From Top Of 3Rd Bracing To Top Of 4Th Bracing 118 E ) From Top Of 4Th Bracing To Top Of 5Th Bracing 119 F ) From Top Of 5Th Bracing To Top Of Heal Beam 120 G ) From Top Of Heal Beam To Top Of 1 / 3Rd Of Shell Wall 121 H ) From 1 / 3Rd Of Shell Wall To Rest 122 Neat Cement Punning About 1.5Mm Thick In Wall, Dado, Window, Ceiling, Floor, Drain Etc. 123 Priming One Coat On Steel Or Other Metal Surface With Synthetic Oil Bound Primer Of Approved Quality Including Smoothing Surface By Sand Pepering Etc. 124 Painting With Best Quality Synthetic Enamel Paint Of Approved Make And Brand Including Smoothening Surface By Sand Papering Etc Including Using Of A Approved Putty Etc On The Surface If Necessaryon Steel Or Other Metal Surface ( With Other Than Hi Gloss Of Approved Quality ) . I ) 2 Coats ( With Any Shade Except White ) 125 Painting With Ready Mixed Black Japan Of Approved Make And Brand Including Smoothening Surface.Two Coats. 126 Making Arrangement For Showing The Water Tightness Test Of The Rcc Elevated Reservoir By Filling With Water Upto The Maximum Level Of The Tank To The Full Satisfaction Of Eic ( Arrangements Of Water, Its Carriage And Lifting To The Tank Including Necessary Pipes, Fitting, Pumping Machinery Etc. Are To Be Provided By The Contractor With His Own Cost. ( If Water Is Supplied By The Department Rate Shall Be Reduced As Per Prevailing Departmental Rate ) ) 127 Disinfection And Washing The Tank And Pipe Connections Including Cleaning The Inside Of The Etc. Complete. 128 Hoisting, Erection , Placing Connecting With Pipes And Specials Cidf Pipes, Specials ) Securing With Building Specials Providing Stays, Clamps As Required Including Cost Of Staging Platform For The Work Etc.All Complete In All Respects As Per Drawing And Direction Of Eic.A ) 250Mm.Dia . 129 B ) 150Mm.Dia . 130 C ) 100Mm.Dia . 131 Laying Of Cidf / D.I Pipes With Specials, Valves Etc. In Trenches Including Excavation In All Sorts Of Soil, Moorum, Soft Rock And Refilling The Trenches After Laying & Jointing Of Pipes Etc. All Complete As Per Specification And Direction Of Eic.A ) 250Mm.Dia . 132 B ) 150Mm.Dia . 133 C ) 100Mm.Dia . 134 Fitting, Fixing Duct-Foot Bend Including Construction Of Cement Concrete ( 4:2:1 ) Base With Stone Chips Ofapproved Grade & Quality & Including Excavation Of Earth Etc Complete In All Respect. ( Analysis Rate ) A ) 250Mm.Dia ( Base Size 450Mm X 450Mm X 600Mm Deep ) 135 B ) 150Mm.Dia ( Base Size 450Mm X 450Mm X 600Mm Deep ) 136 C ) 100Mm.Dia ( Base Size 450Mm X 450Mm X 600Mm Deep ) 137 Hoisting, Fitting, Fixing Of Ci Bell Mouth With Puddle Collar In Rcc Work As Per Drawing Specification Complete In All Respect.A ) 250Mm.Dia . 138 B ) 150Mm.Dia . 139 C ) 100Mm.Dia . 140 Construction Of Masonry Drain 300 Mm X 250 Mm Inner Section With 1St Class 250 Mm Th. Brick Work In Cement Mortar ( 1:4 ) Over A Layer Of Single Brick Flat Soling , Sand Filling 100Mm Th. And 100 Mm Th. Weak Cement Concrete ( 6:3:1 ) With Graded Stone Ballast Pakur Variety ( 40Mm Size ) Including Earth Work In Excavation, 15Mm Th. Cement Plaster ( 4:1 ) And Neat Cement Punning All Rounding The Drain Etc. All Complete As Per Approved Design , Drawing And Direction Of The Engineer In-Charge. ( Analysis Rate ) 141 Supply And Delivery Of Different Dia.Cidf Pipe ( Class - B ) I.S: 1538 - 1976 & Specials ( Class - B ) As Per Is: 1538 - 1993 With Latest Amendment Including Loading, Unloading & Stacking Properly For Connection Of Inlet, Outlet, Overflow And Washout Line Of Ohr As Per Departmental Drawing With Specified Dia. Inclusive Of All Incidental Charges If Any All Complete As Per Direction Of The E.I.C. ( Test Certificate From The Manufacturer And Guarantee Certificate Should Be Produced By The Agency ) 142 A ) Supply And Delivery Of Cidf Sluice Valve Pn-10 Of Different Dia Make With Cast Iron Double Flanged Non Rising Spindle Sluice Valve Generally Conforing To I:S 14846-2000 With Latest Amended If Any Having Body Door Dome / Bonnet And Cover Of Cast Iron Gr.- F.G. 200 ( Ref. Is-210 ) Spindle Of Is: 6603 Gr.- 12 / Cr. 13 Non-Magnetic, Nut And Seat Rings Are Gunmetal As Per Is: 1538 Part Iv & Vi Valves Are Suitable For Maximum Working Pressure Of 10Kg / Sq.Cm. ( Seat Test ) And Body Tested To 15Kg / Sq.Cm. ( Test Certificate From The Manufacturer As Well As Inspection Certificate From Third Party Inspection, Agency To Be Arranged By Their Own Cost And To Be Approved By E.I.C. ) N.B. The Above Item Should Be Procured From The Reputed Manufacturer Viz- Kalpana, Jupiter & Upadhaya Or Similar Approved Vender List. [ With Cap ] A ) 250Mm.Dia . 143 B ) 150Mm.Dia . 144 C ) 100Mm.Dia . 145 Construction Of R.C.C. Inlet & Overflow Chamber As Per Drawing Cast With Rcc Wallwithcement Concretenot Leaner Than 1:1.5:3 With Graded 20 Mm Down Pakur Variety Stone Chips And Reforcement Having Wall Thickness 125 Mm And Complete With Plastering 15Mm Th. ( 1:4 ) With Neat Cement Finishing And As Per Direction Of The E.I.C. ( Inner Size = 600 Mm X 600 Mm X 750 Mm ) ( Analysis Rate ) 146 Applyingwate Thinable Non-Toxic Acrylic Polymer Modified Paint Coating Or Equivalent Brand Of Approved Quality 2 ( Two ) Finished Coats Over 2 Coats Of Primer Of Same Brand To The Ceiling Of Roof Dome Including Supplying Supplying Requisite Coating Materials Cleaning Of The Substrant Properly To Make It Free From Dirt, Paint, Oil And Grease Sludge, Blisters, Fungus , Moss, And All Other Undesireble Particles Using Wire Brush , Sand Paper Etc. Including Mending Good All Damages All Complete As Per Direction Of The E.I.C. 147 Supplying Hoisting, Fitting Fixing Approved Type Water Level Indicator With Copper Float, Guide Pulley, Wire Boards Etc. As Per Standard Specification And Direction And Satisfaction Of Eic 148 Site Clearence By Removing All Unserviceablematerials, Debris Etc. All Complete As Per Direction Of E.I.C. 149 Construction Of 3 Nos Pump House And Boundary Wall With Land Development ( Annexure Iv ) Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Laterite Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete.Depth Of Excavation Not Exceeding 1, 500 Mm. 150 Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm. As Directed And Consolidating Same By Thorough Saturation With Water Ramming Complete, Including The Cost Of Supply Of Sand. 151 Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming Anddressing Bed To Proper Level And Filling Joints With Local Sand. 152 Ordinary Cement Concrete ( 1:2:4 ) With Graded Stone Chips ( 20 Mm Size ) Nominal Size Excluding Shuttering And Reinforcement , If Any In Ground Floor As Per Relevant Is Code. ( A ) Pakur Variety 153 Ordinary Cement Concrete ( Mix 1:1.5:3 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement If Any, In Ground Floor As Per Relevant Is Codes. Pakur Variety 154 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth, In Layers Not Exceeding 150 Mm. Including Watering And Ramming Etc. Layer By Layer Complete. ( Payment To Be Made On The Basis Of Measurement Of Finished Quantity Of Work ) ( A ) With Earth Obtained From Excavation Of Foundation. 155 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc. , Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Inter-Section, Complete As Per Drawing And Direction.A ) For Works In Foundation Basement Upto Roof Of Ground Floor / Upto 4 M . I ) Top Steel / Mild Steel [ I. Sail / Tata / Rinl=> Rs.-53241.00 / M; Ii. Other Than Sail / Tata / Rinl=> Rs.-51991.00 / Mt ] 156 Brick Work With 1St Class Brick In Cement Morter. ( 1:6 ) In Foundation And Plinth. 157 Brick Work With 1St Class Brick In Cement Morter. ( 1:6 ) In Superstructure Ground Floor ( 1:6 ) 158 125 Mm Thick Brickwork With 1St Class Bricks In Cement Mortar ( 1:4 ) In Ground Floor 159 Hire And Labour Charges For Shuttering With Centering And Necessary Staging Upto 4 Mtr Using Approved About Props And Thick Hard Wood Planks Of Approved Thickness With Required Bracing For Concrete Slabs , Beams, Columns, Lintels, Curved Or Straight Including Fitting, Fixing & Striking Out After Completion Of Works ( Upto Roof Of Ground Floor ) A ) 25 Mm To 30 Mm Thick Wooden Shuttering As Per Decision & Direction Of Engineer-In-Charge. 160 25 Mm Thick Damp Proof Course With Cement Concrete With Stone Chips ( 3:1.5:1 ) ) ( With Gradedstone Aggregates 10 Mm Normal Size ) And Paintingthe Top Surface With A Coat Of Bitumen Using 1.7 Kg Per Sq M Including Heating The Bitumen And Cost And Carriage Of All Materials Complete. 161 Plaster ( To Wall, Floor, Ceiling Etc ) With Sand & Cement Mortar Includgrounding Off Or Chamfering Corners As Directed A Ramming Out Joints Or Roughening Of Concretesurface By Chamfering Etc. Including Threading Noising And Drip Course Where Necessary. ( Ground Floor ) I ) With 1:6 Cement Mortar.20 Mm Thick Plaster 162 I ) With 1:6 Cement Mortar.15 Mm Thick Plaster 163 I ) With 1:4 Cement Mortar.10 Mm Thick Plaster 164 Supplying Fitting, Fixing- Openable Steel Windows As Per Is Sizes With Side Hung Shutters And Horizotal Glazing Bars With / Without Fixed Type Ventilators. [ The Extra Rate Admissible For The Openable Portion Only ] ( P-82, I-33 ) 165 Supplying 1.5Mm Thick M.S. Sheet Fitted And Fixed On One Or Both Faces Of M.S. / W.I. Gate Etc. With Point Welding At Not More Than150mm Apart Complete In All Respect As Per Design Including Cost Of All Labour And Materials 166 M.S. Or W.I. Ornamental Grill Of Approved Design, Joints Continuously Welded With M.S. Wi Flats And Bats For Winding, Drilling Etc.Fitted & Fixedwith Necessary Screw And Lugs In Ground Floor. ( I ) Grill Weighing Above 10 Kg. / Sq.Mtr And Up To 16 Kg. / Sq. Mtr.Rs.- 8247.00 / Qt, ( Ii ) Grill Weighing Above 16 Kg. / Sq.Mtr And Abovers.-8053.00 / Qt. 167 Applying Decorative Cement Based Paint Of Approved Quality After Preparing The Surface Including Scraping The Same Thoroughly ( Plastered Or Concrete Surface ) As Per ManufactureS Specification In Ground Floor. A ) Two Coats ( On New Cement Plaster Surface ) 168 White Washing Including Cleaning And Smoothening Surfacethoroughly.A ) 3 Coats. 169 B ) Priming One Coat On Steel Or Other Metal Surface With Synthetic Oil Bound Primer Of Approved Quality Including Smoothening Surfaces By Sand Papering Etc. 170 Painting With Best Quality Synthetic Enamel Paint Of Approved Make And Brand Including Smoothening Surface By Sand Papering Etc Including Using Of A Approved Putty Etc On The Surface If Necessaryb ) On Steel Or Other Metal Surface ( With Other Than Hi Gloss Of Approved Quality ) . I ) 2 Coats ( With Any Shade Except White ) ( Hi Gloss ) 171 Number Plaque Of Buildings ( Plaque Size Upto 225 Mm X 225Mm ) Made Of Cement Plaster ( 2:1 ) On Face Of Wall Or Plinth , With 50 Mm Size Letters P.H.E. And The Number Of The Structure Formed Thereon ( In Sunk Type ) Including Painting The Letters Complete As Per Direction. ( Cement = 1 Kg / No ) 172 Supplying, Fitting And Fixing PeetS Valve Fullway Gunmetal Standard Pattern Best Quality Of Approved Brandbearing I.S.I. Marking With Fittings . ( Tested To 21 Kg / Sq.Cm. ) ( For Water Lines Only ) .- 15 Mm. Dia. 173 Construction Of Septic Tank Of Different Capacities As Per Approved Drawing With 1St Class Brick Work In Cement Mortar ( 1:4 ) Including Two 560 Mm Dia. R.C.C. Manhole Cover ( Heavy Type ) Of Approved Make Supplied, Fitted And Fixed In The 100Mm Thick R.C.C ( 1:1.5:3 ) Top Slab With Necessary Fittings, 20Mm Thick Cement Plaster ( 4 : 1 ) With Neat Cement Finish To The Internal Surfaces And 15 Mm Thick Cement Plaster ( 4 : 1 ) To Outside Wall Upto 200 Mm Below G.L Floor Finished With 25 Mm Thick Grey Artificial Stone Over 100 Mm Thick R.C.C ( 1:1.5:3 ) Bottom Slab Including Supplying, Fitting And Fixing All Necessry Specials, Fittings, S.W. Tees, C.I. Foot Rest Etc. Including Excavation Earth In All Sorts Of Soil, Shoring, Bailing Out And Pumping Out Water As Necessary, Ramming, Dressing The Bed And Fefilling The Sides Of The Tanks With Earth, Removing Spoils, Filling Up The Chamber With Clear Water, Removing Foreign Materials From The Chamber And Including Constructing Attached Inspection Pit As Per Approved Drawing And Connecting All Necessary Pipes, Joints Etc. With Internal Plaster Work And Artificial Stone Flooring Is To Be Done With Admixture Of Water Proofing Compound @ 0.5% By Weight Of Cement With All Costs Of Labour And Materials. Note:- ( I ) Finished Level Of Septic Tank Should Be 400 Mm. From Ground Level. ( Ii ) Height Of 50 Mm. Ventilation Pipe &Mosquito Proof Mesh, Should Be Follwed As Per Is:2470, Part I.Payment Will Be Made Separetly On The Basis Of Actual Height Based On Relevant I.S.Code. ( I ) For 10 Usersa ) With Pakur Variety. ( Sail / Tata / Rinl ) 174 Supplying, Fitting & Fixing Orissa Pattern Water Closet In White Glazed Vitreous Chinaware Of Approved Make Supplied , Fitted Fixed In Positioncomplete Excluding P Or S Trap. ( Excluding Cost Of Concrete For Fitting ) I ) 530Mm X 410 Mm 175 Supplying Fitting And Fixing10 Litre Pvc Low-Down Cisternof Conforming To I.S. Specification With Pvc Fitting Complete C.I.Make With Either Side Or Bottom Brackets Including Two Coats Of Painting To Brackets. 176 Supplying Pvc Water Storage Tank Of Approved Quality With Closed Lid ( Black ) -Multilayer. A ) 500 Litre Capacity. 177 Construction Of Circular Soak Well 2.5 Metre Deep In All Types Of Sandy Soils With Dry Brick Work Upto 1.6 Metre From The Bottom Having 150 Mm Intermediate Cement Brick Work ( 1:4 ) Band All Round And Cement Brick Work ( 1:4 ) Upto 0.90 Metre From Top With 20Mm Thick Cement Plastering ( 1:4 ) To Inside Face Upto The Depth Of Cement Brick Work, 15Mm Thick Cement Plaster ( 1:4 ) On Outer Face From Top Of The Well Upto G.L. And 6 Mm Thick Cement Plaster ( 1:4 ) On Top Of The R.C.C. Cover Slab Including Filling Bottom 1.00 Metre Of Inside Of The Well With Brick Metal ( 50 Mm To 63 Mm Size ) Including R.C.C. Cover Slab Of 100 Mm Thick With Cement Conc ( 1:1.5:3 ) With Stone Chips With Necessary Reinforcement And Shuttering Including One 560 Mm Dia. R.C.C. Manhole Cover ( Heavy Type ) Of Approved Make Supplied, Fitted And Fixed In The Cover Slab With Necessary Fittings, Making Nacessary Arrangements For Pipe Connections, Excavation Of Well Including Shoring, Dewatering And Removing The Exess Earth From The Premises As Per Direction Complete In All Respect With All Costs Of Labour And Materials. With 250 Mm Thick Dry Brick Work And 250 Mm Thick Cement Brick Work ( 1:6 ) And 1.00M Inside Dia. ( Sail / Tata / Rinl ) 178 Supplying, Fitting & Fixing Upvc Pipes A-Type And Fittings Conforming To Is:13592-1992 With All Necessary Clamps Nails, Including Making Holes In Walls, Floor Etc. Cutting Trenches In Any Soil Through Masonry Concrete Structures Et. If Necessary And Mending Good Damages Including Joining With Jointing Materials ( Spun Yarn, Valamoid / Bitumen / M-Seal Etc ) Complete. ( A ) 75Mm. Dia. 179 Supplying, Fitting And Fixing Fan Hook For Ceiling With1 Metre Long16mm Dia Rod Complete Including Mending Damages .Payment For Damage And Repair To Be Made Separately. 180 Wash Basin White Vitreous China Of Approved Make ( Without Fittings ) Supplied , Fitted And Fixed In Position On 75Mm X 75Mm X 75Mm Wood Blocks And C.I. Brackets Including Two Coats Of Painting Of C.I. Brackets. ( A ) 450 Mm X 300 Mm Size. 181 Supplying, Fitting And Fixing Approved Brand P.V.C. Connector White Flexible, With Both Ends Coupling With Heavy Brass C.P. Nut, 15 Mm Dia. ( A ) 900 Mm Long. 182 Cutting Holes And Subsequent Mending Good Damages. 183 Supplying , Fitting And Fixing 30 Mm. Thick Both Side Prelaminated Factory Made Solid Panel Pvc Door Shutter Consisting Of Outer Frame Made Out Of Ms Tubes Of 19 Gauge Thickness And Size 19 Mm. X 19 Mm. For Styles, Top And Bottom Rails, Ms Frame Shalll Have Cost Of Steelprimers Of Approved Make And Manufacture, M.S Frame Cover With 5 Mm.Thick Head Moulded Pvc C Channel Of Size 30 Mm. Thick 70Mm. Width Out Of Which 50 Mm. Shall Beflat And 20Mm. Shall Be Tapered In 45 Degree Angle Of Either Side Forming Styles, And 5Mm Thick 95 Mm. Wide Pvc Sheet Out Of Which 75 Mm. Shall Be Flat And 20 Mm. Tapered In 45 Degree On The Inner Side Toform Top & Bottom Rail And 115Mm.Wide Pvc Sheet Out Of Which 75 Mm. Shall Be Flat And 20 Mm. Shall Be Tapered On Both Sides To Form Lock Rail. Top Bottom And Lock Rails Shall Be Provided Either Side Of The Panel With 10Mm. ( 5Mm. X 2 Mm. ) Thick , 20 Mm. Wide Cross Pvc Sheet As Gap Insert For Top Rail And Botttom Rail Sheet To Be Fitted In The M.S Frame Weled / Sealed Tothe Styles &Rails With 7 Mm. ( 5Mm. + 2 Mm. ) Thick X 15 Mm. Wide Pvc Sheet Beading On Inner Side And Joint Together With Solvent Cement Adhesive . An Additional 5 Mm. Thick Pvc Strip Of 20 Mm. Which Is To Be Stuck On The Interior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Com Excluding All Necessary Hardwire As Per Direction Of The E.I.C In Ground Floor. 184 Supplying Fitting Approved Type Ventilator In Position After Cutting Holes In Walls, Setting In Cement Mortar, Mending Damages To Wall And Plaster And Two Coats Of Paint Of Approved Brand Sand Shade .Payment Of Mending Two Damages Of Wall & Plaster And Painting To Be Made Separately.R.C.C. Ventilator Of 20 Mm Thick - Upto 0.10 Sq.M. Area 185 Constructing Inspection Pit Of Inside Measurement 600 Mm X 600 Mm X Upto 600 Mm ( Depth ) With 250 Mm Thick 1St Classbrick Work In Cement Mortar ( 1:4 ) On All Sides , Bottom Of The Pit Consisting Of 100 Mm Thick Cement Concrete ( 1:3:6 ) With Stone Chips Over A Layer Of Jhama Brick Flat Soling, 15 Mm Thick ( 1:4 ) Cement Plaster To Inside Walls And Outside Walls Upto Gl And 20 Mm Thick ( 1:4 ) Plaster To Bottom Of The Pit, Providing Necessary Invert With Cement Concrete ( 1:3:6 ) With Stone Chips As Per Direction, Neat Cement Finishing To Entire Internal Surfaces, Top Of The Pit Covered With 100 Mm Thick Rcc Slab ( 1:1.5:3 ) With Stone Chips And Necessary Reinforcements Upto 1% And Shuttering Including 6 Mm Thick Cement Plaster ( 1:4 ) In All External Surfaces Of The Slab And One 560 Mm Dia Rcc Manhole Cover Of Approved Make Supplied, Fitted And Fixed In The Slab With Necessary Fittings, Necessary Earth Work In Excavation In All Sorts Of Soil, Filling Sides Of The Pit With Earth And Removing Spoils After Work Complete In All Respects With All Costs Of Labour And Materials. -With Pakur Variety. 186 Supplying , Fitting And Fixing Cast Iron P Or S Trap Conforming To I.S. 3989 / 1970 And 1729 / 1964 Including Lead Caulked Joints And Painting Two Coats To The Exposed Surface. ( Painting To Be Paid Seperately ) .- S Trap - 100 Mm. 187 Supplying, Fitting And Fixing Alloy Iron With Brass Spindle Bib Cock / Stop Cock Of Approved Brand And Make, Spray Painted And Tested To 21 Kg Per Sq.Cm. - 15 Mm. Dia. 188 Supplying, Fitting And Fixing Approved Patent Vent Cowl I.C.I. Conforming To I.S.S And Painting Two Coats To The Exposed Surface With Approved Paint Complete. ( Payment Of Painting Will However Be Paid Seperately ) .- 100 Mm Dia. 189 Supplying, Fitting And Fixing Pillar Cock Of Approved Make. A ) I ) Cp Pillar Cock-15 Mm ( Equivalent To Code No-507 & Model - Tropical / Sumthing Special Of Essco Or Similar Brand ) . 190 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth In Layers Not Exceeding 150 Mm. Including Watering And Ramming Etc. Layer By Layer Complete. A ) With Carried Earth Arranged By The Contractor Within A Radius Of 3 Km. Including Cost Of Carried Earth. 191 Laying For Rising Main & Distribuition System With Fhtc ( Annexure V ) Carrying Ci / Di Pipes With Specials And Valves And Lowering Placing In Position And Laying Carefully Inside The Trenches In Proper Alignment And Gradient Etc.Including Earth Work Inexcavation Of Adequate Width As Per Specification Having Min. Clear Cover From Top Of Pipe Is 1.10Mtr. Below Existing Ground Level In Any Kind Of Soil Including Mixed With Boulder, Road Sub-Grade And Its Flank, But Excluding Moorum And Laterite And Stone Etc.Without Damaging The Exisiting Telephone / Electric Cableetc. ( Incaseof Damaged If Any Type Of Cable Line During Excecution , Necessary Damaged Charges As Applicable By The Respective Authority Will Beborne By The Agency In His Own Cost ) Preparing The Bottom Surface For Continuous Bedding Of Pipe Line And Laying Pipes, Fitting, Fixing Specials And Valves With Bailing Out Water If Any Including Carriage Of Pipes, Specials And Valves From Local Deptt.Store Within 8Km And Back Filling The Trenches With Excavated Earth In Layers To Original Condition As Per Specification And Direction Of Eic. The Surplus Materials After Execution Of Work Are To Be Return To The Deptt. Store.N.B: I ) Any Deviation From Required Clear Cover Of 1.10Mtr., Due To Site Adverse Condition, Prior Permission Is To Be Obtained From The Eic In Exceptional Situation And Payment Will Be Made On Prorate Basis Over The Rate Of Entire Item Ii ) No Payment Will Be Made Without Hydraulic Test Of The Pipe Line Either Part Or Full Iii ) Thepipes, Specials And Valves , Rubber Gasket Will Be Supplied Deptt. Free Of Cost.A ) 150Mm Dia. 192 B ) 200Mm Dia. 193 C ) 250Mm Dia 194 Making Rubber Gasket Joint To Ci / Di Pipes Maintaining Proper Alignment Level Etc. By Mechanical Arrangement With Or Without Using Mobile Cranes Where Necessary And With Help Of All Other Equipments Tools And Tackles Etc. As Required Providing Lubricants Of Approved Quality And Direction Of Eic. ( Rubber Gasket Will Be Supplied Deptt. Free Of Cost ) B ) 150Mm Dia. 195 C ) 200Mm Dia. 196 D ) 250Mm Dia 197 Making Flange Joint To Di / Ci Pipes, Specials And Valves Where Necessary With Supply Of Required Rubber Insertion And Nut Bolts, Washers Etc. Of Approved Quality And Type All Complete As Per Specification And Direction Of Eic ( Nut And Bolts Shall Be Of Tata / Gkw Rate ) .A ) 250Mm Dia 198 B ) 200Mm Dia. 199 C ) 150Mm Dia. 200 E ) 100Mm.Dia . 201 Cutting Di Pipe ( All Class & Type ) To Required Length With Cutting Device Etc. And Grinding The Cutting Portion With File As Per Direction And Satisfaction Of Eic.B ) 150Mm.Dia.To 200Mm.Dia Pipe 202 C ) 250Mm.Dia.To 350 Mm.Dia Pipe 203 Chamfering The Spigot End Of All Type / Class Of Di Pipe For Proper Using Of Push Joint By Means Of Grinder Set At Site For Proper Joint Etc. All Complete As Per Direction Of Eic.B ) 150Mm Dia. 204 C ) 200Mm Dia. 205 D ) 250Mm Dia 206 Filling The Pipe Line With Water, Testing Hydraulically As Per I.S 3114-1965 ( Article-6 ) In Section Of A Length Not Exceeding 500Mtr. For Head Of Pressure As Per Specification Including Supplying Installing And Fixing All Equipments Such As Diesel Pump Set, Blank Flange, Pressure Gauge, Valve, Pressure Pump And All Other Tools And Plants Including Drilling Topping And Plugging Of Necessary Holes To Pipes, Blocking Ends Providing Temporary Thrust Block And Subsequent Blocking Of Holes And Other Jointing Materials And Dismantling And Removal Of The Same Including Disposal Of Water Etc. All Complete As Per Specification And Direction Of Eic. The Rate Is Inclusive Of Cost Of Requisite Water To Be Arranged By The Contractor ( Recovery Rate Of Water @ Rs.10.00 / M3, If Contractor Used Water From Deptt. Source ) .A ) For Ci / Di Pipe.A ) 150Mm Dia. 207 B ) 200Mm Dia. 208 C ) 250Mm Dia 209 B ) For Upvc / Hdpe Pipea ) 50Mm ( Od ) 210 B ) 63Mm ( Od ) 211 C ) 75Mm ( Od ) 212 D ) 90Mm ( Od ) 213 E ) 110Mm ( Od ) 214 F ) 125Mm ( Od ) 215 G ) 140Mm ( Od ) 216 H ) 160Mm ( Od ) 217 I ) 180Mm ( Od ) 218 J ) 200Mm ( Od ) 219 K ) 225Mm ( Od ) 220 Cleaning Thoroughly The Inner Surface Of Pipe Line Including Specials And Valves By Flushing With Water And Subsequently Disinfection Of The Same Pipe Line By Flushing Again With Water Containing Bleaching Powder Resulting In Residual Chlorine Not Less Than 15Mg / Ltrs. After 24Hrs. Of Such Filling Including Laboratory Testing Of Water Samples Obtain From The Disinfested Pipe Line And Disposal Of Water From The Pipe Line After Completion Of The Work. The Rates Including Of Cost Of Requisite Water To Be Arranged By The Contractor ) ( The Rate Of Water @Rs. 10 / M3 May Be Recovered, If The Contractor Used Water From Deptt. Source ) .A ) For Ci / Di Pipe.B ) 150Mm Dia. 221 C ) 200Mm Dia. 222 D ) 250Mm Dia. 223 B ) For Upvc / Hdpe Pipea ) 50Mm ( Od ) 224 B ) 63Mm ( Od ) 225 C ) 75Mm ( Od ) 226 D ) 90Mm ( Od ) 227 E ) 110Mm ( Od ) 228 F ) 125Mm ( Od ) 229 G ) 140Mm ( Od ) 230 H ) 160Mm ( Od ) 231 I ) 180Mm ( Od ) 232 J ) 200Mm ( Od ) 233 K ) 225Mm ( Od ) 234 Submission Of Complete Detailed Drawing Of Distribution System, Rising Main Etc. After Execution Of Work Showing Position Of Different Types Of Valves, Fittings / Specials Sluice Valve Chamber With Location, Node To Node Wise In The Sanctioned Drawing As Completion Drawing Of The Water Supply Scheme As Per Direction And Satisfaction Of Eic. The List Of Dia Wise Fitting / Specials, Different Pipes ;Of Valve Used In The Rising Main Should Be Shown In The Completion Drawing ( Not Separate ) With Verified By Sae & Ae In-Charge Of The Scheme. The Above Drawing Will Be Submitted In 5 Copies. 235 Bituminous Pucca Road ( Approx. 450Mm Depth ) Cutting By Using Gaiti, Chisel, Hammer Etc. And Picking Uip The Withdrawing Excavated Materials And Remove The Same Within Distance Of 30Mtr. At Least All Complete For Fixing / Crossing All Dia Of Pipe Line As Per Direction Of Eic 236 Dismantling All Type Of Plain Cement Concrete Works, Stacking Serviceable Materials Of Site And Removing Rubbish As Directed Within A Lead Of 75Mtr. For Laying All Dia Pipe Line In Ground Floor, Upto 150Mm Thick.A ) Upto 150Mm Thick 237 B ) Above 150Mm Thick 238 Construction Of Different Dia Sluice Valve / Air Valve / Washout Chamber In Different Sizes For Village Road Where Light Traffic Run And For Main Road Where Heavy Traffic Run As Deptt.Approved Drawing With 25Cm Thick Brick Work ( 1:6 ) Over Cement Concrete ( 4:2:1 ) Over A Single B / F Soling Over150mm.Thick Sand Filling In Foundation Including Earth Work In Excavation And Disposal Of Excess Earth From Work Site With Rcc ( 1:1.5:3 ) Cover Slab 100Mm / 150Mm Thick Slab On Top Of Chamber With 1% Reinforcement Inrcc Cover Slab With Necessary Opening For Operation Of Valve All Complete Including Cost Of Labour & Materials As Per Departmental Dwg. [ Reinforcement Type:- Other Manufactuerers Not Specified ] I ) 80 Mm To 150 Mm Dia Pipe 239 Ii ) 200 Mm Dia Pipe 240 Iii ) 250 Mm Dia To 350Mm Dia Pipe 241 Making Holes In Two Sides Of Wall Of Culvert / Drain Or Any Other Structuresin Any Places For Laying Any Dia Pipe Line Within Structures Intwo Sides Of Wall Of Culvert / Drain / Any Structure At Any Places And Mending Good Damages All Complete As Per Direction Of Eic. 242 A ) Construction Of Rcc Street Stand Post ( 700Mm Height ) Of Rcc ( 1:1.5:3 ) Footing Over 75Mm Thick 4:2:1 P.C.C Over A Single B / F Soling With 1% Reinforcement, Connected With Saddlepiece & 15Mm Dia Brass Ferrule With Supplying Fitting, Fixing 15Mm Dia G.I. Nipple, G.I.Socket, G.I. 200Mm X 150Mm Reducing Elbow And 20Mm Dia Gi ( M ) Tata Pipe Of ( Avg. ) 2.6Mtr. Long And One 15Mm Dia Alloy Iron With Brass Spindle Bib Cock With Socket And 20Mm G.I. Elbow 2Nos. With 15Mm Gi ( M ) Tata Pipe Of 0.225Mtr. For Connection Of Stand Post To Distribution Line As Per Deptt. Design And Drawing As Per Direction Of Eic Along With Construction Of Platform Of Size Cc Platform ( 1:2:4 ) Over A Single B / F Soling Below G.L Over 150Mm.Thick Sand Filling, Neat Cement Finish Over Platform And Inner Side Of Band And 15Mm Thick Cement Plaster ( 4:1 ) On Top Of Platform Band And Outside Upto G.L. As Per Deptt. Drawing And As Per Direction Of Eic 243 Supplying Hdpe ( Materials Grade Pe-80 ) Pipes Conforming To Is 4984-1995 With Latest Revision & Amendments If Any With Necessary Hdpe Specials ( Excluding Cost Of Cidf Valves ) Including Labour Charges For Earth Work In Excavation In Any Kind Of Soil Including Mixed Soil With Boulder, Road Sub-Grade And Aits Flank But Excluding Moorum Laterite Or Sand Stone / Hard Rock Cutting With Chisel Required Including Cutting Road Flank / Brick Pavement Etc. Without Damaging The Exisiting Telephone / Electrical Cable Line Etc. ( In Case Of Damage Of Any Type Of Cable Line By The Agency At The Time Of Execution Necessary Damage Charge As Applicable By The Respective Authority Will Have To Be Brone By The Agency At His Own Cost ) Upto The Depth ( Av. ) So As To Maintain 1.10M.Earth Cushion From Top Of The Pipe Upto G.L. Including Loading Unloading Carrying Lowering Laying Fitting Fixing Carefully Pipes, Valves And Specials With The All Types Of Jointing Materials In Trenches Maintaining Proper Levels And Alignment Jointing The Pipes And Specials By Butt Welding / Adopting Suitable Method ( But Weld Jointing With Help Ofhydraulic Tack And Trimming Machines, Hitter Etc. For Reaching At Necessary Melting Point Of Hdpe Pipe So That Joint Can Be Monolithic ) So As To Facilitate The Maintenance Of Pipe Line Locally As Per Conventional Method In Future. ( A ) Pressure Rating : Pn 6Ii ) Laying Of Pipe Line Including Cost Of Pipe & Fittings / Specials Butexcluding Cost Of Valvesa ) 50Mm ( Od ) 244 B ) 63Mm ( Od ) 245 C ) 75Mm ( Od ) 246 D ) 90Mm ( Od ) 247 E ) 110Mm ( Od ) 248 F ) 125Mm ( Od ) 249 G ) 140Mm ( Od ) 250 H ) 160Mm ( Od ) 251 I ) 180Mm ( Od ) 252 J ) 200Mm ( Od ) 253 K ) 225Mm ( Od ) 254 Providing Fhtc From The Existing Cl / Dl / Upvc / Hdpe / Gl / Ac Distribution Pipeline By Installing 10 Mm Nb Gun-Metal Ferrule Conforming To Is 2692:1989 With Latest Amendments On The Said Pipeline With Supply, Fitting & Fixing Of All Other Accessories Like Saddle Piece Of Required Size To Fit The Existing Distribution Pipeline, Specials, Nut & Bolts, Rubber Sheet, Washers Etc And Supply & Laying Of 15Mm Nb Pvc ( Schedule 80 ) / 20Mm Od Hdpe ( Peioo, Pn16 ) Pipe ( Average 15M Length ) With All Necessary Specials 1.0 Metre Below The Ground Connecting The Ferrule Including Cutting Trenches In All Sorts Of Soil And Filling Up Trenches As Per Direction Of The Engineer-In-Charge And Upto A Point Just Inside The Premises Of The Household Or As Directed By Eic. Supply And Installation Of A 15Mm Dia. Alloy Iron Bib Cock ( Tested To 21 Kg / Cm2 ) Above 1.0 Mtr. From Ground, An Alloy Stop Cock Of 15 Mm Dia. With Brass Spindle ( Tested To 21 Kg / Cm2 ) To Be Fitted In A Position As Directed By E.I.C. G.L Pipe Of Tata Make ( Medium Duly ) Of 2 Metre Length With All Necessary Specials To Continue From The End Of The Hdpe / Pvc Pipe And Upto 1.0 M Above Ground Within The Premises Of Household.Note : 1. Pvc Pipe Shall Of Schedule 80 ( Medium Duty ) Conforming To Astmd-1785 And Threaded To Match With Gi Pipe As Per Is: 1239 ( Part-I ) .2. Rate Is Exclusive Of Supply And Delivery Of 10Mm Nb Gun Metal Ferrule.3. Payment Of Supply And Laying Of 15Mm Dia Nb Pvc ( Schedule 80 ) Or 20Mm Od Hdpe ( Pe 100, Pn 16 ) Pipe With All Necessary Specials 1.0M Below The Ground Will Be Made On Actual Measurement Basis. The Rate Of This Item Is Rs. 117 / -Per Metre.A ) Upto 10M Length 255 B ) Above 10M Upto 20M Length 256 Colection Of Household Details As Per Prescribed Formatthrough Mobile App / Hard Copies Including Geo Referance As Diected By E.I.C And Submission Of The Same To The P.H.E Dte.In Soft Copies. 257 Ordinary Cement Concrete ( Mix 1:2:4 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement, If Any, In Ground Floor As Per Relevant Is Codes.A ) Pakur Variety 258 Cost For Boring Any Type Of Soil By Augor Boring ( Horizontal ) With Water Jet System Including Hire Charges Of Machine, Tools & Plants, All Complete With All Labour And Supply Of Water Etc. As Per Specification And Direction Of Eic.I ) 80Mm To 100Mm Dia. 259 Ii ) 125 Mm To 200 Mm Dia 260 Supplying, Fitting And Fixing In Position G.I. Pipes Of Tata Make For Underground Works With All Necessary Accessories, Specials Viz.Socket, Bend, Tee, Union, Cross, Elbow, Nipple, Short Piece Etc.Including Cost Of All Materials, Jointing Materials , Cutting Pipes, Making Threads, Cutting Trenches Upto 1.5 Metre Below Surface In All Sorts Of Soil And Refilling The Same As Directed With Two Coats Of Painting On G.I. Pipes And Specials With Bituminous Paint Complete In All Respect. ( Payment Will Be Made On The Centre Line Measurement Of The Total Pipe Line Including All Specials No Separate Payment Will Be Made For Accessories, Specials.Payment For Painting Will Be Made Seperately ) ( S & P Schedule, Page-2 ) H ) ( Ii ) 80 Mm Dia. Medium Quality. 261 Supplying, Spreading And Consolidating Stone Dust To A Depth Of 100 Mm And Above At Desired Density And C.B.R. As Per Specification With Power Roller To Proper Gradient And Camber Including Watering As Necessary, And Lighting, Guarding, Barricading And Making Adequate Earthen Bundh Where Necessary To Protect The Edges And Curing With Water For 2 To 3 Days, Mending Cracks And Depressions By Rolling Where Necessary Including All Incidental Charges Of Roller, Cost Of Fuel & Lubricants Complete As Per Specification. ( Ref ; Pwd Sor 17 , Page No 242 , Item No 4.06 ) 262 Carriage Of Different Type Of Departmental Pipes From Divisional / Sub-Divisional Store To The Work Site By Truck Including Loading, Unloading, Stacking Etc. Including Cost Of Fuel, Lubricant And Also Cost Of Driver, Helper Etc. And All Other Taxes And Charges As Applicable As Per Direction Of Eicf ) Above 40 Km Upto 50 Km 263 G ) Above 50 Km ( Extra Cost Per Km ) Extra 50 Km ( 4 Nos Truck X 50 Km Each = 200 Km )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
21.
Communications and Information Technology  #10681581 Price Bid
Operation & Comprehensive Maintenance Of Electromechanical Services For Telephone Exchange, Jaysingpur , Comprehensive Maintenance And Round The Clock Operation Of Various Electromechanical Services As Per Details Given In Relevant Sections By Deploying The Required / By Automation Means Including Specialized Manpower And By Arranging Required Tools And Plant Etc To Keep All The Services Operational Upto The Required Standards Except Item Nos . 2 & 3 Below Which Shall Be Paid Extra As Per Running Hours Of Dg Sets . , A ) Services Included Are 1 ) Ei & Fans 2 ) Compound Lighting 3 ) Lightning Conductor 4 ) Pumps 5 ) 2 X 250 Kva ( 11 Kv Outdoor ) Substation 6 ) 1 X 100 Kva And 1 X 125 Kva Ea Sets 7 ) Fire Detection And Alarm System 8 ) 5 X 7 Tr Package Type A C Plant 9 ) Window / Split A / C Units 10 ) Fire Extinguishers , Contractors To Take All Steps To Undertake Preventive / Special Maintenance And Testing To Keep The System At Optimum Working Condition . Size Of Various Services Is Given In Section - I , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I / C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . , I ) 1 X 125 Kva Dg Set , Ii ) 1 X 100 Kva Dg Set , Supplying & Fixing Of Fully Charged 12 Volt , 180Ah Lead Acid Maintenance Free Battery For Starting Of 125 & 100 Kva E / A Sets Complete With End Sockets Etc . Note- 1 ) The Battery ( S ) Of Each Dg Set Shall Be Replaced ( Measurable Basis ) Once During Currency Of Contract & Agency Shall Consider Rebate For Old Battery While Quoting Of Rates . Additional Requirement To Be Borne By Agency Without Extra Cost .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
22.
Communications and Information Technology  #10681576 Price Bid
Operation & Comprehensive Maintenance Of Electromechanical Services For Wtr Earth Satellite Station Yeur ( Thane ) ., Comprehensive Maintenance And Round The Clock Operation Of Various Electromechanical Services As Per Details Given In Relevant Sections By Deploying The Required / By Automation Means Including Specialized Manpower And By Arranging Required Tools And Plant Etc To Keep All The Services Operational Upto The Required Standards Except Item Nos . 2 & 3 Below Which Shall Be Paid Extra As Per Running Hours Of Dg Sets . , A ) Services Included Are 1 ) Ei & Fans 2 ) Compound Lighting 3 ) Lightning Conductor 4 ) Pumps 5 ) 2 X 315 Kva ( 22 Kv Outdoor ) Substation 6 ) 2 X 125 Kva Ea Sets 7 ) Fire Detection And Alarm System 8 ) ( 3+1 ) X 10 Tr Package Type A C Plant 9 ) Window & Split A / C Units 10 ) Fire Extinguishers , Contractors To Take All Steps To Undertake Preventive / Special Maintenance And Testing To Keep The System At Optimum Working Condition . Size Of Various Services Is Given In Section - I , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I / C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . , I ) 2 X 125 Kva Dg Sets , Supplying & Fixing Of Fully Charged 12 Volt , 180Ah Lead Acid Maintenance Free Battery For Starting Of 125 Kva E / A Sets Complete With End Sockets Etc . Note- 1 ) The Battery ( S ) Of Each Dg Set Shall Be Replaced ( Measurable Basis ) Once During Currency Of Contract & Agency Shall Consider Rebate For Old Battery While Quoting Of Rates . Additional Requirement To Be Borne By Agency Without Extra Cost .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
23.
Communications and Information Technology  #10681549 Price Bid
Operation & Comprehensive Maintenance Of Electromechanical Services For Te Bldg. & S / Qtrs. At Chiplun , Comprehensive Maintenance And Round The Clock Operation Of Various Electromechanical Services As Per Details Given In Relevant Sections By Deploying The Required / By Automation Means Including Specialized Manpower And By Arranging Required Tools And Plant Etc To Keep All The Services Operational Upto The Required Standards Except Item Nos . 2 & 3 Below Which Shall Be Paid Extra As Per Running Hours Of Dg Sets . , A ) Services Included Are 1 ) Ei & Fans 2 ) Compound Lighting 3 ) Lightning Conductor 4 ) Pumps 5 ) 2 X 315 Kva ( 11 Kv Outdoor ) Substation 6 ) 1 X 200 Kva Ea Set 7 ) Fire Detection And Alarm System 8 ) 3 X 7 Tr Package Type A C Plant 9 ) Split A / C Units 10 ) Fire Extinguishers , Contractors To Take All Steps To Undertake Preventive / Special Maintenance And Testing To Keep The System At Optimum Working Condition . Size Of Various Services Is Given In Section - I , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I / C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . , I ) 1 X 200 Kva Dg Set , Supplying & Fixing Of Fully Charged 12 Volt , 180Ah Lead Acid Maintenance Free Battery For Starting Of 380 Kva E / A Sets Complete With End Sockets Etc . Note- 1 ) The Battery ( S ) Of Each Dg Set Shall Be Replaced ( Measurable Basis ) Once During Currency Of Contract & Agency Shall Consider Rebate For Old Battery While Quoting Of Rates . Additional Requirement To Be Borne By Agency Without Extra Cost .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Maharashtra View Result →
24.
Communications and Information Technology  #10670797 Price Bid
Operation & Comprehensive Maintenance of Electromechanical Services for TE Bldg. & Staff Quarters at Kalatalao Kalyan , comprehensive maintenance and round the clock operation of various electromechanical services as per details given in relevant sections by deploying the required staff including specialized manpower and by arranging required tools and plant etc to keep all the services operational upto the required standards except item nos . 2 & 3 below which shall be paid extra as per running hours of dg sets . , a ) services included are , 1 ) ei & fans , 2 ) compound lighting , 3 ) lightning conductor , 4 ) pumps , 5 ) 2 x 750 kva ( 22 kv indoor ) substation , 6 ) 2 x 500 kva & 1 x 750 kva e/a sets , 7 ) fire detection and alarm system , 8 ) 4 x 7 tr , 2 x 10 tr , 3 x 5 tr package type a c plant , 9 ) split ac units/air curtain , 10 ) 4 x 7 tr hpac unit plant , 11 ) fire extinguishers , contractors to take all steps to undertake preventive / special maintenance and testing to keep the system at optimum working condition . , size of various services is given in section - i , servicing & routine maintenance ( b check ) of following capacity of dg set complete with cleaning of air cleaner element , replacement of engine lube oil of proper grade ( seal pack of reputed make ) , replacement of lube oil filter elements , replacement of fuel filter elements , check & reset injector pressure , check & reset injector pump timing , retighten cylinder head nuts , adjust engine valve clearance , replacement of radiator water by fresh distilled water with addition of coolant additive concentrate , cleaning of radiator fins , drain sediments from water separator , check inlet air restriction , check air piping , belt tensions i/c cleaning & dedusting of alternator , control panel , fuel tank , tightening & maintaining of all hose connections , electrical connections , battery connections etc & actual load testing of dg set after servicing etc as directed . , i ) 1 x 750 kva dg set , ii ) 2 x 500 kva dg sets , supplying & fixing of fully charged 12 volt , 180ah lead acid maintenance free battery for starting of 750 & 500 kva e/a sets complete with end sockets etc . note- 1 ) the battery ( s ) of each dg set shall be replaced ( measurable basis ) once during currency of contract & agency shall consider rebate for old battery while quoting of rates . additional requirement to be borned by agency without extra cost .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
25.
Communications and Information Technology  #10667523 Price Bid
Operation & Comprehensive Maintenance Of Electromechanical Services For Te Bldg City Exch, Nasik ( Iii Rd Call ) . , Comprehensive Maintenance And Round The Clock Operation Of Various Electromechanical Services As Per Details Given In Relevant Sections By Deploying The Required Staff Including Specialized Manpower And By Arranging Required Tools And Plant Etc To Keep All The Services Operational Upto The Required Standards . ( Except Item 2 & 3 ) , A ) Services Included Are , 1 ) Ei & Fans , 2 ) Compound Lighting , 3 ) Lightning Conductor , 4 ) Pumps , 5 ) 2 X 315 ( 11 Kv ) I / D Substation , 6 ) 2 X 320 Kva E / A Sets , 7 ) Fire Detection And Alarm System , 8 ) Package Type A C Plants , 9 ) Fire Extinguishers , Contractors To Take All Steps To Undertake Preventive / Special Maintenance And Testing To Keep The System At Optimum Working Condition . Size Of Various Services Is Given In Section - I , Size Of Various Services Is Given In Section - I , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I / C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . , A ) 320 Kva Dg Set , Supplying & Fixing Of Fully Charged 12 Volt , 180Ah Lead Acid Maintenance Free Battery For Starting Of 250 Kva Dg Set Complete With End Sockets Etc Note- 1 ) The Battery ( S ) Of Each Dg Set Shall Be Replaced Once During Currency Of Contract & Agency Shall Consider Rebate For Old Battery While Quoting Of Rates )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
27.
Communications and Information Technology  #10627434 Price Bid
Cmc Of Window Split High Sensible And Package Type Air Conditioning Units Under Kolhapur Ssa , Comprehensive Maintenance Of Window / Split / High Sensible & Package Ac Units Of Following Capacity As Per The Terms And Conditions Enclosed . , Ac Units Completed Life Less Than 5 Years From The Date Of Commissioning , I ) Split Ac ( 1 . 5Tr ) , A ) 1St Year , B ) 2Nd Year , Ac Units Completed Life More Than 5 Years From The Date Of Commissioning , I ) Window Ac ( 1 . 5 Tr ) , A ) 1St Year , B ) 2Nd Year , Comprehensive Maintenance Of Air-Conditioning Units ( With Out Operation ) As Per Details Given In Relevant Sections By Deploying The Required Specialized Manpower As & When Required & By Arranging Required Tools And Plant Etc . To Carry Out Maintenance Activities And Attend All Break Down Maintenance Calls . , Contractors To Take All Steps To Undertake Preventive / Special Maintenance And Testing To Keep The System At Optimum Working Condition . , I ) Package Type Ac Unit - 5 . 0 Tr , A ) 1St Year , B ) 2Nd Year , Ii ) Package Type Ac Unit - 7 . 0 Tr , A ) 1St Year , B ) 2Nd Year , Iii ) Package Type Ac Unit - 10 . 0 Tr , A ) 1St Year , B ) 2Nd Year , Note: For Item Nos . 1[A] ( I ) , [B] ( I ) To ( Iv ) & 2 I ) To Iii ) The Agency Shall Maintain The Defect Free Services & Shall Submit Report While Raising The Due Payments . , Comprehensive Maintenance Of Ac Timer/ Twin Ac Stabiliser /Controller For Window / Split Ac Units As Per The Terms And Conditions Enclosed . ( Note:- Applicable For Inverter Type Split Ac Units ) , A ) 1St Year , B ) 2Nd Year , Sitc Of Pcb For Outdoor Unit Of 1 . 5 Tr Inverter Type Split Ac Unit I/C Removing Connections , Dismantling Of Existing Faulty Pcb , Making Connections Of New Pcb , T/C Etc . Complete As Reqd . ( Note:- Applicable For Inverter Type Split Ac Units In Ocm And Cmc Work )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
28.
Communications and Information Technology  #10613701 Price Bid
Tender For Ocm Of Ems At Telecom Compound Bhosari Pune , Comprehensive Maintenance And Round The Clock Operation Of Various Electromechanical Services As Per Details Given In Relevant Sections By Deploying The Required / By Automation Means Including Specialized Manpower And By Arranging Required Tools And Plant Etc To Keep All The Services Operational Upto The Required Standards Except Item Nos . 2 & 3 Below Which Shall Be Paid Extra As Per Running Hours Of Dg Sets . , A ) Services Included Are 1 ) Ei & Fans 2 ) Compound Lighting 3 ) Lightning Conductor 4 ) Pumps 5 ) 2 X 250 Kva ( 22 Kv Outdoor ) Substation 6 ) 2 X 250 Kva Ea Sets 7 ) Fire Detection And Alarm System 8 ) 6 X 7 Tr Package Type A C Plant 9 ) Split A / C Units 10 ) Fire Extinguishers , Contractors To Take All Steps To Undertake Preventive / Special Maintenance And Testing To Keep The System At Optimum Working Condition . Size Of Various Services Is Given In Section - I , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I / C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . , I ) 2 X 250 Kva Dg Sets , Supplying & Fixing Of Fully Charged 12 Volt , 180Ah Lead Acid Maintenance Free Battery For Starting Of 250 Kva E / A Sets Complete With End Sockets Etc . Note- 1 ) The Battery ( S ) Of Each Dg Set Shall Be Replaced ( Measurable Basis ) Once During Currency Of Contract & Agency Shall Consider Rebate For Old Battery While Quoting Of Rates . Additional Requirement To Be Borne By Agency Without Extra Cost .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
29.
Communications and Information Technology  #10613697 Price Bid
Operation & Comprehensive Maintenance Of Electromechanical Services For Telephone Exchange, Powai Naka, Satara , Comprehensive Maintenance And Round The Clock Operation Of Various Electromechanical Services As Per Details Given In Relevant Sections By Deploying The Required / By Automation Means Including Specialized Manpower And By Arranging Required Tools And Plant Etc To Keep All The Services Operational Upto The Required Standards Except Item Nos . 2 & 3 Below Which Shall Be Paid Extra As Per Running Hours Of Dg Sets . , A ) Services Included Are 1 ) Ei & Fans 2 ) Compound Lighting 3 ) Lightning Conductor 4 ) Pumps 5 ) 2 X 400 Kva ( 22 Kv Indoor ) Substation 6 ) 2 X 380 Kva Ea Sets 7 ) Fire Detection And Alarm System 8 ) 3 X 7 Tr Package Type A C Plant 9 ) Window / Split A / C Units 10 ) Fire Extinguishers , Contractors To Take All Steps To Undertake Preventive / Special Maintenance And Testing To Keep The System At Optimum Working Condition . Size Of Various Services Is Given In Section - I , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I / C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . , I ) 2 X 380 Kva Dg Sets , Supplying & Fixing Of Fully Charged 12 Volt , 180Ah Lead Acid Maintenance Free Battery For Starting Of 380 Kva E / A Sets Complete With End Sockets Etc . Note- 1 ) The Battery ( S ) Of Each Dg Set Shall Be Replaced ( Measurable Basis ) Once During Currency Of Contract & Agency Shall Consider Rebate For Old Battery While Quoting Of Rates . Additional Requirement To Be Borne By Agency Without Extra Cost .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
30.
Communications and Information Technology  #10613690 Price Bid
Operation & Comprehensive Maintenance Of Electromechanical Services For Telephone Exchange, Gandhinagar , Comprehensive Maintenance And Round The Clock Operation Of Various Electromechanical Services As Per Details Given In Relevant Sections By Deploying The Required / By Automation Means Including Specialized Manpower And By Arranging Required Tools And Plant Etc To Keep All The Services Operational Upto The Required Standards Except Item Nos . 2 & 3 Below Which Shall Be Paid Extra As Per Running Hours Of Dg Sets . , A ) Services Included Are 1 ) Ei & Fans 2 ) Compound Lighting 3 ) Lightning Conductor 4 ) Pumps 5 ) 2 X 160 Kva ( 11 Kv Outdoor ) Substation 6 ) 1 X 100 Kva And 1 X 125 Kva Ea Sets 7 ) Fire Detection And Alarm System 8 ) 5 X 7 Tr Package Type A C Plant 9 ) Window / Split A / C Units 10 ) Fire Extinguishers , Contractors To Take All Steps To Undertake Preventive / Special Maintenance And Testing To Keep The System At Optimum Working Condition . Size Of Various Services Is Given In Section - I , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I / C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . , I ) 1 X 125 Kva Dg Set , Ii ) 1 X 100 Kva Dg Set , Supplying & Fixing Of Fully Charged 12 Volt , 180Ah Lead Acid Maintenance Free Battery For Starting Of 125 & 100 Kva E / A Sets Complete With End Sockets Etc . Note- 1 ) The Battery ( S ) Of Each Dg Set Shall Be Replaced ( Measurable Basis ) Once During Currency Of Contract & Agency Shall Consider Rebate For Old Battery While Quoting Of Rates . Additional Requirement To Be Borne By Agency Without Extra Cost .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
31.
Housing Urban and Rular Development #10563534 Price Bid
annual repair and maintenance of Non-residential building, ITI, Jahangir Puri, Delhi during 2025-26- 1 Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size) 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand(zone-III) : 10 graded stone aggregate 40 mm nominal size) 4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 5 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 6 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm) with necessary accessories and screws etc. complete. 7 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 8 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. (a) Using M.S. angels 40x40x6 mm for diagonal braces. 9 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 10 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) 11 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 12 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 13 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : (a)With cement mortar 1:4 (1 cement : 4 coarse sand). 14 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains, septic tank and the like. 15 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat 16 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 17 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (a) One or more coats on old work. 18 Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface 19 Cleaning of terrace/loft water storage tank(inside surface area) upto 2000 litre capacity at all heights with coconut brushes,duster etc. removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking tha date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-charge. (The old date already written on tank should be removedwith paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) 20 Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consistfollowing operations:(i)Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and otherdeposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. 21 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 22 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 23 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 24 Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fitting and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. 25 Providing and fixing white vitreous china water closet squatting pan (Indian type) (a) Orissa pattern W.C. pan of size 580x440 mm 26 Providing and fixing 8 mm dia C.P. / S.S jet with flexible tube upto 1 metre long with S.S triangular plate to European type W.C. of quality and make as approved by Engineer-in-charge. 27 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.: (a)10 litre capacity - White 28 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm or 340x410x265mm sizes respectively. 29 Providing and fixing soil, waste and vent pipes : 100 mm dia. Sand cast iron S&S pipe as per IS: 1729. 30 Providing and fixing plain bend of required degree. 100 mm Sand cast iron S&S as per IS - 1729 31 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand Cast Iron S&S as per IS: 1729. 32 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes 33 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. (a) 25 mm dia. nominal bore 34 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 40 mm dia. nominal bore 35 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore 36 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore 37 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) (a) 20 mm nominal bore 38 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) (a) 25 mm nominal bore 39 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) (a) 40 mm nominal bore 40 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (a) Circular tank 41 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 250 to 300 mm diameter 42 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) 43 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) 44 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (a) With float glass panes of 5.50 mm thickness 45 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (a) With stainless steel cover plate minimum 1.25 mm thickness. 46 Modified Estimated Cost after using Correction factor on DSR 2023 on account of GST 0.973:- 47 Add 3% Cost Index : 48 Cleaning, filling, spreading & leveling stone boulders/Gravels/coarse Sand of allsize range , in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.( Material to be provided by department) 49 Uprooting plants from wall /toe by removing roots and stem after dismantling plaster and brick work/cement concrete of size 30x30x23 cm and after injection grouting with chemical graoxene/2 , 4- Dichlorophenoxycetic acid , repairing the damaged brick work in cement mortar of mix 1:4/ cement concrete 1:2:4 complete , as per direction of Engineer- in -Charge. 50 Cleaning of road gully grating chamber/gully trap chamber of all sizes & depth, removing of silt and disposal of sludge/sewer silt to near by pit & levelled up as per direction of enginee-in-charge. 51 Cleaning of man holes of size upto 900mmx1200mm and depth upto 1500mm including removing of silt, sludge, carriage & disposal to the required place, including all necessary precautionary measures by the contractor as per direction of engineer-in-charge. 52 Cleaning of sewer line with presure jet machine with manholes in depth beyond 90 cm to 180 cmi/c taking out debris, silt etc. & desilting & cleaing of M.H. completely. Washed with water jet presure disposal of collectec silt debries etc. to the MCD dumping ground all complete as per direction of Engineer in charge. All necessary safty measures shall be taken by agency during operation at his own cost & he will be responsible for any lapses. 53 Providing and applying white cement based putty of average thickness 0.5 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 54 Providing & fixing 3mm thick translucent white acrylic plastic sheet in steel/wooden window, ventilators shutters etc. by M-seal putty and nails wherever reqiured instead of glass panes complete as per direction in engineer- in- charge. 55 Lift of spreading stone/gravel from RWh recharge pit of all depth and stacking ofmaterial after separating them into different sizes, as per direction of Engineer-in-charge. Stone/gravel of all sizes 56 Maintenance and up keeping of all internal & external assets of ITI buildings complete. All Sundries items etc. are to be arrange by the contractor, labour, T&P (required for Mason, Carpenter, Plumber, Sewerman) etc. as required on all days. The day to day maintenance under this item shall include the following operations : (The material shall be arranged by department separately) Maintenance of sewerage, drainage system and desiliting of gully traps, manholes etc. within the campus like opening / cleaning of chocked sewer pipes, drains, manholes, gully traps etc. at all floors and vertical stacks of sewer pipes and rain water pipes of all sizes including thorough cleaning once of all soil waste and rain water pipes, drains, manholes, gully traps etc. on regular basis to keep sewerage & drainage system to make functional including disposal of silt, malba, waste, garbage etc. to the authorized dumping ground complete to the entire satisfaction and as per the directions of Engineer-in-Charge. Maintenance and cleaning of chajjas, roofs, areas below and around the water storage tanks, expansion joints, etc. and removing of cobwebs, beehives, vegetation, shrubs, small trees with roots including cutting and restoration of brick wall/roof/RCC and finishing the same to the original finish, disposal of silt, vegetations malba etc. to the authorized dumping ground to the entire satisfaction and as per directions of the engineer-in-Charge.Maintenance and operation of water supply grid system i/c grid and valves also including unfiltered water lines to keep the water supply system efficient and operational at all times complete to the entire satisfaction and as per directions of the Engineer-in-charges. Maintenance, repairing and fixing of existing damaged doors, windows, ventilators of steel, wood, PVC, pannelled, panalled and glazed, flush door etc. at all floors and heights including fixing of all necessary fittings, pannelling, glazing, replacement of damaged G.I. wiremesh in windows/doors including Painting etc. complete wherever required to keep them in proper functional conditions to the entire satisfaction and as per direction of Engineer-in-charge.Maintenance and repair of plumbing system for the entire campus i/c stopping leakages or over flow of water from PVC/RCC overhead tanks and , water closet cisterns and replacement of damaged G.I. pipes and fittings of all dia (internal and external), all fittings of PYC/PTMT/Brass/CP Brass for bib cocks, stop cocks, pillar cocks, angle valves, valve cocks/float ball & PVC tank cover for all capacities etc. to keep the entire water supply system efficient and functional to the entire satisfaction and as per directions of Engineer-in-charge. Maintenance and repair of internal and external plaster, ceiling plaster, pointing, flooring masonry work, leakages from roof, C.C. Gola, RCC work wherever required i/c dismantling to the entire satisfaction and as per directions of Engineer-in-charge. Welding by three/single phase electric welding machine i/cwelding rods etc. transportation to site at all floors with generator to weld broken grills, hinges, doors, windows, gates, railings, security doors and M.S. Sheet Garage door etc. excluding cost of material and fitting matching with existing one and any other steel work of class rooms offices, parks, boundary walls etc. to make functional complete in all respect and as per directions of Engineer-in-charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
32.
Drinking Water Supply and Sanitation #10562597 Price Bid
Tender For Water Supply Scheme For Augmentation Of Uwss Kushalgarh District Banswara Including 05 Years Om After 01 Year Of Defect Liability Period Under Amrut 2, Water Supply Scheme for Augmentation of UWSS Kushalgarh, District Banswara including 05 years O&M after 01 year of Defect Liability Period under AMRUT 2.0 Sl. No. Item Description 1 Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item andshall not be paid separately. 2 100 mm 3 150 mm 4 200 mm 5 Providing, lowering, laying and jointing in trenches, standardlengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing,disinfection, commissioning etc. complete as per technicalspecifications and direction of Engineer-in-charge of following classand diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing,design and layout are inclusive in RM measurement of the item andshall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 6 HDPE PE-100PN-6 7 90 mm 8 Fabrication, supply of flanged/ plain ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete (excluding flanged jointing wherever required) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer.Note : E/w to be measured and paid separately. 9 MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet) 10 Providing Household Tap Connection as per technical specification andapproved drawing as per relevant IS code (amended up to date) fromHDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premisesby using PP mechanical Integrated saddle with inbuilt flow controlvalve made out of SS316 designed for 5 LPM discharge at 0.5 barpressure , not exceeding the flow of 7 LPM at 2 bar and acompression elbow, moulded in single piece/ fusion welded(Complete job) including digging out suitable size of pits and trench forlaying service line in all kinds of soil; depositing and refilling of pit &jhiri with watering & ramming /compacting in layers and disposal ofsurplus excavated soil as directed with in a lead of 100 meter ;providing & fixing of all fitting duly approved in accordance withspecification for potable water including GM Full-way Valve (IS:778Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipePE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Threelayered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and aboveground level using PPR-C pipe with standard PPR fittings/ GI pipes inthe premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe linecomplete required for making of service connection complete in allrespect including labour charges . The service line should be laid atleast 45 cm below ground level.Note: Road cut and restoration is not part of this item and paidseparately. 11 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. 12 Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CCM-30 grade as per specification and direction of Engineer in charge.. 13 Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 14 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 15 3 core 16.0 Sq.mm 16 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade withaluminium conductor Armoured of IS:7098-I/1554-1 approved make in groundas per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thickunder layer of sand, second Class bricks covering, refilling earth, compactionof earth, making necessary connection, testing etc. as required of size. 17 Armoured Cable16.0 Sq. mm 4 core 18 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I.B class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance asrequired. 19 Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B class),Steel tube as per IS:1239 or amended up to date and zinc coating as per IS4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer &nut bolts etc. complete in all respect. 20 65 mm dia 21 Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type).k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 22 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 18 M 23 400 KL 24 Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soll fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per 1.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.h) Providing and fixing SS-304 ventilator, 55 304 manhole frame and cover and 55 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab.j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 25 Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 26 150 KL 27 Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required suchas duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope ofwork. 28 For OHSR 29 100 mm 30 200 mm 31 Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required suchas duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope ofwork. 32 For OHSR 33 200 mm 34 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipeline including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth includingconsolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 35 In All Typeof Soil 36 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming ofbottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth includingconsolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required . 37 Ordinary rock 38 Hard rock(blasting prohibited) 39 Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CCcutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 40 Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 50 metres as directed by Engineer. 41 Bituminous courses 42 Granular courses 43 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting,guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work. 44 Providingand laying in position cementconcrete in specified gradeover prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line andchamberwork.MeasurementforCCworktobemade asperstandard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 45 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 46 Providing, installation, testing and commissioning of Centrifugal Monoblockpump set conforming to IS 9079 , 2 pole motor operating at synchronisedspeed of 3000 RPM with requisite MOC impeller, priming funnel, cock,suitable flanges at suction and delivery side. Pump shall have common shaftfor pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall besuitable for working at various discharge and head requirements as perscope of work. Pump shall be erected on C.C. foundation / cross channels /RSJ frame block with suitable foundation bolts grouted in C.C. foundationblock etc. complete in all respect as per specification, scope of work anddirection of Engineer in Charge of following power rating, suitable forprescribed duty conditions mentioned in TD. 47 Centrifugal Monoblock Pump set (Single Stage) 48 11.0 KW (15 HP) 49 Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and 2 pole motor operating atsynchronised speed of speed 3000 RPM, with water proof winding. Pumpshall be suitable for various delivery head and discharge with stainless steelshaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and withwater lubricated bearing to accept entire hydraulic thrust. Supply, with cableguard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. Thepump set shall be suitable for direct coupling, with suitable suction strainer.Pump should have suitable discharge out let as per manufacturers design.Antithrust stream lined non return valve shall be provided with the pumpand minimum 6 m submersible copper conductor cable in single / doublerun and 2 pairs of suitable size erection clamp 10 mm thick shall be providedwith each pump etc. complete in all respect as per specification, scope ofwork and direction of Engineer in Charge of following posion : Less than 1.6mm Variation in thickness: Less than 3.2 mm) 50 submersibleMonoblock Pump set (Single Stage) 51 15.0 KW (20.0 HP) 52 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 53 Manually Operated CI Sluice valve of Class PN-1.0 54 100 mm HW 55 200 mm HW 56 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedup to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float GuideHBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material,labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 57 Class PN 1.0 58 40 mm 59 50 mm 60 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 61 Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 62 100 mm 63 150 mm 64 200 mm 65 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 66 100 mm dia. 67 150 mm dia. 68 200 mm dia. 69 SITCSTAR DELTA Starter type LT Panel of followingrating:all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated withangleframeincludingotherancillaries(Insulators, AcrylicSheet , Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge. 70 STAR DELTA STARTER 11.0 KW (15.0 HP)- :For 2 motors (1 W+ 1S)I/C -MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0- 500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) andO/G-MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 25A TP AC3 Duty(2),2NO+2NCAux.Block(2),ThermalOverloadRelay(9-13A)(2),Control MCB6ASP10KACCurve(2),SinglePhasePreventer(2),Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2) 71 STARDELTASTARTER 15.0KW (20.0HP) : For2motors(1W+ 1S)I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter96*96mm(0-500V)(1),VoltSelectorSwitch(1),Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue-1)(1),ControlMCB6ASP10KACCurve(3) andO/G-MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve (2),SinglePhasePreventer(2),IndicatingLights(Red-1,Green-1,Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/DTimer(2) 72 Construction of boundary wall of Brick/ stone masonry as per enclosed GAdrawing, scope of work and technical specifications complete work in allrespect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonry in CM: 1:6 section of foundation above PCC, 600mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)4. Superstructure work: Stone masonry in CM: 1:6, W-300, height-1650mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonry and cement mortar plaster20 mm thick on brick masonry in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall beprovided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. 73 Providing and fixing steel, gate, grating and grills made of angles, tees,square bars, flats or black pipe with hold fast and fitting complete as perdesign and drawing including cutting welding and fabrication with primingcoat of red oxide and two coat of enamel paints. 74 Construction of Pump house of RCC framed structure with pump pit in RCCwalls as per scope of work and technical specification complete work in allrespect including electrical works for indoor and outdoor lighting and fans,rain water drainage, sanitary, plumbing, monorail/ EOT crane etc. completeas per direction of Engineer-in-charge. The GA, structure, electrical,sanitary, P&ID, SLD to be prepared by the contractor and submitted todepartment for approval for earth quake zone II. 75 Pump House with Monorail arrangement 76 ConstructionofRCCSluicevalvechamberfordifferenttypeofvalves includingearthworkexcavation,100mmPCCM15 aslevellingcourse, RCC M25 grade for base slab, side wall & cover slab , including cost of steelreinforcement,formwork,Pre-castslabs,plasticencapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as per direction of Engineer-in-Charge. 77 For Class-A loading 78 Sluice valve chamber of size1.13m x0.85m x1.27mfor pipe size-upto100mm 79 Sluice valve chamber of size1.17m x0.95m x1.415mfor pipe size-from 125-to-150mm 80 Sluice valve chamber of size1.26m x1.185m x1.82mfor pipe size-from 200-to-300mm 81 Construction of RCC Air valve chamber for different type of valvesincluding earthwork excavation, 100mm PCC M15 as levelling course,RCC M25 grade for base slab, side wall & cover slab , including cost ofsteel reinforcement , form work, Pre-cast slabs, Plastic encapsulatedCI/MS Foot Rest, MS flats for the support of pre-cast, proper curing ofconcrete work complete in all respect as per specifications andstandard drawings and as per direction of Engineer-in-Charge. 82 Air valve chamber of size0.9m x1m x1.695mfor air valve size-from 50 mm-to-80mm 83 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines andspecificationscomplete: Media:Water(Clear),Temp.50deg.,Pr. rating:PN16,Protectiontype:IP-68, BodyMaterial:IS-210Gr.FG-200, AccuracyClass:ClassB(±2%@Nominalflowrate),MagneticDrive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In- Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 84 BFM 200 mm 85 Design, construction, commissioning & testing of Non Mechanical RapidGravity Filter Plant of capacity as under. This work includes constructionof RCC receiving chamber, baffle channel, flocculate, clarifier, collectingchannel, filter beds , operation gallery, clear water chamber, channel,chlorination chamber, Back wash tank, pipe system for carrying rawwater from Pump House to inlet of RGF, clear water from Plant to CWR,De-sludging system including providing pipe system from clarifier ,flocculate & back wash water chamber to existing storage tank, overhead back wash tank, back wash pumps (1W+1S) set with piping system,air blowers (1W+1S) as per design, interconnection of raw water, clearwater, sludge pipes etc. including allied works such for construction,commissioning of system as defined in scope of work, technicalspecifications and provisions of CPHEEO manual at various water supplyschemes 86 Up to 40 KLH capacity 87 Providing, laying, spreading and compacting of granular sub-base by providing close graded Material, mixing in a mechanical mix plant atOMC, carriage of mixed Material to work site, spreading in uniformlayers with motor grader on prepared surface and compacting withvibratory power roller to achieve the desired density, complete asper MoRT&H specification clause - 401 including all material, labour,machinery, lighting, guarding and maintenance of diversion.Grading - I Material 88 Providing, laying, spreading (with paver finisher only) andcompacting wet mix macadam (WMM) base course comprising ofgraded stone aggregate and granular material conforming toMORT&H specifications (Table 400-II) in layers of equal compactedthickness each consolidated, including pre-mixing the material withwater at OMC in mechanical mixer (Pug Mill), carriage of mixedmaterial by tippers to site, laying in uniform layers in base course ona well prepared sub-base/ base course and compacting with powervibratory-roller to achieve the desired density complete as perMoRT&H specification clause - 406 including all material, labour,machinery, lighting, guarding and maintenance of diversion. 89 Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS : 8887 and approved quality @ 0.6 kg/sqm with the help of spray set fitted on bitumen Container (boiler) after cleaning the surface including removing of binding material and other foreign matter with wire brushes and small picks, sweeping with brooms or soft brushes and finally dusting with old gunny bags and compressed air to receive bituminous treatment complete as per clause 502 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 90 Extra for additional bitumen emulsion used in above item for every 1 kg per 10 sqm 91 Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as per Table 500-23, premixed with bituminous binder @ 14.60 kg/ 10sqm (including Cost of anti-stripping compound Minimum 1% in Lime/Cement as per design wherever required), including loading of material with F.E. loader, hot mixing of stone aggregate and bitumen in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control to the required level and grade, compacting smooth wheeled roller 8-10 tonne capacity and finishing to required level to achieve the desired density as per clause 511 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion but excluding cost of tack coat/ seal coat. 92 With Bitumen VG-grade 30 93 Providing laying and consolidation Semi Dense Bituminous Concrete, as per Design Mix (approved by Engineer), on prepared surface with specified graded crushed aggregates as per table 500-15 for wearing coarse including loading of material with F.E. loader, hot mixing of stone aggregate, filler and bitumen (including Cost of anti-stripping compound Minimum 1% in Lime/Cement as per design wherever required) heating and mixing in in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control to the required level and grade, compacting by power rollers and vibratory rollers or 150 to 250 KN pneumatic tyred roller with TP = 0.7 Mpa, to achieve the desired density (approximately 2.3 tonne/cum) complete as per clause 508 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion but excluding primer/tack coat. 94 25-30 mm compacted thickness (Grade-2) using Bitumen VG-grade 30 @ 5% (percent by weight of total mix) 95 Bored cast-in-situ R.C.C. pile with cutting / Drilling for anchoring of pile into rocks wherever firm rocky strata is available, shall be done upto desired depth (minimum 1.50 m) as per drawings, specifications and as directed by Engineer. Bore hole shall be cleaned properly before concreting. No, distinction shall be made for penetration through hard rock or rock socketing with design mix concrete (M-35) using batching plant, transit mixer and concrete pump excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. as per clause 1100, 1600 & 1700 of MoRT&H Specification including all material, labour and machinery. 96 450mm dia pile 97 Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum 98 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 99 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 100 M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 101 Supporting block of size 2m, 1.2m 102 For height 10m 103 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 104 Providing M-30 grade concrete by usingcement as per codal provision instead ofM-20 grade design mix. 105 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 106 Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 107 Columns, pillars, posts and struts etc. 108 Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: 109 Cost for Basic Service Charges, Administration and Management, Running of Operation, Maintenance and Repairs including Preventive Maintenance, Cost of material required for maintenance & repairs, Cost of Lubricants, Consumables, Spare Parts (if the spare parts supplied to PHED are used in emergency)as per Scope of Work & terms & conditions of contract for 05 year after defect laibility period of one year DLP (except power feeder, IEC & miscllenous provision) for Water Supply Project 110 1st year 111 2nd year 112 3rd year 113 4th year 114 5th year
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
34.
Metro Rail #10545528 Price Bid
tender for Maintenance Contract Of Civil Works Addition Alteration modification Repair Maintenance Of Various Stations Rss Buildings Between Mansarovar To Badi Chaupar And Any Other Metro Railway Premises Of Jaipur Metro Rail Corporation At Jaipur As Per Bid Documents - Maintenance Contract Of Civil Works : Addition, Alteration/Modification, Repair & Maintenance Of Various Stations & RSS Buildings Between Mansarovar To Badi Chaupar And any Other Metro Railway Premises Of Jaipur Metro Rail Corporation At Jaipur Sl. No. Item Description 1 6mm Toughened Glass in existing frame: Providing and Fixing 6mm thick clear float toughened glass in aluminium door, window, ventilator, shutters and partitions etc. with PVC/ Neoprene gasket etc complete as per architectural drawings and the directions of Engineer-In-Charge. 2 Providing and fixing in position Toughned glass of 12mm thickness all complete including minor cutouts/openings as per the direction of Engineer-in-charge. 3 Providing & Fixing of Floor Spring, Patch (Hydraulic) (OZONE MAKE) for Glass Door Assembly/Unit complete as per Directions of Engineer-In-Charge. 4 Providing and fixing tactiles 12mm thick yellow directional vitrified porcelain Granite tactiles (Australian made) laid on floor with laticrete 111 crete filler powder mixed with laticrete 73 latex admix and applied to a minimum thickness of 4.5 mm. The mixing ratio shall be as follows : 20 Kg Bag (Laticrete111):5.5 Ltr (Laticrete 73) spacer of 3 mm shall be used between the tiles and joints filled using laticrete Latapoxy SP-100 epoxy grout in Inca gold colour. The joint depth shall be 6 mm. Laticrete product shall be procured by Laticrete India Pvt Ltd/Laticrete International Inc (Tiles for blind people - directional tiles as installed in JMRC station) 5 Repair of defective rolling shutter with using any material required for bend repair,tightening of spring,bolt & screw and welding by welder as a complete job as per direction of Engineer In charge.(Upto 12 Sqm in area)(This item includes cost of necessary scaffolding,all lead & lift and consumable i.e welding electrodes of required specifications as per site requirements) 6 Extra For Reparing of Rolling Shutter having size more than 12 sqm in area 7 Skilled labour for sewerage chamber/pipe line cleaning/clearing choking with all T&P including all required machinery. 8 ROCA meridian-N soft close seat cover white 9 Providing ofaccess raised floor of light grade (15 KN/m2) UDL panels manufactured from pressed formed corrosion resistant galvanised steel with total overwrap of one piece top, sides and bottom flange encapsulating high performance chip board case stiched and with a panel to cater in the size 600*600*31mm with new panels of same specifications complete in all respects. the acess floor should be able to take a point load of 2.5 KN over 25 mm sq. and UDL of 15 KN/sqm. The panel shall be finished with high abrasion , anti-static HPL of formica colour Y606 having fire rating as per BS 476 clause 5, 6 & 7. 10 Supplying and fixing rolling shutters of approved make, made of 80 x 0.8mm color coated G.I Laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets of M.S, side guides of G.I and arrangements for inside and outside locking with push and pull operation complete including cost of sring hooks, providing and fixing necessary 45.0 cm. long wire springs grade No-02 including dismantling of existing rolling shutter as per the directions of Engineer-In-Charge. 11 Colour Coated G.I Top Cover 0.5mm thick for rolling shutters as per instructions of Engineer-In-Charge. 12 Providing and fixingpink dholpur sand stone work of size as specified below, of approved colour/patternat all levels for wall lining/Columns (veneer work) by mechanical arrangement with S.S.Cramp/ brackets,.Anchor bolts,5mm vertical S.S. of approved make. Inserts as per drawings and specifications. The cost for making necessary grooves in the stone to accommodate the vertical inserts, grooves all-around stone pieces, making 10mm deep rebate for tile inlay, chamfering of corner edges and polishing are included. 13 pink dholpur sand stonesize (1600-1800)x600x25mm minimum thick 14 Providing and laying 30mm thick FLAMED Sadarhalli Grey Granite Stone flooring in treads and landings (including bull nosing, rounding the nose and making groove) of stepsof approved colour, size and pattern, (sample of granite stone shall be approved by Engineer-in-charge) over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with neat cement slurry mixed with pigment to match the shade of granite stone complete as per specifications andas per direction of engineer-in-charge. 15 Extra for Red/ Raw Silk/ Tan Brown/ Jet Black granite Stone 16 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 17 Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge. 18 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in- Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Epoxy injection grout in concrete/RCC work of approved make. 19 Providing and applying crystalline mortar by mixing in the ratio of 4.5: 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 ?45 MPa and adhesive bond strength Class R3 ?1.5 MPa. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat. 20 Strengthening of existing open cell metal false ceiling by clipping assembled cell ceiling panels into extra U-profile carriers (as per requirement) in Galvanized Mild steel, pre-coated in black enamelled finish. In addition to the carriers, extra C-profile wire clips shall be fixed to hold the cell ceiling panels into the carriers for strengthening. Further, for lateral strengthening,extra angles made out of Galvanized Mild steel shall be fixed for cross connection with U-profile carriers. Payment shall be made on the basis of unit plan area measured. This item includes all material, labour, night charges, scaffolding, transportation, taxes etc. 21 Providing and fixing 12 mm thick partition/doors assembly of solid acrylic material with stainless steel hardware complete in toilets. 22 Providing and fixing backlit or high quality flex prints of high resolutionimages and to be pasted or installed on the walls or any other surfaces,of approved size and design as directed by the Architect. Necessaryframework in wood or aluminium to be provided for mounting of flex panel asrequired or as directed by the Architect. Flex panel to be installed takingutmost care to avoid any damages or stains on walls etc. In case of theinstallation or printing is found unsatisfactory the sheet to be replaced withnew with necessary corrections as part of rectification works. Item to includeall necessary tools, Flex and printing, framework for mounting of flex panelscaffolding if required etc. complete 23 Providing and fixing Small Size MDF Bases for mounting Sculptures of required sizes and design as directed by the Architect. Base to be made using 19mm MDF sheets including necessary wooden framework if required and finished with Duco paint of approved shade and type as directed by the Architect. Item to include all necessary tools, hardware etc complete in all respects. 24 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 25 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 26 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 27 Providing and fixing 8mm thick Black Painted Toughened Glass Clading on walls of required size and design as directed by the Architect. 8mm thick Marine Plywood backing to be provided behind the glass, to be fixed over 25mm x 25mm teak wood framework fixed to wall @ 1.2M c/c or as required as per site conditions. Item to include providing necessary lipping to hold glass in place, tools, hardware etc. to complete item in all respects. 28 Manufacturing, supplying and Fixing retroreflective overhead signage boards made up of 2mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retroreflective sheeting confirming to type III of ASTM-D-4956-01 as approved by Engineer-In-Charge, letters, borders etc. as per IRC:67-2001 in silver white with blue color background and with high intensity grade, pasted on substraight by pressure sensitive adhesive backing which shall be activated by applying pressure confirming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts and nuts @ 300mm centre to centre all along the periphery as well as in 02 vertical rows along with theft resistantmeasures, including the cost of painting with two OR more coats of epoxy paint in grey color on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specifications and directions of the Engineer-In-Charge. (Structural Frame work Including M.S Plate to be provided seperately. Rectangular area of the sheet only shall be measured for payment). 29 ILLUMINATED SIGNS:Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per relvant drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-In-Charge. 30 SIGN FRAME:-The sign frame shall be made out of aluminium extruded sections fabricated to required sizes and shape. Item to include providing and fixing of aluminium channel spot welded to sign frame including channel supports are to be powder coated to match as per apptoved colour or in colour duly approved by Engineer-In-Charge. The inside edge of sign frame to have EPDM gasket where it gets in contact with the sign panel as per approved design is required.All powder coating shall be done on all internal as well as external surafaces. The Sign shall be internally lit with the specified luminare (LED MODULE) and item to include providing and fixing luminare and fixtures comple as per the technical specifications for electrical works. 31 SIGN PANEL:- For elevated and underground stations.Providing and fixing sign pannel made out of 04mm thick polycarboate sheeting with vinyl message (3630/7725 series 03M OR equivalent) to required sixe and shape. Vinyl colour to match graphics and text as per schedule and pasted on sign panel. All the confont in the signage will be plotter cut/screen printing. The signage will be laminated for the protection of plotter cut vinyl pasted on sign panel. For double side 32 REFLECTOR PANEL:- Item to include providing and fixing embosed aluminium mirror reflector panel as per approved specifications and make, with provision to hold luminaries in position. 33 BACK PANEL:- For elevated and underground stations.For single sided signs, where graphics/text is to be on 01 side. Item to include providing in embosed radiant mirror reflector, back panel to be pure polyster coated to match as per approved colour as per technical specifications.ACCESSORIES:- Providing and fixing all accessories such as magnetic catchers, hinges, spring clips, anchoring hooks, nuts, cleats, screw hooks and slots etc complete as per specified fabrication drawing. All anchor fastener, bolts etc to be SS-304 Grade.Above description holds good for the following signage unless otherwise specified except for modifications due to their respective finished dimensions and fixing arrangement OR unless otherwise specified. 34 ILLUMINATED FACE MOUNTED SIGN:- (At Height of Roof at Entry/Exit and at room height of Underground Metro Stations Badi Chaupar and Chhoti Chaupar)The sign frame is to be mounted on BRICK/RCC wall backing with cladded or Non cladded.Item to include aluminium sign frame of required size and shape including mounting the sign frame on the RCC/BRICK wall backing by drilling holes of required diameter in the RCC/Brick Wall and achoring the sign frame using HILTI FASTENERS or Equivalent or specified size and length and providing and fixing all item and accesaories including silicon sealant and backer rod of approved make complete as per drawing for following panel sizes. The mounting surfacesshall be required and finished as per surrounding area complete at no extra cost. This sign is to be necessarily signle sided only. All achor fasteners, bolts etc to be SS-304 Grade. (SIZE: 2400mmX900mm Approx. OR 5200mmX1000mm Approx. Depth of SIGN DEPTH: 75mm OR as approved by EIC) 35 Supply and Installation of Vinyl Sheet (03M) in UV Print on existing signages at metro stations of Jaipur Metro. 36 Providing and fixing 120 minutes steel fire rated doors as per detailed specifiction made by shakti mate, Godrej etc. Along with hinge and door closer as per nfpa 80 and as per NFPA 252, temperture increase on the unexposed surface not exceeding on average 361.c (650.F) during first 30 mins of test size as per directions of Engineer in charge. 37 Re-alignment of misaligned doors by taking out the door and the door frame (as per site requiement), rectifying and re-fixing of the same. The door shall be made good using any fixtures required (except hinges, door closer, trim paces, panic bars) and nithing shall be paid extra in line of the same. The work shall be carried out as per the direction of Engineeer in charge. 38 Removing of old paint, rust with help of power tool and preparing the surface to various standards (ASA 3.0) before application of primer. The rate will include all tools, plants, labour and other consumables and incidental charges. Nothing shall be paid extra. Except NBSR no.1, 3,4,5 and 6. The surface which are not accessible with the help of power tool shall be prepared with wire brush. 39 Applying surface tolerant epoxy coating in two coats with epoxy based primer with minimum DFT of 200 microns at all locations wherever required and volume of solids not less than 75%. Paint is to be applied with spray painting, in place where its inaccessible it may be applied with brush (item to be used where surface is having scaling.) 40 Application of finishing coat epoxy polyurethane system of approved quality brand ot UV resistant coat at all locations and colour to achieve smooth & even surface with minimum volume of solids 57% and of 75 microns thickness of surfaces. 41 Providing and fixing of Anti Birds Spikesmade of high quality of Poly Carbonate, 5 Row 304 mm. Rates are inclusive of screws, cable ties, adhesives, fasteners up to 5 meter Height complete as per direction of Engineer-in-Charge. 42 Supply 5-7.5 HP submersible pump of discharge capacity 50-60 kl/hrs including cost of operation etc complete. 43 Cladding Work 44 Granite cladding work : Providing and laying 30 mm thick mirror polished Sadarhalli Grey/Cheema Pink/Jhalore Beige granite stone work of up to and including sizes of 1200mmX600mm of approved colour/ pattern with 4mm groove all around at all levels for wall linings/ columns/ cladding/skirtings (veneer work) by mechanical arrangement with SS cramps/ brackets, anchor bolts, 6 mm vertical SS pins of approved make and inserts as per drawings and specifications. The cost of making necessary grooves all around stone pieces, chamfering of corner edges and polishing are included. 45 Extra for Red/ Raw Silk/ Tan Brown/ Jet Black granite 46 Removal of old expansion joint, repair of site and providing & fixing of BITUFLEX close cell form twice for overlaping of close cell form joints filling of POLYDEEN GROUTFAST or equivalent non curing mortar and applying POYDEE liquid membrane or equivalent on the entire area of expansion joint mfg by M/S Greensboro Polychem Pvt. Ltd Or equivalent and fixing of 6 mm thick and 150 mm wide aluminium sheet one with sliding screw complete as per direction of Engineer- In-Charge 47 Polishing and buffing of SS 304 railing/SS surface provided in metro stations with minor grinding(as required) and removing stains/blemish with proper rubbing and polishing. The surface with suitable material and finally buffing the surface with high speed buffing machine using buffing material complete as per dierection of Engineer In Charge. The work will be carried out in non revanue hours and rates are inclusive of all taxes man power material, tools and plants, CO and OH etc all complete. 48 Providing skilled manpower such as welder/fitter for welding works along with welding machine to carry out welding as per direction of Engineer-In-charge including cost of tools, safety equipments,consumable(electrodes) etc. 49 Providing semiskilled manpower such as Plumber/carpentor/mason/ for plumbing/sewerage/carpentory/masonary, rectification works with all required T&P complete as per direction of Engineer-In-charge. 50 Providing unskilled manpower such as helper/beldar etc for miscelleneous Civil works with all required T&P as per direction of Engineer-In-charge. 51 Supply of potable water through water tankers o capacity 5000 liters at stations of JMRC from MSOR-BICP
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
35.
Communications and Information Technology  #10537185 Price Bid
Operation & Comprehensive Maintenance Of Electromechanical Services For Bsnl Admin Bldg, Sara Complex And Wireless Compound At Santacruz ( W ) , Mumbai-54., Comprehensive Maintenance And Round The Clock Operation Of Various Electromechanical Services As Per Details Given In Relevant Sections By Deploying The Required Staff / Or By Automation Including Specialized Manpower And By Arranging Required Tools And Plant Etc To Keep All The Services Operational Upto The Required Standards . A ) Admn . Bldg . - Services Included Are: 1 ) Ei & Fans 2 ) Compound Lighting 3 ) Lightning Conductor 4 ) Pumps 5 ) 2 X 400 Kva ( 11 Kv Indoor ) Substation 6 ) 1 X 380 Kva Ea Sets 7 ) Fire Detection And Alarm System 8 ) Window & Split Ac Units I / C Casette Type Ac 9 ) Fire Extinguishers 10 ) Fire Hydrant System ( Excluding Underground And Surface Mounted Pipes But Including Valves , Hydrants , Engines , Pumps Etc . Like Major Items ) B ) Wireless Compound -Services Included Are: 1 ) Ei & Fans 2 ) Compound Lighting 3 ) Lightning Conductor 4 ) Pumps 5 ) Fire Detection And Alarm System 6 ) Window & Split Ac Units 7 ) Fire Extinguishers , Contractors To Take All Steps To Undertake Preventive / Special Maintenance And Testing To Keep The System At Optimum Working Condition . Size Of Various Services Is Given In Section- I B ) Minimum Staff Required : Morning Shift : 1 Wireman General Shift : 1 Wireman + 1 A / C Mechanic + 1 Helper Second Shift : 1 Wireman Note: Engineer In Charge Can Rearrange Shifts As Per Site Requirement Subject To Maximum Shifts Specified In A Day . If More Persons Are Required For Satisfactory Operation , The Same Shall Be Arranged By The Firm At No Extra Cost . Lodging Of Lift Failure Complaint , Monitoring & Maintaining Log Book Of Complaints Has To Be Carried Out By The Agency . , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I / C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . I ) 1X 380 Kva Dg Set , Supplying & Fixing Of Fully Charged 12 Volt , 180Ah Lead Acid Maintenance Free Battery For Starting Of 500 Kva E / A Sets Complete With End Sockets Etc . Note- 1 ) The Battery ( S ) Of Each Dg Set Shall Be Replaced ( Measurable Basis ) Once During Currency Of Contract & Agency Shall Consider Rebate For Old Battery While Quoting Of Rates . Additional Requirement To Be Borned By Agency Without Extra Cost .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
36.
Communications and Information Technology  #10537170 Price Bid
Ocm Of Ems For Telephone Bhavan Ahmednagar 2Nd Call , Comprehensive Maintenance And Round The Clock Operation Of Various Electromechanical Services As Per Details Given In Relevant Sections By Deploying The Required / By Automation Means Including Specialized Manpower And By Arranging Required Tools And Plant Etc To Keep All The Services Operational Upto The Required Standards Except Item Nos . 2 & 3 Below Which Shall Be Paid Extra As Per Running Hours Of Dg Sets . , A ) Services Included Are 1 ) Ei & Fans2 ) Compound Lighting3 ) Lightning Conductor4 ) Pumps5 ) 2 X 400 Kva ( 11 Kv Indoor ) Substation6 ) 2 X 500 Kva Ea Sets7 ) Fire Detection And Alarm System8 ) ( 4+2 ) X 7 Tr , , ( 3+1 ) X 7 Tr & 1 X 10 Tr Package Type A C Plant9 ) Window & Split A/C Units 10 ) Fire Extinguishers , Contractors To Take All Steps To Undertake Preventive / Special Maintenance And Testing To Keep The System At Optimum Working Condition . Size Of Various Services Is Given In Section - I , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I/C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . , I ) 2 X 500 Kva Dg Sets , Supplying & Fixing Of Fully Charged 12 Volt , 180Ah Lead Acid Maintenance Free Battery For Starting Of 500 Kva E/A Sets Complete With End Sockets Etc . Note-1 ) The Battery ( S ) Of Each Dg Set Shall Be Replaced ( Measurable Basis ) Once During Currency Of Contract & Agency Shall Consider Rebate For Old Battery While Quoting Of Rates . AdditionalRequirement To Be Borne By Agency Without Extra Cost .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
38.
Drinking Water Supply and Sanitation #10523073 Price Bid
Tender For Interception & Diversion (I&D) & Stp For Existing Drain In Dhampur Town/Npp, Distt Bijnor - Civil Works of 7.2 MLD STP and 7 KLD Septage Co-Treatment Facilities 2 Design, Construction, Supply of all materials, Erection and Commissioning of 7.2 MLD STP and 7 KLD Septage Co-Treatment Facilities with all the civil,LT/HT panel room, sub station building, DG set foundation, admin buidling, laboratories, meter room and campus development [Construction of Internal Road (CC Road, 3.6m wide, area approx 2000sqm),fiiling of earth if required]fully furnished administrative building having fully functional testing laboratory, PLC/SCADA Rooms, Power Generation building, Blower building, sludge handling system & other building required for technology proposed. OCEMS system at inlet & outlet of STP and master control station (MCS) at STP. Conference room suitable for 15 people, 4 rooms with a attached toilet for supervisory staff and a toilet block, drinking water cooler, all office rooms and conference room (Air Conditioned)., staff quarters as per requirement and specification, external water supply (20KL tank including tube well and pumping arrangement,sanitation work) etc. all complete for STP with co-treatment facilities. STP shall be based on SBR Technology OR any proven technology. The effluent quality for agricultural uses (PH-6.5 TO 8.3, SS-30 mg/l, Oil&Grease-10 mg/l, BOD-10mg/l) , COD-30 mg/l , Residual chlorine-nil , TKN-10mg/l, Nitrate N-10 mg/l, F.C.-230 MPN/100 ml, Dissolved P-5 mg/l (preferable 2 mg/l). ) shall be maintained asper CPHEEO manuals. Latest NGT norms for effluent discharge shall be adhered. The cost is inclusive of (Peak flow 24.11 MLD) (civil works). 3 INTERCEPTOR SEWERExcavation below G.L. upto depth as specified for laying sewer and manhole ordinary soil (earth, sand, loam and clay) including cutting of joints pits ramming dressing) leveling, refilling of trenches in 20 cm layer watering and ramming the same including (8% reduction due to excavation already taken in manhole and SCC) 4 (a)0.00 to 1.50 m 5 (b) 01.50 to 03.00 m 6 (c) 03.00 to 04.50 m 7 Provide and fix close timbering in trenches for the depth as specified below G.L. consisting of 40 mm thick approved country wood plank for polling board 125 x 75 mm eucalyptus-Safeda-Sal Wood wallers and 100 mm dia ballies for shuttering at 1.5 m C/C including all labour etc , complete 8 (a)1.5 to 3 m 9 (b) 03.00 to 06.00 m 10 Same as item No. 3 but for open timbering (No timbering for depth <1.50m) 11 (a) 1.50 to 03.00 m 12 Timbering left in trenches (No timbering for depth <1.50m) 13 Open Timbering left in trenches (used timbering) 0-3m depth 14 Closed Timbering left in trenches(used timbering)0-3m depth 15 Closed Timbering left in trenches(used timbering)3-6m depth 16 Supply of following sizes of RCC spigotted and socketed non pressure pipes( Dia. In mm ) with structural strength as per IS 458 : 2003 and its latest amendment(s).NP3 17 600 mm dia 18 700 mm dia 19 Carting following sizes of R.C.C. Hume pipe NP3 Class Socket / spigot rubber ring jointing and specials from store to the work lowering and laying the same in to the trenches upto depth as specified below G.L. true to alignment600 mm dia pipe 20 01.50 - 0 3.00 m 21 03.00 - 04.50 m 22 700 mm dia pipe 23 01.50 - 0 3.00 m 24 Cement concrete work in bedding below G.L. at specified depth with cement, coarse sand and 20 mm gauge approved stone ballast (1:2:4) including supply of all materials, labour, T&P etc. required for the proper completion of work. 25 (c) 03.00 to 04.50 m 26 Filling granular material (well graded crushed rock or gravel maximum size 20mm) into the trenches for class B bedding (granular bedding) including watering compaction, labour T&P etc. for completion of work. 27 (b) 01.50 to 03.00 m 28 Supply (excluding cartage) of granular material (well graded crushed rock or gravel of maximum size 20mm)for class B bedding (granular bedding) 29 Construction of circular type brick masonry HD (HD25) manhole (with Extra Heavy Duty type manhole cover) with top slab made of cement concrete 1:1.5:3 with graded granite stone aggregate (12 mm nominal size), wall made of brick masonry using 1st class bricks having crushing strength between 100 to 149 kg/cm² in cement mortar 1:4 inside plastering 12 mm thick 1:4 finished smooth with neat cement, pinning, outside plaster 1:4 and making channels with cement concrete 1:2:4 graded granite stone aggregate (12 mm nominal size) complete with including Plastic Encapsulated M.S. foot Rest staggered at 0.375 mtr interval, including excavation, reinforcement. 30 1200mm internal dia., 3.30m deep 31 1500mm internal dia., 4.95m deep 32 Extra for every additional depth of 1 m or part there of in following size of circular manholes. 33 1200mm internal dia., 3.30m deep 34 1500mm internal dia., 4.95m deep 35 Dismantling/Cutting of Cement Concrete road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materialsas per direction of Engineer Incharge. 36 Reinstatement of Concrete road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials as per direction of Engineer Incharge. 37 Providing and erecting temporary barricading at site as per drawing/ direction of Engineer-in-Charge which includes hiring of Ballies and arrangement for traffic diversion such as traffic signals during construction at site as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). The rate is for unit length of pipe laying. 38 Disposal of Surplus Earth as per direction of Engineer Incharge. 39 Construction of Boundary Wall 2.0m ht. above plinth level 0.23m width with RCC Column @3m c/c with plinth beam and foundation avg. 2 m depth including reinforcement and RCC coping on top of wall with plaster (1:4) and painting (apex painting 3 coat) as per type design and drawing at the STP site 40 MS gate (3.6m wide with 1.50m wicket gate with 0.35 m x0.35m RCC piller) 41 Cnstruction of Intermediate Pumping Station (IPS) as per specification, accesory building & design approved by Engineer in Charge 42 Sewage Rising main from IPS Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as per direction of Engineer Incharge. 43 0.0 to 1.5 mtr. Depth (do - in all kindes of soil) 44 Supply of 400mm dia. DI K9 pipe and special for the pumping mains including all complete pipes conforming to IS : 8329- 400 mm 45 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.(400mm) 46 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete 150 mm 47 Carting of 400mm dia DI K9 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc. 48 Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, withcast insitu RCCslab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing 49 Sluice valve, Air valve chambers 50 Dismantling/cutting of the BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 51 Reinstatement of the BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 52 Interception and diversion (I&D) Structure works 53 Cnstruction of Interception and Diversion Structure works as per specification, accesory building & design approved by Engineer in Charge 54 Treated Effluent line (400mm Dia DI K7) (STP to Disposal point (Khow river) 55 Excavating trenches for pipes including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as directed, within a lead of 50 m.0.0 to 1.5 mtr. Depth do - in all kindes of soil 56 Supply of 400mm dia. DI K7 pipe and special for the pumping mains including all complete Pipes conforming to IS : 8329- 400 mm 57 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc.all complete required for completion of work (400mm dia) 58 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. all complete required for completion of work150 mm 59 Carting of 400mm dia DI K7 pipe and specials from store to the work lowering the same in to the trenches upto depth as specified below G.L. inclduing testing of pipes etc. 60 Providing & Constructing masonry Chamber 1.5x1.5x1.5 m inside, in brick work in cement mortar 1:3 (1 cement : 3 coarse sand) for valve, withcast insitu RCCslab with necessary reinforcment.The valve chamber shall be plastered with CM 1:4, A levelling coars of M10shall be provided.The cost is inclusive of excavation , disposal and construction of valve chamber with moduar bricks plasting with cement mortar with all lead and lift etc., as per specification & drawing. 61 Sluice valve, Air valve chambers 62 Dismantling/cutting of BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 63 Reinstatement of BOE road for laying sewers, manholes, sewer connection chambers etc.including shorting out and stacking serviceable materials and disposal of unserviceable materials upto distance of 50 m. 64 E/M WORKS 65 STP ( 7.2 MLD ) And Co Treat ment Plant ( 7 KLD ) 66 A. Design, Supply of all Materials, Erection, Testing,Commissioning and 3 month trial run Of Electrical, Mechanical & Instrumentation Equipments at STP (7.2 MLD )with all required electrical& mechanical works, PLC/SCADA work, electrification & street lighting work and Online Continuous Effluent Monitoring System (OCEMS) etc. all complete as per tender documentfor STP.The effluent quality for agricultural uses ( PH-6.5 TO 8.3,SS-30 mg/l, Oil & Greases -10mg/l, BOD- 10mg/l,COD-30 mg/l,Residual Chlorine-nil, TKN-10mg/l, Nitrate-10mg/l, FC-230MPN/100ml Dissolved P-5mg/l (preferable 2mg/l).) shall be maintained as per CPHEEO mannuals Latest NGT norms for effluent discharge shall be adhered. The rate is Considered for SBR Technology. The STP shall be capable to treat the raw sewage having minimum concentrationmentiond in CPHEEO mannual. Firm has to complete Design, Supply, Erection, Testing,Commissioning and 3 month trial run of Substation Work like HT Panel, Transformer & its associated equipments and DG Set Work with AMF Panelwith considering load of STP and MPS both.B. Design, Supply of all Materials, Erection and Commissioning and 3 month Trial Run of Co-Treatment Plant ( 7 KLD ) having manual screen with-SS 304 with bar size (50 mm x 10mm) and gaping 20 mm, Screw Pumps (2 Kl/h 1W+1S), Screw Press Machine (3 KL/H) with double cylinder having VFD for its operation , 1000 Lit. PVC tank for washing screw press machine. all type pipe and fittings, LT panel and cabling material,Dewatering Pumps (1W+ 1S), 2HP Blower with 6 Nos Diffusers etc complete. including Supply and 3 month trial run of 1 No. 1500 Lit. Cesspool Vehicle having 30 HP Reputed make Tractor (with Registration Certificate and insurance papers) 67 E./M. Works at MPS 68 Electrical Works 69 H.T.Panel( Comprising with 1 -I/C and 2 -O/G. (panels should be TYPE TESTED ASSEMBLY ( TTA) type only) 70 SITC of Indoor Type Floor mounted HT Panel with11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- 71 Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel.- Numerical relay (should be VCB manufacturers own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. (1set, included in STP costing) 72 Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimalfailure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- Numerical relay (should be VCB manufacturers own make) having protectionsof 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input ,programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) (2 sets, included in STP costing) 73 Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. (included in STP costing)3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) -60 metersTrench making and covering of trench in all respect.- 60 metersSITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) - 4 sets11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV - 2.5 SqmTransformer:Suitable capacitywith Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of suitable capacity rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. (included in STP costing) -- 2 Nos. 74 L.T. Panel (panels should be TYPE TESTED ASSEMBLY ( TTA) type only)SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operatedon 415 ± 6 %volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii)C.Ts of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v)Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi)Frequency meter-1 No.(vii)KWH meter - 1 No. (viii)2 Pole over current relay& one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 6 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 63 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 3 Nos. outgoing panels for miscellaneousworks, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (E)APFC Panel for total load.(F) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels 75 LT Cable laying and jointing 76 Power and control cable-Supply of 185 sq. mm 3.5 core cable - 2 Run required for power fromeach Transformer to each L.T. panel , 50 sq. mm X3 core-1 run cable for power from starters to Motor including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation systemetc. complete in all respect. 77 Earthing 78 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. 79 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, BottomDia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. 80 Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing) 81 Charges of Electrical safety Clearance 82 Expenditure on B&L Form, Challan etc. 83 Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage) 84 STARTER PANEL 85 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 20 HP motor (To be fixed in composite panel of LT Panel) 86 Mechanical Works 87 PumpThesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (4W+2S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump= 3110 lpmTotal Head= 16 M or as per designSpeed=980Quantity of pumps. 88 Guid Rail System 89 Guide rail system (Automatic coupling system) for 20 HP submersible pump setscomplete for above pump set.(6 Sets, included in item no. 51.01) 90 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (6 Sets, included in item no. 51.01) 91 Main piping and Valves.Main piping and valves 200 mm dia delivery, 350 mm diacommon header line. 92 Valves.Confirming to IS 780/2906 or as applicable PN rating- 1.0Type of liquid to be handled-potable water 93 Material of constructionBody-CI,IS-210 grade FG 200Wedge-CI IS210 Grade FG200Spindle-Stainless steel AISI304Sheet and face Ring-SS ASTMA 743 Grade C.F.8 MChannel& Shoe-S.S.AISI,.304Drain& Air plug-S.S.AISI.304Bushing arrangement-Halprene on bronzeRivets-AISI:304Fasteners-MS 94 Motor Operated Sluice Valves 95 Sluice Valve 200 mm dia 96 Sluice Valve 350 mm dia 97 Reflux Valve 98 Reflux valve 200 mm dia N.B. 99 PipingsNote : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing taking 200mm pipe 60m and 350 mm pipe 15m . 100 200 mm, K9 delivery pipes for all six pumping plant 101 350 mm, K9 common header pipes 102 Specials like bend, tee, D Joint etc. 103 Nut Bolt, Washer Rubber packing etc 104 INSTALLATION, TESTING & COMMISSIONING 105 Installation & Commissioning of all 6 Nos. Pump set,Piping & Valves as mentioned in above. 106 Level Transmitter (For Hi-Lo cut-off & alarms) 107 SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display. 108 Electro magnetic flow meter 109 SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line. 110 E.O.T. Crane 111 SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendent control block. 112 Chequerred plate and guards 113 SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition (Ref. UP Jal Nigam, GM Gzb Rate) (3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm. 114 PAINTING 115 Painting of all pumps piping and valves with two coat enamel paint. 116 LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019) 117 Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan 118 Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan 119 IPS Campus with Solar Panel and LED Light of 3 sets. 120 D.G. SET AND ACCESSORIES 121 SITC of Radiator Cooled and Turbo charged Silent type suitable capacity DG set , engine ,alternator capable of developingat 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. (1 set, included in stp costing) 122 SITC of PLC Based Auto main failure (AMF) Panel forDG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect.(1 Set, included in stp costing) 123 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.(2 Job, included in stp costing) 124 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required. (2 Jobincluded in stp costing) 125 Supply & Laying 50 mm X 6mm sizeGI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. (1 Job, included in stp costing) 126 Providing and Laying cable for DG Set to Panel ( armored aluminium )-(1 Job, included in stp costing) 127 Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 185 sq mm. (4 Jobs, included in stp costing) 128 SCREENS AND GATES: 129 Rising type thimble mounted CI Sluice Gates of reputed make at IPS 130 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at mid year peak discharge (1w+ 1s) 131 Packing and Frieght 132 Installation, Testing and Commissioning 133 AUTOMATION OF MPS 134 CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places. 135 GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 136 CE/UL certified intellignet Smart Energy Meter 137 Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 138 160 AMP rating 139 Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator. 140 CE/UL Certified Surge protector for control panel. 141 CE/UL Certified 7 HMI touch screen suitable to communication with PLC/RTU for local display & control ofp rocess parameters. 142 Security Survillance IP Camera with recorder 143 Installation, commissiong & testing of above automation work 144 Expenditure on Operation & Maintenance of MPS including automation, Diesel Consumption & Electricity Consuption During 3 month Trial and Run Period 145 E./M. Works at IPS Dhampur 146 Electrical Works 147 H.T.Panel( Comprising with 1 -I/C and 2 -O/G .(panels should be TYPE TESTED ASSEMBLY ( TTA) type only)SITC of Indoor Type Floor mounted HT Panel with11 KV, 630/800 Amps 3 phase, 50 Hz Vacuum Circuit Breaker (VCB) Panel Fabricated by System Integrator of VCB Manufacturer as per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasification with suitable capacity of bus bar connected with the incoming and outgoing panels as per given details- 148 Supply installation testing and commissioning of Incoming Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VA should be floor mounted and to be connected from the back side of the panel.- Numerical relay (should be VCB manufacturers own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. 149 Supply Installation Testing and Commissioning Outgoing Panel comprising of following: - VCB 630/800 Amps . VI of VCB should be sealed for 30000 operation. VCBoperationg mechanism should be of M2 duty for minimum 10000 mechanicaloperation. - Closing & tripping coil of VCB should be of continious rating to achive minimalfailure. - Resin Cast type CT having Ratio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement)- Numerical relay (should be VCB manufacturers own make) having protectionsof 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input ,programable 6 Digital Output and programable 4 nos. LED at HMI.- Ammeter with Selectorswitch and Volt meter with Selector switch- Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA,KVAR, PF, KWH, KVARH, KVAH, A,V etc.- Trip circuit supervision relay (feature of numerical relay)- LR, TNC switch, indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) 150 Providing & Laying XLPE insulated as per IS:7098/II/85 H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench, on existing cable trays or on surface etc. including making necessary connection, testing etc. 151 3 core X 120sq.mm. armored HT Cable (From HT Panel to Transformers) 152 SITC of 11 KV End Termination Kit Indoor type (3 core, 120sq.mm) 153 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break DownVoltage 45 KV 154 Transformer: 315 KVA with Off -LTC (+5% to - 10% @ 2.5%) : S I T C of star rated Copper wound distribution Transformer of 315 KVA rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect. 155 L.T. Panel (panels should be TYPE TESTED ASSEMBLY ( TTA) type only) 156 SITC of 0.415 kV L.T. control panel for pumping plant-L.T. control panel suitable to operatedon 415 ± 6 %volt , 3 Phase , 50 Hz, AC supply as per details given below-(A) 2 Nos incoming ACB panels and 1 No outgoing ACB panel, each consisting of following items -(i) 4 pole Microprocessor based release Draw out type ACB (Motorised charging type) ,630 A Rating ,50 kA- 1 No.(ii)C.Ts of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Voltmeter with selector switch- 1 No. (v)Power factor meter(0.5 Lag&0.5Lead) - 1 No.(vi)Frequency meter-1 No.(vii)KWH meter - 1 No. (viii)2 Pole over current relay & one pole earth fault relay - 1 No.(B)Bus bar chamber having 3 Nos. bus bars for phase and 1 No. bus bar for neutral of suitable size – 1 No. (C) 3 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 400 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (D) 2 Nos. composite panels for pumping plants, each consisting of following items –(i) 4 pole MCCB 100 A current rating, 50 KA short circuit breaking capacity With Microprocessor based release with adjustableadjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection -1 No.(ii)C.Ts. of suitable ratio- 1 No.(iii)Ammeter with selector switch - 1 No.(iv) Automatic start / stop device according to level in the sump- 1 No.(v)Indicating lamps(Auto/manual/low level/ reverse rotation) - 1 Set (E) 3 Nos. outgoing panels for miscellaneousworks, each consisting of following items – (i) MCB of 40 A capacity- 1 No.(ii) C.Ts. of suitable ratio- 1 No. (iii) Ammeter with selector switch - 1 No.(iv) Indicating lamps- 1 Set (F)APFC Panel for total load.(G) 4 pole Microprocessor based release Draw out type (Motorised charging type) ,630 A Rating ,50 kA Panel for DG sets incoming - 1 NO (G) Bus coupler arrangement in panels 157 LT Cable laying and jointing 158 Power and control cable-Supply of 240 sq. mm 3.5 core cable - 2 Run required for power fromeach Transformer to each L.T. panel , 240 sq. mm X3 core-1 run cable for power from starters to 67 KW Motors & 35 sq. mm X3 core-1 run cable for power from starters to 15 KW Motors including lugging and jointing, laying, trench excavation and compaction as well as complete cabling of automation systemetc. complete in all respect. 159 Earthing 160 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. 161 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. 162 Supply & Laying of 50mmX6mm size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting,soldering, saddles, Jointing shall be done by overlapping and with 2 set of GI nut bolt & spring washer spaced at 50cm making connection etc.(20meter for each earthing) 163 Charges of Electrical safety Clearance 164 Expenditure on B&L Form, Challan etc. 165 Proper fencing of substation portion as per I.E. rules. (Ref. Ongoing AMRUT Work Aligarh Sewarage) 166 STARTER PANEL 167 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 90 HP motor (To be fixed in composite panel of LT Panel) 168 SITC of Compraising of Soft Starter, suitable to meet the basic requirement of motor protections and suitable to run 20 HP motor (To be fixed in composite panel of LT Panel) 169 Mechanical Works 170 Large PumpsThesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 90 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (2W+1S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump= 5750 lpmTotal Head= 40 M or as per designSpeed=980Quantity of pumps. 171 Guid Rail System 172 Guide rail system (Automatic coupling system) for 90 HP submersible pump setscomplete for above pump set.(3 Sets, included in item no. 94.01) 173 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (3 Sets, included in item no. 94.01) 174 Small Pumps 175 Thesubmersible non clog pumpset should be single stage having two vanes enclosedimpellercoupled with submersible motor of 20 HP Rating 400 Volt ±10%,3 phase 50 Hz, solid handling capacity 125mm, suitable to pump raw sewage with an specific gravity 1.03 having following construction of material with 10 Met. cable as offered. (1W+1S)Casing-2% Ni Cl. IS.210 grade F.G.220 with hardness 275 BHN.Impeller-Stainless steel CF-8Mshaft-stainless steel AISI-410Discharge of pump=2500 lpmTotal Head= 17 MSpeed=980Quantity of pumps. 176 Guid Rail System 177 Guide rail system (Automatic coupling system) for 20 HP submersible pump setscomplete for above pump set. (2 Sets, included in item no. 98.01) 178 Lifting Chain , MOC- alloy steel, lifting chain with oval ring @ 1m & with D/Bow shackle (2 Sets, included in item no.98.01) 179 Main piping and Valves. 180 200 mm dia delivery for small pumps and250 mm dia delivery for large pumps, 350 mm diacommon header line. 181 Valves.Confirming to IS 780/2906 or as applicable PN rating- 1.0Type of liquid to be handled-potable water 182 Material of constructionBody-CI,IS-210 grade FG 200Wedge-CI IS210 Grade FG200Spindle-Stainless steel AISI304Sheet and face Ring-SS ASTMA 743 Grade C.F.8 MChannel& Shoe-S.S.AISI,.304Drain& Air plug-S.S.AISI.304Bushing arrangement-Halprene on bronzeRivets-AISI:304Fasteners-MS 183 Motor Operated Sluice Valves 184 Sluice Valve 200 mm dia 185 Sluice Valve 250 mm dia 186 Sluice Valve 350 mm dia 187 Reflux Valve 188 Reflux valve 200 mm dia N.B. 189 Reflux valve 250 mm dia N.B. 190 PipingsNote : Regarding the size of pipes, Tee, Bend etc, contrctor is required to designed them self and may got it approved by the department before execution of works along with layout drawing . 191 200 mm, K9 delivery pipes for small pumping plants 192 250 mm, K9 delivery pipes for large pumping plants 193 350 mm, K9 common header pipes 194 Specials like bend, tee, D Joint etc. 195 Nut Bolt, Washer Rubber packing etc 196 INSTALLATION, TESTING & COMMISSIONING 197 Installation & Commissioning of allPump set,Piping & Valves as mentioned in above @5% of supplied items. 198 Level Transmitter (For Hi-Lo cut-off & alarms) 199 SITC of Radar type level transmitter shall be provided in the pump house for measuring the sewage level in wet sump. The indicator shall be digital type showing depth in meters and shall be capable for input to PLC or HMI touch sceen for display. 200 Electro magnetic flow meter 201 SITC of CE/UL certified Electro magnetic flow metersuitable to measure 0 to 30 MLD flow to be fitted in 350 mm dia main header line. 202 E.O.T. Crane 203 SITC of 3 Tonn E.O.T. crane providing, erecting and commissioning single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendent control block. 204 Chequerred plate and guards 205 SITC of 3mm thick M.S chequerred plate over all the run of cables trenches to cover properly and M.S. grill and M.S. guard over all pipes ducts and other point where required as per site condition(3X0.75+3X0.9+7X0.6+1X0.9)X1=10.05sqmm. 206 PAINTING 207 Painting of all pumps piping and valves with two coat enamel paint. 208 LIGHT WIRING & Electrification (Ref. UP Jal Nigam E&M SOR, 2019) 209 Complete Internal Electrification of LT Panel room with 2 Nos. Exhaust Fan 210 Complete Internal Electrification of HT Panel room with 2 Nos. Exhaust Fan 211 IPS Campus with Solar Panel and LED Light of 3 sets. 212 D.G. SET AND ACCESSORIES 213 SITC of Radiator Cooled and Turbo charged Silent type DG set , engine ,alternator capable of developing 250 kVA at 415+6%, 50 Hz AC at 0.85 P.F. lagging and self exciting coupled with suitable BHP diesel engine through flexible coupling and mounted on common base plate complete with fuel tank inside the acousting system and inbuilt control panel, Governor, Manual & electric Start , Batteries with battry charger, Engine instruments panel,AVM pads, All controls for operationof DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessiblefrom outside. T , 3 Met exhaust pipe, D.G. set shall be mounted under open sky resting on the foundation as per design. 214 SITC of PLC Based Auto main failure (AMF) Panel for 250 KVA DG Set fabricated from CRCA sheet steel 2 mm Thick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, operator interface panel complete in all respect. 215 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 withperforated holes of 12 mm dia ,including all accessories like nut, bolts,reducer, nipple, wire meshed funnel, and Heavy duty weather proof polypropylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, BottomDia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. 216 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less as required. 217 Supply & Laying 50 mm X 6mm sizeGI earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. 218 Providing and Laying cable for DG Set to Panel 240 sq mm X 3.5 core x 2 run( armored aluminium ). 219 Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 - 1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade for 3.5 core X 240 sq mm. 220 SCREENS AND GATES: 221 Rising type thimble mounted CI Sluice Gates of reputed make at IPS 222 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge (working) 223 Stainless steel Manual Bar Screen having bar size 50mmx10mm with (20 mm gaping) at peak load of full discharge( standby) 224 Packing and Frieght 225 Installation, Testing and Commissioning 226 AUTOMATION OF IPS 227 CE& UL certified PLC/RTU with redundant CPU & power supply in IP 54 enclosure suitable to communicate with GSM based modem unit with redundant CPU & power supply with annalog & digital paramter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification including full developed version of scada software with customization of software with laptop/desktop etc to monitor and control the ips from remote places. 228 GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 229 CE/UL certified intellignet Smart Energy Meter 230 Auto phase reversal unit with inbuilt time delay & enclosure (confirm to IEC-60947-1 & IEC-60947-b-1) 231 160 AMP rating 232 Electronic sensor type pressure measuring device suitable for pressure measurements of sewage flow in delivery and common header line. The material of construction of housing and other parts in contact with sewage shall be of stainless steel. These shall be of required protection category and complete with signal transmitting device and digital pressure indicator. 233 CE/UL Certified Surge protector for control panel. 234 CE/UL Certified 7 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 235 Security Survillance IP Camera with recorder 236 Installation, commissiong & testing of above automation work 237 3 month trial run of automation work 238 Expenditure on Operation & Maintenance of IPS during 3 month Trial and Run Period 239 Expenditure onDiesel Consumption of IPS during 3 month Trial and Run Period 240 Expenditure on Electricity Consuption of STP, MPS & IPS as per actual UPPCL bill during 3 month Trial and Run Period
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Uttar Pradesh View Result →
39.
Water Resources and Irrigation #10512072 Price Bid
Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification And Automation With Scada System Including Renovation And Furnishing Of Existing Barrage Control Room At Ramnagar Barrage, Uttarakhand Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification, Automation With Scada System Including Renovation And Furnishing Of Existing Barrage Control Room At Ramnagar Barrage, Uttarakhand Under National Hydrology Project , Supply Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, 7” Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Supply Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Barrage & Head Regulators Complete As Per Technical Specifications. , Supply Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling Required For Monitoring. As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 30M Range For Measuring Barrage Pond Level Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10M Range For Measuring Down Stream Discharge Of Head Regulator Of Main Canal, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Each Plc / Rtu And Instrumentation System, As Per Technical Specifications. , Supply Of Intelligent Field Controller / Rtu As Early Flood Warning Station With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem& Siren At Specified Location, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Supply & Installation Of Air Condition System With Requisite Furniture And Renovation & Furnishing Of Existing Barrage Control Room For Establishment Of Scada Control Room Long With Necessary Electrical Fittings As Per Technical Specification Located At Adwa Barrage, Mirzapur , Supply Of Early Streamer Emission ( Ese ) Lightning Arrestor ( Protection Radius 87 Mtr ) With All Necessary Accessories As Per Technical Specifications , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Interconnection With Relatedplc / Rtu’S, Complete As Per Technical Specification. , Supply, Engineering And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Supply Of Master Server Which Includes Server With Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications. , Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd Along With Dedicated Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Supply Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Supply Of 75” Led Display / Video Wall Based System For Monitoring Of Scada & Surveillance System At Barrage Control Room As Per Technical Specifications , Supply Of Laptops & 4G / 3G Internet Dongle Along With Licenced Versionclient Scada Software For Remote Viewing & Monitoring Of Complete Scada System As Per Technical Specifications. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S Including All Necessary Cabling & Electrical Fittings Complete As Per The Technical Specifications , Supply Of Diesel Generator Set 3Phase 10.0 Kva With 04 Earth Pits For Earthing Along With Accessories Complete As Per Technical Specifications. , Installation, Testing & Commissioning Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 7 Inches Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Installation, Testing & Commissioning Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Installation, Testing & Commissioning Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Installation, Testing And Commissioning & Integration Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, Communication With Nvr Located At Barrage Control Room For Monitoring The Gates Operation Complete As Per Technical Specifications. , Installation, Testing & Commissioning & Integration With Nvr Located At Barrage Control Room Of Pan Tilt Zoom ( Ptz ) Cameras, 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling & Conducting Required For Monitoring. As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 30 M Range For Measuring Barrage Pond Level. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10 M Range For Measuring Dowstream Water Level / Discharge Of Head Regulator Of Main Canal System. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation Testing And Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Instrumentation System, As Per Technical Specifications. , Installation Of Chain-Link Fencing Of ( 5M X 5M ) X 3M Along With Lockable Gates For External Protection Of Monitoring Station For Remote Monitoring & Early Warning Stations, Per Technical Specifications. , Installation Testing And Commissioning Of Intelligent Field Controller / Rtu As Early Flood Warning Station, With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem & Siren At Bareli Town, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Installation, Testing & Commissioning Of Early Streamer Emission ( Ese ) Lightning Arrestorwith All Connectors, Cabling And All Required Accessories Etc As Per Technical Specifications , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc / Rtu’S, As Per Technical Specification. , Installation, Testing, Commissioning And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Installation, Testing & Commissioning Of Master Server With Scada Software Which Includes Server With Server Rack And Industrial Grade Pc With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications , Installation, Testing & Commissioning Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format With Dedicated Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Installation, Testing & Commissioning Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications , Installation, Testing And Commissioning Of 75” Led Display For Monitoring Of Scada & Surveillance System At Control Room As Per Technical Specifications , Charges For High Speed Synchronous Internet Connection ( Min. 8 Mbps Upload And Download Speed ) & Static Ip For Five Years. , Charges For High Speed 4G / 3G Internet Dongle For Laptop With Client Scada Software For Remote Viewing & Monitoring Of Systemfor Five Years. , Installation, Testing & Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S As Per The Technical Specifications , Installation, Testing And Commissioning Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing, Starter Panel, Energy Meter & Cabling Complete In All Respects As Per Technical Specifications. , Five Years Operation & Maintenance And Comprehensive Warranty For Ramnagar Barrage & Head Regulator Scada Based System As Per Price Schedule After Final Acceptance Of Scada & Surveillance System. This Includes Replacement Of Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gprs & Sim Charges For Data Transmission, Maintenance And Other Related Charges. Minimum One Service Engineer Shall Be Placed At Barrage Control Room For Operation Of Scada & Surveillance System. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Start Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Plc / Rtu & Scada Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Uttarakhand View Result →
40.
Drinking Water Supply and Sanitation #10490367 Price Bid
Nit No. 18(21-22)/Cwa(Wns)Ii Hp/Item No. 01 Sitc Of Fume Hood X 1, Body Shower And Eye Shower For Quality Control Laboratory, Haiderpur (Iso-9001-2015 Certified). , Ducted High Performance Fume Hood Specifications A Fume Hood Sometimes Called A Fume Cupboard Or Fume Closet Is A Type Of Ventilation Device That Is Designed To Limit Exposure To Hazardous Or Toxic Fumes In Lab Environment. It Bypasses All Toxic Fumes From Lab By A Duct. Internal Material Of Fume Hood Is Made By 6 Mm Phenolic Resin Laminate Which Has A Very Good Chemical Resistance Properties And Outer Body Also Made By Gi Sheet With Epoxy Powder Coating. The Size Of Fume Hood Varies As Per The Requirement Of User And It Starts From 1200Mm, 1500Mm, 1800Mm And So On. Internal Size Also Varies In Same Manner. Moc Also Can Be Changed As Per The Criticality Of Chemicals That A User Is Using In Their Labs. In Conclusion We Can Shay That Fume Hood Is Safety Equipment Which Is Necessary For A Lab To Make A Healthy Environment. Overall Dimensions With Base Cabinet:1800 Mm W X 1000 Mm D X 2400 Mm H Fume Hood Dimensions: 1800 Mm W X 1000 Mm D X 1555 Mm H Base Cabinet Dimensions: 860 Mm W X 600 Mm D X 655 Mm H With Castors – 2Nos Inside Fume Hood Working Volume: 1740 Mm W X 750 Mm D X 1180 Mm H Bed Size:1740 Mm W X 750 Mm D Quantity: 1. Model - High Performance Fume Hood 2. Design Basis-American Design Standard: Ashrae110-2016 All Tests Including “Tracer Gas Containment Test” Passed. European Design Standard: En-14175- 2003 ‘Inner Plane Containment Test’ Passed. 3. Design Structure-Aerodynamic, Floor Mounted 4. Airflow Type-Low Constant Volume (For A.C. Environment) 5. Colour Combination-(May Select As Per Our Standard Colour List) 6. Powder Coating -Complete Metallic Parts Are Processed With Multi Tank Pre- Treatment And Finished With Highly Corrosion Resistant Kansai Nerolac/Equiv Epoxy Powder Coating With 70 - 80 Microns Thickness. Our Automatic Coating Plant And Fully Conveyorized Ovan Ensures That Coating Surface Get Appropriate Temperature To Bond With The Surface. The Paint Surface Was Tested For Quality And Longevity Out Of Which 1000 Hours Salt Spray Test Is Important Factor. 7. Material Of Construction Of Superstructure-Galvanized Iron (Gi) As Per Is 277: 2003 Standard Of • 1.0 Mm Thickness For All Sheet Metal Paneling • 1.2 Mm For Back Pillars • 1.2 Mm For Front Corner Post 8. Front Top Panel -Easily Openable Hinged Gas Spring Based Top Panel For Easy Access To Flow Control Valve And Electrical Lighting Fixtures For Maintenance. 9. Corner Post -Triangular Profiled Corner Post Is Placed On Lhs And Rhs Of The Fume Hood And It Houses The Utility Line Fittings And Electrical Receptacles. 10. Inside Liner -Chemical & Heat Resistant, Fire Retardant, Smooth Finish, Easily Cleanable Panels Made Out Of Durable Prl Integral Work Walls (6 Mm Thick). Astm Flame Spread Index < 25. 11. Active Kinetics Exhaust System -Interstitial 7-Point Active Kinetics Exhaust System (For Light, Normal & Heavy Fumes) With Baffle To Ensure Rapid Exhaust Of Fumes. 12. Airfoil -Aerodynamic Design, Horizontal Fixed Airfoil Mounted On The Worktop Made Of Ss 304 (1.2Mm) Teflon Coated. 13. Worktop -Chemical Resistant Splash & Spillage Proof Dished ‘Jet Black Granite’ Worktop (18 +1 Mm Thick). Skirting Of 15 Mm From All Sides For No Chemical Spillage. 14. Sink, Water Tap With Drain Arrangement -Worktop Will Have Sink Sealed With Silicon Sealant For Drainage With Water Tap On Left Back Side Of Worktop. Sink Will Have A Trap For Waste Collection. Oval Shaped 100 Mm X 200 Mm Sink 15. Sash (Shutter) -Vertical/Combinational Rising Sash Counter-Balanced With Pulley And Counter-Weight System. Toughened Float Glass Sash (5 Mm Thick). Smooth And Light Sash Operation. Clear Openable Height = 750 Mm. Impact Resistance Of The Sash (Toughened Glass) Is Four Times Higher Than Other Sash Materials (Like Safety Glass And Polycarbonate). Breaking Stress Value For Fully Toughened Glass (Tempered Glass) = 24,000 Psi. • Aerodynamic Sash Handle • Single Finger Movement • Timing Belt For Movement 16. Wet & Dry Services Valves-Remotely Operated Colour Coded Valves For Fine Control Over Utilities (As Per Din 12920 Norms) Total 5 Nos. Service Valves With Flexible Hose With 6Mm Internal Dia, Withstands Up To 5Kgf Pressure (All Lhs) • 1 For Raw Water (Pu) • 1 For Vacuum(Teflon) • 1 For Comp. Air (Pu) • 1 For Chilled Water Supply (Cws) • 1 For Chilled Water Return (Cwr) – No Valve Only Nozzle 17. Maintenace Ports -Openable Top Panel For Easy Maintenance Of Tube Light And Flow Control Valve. Rectangular Service Panel For Maintenance Of Utility Valves And Tubing. 18. Internal Nozzles-Brass Powder Coated Fittings Are Staggered In The Fume Hood To Avoid The Intermingling Of The Flexible Tubes. Also, The Taps Are Tapered In Shape To Use With Flexible Tubing Of Sizes From ¼” To ½” In Dia, To Provide Greater Flexibility To The User. 19. Lighting -Fluorescent Light (40 Watt, 2 Nos.) With Vapour-Proof Fitting For Proper Illumination. Intensity Approx 400 Lux At Worktop Level. Diffused Light Only, No Direct Lighting. 20. Electrical Utilities- 6 Nos. Electrical Sockets ‘North-West’ Make (230 V, 6/16 A, 50 Hz), 6 Nos. ‘North-West’ Make Mcbs. Light Switch On Front Fascia. Cables & Wires ‘Fire Retardant Low Smoke’ Grade. Emergency Stop Push Button For Fume Hood Switches. 21. Cable Entering Port -Dia 100 Mm Cable Entry Tunnel From Fume Hood Front Post To Inner Liner. With A Plastic Cover. For Easy Access Of Cables From Fume Hood To Electrical Sockets. 22. Chemical Storage Base Cabinet (Ventilated & On Castors) Base Cabinet Will Be Ready To Receive The Fume Hood At Its Top. It Will Have Following Features: 1) Completely Made From 1Mm Thick Gi Sheet With Highly Corrosion Resistant Epoxy Powder Coating,60-80 Microns Thickness. 2) Cabinet Integral Work Walls Will Be Special Chemical & Heat Resistant, Smooth Finish, Easily Cleanable Panels Made From Durable Prl Sheets. 3) Two Exhaust Ports Connected To The Fume Hood Exhaust System Internally. 4) One Removable Horizontal Partition To Store Chemicals. 5) Pp Trays For Chemical Storage. 6) Cabinets On Castors. 7) Roller Catch Of “Hafele”– Germany” Make For The Base Cabinet Doors. 8) Polyamide Hinges From Outside Of Base Cabinet.Overall Dimensions: 860Mm(W) X 600Mm(D) X 655Mm(H) With Castors – 2Nos. 23. Apparatus Holding Grid (Lattice Assembly)- A Grid Made Up Of Epoxy Powder Coated Rod (Dia. 12.7 Mm) To Hold The Apparatus. It Will Cover The Entire Length Of The Fume Hood And Will Be Built-In At Fume Hood Backside. Installed At The Distance Of 150 Mm From Backside Of Fume Hood. 24. Air Flow Meter -This Device Is An Accessory For Fume Hood To Indicate The Approximate Face Velocity Of Airflow With Primary Purpose Of Warning When A Low Flow Condition Occurs. Red & Green Leds Correspond To Low & Normal Flow Rates. When Flow Decreases From Normal To Low, An Audible Alarm Will Also Actuate Requiring Manual Acknowledgement For Silence. Digital Display Of Face Velocity In M/Sec Or Fpm. On Screen Display For Safe And Alarm Conditions With Audible Alarm And Led Indication. Push Button Calibration And Configuration. Plug-In Connections For Power Supply And Airflow Sensor 25. Temperature Indicator -Size 48 X 48 X 110, Mm (Panel Cutout - 44 X 44 Mm). Accuracy ±0.25% Of Reading ±1 Lsd, ±1°C Supply Voltage 85 To 264 V Ac, 50 / 60 Hz User Interface Display: 2 Rows Of 3-Digit X 7 Segment High Intensity Led Upper Row : Process Value For Pid 1 Lower Row: Process Value For Pid 2 Key Board: 3 Front Panel Keys For Settings 26. Level Adjusting Screws -Made Of Ss Bolts To Adjust The Fume Hood Level By ± 10 Mm 27. Exhaust Port -Unique Exhaust Port Design Ensures That The Fumes Will Be Exhausted Smoothly Without Any Turbulence At The Exhaust Port. Also, It Ensures Low Noise Level. 28. Flow Control Valve -To Regulate Airflow. 29. Noise Level - < 70Db At 1 Meter From Fume Hood. 30. Sash Lock -At 450 Mm To Restrict Movement Of Sash 31. Face Velocity -Should Pass Ashrae 110: 2016 Test At 60 Fpm 32. Drawer -Drawer Within The Fume Hood Structure To Keep Stationery 33. Pull Out Tray -For Keeping Notebook 34. White Board -300 Mm X 450 Mm White Board For Writing Centrifugal Blower: (For Air Suction In Cluster Of - Nos. Of 6 Ft. Fume Hood & - No. Of Spot Extractor) Silent Pp + Frp High Efficiency Remote Blower, Consisting Of Continuous Rating Motor And Chemical Resistant Impeller. It Satisfies International Safe Velocity Norms. 1. Construction-Sisw Type, Chemical & Heat Resistant Pp + Frp Blower With Aerodynamically Balanced Pp Impeller, With Drain Plug. 2. Air Suction Capacity -2400 Cfm Confirming To International Face Velocity Norms And As Per Safe Fume Hood Airflow Pattern. 3. Motor-‘Crompton / Lhp/Other Reputed’ Make, --Hp Motor 3 Phase Tefc, Ip 55, Class F, Continuous Rating. As Per Is 325. 4. Drive -Direct Drive Ducting: Chemical Resistant Pp + Frp (3Mm + 2Mm) Rigid & Flexible Ductwork From Fume Hood To Exhaust Stack Point With Weatherproof Canopy. Total Ducting With Horizontal, Vertical Members, Flanges, Bends, Bracketed Supports And Gooseneck Exhaust Stack. Installation : It Will Be Carried Out By Skilled Team With Ductwork Design, Fitting, Fixing Of Blower, Commissioning & Testing Of The Same At A Fixed Extra Cost Testing: All Fume Hoods Should Be “Factory Tested” As Per Ashrae110:2016 Face Velocity Norms. Also, “Onsite Validation” To Be Carried Out To Ensure Working Of Fume Hood As Per International Norms. “Tracer Gas Containment Testing’ Can Be Carried Out At Vendor’S Factory. , Supply Of Body & Eye Shower With Glass Bathing Enclosure And Ss Frame The Vendor Shall Provide Overhead Safety Shower Integrated With Eye Washer And Fume Hood With Installation And Also Do The Necessary Civil And Well As Wiring Work In A Scientific Required Manner. Specifications For Safety Shower Enclosed In Glass Shower Enclosure There Shall Be Safety Shower Cum Eye Washer For Decontamination Of Body In Case Of Any Toxic Or Chemical Contamination. It Shall Be Dual Operation With Hand Or Foot. The Same Will Be Enclosed In Glass Enclosure With Proper Water Supply System And Drainage System. The Height Of Shower And Bowl Will Be Adjustable. Material Of Construction: Shower: Ss 304 Basin Bowl: Ss 304 Shower Foundation: Ss 304 Filter Screens: Ss 304 Activation Push Plates: Ss 304 Piping: Ss 304 Waste Strainer: Ss 304 Water Flow Atomizer: Abs Dimensions: A. Total Height: 2445+-30Mm B. Shower Height 2100-2400Mm C. Eyewash Height 850-1150Mm D. Shower Bowl: 10.5/8” E. Eye Water Bowl: 11” F. Piping: ¾” Wall Thickness 2.5-3Mm G. Inlet: 1” Bsp, Outlet ¾” H. Ss Push Plate: 2 Mm Thickness I. Ss Pull Rod: 6 Mm Thickness J. Foundation Diameter: 165 Mm Water Flow: 1. Inverted Directional Laminar Flow. 2. Protects Nasal Cavity. 3. Filter Capsule Prevents Water Clogs For Uninterrupted Water Flow. 4. Attached Dust Cover (Ppcp). 5. Provided With Filter Capsule With Flow Controller (Pressure Range: 2.1-3Kgf/Cm2). 6. Provided With Ss Filter Screen To Protect From Unwanted Impurities. 7. Additional Flow Controller For Pressure Higher Than 3Kgf/Cm2 8. Under Conditions Of Adequate Pressure, Minimum Flow 11 L/Min. Receptor Bowl: 1. Straight Edged And Raised Basin To Prevent Splashing. 2. Ss Bowl Valve Equipped With Ss Ball And Steam Ss .304 (1/2 For Eyewash, 1For Shower). Drainage System: There Will Be A Rectangular Ss Drain Platform With Perforation. The Same Will Be Minimum 60% Of The Area Of The Enclosure Platform. This Is Need In An Scientific Manner To Flush Out The Water From The System In Seconds. Glass Enclosure: The Above Safety Shower Cum Eye Washer Will Be Enclosed In U Type-Glass Enclosure So At The Time Of Decontamination No Spill Spread Takes Place. The Glass Enclosure Will Have Tiles Of Good Quality At The Back Side And Three Side Glass That Include Gate (U Type). All Glass Will Be Toughened. Glass Thickness: 10 Mm Toughened (Tufnik Or Jaguar) Glass Door: 2135 Mm X 750 Mm (Minimum) Glass Enclosure Dimensions: 1066 Mm Width X 1220 Mm Depth X 2133 Mm Height Fittings, Hinges And Towel Bar Handle, L Connectors: Tufnik Or Jaguar Shower Cubical Size: As Per Site Requirement Over-Head Tank: 1000 Ltr (Syntex) Water Supply Fittings: Will Be Pp (Astral) Drain Pipes: Pvc (Astral/Prince) Installation Of Safety Shower And Fume Hood With Ducting, Electric Connections And Plumbing And Required Civil Work: It Will Be Carried Out By Skilled Team With Ductwork Design, Fitting, Electrical Work (All Wiring Will Be In The Concealed Conduit), Required Civil Repairs, Commissioning & Tetsing Of The Same. (Vendor May Visit The Site). The Whole Work Will Be Done Scientifically Keep In View All And Future Requirements Of Both The Systems. Between The Two Systems I.E. Safety Shower And Fume Hood There Will Be Backlit Glass/Acrylic Djb Logo And Lab Certifications. Civil Work:Demolition Of Existing Slab And Back Wall Tiles, Re-Plastering Of Back Wall And Tile Work. 10 X 18 Including Corner Of Another Wall (180 Sq Feet). Platform 10 X 5 Of 2 Height Where Safety Shower And Fume Hood Will Be Installed. Vitrified Tile Of Best Quality On Floor 12 X 6. There Will Be Black Granite On The Platform Front(12X2). The Plumbring Work That Include Installation Of 1000 Ltr Water Tank On The Roof Of The Lab, Connection Of Water Of The Systems, And Drainage From Safety Shower To The Drain As Per Specifications. , Demolition Of Existing Slabs, Tiles, Sink, Floor Tiles, Cupboard, Electrical Fixtures And Plumbing Fixtures , Installation Of Body Shower And Eye Shower With Glass Bath And Ss Frame , Installation Chemical Styorage With Fume Suction System Including Carriage. , Fixing Of Eye Shower With Complete Plumbing Work To Maintain Pressure From Djb Mainline Administration Block With Overhead Tank Including All Necessary Work. , Fixing Of Floor Tiles, Wall Tiles, Complete Electrical Work And Civil Cutting Of Window, Manhole With Cover Frame And All Other Necessary Jobs. , Testing & Commissioning With 365 Days Of On-Site Warranty
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
41.
Public Administrative Department #10396542 Price Bid
Tender For Repair of water tank and any other work under Nagar Panchayat Faridnagar - Providing and laying in cement concrete 1:6:12 (1 cement :6 fine sand :12 graded brick ballast) and curing complete,including cost of form- work,in foundation and floors. 2 Class M-150 brick work in 1:4 cement coarse sand (of 2.20 fineness modulus) mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 3 12 mm thick plaster with cement and fine sand of 1.25 fineness modules in 1:4 over brick work minimum thickness not to be less than 1cm. Including supply of all materials, labour, tools & plants etc. required for proper completion of the work. 4 Cement Concrete with 2 cm. gaugestone ballast, coarse sand and cement. In proportion of 1:2:4 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 5 M.S. (tor steel or plain) in Plain work such as R.C.C. or R.B. work including bending for proper shape as necessary inclding bending for proper complition of the work and including supply of all steel & wastage, bend, hooks and authorised overlapping hall be measured. 6 R.C.C. Work with cement, approved coarse sand & 2 cm guage approved stone grit in proportions of 1:2:4 in lintels of door & windows excluding supply of reinforcement and its bending. But including its fixing and binding wire and including necessary centering and shuttering etc. and supply of all materials,labour, tools & plants etc. required for proper completion of the work including cost of binding wire. The rate excludes making of drip course which shall be paid extra. 7 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of REPAIRS TO BUILDING 1140 Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 8 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 9 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 10 Finishing walls with weather coat by premium acrylic exterior paint applied @1.67 ltr/10 sqm asian or berger brand of approved make and quality on wall with two or more coat to give an even shade including a priming coat with cement primer of approved brand and manufecturer exterior primer applied @2.20kg/10sqm after thoroughly brushing the surface etc complete. 11 Dismantling of old damage jaali with frame and supply and fixing of new ventilator jaali of OHT including repair of ventilator and fixing the same properly including supply of all labour, TP etc required for the proper completion of work.. 12 Removal of old damaged Man hole cover and supply and fixing of 60X60 cm size fabricated M.S. over with frame consisting of 50X50X6 mm angle , iron frame and over of M.S sheet of 3 mm welded in cover with hinge & locking arrangement and paint with anticorrosive paint and fixing the same at top dome of OHT and also including supply for all material , labour , T & P etc. required for the proper completion of work . 13 Providing and fixing hand rail of G.I. pipes 40 mm dia approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 14 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing balcony railing and staircase railing including applying a priming coat of approved steel primer on MS tube 12SWG as per direction of Engineer In - charge. 15 Water level indicator 16 Lightening conductor : 17 Cleaning & disinfection of OHT through six stage scientific method of high pressure cleaning, anti bacterial spray and UV radiation etc. 18 Construction of Embankment with material (Earth) obtained from Borrowpits cartage from 8 Km.With all lifts and leads, transporting to site, spreading ,grading to required slope and compacting tomeet requirement of table 300-2 19 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material byippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as perpecifications and directions of Engineerin- Charge With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 complete as per clause 401. 20 Laying & supplying of 80 mm precast cement concrete I- shape Interlocking paver blocks with top layer of minimum 8 mm thickness having plan dimesion 200X(160+120mm)OP Cement,smoot high gloss finish skid resistant manufactured from rubber moulds through vibro-compression mechanism.The compressive strength of concrete paver block shall not be less than 30 Mpa (m -30) and weight 5 kg per no. conferming to IS:15658-2006 including cost of material ,labour ,T &P etc.required for proper completion of the work as directed by Egneer -in charge .But excluding up TT which shall be paid extra as rules as per item no.9 (RED color (High Quality plgment/lanxess Byer chemical) 21 Add Gst 18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
42.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
43.
Educational and Research Institute #10365642 Price Bid
Tender For Comprehensive Annual Operation And Maintenance Works & Services At Central University Of Rajasthan.; 1 Comprehensive Annual Operation and Maintenance Works & Services 2 SH-I (a) Deployment of Maintenance Gang for day to day Civil Maintenance work at CURAJ 3 SH-I (b) Operation And Maintenance Of 750 KLD Sewerage Treatment Plant at CURAJ 4 SH-II (a) Electrical & Mechanical Preventive And Day To Day Maintenance Works, Annual Operation, Repair, Maintenance And Periodic Servicing Works Of Pump Houses And Annual Electrical Works At CURAJ 5 Annual preventive and day to day maintenance, to upkeep all the electrical internal & external installations, fittings, fixtures, wiring, Lights, Fans, Geysers etc. functional in the CURAJ campus, for all days in a month, including Sundays and Holidays, including manpower, labour, machinery, general maintenance items, tools & tackles for all deputed staff, safety tools for LT & HT power supply, various type of ladders/tipaya/chopaya etc. as required on site, complete in all respects, as per standard practice. Indicative items are as under: • Wiring/Cabling.• Metal/PVC boxes.• Switches, sockets and accessories of different ratings.• 01phase/03 phase power points & circuits.• 01/03 phase Energy Meters.• Light points/ Fan pts/ Exhaust Fan pts/Call bell pts. etc.• All type of indoor and outdoor lights (conventional/LED/HPSV/MVSV etc.) fittings.• All type of fans (Ceiling/Exhaust/pedestal/wall).• HVLS fans.• Water heaters.• Auditorium stage lights.• Air curtains and electric fly catchers.• Rising mains bus trunking and overhead bus bar of different ratings.• Sandwich rising mains with aluminium bus bar of different ratings.• Switch, disconnector, SFU and MCCB of different ratings.• MCBs, Isolators, RCCBs and MCB DBs of different ratings.• Cable and Boxes of different sizes.• Brass compression glands of different sizes.• Aluminium lugs of different sizes.• HT/LT Cable fault detections and jointing kits.• Overhead electric line.• Road lights.• Lightning arrester and earthing system.• All Electrical indoor and outdoor panels and panel rooms of all buildings.• Maintenance of records etc. and as per tender document. 6 Comprehensive Annual Electrical Operation, Repair, Maintenance and Periodic Servicing Works of pump houses and other water & booster pumps/motors/starters along with associated panels and accessories for all days in a month including Sundays and Holidays, including manpower, machinery, spare parts, consumables, tools & tackles for all deputed staff, safety tools for LT power supply, ladders, ropes etc. as required on site, complete in all respects.Note: Tentative quantity of motors & pumps of different ratings is 30. 7 Providing of uniform to all the deputed staff with reference to (a & b) above, as prescribed by the University and as per tender document. 8 CPWD DSR (E&M) 2022/Chapter-01: Wiring.The bidder has to quote the rates above / below / at par on DSR (E&M) 2022 rates (including all) considering estimated cost of work Rs. 5,00,000/- 9 CPWD DSR (E&M) 2022/Chapter-02: MCCB, MCB, DBs.The bidder has to quote the rates above / below / at par on DSR (E&M) 2022 rates (including all) considering estimated cost of work Rs. 1,00,000/- 10 CPWD DSR (E&M) 2022/Chapter-05: EarthingThe bidder has to quote the rates above / below / at par on DSR (E&M) 2022 rates (including all) considering estimated cost of work Rs. 1,00,000/- 11 Detection of fault in underground electric Low Tension (LT)/High Tension (HT) cable incl. fault detection machine charges, digging & labour charges etc. complete in all respects as per standard practice. 12 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor LT cable of 1.1 KV grade as required. 13 3½ X 25 sq. mm 14 3½ X 35 sq. mm 15 3½ X 50 sq. mm 16 3½ X 70 sq. mm 17 3½ X 95 sq. mm 18 3½ X 120 sq. mm 19 3½ X 150 sq. mm 20 3½ X 185 sq. mm 21 3½ X 240 sq. mm 22 3½ X 300 sq. mm 23 3½ X 400 sq. mm 24 4 X 16 sq. mm 25 Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor HT cable of 11 KV grade as required : 26 70 sq. mm 27 120 sq. mm 28 185 sq. mm 29 240 sq. mm 30 300 sq. mm 31 400 sq. mm 32 General inspection & patrolling of about 10 km long overhead HT/LT lines feeder wise for identification of maintenance work to be carried out i/c strengthing of cross arms with clamps including tightening of nut bolts, removal of birds nest and foreign material from line along with tree/bush trimming under these lines. (to be carried out before starting of summer season and as per the requirement). 33 Annual Servicing of Fans (Ceiling/Exhaust/Wall/Pedestal etc.) installed in various buildings of the University i/c checking the unit with accessories for functionality tests, replacement of nut-bolts & locking pins/clips wherever reqd, oiling/greasing, cleaning, pasting of service/repair slips on fan and any other minor repair works required on site i/c labour, tools & takels charges as per standard practice and directions of EIC. Note: 1) This work also includes replacement of spare parts of fans like condensors, regulators, fan hooks as required during servicing and these spare parts will be provided by the University.2) This work excludes all major repair works like rewinding, replacement of bush/bearing etc. 34 Copper rewinding of existing burnt fans (Ceiling/ Exhaust/Wall/Pedestal Fans) under buyback of old copper incl. handling charges etc. as per standard practice. 35 Replacement of parts like bush/bearing etc. with new one of same size/rating under buyback of faulty one as per standard practice incl. handling charges. 36 Repairing of rotor/stator/shaft etc. of fans as required as per standard practice incl. handling charges. 37 Comprehensive AMC Work of Online UPS(s) of different ratings installed in various buildings of CURaj 38 Comprehensive AMC Work of Online UPS(s) of different ratings installed in various buildings of CURaj, including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects excluding replacement of batteries.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 39 14 Nos. 1 kVAOnline UPS 40 08 Nos. 2 kVA to 3 kVA Online UPS 41 08 Nos. 5 kVA to 6 kVAOnline UPS 42 02 Nos. 10 kVA Online UPS 43 06 Nos. 15 kVA to 20 kVA Online UPS 44 02 Nos. 40 kVA Online UPS 45 Replacement of following capacity faulty/dead SMF rechargeable batteries with new batteries of same rating/capacity along with connections, testing and commissioning etc. as required on site as per standard practice, under buyback offer. Make: Exide/Amaron/Luminous/HBLWarranty:minimum 02 years onsite or as per OEM, whichever is higher. 46 18 AH, 12 V 47 26/28 AH, 12 V 48 42/45 AH, 12 V 49 65 AH, 12 V 50 75 AH, 12 V 51 120 AH, 12 V 52 150 AH, 12 V 53 Comprehensive AMC Work of 86 Nos. Water Coolers of 150 LPH capacity each, installed in various buildings of CURaj 54 Comprehensive AMC Work of 86 Nos. Water Coolers of 150 LPH capacity each, installed in various buildings of CURaj, including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects.Note: This work includes general R&M on monthly basis, preventive R&M on quarterly basis, annual servicing and unlimited breakdown calls through qualified & experienced persons. 55 Repairing of 45 Nos. faulty Water Coolers of 150 LPH capacity each, installed in various buildings of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 56 SH-II (d) Comprehensive AMC Work of HVAC System (Ductable / VRV-VRF / Cassate / Split / Tower / Window Type Air Conditioners and ETAC System) installed in various buildings of CURajComprehensive AMC Work ofHVAC System (Ductable / VRV-VRF / Cassate / Split / Tower / Window Type Air Conditioners and ETAC System) installed in various buildings of CURaj, including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice and directions of Engineer-in-Charge.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 57 100 hp rated inverter technology based VRV/VRF type Air Conditioning System installed in CIL Building. Make: Hitachi 58 40 hp rated inverter technology based VRV/VRF type Air Conditioning System installed in VCS, Admin Building. Make: Hitachi 59 04 Nos. 11.0 TR capacity Ductable Air conditioning units with Scroll Compressor with R 410 A Refrigerant, vibration isolators etc. complete. Make: Hitachi 60 03 Nos. 5.5 TR capacity Ductable Air conditioning units with Scroll Compressor, R 410 A Refrigerant, vibration isolators etc. complete. Make: Carrier 61 03 Nos. Ceiling-mounted 3.0 TR Cassette Air Conditioning units complete. Make: Bluestar 62 400 Nos. Window/Split/Tower type air conditioners. 63 02 Nos. 30000 CFM, Air ducting system (ETAC) 64 04 Nos. 28000 CFM, Air ducting system (ETAC) 65 02 Nos. 10000 CFM, Air ducting system (ETAC) 66 02 Nos. 4000 CFM, Air ducting system (ETAC) 67 Repairing of faulty 100 Nos. Split ACs, 10 Nos. Tower Air-conditioners and 01 No. 5.5 TR Ductable AC, installed in various buildings of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 68 SH-II (e) Comprehensive Annual Operation, Repair and Maintenance of 04 Nos. 11/0.433 kV electric sub-stations and 05 numbers DG Sets at CURaj. 69 Comprehensive Annual Operation, Repair and Maintenance of 04 Nos. 11/0.433 kV electric sub-stations and 05 numbers DG Sets along with associated panels etc. through OEM/Authorized Service Agents of OEM only, including manpower for operational purpose, labour, machinery, spare parts, Control Panel/DG Set Batteries, consumables, tools & plants etc. complete in all respects, as per standard practice and directions of Engineer-in-Charge.Note: 1) This work includes operators in all three shifts on 24*7*365 basis at each ESS.2) This work includes general R&M on monthly basis, preventive R&M on quarterly basis, annual servicing i/c all B/C/D checks and unlimited breakdown calls through qualified & experienced persons, as per OEM’s standard guidelines & service manuals. 70 SH-II (f) Comprehensive Annual Operation (in general shift), Repair and Maintenance of 14 nos. Johnson make, machine room less passenger lifts at CURaj. 71 Comprehensive Annual Operation (in general shift), Repair and Maintenance of 14 nos. Johnson make, machine room less passenger lifts along with associated panels etc. through OEM/Authorized Service Agents of OEM only, including manpower, labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice.Note:1) This work includes one lift operator in general shift on 24*7*365 basis in Admin Building.2) This work includes general R&M on monthly basis, preventive R&M on quarterly basis, annual servicing and unlimited breakdown calls through qualified & experienced persons, as per OEM’s standard guidelines & service manuals. 72 SH-III Comprehensive Annual Repair & Maintenance Work of Fire Hydrant System and Fire Alarm System installed at CURaj. 73 Comprehensive Annual Repair & Maintenance Work of all Fire Hydrant System installed in various building of the University (tentative buildings = 30 nos.) as specified in Schedule of Work, including manpower, labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 74 Comprehensive Annual Repair & Maintenance Work of all Fire Alarm System and associated equipment installed in various building of the University as specified in Schedule of Work, including manpower, labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 75 Repairing of existing non-functional Fire Hydrant System including associated equipment, installed in B1 to B7 Hostel buildings, KV Building and B/C/D type Staff Quarter Blocks of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 76 Repairing of existing non-functional Fire Alarm System including associated equipment, installed in various buildings of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 77 SH-IVComprehensive Annual Maintenance Contract for RO Plants/Purifiers. 78 The scope of work includes comprehensive annual maintenance and servicing of RO Plants/Purifiers and submitting a report after every visit. The scope of work includes checkup of each Unit/system and general cleaning, chemical cleaning of cartridge, if required, replacement of all type of membrane, all type of filters, all pipes, S.V., TDS Controller, all type of sensors, pump etc. as per requirements of the University during the CAMC Period. 79 Supply and Installation (under buy back) of Reverse Osmosis Plant of 50 LPH Capacity Make Eureka ForbesNote: Old Reverse Osmosis Plant of 50 LPH Capacity - Make Eureka Forbes will be the property of the Contractor. Hence contractor may be advised to quote their rates accordingly. 80 SH-VComprehensive Operation and Maintenance of IT Works. 81 Comprehensive Operation and Maintenance of installations IT Works (Operation & CAMC of Audio & Video Conferencing System, Networking items for LAN and Wi-Fi systems like Switches, Active & Passive network components, Smart class rooms Equipments including PA systems, Hardware and software maintenance of Computers, Laptops, Printers, Projectors, Servers), CCTV Systems. as per the details given below: 82 Hardware Items 83 Laptops : 84 Desktop System: 85 Server: 86 Printers: 87 LCD Projector: 88 CCTV System 89 IP Camera 90 DVR Camera 91 Switch (24 port) 92 Switch (8 port) 93 Switch (4 port) 94 42 Screen 95 32 Channel NVR 96 8 Channel NVR 97 4 Channel NVR 98 Surveillance Hard Disk 10 TB 99 Surveillance Hard Disk 4 TB 100 Surveillance Hard Disk 2 TB 101 Biometric Access Control Systems 102 Face Biometric Machine 103 Voice System 104 IP-PBXMachine 105 IP Phone 106 IP Phone DSS KEY 107 Data Networking System 108 Switch(48 Port) 109 Switch (24 Port) 110 Core Switch 111 LAN points 112 Audio Video Conferencing System 113 Group Video Conferencingdevice including camera, speakerphone with USB plug-and-play connectivity 114 PTZ Video Conferencing Camera 115 Smart Classrooms System including PA System 116 Smart Classroom equipped with, interactive screen 75/86 inch, audio systems, digital podium with mini PC, PTZ cameras and other related items 117 SH-VI Comprehensive Maintenance of Horticulture and operation & maintenance of Drip Irrigation System. 118 Horticulture Manpower in General Shift in all days except Sundays and holidays (Unskilled). All tools tackles shall be arranged by contractor within its quoted rates.• Complete maintenance of Trees, Plants and peripherals, shrubs, hedge, lawns, (Including cricket ground, hockey ground and football ground etc.) cemented potted plants, flower beds, creepers etc. within the campus of the Central University of Rajasthan.• Maintenance includes weeding, pruning, gap filling, watering, mowing of lawn, hoeing, hedge-clipping, application of insecticide & pesticide, top dressing of lawn with good earth and manure including other maintenance work as directed by the University from time to time.• Fertilizers, Manures, plant protection materials etc. will be provided by the contractor nothing extra shall be paid in this regard.Maintenance of Drip Irrigation System, (water sprinkler system installed at cricket, football and hockey grounds and another places of the University etc.) periodical checking of the system cleaning, oiling, greasing, routine maintenance, realignment, necessary safety arrangements & repair/ replacement of consumables such as Super flow screen filters, Gravel filters, Pressure relief valve, Non return valve, stainless steel pressure gauges,by pass valve PP, PVC control/ball valves, sub main flush valve, Reinforced nylon air release valve CPVC gate valves, super flow disc clean filters, PVC pipes and fittings etc. as per direction of Engineer-in-charge. This shall include all cost involved in maintenance except for electricity for operation, which shall be provided by the University free of cost. 119 SH-VIIMechanized Housekeeping Services, Garbage Collection & Disposal Services, and Pest Control Services at CURAJ. 120 ProvidingMechanized House Keeping Service include machine enabled cleaning, sweeping, wiping, dusting, moping, freshening, garbage collection, segregation & disposal, vacuum cleaning, scrubbing and any other similar tasks as assigned by CURAJ authorities from time to time.Consumable, like duster, Soap, chemicals, wipers, Phenyl and other cleaning materials for toilets and floor required as indicated in list under the scope of work etc.All façade glass should be cleaned once in a month including glass doors and windows.Providing pest Control Services, Rodent Control Services, Fogging & Fumigation against mosquito & larva, Fly management services, termite treatment etc. as per tender terms and conditions and directions of the University. 121 Termite Treatment: Termite treatment in the University based on IS:6313(Part-3)-1981 specification which consists of creating uninterrupted chemical barriers inside and all around the building. The treatment should be drill holes of 6mm as close as possible to the plinth, walls, junctions of the walls at an interval of 6 inches enough to reach the soil below 6 inches deep. Then chemical emulsion should be injected into these holes, which should be subsequently sealed using white cement match with floor colour all complete , The wall should be spray the chemical emulsion up to roof height wherever required complete. 122 SH-VIII Hiring Manpower with fixed remuneration through outsourced agency at CURaj. 123 Service charges per month per person(To be quoted for deciding the lowest responsive bid to award the work)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
44.
Public Administrative Department #10363312 Price Bid
Tender For Construction Of New Office Building Of Municipal Board Nawa - CIVIL WORKSClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 3 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 6 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (UNDER FLOOR) 8 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (FLOOR UNDER FOOTING AND FOUNDATIONS 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 12 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 15 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 17 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 18 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 19 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 20 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 22 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 23 Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry 25 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 26 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 27 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 28 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 29 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 30 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat including scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns. 31 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 32 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 33 Making grooves as per design in plaster 10mm to 20mm wide. 34 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.Size 600X600mm 35 size600 mm X 1200mm 36 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 37 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 39 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 40 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 41 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 42 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. 43 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Red1501 Cm2 to 3600 Cm2 Tiles 44 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding 45 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 47 Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 48 Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : ISI 9 mm teak ply one side BWR 49 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E 50 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Commercial Veneer both side 51 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 52 Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica 53 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 54 Providing and fixing fully panelled /partly panelleddouble leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure ‘A’ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces : 35 mm thickGhana wood grade I 55 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 56 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of acCumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. (Insert 6mm tougend glass) 57 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shuttershall be made of 39w x 69h mm Extruded 3 box multi-chamberUPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. (Insert 6mm tougend glass) 58 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) 59 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness 60 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 61 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 62 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 63 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 64 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 65 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40mm wide and 4mm thick 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 67 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 68 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 69 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/Sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per 70 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 71 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 72 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 73 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 74 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: (Size 580x440 mm.) 75 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: :PVC with PVCbend as per IS : 7231 . 76 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 630 mm x 500 mm dia for counter top 77 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick 78 Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 79 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 80 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 81 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:15 mm dia nominal boreB Class 82 25 mm dia nominal boreB Class 83 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15 mm dia nominal boreA Class 84 25 mm dia nominal boreA Class 85 50 mm dia nominal boreA Class 86 Concealed pipe in wall including painting with anticorrosive bitumen paint 15 mm dia nominal boreB Class 87 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 88 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 89 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. 90 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 91 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. 92 Gun-metal 25mm nominal bore. 93 Gun-metal 50mm nominal bore. 94 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 95 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig1000 Lt. Capacity 96 500Lt Capacity 97 Hoisting Charges for each floor :For ITEMS 2.26.1 TO 2.26.4 98 For ITEMS 2.26.5 TO 2.26.8 99 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant110mm dia 100 160mm dia 101 P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincludingjoining the pipe with solvent cement rubber ring and lubricantCoupler (socket)75mm dia 102 110mm dia 103 160 mm dia 104 Reducer 110 X 75 mm110mm dia 105 160 mm dia 106 Plain Tee75mm dia 107 110mm dia 108 160 mm dia 109 Door Y110mm dia 110 160 mm dia 111 Bend 45110mm dia 112 160 mm dia 113 Bend 87 .5110mm dia 114 160 mm dia 115 Door Bend (Top Side110mm dia 116 Vent Cowel110mm dia 117 P- Trap110mm dia 118 Gully trap110mm dia 119 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 120 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M 121 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 122 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) 123 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia 124 110 mm dia 125 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia 126 110mm dia 127 Bend 87.5 Dg.75mm dia 128 110mm dia 129 Bend 45 Dg.75mm dia 130 110mm dia 131 Door Bend 87.5 Dg.75mm dia 132 110mm dia 133 Single Y75mm dia 134 110mm dia 135 Socket Plug75mm dia 136 110mm dia 137 Pipe Clip75mm dia 138 110mm dia 139 Nahani trap with jali 4110mm dia 140 Vent Cowel 110mm dia 141 P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:Size 450x350mm 142 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 143 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth 144 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 145 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 146 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 147 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 148 Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactorto achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] includiong with all lead 149 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 150 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 151 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.200 mm nominal bore 152 Diameter 900 mm+C159Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. 153 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 154 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 155 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 156 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm 157 Size 3 to 5 mm 158 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 159 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200 mm Nominal Bore. 160 Supply and Fixing of Big steel Almirah overall size of916mm (W )x486mm (D )x1980 mm(H) with weldedconstruction. It should have the shelf thickness of 0.7mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high y eld strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting .Itshould also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated. Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape,design,type by engineer in charge. 161 Supply and Fixing of small steelAlmirah overall size of 760mm (W )x455mm (D )x1325 mm(H)with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a 2 Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting.It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated.Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape, 162 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning support at back and bottom supported by steel frame 3 2mm thick,powder coated round pipe with full armwooden handles onsides and other fittings as per direction of enaineer in charae. 163 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning 4 support at back and bottom supported by steel frame2mm thick,powder coated round pipe without woodenhandles as per approved colour, shape,design,type by 164 Providing and supplying Officer high back Chair, The seat and back are made up of 1.2 cm thick hot pressed plywood, upholstered with fabric and moulded Polyurethane foam with PVC lipping all around.The back foam is designed with contoured lumbar support for extra comfort. BACK SIZE:65.0cm.(W) X 71.0cm.(H) SEAT SIZE:65.0cm. (W) X 65.0cm.(D) andreinforced with M.S. insert. The armrests are scratch and weather resistant. The armrests are fitted to the seat with seaUarmrest connecting strip assembly made of steel.The center pivot mechanism Is designed with the followingfeatures:360 revolving type.Tilt tension 5 adjustment. Upright locking.The pneumatic height adjustment has an adjustment stroke of 12.5 cm..The pedestal Is made of HR steel and fitted with 5 nos.twin wheel castors (castor wheeldia. 5.0cm.). The pedestal is covered with a P.P moulded cladding for modem and aesthetic looks.The pedestal is 65.0 cm. pitch-centre dla.(75.0 cm with castors). The twin wheelcastors are injection moulded In 30% Glass Filled black Nylon, as per approved colour, shape,design,type by engineer In charge. 165 Providing & Supplying table or size 1500mmx900mmx750mm, Top should be nnished with 18mm MDF Bos:d post formed Both side with 0.6mm laminate of approved make & design & with appropriate balancer on the bottom or the top. All verticals supportsincluding Modestypanel should be of 18mm prelaminated MDF Board with 2drawers & 16 Swing door per approved design.The drawers to beprovided with ai:proved handles and fixed on Telescope channels.AppropriateEdge Bendings to be provided where necessary with PVC beading 2mm thick to be provided. Footrest to be provided with 1Bmm MDF prelaminated board of the same color code.P&F PVC wire managers capslo be provided on the table top, as approved colour,shape, design,type by engineer In Charge 166 Providing & Supplying side table of size 900mmx450mmx750mm. Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate oras same as the Table,approved make & design & with appropriate balancer on the bottom or the topAllvert icals supportspanel should be of 1Bmm prelaminated MDF Board. Having 2Drawers & 1Swing7 door CPU unit. Keyboard tray, with mouse rest to beprovided.Appropriate Edge Bendings to be provided where necessary with PVC beading 2mm thick to be provided as per design.The drawers to be provided with approved handles and fixed on Telescope channels.P&F PVC wire managers caps to be provided on the table top, as per approved colour, shape,design, 167 Providing and $Upplylng table of size 1200mmX 750mmX750mm high as per design. The table top should be finished with 0.6mm thick laminated postrorming on 18mm thick MDF board.The 3 drawer unit (provided withlocking mechanlsm)and all other8 exposed vertical supports should be finished with steel members or approvedshade,colour and make.Appropriate moulding/edge bindingto be provided where necessary with PVC beading 2mm thick lo be provided as per approved colour, shape,design, 168 Providing & Supplying Computer table of size 900mmx450mmx750mm.Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate or as same as the Table,approved make & design & withappropriate balancer on the bottom or the topAllverticals supports panel should be of 1Smm 16.00 Each 12100.00 1g3500.oo prelaminated MDF Board. CPU uni Keyboard tray,with mouse restlo be provided.Appropriate EdgeBendlngs to be provided where necessary with PVC beading 2mm thck to be provided as per approved 169 Providing & Supplying depository/cashcabinet made up of CRCA steel with external size or 5g1 x 460 x 460 mm,2 nos of lockable drawers and single door cabinet fitted 3.00 Each 22848.00 68544.00with 6 leverlock system 1vith completein all respect. (approx weight 160 kg to 180 kg) as per approved 170 Book Case - 4 Door Book Case shall have the configuration or 914mm(W)x320mm(D)x1742mm(H). The unique design provides the right rigidity to the Top hinged doors ,which shall faci itate easy use.The Book Case shall be made fromprime quality steel. It shall have a Rigid Knock Down Conslructlon.The TopPannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA andother components from O.Smm CRCA. Each door shall have a 6 Lever Cam Lock with Comrron Key. 3mm thick glass should beused in each door for clear inside vision whih shall besecured Ina metalframe through a rubber gasket.11 Scissor Mechanism should be providedin each door for 20.00 Each 17248.00 344960.00receding Inside the top or every compartment andItshall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which Is easy to grip.Each compartment shall have a storage shelf with good capacity. The 4 Door Book Case shall have 18mm PLB Top straight edge with PVC lipping.The Hn shlngshall Include Epoxy powder coated.Complete work as per the as per approved colour,shape,design,type by engineer in charge. 171 150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 172 FIRE FIGTHING WORKProviding, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 173 100mm dia 174 80mm dia 175 50mm dia 176 40mm dia 177 32mm dia 178 25mm dia 179 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969and Bursting pressure 42 Kg/sqcm 180 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 181 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 182 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 184 Providing and fixing of Fire / Electrical Shaft Door made frompowder coated (50 Micron) aluminiumpartialy glazed with 6 mm thick glass and Partialy/ Fully Louvered with Outer frame of AluminiumSection of Size 100 mm x 45 mm x 1.5 mmand Shutters Top, Middle & sideSection of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mmComplete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR 450 LPM with 35 mtr head 186 Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Way 187 SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150mm dia 188 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 mm dia 189 100 mm dia 190 150 mm dia 191 200 mm dia 192 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 193 100 mm dia 194 80 mm dia 195 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg 196 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSRCapacity 4.5 Kg. 197 Supplying and Fixing ofGalvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Bucketsincludingassociated civil works etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 SITC ofResponse Indicatorfor indicating the activation of the Remotely located Detector for Conventional type detectors as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister typeHeat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Optical/Photoelectric type smoke detectorsof photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 1.5 sq.mm 204 3x 1.5 sq.mm 205 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4 Pair 206 2 Pair 207 Supplying and fixingof CE certified and UL listed GI wire mesh cable tray made from spot welded steel wirehot dipped galvanised between 60 and 80 microns of zinc as per BS 729including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods,etc. as required of following sizesAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .500 mm x 100 mm x 6 mm 208 300 mm x 100 mm x 6 mm 209 SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 SITC of PA system Operator Console of following wattage to be installed withConventionalfire alarm systemcomplete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1x 240 Watt 211 SITC 6 watt Speakermounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 213 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRLong point (up to 10 mtr.) 214 Long point(up to 10 mtr.) 215 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 216 Long point(up to 10 mtr..) 217 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR3x 1.5 sq.mm 218 3x 2.5 sq.mm 219 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 220 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 221 2 x 6.0 sq. mm. 222 4 x 10.0 sq.mm 223 4 x 16.0 sq.mm 224 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 225 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 226 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 227 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 228 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 229 Three pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 230 50/63 A rating 231 100 A rating 232 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 233 50/63 A rating 234 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTwo pole 30 mA sensitivity6A-32 A rating 235 40 A rating 236 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRGlazed door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 237 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box6Way(Incomer 8,Sub Incomer2+2+2) 238 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR6 Way(8+18) 239 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 240 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp.2 Moduleswitch With LedIndicator 241 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 Amp. 2 Module Socket 242 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRRJ-11 telephone jack Double line 243 RJ-45, Cat 6 computer jack with shutter 244 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1 Module 245 4 Module 246 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 247 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped) Strip 249 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 mm dia. 250 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 251 570mm (+/-10%) batten with min. lumen output 1000 lm 252 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3600 lm 253 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimumlumen output 650 lm 254 Minimum lumen output 1950 lm 255 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 257 Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specificationsGR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure A attached with this BSR50 pair 258 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm 259 Supplying and fixing of ISO Certified company made Krone module with base frameas per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .50 Pairs 260 CCTV SURVEILLANCE WORKSupply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 261 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6A, Sheilded Information Outlet 263 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Aperture 264 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 265 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 266 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 268 Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired. 269 SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement. 270 SITC of 42 inch full HD professional LED display for CCTV monitoring. 271 External Electrical WorkS I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 KVA 272 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 to 40 KVA 273 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 274 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 150.0 Sq.mm 275 MAIN LT PANELSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 276 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 277 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 278 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Shunt Trip Release 279 Under Voltage Release 280 Extended Rotary Handle 281 Auxiliary contact 282 Spreaders for 250A, 4 Pole MCCB 283 Spreaders upto 125A, 3 Pole MCCB 284 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 285 Providing & Fixing of ISO certified company made Four Pole By pass Change Over Switch conforming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 A 286 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 287 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 288 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 289 50/63 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
45.
Educational and Research Institute #10320058 Price Bid
Supply Of Tools And Equipment For Different Laboratories And Workshops Of Central Calcutta Polytechnic.- 1 Anbe Pic Programming Kit Pickit3 Compatible Pic Microcontroller Programmera Set Of Flash Programmers And Adapter Boards For Writing Programs On Microchips Pic Microcontrollers. Support Almost All Pics. This Is A Compatible Product Of Microchips Pickit3. It Can Be Used Without Problems With Mplab Ide Etc. Set Contents: Pickit3 Compatible Product, Usb Cable, 6-Pin Jumper Cable, Adapter Board, 400 Hole Bread Board, 2 Iduino Uno Project Super Starter Kit With And Uno R3 Compatible With Arduino Idekit Based On Arduino Platform To Starting Programming For Those Beginners Who Are Interested. Lcd1602 Module With Pin Header ( Not Need To Be Soldered By Yourself ) This Is The Upgraded Starter Kits With Power Supply Module, 9V Battery With Dc Uno R3. 100% Compatible With Arduino Uno R3, Mega 2560 R3, Nano. 3 My Technocare 8051 Development Board With Usb Isp Programmer Kit, Ds1307 Rtc Module Real Time Clock, 16X2 Lcd Display Yellow / Green, Onboard Zif Socket 40-Pin, Max232, Atmel At89s52 Microcontroller Ic 4 Plc Trainer Kit ( Siemens Plc ) With In Built Siemens Plc 14-Point Controller, Digital Inputs: 08 Nos, With 5Mm Banana Connector For Each Inputs. Digital Outputs: 06 Nos. With 5Mm Banana Connector For Each Outputs Software: Connected Components Workbench Software / Wpl Soft / Tia Portal., Supports Program Download Through Usb Programming Port Cabinet: 340 X 380 Mm Front Panel With Printed Circuit Board With Metal Cabinet. I / P-230V And Output-24V @3A. 3 Years Warrenty Against Manufacturing Defects 5 Elegoo 120Pcs Multicolored Dupont Wire 40Pin Male To Female, 40Pin Male To Male, 40Pin Female To Female Breadboard Jumper Wires Ribbon Cables Kit For Arduino 6 Analog Cro, 30 Mhz, Dual Trace 0-600V, Ac / Dc 7 Trainer Kit To Study Switching Characteristicsand Vi For Scr, Igbt, Scs , Triac And Diac, 0-100V Minimum, 0-5A Load Current 8 Scr Trainer , 0-100V, 0-5A 9 Scr Firing Trainer, R Firing Trainer, 10-90 Degree For 230V Supply, 50Hz 10 Ujt Trainer, Upto Khz, Amplitude 0-60V 11 Scr Commutation ( A, B, C ) Trainer , Compatible To 230V Ac, 50Hz 12 Scr Commutation ( D, E, F ) Trainer, Compatible To 230V Ac, 50Hz 13 Half Controlled Rectifier, 0-100V 14 Full Controlledrectifier, 0-100V 15 Ac Regulator Trainer, Compatible To 230V, Variable Output Upto 230V 16 Dc Series Motor Drive Using Scr, Drive Should Be For 3Hp Motor 17 Separately Excited Shuntmotor Drive Using Scr, Drive Should Be For3 Hp Motor Atleast. 18 Setup To Study Speed Control Of 3-Phase Induction Motor Using Pwm, Drive Should Be 35Hp Motor 19 Flat Plate Solar Collector, Collector Body-Sturdy, Pure Polyester, Powder Coated Frame, 2Sqm, 9 Nos. Copper Fins And Tubes. 20 Vi Charactertics Of Pv Cell Trainer Kit 21 Solar Water Heating System 22 Pyranometer, Sp [ Ecial Selectivity ( 350 To 1500 Nano Mete, Tilt Responce-0-90◦ At 1000W / Sq.M, Temp Response – ( -10 ) Degree, Field Of View 180◦ 23 Solar Cooker, Frp Body, 23”X23”X9”, Reflector Material-Mirror Glass 4Mm, 4 Nos Aluminium Container Covered With Toughened Glass 4Mm, Plain Glass 4Mm, Insulation Material – Glass Wool, Inbuilt Analog Temperature Meter. 24 Flat Plate Solar Collector 25 Power Factor Improvementby Static Capacitor, 12.5 Μf, 450V, 200 Mhenry / 1Amp, Resistance 500Ω / 400W, Auxiliary Power Supply 230V Ac, 50Hz, Mcb 2Amp 26 Pelton Wheel Water Turbine Cut View Model 27 Franciswater Turbine Cut View Model. 28 Kaplan Water Turbine Cut View Model 29 Dc Series Motor Drive Using Step Down Chopper, Compatible Upto 3Hp 30 Synchronous Motor And Panel For V Curve Plotting, 415V, 3Hp With Required Control Panel. 31 3 Phase Resistive Load Box Upto 15 A, 415 V 32 Time Period Of Oscillation Of A Cantilever-Metre Scale ( Wooden - 2 Nos. ) , G. Clamp ( Metallic ) -02 Nos, Slotted Weight ( 4 No. Each Of 50 Gm ) Brasssed Chromed-02 Set. Slotted Weight Holder With Hook ( Metallic ) -05 Nos. Stop Watch ( Dial 30 Sec, Max Time Time 30 Minutes, Least Count 0.1 Sec, Made Of Stainless Steel, Tested At Nabl Acreditated Lb 33 To Verify Kirchhoff’S Law Using Electrical Circuitsi ) Kirchoffs Law Trainer Kit With Meters ( Standard ) Ii ) I.C Regulated Power Supply, Output : 0-9 V, 0.2 Volt / Div @ 500 Ma Over Voltage And Over Current Protectioniii ) Variable Resistors ( 0 To 10K, 3 Values ) Plug Type Resistance Box ( Standard Quality Manganin Coils ) Iv ) Digital Multi-Meter:01 No. Dc Voltage: 0-200 Mv- 1000V , Dc Current: 0-20 Ma -10A, Ac Voltage: 0-20V- 700V, Ac Current: 0-20Ma-10A , Resistance : 0-200 Ohm -2 Mega-Ohm. Capacitance: 0-20 Nf- 200Μf, Frequency: 0-200 Khz, Make : Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab. 34 Galvanometer By Half Deflection Method.Tablei ) Table Galvanometer ( Moving Coil Weston Type ) - 3 Nos. ( Known Resistance And Figure Of Merit ) , Range : 30-0-30, Sensitivity : 2 Micro-Amp / Div ; Permanent Magnet Moving Coil Type. Bakelite Case. Size: 250Mm X 200Mm, Square Dial. Anti-Parallax Mirror Scale, Knife Edge Pointer, Make: Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab. Ii ) Battery Or A Battery Eliminator ( 0 - 6 V ) - 03 Nos.Iii ) Plug Type Resistance Box - 03 Nos. ( Standard Quality Manganin Coils ) , Range In Ohms :0 To 10K Ohmsiv ) Plug Type Resistance Box - 03 Nos. ( Standard Quality Manganin Coils ) - , Range In Ohms :0 To 200 Ohms., V ) Fractional Resistance Box, - 03 Nos. Range : 0 – 10 Ohm Vi ) One Way Keys ( Standard - 01 No. Pack Of 5 Nos. ) , Brass Block With Brass Terminals. Block Size: 56 X 10 X 10 Mm. Vii ) Digital Multi-Meter- 01 No.Specification Issame As Item No 33. ( Iv ) , V ) Connecting Wires ( Standard, 1 Coil Each ) - 35 Conversion Of Galvanometer Into An Ammeter Or A Voltmeter.I ) A Galvanometer, ( Known Resistance And Figure Of Merit ) , Specification Issame As Item No 3 ( I ) . ( Ii ) , A Battery Eliminator ( 0 – 3V, - 03 Nos.Iii ) One Way Key ( Standard ) - 01 Nos., Specification Issame As Item No 34. ( Iv ) Iv ) Wire Rheostat - 04 Nos. Range 0 – 200 Ohm, Length : 30 Cm, Dia 50 Mm ( Approx ) , Current : 2.5A , Make : Iso 9001-2008 Certified Co. And Tested, At Nabl Accreditated Lab. V ) Dc Milli-Ammeter - 03 Nos., Range 0-30 Ma , ( Div. 1Ma ) , Accuracy : + / - 1%, Permanent Magnet Moving Coil Type. Bakelite Case, Size: 250 Mm X 200 Mm. Anti-Parallax Mirror Scale, Knife Edge Pointer, Square Dial. Make : Iso 9001-2008 Certified Co. And Tested, At Nabl Accreditated Lab.Vi ) Dc Voltmeter - 03 Nos. Range 0 – 3 V, ( Div. 0.05 V ) , Accuracy : + / - 1%., Permanent Magnet Moving Coil Type. Bakelite Case. Size: 250 Mm X 200Mm. Square Dial. Anti-Parallax Mirror Scale, Knife Edge Pointer, Make : Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab.Vii ) Constantan Or Manganin Wire ( 26 Or 30 Swg, 10 Nos. ) , Viii ) Connecting Wires ( Standard ) . 36 Pn Jn Diode Characteristicsi ) Pn Jn Diode Characteristics Trainer Kit ( Compact ) , For Both Si And Ge Diode With, Ii ) 4Mm Bs-4 Jack Terminal For Various Test Point, Iii ) Power Led Indication, Iv ) Built Analogue Meter For Voltage And Current, Measurement - ( A ) Voltmeter : 0-3V, 0.05V / Div, ( B ) Voltmeter : 0-10V, 0.2V / Div, ( C ) Miliammeter : 0-15Ma, 0.3Ma / Div, Measurement. ( A ) Voltmeter : 0-3V, 0.05V / Div ( B ) Voltmeter : 0-10V, 0.2V / Div ( C ) Miliammeter : 0-15Ma, 0.3Ma / Div Micro Ammeter: 0-100 Μa, 1Μa / Div Variable Voltage Range By Potentiometer Arrangement : 0- 1.5V ( Forward Bias ) And 0 - 10V ( Reverse Bias ) Built In Regulated Dc Power Supply Ac Input : 230V Ac, 50Hz, +- 10%. Mounted On A Sophisticated Cabinet Accessories : Patch Cords. Make : Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab. 37 Po Box Experiment ( To Verify Series Law ) Post Office Box. ( Plug Type ) With .. Body Made Of Brass Inside Teak-Wood Made Case. Manganin Wire, Non Inductive Winding. Ratio Arms 10, 100, 1000 Ohm, Series Arms 1 To 5000 Ohm, 16 Coils. Two Tapping Keys ( 2 Mm Thickness ) For Galvanometerand Battery. Brass Made Plug Key ( Dia 7Mm, Length 20Mm Excluding Head ) And Brass Made Stud ( Thickness 12 Mm , Height 15 Mm ) . Connecting Terminals Should Have Heavy Threaded Knob. Wired Wound Resistor ( Fixed ) : Iso 9000 Certified Manufacturer. 5 Ohm, 1% Tolerance; - 10 Nos. 10 Ohm, 1% Tolerance;- 10 Nos. 20 Ohm., 1% Tolerance;- 10 Nos. Insulated Copper Wire For Electrical Connection, -2Roll Area 1.5 Square Mm. 38 To Verify Snell’S Law Of Refraction Of Light - 15 Set Rectangular Galss Slab , Crown Glass - 15 Nos Size : 4 Inch X 3.5 Inch X 1 Inch Drawing Board Made Of Soft Wood - 15 Nos Size : 18 Inch X 23 Inch, Good Quality. Stout Hair Pin.- 5 Box Board Pin - 5 Boxwooden Meter Scale ( 1 M ) - 2 Nos 39 Ohm’S Law Verification - 2 Set Ohms Law Apparatus Kitwith Built In ( Compact ) -2 Nos Dc Voltmeter, Range 0 – 3 V - 2 Nos Specification Issame As Item No 36. ( Iv ) Dc Milli-Ammeter - 3 Nos Range 0 To 500 Ma ( Div. 5 Ma ) , Accuracy : + / - 1% Permanent Magnet Moving Coil Type. Bakelite Case. Size: 250 Mm X 200Mm, Knife Edge Pointer, Anti-Parallax Mirror Scale, Square Dial. Make : Iso 9001-2008 Certified Co. And Tested At Nabl Accreditated Lab 40 To Verify Inverse Square Law Of Radiations Using A Photo Electric Cell. - 2 Set Photo Cell ( Selenium ) ( Mounted In The Metal Box With Connections Brought Out At Terminals ) Lamp Holder With Bulb ( 60W Bulb ) Moving Coil Analog Micro Ammeter Mounted On The Front Panel And Connections Brought Out At Terminals ( Range 0 - 500Μa ) . Moving Coil Analog Milli-Voltmeters Mounted On The Front Panel And Connections Brought+ Outat Terminals ( Range 0 -1000 Mv ) Wooden Bench Fitted With Scale ( Range ) Connecting Wires ( Standard, 1 Coil ) .- 1 Coil, 41 Capacitance And Permitivity Kit ( Digital ) ( To Determine The Permittivity Of Air At A Place ) - 2 Set 42 Focal Length And Magnifying Power:U-V Method. Optical Bench And Its Acessories ( Complete Set ) : 3 Sets Twin Bar 1.5 Meter Long Made Of Brass Chrome Plated Pipes Held In Strong Supports With Leveling Screws. One Pipe Is Graduated In Mm. Four Sliders With Four Sliders With Index Mark . Two Lens Holders And Two Pin Holders ( Made Of Brass ) Having Screw In Each Which Has Capability Of Vertical And Horizontal Displacement And With Two Pins Made Of Brass ( For The Determination Of Focal Length Of A Convex Lens By U-V Method ) . Spherical Double Convex Lenses With - 3 Nos Focal Length – 10 Cm, Diameter 60 Mm - 3 Nos Focal Length – 15 Cm, Diameter 60 Mm - 3 Nos Focal Length – 20 Cm, Diameter 60 Mm.- 3 Nos 43 Radius Of Curvature Of Concave / Convex Surface - 5 Nos Spherometer ( Complete Set ) With Linear Scale In Mm Circular Scale Divisions:100 Convex Mirror - 5 Nos Concave Mirror - 5 Nos Plane Glass Slab ( Big Size ) - 5 Nos Plane Mirror - 5 Nos 44 Spring Constant By Hooke’S Law Apparatus - 3 Set Retort Stand With Clamp, Spring With Hook At Both Ends, Weight Hanger With Hook ( 50 Gm ) Slotted Weight ( A Set Of Six ) 50 Gmeach A Vertical Wooden Scale A Fine Pointer 45 Co-Efficient Of Static Friction Between Wood And Glass. Horizontal Wooden Board With Glass Top, Fitted With Pulley At One End. Wooden Block ( With Slots On Top For Weight ) With Fixed Hook At One End. Weight Hanger With Hook. Slotted Weight ( 10 No. Each Of 20 Gm ) 46 Moment Of Inertia Of A Flywheel. Flywheel With Shaft. Weight Hanger. Stop Watch Meter Scale Slotted Weight ( Standard Set ) 47 Co-Efficient Of Linear Expansion Of A Metal Rod Pullinger’S Apparatus, With Scale And Thermometers. Optical Level High Resolving Power Telescope Meter Scale Thermometer A Metallic Rod 48 To Verify Boyles Law Boyles Law Apparatus : Complete Set With Accessories: Burette Graduated In Cc ( Or Ml ) With 1.0 Cc / Div. Scale Graduated On Both Sides ( Left & Right ) With Same Marking Fitted On A Teak Wood Made Frame ( Height 120 Cm, Width 10 Cm., Thickness 2.5 Cm ) With A Metrescall Attached At The Middle Of The Frame And Standing On A Cast Iron Made Base ( Length 22 Cm And Breadth 5 Cm ) Having Three Legs Two In Front And One At Back Side Each Having Length 8.5 Cm. ) . Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod ( 8 Mm Dia ) . High Quality Synthetic Tube ( 1.0 M Long ) Containing 750 Gm Hg. One Spare Synthetic Tube. ( With Extra 500 Gm Mercury ) . Fortin’S Barometer : ( Complete Set ) Brass Made, Supplied With Mercury Andcase Made Of Teak Wood. Open Plate Reflectors, Ringand Screws For Vertical Adjustments. A Dual Scale Graduated In 25 To 32 Inches And 64 Cm To 81Cm Is Read By Verniers Moving By Rack And Pinion, Reading To0.01 Inch And 0.1Mm Are Enclosed In A Glass Cylinder.A Glass Cistern At The Lower End Of Barometer Isprovided With An Ivory Point To Adjust The Level Of Mercury. Mounted On A Wooden ( Teak Wood ) Base. Covered With Glass Case. A Thermometer Is Provided On The Wooden Base. 49 To Find The Viscosity Of A Given Liquid ( Glycerin ) By Stokes Law With The Following Stake’S Law Apparatus For Viscosity Measurement : Neutral Glass Thick Tube About 1.25 Inch Diameter And 1 Meter Long Fitted On A Teak Wood Made Wooden Stand With A Meter Scale. The Glass Tube Is Having A Nozzle At The Bottom Fitted With A Rubber Tube And Pinch Cock. A Net Hanger And A Small Spherical Ball Of Three Different Dia ( 5 Each ) . Glycerine : 2 ( Two ) Litre Per Apparatus Castor Oil: 2 ( Two ) Litre Per Apparatus Screw Gauge Stop Watch Meter Scale 50 Relative Density Of Sand By Specific Gr. Bottle Hydrostatic Balance: Capacity 250G And Sensitivity 1 Mg, Body Made Of Teak, Wood, Made Of Brass With Others Accessories ( For The Determination Of Specific Gravity Expt. ) .Std. Weight Box:Chrome Plated Brass Weightsin Box, Containing From 1Mg To100g ( Grade “A” ) Isi Standard . Make: Iso 9001-2008 Certified Co. And Tested At Nabl Accredited Lab.- 4 Nos. Beaker, 150 Ml Capacity, Borosil. - 5 Nos. Beaker, 100 Ml Capacity, Borosil. - 5 Nos. Specific Gravity Bottle, 50 Ml Capacity. - 20 Nos. Wooden Bridge ( Teak Wood Made ) . - 5 Nos. 51 Computer -Key Highlightsprocessor- ( Intel 7Th Gen Or Amd Ryzen 3000 Series / Threadripper 2000 Series ) Or Higher Cpu Operating System- Microsoft Windows 10 ( 64-Bit ) , Version 1909 Or Laterram- 8 Gb Ddr4 Or Higher Storage- Recommended Ssd- 240 Gb Or Higher For C Drive And 1 Tb Hdd Or Higher For Storage 52 Laser Printer-Hp Laser 108A Single-Function Printer 53 Printer Cartridge-For Hp Laser 108A Single-Function Printer 54 Barcode Label Printer-Model Tvs Lp 46-Product Dimensions ‏ : ‎ 18.5 X 21 X 28 Cm; 4.52 Kilograms Manufacturer ‏ : ‎ Tvs Electronics Limited Asin ‏ : ‎ B08gsr5n6j Item Model Number ‏ : ‎ Lp 46 Neo Manufacturer ‏ : ‎ Tvs Electronics Limited Item Weight ‏ : ‎ 4 Kg 520 G Item Dimensions Lxwxh ‏ : ‎ 18.5 X 21 X 28 Centimeters Generic Name ‏ : ‎ Label Printer 55 Ribbon-Sun Retail 105Mmx300mts Thermal Transfer Barcode Labels Ribbon Super Wax For Printer ( Wax ) For Citizen Zebra Tvs Tcs Hbrt Godex Printer Paper Label ( Black ) 56 Paper Roll-Best Label Hub50x25 ( Thermal ) Barcode Labels Stickers, 4000 Label In Roll, 2Up 57 Bar Code Scanner-Tvs Electronics Bs-C101 Star Barcode Scanner | With A Top Trigger Button | 1D Linear Imager To Scanner | Speed Of 330 Scans Per Second | Enabled With Ultra Scan-Decoding 58 Anbe Pic Programming Kit Pickit3 Compatible Pic Microcontroller Programmer A Set Of Flash Programmers And Adapter Boards For Writing Programs On Microchips Pic Microcontrollers.Support Almost All Pics.This Is A Compatible Product Of Microchips Pickit3. It Can Be Used Without Problems With Mplab Ide Etc.Set Contents: Pickit3 Compatible Product, Usb Cable, 6-Pin Jumper Cable, Adapter Board, 400 Hole Bread Board, 59 Iduino Uno Project Super Starter Kit With And Uno R3 Compatible With Arduino Id Ekit Based On Arduino Platform To Starting Programming For Those Beginners Who Are Interested. Lcd1602 Module With Pin Header ( Not Need To Be Soldered By Yourself ) This Is The Upgraded Starter Kits With Power Supply Module, 9V Battery With Dc Uno R3. 100% Compatible With Arduino Uno R3, Mega 2560 R3, Nano. 60 My Technocare 8051 Development Board With Usb Isp Programmer Kit, Ds1307 Rtc Module Real Time Clock, 16X2 Lcd Display Yellow / Green, Onboard Zif Socket 40-Pin, Max232, Atmel At89s52 Microcontroller Ic 61 Plc Trainer Kit ( Siemens Plc ) With In Built Siemens Plc 14-Point Controller, Digital Inputs: 08 Nos, With 5Mm Banana Connector For Each Inputs. Digital Outputs: 06 Nos. With 5Mm Banana Connector For Each Outputs Software: Connected Components Workbench Software / Wpl Soft / Tia Portal., Supports Program Download Through Usb Programming Port Cabinet: 340 X 380 Mm Front Panel With Printed Circuit Board With Metal Cabinet. I / P-230V And Output-24V @3A. 3 Years Warranty Against Manufacturing Defects 62 Elegoo 120Pcs Multicolored Dupont Wire 40Pin Male To Female, 40Pin Male To Male, 40Pin Female To Female Breadboard Jumper Wires Ribbon Cables Kit For Arduino 63 Speaker Trainer To Study The Frequency Response And Directivity Characteristics. Built In Dc Power Supply, Audio Frequency Generator, Suitable Amplifier With Gain Adjustment, Sound Level Meter, 360 Degree Circular Scale With 2 Ft Diameter With Holding Structure, Clearly Printer Front Panel, Instruction Manual 64 To Study The Internal Layout Of B&W Tv Receiver And Measure Voltage Level To Sketch Composite Video Signal At Different Stages Of Tv Receiver:B&W Tv Receiver Trainer With Built In Facilities To Observe Composite Video Signal, Vertical And Horizontal Signal, Crt Based B&W Kit, Adjustment Must Be Provided For Sound, Vertical And Horizontal Amplifier In Front Of The Panel, Audio Video Signal Source, Clearly Printed Front Panel, Instruction Manual 65 Study Of Internal Layout Of Colourtv: Colourtv Trainer With Built In Facility To Observe Internal Layout. Different Test Points To Be Provided Ti Observe Different Waveforms, Audio, Video Signal Source, Clearly Printed Front Panel, Instruction Manual. 66 Fault Finding In Colourtv: Colourtv Trainer With Built In Facility To Observe Internal Layout. Different Test Points To Be Provided Ti Observe Different Waveforms, Different Fault Switch To Be Provided To Create Fault And Observe The Results, Audio, Video Signal Source, Clearly Printed Front Panel, Instruction Manual. 67 Test Various Sections Of Led Tv Receiver: Led Tv Trainer To Test Different Sections, Power Supply, Processor Card, , Led Screen, Audio Video Signal Source, Clearly Printed Front Panel, Instruction Manual 68 Dth Trainer With Tools For Installation 69 Demonstration Of Photocopier Trainer: Photocopiertrainer To Study Its Demonstration Working, Clearly Printed Front Panel, Instruction Manual 70 Demonstration Of Microwave : Microwavedemonstration Set Up To Study Its Working, Clearly Printed Front Panel, Instruction Manual 71 Demonstration Of Washing Machine: Washing Machine Demonstration Setup With Clearly Visible Transparent Cover, Clearly Printed Front Panel, Instruction Manual 72 Demonstration Of Refrigerator: Refrigeratortrainer With Facilities To Measure Different Parameters Like Voltage, Current, Power, Efficiency And Compressor Load, Clearly Printed Front Panel, Instruction Manual 73 Demonstration Of Digital Camera:Branded Digital Camera Demonstrator With Clearly Visible Parts. 74 Measurement Ofunknown Inductance By Maxwells Bridge:Maxwells Bridge Trainer For Measurement Of Unknown Inductance, 1 Khz 10V P-P Sine Wave Ac Source, Three Different Unknown Inductors, Suitable Bridge Balance Facility With Null Detector, Clearly Printed Front Panel, Instruction Manual 75 Lvdt Trainer Kit With Built In Power Supply, On Board Printed Diagram, Measuring Range Of Lvdt ( -10Mm To +10Mm ) , 1 Khz Ac Source, Digital Display For Voltage, Clearly Printed Front Panel, Instruction Manual. 76 Strain Gauge Trainer, Load Cell Strain Gauge Platform With Changeable Compression / Tension Mode, Suitable Instrumentation Amplifier, 500 Gm Weight Box, Calibrated Digital Display, Clearly Printed Front Panel, Instruction Manual. 77 Characteristics Of Rtd ( Pt100 ) : Trainer Kit To Measure The Temperature And Change Of Resistance Of Rtd, Temperature Controller With Digital Display, Clearly Printed Front Panel, Instruction Manual. 78 Characteristics Of Thermister: Trainer Kit To Measure The Temperature With Thermister, Temperature Controller With Digital Display, Clearly Printed Front Panel, Instruction Manual 79 Calibrate Single Phase Energy Meter With Phantom Load:Energy Meter Trainer Kit With Phantom Load Arrangement, Digital Voltmeter, Ammeter, Wattmeter, Single Phase Energy Meter, Clearly Printed Front Panel, Instruction Manual. 80 Calibrate Voltmeter With Cromptons Potentiometer: Calibration Set Up For Voltmeter, Volt Ratio Box, Standard Cell, Crompton Potentiometer, Mi / Mc Voltmeter, Clearly Printed Front Panel, Instruction Manual. 81 B-H Curve Experiment Training Kit 82 Hot Air Soldering Stationfor Smd Component Rework 83 Pid Controller Training 84 Bench Top Do Meter : Dissolved Oxygen Measurements In Ppm, Mg / L Or % Saturation.Accurate Readings In Varying Conditions With Temperature, Salinity And Barometric Pressure Compensation. Large Easy To Read Display. Ready Indicator Lets You Know When Readings Are Stable. Non-Volatile Memory Holds Up To 100 Data Points. Integral Electrode Holder Dissolved Oxygen Range0 To 30Mg / L % Saturation Of Oxygen Resolution 0.1% / 1%Resolution 0.01 Mg / L Accuracy ±0.5% Full Scale Salinity Correction Range 0 To 50 Ppt Temperature Resolution 0.1 Range Accuracy ±0.50C / ±0.90F 0 To 1000C / 32 To 2120F Resolution 0.1 Barometric Pressure Correction Power Range 450 To 825 Mm Hg 110 / 240 V Ac Smps 9V Dc Adapter 1.3 A. Range 450 To 825 Mm Hg110 / 240 Ac Smps 9V Dc Adapter 1.3 A Resolution 1 Accuracy Manual Input Method Galvanic 85 Conductivity Meter / Tds: For Routine Applications In Laboratories, Production Plants And Schools. Must Be Reliable, Accurate And Consistent Performance. Large Screen That Displays Conductivity Or Tds Readings With Temperature In 0C And 0F. Ready Indicator To Know When Readings Are Stable. Selectable Cell Constant Auto-Ranging Across 5 Conductivity And Tds Ranges Up To 5 Point Push Button Calibration Non-Volatile Memory Hold Up To 100 Data Points Integral Electrode Holder, Automatic Temperature Control Probe. Conductivity Range .1Μs / Cm To 200.0Ms / Cm Resolution 0.01Μs; .01Μs; 1Μs; 0.01Ms; 0.1Ms Accuracy ±1% Full Scale Cal. Points Automatic ( 4 Points ) Maximum 1 Per Range; Manual ( 5 Points ) ; Maximum 1 Per Range Cell Constant .01, 1.0 10.0 ( Selectable ) Tds Range 0.1 To 100 Ppt @ 0.5 Tds Factor ( To 200Ppt @ 1.0 Tds Factor ) Resolution 0, 01Ppm; 0.1Ppm; 1Ppm; 0.01Ppt; 0.1Ppt Power 110 / 240 V Ac Smps, 9V Dc Adapter, 1.3 A Output Rs-232 86 Electro Pneumatic Trainer Kitthe Pneumatic Kit Shall Be Of Sleek Design And Portable One With Wheels. This Unit Is To Be Provided With Standard Aluminium Based Mounting Board ( Modular Type ) With All Trainer Kits So As To Make The Pick & Place Of Components Easier. All The Products Are To Be Provided With Suitable “One Touch Fittings / Push-In Fittings”. All The Components Used Shall Be Of Reputed Make Like Festo / Janatics / Rexroth Or Any Other Reputed Make Acceptable To Polytechnic. Vendor Has To Specify The Make With Catalogue.The Following Experiments Should Be Possible To Carry Out Using The Kit:A ) To Learn About The Fundamentals Of Pneumatics With Components ( Frl Unit, Compressor, Dc Valves, Pressure Control Valves, Pneumatic Cylinders, Accessories, Etc ) – Functions, Symbols, Working Principle & Applications. B ) To Build Up A Pneumatic Circuit With Applications Like Lifting & Holding A Load, Clamping / De-Clamping, Speed & Load Control In Double Acting Cylinder, Speed Control Of Pneumatic Motor Etc. Vendor Has To Provide The Learning Resources – Basics Of Pneumatics, Different Pneumatic Circuits ( Minimum 7 Experiments ) And Components For It. Vendor To Provide The List Of Experiments With Components Required Along With Offer. Scope Of Supply: Vendor To Supply The Following Items ( Minimum ) :1. Air Compressors- Displacement 3Cfm, Working Pressure – 7Kg / Cm2 ( 7 Bar ) With 0.5Hp 650 Rpm Electric Motor 230V, 50Hz, 1 Phase With 0-10 Bar Pressure Gauge & Shut Off Valve With Suitable Hose And End Connector. 2. Filter Regulator And Lubricator ( Frl ) Unit With Pressure Gauge ( 10Bar ) – 1 No. 3. Direction Control Valves Of Different Configuration ( 5 / 2 Way Lever Operated -4 No., 5 / 2 Way Single Solenoid Operated - 2 No., 5 / 2 Way Double Solenoid Operated -2 No, & 5 / 3 Way Lever Operated - 3 No, 3 / 2 Way Roller Operated Valve – 1 No ) . The Size Of The Valves Shall Be Of ¼” Bsp. 4. Set Of Pressure Control Valves, One Way Valves, Flow Control Valves, Shut Off Valves, Or Gate & And Gate Shuttle Valves, Time Delay Valve, Quick Exhaust Valve ( Minimum – 1 No Each ) Or Of Sufficient Quantity To Execute The Experiments. The Size Of The Valves Shall Be Of ¼” Bsp. The Vendor To List Down The Type, Specification And Quantity Of Valves Offered. 5. Single Acting Cylinder - Bore 25Mm, Stroke 100Mm With Suitable Mounting Arrangement –1No. 6. Double Acting Cylinder - Bore 25Mm, Stroke 100Mm With Suitable Mounting Arrangement - 2 Nos. 7. Pneumatic Motor - 1 No, 8. Required Length And Quantity Of Pneumatic Hoses With Suitable End Fittings Of Quick Snap Type And Ell, Straight & Tee Fittings Of Required Quantity Have To Be Provided. 50% Extra Spares Of This Hoses And Fittings To Be Supplied. Details Of Supply Are To Be Specified In The Offer. 9. Hand Tools Required For Carrying Out The Experiment – 2 Sets To Be Supplied.10. Required Electrical Controls With Sockets For Solenoids, Etc. Proposed For Supply To Be Specified And Listed In The Offer. 11. Any Other Items Required To Carry Out The Basic Experiments And Proposed For Supply To Be Specified And Listed In The Offer. 11. Any Other Optional Items Required To Improve The Performance Or To Carry Out Additional Experiments And Proposed For Supply Shall Be Specified And Quoted As Optional, Which Will Be Selected Based On Our Requirement. 87 Electro Hydraulic Trainer Kitspecification: 1. The Hydraulic Kit Shall Be Of Sleek Design And Portable One With Wheels. 2. Provided With Standard Steel / Aluminium Based Mounting Board ( Modular Type ) With All Trainer Kits So As To Make The Mounting Of Components Easier. 3. All The Products To Be Provided With Suitable Quick Disconnect Couplings. 4. All The Components Used Shall Be Of Reputed Make Like Rexroth / Vickers Or Any Other Reputed Make Acceptable To Polytechnic. Vendor To Specify The Make With Catalogue. 5. The Following Experiments Should Be Possible To Carry Out Using The Kit: A ) To Learn About The Fundamentals Of Hydraulics With Components ( Dc Valves, Pressure Control Valves, Flow Control Valves, Hydraulic Cylinders, Accessories, Etc., ) B ) To Build Up A Hydraulic Circuit With Applications Like Hydraulic Press Circuit, Clamping / De-Clamping, Meter-In / Meter-Out, Speed Control & Load Control In Double Acting Cylinder, Sequencing Circuit, Counter Balance Circuit, Etc. 6. Vendor To Provide The Learning Resources – Basics Of Hydraulics, Different Hydraulic Circuits ( Minimum 7 Experiments ) And Components For It. Vendor To Provide The List Of Experiments With Components Required Along With Offer. 7. Operation & Maintenance Manual To Be Supplied - 2 Hard Copies And 1 Soft Copy With The Equipments. Scope Of Supply: Vendor To Supply The Following Items ( Minimum ) : 1 ) Trolley With Frame, No. Of Wheels - 4, Two Fixed & Two Swivel Type. Load Mounting Capacity: 500 Kg 2 ) Hydraulic Power Pack With Following Capacity: Operating Pressure: Around 40 Bar. Flow Rate: Around 5 Lpm. The Power Pack Includes The Following Components: A ) Hydraulic Tank Capacity Around 50 Litres. B ) Suitable Pump & Electric Motor ( Single Phase – 230V, 50 Hz, 1440 Rpm Induction Motor ) Coupled With Bell Housing And Mounted Externally Over The Tank With Vibro-Mounts. C ) Safety Relief Valve With Variable Pressure Setting. D ) Accessories Like Drain Plug, Suction Strainer, Return Line Filter, Electrical Power Source For Solenoid Valves, Valve Mounting Sub-Plates, Hydraulic Fittings, Etc. E ) Required Quantity ( Min. 8 Nos. ) Of Hydraulic Hoses Of Suitable Length With End Fittings And Quick Couplings, Transparent Hoses On Return Lines And Leakage Lines. 3 ) All Types Of Valves To Carry Out The Experiments Proposed. The Valves Include: A ) Solenoid Operated Dc Valves – 4 / 2 Way – 2 No And 4 / 3 Way – 2 No Types ( Solenoid Voltage: 24V Dc ) B ) Manual Operated Dc Valves 4 / 2 Way – 2 No And 4 / 3 Way – 2 No Types. C ) Pilot Operated Dc Valve4 / 2 Way – 1 No And 4 / 3 Way – 1 No D ) Pressure Relief Valve – 1 No E ) Pressure Reducing Valve – 1 No F ) Pressure Sequence Valve – 1No G ) Flow Control Valve – 1 No H ) Non-Return Valve- 1 No 4 ) Hydraulic Cylinders – A ) Single Acting Cylinder – Spring Return Type ( Size: Bore Dia. Around 20Mm X Rod Dia. 12Mm X Stroke 200Mm ) B ) Double Acting Cylinder ( Size: Bore Dia. Around 20Mm X Rod Dia. 12Mm X Stroke 200Mm ) Seals: Bushak&Shamban / Merkel / Freudenberg Or Any Other Reputed Make Acceptable To Polytechnic. Max Operating Pressure: 100 Bar, Normal Operating Pressure: 40 Bar Piston Rod: Chrome Plated And Hardened. 5 ) Hydraulic Motor: Type: Gear Motor / Piston Motor Direction Of Rotation: Bi-Directional Normal Operating Pressure: 40 Bar, Max. Pressure: 100 Bar, 6 ) Flow Meter – 1 No Type: Acrylic Hone Type Flow Meter With Scale, Rotameter, Working Pressure: Around 40 Bar 7 ) Proximity Sensor: 2 No Type: Contact Less Proximity Sensor Pnp Type, Operating Voltage: 24 V Dc, 8 ) Equipment Trays: 4 No, The Tray Design Is Such That The Supplied Components Can Be Kept In The Tray. Also The Trays Have Space For Each Individual Component. 9 ) Pressure Gauges – 5 No ( Glycerine Filled ) Of Suitable Range To Measure The Pressure At Various Points ( Pressure Line, Return Line, Reduced Pressure Line, Suction Line, Etc. ) 10 ) Hand Tools Required For Carrying Out The Experiment – 2 Sets To Be Supplied. 11 ) Any Other Items Required To Carry Out The Basic Experiments And Proposed For Supply To Be Specified And Listed In The Offer. 12 ) Any Other Optional Items Required To Improve The Performance Or To Carry Out Additional Experiments And Proposed For Supply Shall Be Specified And Quoted As Optional, Which Will Be Selected Based On Our Requirement. 88 Separating & Throttling Steam Calorimeter With Boiler Specification-This Set Up Mounted On A Bench Fully Instrumented To Determine Quality Of Steam At Pressure Of Steam 8.0-10.0 Kg / Cm2 Using Separating Throttling Calorimeter With Steam Condensing Plant, Non Ibr Small Steam Boiler Shell Fitted With Immersion Heater And Furnish With Safety Valve, Pressure Gauge, Digital Thermometer, Steel Lagging Jacket, Power Supply For Heating: 230 V, Single Phase Ac. Arrangement For Drainage Of Waste Water After Experiment. Operation & Maintenance Manual. 89 Spanner Set8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19 Mm Combination Spanners 90 Spanner Set 1 / 8 X 3 / 16, 3 / 16 X 1 / 4, 1 / 4 X 5 / 16, 5 / 16 X 3 / 8, 3 / 8 X 7 / 16, 7 / 16 X 1 / 2, 1 / 2 X 9 / 16, 9 / 16 X 5 / 8, 5 / 8 X 3 / 4 91 Supply And Installation Of Izod And Charpy Testing Machine With Specimen For Testing 92 Supply And Installation Of Torsion Testing Machine. Capacity 200 Nm, Power Supply- 260Vac At 50 Hz, 12 Months Warranty From The Date Of Installation, Least Count 0.1 Degree ( Deflection ) , Measuring Units- Nm, Ncm, Kgcm ( Selectable ) , Maximum Deflection- 180Degree, Accuracy + 1% Of The Reading 93 Electrode Holder Full Brass Body Inside 5Mm Electrode Size Dimensions ( Lxwxh ) -23.6X3.5X8.9 Mm Insulated Handle Made Of Fiber Glass Polyamide And Head From Dmc 94 Lathe Machine Hmt Lathe Machine, Nh22 Height Of Centers:220 Mm Swing Over Bed:500 Mm Swing Over Cross Slide: 270 Mm Swing In Gap ( Optional ) : 720 Mm Distance Between Centers: 1000 Mm Spindle Nose / Bore- A2-6* / 53 Mm Spindle Speed Range: 16 From 40 Rpm-2040 Rpm Forward And 7 From 60 Rpm-1430 Rpm Reverse Spindle Power= 11 Kw, Feed Range ( Longitudinal ) : 60 From 0.04- 2.24 Mm / Rev, Feed Range ( Cross ) : 60 From 0.02-1.12 Mm / Rev Lead Screw Pitch- 6 [ Or 4Tpi Acme ] Mm, Metric Threads: 48 From 0.5-28 Mm, Main Motor Power=7.5 ( Std. ) / 11.0 ( Opt. ) Kw, Tailstock Sleeve Travel= 200 Mm 95 Brinell Microscope Lamp 96 Coefficient Of Friction Tester Coefficient Of Static Frictio Tester ( Analogue ) 97 Experimental Setup For Determining Modulus Of Rigidity , Strain Energy, Shear Stress And Stiffness By Load Deflection Method ( Closed Coil Helical Spring ) Setup, Installation And Demonstration 98 Supply And Installation Of Morse Test Experimental Setupnumber Of Cylinder - 4 Cylinder 99 Model Of Impulse Steam Turbine Axial Flow Impulse Turbine 100 Layout Of Hydroelectric Power Plant Including Dam, Reservoir, Penstock, Nozzle, Hydraulic Turbine, Surge Tank Etc. ( All Models ) 101 Sprit Level 102 Bevel Protractor With Tapered Specimen For Angle Measurement 103 Gear Tooth Vernier Calliper Graduation-0.02 Mm, Accuracy -0.04 Mm 104 Tachometer Testing Range- 2.5 To 99999 Rpm, Resolution- 0.1 Rpm ( 2.5 To 999.9 Rpm ) And 1 Rpm ( Over 1000 Rpm ) , Accuracy- +0.05%, Detecting Distance: 2 To 20 Inch 105 Screw Pitch Gauge Range 0.25- 6.00 Mm Thread 106 Radius And Fillet Gauge Range 1 Mm To 7Mm 107 Plug Gauge And Ring Gauge Supply Of Plug Gauge ( 1 Unit ) And Ring Gauge ( 1 Unit ) 108 Sheet Metal Gauge Minimum Range 1 Mm To 30 Mm 109 Cut Section Model Of Shell & Tube Type Heat Exchanger 110 Cut Section Model Plate Type Heat Exchanger 111 Experimental Setup For Determination Of The Thermal Conductivity Of A Solid Metallic Rod 112 Cut-Section Model Of Check Valve 113 Cut-Section Model Of Needle Valve 114 Tig Welding Machine With Gas Cylinder 115 Projector : Projection System: 3Lcd Technology, Rgb Liquid Crystal Shutter Lcd Panel: 0.55 Inch With C2 Fin Colour Light Output: 3, 600 Lumen-2, 400 Lumen ( Economy ) White Light Output: 3, 600Lumen Resolution: Xga, 1024 X 768, 4:3 Native Contrast: 16, 000 : 1 Lamp: Uhe, 210 W, 6, 000 H Durability, 12, 000 H Durability ( Economy Mode ) Keystone Correction: Auto Vertical: + / - 300 , Manual Horizontal: + / - 300 Colour Reproduction: Upto 1.07 Billion Colour Throw Ratio: 1.48-1.77:1 Zoom: Manual, Factor: 1.2 Screen Size: 30Inches - 300 Inches Projection Lens F Number: 1.49 - 1.72 Projection Lens Focal Length: 16.9 Mm - 20.28 Mm Image: Optical: Specification For Laser Printer: Specification For Projector: Technology: Offset: 8:1 Usb Display Function: 3 In 1: Image / Mouse / Sound Interfaces: Usb 2.0 Type B, Rs-232C, Ethernet Interface ( 100 Base-Tx / 10 Base-T ) , Wireless Lan A / N, 5Ghz ( Optional ) , Vga In ( 2X ) , Vga Out, Hdmi In, Composite In, Stereo Mini Jack Audio Out, Stereo Mini Jack Audio In ( 2X ) , Cinch Audio In, Usb 2.0 Type A Other Feature: Av Mute Slide, Automatic Keystone Correction, Built-In Speaker, Digital Zoom, Direct Power, On / Off, Document Camera Compatible, Easy Osd Presetting, Horizontal And Vertical Keystone Correction, Network Projection, Osd Copy Function, Pc Free, Quick Corner, Split-Screen- Function, Iprojection App, Iprojection Set-Up By Nfc, Iprojection Set-Up Qr Code Warranty: 3 Years On Projector, Lamp: 1 Year Or 1, 000 Hours Whichever Is Earlier
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 16
West Bengal View Result →
46.
Housing Urban and Rular Development #10282555 Price Bid
Operational And Maintenance Of The Swimming Pool And Other Miscellaneous Works At Ludlow Castle Wrestling Venue, Training Centre, Delhi-54- 1 Initial Filling of water in the Swimming pool of approximate 5,00,000 litre capacity after cleaning the pool by help of various acids through back-washing method including servicing of pumps, starter and other equipment’s etc. filling of pool with water, initial dosing of chemical and submission of 1st water test report approved from NABL to the Engineer-in-charge etc. complete as reqd. 2 Cleaning ,Running, Operation of Sand filter including check & refilled Sand for required mark and change the faulty ball valves or top mount plate etc complete as reqd. 3 Repair & Replacement of all types ofMS / GI / PVC/ CPVC / UPVC Pipes & Ball Valve / Gate Valve / NRV / Butterfly valve etc. with their accessories of Swimming pool Campus etc. complete as and when reqd. 4 Running, operation and upkeeping of swimming pool and plant including cleaning of deck area, bath room, drain channel and operation of suction sweeper to clean sedimentation settled at the bottom of the pool to keep the pool clean including replacement of nylone rope, nylone brushes etc. as and when required i/c maintenance and operation of 2 Nos. 10 HP filter pump and 2 Nos. 5 HP submersible pump for makeup of water complete etc as reqd as and when required, attending day to day complaints of electrical installations and compound lights including repairing the wiring and light fixtures complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc. on account of failure of above services for their proper functioning alongwith repair works, as and when required and recording reading in log book, keeping the entire installation on functional mode on all days of the month i/c Sunday and holidays by deploying following staff, maintaining the record i.e attendance Register, complaint register duly signed by the client and site Engineer as per direction of engineer-in-charge and as per terms and conditions attached.a) Operator- 3 Nosb) Khallasi - 2 Nos. c) Electrician - 1 No 5 Supplying and dosing of day to day chemicals for swimming pool consisting to maintain the water quality as per with the standards of swimming pool, including daily water testing by testing kits including keeping records (duly signed by the clinet and site Engineer) of PH Value and Chlorine Level of Pool-water as required at site with the following chemicals for the swimming pool. (For approximate 12 Lacs litres water capacity swimming pool) 6 HCL 7 Alum 8 Soda ash 9 CuS04 10 TCCA90 11 Monthly basis testing of swimming pool water from the reputed and Govt. recognized test laboratory i/c collection of water sample from pool, sending the sample to the lab and collection of report and submitting the test report to the site Engineer etc. complete as reqd. 12 Comprehensive Annual Maintenance contract and service charges for 55kw heat pump which includes supply and replacement of components found defective, servicing, repairing, rectification of condenser coil, cooling coil, thermostat relay, PCB, fan motor, electrical wiring, gas charging if found necessary including replacement / repairing of sealed compressors etc. complete as required. 13 Comprehensive Annual Maintenance contract and service charges for 1.5/2.0/4.0 TR Split type AC (invertor/non-invertor) units which includes supply and replacement of components found defective, servicing, repairing, rectification of condenser coil, cooling coil, thermostat relay, PCB, fan motor, electrical wiring, gas charging if found necessary including replacement / repairing of sealed compressors etc. complete as required. 14 Supply of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with remote for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 15 Supplying, Installation, Testing and Commissioning of 450 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd. 16 Supplying, installation, Testing & Commissioning of SWIMMING LED light (Round / Polycarbonate body / SS304) Operating temp range -15 deg to +40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating . complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required , . Shape size and CCT shall be as approved by Engineer in charge. System lumen efficacy ≥105 and <120 lm/Watt output All as per pre approved by Engineer-in-charge. a) 54 watt 17 Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 18 12 -15 watt 19 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 20 18- 22 watt 21 Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 22 150 watt 23 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V C curve DP MCB complete with connections, testing and commissioning etc. as required. 24 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 25 mm 26 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as re uired. 27 3 x 1.5 sq.mm 28 3 x 4 sq.mm 29 3 x 6 sq.mm 30 Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 31 100 Amp , 16 KA, TPMCCB 32 125 Amp , 16 KA, TPMCCB 33 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 34 Single Pole 35 Double Pole 36 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 37 3 Module 38 6 Module 39 8 Module 40 12 Module 41 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 42 5/6 A switch 43 15/16 A switch 44 3 pin 5/6 amp socket outlet 45 6 pin 15/16 A socket outlet 46 Supplying and laying of following size XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 7098 (Part I) ISI on wall surface as required. (Clamped with 1 mm thick saddle/25x 3 mm MS flat clamp) 47 3 x 10 Sqmm 48 Lowering and Lifting of 5 to 10 HP three phase submersible -open well mono block pump set in existing under ground water tank with the help of chain pulley block and tripod stand along with GI pipe complete as reqd. 49 Rewinding, repair and servicing of following monoblock/ mono submersible pump set/ submersible pump set suitable for run 3 phase, 440volt, 50 Hz AC supply i/c dismental from existing locationand carriage (to and fro) to the workshop and testing, commissioning with credit of scrap copper wire and other parts etc.as required. 50 5 to 10 HP 51 S.I.T.C of 440 volt 50Hz, 3 Phase, semi autimatic star-delta stater panel suitable for 5/7.5/10 HP Open-well / borewell motor pump set having Ammeter, Voltmeter, Selector Switch, Single phase priventer etc as reqd.with credit of old dismentled material as reqd. 52 Supplying, Installation, testing of commissioning of 7.5 HP 440 Volt, 2900 RPM 8 stage Borewell submersible pump set capable of delivery of390 LPM at the head of 22meter directly coupled with submersible electric motor size 50 mm dia i/c GI pipe nipple, 50 mm flange, cable G.I pipe loweringmaking connection as reqd.i/c removing old pumpset trsting complete in all respect as reqd. 53 Supply, installation, testing and commissioning of Reverse Osmosis System with capacity of 250 LPH designed for Treatment of saline water in the TDS range of 500-2000ppm which are Completely assembled /Pre-piped/Pre-wired with Microprocessor-based control Pannel for ease of operation and inbuilt process Logic having provision for Auto start/stop based on Water level in the Tank with MCB for Plant operation and Raw water pump integrated with Plant. Integrated pretreatment Module for removal of suspended solids along with pressure gauges, Robust high Pressure Pump in SS 304 Construction, Inbuilt Protection to high Pressure Pump by Way of Low Pressure Switch/high Pressure switch and Glycerine filled SS Pressure gauges for durability, On line Rota meter for measuring permeate flow and Powder coated MS skid with plated hardware. RO plant have Pressure Sand Filter of 1000 LPH, Activated carbon Filter of 1000 LPH, Antiscalant Dosing System with tank capacity of 50 Litre, Micron cartridge filter of 5 micron, 10 long, High pressure pump of 1000 LPH , 1.2 KW, RO membrane of 4*40 - 1 Nos. of GE/Equivalent having backwash facility along with 1 Year Maintenance wrt Replacement of Micron Cartridge Filter and Antiscalant Chemical. The Company is having their NABL Accredited Lab Testing facilities in Delhi. Our Product Is ISO 9001 , Indian Medical Association Certified GC (Green Company) Mark BIS certificate,ISO 14001, ISO17025, ISO9001i/c credit for existing RO plant etc. as required. 54 Supplying, Installation, Testing & Commissioning of self contained storage type water cooler suitable for operation on 230 V single phase A.C. supply having following capacity per hour cooling capacity & storage capacity with SS304 stainless steel body, air circulation R-32/R-410 /R-407/ R134a Green Refrigerant with Scroll / rotary compressor with min 5 year OEM warranty of compressor, water over flow 1/2 BSP (connections) i/c MS Angle Iron Stand of suitable size, complete and other accessories i/c connection testing etc as reqd. 55 storage 150 ltr, cooling capacity 150 ltr per hr 56 Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminum Body including trim 57 12 -15 watt
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
47.
Drinking Water Supply and Sanitation #10279059 Price Bid
Tender For Rehabilitation Improvement And Basic Facility Of Parbati Dam District Dholpur. - 5.1.2Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard / dense soil 2 Dismantling doors, windows and clear story windows (steel or wood) shutters including chowhats, architrave and holdfastsetc. Complete and stacking 50 m lead of area 3 square meter and below 3 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 5 to 10 m depth 4 Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 50 x 50mm x 16 gauge 5 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . WITH 225 mm sweep 7 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011. withStainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure A attached with this BSR . 0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPM 8 Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1.5 TR ISEER not less then 3.8 9 Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for Superstructureincluding curing all leads of all construction materials including curing etc. complete. in cement sand mortar 1:4 10 Add extra over item No. 18 (b) for compaction in restricted area nearby structure or flanks by hand rammers or by pneumatic tampers. 11 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 10 to 15 m depth 12 Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density.)By Mechanical Means: Grading- I (Using Screening Crushable type such as Moorum or Gravel)Using Screening Crushable type such as Moorum or Gravel 13 11.5.4Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 15 to 20 m depth 14 Prime coat (Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60kg/sqm using mechanical means 15 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. From 20 to 25 m depth 16 Tack coat Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom 17 Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required. Beyond 25 m depth 18 Open - Graded Premix Surfacing (Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8- 10 tonne capacity, finished to required level and grades.)(I)a Case - I: Mechanical method using Penetration grade Bitumen and HMP of appropriate capacity not less than 75 tonnes/hour .Using VG-30 binder 19 Drilling more than 48 mm but upto 76 mm dia, holes in all types of rock or artificial hard material like concrete or masonry for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.Up to 5 m. depth 20 Providing and laying premix seal coat using hot mix plant and paver finisher with aggregates of 6.7mm size defined as 100% passing through 11.20mm sieve and retained on 2.36mm sieve with 0.09 cum per 10 Sqm and 4.5%bitumen including preparation and transportation of mix, spreading, laying and rolling etc. complete in all respect including cost of binder.(ii) Bitumen grade VG30 @ 4.50% 21 Drilling more than 48 mm but upto 76 mm dia, holes in all types of rock or artificial hard material like concrete or masonry for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.From 5 to 10 m depth 22 dismantling roofs with care including stacking of serviceable material and disposal of unservicable material within 50m lead for lime terrace 23 Supplying and lowering into holes and fixing of casing pipes of suitable diameter to enable drilling of minimum 48 mm dia grout holes. 24 dismantling stone slab roofing over wooden karries or RCC battens ( dismantling karries and battens to be paid for separately) including stacking of servicable material and disposal of unservicable material within 50 m lead 25 11.7Washing and open flushing of drilled holes by alternate jet of air and water under pressure prior to pressure washing and flushing or grout after stage grouting including cost ofequipment, compressed air and etc. complete. 26 Dismanling old plaster or skirting , raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 m lead 27 11.8Normal pressure washing of drilled hole in stages in approved pattern for cleaning of clay, soil and other filler materials from the seams and joints in the foundation rock by establishing connections under pressure with air & water including cost of equipment, accessories compressed air, water, labour, admixtures if any required etc. complete as per specification. 28 Dismantling flooring with care including stacking of servicable material and disposal of unservicable material within 50 m lead for: cement concrete flooring 29 5.16.1Earth work in rough (borrow area) excavation for embankments in hard soil, morrum or highly weathered strata dry or moist, including laying in 20 cm layers (before compaction) and breaking of clods, sorting of grass, pebbles etc. and dressing when compacted by vibro compactor, vibro sheep foot roller, sheep foot roller/pneumatic tyred roller to obtain dry density of at least 98% of Standard Proctor s density with initial lift of 1.5m (Excluding charges for compaction and watering) including loading and un-loading wherever required complete in all respect.With initial lead of 250 m 30 Supply and fixing of steel doors, with frame of hollow metal pressed section 105×60 mm as per I.S.I 1.25mm thick with double sheet shutter 1.00 mm thick M.S. sheet tospot welded and embossed with rib type design on both sides, front side vertical and back side horizontal and spot welded including hold fasts of (15×3mm), M.S. oxidized fittings such as butt hinges sliding door bolts, handles, tower bolts etc. complete in all respect as per drawing and specifications including applying priming coat of approvedsteel primer 31 11.10Conducting water intake test in test holes under pressure for determining permeability before or after grouting including cost of equipment and water etc. complete 32 Earth work in excavation in foundation trenches or drains including dressing of sides & ramming of bottoms , lift up to 1.5 m including taking out the excavated soil & depositing & refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within lead of 50 m : all kind of soils 33 11.9Grouting of drilled holes minimum 35 mm dia with or without packers with cement/ clay and or chemicals (in the form of slurry with water) in prescribed ratio till refusal including cost of grouting equipment, compressed air and water etc. complete but excluding cost of cement, clay and chemicals (only dry weight of ingredients excluding chemicals to be considered ) with a working pressure upto 15 kg/Cm2 (Dry cement consumption) 34 Providing and laying in position cement concrete including curing, compaction etc.complete in specified grade excluding the cost of centering and shuttering - all work up to plinth level: M10 grade nominal mix (with graded stone aggregate 20mm nominal size (P.C.C. in foundation) 35 16.33Exploratory vertical drilling of bore holes 150 mm dia through all kind of soils with the adequate / suitable equipments, tools and tackles for depths mesured below existing ground level including mobilization, setting up boring rig, shifting of rig from 1 bore hole to another and demobilization of the same 36 Random Rubble Stone masonry for superstructure above plinth level one storey height above 30 cm thick walls in: cement sand mortar 1:6 37 16.32.3Boring NX dia (54.7 mm dia), hole with diamond coring bits including taking out of core and arranging etc. core in proper order in core boxes including cost of core boxes. as per relevant I.S. code of practice. These rates are including Mobilization & demobilization of Rig. In sand stone and harder variety of lime stone 38 Filling available excavated earth ( excluding rock) in trenches ,plinth side of foundation etc. in layer not exceeding 20 cm. in depth , consolidating each deposited layer by ramming amd watering including lead up to 50 m and with all lift 39 5.1.3Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard soil mixed with Kankar / boulders, Morrum 40 Brick masonry in foundation and plinth with bricks of class designation 75 in: cement mortar (1:6) (1 cement : 6 coarse sand) , add extra for superstructure upto third storey 41 10.1.1Side shuttering including propping etc. complete (to achieve finish F 2 for :Block joints of foundation stilling basins buckets, aprons etc. (non -suspended horizontally laid massconcrete) 42 Providing and laying in position specified grade of cement concrete for RCC structural element upto floor three level including curing , compaction, finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of shuttering , centering and reinforcement for: Beams, suspended floors, roofs, girders having slopes up to 15degree, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircase and spiral staircases : M20 grade nominal mix/design mix Desc/Location Nos L B H 43 9.8.3Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 40 mm 44 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of column etc up to plinth level 45 9.6.4Providing and Laying in position of Cement concrete Nominal mix (1:1.5:3) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; 20 mm 46 P/F steel reinforcement for RCC work including cutting bending placing in position and binding complete including cost of binding wire in foundation raft footing step beams base of columns etc. upto floor three level .: Hot rolled deformed bar (IS : 1139) 47 7.1.2Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:4 48 PLASTER (Ceiling) 6 mm thick. Cement plaster to ceiling of mix 1:3 (1 cement : 3 fine sand) 49 8.13.2Flush or ruled pointing on stone masonry including racking of joints and curing etc. complete including all leads of all construction materials in mortar ratio. In Cement sandmortar 1:4 50 PLASTER (Internal) Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 20 mm thick. 51 5.9.1Extra charges for disposal of excavated/re-handled material in required profile laid in uniform layers and given side slopes well dressed having layer thickness including loading and un-loading wherever required with cost of dewatering wherever required complete in all respectNot exceeding 15cm 52 Painting with enamel paint of approvd brand and manufacture to give an even shade : Two or more coats on new work 53 18.17.2Providing and laying cement concrete coping in (1:2:4) with maximum size of crusher broken aggregate upto 20 mm including shuttering etc. with all leads of material complete in all respect in thickness of: 50 mm 54 Granding for roof water profing treatment with cement motor 1:4 (1 cement : 4 coarse sand) 2 inch thick 55 18.28.1.2Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458- 2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 150mm NP3 56 Polished Blue kota stone flooring Skerting, Laid over 20 mm thick base of cement mortar 1:4 and jointed with Grey cement Slurry to match of the Shade of the Slab including rubbing and polishing complete for area of each slab from 2001 to 5000 sq. cm. 25 mm thick slab 57 11.19Reaming, redrilling and pressure jet flushing of foundation holes of NX size, in the drainage gallery of dam, using diamond drill bit of suitable size, diamond reamer shell with using hydraulically operated rotary core drilling equipments, rods of suitable length to specified depth, fixing PVC pipes with caps, including cost of materials, hire charges of equipments, fuel, labour with all leads and lift etc. complete as directed by Engineer in Charge 58 Providing brick kharanja in cement sand mortar 1:4 in square pattren over roof of ground floor (75 mm to 100 mm thick avarage) Add for if cement mortar 1 : 4 is used instead of lime sand mortar 1 : 2. 59 18.50Cleaning drainage gallery, adits, instrumentation galleries etc. by scrubbing/ brushing including chiseling and removing leached lime deposit and disposing off all the waste materialoutside adits in specified location as directed etc., complete with all leads and lifts. 60 Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish 20 mm thick Add extra over item No. 12.7 to 12.10 for water proofing compound if used @ 2% of the cement by weight. 61 9.8.4Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sandmortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto 20 mm 62 Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4 ralthal, stone kharanja, lime terracing 90 mm avarage thickness [as per JAIPUR PRACTICE] with ceiling pointing in cement sand mortar 1:3 per specification for span:above 3.00 metre and upto 3.30 metre. 63 10.1.3Side shuttering including propping etc. complete (to achieve finish F 2 for :Retaining wall, counterfort, abutment, wing walls up stream or down- stream slope facings of dams and open faces of construction joints etc. 64 Providing and fixing T-iron frame for doors windwos and ventilators of mild steel tee-setions, joints mitred and welded with 15x3 mm lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 200 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butts hinges and screws and applying a priming coat of approved quality 65 10.9.2.2Supplying of M.S. reionforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leadsand lifts using. Tor or ribbed bars (IS :1786-1985) 66 window:Providing and fixing Ms sheet double leaf doors shutter in angle iron frame 35x35x5 mm suitabilly digonally braced with 25x3 mm flat iron above and below lock rail of size 50x5 mm beading extra including all fittings, as per direction of engineer incharge. M.S. Sheet 20 SWG 67 10.9.1Labour charges for steel reinforcement including bending, binding, and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts. 68 Doors:-Providing and fixing M.S. sheet 1 mm thick double leaf door shutter in angle iron frame 35x35x5 mm siutabilly diagonally braced with 25x3 mm flat iron above and below lock rail of size 50x5 mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chokhats: including two coats of anit-corrosive red oxide primer paint. M.S. Sheet 22 SWG 69 10.10.2Extra labour charges for RCC due to obstruction in laying and placing the reinforced cement concrete due to reinforcement. Columns, slabs, cantilevers projections staircases, lintels, beams, chajjas, Retaining walls, piers, abutments, galleries, arch covers, bed plates, sluice capstan bases etc. 70 Supplying & fixing fixed wire Gauge of 14 mesh X 24 Gauge to the Metal frame of rolled section by metal beading 20X3 with suitable screw at not exceeding 150 mm distance 71 5.8.1Re-handling of excavated material including loading unloading and dressing within initial lead of 50 m and lift of 1.5m with cost of de-watering wherever required and all applicabletaxes and levies etc. complete in all respect Earth / Soil 72 Providing and fixing square bars or other flat welded to window ventilators etc. 10mm x 10mm 73 5.18.2.2(ii)Compaction of earth or highly weathered strataBy mechanical equipment such as sheep foot roller/ pneumatic tyred roller/vibro compactor / vibro sheep foot compactor required as per site condition to obtain dry density of. at least 98% of Standard Proctor s density 74 Polished blue kota stone flooring skirting laid over 20mm thick base of C.M. 1:4 and jointd with grey cement slurry to match the shade of the slab including rubbing & polishing complete: for area of each slab from 901 to 2000 sqcm (a) 25mm thick slab 75 5.9.2Extra charges for disposal of excavated/re-handled material in required profile laid in uniform layers and given side slopes well dressed having layer thickness including loading and un-loading wherever required with cost of dewatering wherever required complete in all respect Not exceeding 20cm 76 Providing & fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 77 5.10.1Beyond initial lead of 50 m & upto 250 m 78 Finishing wall with water proofing cement paint of approved brand & manufracture and of required shade to give an even shade including all scafolding new work (three or more coats) 79 5.30Supplying and laying sand of grade as per design requirement in required profile including all lead & lifts.This item is to be used only for laying filter / inverted filter 80 White washing with lime to give in even shade including all scaffolding on new work (three or more coats). 81 5.31.2Supplying and laying aggregate in layers and profile as specified including all leads & lifts.This item is to be used only for laying filter / inverted filterBroken ballast 20 to 40 mm size 82 P & F rigid PVC pipe (IS 4985 Mark) Class 2nd / (4 kg / sqcm) approved quality / Make including jointing the pipe with solvant cement rubber ring and lubricant 110 mm dia. 83 11.14Prepration of old masonry surfaces before laying of further masonry or concrete over it by cleaning the surface and mortar joints with brushing and raking finally, washing by compressed air & water under pressure 84 PVC bend 110 mm 85 37 mm thick shotcrete by wet mix process, applied with compressed air gun after chipping of defective concrete / masonry, racking the joints, cleaning of surface thoroughly with wet sand blasting after fixing of 9 gauge good quality rust free welded mesh of size 50 mm x 50 mm in TWO layers with anchors / clamps. After racking the joints clean the surface thoroughy by wet sand blasting, anchor the first layer of welded mesh in position and apply 15 mm cement concrete (1:2:1) by pressure gun and after hardening of first layer, anchor second layer of welded wire mesh, apply 22 mm thick cement concrete complete in all respect. Cement concrete comprising of cement, sand, coarse aggregate, water and quick setting compound in the proportion 1:2:1, sand and coarse aggregate conforming to IS 383 and table no. 1 of IS;9012 respectively. 86 Pointing on stone masonry in lime sand mortar 1:2 (1 lime putty : 2 sand) : Raised and cut pointing 87 11.18Add extra over item No. 16 &17 for each subsequent height 3.00 m or part there-of above initial lift of 5 m from ground level (upward or downward) 88 P & F unplasticized poly choride (UPVC) SWR pipe fitting type B for sciland waste discharge system ( IS : 13592: 1992 marked) of approved quality / make 110mm dia 89 12.30.3Providing Rubber seals as per IS:11855 for Dam sluice, canal, barrage, stop dam etc. gates of required size and type and specifications with testing, including all lead and lifts, packing & forwarding charges for all components etc. complete. Rubber seal musical note type 100mmx44mm x14mm (44mm Bulb) Tefloncladded 90 P&F Indian type white glazed vitreous china Ist quality W.C. orissa pan (IS : 2556 mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor : size530x410 mm 91 12.40Labour charges for removal of existing wornout/damaged bottom and side rubber seal of Stop Log Gate of Dam by cutting bolts with gas cutter, providing holes in new rubber sealinsertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete 92 P & F WVC wash basin (Ist quality, I.S. : 2556 mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. pillar cock (IS : 8934 mark) & 32 mm C.P. brass waste coupling of approved make. 25 mm G.I. waste pipe complete including cutting & making good the wall : Size 450 mm x 300 mm 93 12.38Labour charges for removal of existing wornout/damaged bottom rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter, providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete. 94 P & F G.I pipes (internal work) with G.I. fittings (IS:1239 mark) & MS clamps including cutting and making good the walls and floors : Exposed on wall A (i) 15 mm dia nominal bore 95 5.28.1Watering of earth including cost of carriage of water when source of water is up to 1 Km 96 Painting with enamel paint of approvd brand and manufacture to give an even shade : One or more coats on old work 97 12.39Labour charges for removal of existing wornout/damaged side rubber seal of crest Radial Gates, Vertical Gates and Intake Service Well Gates of Dam by cutting bolts with gas cutter,providing holes in new rubber seal insertion of sleevs and fixing over gates with nut blots, washer ect including cost of gas (LPG and Oxygen) cylinder etc complete 98 P & F PVC storage tank (IS : 12701 marked indicating the BIS license No), of approved make with cover, 25 mm dia 1M long G.I. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design : 300 litre capacity. 99 12.31.2Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class B primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich rimer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.Beyond 1.5m height 100 P & F stop cock (IS : 8931 mark), superior quality & of approved make : brass 400 gm. 15 mm nominal bore 101 12.31.2Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class B primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich rimer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipments. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.upto1.5m height 102 P & F looking mirrors with P.V.C. frame of approved (Atul, Modi Guard , Saint Gobin or equivalent) size 500 x 400 mm 103 18.13Painting distance mark stone and lettering with light blue white or yellow un-washable paint including cost of material 104 P & F flush cock/flush valve (IS 9758 mark) for WC of approved quality make : CP brass half-turn exposed 25 mm nominal bore. 105 12.37Oiling and greasing of Crest radial gates,Vertical Gates and Intake Service well Gates of Dam including all charges of man and material complete, which include cleaning of wire rope with petrol / diesel and applying Cardium compound to wire ropes, oiling & greasing etc complete as per direction of Engineer-in-Charge 106 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20 mm thick insider plaster in cm 1:6 , finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring, earth work etc. complete as per design including disposal of surplus earth with in a lead of 50 mtr. inside size 300 x 300 mm depth up to 0.5 m cement cover with frame. 107 12.4Design, Drawing, fabrication, supply, erection, testing and commissioning of Vertical lift sliding type gate with frame consisting of skin plate, sealing frame, stiffeners, horizontal and vertical girders, guide, stainless steel flat/Brass flat, rivets,wedges, lifting rods etc., with all accessories as per relevant IS code including frame & gate complete set for Canal Cross, Escape, Head regulator /Tank head regulator includingcost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, seal fixing, tools and tackles etc., applying two coat of zinc rich epoxy primer to give dry film thickness of 70 5 microns and finish coat (two coats) of solvent less coal tarepoxy paint using airless spray to provide dry film thickness of 150 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., complete as per specifications and approved drawings with all lead and lifts, including packing & forwarding, transportation charges for structural steel components and other materials. 108 Construction of soakage well in all types of soil of approved drawing, top 90 cm. Portion in 450 mm thick masonry with cm 1:6, 80 mm thick stone slab covering, jointing of slab in cm 1:3, Ralthal, Kharanja 40 mm thick M-15 grade C.C. flooring, earth work etc. complete including disposal of surplus earth with in a lead of 50 mtr. inner dia 90 cm & 10 to 12 mtr deep 109 11.13Preparation of surface of existing concrete surface/ masonry in lime mortar/ cement mortar including removal of organic deposit by washing with etching compound and use of wet sand blasting and final washing the surface with air and water jet including cost of all material and equipment required for the work complete. 110 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm comfirming to IS : 13753 colour such as white, grey, ivory, fume red brown, light green, light blue and other lightshades in floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder (Untile or Roffe make) and finishing with flushpointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortar bed 1:4) Category-A : Kajaria, Jhonson, Somani make 111 12.52.1.11Providind of Rubber Seals as per IS 11855 for dams, sliuce, canals, barrage ,stop log gates etc of required size and type and specifications with testing , including all lead andlifts, packing and forwording charges for all components etc. complete in all respectRubber Seal Musical Knot, Solid Bulb type of Size 75mm 35mm x 10 mm 112 Add extra over item No 7.6.1 and 7.6.2 for using 400x400mm size MAT finished tiles inplace of 300x300mm size 113 12.52.1.9Providind of Rubber Seals as per IS 11855 for dams, sliuce, canals, barrage ,stop log gates etc of required size and type and specifications with testing , including all lead andlifts, packing and forwording charges for all components etc. complete in all respectRubber Seal Musical Knot, Solid Bulb with brass clading type of Size 100mm 45mm x 15 mm 114 Providing & fixing steel glazed doors, windows and ventilators with shutters of standred rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:2:4 (1-Cement:2-coarse sand:4-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steel handles and peg stay etc. as required. doors 115 12.49.2Oiling, Greasing work of gate parts like Headstock, Headstock parts, Roller Assembly, Operating Rod, Sealing Frame, Guide Tee with all Labor tools and tackles etc. and Materialfor vertical lift sliding type/ fix wheel gates excluding cardium compund and gear oil For gate size above 1 Sqm to 10 Sqm 116 Providing & fixing steel glazed doors, windows and ventilators with shutters of standred rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded incement concrete blocks 15x10x10 Cm. of 1:2:4 (1-Cement:2-coarse sand:4-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, ormetal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steelhandles and peg stay etc. as required.windows sidehung(openable) 117 5.33Supplying and laying quarry spalls properly graded but not more than 10cm in size with spreading in required profile including all leads & lifts 118 Distempering with oil bound washable distemperr of approved brand and manufacture to give an even shade including all scaffolding : old work (one oe more coats) including scrapping surface and necessary repairs (a) colour change 119 12.36Operation of vertical / radial gates, hoist operation, stop log gates, Gantry Crane, mono rail etc. at Dams for all seasons round the clock whenever required, as per direction of Engineer in-Charge, by providing sk illed & semi skilled staff well conversant with the work of operation of gates as well as meet out all types maintenance & repair work of gates whenever required in any emergency during operation of the gates including deployment of Chowkidar at gate section of the Dam 120 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding : New work (two or more coats) over and includingscrapping and priming coat with cement primer 121 5.2.2Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect.Hard rock not requiring blasting 122 P & F bib cock (IS : 8931 mark), superior quality of approved make : Brass 400 grm, 15 mm nominal bore 123 18.1.2Cutting & clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. Thick 124 P&F sand cast iron (S.C.I.) Pipe (IS:1729 mark) of approved make in wall in floor with MS holder bat clamps in 10X10X10 cm. M15 grade concrete block joints filled with CM 1:4 with spun yard including cutting holes and making good the wall.150mm dia. 125 17.5.2Demolishing stone rubble masonry including stacking of usable material and disposal of unuseable material within 50 meters lead inclusive of de-watering wherever required.In cement mortar 126 P&F SCI fittings (IS1729mark) in CM 1:4 spun yarn150mm w/o door Bend 127 5.2.3Excavation including loading unloading disposal and dressing of excavated rock within initial lead of 50m and lift upto 1.5m in dry or moist including dressing of excavated area, dewatering wherever required complete in all respect.Phylite & other hard rock requiring nominal blasting 128 spray painting with flat wall paint of approved brand and manufacture to give an even shade : two oe more coats on new work including priming coat of distemper primer of approved brandand manufacture 129 11.2.1Drilling 35 mm.to 48 mm. Dia holes in all types of rock or artificial hard material like concrete or masonary for consolidation/ curtain grouting in stages by percussion drillingincluding cost of drilling equipment, compressed air, water etc. complete & re-drilling in the hole through set grout, if required.Up to 5 m. depth 130 S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 131 11.2.2Drilling 35 mm.to 48 mm. Dia holes in all types of rock or artificial hard material like concrete or masonary for consolidation/ curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete & re-drilling in the hole through set grout, if required.From 5 to 10 m depth 132 S&Providing & Fixing of ISO certified company made off load change over switch four pole/two pole, 230/ 415 V ,side handle operated conforming to IS:13947 P-III in sheet steelenclosure complete with connections with lugs, testing etc. as required in the following rating: All as per pre approved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure A attached with this BSR . 32 A, Four poleF following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according toIS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 133 2.9.2Cement OPC (in bags) 50 Kg in weight. As per IS 1489 and IS 8112 (excluding cost ofempty begs). 134 S&PP & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nutand bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSRroviding & Fixing of ISO certified company made off load change overswitch four pole/two pole, 230/ 415 V ,side handle operated conforming to IS:13947 P-III in sheet steel enclosure complete with connections with lugs, testing etc. as required in thefollowing rating: All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 A, Four poleFfollowing sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. dia 50mm 6.4 mmthick 135 10.2Centering and shuttering for slabs, beams, lintels Columns, trough with or without caps and base including propping and remove 136 P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. For additional technical parameters of product / work refer Annexure Aattached with this BSR 9 mm thick 137 11.1.1.1Drilling holes of 35 mm diameter for anchor rods.Upto 1.50 m. depth 138 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity(B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulsewithstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimumphase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including makingconnections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure A attached with this BSR (a) 6 Amp to 32 Amp rating 139 5.35.3Supplying stone, spall and laying R. R. stone pitching, hammer dressed with packing ofvoids from small stones including all lead & lifts, in required profile of 23 cm thickness ( 5 % thickness tolerance) 140 Providing corrugated G.I. Sheet roofing fixed with G.I.J. or L hooks bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coat of approved paint on over lapping of sheet complete (upto a pitch of 60o) & excluding the cost of purlins rafters and truses, for class of sheets :1.60mm thick 141 11.1.2Labour charges for Fixing of anchor bars in neat cement grout including cost of cement and curing etc. complete 142 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contactprotection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDAaccrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Triple pole MCB 50/63 A rating 143 11.1.3Supply of Tor steel anchor bars of required diameter, length and shape at site of work complete. 144 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contactprotection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR (c) Double pole MCBS of 50 AMP to 63 AMP 145 12.7Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity manually operated rope drum hoist according to relevant IS code, consisting ofhoist platform bridge, rope drums, connecting shaft, gear system unit, pulleys, wire rope, Gate position indicator, manual operation system, etc. complete, with all accessories for operating gates including cost of all materials, machinery, labour, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oil filling, tools and tackles, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings, including packing & forwarding, transportation charges for all materials. 146 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel /CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including makingconnections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 4 way Metal door (single phase) 147 12.1.1Design, drawing, fabrication, supply, erection, testing and commissioning of Embedded parts consisting of sill beams, vertical tracks, vertical seal tracks, sealing frame, guide tracks/rails, wall plates, seal seats, anchors, anchor girders, yoke girders, tie flats, trunnion supports, rope and pulley supports etc. and any required necessary item, with all accessories as per relevant IS code, for all type radial gates/ Vertical lift fix wheel type sluice and Canal gates/Stop log gates including cost of all materials, machinery, labour, cutting,aligning, anchoring, welding, finishing, cleaning, tools and tackles, applying two coat of zinc rich epoxy primer to give dry film thickness of 70 5 microns and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thicknessof 150 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., including packing & forwarding, transportation charges complete item, as per specifications and approved drawings 148 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (metal / Glazed )Distributio board with Metal end box made out from Galvanized steel /CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure A attached with this BSR 12 way Metal door (single phase) 149 18.49Under water videography of dam body & its appertunance i.e gates, under sluice, emergency gate grooves clearly showing location defect area or area of interest indicatingcondition from all possible angles and special focus on damaged portions complete in all respects upto the satisfaction of Engineer in charge. The work also includes supply of three sets of video in digital form and a depth wise report prepared in hard copy 150 Providing & fixing in position frame made out of MS angle (riveted or welded) finished with two coat of red oxide and enamel paint of following size as required 38*38*6 mm 151 12.8.1Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity manually operated screw type hoist according to relevant IS code, consisting of supporting structure, platform bridge etc., operating handle, gate positionindicator, plumber block, couplings with all required accessories for operating Head/cross/escape regulator gate including cost of all materials, machinery, labour, tools and tackeles, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oiling, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings with all lead and lifts,including packing & forwarding, transportation charges for structural steel components and other materials. 152 Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. systemlumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0. 95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintanedtill life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall besubmitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .600mm , Min. Lumens output 1800 lm LED Tube rod with Polycarbonate Housing 153 5.15.1.1Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all typessoils/ saturated soil such as morrum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m 154 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating ,minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Four pole 100/300 mA sensitivity 40 A rating 155 7.1.3Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation includingcuring with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:5 156 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulationPVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connectionswith Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parametersof product / work refer Annexure A attached with this BSR 1 *2.5 sq.mm 157 9.3.1Providing and Laying in position of Cement concrete Design mix M-25 including leads of all construction materials, plasticizers (if required), curing, compaction and finishing withrendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher brokenstone aggregate of maximum size upto;(For mix design Cement content considered 420 kg/ cum of concrete) 150 mm 158 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connectionswith Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own inhouse NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 1*6.00 sq.mm 159 7.10.2Brick masonry (using well burnt clay bricks of size 230 x 110 x 70 mm, class designation 75 as per specification) up to plinth including all leads of all construction materialsincluding curing etc. complete. In cement sand mortar 1:4 160 Supply and erection of GI stay set confirming to pattern-1 of BS:16/1974 and as per latest Discom Specifications complete with stay rod with anchor plate fitted with cast iron crosshead and steel bow, in cement concrete 1:3:6 including excavation of pit-re-filling etc complete as reqd. All as per pre approved by Engineer in charge.For additional technicalparameters of product / work refer Annexure A attached with this BSR. Stay set of dia 16mm,1.8m long stay rod and anchor plate 300 x 300 x 4.0 mm 161 5.26Threading / turfing of grass on slopes of bunds etc. in rows 15 cm centre to centre in each direction including Ploughing, levelling, breaking of clods, and removal of stones etc. ifrequired including maintenance for 30 days or more till the grass develops fully with all leads and lifts complete 162 Add extra over item No. 10.25 for providing and fixing CGI sheets in curved roofing 163 8.2.1Plaster in cement sand mortar 1:4 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materials of thickness: 20 mm 164 Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discomsstandard specifications,suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 100 mm x 70 mm 165 10.1.110.1 Supply, installation, testing and commissioning of MNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility ScaleSolar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR,showing arrangement of panel in available space, installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably designed towithstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of more than 98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in stringlevelmonitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive.The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document.10.1.1 Solar panels up to 10 KW at a single location. 166 Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure Attached with this BSR 30 Sqmm of (6+1) 2.59mm (Weasel) 167 16.12Hire charges of DGPS instrument with operator and staff for bench mark shifting, topography survey, command area survey, canal survey, dam survey etc. and collection ofdata, plotting the details and preparing digital map of area in layers, and developing contours where ever required as directed by engineer in charge; including supply of detailed drawingsin appropriate scale in soft copy & three sets of Hard copy complete in all respect. These rates are including all types of taxes applicable 168 Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fireresistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure A attached with this BSR 169 16.14.1.3Transfer of Dam / Canal alignment from sajra map to the ground and taking Levels by Auto level or DGPS, develo ping L-section and X-section and submitting in hard copy threesets and soft copy in Auto Cad format, using layer system, showing all features. (Total length of L-section and X-section to be measured for payment) L-section of Dam/ Canal (ii) InPlain area - Levels for L-section to be taken at interval 30 meter. 170 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tubeincluding side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Suitable for 2 LED Tube shape fixture for single rod 171 16.14.2.3Transfer of Dam / Canal alignment from sajra map to the ground and taking Levels by Auto level or DGPS, developing L-section and X-section and submitting in hard copy threesets and soft copy in Auto Cad format, using layer system, showing all features. (Total length of L-section and X-section to be measured for payment) X-section of Dam/ Canal(Total length of X-section shall be measured) (ii) In Plain area - Levels for X-section be taken at interval 5meter 172 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B classwatering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lidsuitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternatelayers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter inmeasurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 173 16.10Grid survey at interval of 30 x 30 meter to conduct submergence survey with TS / DGPSinstrument and prepare 0.50 m interval contour plan and superimposing over khasra map including all ancillary works as described in specifications and conditions of contract. Note: Khasra map will be provided by Department Marking of existing FRL, MWL, MDDL contours and dam alignment. Prepare area-elevation and storage -elevation curves andtables. 174 Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0. 95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall besubmitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing 175 16.6.1Digitization of Jamabandi and providing excel sheet to the department Note: Jamabandi Register will be provided by Department 176 SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H & I 62.5 KVA at 0.8 pf 415V 50Hz 3-ǿ 177 16.6.2Digitization of Khasra map with details in layers and providing soft copy (acad file) Note: Khasra map will be provided by Department 178 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter& Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults,UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturershall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ wo rk , refer Annexure A attached with this BSR . 50 to 82.5 kva 179 5.10.4Add extra for each subsequent lead of 1 km or part there of beyond 5 Km 180 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR i- shortpoint (upto 3 Mtr) 181 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR ii - Medium point (upto 6 Mtr) 182 11.5.1Drilling more than 48 mm but upto 76 mm dia, holes in over burden hard soil compacted earth, morrum etc. for consolidation / curtain grouting in stages by percussion drilling including cost of drilling equipment, compressed air, water etc. complete and re-drilling in the hole through set grout if required.Up to 5 m. depth 183 Structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr height.In flats, tees, angles and channels. 184 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mmnominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS: 694) in recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its ISI marked (IS:14768P-II 2003) accessories, round tiles,Hot Dipped Galvanized Modular Box of 1.2 mm thick with earth terminal, 10A Modular switch,3 pin ceiling rose / holder / 3 way connector ,Modular faceplate with grid plate, pvc bushes, check nuts, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR iii - Long point (upto 10 Mtr) 185 Rewiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988)accessories, 1.2 mm thick MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy /Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR :on board 186 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity(B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulsewithstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2,low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 40A rating 187 P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fanhook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 188 Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirementslaid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure A attached with this BSR . 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 189 Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 180 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial gradePolycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure A attached with this BSR . 190 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tubeincluding side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure A attached with this BSR 191 Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI>70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 9 watt 192 P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nutand bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR : 4.8 mm thick 193 Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brassterminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work ,refer Annexure A attached with this BSR 194 providing of 18mm wire rope galvanised 6x36 construction IWRC (steel core) RHOL (right hand ordinary lay) & tensile strength of 1960 N/mm confirming to IS :2266/89 195 Chair type 7 {Revolving chair medium back, support backrest symmetrical lumber support, back cover mesh fabric) (inclusive all taxes) 196 Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m. 197 Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; handpacking, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up theinterstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&Hspecification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete : Crusher broken Grade II (63-45 mm) 198 Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in concrete mixer, laid manualy, compacted with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specificationincluding all material, labour, machinery, lighting, guarding and maintenance of diversion 199 Chair type 4 {chair type with arms,frame type 4 legs,castors without (inclusive of all taxes)} 200 Providing and laying un-reinforced, dowel jointed, plain cement concrete mix With Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fineaggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuousoperation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour,machinery, lighting, guarding and maintenance of diversion. PCC M-25 201 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be rovided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow raceability/authenticity. Fixture shall be IS 10322 Complianced. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures . (LM79/LM80) certificate/report with liable warranty of product/accessories from OEM shall be submitted . All as per approved by Engineer In charge . for additional technical parameters of products/works . High Power LED Flood 202 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S tube 203 Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. 4 meter 204 Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved byEngineer in charge. For additional technical parameters of products/ work . Double arm overhang 205 providing of 24 mm wire rope galvanised 6x36 construction IWRC (steel core) RHOL (right hand ordinary lay) & tensile strength of 1960 N/mm confirming to IS :2266/89 206 Supply installation testing & Commissioning of ISO certified company made high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK /IS:875 Part-1 –2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, inte gral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. ( See table P - 03 for specs.) OEM must have type test certificate for wind tunnel test for high mast fixtures , complete in all respect .All asper pre approved by Engineer in charge ,for additional technical parameters of products/work. 16.0 Mtr HM(in 2section) 207 Labour charge for removing old wire ropes and fixing of new wire ropes with all accessories and T&P etc complete 208 oiling & greasing of gantry crane on Parbati Dam Which includes complete Removal of all old worn out & broken down parts, cables, connections etc complete checking of all copper wiring, all wiring & connections control panel , all switches etc complete with all material , labout, T&P and lead and lift complete in all respect 209 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approvedbrand or manufacture 210 Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic vibrio pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and braking load etc. as per BS 6717:2001, Grey cement. : 80mm thick 211 Table type 3 (storage provided one side,length of table top-1200 mm, depth of table top-600 mm) 212 Providing sofa set(Frame covering fully upholstered, Total No of seats in sofa set -4, covering material for seat and back rest-leatherite) 213 Table type 5 (seating capacity - 8 seater, width in mm -1200, Length in mm - 2400mm, shape of table top Rectangular , height in mm - 750 mm ) (inclusive all taxes)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
48.
Drinking Water Supply and Sanitation #10236715 Price Bid
Augmentation Cum Reorganization Of Aapni Yojana Phase I Churu Bisau Feeder Water Supply Project Including 10 Years O And M District Churu.- 1 Part A : Cost Estimate For Pipeline Works 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 75 Mm Dia 4 90 Mm Dia 5 110 Mm Dia 6 125 Mm Dia 7 140 Mm Dia 8 160 Mm Dia 9 180 Mm Dia 10 200 Mm Dia 11 225 Mm Dia 12 100 Mm Dia 13 150 Mm Dia 14 200 Mm Dia 15 250 Mm Dia 16 300 Mm Dia 17 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-7 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 18 100 Mm Dia 19 150 Mm Dia 20 200 Mm Dia 21 250 Mm Dia 22 300 Mm Dia 23 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-9 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 24 150 Mm Dia 25 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpe Pe- 80 Pn-6 Isi Marked Pipes As Per Is-4984:1995 ( Ammended Upto Date ) With Neccessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe By Butt Fusion / Electro Fusion Welding Method, Including All Taxes, Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bends Etc. ) , Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earthwork ) 26 75 Mm Dia 27 90 Mm Dia 28 110 Mm Dia 29 125 Mm Dia 30 140 Mm Dia 31 160 Mm Dia 32 180 Mm Dia 33 200 Mm Dia 34 225 Mm Dia 35 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Combination Air Release Valve Kinetic Type With Single Chamber Housed Double Orifice And Have 3 Functions, Large Air Exhaust, Small Air Venting And Large Air Intake During Vacuum Of Pipeline Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications:Governing Standard - Awwa C512 , Body And Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float & Internal Trim: Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbrdrilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside Fasteners - Cs / Galvanised Steel , Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, Big Orifice Size Should Be Equal Or Larger Than The Inlet Flange Bore, For Fully Comply With Awwa C512. ) , Valve Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge.Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. 36 50 Mm Dia 37 Construction Of Air Valve Pillar For Fixing Of Air Valves 38 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 39 100 Mm Dia 40 150 Mm Dia 41 200 Mm Dia 42 Providing, Lowering, Aligning, Fixingin Positionin Pipeline, Cid / Fsluicevalvesof Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss, Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitablesupport Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Manually Operated Ci Sluice Valves Of Class Pn 1.0 Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 43 80 Mm Dia 44 100 Mm Dia 45 125 Mm Dia 46 150 Mm Dia 47 200 Mm Dia 48 250 Mm Dia 49 300 Mm Dia 50 Cosntruction Of Valve Chamber For Sluice Valves, Flow Control Valve And Butterfly Valve As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 51 Type - A ( 80 Mm To 100 Mm Dia ) 52 Type - B ( 125 Mm To 200 Mm Dia ) 53 Type - C ( 250 Mm To 350 Mm Dia ) 54 Construction Of Village Transfer Chamber As Per Approved Design, Drawing & Specification Given For Material Of Construction And Completion Of All Works Of Installation Of Sluice Valves, D.Joints, C.I. Pipes, Specials ( Excluding Supply ) Etc. Complete In All Respect To Achieve The Work As Given In The Scope Of Work. 55 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 56 100 Mm Dia 57 150 Mm Dia 58 200 Mm Dia 59 250 Mm Dia 60 300 Mm Dia 61 Construction And Commissioning Of Rcc Intze Type Over Head Service Reservoir Of Following Capacity And Staging As Per The Scope Of Work And Technical Specifications, Consisting Of The Following Main Activities: - 62 A ) Topographic Survey, Preparation Of Site Contour Plan, Conducting Sbc Testand Its Approval From Departmentbefore Construction. Submission And Approval Of Concrete Mix Design And Water Quality Test Report For Water To Be Used In Construction. B ) Excavation In All Types Of Soil, Pcc Below Foundation, All Rcc Work, Plinth Protection All Around The Structure Including All Material, Labour, Shuttering, Scaffolding Etc.C ) Ohsr Shall Be Provided With Adequate Plinth Protection All Around The Structure In A Width Starting From Edge Of Structure At Gl And Extending At Least Up To 1.0M Beyond The Edge Of Outer Most Projection Of Ohsr.The Plinth Protection Shall Consist Of 150Mm Thick Pcc In M-15 Grade Concrete Laid Over 150Mm Thick Layer Of Compacted Soil.D ) Providing And Applying Two Coats Of Food Grade Epoxy Paint On The Inside Surface On The Top Dome, Edge Beam And 600 Mm Height Of The Vertical Wall.E ) Conducting Successfully Hydro Test And Water Tightness Test As Per I.S. Code.F ) Providing And Applying Three Coats Of Anti-Carbonation Paint On The Top Surface Of The Top Dome.G ) Providing And Applying Three Coats Of Cement-Based Paint On The External Surface Of The Container, Balcony, Cone Wall, Columns & Beams Etc..H ) Providing And Fixing Ss-304 Ventilator, Ss 304 Manhole Frame And Cover And Ss-304 Ladder From Top Dome / Slab To Bottom Dome / Slab Inside Container. I ) Providing And Fixing Of Ms Section Ladder From The Last Landing To Balcony Having Railing All Around It And Ms Ladder With Safety Cage From Balcony To Top Dome / Slab.J ) Providing And Fixing Water Level Indicator ( Float Type ) . 63 K ) Providing And Fixing Of Hand Railing All Around The Balcony, Top Dome And Staircase Consisting Of 25Mm Diameter Class-B Gi Pipe In Two Rows And 1000 Mm High, 50X50x6mm Angle Iron Vertical Post At A Maximum Spacing Of 1500Mm Centres.L ) All Ms Parts To Be Painted With Two Coats Of The Enamel Paint Over The Primer Coat Of Red Oxide.M ) Providing And Fixing Of 150Mm Wide Pvc Water Bar For The Construction Joints In The Container ( Vertical Wall & Cone Wall ) .N ) Providing One Aluminium Portable Ladder Of Appropriate Length To Access First Landing ( 3.5 To 4.5M Above Gl ) From Ground.O ) Lighting Arrestor Consisting Of Providing And Fixing Of 2 Nos.Of Chemical Earthing And Connecting It To The Conical Cover Of Ss Ventilator With Two Separate Gi Strips Of 50Mmx3mm.P ) Ci / Di Puddle Collar Shall Be Fixed In The Bottom Dome / Slab For Connecting Inlet, Outlet, Overflow And Washout Pipe Of The Reservoir.Q ) Painting The Name Of The Scheme And Other Details On The Reservoir, And Any Other Work Related To Structure As Per The Directions Of Engineer-In- Charge, Technical Specification And Scope Of Work.R ) Inlet, Outlet, Overflow, Washout Pipes And Valves Are Not Included In This Work, Provision For The Same Shall Be Taken Separately. 64 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 18 M 65 100 Kl 66 150 Kl 67 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 20 M 68 100 Kl Each ( 100 X 2 Nos. ) 69 200 Kl Each ( 200 Kl X 3 Nos. ) 70 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 71 100 Mm Dia 72 150 Mm Dia 73 200 Mm Dia 74 Construction Of Boundary Wall Of Brick / Stone Masonary As Per Enclosed Ga Drawing, Scope Of Work And Technical Specifications Complete Work In All Respect. Brief Details Of Boundary Wall Parameter Is As Below:1. Depth Of Foundation- 900 Mm.2. Pcc In M-10, Width -900 Mm And Thickness 100 Mm, 3. Section Of Foundation Above Pcc W-600 Mm, D-450Mm, W- 450Mm, D-450 Mm.4. Superstructure Work: Stone Masonary W-300, Height-1650 Mm, / Brick Work W-230 Mm, Height- 1650 Mm.5. Cement Mortar Pointing On Stone Masonary And Cement Mortar Plaster 20 Mm Thick On Brick Masonary In Cm 1:6.6. Expansion Joint Shall Be On Every 30 Mtr.7. On Top Of Wall There Shall Be Cc Coping 75 Mm Thick ( 1:2:4 ) Shall Be Provided.8. Pillar For Main Gate 350X350 Mm In Size Is Part Of Boundary Wall.9. Cement Paint Of Approved Colour In 3 Coat Shall Be Done. 75 Providing And Fixing Steel, Gate, Grating And Grills Made Of Angles, Tees, Square Bars, Flats Or Black Pipe With Hold Fast And Fitting Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide And Two Coat Of Enamal Paints. 76 Dismantling Of Cement Concrete Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Cutting The Peripheral Edge By Cc Cutter, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shallbe Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks As Per Technical Specification And Scope Of Work. 77 Providing And Laying In Position Cement Concrete M10 Grade Nominal Mix 1:4:8 ( 1 Cement : 4Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) In Base Course Complete Including All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. 78 Providing And Laying In Position Cement Concrete In Specified Grade Over Prepared Base Course Complete Including Finishing, Curing, All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. M20 Grade Nominal Mix1: 1.5: 3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size ) . 79 Dismantling Of Flexible Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Madefor Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks Per Technical Specification And Scope Of Work. 80 Bituminous Courses 81 Granular Courses 82 Provision For Restroration Of Bitumen Road After Laying & Jointing Pipe Line As Per Direction Of Engineer In Charge 83 Provision Forrestoration Of Wbm Road Cutting As Per Specifications. 84 Total Length Of Canal Corssing During Laying Of Pipe At Various Locations 85 Providing Service Connection As Per Technical Specification And Standard Drawing As Per Relevant Is Code ( Ammended Up To Date ) From All Kind Of Water Mains Up To Consumer Meter / Premises ( Complete Job ) . This Job Includes Digging Out Suitable Size Of Pits And Trench For Laying Service Line In All Kinds Of Soil Including Demolishing Of Cement Concrete, Wbm, Black Top Etc. Of All Thickness; Cutting Of Cc Road / Jhiri By Using A Concrete Cutter Machine; Depositing And Refilling Of Pit & Jhiri Watering And Ramming / Compacting In Layers And Disposal Of Surplus Excavated Soilas Directed With In A Lead Of 50 Meter; Providing And Fixing Of All Fitting Duty Approved In Accordance With Iso / Dtr 9080 As Per Specification For Portable Water Including Approved Make Of Ms / Pvc Clamp With Saddle Piece, Gunmetal Ferrule 4.0 Mm ( Isi Make ) , Valve ( Is: 778 ) And Specials With Mdpe Pipe Pe 80 Pn 12.5 As Per Iso 4424 Below Ground Level And P&F Gi Pipe 15 Mm Dia Class B ( Isi Mark ) Above Ground Level In The Premises For Fixing Tap ( Max. Length2.0 Mtr. ) , P&F A 15 Mm Bib Cork With Foam Flow Chrome Plated With Complete Brass Body Including Brass Handle Having Good Quality With Wt 300 To 325 Gm, Including Accessories With Flushing , Cleaning, Disinfecting And Testing Of Pipeline Complete Required For Making Of Service Connection Complete In All Respect Including Labour Charges. In Addition To The Ferrule, An Orrifice Of 4.0Mm Dia Should Also Be Provided In The Service Line At The Entry Pointy Of ConsumerS Property In Such A Way That It Should Be Accessible For Inspection To Vwsc, Phed And Any Other Authority Which Woyld Like To Inspect As And When Required. The Service Line Should Be Laid Atleast 45 Cm Below Ground Level, Except In Case Of Concrete / Bituminous Raods Where Minimum Depth Shall Be 20Cm. For Details Specifications Of Mdpe Pipes Please Refer Technical Specifications Of Bid Document. General Specifications Of Mdpe Pipes Shall Be As Under: The Raw Material Shall Be Virging Pe 80 Blue Compound And Comply With The Requirement Of Iso / Directive Of Testing Material : 9080 With Minimum Required Strength Of 8 Kg / Sq.Cm. ; The Raw Material Shall Be Food Grade Quality ; Ressure Rating Shall Be 12.5 Bar ; The Pipes Shall Bear Iso Marking 86 Removing& Re-Fixing Of Precast Concrete Interlocking Blocks By Manual, Stacking Of Serviciable & Non Serviceable Material Separately. Disposal Of Dismantled Material Lead Up To 50 Mtr. The C.C. Interlocking Paving Blocks Be Laid On Average 25 Mm Thick Bed Of Coarse Sand And The Joints To Be Filled With Fine Sand. Laying Procedure On Compacted Sub Base As Defined. Complete Job Is To Be Executed As Per The Directions Of Engineer In Charge. The Rates To Be Inclusive Of Fixing Of Minimum 70 Percent Reusable Precast Concrete Interlockingblock And Cost Of Required New Precast Concrete Interlocking Block Against Damaged, Including Alllead And Lift As Per Technical Specifications. ( Interlocking Blockmanufactured By Fully Computerized Automatic Stationery Hydraulic Vibro Pressed Machine & Full Computerized Automatic Batching Plant Of Class A-1 As Per Bs:6717-2001. Tensile Splitting Strength And Breaking Load As Per Bs: 6717-2001Colour: Grey Cement Natural Colour. Variation In Dimension : Less Than 1.6 Mm Variation In Thickness: Less Than 3.2 Mm ) 80 Mm Thick 87 Add Extra Over Item No 1.21 & 1.22 For Providing20 Mm Pe80 Pn 16 As Per Iso 4427 Mdpe Pipe Including Excavation, Providing, Laying & Jointing Of Service Line Above 5.00 Mtr. 88 Supply Laying And Pushing Of Ms Casing Pipe Of Specified Thickness Approved By Concerned Department Authority By Trenchless Method Adopting Any Suitable Technology Below Ground At Required Depth Under Running Traffic Condition As Per Highway / Railway Standard Including Carrying Out Survey Work At The Job Site For Determining Underground Cable Trenches Like Telephone, Cable, Water & Sanitary Lines And Resistivity Test For Finding The Soil Strata Using Necessary Equipments For Completion Of Works, Mobilizing Of Machineries And Specialized Crew At The Job Site Complete In All Respect, Including Excavation Of Driven Pit And Exit Pit ( Up To 3 Meter Depth ) With Proper Protection At These Sites With Shoring Sheets And Ismb. Providing Ms Cutting Edges For Front Shield And Constructing Thrust Bed At Designated Level. Necessary Dewatering And Providing Concrete Foundation At The Base Of The Driven Pit, Pvc / Rubber Saddle As Per The Requirement Of Highway / Railway Authority, Crane For Handing Of Pipe And Any Other Machinery, Tools, And Tackles Required, Construction Of Temporary Works As Per Design, Drawing And Method As Per Approved Byauthority Specification And The Direction Of The Engineer.Apply Corrosion, Resistant, Protection On Inside And Outside Of Casing Pipeas Per Technical Specification. 89 300 Mm Dia 8 Mm Thick Casing Pipe With Protective Coating. 90 Part B : Pump House & Cwr 91 Fabrication, Supply Of Flanged / Plain Ended Ms Pipe Made From Ms Sheet Strips Of Relevant Is Specification Of Approved Thickness By Welding, Lowering, Laying, Aligning, Fixing In Position At All Level / Depths In Trenches Complete Excluding Flanged Jointing Wherever ( Required ) Including All Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer. 92 Ms Pipe Upto 600 Mm Dia ( With Minimum 5Mm Thickness Sheet 93 Ms Pipe Above 600Mm Dia ( With Minimum 6.3Mm Thickness Sheet ) 94 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 95 100 Mm Dia 96 125 Mm Dia 97 150Mm Dia 98 200 Mm Dia 99 250 Mm Dia 100 300 Mm Dia 101 450 Mm Dia 102 500 Mm Dia 103 600 Mm Dia 104 700 Mm Dia 105 900 Mm Dia 106 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 107 100 Mm Dia 108 125 Mm Dia 109 150 Mm Dia 110 200 Mm Dia 111 250 Mm Dia 112 300 Mm Dia 113 450 Mm Dia 114 500 Mm Dia 115 600 Mm Dia 116 900 Mm Dia 117 1000 Mm Dia 118 Cosntruction Of Valve Chamber For Sluice And Butterfly Valves As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 119 Valve Chamber ( 80 Mm To 100 Mm Dia ) 120 Valve Chamber ( 500 To 600 Mm ) 121 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Di D / F Resilient Seated ( Soft Seated ) Short Body Pattern Type Double Eccentric Butterfly Valves Of Approved Make Of Following Class & Dia Complete Confirming To Bs En 593 / Bs 5155 / Is 13095 / 1991 Amendedup To Date And Of Following Specifications: Body, Disc And End Cover Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Face To Face Dimensions As Per Din 3202 F4 / Is 13095Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Both Body And Disc Inside And Outside. Disc Seal Ring Of Epdm / Neoprene ( Food Grade Quality ) And Disc Seal Retaining Ring Of Ss / Cs. Shaft Of Ss- Aisi- 304 / 316 & Shaft Bearings-Bronze / Ptet Or Teflon With Epdm / Nbr O Ring Seal, Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge.Class Pn 1.6, Motorised Operatednote: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 122 100 Mm Dia 123 150 Mm Dia 124 250 Mm Dia 125 450 Mm Dia 126 500 Mm Dia 127 600 Mm Dia 128 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.6 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 129 100 Mm Dia 130 125 Mm Dia 131 150 Mm Dia 132 250 Mm Dia 133 450 Mm Dia 134 500 Mm Dia 135 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.0 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specificationsand As Per Direction Of Engineer. 136 600 Mm Dia 137 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq 138 295.08 Lps, 59 M Head 139 295.08 Lps, 80 M Head 140 274.12 Lps, 61 M Head 141 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq. 142 25.79 Lps, 70 M Head 143 26.83 Lps, 75 M Head 144 15.14 Lps, 79 M Head 145 Providing, Installation, Testing And Commissioning Of Centrifugal Monoblock Pump Set Conforming To Is 9079 Operating At Sync. Speed 2900 Rpm With Requisite Moc Impeller, Priming Funnel, Cock, Suitable Flanges At Suction And Delivery Side. Pump Shall Have Common Shaft For Pump And Motor. Motor Shall Be Suitable For Working On 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor Shall Be Tefc Type And Pump Set Shall Be Suitable For Working At Various Discharge And Head Requirements As Per Scope Of Work. Pump Shall Be Erected Onc.C. Foundation / Cross Channels / Rsj Frame Block With Suitable Foundation Bolts Grouted In C.C. Foundation Block Etc. Complete In All Respect As Perspecification, Scope Of Work And Direction Of Engineer In Charge Of Following Power Rating, Suitable For Prescribed Duty Conditions Mentioned In Td. 146 19.31 Lps, 41M Head 147 20.62 Lps, 54 M Head 148 9.93 Lps, 78 M Head 149 26.15 Lps, 44 M Head 150 18.46 Lps, 62 M Head 151 9.39 Lps, 73 M Head 152 Supplying, Erecting, Testing & Commissioning Of Electrically Operated Travelling Crane ( Eot ) .Main Girder & End Carriage Fabricated From Rollled Steel Section, Gear Box For All Motion, Electro Magnetic Friction Disc Type Brakes, All Safety Limit Switches, Lt Wheels En 9, Double Flanged 4No, With Sq. Cage Motor Of Adequate Rating ( Kw ) , Duly Painted Mechanical Cleaning And One Coat Of Primer And Two Coat Of Synthetic Paint And As Per The Direction Of The Engineer. 153 Span 7 M 6 Mtr. Lift 154 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Ci D / F Sluice Valves Of Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200 Stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss , Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxicsuitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitable Support Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-Incharge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Ci Sluice Valve Of Class Pn-1.0 155 100 Mm Dia 156 600 Mm Dia 157 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 158 100 Mm Dia 159 600 Mm Dia 160 700 Mm Dia 161 Design & Construction Of Clear Water Reservoirs Of Required Capacity At Following Places, Including Its Piping, Fittings, Etc Complete In All Respect As Per The Scope Of Work & Specifications Given In The Tender Document At The Following Places & Sizes . 162 Tps / Cps Bhaleri 163 Design, Manufacturing And Supply Of Batch Type Electro Chlorinator Of Capacity As Per Requirement Of Site 164 Part : C Repair Works 165 Repair Of Valves From Karamsana To Bhaleri 166 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Di Body Flanged End Tamper Proofkinetic Air Valve Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications: Governing Standard - Awwa C512 / Is:14845:2000 ( Amended Up To Date ) Body, High Pressure Cover , Low Pressure Cover, Cowl Andjoint Support Ring - Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float- Lp Ball & Hp Ball : Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbr , Hp Orifice & Hp Orifice Plug : Bronze / Ss , Bush: Bronze , Flanges As Per Is / Bs, Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside .Fasteners - Cs / Galvanised Steel, Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, With Di Metal Seated D / F Non Rising Stem. Sluice Valves As Per ( Is: 14846 Amendedupto Date ) Pn 1.6 Ratings. Valves Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge. Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. ( Class Pn 1.6 ) 167 150 Mm Dia 168 200 Mm Dia 169 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 170 Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6Sectional Valves 171 150 Mm Dia 172 200 Mm Dia 173 900 Mm Dia With Gear 174 Providing, Lowering, Aligning, Fixing In Position And Jointing Ms Dismantling Joint Fabricated Steel ( Suitable For Sluice Valves Etc. ) As Per Is Specificationscompleteofthefollowingsizesincludingall Jointing Material, Costofalllabour, Testingandcommissioningand As Per Technical Specifications And Direction Of Engineer In-Charge. Class Pn 1.0 / 1.6 175 900 Mm Dia 176 Construction Of Valve Chamber As Per Approved Drawing And Specification Of Engineer In Charge 177 Type G Size Up To 800Mm To 900 Mm 178 Major Repair Of Pmc Office Building, Residential Buildings At Pmc Campus, All Work Civil, Electric, Water Supply, Road, Drainage Cleaning, Horticulture, Etc. Complete 179 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 180 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 181 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 182 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 183 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 184 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 185 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 186 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 187 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 188 Scraping Old Surface And Redoing Lime Loi Or Sandla. 189 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 190 5.5 Mm Thick Plain Glass Panes. 191 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 192 5.5 Mm Thick Plain Glass Panes. 193 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 194 In Existing Roof. 195 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 196 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 197 Depth 50 Mm To 75 Mm. 198 Depth 75 Mm To 100 Mm. 199 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 200 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 201 4Wide 202 6 Wide 203 Panel By 204 Shuttering Ply - 9Mm Thick ( Commercial ) 205 Wire Gauge 14 Mesh X 24 Gauge 206 Plain Glass Panes 4Mm Thick 207 Aldrop Of Mild Steel 208 12 Long X12mm Dia 209 8 Long X 10Mm Dia 210 Stopper Of Aluminium With 211 Single Rubber Gutka 212 Double Rubber Gutka 213 Door Springs Of Mild Steel 214 Steel Hinges 215 For Wooden Chowkhat 3 Size. 216 For Wooden Chowkhat 4 Size 217 For Stone Chowkhat , 4Size 218 Mild Steel Tower Bolt 6 Long 219 Steel Locking Bolt 220 Steel Handle 6 Size 221 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 222 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 223 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 224 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 225 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 226 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 227 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 228 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 229 Hot Rolled Deformed Bars ( Is : 1139 ) . 230 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 231 20 Mm Thick. 232 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 233 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 234 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 235 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 236 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 237 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 238 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 239 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 240 Sand Or Other Approved Stone 25 Mm Thick. 241 Sand Or Other Approved Stone 35 Mm Thick. 242 Sand Or Other Approved Stone 50 Mm Thick. 243 Kota Stone 25 To 30 Mm Thick. 244 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 245 Jhunjhunu / Jalore ( Red / Choclate Colour ) 246 Above 3601 Cm2 Slabs 247 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 248 Size Of Tile 60X60 Cm 249 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 250 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 251 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 252 Size 100X75mm. 253 Size 125X100mm. 254 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 255 Size 125 X 100Mm. 256 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 257 30 Mm Thick Shutter 258 Commercial Veneer Both Side 259 Decorative Teakveneer One Side 260 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 261 30 Mm Thick Ghana Teak Wood Grade - I 262 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 263 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 264 1:3:6 Or Richer Mix. 265 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 266 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 267 In Cement Mortar. 268 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 269 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 270 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 271 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 272 Ms Sheet 18 Swg 273 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 274 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 275 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 276 14 Mesh X 24 Gauge 277 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 278 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 279 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 280 Providing & Fixing 12 Mm Thick Tegular Edge Glass Fibre Reinforced Gypsum False Ceiling Tiles Of Size 595 X 595 Mm In True Horizontal Level Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanised Steel Sections ( Galvanized @ 170 Gsm / Sqm. ) Consisting Of Main “T” Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38mm Made From 0.30Mm Thick ( Minimum ) Sheet Spaced At 1200Mm Center To Center And Cross “T” Of Size 24X25mm Made Of 0.30Mm Thick ( Minimum ) Sheet, 1200Mm Long Spaced Between Main “T” At 600Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross “T” Of Length 600Mm And Size 24X25mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600mm Panel To Form Grids Of 600X600mm And Wall Angle Of Size 21X21x0.30 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Wherever, Required, Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main “T” Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Fixed To Ceiling With 6 Mm Dia And 50Mm Long Dash Fasteners, 4Mm Gi Adjustable Rods With Galvanised Level Clips Spaced At 1200Mm Center To Center Along Main T, Bottom Exposed Width Of 24Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete At All Heights As Per Specifications Drawings And As Directed By Engineer-In-Charge. 281 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 282 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 283 Old Work ( One Or More Coats ) . 284 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 285 Two Or More Coats On New Work. 286 One Or More Coats On Old Work. 287 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 288 For Area Of Each Slab Up To 900 Sq. Cm 289 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 290 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 291 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 292 Add 10 % For Water Supply And Sainatry Works 293 Add 10 % For Electric Works 294 Horticulture 295 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 296 Girth From 300 Mm To 600 Mm 297 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 298 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 299 From Yard Manure ( Organic ) 300 Compost 301 Goat Dungmanure 302 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 303 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 304 Methly Prathion 2% 305 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 306 Different Flowing Plants 900 Mm To 1500 Mm 307 Different Varrities Of Shrubs 600 Mm To 900 Mm 308 Different Varrities Of Climbers 900 Mm To 1500 Mm 309 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 310 In Rows 7.5 Cms. Apart In Either Direction 311 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 312 Road And Drainage Work 313 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 314 Grading - Ii Material 315 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 316 Crusher Broken -Grade-Ii ( 63-45Mm ) 317 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 318 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 319 With Bitumen Vg-Grade 30 320 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 321 With Bitumen Vg-Grade 30 322 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 323 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 324 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 325 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 326 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 327 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 328 200 Mm Internal Diameter 329 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 330 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 331 Providing And Laying Lean Cement Concrete 1:4:8 In Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg / Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing Complete As Per Clause 601, 112 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion 332 Providing And Laying Un-Reinforced, Plain Cement Concrete Mix With Concrete Mixer & Vibrator Pavement Over A Prepared Sub Base With 43 Grade Cement , Coarse And Fine Aggregate Conforming To Is: 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed As Per Approved Mix Design, Laid, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints Etc Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 333 Pcc M-30 334 Campus Lighting 335 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 336 7 Mtr 337 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 338 Single Arm Overhang 339 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 340 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 341 10.0 Sq.Mm2 Cor 342 Add 5% Over Head 343 Repair Of Pump House Building At Churu, Bhaleri Like Repair Of Plaster, Floor, Roof, Doors, Windows, Colour Washing, Painting Etc. 344 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 345 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 346 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 347 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 348 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 349 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 350 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 351 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 352 Scraping Old Surface And Redoing Lime Loi Or Sandla. 353 Patch Repair To Cement Concrete Floor Including Digging Out Old Floor In Regular Shape And Removal Of Rubbish Curing Etc. Complete In All Respects. 354 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 355 5.5 Mm Thick Plain Glass Panes. 356 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 357 In Existing Roof. 358 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 359 Depth 50 Mm To 75 Mm. 360 Depth 75 Mm To 100 Mm. 361 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 362 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 363 4Wide 364 6 Wide 365 Panel By 366 Shuttering Ply - 9Mm Thick ( Commercial ) 367 Wire Gauge 14 Mesh X 24 Gauge 368 Plain Glass Panes 4Mm Thick 369 Aldrop Of Mild Steel 370 12 Long X12mm Dia 371 8 Long X 10Mm Dia 372 Stopper Of Aluminium With 373 Single Rubber Gutka 374 Double Rubber Gutka 375 Door Springs Of Mild Steel 376 Steel Hinges 377 For Wooden Chowkhat 3 Size. 378 For Wooden Chowkhat 4 Size 379 For Stone Chowkhat , 4Size 380 Mild Steel Tower Bolt 6 Long 381 Steel Locking Bolt 382 Steel Handle 6 Size 383 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 384 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 385 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 386 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 387 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 388 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 389 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 390 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 391 Hot Rolled Deformed Bars ( Is : 1139 ) . 392 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 393 20 Mm Thick. 394 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 395 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 396 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 397 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 398 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 399 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 400 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 401 30 Mm Thick Shutter 402 Commercial Veneer Both Side 403 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 404 30 Mm Thick Ghana Teak Wood Grade - I 405 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 406 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 407 1:3:6 Or Richer Mix. 408 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 409 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 410 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 411 Ms Sheet 18 Swg 412 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 413 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 414 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 415 14 Mesh X 24 Gauge 416 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 417 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 418 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 419 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 420 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 421 Old Work ( One Or More Coats ) . 422 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 423 Two Or More Coats On New Work. 424 One Or More Coats On Old Work. 425 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 426 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 427 75 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 428 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 429 For Area Of Each Slab Up To 900 Sq. Cm 430 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 431 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 432 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 433 Add 5 % For Water Supply And Sainatry Works 434 Add 10 % For Electric Works 435 Horticulture 436 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 437 Girth From 300 Mm To 600 Mm 438 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 439 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 440 From Yard Manure ( Organic ) 441 Compost 442 Goat Dungmanure 443 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 444 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 445 Methly Prathion 2% 446 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 447 Different Flowing Plants 900 Mm To 1500 Mm 448 Different Varrities Of Shrubs 600 Mm To 900 Mm 449 Different Varrities Of Climbers 900 Mm To 1500 Mm 450 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 451 In Rows 7.5 Cms. Apart In Either Direction 452 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 453 Road And Drainage Work 454 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 455 Grading - Ii Material 456 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 457 Crusher Broken -Grade-Ii ( 63-45Mm ) 458 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 459 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 460 With Bitumen Vg-Grade 30 461 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 462 With Bitumen Vg-Grade 30 463 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 464 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 465 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 466 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 467 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 468 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 469 200 Mm Internal Diameter 470 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 471 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 472 Campus Lighting 473 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 474 7 Mtr 475 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 476 Single Arm Overhang 477 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 478 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 479 10.0 Sq.Mm2 Cor 480 Repair Of Residantialbuilding At Churu, Bhaleri, Like Repair Of Plaster, Floor, Roof, Doors, Windows, Color Washing, Painting Etc. 481 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 482 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 483 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 484 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 485 Scraping Old Surface And Redoing Lime Loi Or Sandla. 486 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 487 5.5 Mm Thick Plain Glass Panes. 488 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 489 5.5 Mm Thick Plain Glass Panes. 490 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 491 In Existing Roof. 492 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 493 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 494 Depth 50 Mm To 75 Mm. 495 Depth 75 Mm To 100 Mm. 496 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 497 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 498 4Wide 499 6 Wide 500 Panel By 501 Shuttering Ply - 9Mm Thick ( Commercial ) 502 Wire Gauge 14 Mesh X 24 Gauge 503 Plain Glass Panes 4Mm Thick 504 Aldrop Of Mild Steel 505 12 Long X12mm Dia 506 8 Long X 10Mm Dia 507 Stopper Of Aluminium With 508 Single Rubber Gutka 509 Double Rubber Gutka 510 Door Springs Of Mild Steel 511 Steel Hinges 512 For Wooden Chowkhat 3 Size. 513 For Wooden Chowkhat 4 Size 514 For Stone Chowkhat , 4Size 515 Mild Steel Tower Bolt 6 Long 516 Steel Locking Bolt 517 Steel Handle 6 Size 518 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 519 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 520 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 521 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 522 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 523 20 Mm Thick. 524 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 525 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 526 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 527 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 528 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 529 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 530 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 531 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 532 Kota Stone 25 To 30 Mm Thick. 533 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 534 Jhunjhunu / Jalore ( Red / Choclate Colour ) 535 Above 3601 Cm2 Slabs 536 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 537 Size Of Tile 60X60 Cm 538 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 539 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 540 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 541 Size 100X75mm. 542 Size 125X100mm. 543 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 544 Size 125 X 100Mm. 545 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 546 30 Mm Thick Shutter 547 Commercial Veneer Both Side 548 Decorative Teakveneer One Side 549 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 550 30 Mm Thick Ghana Teak Wood Grade - I 551 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 552 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 553 1:3:6 Or Richer Mix. 554 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 555 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 556 In Cement Mortar. 557 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 558 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 559 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 560 Ms Sheet 18 Swg 561 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 562 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 563 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 564 14 Mesh X 24 Gauge 565 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 566 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 567 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 568 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 569 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 570 Old Work ( One Or More Coats ) . 571 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 572 Two Or More Coats On New Work. 573 One Or More Coats On Old Work. 574 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 575 For Area Of Each Slab Up To 900 Sq. Cm 576 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 577 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 578 Add 10 % For Water Supply And Sainatry Works 579 Add 10 % For Electric Works 580 Repair Of Boundry Wall At Pmc, Bhaleri, Including Provinf Fixing Of Borbed Wire Fancing Repair Of Gates Et. 581 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 582 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 583 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 584 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 585 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 586 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 587 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 588 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 589 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 590 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 591 Columns, Pillars, Posts And Struts Etc. 592 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 593 Hot Rolled Deformed Bars ( Is : 1139 ) . 594 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 595 20 Mm Thick. 596 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 597 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 598 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 599 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 600 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 601 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 602 Old Work ( One Or More Coats ) . 603 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 604 Two Or More Coats On New Work. 605 One Or More Coats On Old Work. 606 Part : E Electrical Works 607 33 Kvring Main Unit Consisting Of 2 Lbs At Incoming & 2 VcbSoutgoing As Per Requirements And Specifications. 608 Stranded Compact Circular Aluminium Conductor, Conductor Screened With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screened With Copper Tape, Cores Laid Up, Inner Sheath Of Pe Type, Galvanised Steel Flat Strip Armoured And Overall Pvc Sheathed Cable Confirming To Is 7098 / Ii / 85 With Latest Amendments Of 33 Kv ( Ue ) 609 3Cx300 Mm2 610 Providing & Making Heat Shrinkable Type Indoor / Outdoor / Straight Through Terminations / Joint Kit Of Approved Make Suitable For Xlpe Insulated 33 Kv Cable, With Required Components, Prepration Of Cable Ends, Testing Etc. 611 3 Core 240 / 300 / 400 Sq.Mm 612 Outdoor 613 Indoor 614 Sitc Of Floor Mounted Pmcc ( Indoor, Dust Proff Ip-4X Front Operated With 2 Mm Thick Sheet Metal Compartmentalised ) With All Accessible Parts, Head Shrinkable Sleeves, Smc / Dmc Bus Bar Supports, Padlocking Facility On Outgoing Feeders Etc. 615 Lv Capacitor With Apfc Panel 616 Sitc Of Microprocessor Based Intelligent Power Factor Correction Relay Having Sensitivity Up To 50 Milli Amp Secondary Current And Following Way, Self Analysing Auto C / K Setting According To Targeted Power Factor Setting, The Relay Shall Have Minimum Three Digit Display Unit For Display Of Real Power Factor, Targeted Power Factor, Lag / Lead Capacitor Switching Status, Alarm Output For Under Current, Over Current, Insufficient Compensation, Indication Of Switching On Units, Auto / Manual Status, And 6 To 14 Stage - Sensitivity Upto 50 Milli Amp. 617 Sitc Of Self Healing Mpp / Mp Type Shunt Capacitor ( Banks ) Conforming To Is:13340-41 / Iec :831-1&2 In Existing Panel Or Parallel With Load Terminals , The Capacitor Shall Be Fitted With Discharge Resistors, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50 Hz And Total Wattage Loss Less Than 0.5 Watt Per Kvar. Including Making Connections With Suitable Capacity Conductors / Cables Testing As Required.Heavy Duty Three Phase 440 V , 50 Hz Capacitor ( Bank ) 618 P / Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Iind Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. 619 3 / Cx6 Sq Mm 620 3 / Cx10 Sq Mm 621 3 / Cx16 Sq Mm 622 3 / Cx25 Sq Mm 623 3 / Cx240 Sq Mm 624 Supplying And Making One End Termination With Heavy Duty Double Compression Brass Gland Sibg Type, Aluminium Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. 625 3 / Cx6 Sq Mm 626 3 / Cx10 Sq Mm 627 3 / Cx16 Sq Mm 628 3 / Cx25 Sq Mm 629 3 / Cx240 Sq Mm 630 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Covering 631 3C X 2.5 Sq.Mm 632 5Cx1.5 Sq Mm 633 14Cx1.5 Sq Mm 634 Supply & Makingone End Termination With Heavy Duty Single Compression Brass Gland Sibg Type, Copper Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Arrmoud Pvc Insulated And Pvc Sheated / Xlpe Almunium Cunductor Cable Of 1100 Volt Grad As Required Size. 635 3C X 2.5 Sq.Mm 636 5C X 2.5 Sq.Mm 637 14 C X 2.5 Sq.Mm 638 Supply, Fabricating & Installing Following Sizes Of Perforated Cable Trays Including Horizontal And Vertical Bends, Reducers Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Suspenders And Including Painting As Required. 639 600Mm X 50Mm X 2.0Mm 640 150Mm X 50Mm X 1.6Mm 641 Supply, Installation, Testing And Commissioning Of Copper Wound Transformers 33 / 0.433 Kv, Three Phase, 50 Hz, Dyn 11, Onan Type , Standard Accessories With Off Load Tap Changer ( +5% To -10% In Steps Of 2.5% ) , Winding / Top --- Temperature Rise Of 45°C / 40°Cfirst Fill Oil, Having Permissible Total Loss Values Not Exceeding 7.5% Of The Maximum Total Loss Values For 11 Kv As Per Energy Efficiency Level - 2 At Basic Insulation Level Conferming To Iss 2026 ( Part- I To Part - Ii ) , Latest Ammended And Is 1180 Part-I : 2014. Transformers Described As Above And As Per The Following Continuous Rating 642 400 Kva 643 1250 Kva 644 1600 Kva 645 S.I.T.C. Of Bus Duct Arrangement In Convenient Sections Complete With Enclouser Of Crca Sheet Steel Of Minimum 2 Mm Thickness, Aluminium Bus Bar And Earth Bus For Use On 3 Phase, 4 Wire, 415 Volts, A.C. Supply With Degree Of Protection Ip-42 For The Following Current Carrying Capacity, Including Jointing Of Sections, Copper Flexible Joints. Expansion Joints, Bends, And Earthing With 2 Runs Of Alum. Strips Etc. As Required 646 1 Straight Run With 2 Earth Bus 3200 Amp 647 Bend 3200 Amp 648 Copper Flexible Tpn 3200 Amp 649 Supply Installation Testing & Commissioning Of Local Push Button Stations 650 Maintenance Free Gel Earthing With Pipe In Pipe / Strip In Pipe Technology Filled With Anti Corrosive Conductive Compound ( Cpri Tested ) Below The Ground In 150 -200 Mm Dia Earth Pit And Surrounding Filled With Required Mineral Filling Compound ( Mfc Should Have Hygroscopic Proper Ty To Retain The Moisture For Long Time To Create Low Resistance Zone ) And C.C. Finished Chamber Covered With Hinge Type With Locking Arrangement C.I Cover. C.I. Frame Of Size 300Mm X300mm Complete Testing Of Earth Resistance As Required Of Following Sizes With Pipe In Pipe Technology ( Inner Pipe Dia / Outer Pipe Dia ) 80 -100 Micron G.I. Coating Of The Size G.I. Pipe 3000 Mm Long , 80 / 40 Mm , Terminal 14 Mm G.I. Strip 651 S & Laying Following Size Earth Wire / Strip In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection Etc. As Required. 652 50Mm X 6Mm G.I. Strip 653 25Mm X 6Mm G.I. Strip 654 25Mm X 3Mm G.I. Strip 655 10 Swg G.I. Wire 656 P & F Lightning Conductor Final Made Out Of 25 Mm Dia., 300 Mm Long Copper Tube Having Single Prong At Top With 85 Mm Dia., 3 Mm Thick Copper Base Plate Including Holes Etc. Complete As Required. 657 Part : F Instrumentation & Scada 658 Sitc Of Ultrasonic Level Transmitter Suitable For Measuring Water Level In Reservoir, Normal Powered 24Vdc, Type Of Transmitter: Two Wire ( 4-20 Ma ) , Cable Entry:1 / 2 Npt ( F ) , Sensor Material: Pp, Slip-On Flange: 2 ½” Flange, Material Of Construction For Slip-On Flange: Pp, Output 4~20Ma, Hart Compatible, Accuracy + / _ 0.2 % As Per Detailed Technical Specification, Scope Of Work And Direction Of Engineer In Charge. Measuring Range 0.0 To 6.0 Mtr 659 Providing, Installation, Testing And Commissioning Of Diaphragm Type Pressure Gauges Dial Size 150 Mm Glycerin Filled Shatterproof Glass, Over Range Protection: 125% Of Maximum Pressure, Material Of Sensor And Other Wetted Parts: Ss Type 316, Housing Material: Die Cast Aluminum 660 Providing, Installation, Testing And Commissioning Of Pressure Transmitter For Water Application: Range: 0-10 Bar / Power Supply: 24 V Dc / Output: 4-20 Ma With Hart / Diaphragm: Ss316l / Process Connection: 1 / 2 Npt ( M ) / Accuracy: 0.15% Protection: Ip671 / 2 M ( Npt ) 661 Sitc Of D / F Full Bore Type Electromagnetic Flow Meter Of Approved Make Of Following Dia And Specifications Complete: Media : Water ( Raw / Chlorinated ) , Pressure : Up To 1.5Mpa, Process Temp: - 50 Deg C, Flow / Meter Tube : Ss 304, Electrode : Ss Aisi 316L / Hastelloy C276 / Tantalum, Lining Material : Hard Rubber / Neoprene / Poly-Urethane ( Pu ) , Flange : Ss / Cs, Flange Standard & Rating : Ansi 150, Coil Housing : Ss Aisi 304 / Carbon Steel / Die Cast Aluminium, With Anticorrosive Paint & Provide Completely Sealed ( Leak Proof ) Construction As Per Requirement Of Iec 60529, Accuracy : ± 0.5 % M.V.- Velocity 0.3 To 10 M / S, Transmitter / Signal Convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V Ac - 50Hz, Output 1 : 4-20 Ma, Output 2: Pulse, Communication Output : Rs 485 / Heart, Display Type : Lcd / Led Display, Cable Entry : M20 X 1.5, Provision Of Ram / Prom To Store Calibration And Configuration Parametersand Totalizer Value During Power Failure, Protection Category- Ip 68 For Sensor ( Flow Tube ) And Ip 67 For Transmitter / Convertor, Including Surge Arrester, If Required, And All Materials Required For Making Connection With Existing Pipeline Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 662 150 Mm Dia 663 200 Mm Dia 664 250 Mm Dia 665 400 Mm Dia 666 900 Mm Dia 667 Sitc Of Bulk Flow Meter With Removable Mechanism Class B Confirming To Iso:4064:2005 / Is: 2373Of Approved Make Of Following Dia Sized Pipelines And Specifications Complete:Media : Water ( Clear ) , Temp. 50 Deg., Pr. Rating: Pn16, Protection Type: Ip- 68, Body Material : Is-210 Gr. Fg-200, Accuracy Class :Class B ( ±2 % @ Nominal Flow Rate ) , Magnetic Drive, Dry Dial, Epoxy Powder Coated, Pulse Out Put Option, Anti-Magnetic Protection Including All Materials And Making Connection With Existing Pipeline Required For Bulk Flow Meter Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 668 Bfm 100 Mm 669 Bfm 150 Mm 670 Bfm 250 Mm 671 Sitc Of Rtu Complete With Di, Do, Ai And Modbus Communication Ports And Power Supply ( 24 V, Dc ) 672 Providing And Laying Stranded / Flexible Annealed Bare Copper Conductor , Xlpe / Pvc Insulated 2 Pair 1.5 Sqmm Suitably Laid Up Together Overall Polyester Taped Al ( Mylar Tape Wrapped ) Along With Atc Drain Wire Overall Pvc Sheathed ( St-1 ) Overall Screened Triad Armoured Instrumentation Cables Generally Confirming To Pas 5308- Part-2-2009 673 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Coveringsize 3C X 2.5 Sq.Mm 674 Supply, Installation, Testing And Commissioning Of Mnre Approved Off Grid Solar Panels For Running Of Motor Pumps With 25 Years Of Linear Generation Warranty, Work Includes Designing Of Solar Panel Area And Ms Frame And Foundation On Ground / Roof Of Pump House Or Cwr, Showing Arrangement Of Panel In Available Space, Installation Of Pv Module On Ms Frame As Per Approved Design And Drawings. Mounting Structure Shall Be Suitably Design To Withstand Wind Velocity Up To 150Km / Hr. The Work Shall Be Executed As Per Detailed Technical Specifications, Approved Drawing And Direction Of Engineer In Charge. Note: There Shallbe5 Year Service Warranty For Solar Panel And Mounting Structure Andsuitable Provision Shall Be Included In Tender Document ( Each Of .5 Kw ) 675 P&F Of Gsm / Gprs Based Data Transmitter Device Forwater Meter Compitable To Scada System. 676 Supply, Installation, Testing, Commissioning Of Plc / Scadasystem Including All Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations. 677 Cps Bhalari 678 Supply, Installation, Testing, Commissioning Of Master Control Room Including All Plc / Scadasystem, Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations.Churu 679 Part G : Operation & Maintainance & 680 Cost Of Operation And Maintenance Of The System For 10 Years After Defect Liability Period Of One Year @ 6.0%On Above Items Excluding Villages Inrta Systemand As Per Scope Of Work & Specification 681 Operation And Maintenance Charges 1St Year 682 Operation And Maintenance Charges 2Nd Year 683 Operation And Maintenance Charges 3Rd Year 684 Operation And Maintenance Charges 4Th Year 685 Operation And Maintenance Charges 5Th Year 686 Operation And Maintenance Charges 6Th Year 687 Operation And Maintenance Charges 7Th Year 688 Operation And Maintenance Charges 8Th Year 689 Operation And Maintenance Charges 9Th Year 690 Operation And Maintenance Charges 10 Th Year 691 Part H : Dismantling Of Old Pump Sets 692 Cost For Dismantling Of Old Pump Sets, Electrical Panels And Intrumentation Etc And Depositing In Depatmental Stores As Per Direction Of E.I.C. 693 Tps Karamsana 694 Ir-4 695 Cps / Tps Bhaleri 696 Cps / Tps Churu
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
49.
Housing Urban and Rular Development #10235078 Price Bid
Tender For New Construction Of Cheriyan Nagar Library Chennai; 1 DISMANTALING WORKS 2 Dismantling etc., all complete 3 Brick / Stone Masonry in lime mortar walls 4 Dismantling RCC by manual / by using deploying machineries 5 Doors and Windows including removal of frames, hinges and fastenings 6 CIVIL WORK 7 Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size bouldersand Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete SS.20B 10 cum 8 Carting away surplus excavated earth available with in the campus is to be carted to a lead of within 40 KM from site. The rate shall include loading into the tipper/ lorry transporting and unloading, leveling and the earth scooped by bulldozers grading etc.,complete with all respects complying with relevant standard specification, as directed by the Departmental Officers. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 9 Supplying and filling in foundation andbasement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. 10 Supplying and filling in foundation, basement, etc with filling Gravel inwellrammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 12 Providing pre-constructional Antitermite treatment including cost of chemicals labour as per standard specifications for preparing the area for treatment by spraying chemicals and other incidental charges etc.. complete. The rates should be for antitermite treatment from the plinth beam and brick masonry with super structure in contact with the back fill earth and at the junction of the walls.The top surface of filled earth for flooring and the soil along with the perimeter of the building by making holes with the crow bar and poured 5% termicide “Chloripyrifos” and sprayingthe same termicide solution on the wooden frames and treating the other periphery of buildings etc., complete in all respects as per IS 6313 (part II) / 1981 and as directed by the departmental officers. 13 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc.,Rate to include all materials, labour charges, wastages ,placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by theClient / Engineer-in-charge. 14 For Column footing, plinth / grade beam, bed blocks, template surfaces, steps, piers, raft slab / beams and such other members 15 for plane surfaces such as rectangular or square rcc columns, sunshades, topand bottom slab of rcc boxing, etc. 16 Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members 17 Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Raft, Grade beam, Shear wall, RCC walls, Lift walls, Plinth beams, Column, footings, Grade slab, Roof slab & beam, Curved slab, beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box binders basement retaining wall, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. 18 For FoundationandBasement 19 For Ground Floor 20 For First Floor 21 For Second Floor 22 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required.Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 23 Supply and constructing Fly ash Brick (230 x 110 x 75mm) masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure usingFly ash Bricks of size 230x110x75mm etc. Rate to include all materials, labour charges, wastagesfor working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 24 For Ground Floor 25 For First Floor 26 For Second Floor 27 Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height + 0.5 M Projection + 0.5 M into the Ground) the distance between the two rows being 1.25 M and the spacing of posts being 2.0 M in both the rows with two horizontal posts with 0.5 M. Overlap on either side and braces at 2.0 M Center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40 mm thick and 1 M width, etc. in a complete from using coil and nails. 28 Upto 3 M Height 29 3 m to 5.5 m Height 30 5.5 m to 7.5 m Height 31 7.5 m to 10 m Height 32 10 m to 12.5 m Height 33 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of P sand) according to the specification. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 34 Plastering 15 mm thick for external surfaces with Cement Mortar 1:5 (1 of cement : 5 of P sand) with water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed. The rate includingcost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 35 Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of fine river sand)according to specifications. Rate shall include for providing GI chicken mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 36 Painting the new plastered walls with two coats for Interior Plastic Emulsion paint approved quality and colour over a priming coat, with two coats of wall putty including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 37 Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 38 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work 39 UPVC VentilatorSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chamberedsections with wall thick of2mm.The EPDM rubber (black colour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The ventilator should be got approved from the Executive Engineer before use on work 40 Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. 41 Painting the new Iron work with two coats of Ready Mixed Enamel Paint of aproved quality and colour over the existing priming coatincluding the cost all materials etc.,complete, in all floors and as directed by the Departmntal Officers. 42 Providing and fixing Vertical blinds , quality of approved make fabric made of 100% polyester woven fabric thickness 0.40mm with virtually maintenance free having plastic bottom chain thickness of chain-0.50mm and diameter-3mm, Plastic with metal bottom and suitable coating on exterior, including all fixtures and fittings complete in all respect as per design/color/shade including requisite installation brackets etc as required for installation at site with anchoring arrangements complete. 43 Supply and laying with best quality the following materials of Ruby Red, Raw Silk Granite Slabs (Super Fine Polished with Machine Cut Edges) of sizes 4’x2’ and above 18mm to 20mm thick Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 44 Supply and laying with best quality the following materials of Sinthetic Grey, Paradise and similar varieties Granite Slabs Granite Tiles - (Superfine Polished with Machine Cut Edges) of size 2’0” x 1’0” and above 10mm Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 45 Nosing for Granite Slab-Single Nosing 46 Grooving the Granite Slab 47 Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Executive Engineer before use on work 48 Paving the floor with design Antiskirt Ceramic tiles (colour and shade as directed) of size 305 mm x 305 mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement. 49 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 50 Supplying and filling the sunken slab area by BRICK-BATCOBA by adding CICO NO:1 of approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Naterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc Rate including all mater aaod and lifts, working materials, labour charges wastages with necessary lead and at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specificatior and as directed by the Client/ Engineer-in Charge 51 Including applying two coats not less than 2 nm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No. 1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 52 Waterproofing: Providing and Applying CFTRI approvedtwo component flexible polymer modified acryliccementitious waterproofing coating with a mix ratio of(5 Liquid :7 Powder) to the RCC surface of the UGT/OHT tankapplied @ 2.2kg/m2 in 2 coats to achieve1.2mm DFT, having Elongation at break >120% asper ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right anglesof wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completelyas per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applyingtwo component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification 53 Finishing the top of roof with one course of Solar Reflective ceramic tiles of size 305 mm x 305 mm x 7 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 54 Supplying And Fixing Rubber Moulded Interlocking Paver Blocks Against Available Edge Restraints 83 mm Thick of Approved Design And Pattern of Strength 40 N/Sq.m. 10 mm Iss Metal With Minimum Cement Content As Applicable To M 40 Grade Concrete As Per Is-456-2000 Manufactures By Mechanical Or Hydraulic Machine Using Vibro- Compaction Process And Laid Over 50 mm Thick Laying Course (Bedding) Crushed Stone Sand (M Sand) Well Compacted By Plate Compactor With A Joint Width of 2 mm To 5 mm Including Filling of All Joints With Crushed Stone Sand (M Sand) And Compacting The Paved Surface With Plate Compactor Two Or Three Times Until All The Unit-To- Unit Joints Are Completely Filled With Crushed Stone Sand (M Sand) And Trimming The Edges Neatly Including All Labour Charges And Plate Compactor Charges Etc. Complete(Cost Inclusive of Crushed Stone Sand (M Sand)) 55 Supplying and fabricating of MS structural steel supports for various applications using channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete. Supports shall be powder coated with required colour for different system as mentioned above. 56 Providing Teak wood wrought and put up for frames of doors, windows and ventilators and any other similar joinery works including cost of country wood scantlings and labour charges for manufacturing the frames and fixing hold fasts and fixing in position etc. for all lengths as per architect designs. 57 Best Indian Teak Wood Panelled door in double shutters with frames 100x75mm at side,verticals and top. The shutters shall beof 40mm thick with moulded panels in 20mm thick planks,6Nos.of iron hold fasts fixed in c.c.1:2:4 6Nos.of butt hinges 125mm long including wind appliances, furniture,iron fittings,1No.of iron padlock 15cm long for locking arrangements and fixing inposition,etc.,complete.(ISI STD) 58 Varnishing the new wood work one coat with best shellac and with fine best varnish of approved quality varnish of teak wood natural finish including preparation of surfaces with sand papering in patty priming etc., complete complying with standard specification and as directed by the Departmental officers. 59 Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter 60 Best Indian Teak Wood panelled door shutter for single leaf door. The shutter shall be 40mm thick with moulded panels in 20mm thick planks inclusive of 3 Nos.butt hinges 125mm long,furniture iron fittings,1No.of jappened hooks and eyes 200mm long and 6mm thick and iron pad lock 15cm long including fixing inposition,etc.,complete 61 FALSE CEILING WITH GYPSUM PLAIN TILES Providing and fixing true horizontal level false ceiling using SAINT -GOBAINGYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at1200mm c/cmax by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm (Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying 62 Art work as per the direction of department official, over Oil Painting with first class quality and approved colour including a priming coat with thorough scrapping clean removal of dirt., etc., complete and including necessary plaster of paris, putty, etc., wherever required (Relevent ISI STD), including putty works. 63 Supplying and Fixing of English Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 64 Supplying and Fixing of Tamil Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 65 upplying and Fixing ofEmblem (15”) Stainless Steel size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 66 Supply and fixing of Pre-fabricated Structural Steel, coated galvalume ROOFING SHEET of 0.5mm thickness with SMP coating with colour bond XRW coating, having minimum of 550 Mpa yield strength, Coating 150 GSM as per ASTM 792 or equivalent standard. The structural roofing Panel shall have 1020 mm effective width, nominal 30 mm crest height at nominal 250 mm centre to centre pitch with the embossment (share grove) on top & side of ribs for better composite action including Flashing for joints, and all incidental charges. 67 Supplying and erecting in position LIGHT DUTYSTEEL TRUSSES as per the drawing.The materials and design of the trusses should confirm to the relevant Indian Standard specification.The trusses shall be procured only from reputed manufactures oftrusses with prior approval of the Buildings Engineer and a certificate to the effect from the reputed manufacturers shall also be furnished with design.The rate quoted shall include the cost oftrusses.Base-plate with holding down bolts and nuts to RCC or Masonry works, roof purlins, rafters, purlin sleeves, the members fixing accessories etc., painting one coat of red-oxide paint and erecting in position etc., complete as directed during execution. The contractor shall also arrange to provide grouting for holding down bolts embeding the end purlins, to the gable wall wherever necessary etc.,The roof sheeting shall project 0.762m from the eves purlins. 68 Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevical and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete. 69 Providing, supplying, and fixing factory-manufactured pre-fabricated insulated roofing panels made of PUF (Polyurethane Foam) sandwiched between two metal skins, comprising pre-painted galvanized iron (PPGI) sheets of 0.5 mm thickness on both sides with 40 mm to 50 mm thick CFC-free polyurethane foam core of minimum density 40 kg/m³, having tongue and groove jointing with cam-locking arrangement for weather-tight sealing. Panels shall have minimum overall R-value of 6.5 and thermal conductivity not more than 0.022 W/m·K. Roofing to be supported over structural purlins/trusses using self-drilling screws with EPDM washers, sealants, fasteners, ridge covers, and flashing, complete. Rate includes supply, transport, hoisting, cutting to size, edge finishing, foam taping at joints, sealing, labour, tools, scaffolding, and all incidentals for a fully finished, insulated, and weatherproof roofing system as per manufacturer’s specification and as directed by the Engineer-in-Charge. 70 Brick Wall Cladding Nuvocotto Edge Cut Wall Tiles Natural Red finish in size 230mm x 76mm x 15mm 71 Brick JalliNuvocotto Camp Jallie Natural Red finish in size 200mm x 200mm x 60mm 72 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT 73 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 74 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 75 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 76 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 77 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 78 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 79 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,. 80 PLUMBING 81 Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, unioncoupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting. 82 Supplying and fixing Stainless Steel Health Faucetwith all the accessories etc, 83 Supply and fixing White without PedastalWash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia B Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples,15mm CP Pillar Tap etc (The wash basin should be got approved by Executive Engineer before use on works). 84 Providing and fixing C.P. Angle stop cock of approved quality conformingto IS:8931 :15mm nominal bore 85 Providing and fixing Brass Chromium Plated Towel Rail 60cm long and20mm dia with Brackets etc,. 86 Providing and fixing Brass Chromium Plated Soap Tray of size 150mm x 100mm 87 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines. 88 75 DIA 89 110 DIA 90 Providing, fixing and testing of PVC waste pipe of agricultural sereis conforming to IS 4985 including all fittings like tees, elbows, bends, collars, coupling, etc jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete as applicable, curing etc., complete. 91 40 DIA 92 Providing, fixing and testing of PVC floor- trap 110 dia with necessory of multitrap connection (heavy duty hinged type) with brass CP frame & cover (100 mm x 75 mm). Trap of 100 mm dia inlet and 75 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects) 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Concealed On Wall) 94 20MM DIA 95 25MM DIA 96 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : 97 25mm dia Cost of gate valve 98 32mm dia Cost of gate valve 99 Providing, installation, testing and commissioning approved make CIY-type Strainer conforming to IS standardwithnecessary companion flanges, neoprene gaskets(10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories to complete the work as per the specifications. 100 32 mm nominal bore 101 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines.(Pipes Runningin the Shaft & below ground level) 102 75 DIA 103 110 DIA 104 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Pipes Runningin the Shaft & below ground level) 105 25MM DIA 106 32MM DIA 107 Providinging and fixing in position PVC Vent cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 108 75MM DIA 109 110MM DIA 110 Providing and fixing GI. puddle flanges (IS; 1239) fabricated out of 6 mmthick M.S. plate of size 300 x 300mm plusdia of pipe of 750mm long pipe pieces fixed to RCC wall of water tanks. Including painting with two coats of primer complete as required. The entire fitting shall be hot dipped galvanized.(Rate As per Quotation) 111 32 mm dia 112 40 mm dia 113 50 mm dia 114 65 mm dia 115 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:(Rate As per Quotation) 116 Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 230 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC precast cover (SFRC), benching in CC M-15, internalfaces plastered smooth in CM1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 600x600 mm size internal and depth will 450mm to 1200mm & 900x800 mm size internal and depth will 450mm to 1200mm. (Rate As per Quotation) 117 600x600 118 Making of core cutting in RC slab of maximum 150mm thick of following diameter. 119 a) 150 mm dia 120 b) 125 mm dia 121 Providing and fixing MS slotted angle iron brackets, hangers, MS grip bilts,universal clamps with thereaded rod,supports with necessary drilling holes to suit the insertion of pipe clamps, deburring etc., as per detailed drawing for supporting soil, waste and rain water pipes and water Providing pipes in shafts with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls/outer walls etc., The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08 mm thick conformed to IS 1239 etc., complete as directed by the employer. 122 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.(600x600mm) 123 Providinging, installing, fixing, jointing, testing and commissioning of PVC Storm water pipe confirming to IS 13592 of SWR quality 4 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste,The quoted rate shall include necessary earth work, fittings,pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting,refilling, and making good the same complete as required. 124 110 DIA 125 Providing, fixing and testing of Terrace Rain water outlet (110dia) with all the accessories etc,. 126 INTERIOR 127 BOOK SHELF 1 - 2100 x 400 x 2100 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 128 MAGAZINE HOLDER - 600 x 250 x 1200 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 129 DISPLAY UNIT AT RECEPTION - 1200 x 300 x 600 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 130 LEDGE 5000 x600 x 750 Panels are 16mm MR ply with 1mm Matt Finish on both sides with 2mm PVC Edge Band finish mounted to the wall. 131 4SEATERLEARNINGCENTRETABLE-2000mmx1000mmx750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thick 132 6SEATERLEARNINGCENTRETABLE-2400mmx1000mmx 750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thic 133 READING CHAIR - Lounge Chair Uphostered in EPU Leather. Sleek Four Star Fixed Base With Revolving Function In Warm White Powder Coated Finish. Three Dimensional Lumbar Support Design. Model number SCML-SF30.1. Bosses Cabin or equivalent. 134 ROLLINGCHAIRS-Medium back chair with metal grey back frame, metal grey adjustable PU armrest (4D), moulded foam seat with metal grey shell, STG drive-by-wire mechanism with 4 position locking, polished aluminum alloy five-star base with metal grey PU castors. Model number CHT66SW. Bosses Cabin or equivalent. 135 SINGLESTUDYCHAIR:Multi-Purpose Chair Upholstered In Water Based PU Leather. Cushioned Seat and White Ash Solid Wood Legs. Model number SCMF-XCB33 - Latte Brown. Bosses Cabin or equivalent. 136 LOCKER & FOOTWEAR STORAGE- – 1950x375x470mmPLU main 2 DR numeric lock with envelop slot – 1950x375x470mm. Godrej interio or equivalent. 137 RECEPTIONDESK-1800mmx650mmx 1050mm- Reception Table In Matt White and Oak Laminate. IncludesStorage Cabinet and WireManagement Grommet OnDesk. Top Model number 28ROB003(BCRMB-OB 03). Bosses cabin or equivalent. 138 Seamlessly shift from warm, cozy tones to cool, vibrant whites (also known as tunable white or human-centric lighting) is an advanced JS3 Serial LED Connecting System LED lighting technology that allows users to adjust the color temperature of the light output — from warm to cool — to suit mood, time of day, or functional needs.LED Type: OSRAM SMD 3030Iceil™ Supply of OSRAM 24V LED Module Color Temperature: 2700K to 10000K with Iceil IP67 Drivers CRI: ≥90 – Delivers natural, true-to-life color accuracyMounting: High-performance aluminum rigid PCB– Ensures excellent thermal management and long lifespanConfiguration:– Each block features 4 high-quality LEDs– Optimized light spacing for shadow-free illumination– Viewing Angle: PMMA lens Ultra-wide 160° beam spreadDimmable: No Compatibility:DALI, Tuya Smart App, Alexa, & Google Home. Touch Panel, and RF Remote control optionsPower Consumption:– Only 4-6W per sq.ft– Energy-efficient yet high-lumen outputLighting Quality:– Uniform light diffusion across the stretch ceiling– Suitable for both translucent and printed membrane typesIceil™ Power Supply: Wide Input Range 100-305AC (Class I), Surge Protection with 6KV/4KV, Working temp. -20~ +45°C 20% ~ 90%RH, Metal case IP67, Power factor <0.98LED and Power Supply Warranty: 5 Years or 50,000 Hours (whichever comes first)Certifications: CE & RoHS Certified – environmentally safe and globally compliant Installation of pre-supplied LED lighting fixtures, associated drivers, and control systems, including all necessary mounting, wiring, terminations, and system integration by qualified technicians.The scope includes:Installation of LEDs as per lighting layoutMounting and secure placement of LED drivers and control gear in accessible locationsElectrical connections between LEDs, drivers, and controllers using appropriate cablingTesting of each circuit and commissioning of the full lighting setupRate Includes: Skilled labor, tools, basic fasteners, and all on-site installation efforts.. 139 Iceil™ supplies exclusively premium-grade of European Standard PVC Thermo-Stretchable Membrane, complying with BS1-D0 as per EN 13501-1 and Class A as per ASTM E84-2024 fire safety standards. The membrane is precision-cut to the required shape and size, with perimeter edges high-frequency welded with harpoon inserts. Installation is carried out using a durable aluminium profile framing system, ensuring a seamless, secure, and aesthetic ceiling solutionThickness 0.18 mmWeight 250–300 gsm ± 2%Light Transmission Up to 75% (for translucent type)Width Up to 5 meters (seamless); larger areas joined with invisible seamsStretching Method Thermal installation at ~50–60°C using hot air gas blower Fire Rating BS1-D0, as per EN 13501-1, ASTM E84-2024 Class A Explanation: B = Very limited contribution to fire, s1 = Little or No Smoke Production, d0 = No flaming droplets or particles Moisture Resistance 100% Moisture-proofUV Resistance Yes – does not yellow or degrade indoorsEnvironmental ROHS compliant, Phthalate-free, UL Certified - Tri-O-cresyl phosphate < 50mg per kgCertification Manufactured in ISO 9001:2015 certified factoryWarranty 10 Years (under standard indoor conditions) Installation of pre-supplied Stretch Ceiling System, including site preparation, profile fixing, membrane stretching, and finishing using specialized tools and skilled labor.The scope includesFixing of aluminum/PVC perimeter profiles as per approved ceiling layoutHeating and stretching of the pre-cut stretch ceiling membrane on-siteAlignment, tensioning, and seamless fitting of membrane onto the installed profilesIntegration of cutouts for lighting, sprinklers, air conditioning vents, speakers, etc.Final finishing, cleaning, and handover of installed ceiling areaRate Includes: Skilled labor, installation tools, on-site execution, and necessary accessories for completing the installation of the stretch ceiling. 140 The Iceil Wooden Box is built from durable MR/BWP-grade plywood, featuring a 12mm back board, 18mm vertical sides (150mm height), and dual 8mm flexible plywood layers for curved designs. The 150mm depth accommodates lighting and structural needs.Finish Options: White emulsion or PU-coated interior, or white reflective laminate; exterior customizable per client.Mounting: Reinforced corners, cross supports (wood/MS) every 2 ft, fixed with dash fasteners, threaded rods, or MS supports.Stretch Ceiling Compatibility: Suits Iceil’s PVC Harpoon Profile System with aluminium profiles for welded membranes.Lighting Integration: Base for rigid block LEDs with ventilation slots for heat dissipation. 141 Wall paper 142 Carpet Flooring 143 160A LT Metering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, Wall mounted, single front,14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., including all associated control wiring. The Breakerof 160A TPN MCCB and 1set of 160/5A CT with TNEB Metering provision and 1nos of 160/5A CT for APFCR . (Rate as per Quotation) 144 Supply and Erection of electrical panels Boards 145 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type Three Phase Changer Over panel of size (H 2100 X L 2000 X D 300 ) mm with suitable to accommodate 100A 4 pole Three phase Change Over Switch-1No. as incomer for EB Source and as incomer for DG Source, 6nos of 63A 4Pole MCCBs and 4nos of 32A 4Pole MCCBs compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 146 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type 50 kVAR panel of size (H 1800 X L 1800 X D 300 ) mm with suitable to accommodate Incomer 1 Nos 63A 4Pole MCCB, 7nos of 25A 4Pole MCCBs with 7% 1-10 kVAR Capacitor banks in compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 147 VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB : Supply and fixingof4way verticalTPMCBsheetsteel Industrial Type TP MCB DB with IP54 Protection of surface type fitted with bus bars and neutral links with1 No. of 63A FP MCB as Incoming and 4 Nos.of32A,10KA Triple Pole MCB in Flush with wall and making good of the concealed portion with earth connection.( Industrial Type TPMCB DB with IP54 Protections) 148 Supply and fixing of 7 segment8 way63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 63 A TPN MCB, 10kA, / Isolator and another separate 4 way for accommodating one no. 63 Amps, 30 mA, 4 pole ELCB / RCD (totally 8 ways in one segment) and 24 nos 6-32 A, 10kA, SP MCB / Isolators ( totally 24 nos.) for outgoing in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only. 149 Supply and fixing of 65 mm dia. (2 -1/2) GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonry pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 90W LED Streetlight fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour 150 Supply and Fixing of24W Ceiling Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 151 Supply and Fixing of11W Bulk Head Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 152 Supply of surface-mounted 24W LED wall lights to the ideal solution for a variety of indoor lighting applications. Direct illumination of the wall and surrounding surface, as well as accent lighting for vertical structures. Featuring an aesthetically pleasing, robust construction, these lights are built to withstand all weather conditions, ensuring long-lasting performance and durability • Luminaire body made of extruded aluminium alloy (grade 6063) with die cast aluminium components and non corrosive SS fasteners • Non yellowing UV stabilized translucent polycarbonate diffuser • Luminaire integrated with 24W LED • Die-cast aluminium mounting base for easy installation onto the wall • Surface mounting on wall using hardware after connecting to the power supply • IP : 65, IK : 08 • Cable entries for through-wiring of mains supply cable • Integral constant current power supply • CRI ( Ra) : >80 • Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply • Available CCT : 2700K, 3000K, 4000K, 5700K. Driver Power Supply : Integral, Input Voltage : 230-240Vac, Frequency : 50-60 Hz, Power Factor : ≥0.95, THD : <10%, Surge Protection : 4KV, Efficiency : >85%, Symmetrical Light Distribution.Product Finish options: Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. CE & BIS Certified. Inhouse NABL accredited lab. Brand Name : Philips, Product SKU : 919215850004 153 Supply of LED Linear Pendant luminaire is a versatile solution for projects that demand high quality of the lighting system and high visual comfort. With its modular design, the Revo-L can be used as an individual fixture or as a combination of luminaires put together in continuous lines • Luminaire made of extruded aluminium for better thermal management • polycarbonate diffuser for optimum optical performance, • Hexa-cell (Matte Black) secondary reflector • Suitable for surface and suspended mounting • Supplied with standard suspension kit (1metre).• Cable entries for through-wiring of mains supply cable • Integral power supply • Suitable for operation on 240V,50Hz single phase ac supply• Driver Power Supply : Integral, Power Factor : >0.90, THD : <10%, Surge Protection : 4KV-6KV, Efficiency : >85%, IP 44 Rating.• Dimension: 1188 x 36 x 75, 2365 x 36 x 75, 3540 x 36 x 75.• Wattage Options : Upto 40W, Upto 80W, Upto 120W.• Mounting: Pendant Mounting, Pendant Mounting, Pendant Mounting, Surface Mounting, Surface Mounting, Surface Mounting • Product Finish options: Pure polyester powder coated, RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 9016 Traffic White • CE & BIS Certified • Inhouse NABL accredited lab. Philips SP170P LED25S-6500 PSU W5L113 OD WH Smartbright Linear 154 Supply of Input power : 8W LED Bollard luminaire designed for surface mounted. Symmetrical light distribution. Luminaire madeof extruded aluminium alloy (grade 6063), die-cast aluminium of high corrosion resistance and non corrosive stainless steel fasteners. Translucent polycarbonate diffuser. Pressure die cast aluminium mounting plate Ø100.5mm x 4mm thick with 2 elongated holes 15 x 10 to suit M8 bolts at PCD55 for surface mounting on floor. The base plate have a cable entry hole of 70 x 24 mm dia at the center. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK08. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.9, THD <10%, Surge protection 2.5KV. Luminaire dimension : 106mm diameter x 565mm height. CE & BIS Certified. Foundation Bolt - 2 Nos of M8 Foundation J Bolt Length 150mm, 2 Nos of (Spring Washers, Plain Washers and Nuts) for each BoltInhouse NABL accredited lab. PHILIPS Bollard BCP100 LED 10W PSU GR L 750mm Solar Light 155 Supply of LED Linear Lighting to suit ceiling / wall is a slim and elegantly designed fixture, suited for varied applications offers a uniform, glareless and soft lighting.Al. Profile Housing Dimension: 1000 x 17 x 8, 2000 x 17 x 8Mounting: Surface Mounting, Product Finish: Anodized Aluminum• Luminaire made of extruded aluminium for better thermal management • PC clear / semi clear matte diffuser for excellent diffused lighting experience throughout the life of the fixture • Designed for mounting on ceiling / wall • Cable entries for through-wiring of mains supply cable • To be used with LED strip & power supply unit of suitable rating. Brand Philips Profile Shine 240 LEDs/m LED Strip | 3000K Warm White | High Brightness Linear Strip for Cove, False Ceiling, Architectural, Ambient Lighting 156 Supply of 24V 2835 Flexible LED Strip, 12W/m, Non-Integral, CCT: 2700K, 4000K, 6500KDimension: 5m / Roll, IP : 67, Brand Name : K-Lite, Code : 7289 or equivalent 157 24V Power supply, IP 67 Rated SMPS suitable for 24V LED Strip lights. Wattage: 150W, 24V Series Waterproof IP67 Power Supply24Vdc 6.25 Amps 150W Power unitDimension: 313 x 43 x 34IP : 67,Brand Name : K-Lite, Code : 8198 or equivalent 158 Supply and fixing of Fans and Air Circulator 159 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star rated complete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 2.5 metre down rod with fan clamp, and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 160 Supply and fixing of 600mm wall mounting Air circulator and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 161 Supply and fixing of 300mm(12)sweep (Heavy duty) AC Exhaust fan complete with necessary wall opening and making good of the wall and wiring to the near by point with 1.5 sqmm FRLS PVC insulated copper wires including necessaryaccessories and hardwares as required. 162 Supply and fixing oflouvers shutter arrangements for 300mm(12)sweep (Heavy duty) AC Exhaust fan complete 163 Supply and laying of following XLPE armoured LTUG cable in a trench/Tray with suitable cable tie tag etc as required. 164 Supply and Laying of 3 1/2 x 50 sq.mm. PVC Al.Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 165 Supply and Laying of 4C x 16 sq.mm. PVC AL. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.Main Panel to DB 166 Supply and Laying of 3C x 2.5 sq.mm. PVC Cu. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make goodMain Panel / DB to Street Lights 167 Supplying & Laying 120mm/103.5mm HDPE Pipe as per requirements including excavation & refilling. 168 Supply and fixing of double compression brass cable gland for following Aluminium conductorXLPE insulatedarmoured cable of 1100 V grade with earth connection. 169 Supply and fixing of brass cable gland for3 1/2 Cx 50 Sq.mm PVC LTUGAl. Armoured cable with earth connection 170 Supply and fixing of brass cable gland suitable for4C x 16 PVC Al. Armoured LTUG cable with earth connection. 171 Supply and fixing of brass cable gland for 3C x 2.5 sqmm COPPER cableLTUG cablewith earth connection. 172 Supply and providing cable end termination of the following sizePVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. Cable) 173 Supply and providing cable end termination of3 1/2Corex 50Sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. 174 Supply and providing cable end termination of 4 C x 16sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete. 175 Supply and providing cable end termination of 3C X 2.5 SqmmPVC LTUGCopper cable with necessary copper cable sockets by crimping etc, with electrical connection complete. 176 Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End (SD-375) 177 Wiring with 2 x 4 sq.mm. (56/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A 3/2 pin module socket with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colour for Concealed PVC pipe power Plug point ( 8 points / Coil)Higher End (SD-385) 178 Supply and fixing of 25A Flushtype Wall Socket 25A DPMCB complete set for ACPlug inflush with wall with earth connection (For AC Plug) 179 Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe Concealed inwall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copperwire and making good of the concealed portion withsuitable colour. ( SD 430 ) 180 Supply and Run of 2 Run x 2.5 sqmm and 1R of 1.5sq sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe onconcealed wall and ceiling with continuous earth wire connection with painting of suitable colour. 181 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 50mm and 2 mtr long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs of carbon based environment friendly backfill compound and suitable clamp andwithcopper earth plate of size 125mm x 50mm x 6mm with necessary funnelling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonrySD-233 182 Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection 183 Supply and Run of 1 of25.6.25 mm Al. Flat on wall / floor / ground for earth connection. 184 Supply and Run of 1 of25.6.25 mm Cu. Flat on wall / floor / ground for earth connection. 185 Supply, Installation, Testing and commissioning of 40 channel NVR with 4TB HDD * 4nos, Up to 40-ch 8 MP IP cameras can be connected, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by up to 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1/VGA1 outputs provided  HDMI1 Video output ) resolution Storage and Playback, Up to 4SATA interfaces and 1 eSATA interface for HDD connection, Support upto 6TB capacity for each HDD, Smart search for efficient playback.(Make: Hikvision/Dahua/Panasonic) 186 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse.All including suitable camera stand and accessories. (Make: Dahua/Panasonic) 187 Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Each Cameras, 1/2.8 CMOS,4 MP 2592 x1520 or better , triple stream, Min. Illumination required 0.005 Lux/F2.0 (Color,30IRE), 0 Lux/F2.0 (IR ON), 140dB True WDR, triple stream,3 to 12 mm, F1.4 to 2.8 , MFZ, Backlight Compensation, Highlight Compensation 3DNR, Privacy Mask, Internal/External Smart IR LEDs with up to 50m IR distance, H.265& |MJPEG, Inbuilt Video Analytics: Smart Motion Detection, Intrusion Detection, People Counting, Multiloitering, Face Detection, Line Crossing, Missing Object detection, [Unattended Object Detection. THe camera shall have inbuilt cyber security FIPS Chipset.Audio Stream Full Duplex, 1TB SD card support, IP 67 & IK10, Alarm: 1 In & 1out, PoE, H.265 High Profile and MJPEG, PoE Class . Certifications: ONVIF Profile S,G,T & M compliant, NDAA 889 UL, CE, EN, FCC & RoHS compliant and with all accessories and as per detailed tender specifications. 188 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung). 189 Supply and Clamping of CAT 6 armoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylenev. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 190 Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point( Point to Point ) Crimping, Testing and arrangement charges. 191 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 192 Supply and Fixing of Rack with Accessories -Higher end 12 U Rack with LNS unit and fan extra for the above rack. 193 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 194 PA SYSTEMS 195 Supply,installation, testing and commissioning of 30W High efficiency ABS horn loudspeaker with weather protectin IP 65Max Power : 45 W, Rated power, 30 Watts, Power tapping, 30/15/7.5W-Effective frequency range (-10 db) (-380 Hz to 5 kHz) - SPL at rated power (1 khz) 126 dB- Self extinguishing acc. to UL 94 VO - IP 65 acc. to IEC 60529, safety acc. to EN 60065. (Make - BOSCH) 196 Supply, installaion, testing and commissioning of 240W mixer amplifier with following features : inbuilt bluetooth for audio streaming, sports audio playback from USB pen drive, 4 microphone/line inputs, plus music source input, insert features to use as a pre/power amplifier, Optional 2 tone chime generation for input 1 technical specifications - Frequency response 80 Hz to 18 kHx (+1/-3 dB W - 10 dB ref. rated output) - Distortion <1% @ rated output power, 1 kHz bass control Max +/- 8 dB Treble control max +/- 8 dB. (Make - BOSCH) 197 Supply, installation, testing and commissioning of Goose Mic 198 Supply and installation ofHandheld microphone with a dynamic transducer element that shall be designed for high speech intelligivility. It should have a rugged enclosure is both stylish and easy to use in a wide range of public and sound reinforcement applications. Polar Pattern unidirectional, frequency range 80 hZ to 12 kHz, Sensitivity 1.7mV/Pa +/- dB, Rate out impedance 600 Ohms. (Make BOSCH) (Market rate) 199 Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., asper standard methods and as directed by the Departmental Officers. 200 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 201 Supply and erection, testing and commissioning of 2.0 TR (6000K.cal/hr) ABS Split type Air conditioner (3 star rating)confirming to IS : 1391(part-2) 1992 with Admt No.1 fitted withhermetically sealed air compressor operating on refrigerant R-410A suitable for wall mounting for operation on 230V 50 HZsingle phase AC supply inverter technology with capable of thefollowing performinga) Coolingb) Dehumidifyingc) Air circulatingd) Filteringe) Refrigerant pipe lines – 6 mtr lengthThe installation works for the above split type AC units includethe following1. Mounting / fitting indoor and outdoor units at theirrespective locations2. Laying refrigerant pipe line of required length notexceeding 6 meters distance & connecting both units afterdrilling hole/holes in the wall is required, thickness of the coppertubing shall not be less than 0.7 mm3. Installing the section pipe with expanded polythene foamtubing4. Laying drain pipe to throw out the condensate water beingformed within indoor unit5. Leak testing the entire system unit6. Charging refrigerant gas in the unit7. Suitable electrical wiring with to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoorunit upto 6 meter length and upto switch within 3 meters oflocation of indoor unit. (Like (Carrier / Voltas / Blue Star /Equivalent) as directed by the department officers 202 Supply and fixing of 5 KVA slim and wall mounting (V Guardmake ) double booster voltage stabilizer for operation on 170-230V 50Hz single phase AC supply capable for 2 TR split ACwith necessary inter connection and earth connection as directedby the departmental officers. 203 LANDSCAPE 204 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 205 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 206 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 207 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 208 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 209 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 210 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
50.
Housing Urban and Rular Development #10217851 Price Bid
Tender For Redevelopment Of Murasoli Maran Park North Located At Perambur.; 1 Dismantling plain cement concrete work and clearing the debris etc., complete as directed by the engineer-in-charge 2 Dismantling GI Sheet with posts 3 Dismantling the existing brick or stone masonry work in cement mortar under 3m high including clearing away and carefully stacking materials useful for re-use etc., complete as directed by the engineer-in-charge 4 Dismantling R.C.C.works,carefully clearing away the debris as directed during execution. The dismantling of concrete as per PWD schedule of rates are to be adopted wherein a part part of the concrete only is to be dismantled and the remaining part of the concrete has to be retained structurally safe. 5 Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 6 Narrow Foundations for building & culvert - First Depth Upto 2m 7 Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. 8 Refilling with excavated earth in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification. 9 Supplying and filling with earth up to 10 Km for foundation and basement, etc., including watering and consolidating, etc., complete complying with standard specifications and as directed by the engineer-in-charge 10 Construction of Wet Mix Macadam 150 mm compacted thickness in two layers by providing laying , Paving , and compacting of aggregate gradation satisfying to Table 400-13 of MORTH and satisfying he physical paraemeteres as per MORTH Table 400-12, mixing in a Wet Mix Plant of 200 tonne capacity at OMC , carriage of mixed material to work site and laid in sensor pavers tc the required line and grade as per the drawing and compacted with vibratory roller of 8-10 tonne to achieve the desired density of 98% of Maximum dry density and as per the direction of the Engineer In-Charge of work 11 Supplying and filling of well gravel by lorry in basement filling including conveyance loading and unloading charges and all other incidential charges filling laying watering and consolidation etc., complete as directed by the Dept., Officers with standard specification. 12 Supplying and filling in foundation, basement, etc with Crushed Stone sand filling in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 13 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 14 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 15 Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid). 16 For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. 17 For column footing plinth beam bed blocks templates staircase, steps piers, raft beam, raft slab etc. 18 Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 19 Foundation and Basement 20 For Ground Floor 21 Providing and laying in position, Standardised Concrete Mix M-30 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 22 For Foundation and basement 23 For Ground floor 24 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire) 25 Supplying,fabricating and errectingStainless steel (Grade SS316) Channel fabricated and connecting with plates of 6 mm thick. The rate inclusive of cost of Stainless steel Channel section, plate, cleat angle, necessary bolts and nuts, labour charges for welding, fabricating & erectingetc., complete and as directed by the departmental officers. 26 Random Rubble in Lime Mortar etc., Complete complying with standard specification and as directed by the Departmental Officers. 27 For Foundation and basement 28 For Ground floor 29 Brick work in Cement Mortar 1:3 using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9 x 4-3/8 x 2-3/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 30 For foundation & basement 31 In Ground floor 32 Outer Plastering with Cement Mortar 1:4 (One cement and Four sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 33 Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 34 Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 35 Paving the floor/dadooing with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Jet black with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification 36 Paving the floor/dadooing with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Flamed steel grey granite slab with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification 37 Nosing the granite slab - single nosing as directed by the engineer-in-charge 38 Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. 39 Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights.The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc.The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147.Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer 40 Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification 41 Art work as per the direction of department official, over Oil Painting with first class quality and approved colour including a priming coat with thorough scrapping clean removal of dirt., etc., complete and including necessary plaster of paris, putty, etc., wherever required (Relevent ISI STD), excluding putty works. 42 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between.The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 43 Providing granolithic floor finish of 50 mm thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers) 44 SOLID BLOCKS 40X20X20 CM Supplying and fixing Solid Blocks of following size confirming to S.S. 2145-1965 (including jam blocks closers etc.) made in CC 1:3:6 (One Cement Three Sand and Six HBSJ 6 mm) in CM 1:5 (one cement and five sand),for masonry wall partition wall including curing neat finishing etc. complete 45 Best Tiled roofing with Mangalore tiles, set in lime mortar 1:2 over flat tiles (15cm x 15cm x 12mm) and including teakwood reepers (50 x 12 mm), etc., complete as per standard specifications and directed by the engineer-in-charge 46 Supply and fixing ofPortable Store room of size8x8x7 and type PUF with following specifications:Structure: The supporting column at corners is made out of SHS 70mm pipe welded between The top and Base frames. The structural base frame work made out of 2mm thick SHS 70 pipe as peripheral frame work and RHS 60 x 40, RHS 60 x 40 & SHS 25 as intermediate support to Form a grid of 600mm x 600mm both ways to support the flooring. The structural Top frame work made out of 2mm thick RHS 60 x 40 pipe as peripheral frame work and RHS 60 x 40 & SHS 40 as intermediate support at an interval of 1200mm to support the roof. with 150mm Extended Leg in all Corners (Column)Flooring: The 18mm Cement particle Board place on the top of Bottom frame and Proper fasteners with Vinyl flooringRoof: The roof panels shall be made of TCT Pre coated Profile steel sheets on both side and inner portion made of PUF. Total thickness of roof panel shall be 30mm. With single side slope of roofWall:The Wall panels shall be made of TCT Pre coated Profile steel sheets on both side and inner portion made of PUF. Total thickness of roof panel shall be 50mm.Door:Standard Puf panel Door-1 No with Pad Lock out side and Altrop insideElectrical: Switch and Socket-2No’s, Tube light-1No’s inside, outside Bulk head fittings 1No.Complete, etc., as directed by the engineer-in-charge 47 Supply and fixing of Portable Security Cabin of size 6x6x7 and type PUF with following specifications:Structure:The supporting column at corners is made out of SHS 70mm pipe welded between The top and Base frames. The structural base frame work made out of 2mm thick SHS 70 pipe as peripheral frame work and RHS 60 x 40, RHS 60 x 40 & SHS 25 as intermediate support to Form a grid of 600mm x 600mm both ways to support the flooring. The structural Top frame work made out of 2mm thick RHS 60 x 40 pipe as peripheral frame work and RHS 60 x 40 & SHS 40 as intermediate support at an interval of 1200mm to support the roof. with 150mm Extended Leg in all Corners (Column)Flooring: The 18mm Cement particle Board place on the top of Bottom frame and Proper fasteners with Vinyl flooringRoof: The roof panels shall be made of TCT Pre coated Profile steel sheets on both side and inner portion made of PUF. Total thickness of roof panel shall be 30mm. With single side slope of roofWall:The Wall panels shall be made of TCT Pre coated Profile steel sheets on both side and inner portion made of PUF. Total thickness of roof panel shall be 50mm.Window:1mx1m Aluminium Glass Sliding window-3No’s.Door:Standard Puf panel Door-1 No with Pad Lock out side and Altrop insideOthers:Writing Pad-1 No.Electrical: Switch and Socket-2No’s, Tube light-1No’s inside, outside Bulk head fittings 1No., Wall mounted fan - 1 No.Complete, etc., as directed by the engineer-in-charge 48 Supplying and fixing of Semi polished granite stone bench of 5 feet length with 1.5 feet width, backrest 2 feet height, seating height of 1.5 feet from floor level and of material thickness 50 mm, including cost of materials, labours and conveyance charges, etc., complete, as directed by the engineer-in-charge 49 Supplying And Fixing of Rubber Moulded Grey Premium Concrete Kerb of Size 450X125X300mm Using M30 Concrete. The Concrete Shall Be Moulded By Table Mount Vibrated With Polypropylene Fibers At 5% And Curing Compound. The Rate Shall Include Cost of Materials Transportation Loading Unloading Charges And All Taxes Including Necessary Earth Work Pointing With cm. 1:3 To Full Depth Curing Thread Lining Etc Complete 50 Supplying and laying hydraulic pressed monolithic natural grey colour cement concrete inter locking paver block of 63mm thick, in cement concrete 1:2:4 (one cement, two sand, four aggregate) using difference design and with stand for pressure of 150 - 200 kg/m2 over the existing sand cushion by using earth rambers and also vibratting the concrete blocks often laying using plate vibrators etc, complete as directed by the departmental officers. 51 Paving the floor/dadooing with best approved quality Rough Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Jet black with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification 52 Painting with two coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 53 Supplying and laying Pebble Flooring walkpath (8-shape) of walkpath area of 32 Sqm in cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and pointedwith same colour of cement etc., complete as per standard specification 54 Providing and laying EPDM Flooring (Ethylene Propylene Diene Monomer) of 36mm thickness with proper laying materials of approved sample as per design / drawing laid compacting, levelling to required slope, finishing neatly. The rate including cost of all materials, labour charges, transportation, loading & unloading and all incidentals etc. complete complying with relevant standard specification and as directed by the Engineer-in-charge. 55 Cut Stone in Lime Mortar etc., Complete complying with standard specification and as directed by the Departmental Officers. 56 Scaffolding charges for Vimanams and Gopurams with casurina posts coconut or palm trees wherever necessary for main, form work and providing with net lawn / PVC mesh coverings, providing ladder arrangements, country wood plank for working, inspection etc. complete, hire charges only for erection, maintenance and removing the same on completion of the work. 57 Upto 15 58 Upto 25 59 Supplying and laying Stone for gopuram and Thoon the rate inclusive of cost of materials, conveyance and labour charges, lifting charges etc., 60 Charges for Designing the gopuram stone like ubabeedam pathmajagathi, ubabeedam kandam and ubabeedam kabothagam, Sthambavari, Kabothaga Vari etc., 61 Ubabeedam Pathma jagathi 62 Ubabeedam - kandavari/ thaddi vari set 63 Ubabeedam - kabothagam 64 Adhirstanam - padma jagathi vari 65 Adhirstanam - kandavari/ thaddi kudam set 66 Adhirstanam - Kabothagam 67 Adhirstanam - Kumuthaga jagathi 68 Adhirstanam - jagathi 69 Adhirstanam - kumuthaga vari 70 Sthambavari 71 Thadikudam set 72 Veerakandagam pothigai 73 Uthiram 74 Kabothagam 75 Viyalavari 76 Thoon 77 Simmam 78 Laying cut stone flooring using new stones 0.60 x 0.60 m not less than 10 cms thick. The Rate inclusive of labour charges, materials, and coveyance charges etc., 79 ELECTRICAL WORKS 80 TNEB METERING BOARDMetering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, floor mounted, single front,14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., including all associated control wiring. 1set of 160A with TNEB Metering provision. 81 Supply and fixing of 125A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with PWD earthing. 82 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steel powder coated MCCB Indoor Panel Board, made up of 2mm powder coated, including bus bar provision of double door with industrial lock with Multifunction Meter 1no andMain 1no 125A 4Pole MCCB I/C, 2nos 100A 4Pole MCCB,2nos of 63A 4Pole MCCBs and 2nos of 32A 4Pole MCCBs for O/Gwith suitable copper bus bar (33x6mm) having three phase Multifunction meter with line indicators for erecting the indoor panel board complete etc., The above panel board is to be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel etc. complete. 83 VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB :Supply and fixingof8 way verticalTPMCBsheetsteelTPMCB DB with IP42 Protection of surface type fitted with bus bars and neutral links with1 No. of 40A FP MCB as Incoming and 8 Nos.of 32A,10KA Triple Pole MCB in Flush with wall and making good of the concealed portion with earth connection. (TPMCB DB with IP42 Protections) 84 VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB :Supply and fixingof8 way verticalTPMCBsheetsteelTPMCB DB with IP42 Protection of surface type fitted with bus bars and neutral links with1 No. of 40A FP MCB as Incoming and 8 Nos.of 32A,10KA Triple Pole MCB. The MCB DB and MCB should be with ISI mark.The above Three Phase VDB is to be erected on masonary pedestal 2nos including earth work excavation, for a depth of 2feet, PCC 1:2:4of 800mm depth, 2.5feet height concreate bed, plastering, painting etc., with earth connection. (TPMCB DB with IP42 Protections) 85 Supplyandfixingof 7segment 8way40 AFP MCBsheet steel distributionboard(Higherend)withmetal/acrylicdoor coverflushtype /surface type fittedwith busbarsandneutral linkswith single /threephase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 40 A FP MCB, 10kA, and another separate 4 way for accommodating one no. 40 Amps 4 pole MCB/ ELCB / RCD (totally 8 ways in one segment) ( 3x6ways in each segment ) and Seperate Provision for MCB / Isolators (totally 18nos) for sub incomers in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only. i.40A 4Pole MCB - 1no.ii.32A 2Pole MCB - 3nos.iii.6A to 32A SP MCB - 24nos.The MCB DB and MCB should be with ISI mark.The above Three Phase 8way CDB is to be erected on masonary pedestal 2nos including earth work excavation, for a depth of 2feet, PCC 1:2:4of 800mm depth, 2.5feet height concreate bed, plastering, painting etc., with earth connection. 86 Supplyandfixingof 7segment 12way40 AFP MCBsheet steel distributionboard(Higherend)withmetal/acrylicdoor cover fitted with busbarsandneutral linkswith single /threephase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 40 A FP MCB, 10kA, and another separate 4 way for accommodating one no. 40 Amps 4 pole MCB/ ELCB / RCD (totally 8 ways in one segment) ( 3x6ways in each segment ) and Seperate Provision for MCB / Isolators (totally 18nos) for sub incomers in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. with the following : i.40A 4Pole MCB - 1no.ii.32A 2Pole MCB - 3nos.iii.6A to 32A SP MCB - 36nos. The MCB DB and MCB should be with ISI mark.The above Three Phase 8way CDB is to be erected on masonary pedestal 2nos including earth work excavation, for a depth of 2feet, PCC 1:2:4of 800mm depth, 2.5feet height concreate bed, plastering, painting etc., with earth connection. 87 Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 88 Supply and laying of following XLPE armoured LTUG cable in a trench / Tray with suitable cable tie tag etc as required. 89 SupplyandLayingof3 1/2Cx70sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 90 SupplyandLayingof3 1/2Cx35sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 91 Supply and Laying of 4C x 16 sq.mm. PVC armoured LTUG cable in suitable sizeHDPEpipeinatrenchto beexcavatedatadepthof0.75metreand refilling the earth to make good. 92 Supply and Laying of 4C x 10 sq.mm. PVC armoured LTUG cable in suitable sizeHDPEpipeinatrenchto beexcavatedatadepthof0.75metreand refilling the earth to make good. 93 Supplying and Laying of 3C X 4 sqmm Flexible Multicore Cable manufactured with electrolytic grade flexible copper with FRLS conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 in suitable size of HDPEpipeinatrenchtobeexcavatedatadepthof0.75metreand refilling the earth to make good. 94 Supplying and Laying of 3C X 2.5 sqmm Flexible Multicore Cable manufactured with electrolytic grade flexible copper with FRLS conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 in suitable size of HDPEpipeinatrenchtobeexcavatedatadepthof0.75metreand refilling the earth to make good. 95 Supply and Clamping of 4C x 16 Sq.mm PVC armoured LTUGaluminium cableonpostoronwallwithMS-clamps,saddles,plugs,screwsetc.,complete including transport charges of UG cable. 96 Supply and Clamping of 4C x 10 Sq.mm PVC armoured LTUGaluminium cableonpostoronwallwithMS-clamps,saddles,plugs,screwsetc.,complete including transport charges of UG cable. 97 Supply and fixing of double compression brass cable gland for following Aluminium conductorXLPE insulatedarmoured cable of 1100 V grade with earth connection. 98 Supply and fixing of brass cable gland for3 1/2 Cx 70 Sq.mm PVC LTUG armoured cable with earth connection. 99 Supply and fixing of brass cable gland for3 1/2 Cx 35 Sq.mm PVC LTUG armoured cable with earth connection. 100 Supply and fixing of brass cable gland suitable for 4C x 16 Sq.mm PVC armoured LTUG cable with earth connection. 101 Supply and fixing of brass cable gland suitable for4C x 10 PVC armoured LTUG cable with earth connection. 102 Supply and providing cable end termination of the following sizePVC LTUGaluminiumarmouredcablewithnecessaryaluminiumcable socketsbycrimpingetcwithelectricalconnectioncomplete(copper sockets for copper cables and Alu. Sockets for alum. Cable) 103 Supply and providing cable end termination of 3 1/2Corex 70 Sq.mm PVC LTUG Aluminium armouredcablewith necessary aluminium cablesockets by crimping etc., with electrical connection complete. 104 Supply and providing cable end termination of 3 1/2Corex 35 Sq.mm PVC LTUG Aluminium armouredcablewithnecessary aluminium cablesockets by crimping etc., with electrical connection complete. 105 Supply and providing cable end termination of 4 C x 16sq.mm PVC LTUG Aluminiumarmouredcablewithnecessaryaluminiumcablesocketsby crimping with electrical connection complete. 106 Supply and providing cable end termination of 4 Cx10sq.mm PVC LTUG Aluminiumarmouredcable withnecessaryaluminiumcable socketsby crimping with electrical connection complete. 107 Supply and fixing of Timer Extended Product Type AD1CO-R-15m, Long Description Analog time switch, daily proramming, 1 channel CO, 15 minutes switch, with reserve, Function : Daily, Maximum Load Capacity : Resistive load 16 A Inductive Load 4 A,Power Supply : (-15%..+10%) 230 V AC, Contact Type : Change-Over (CO), Meter Type : Electromechanical , Options Provided : With running reserve, Battery Chemical Composition : Nickel-Metal Hydride, Battery Life : 150 hour, Battery Type : Button Cell, Battery Weight : 0.004 kg, Number of Batteries : 1, Rated Operational Voltage : 230 V, Operational Voltage : Maximum (Incl. Tolerance) 195 V AC, Maximum (Incl. Tolerance) 253 V AC, Rated Frequency (f) : 50 - 60 Hz, Maximum Switching Power : 4000 W, Low Consumption Lamp (CFL) 2500 W LED 900 W, The rate is inclusive of necessary connecting accessories etc., complete. Contactor Extended Product Type AX65 - 30-11-80, CAD Dimensional Drawing : 2CDC001079B0201, Number of Main Contacts NO : 3, Number of Main Contacts NC : 0, Number of Auxiliary Contacts NO :1, Number of Auxiliary Contacts NC : 1, Rated Operational Power AC-3 (Pe) (415V) 37 kW, General Use Rating UL/CSA : (600 V AC) 90 A, Low Voltage Products and Systems → Control Products → Contactors → Block Contactors → AX Contactors → AX65 ( Make : ABB, Product ID 2CSM208151R1000, TIMER ), ( Make : ABB, Product ID 1SBL371074R8011, CONTACTOR ) 108 Indoor and Outdoor Lights 109 Supply & Installation of Customised 60W Juno-Column light luminaire designed for surface mounted. Shielded light distribution. Luminaire made of spun aluminium with extruded aluminium alloy (grade 6063) and non corrosive stainless steel fasteners. Translucent acrylic diffuser. Pressure die cast aluminium mounting plate 250mm dia round x 12mm thick with 4 elongated holes 38 x 19 to suit M16 bolts at CC 140 with pure polyester powder coating.The base plate have a cable entry hole of 65mm dia at the center. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. Protection class IP65. Mechanical resistance IK08. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >88%, Power factor >0.95, THD <10%, Surge protection 6KV. Luminaire dimension : 600mm dia round x 3500mm height. CE & BIS Certified. Inhouse NABL accredited lab with LM 79 Testing facility. The rate is inclusive of Foundation Bolt - 4 Nos of Necessary M16 Foundation workJ Bolt Length 300mm, 2 Nos of (Spring Washers, Plain Washers and Nuts) for each Bolt - Suitable for Juno Column Lighting. ( Make : Model No. KL7034 or equivalent ) 110 Supply & Installation of Customised 36W pole top Juno Midi luminaire. Beam angle 120°. Luminaire made of spun aluminium, integrated with extruded aluminium pipe along with pressure die cast aluminium base through supporting arms made fo gravity die cast aluminium and non corrosive stainless steel fasteners. Diffuser placed into the provision formed on the pheriphery of the bottom cover. Translucent acrylic diffuser. Suitable for mounting on Ø50mm OD pipe. Protection class IP65. Mechanical resistance IK07. Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. LIGHT LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD <10%, Surge protection 4KV. Luminaire dimension : 420mm diameter x 430mm height. CE & BIS Certified. Inhouse NABL accredited lab. ( Make : Model No. KL 5380 or equivalent. ) 111 Supply and fixing of Outdoor Termination PVC Box. The cost is inclusive of gland, lugs and termination) with all fixing accessories etc., complete. 112 Supply & Installation of 50W LED compact and robust flood light luminaire designed to provide uniform illumination in open spaces. Beam angle 10°. Extruded aluminium hood cover integrated with die-cast module and extruded aluminium alloy tube (grade 6063), excellent thermal management heat sink & polycarbonate optical lens. Adjustable clamp made of stainless steel (2mm thickness) to facilitate proper aiming of the luminaire at desired angle. Pressure die cast aluminium mounting plate Ø100.5 x 4mm thick with 2 elongated holes 15 x 10 to suit M8 bolts at PCD 55 with pure polyester powder coating. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. Cable entrance via PG9 cable gland. All external screws are made of stainless steel. Protection class IP65. Mechanical resistance IK09. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. RGBW, Colour rendering index (CRI)>80. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.90, THD< 10%, Surge protection 6KV. Luminaire dimension : 166mm diameter x 168mm width x 584mm height. CE & BIS Certified. Inhouse NABL accredited lab. ( Make : K-LiTE KL 4331or equivalent ) 113 Supply & Installation of 12W LED surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass of 4mm thickness. Pressure die-cast aluminium surface mounting base. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66. Mechanical resistance IK07. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 6500K, Colour rendering index (CRI)>80. High Quality LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.95, THD <10%, Surge protection 4KV.Luminaire dimension : 113mm length x 84mm width x 117mm height. CE & BIS Certified. Including accessory Visor. Inhouse NABL accredited lab. ( Make : Model No. KL 4268 or equivalent. ) 114 Supply & Installation of 12W LED spike mounted compact spot light designed to provide directional light.Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass of 4mm thickness. Surface mounting spike made of polypropylene. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66. Mechanical resistance IK07. Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 6500K, Colour rendering index (CRI)>80. LIGHT LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.95, THD <10%, Surge protection 4KV.Luminaire dimension : 113mm length x 100mm width x 451mm height. CE & BIS Certified. Including accessory Visor. Inhouse NABL accredited lab. ( Make : Model No. KL 4267 or equivalent. ) 115 Supply & Installation of 16W LED Bollard luminaire designed for surface mounted. Symmetrical light distribution. Luminaire made of extruded aluminium (grade 6063), pressure die-cast aluminium components of high corrosion resistance and non corrosive stainless steel fasteners. Reflector system made of spun aluminium (powder coated white). Clear polycarbonate diffuser. Pressure die cast aluminium mounting plate 167mm diameter x 4mm thick with 4 elongated holes 20 x 14 to suit M12 bolts at PCD 110 for surface mounting on floor. The base plate have a cable entry hole of 75mm dia at the center. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK10. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. High Quality LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.95, THD <10%, Surge protection 3KV. Luminaire dimension : 166mm diameter x 970mm height. CE & BIS Certified. Inhouse NABL accredited lab. The rate is inclusive ofFoundation Bolt - 4 Nos of M12 Foundation J Bolt Length 300mm, 2 Nos of (Spring Washers, Plain Washers and Nuts) for each Bolt with suitable civil foundation etc., complete. ( Make : Model No. KL 5565 or equivalent. ) 116 Supply & Installation of 6W LED compact and robust wall recessed luminaires for illuminating walls and stairs. Forward asymmetrical light distribution. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. ABS plastic installation housing for preparing the recess opening in wall / stairs. Clear acrylic diffuser. Single cable entrance via M10 cable gland. Protection class IP65. Mechanical resistance IK09. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. High Quality LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.90, THD <10%, Surge protection 2KV. Luminaire dimension : 130mm length x 87mm width x 76mm height. Luminaire installation in a recessed opening cut-out dimension : 124mm length x 83mm width x 70mm height. CE & BIS Certified. Inhouse NABL accredited lab. ( Make: Modle No. KL 2747 or equivalent. ) 117 Supply & Laying ofNiva 15 surface mounted compact flexible linear LED lightingwith system wattage of 9W/m. Beam angle 120° diffused. Luminaire housing and diffuser made of silicone, UV proof for true outdoor application. High light transmittance, environmental silicone material. Top bendable. Cut-able for flexible application. Even light distribution & no hot spots. Aluminium mounting profile / Flexible mounting channel for surface mounting on ceiling / wall / floor. Protection class IP67. Mechanical resistance IK08. Available colour temperature 3000K (Other CCTs on request), Colour rendering index (CRI)>80. Operating temperature range is from -15°C to +50°C. Constant voltage non integral power supply at 24Vdc assures safety. Luminaire dimension : 1000mm length x 15mm width x 15mm height. KL 8399 - Mounting Chain Included. Inhouse NABL accredited lab. ( Make: LIGHT ID : 3396 or Equivalent. ) 118 Supply and fixing LED Control Driver of 24V Series Waterproof IP67 Power Supply 24V DC, 6.25 Amps 150WDimension: 313 x 43 x 34. The rate is inclusive of labour charges etc., complete.( Make : KL-8198 ) 119 Supply & Installation of 7M height Brussel pole made of circular mild steel pipe of two section (grade YST 210) which is fabricated using 139.7mm diameter x 3.6mm thick base section with height of 2000mm, the top section is 88.9mm diameter x 2.9mm thick with minimum height of 4978mm. & 4 Nos. of Die-cast aluminium mounting clamp (126mm dia x 60mm height) for fixing 8 Nos. of 50Wflood light luminaires. Pole mounted flood light luminaires. Extruded aluminium hood cover integrated with die-cast module, excellent aluminium heatsink for thermal management with vertical fin design for longer life of the LEDs. Bracket to facilitate proper aiming of the luminaire at desired angle. Protection class IP65 optical compartment with polycarbonate optical lens and Mechanical resistance IK10. The luminaire provided with beam angle 10° / 28° / 45° (Symmetrical light distribution). Available colour temperature 2700K / 4000K / 5700K, colour rendering index (CRI)>/=80. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >85%, Power factor >0.95, THD< 10%, Surge protection 6KV. electrical Class I wattage 50W ± 10%. High power LED (Make: Nichia) with Macadam 120 Inhouse NABL accredited lab. The pole is to be provided with a surface mounting suitable base plate 300 mm square x 16 mm thick steel of grade E250 to IS 2062 : 2011. All dimension are within +/- 5% tolerance. Pole section welded by certified welders using high end MIG welding processes. 3Nos. of PDC aluminium service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable, 6A SP MCB and 32A Ramanuj stud type 4 way terminal block for loop-in / loop-out arrangement, 5A 2 Way terminal connector and provision for earthing. Any other internal cables and connections shall not be covered in the scope of supply. The mild steel mounting base plate. The mounting plate provided with 4 elongated holes 48 x 24 to suit M20 x 500mm bolts of grade 4.6 at CC 215 for alignment of the pole. The base plate have a cable entry hole of 70mm dia at the center. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. After fabrication, entire pole is shot blasted (Inhouse). The pole is coated with zinc rich primer & pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey / Anthracite grey / Black as standard colour options. ( Make: K-LiTE ID : 1063 or Equivalent. ) 121 Supply & Instalaation of 60W Cylin Mega Compact and efficient ceiling mounted down lighters. High protection class & lumen output makes it versatile solution for both indoor & outdoor applications• Luminaire made of pressure die cast aluminium with non corrosive stainless steel fasteners. IP 65• Clear toughened glass.• Silicone gasket.• Polycarbonate optical lens.• Surface mounting on ceiling using hardware after connecting to the power supply.• Cable entries for through-wiring of mains supply cable.• Integral constant current power supply• CRI (Ra) : >70• Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply.• CCT : 2700K, 3000K, 4000K, 5700KMandatory CE Marking, BIS Certification, LM 79 report, IP, IK Report from NABL accredited Lab. ( Make: K-LiTE, Model No.KL 3628) or equivalent. 122 SupplyandFixingof 40W4 LEDTubewith Light fittingTW round blockfixing ceiling or on wall withPVCunsheathed copper leadsfrom terminalsto the fitting. (Make : Philips / Crompton / Havelles ). 123 supply and fixing of 1200mm (48) sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18). 124 Supplyandfixingof375mm (15) sweep(Heavyduty)ACExhaustfan completewithnecessarywallopeningandmakinggoodofthewalland wiring to the near by point with 1.5 sqmm FRLS PVC insulated copper wires including necessaryaccessories and hardwares as required. 125 Supplyandfixingof louversshutterarrangementsfor300mm(12)sweep (Heavy duty) AC Exhaust fan complete. 126 Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling withModule GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection by 1 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.). 127 Supply and fixing of 2Nos 6A modular (2 in one 3pinsocket)wall socket with control switches and 1 No. 6A/16A 3pin switched socket (16A Switch and Socket combined) with suitable MS modular box covered with Modular 9 module whiteplate on wall with earth connection (For cctv monitor socket) 128 Supply and fixing of 1 No. 6A/16A 3pin switched socket(16A Switch and Socket combined) with control switch (Crabtree / Legrand / Hager / Equivalent) in suitable MS modular Box covered with Modular 3module whiteplate in wall with earth connection. 129 Supply and installation maintenance free GI Earthing System comprising of 50mm dia and 2 mtr. long earth electrode oflow carbon steel rod with 100 micronbondingand25kgs.ofcarbonbasedenvironmentfriendlybackfill compound and suitable clamp. 130 Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. 131 Supply and Run of 1 of No.8 SWG Copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. 132 Supply and Run of 1 of No.8 SWG GI wire in suitable PVC rigid pipe on wall / floor / ground for earth connection. 133 Coil earth to street light poles with No.8SWG GI wire of 11.5metres of length in which 10metres of total length compressed into a coil of one meter length (75mm to100mm dia ) connected suitable with hexagonal earth bolt of size 8mm in to 25mm welded on the pole at one end with a coil position fixed on the earth. 134 Supply and fixing SFRC manhole chamber size 750 x750 mm square manhole cover onlyUsing M30 concrete rate includes of excise duty,Transporation charges, all other materials whichever necessary and labour charges etc as directed by the departmental officers. 135 Supply and Laying in position the best quality and 120mm diaHDPE pipes of ISI mark, providing leak proof joints etc and making connectin to all sanitary fittings, including dismantling masonry / RCC works whereever necessary and making good the dismantled portions to the original condition complying with standard specification. 136 Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with6THardDiskDrive4nos,NewlogicalandvisualizedGUIdesign Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected, ConfigurablenormalorhotspareworkingmodetoconstituteanN+1hot sparesystem VideoInputandTransmission,Connectableto thethird-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at upto12MPresolutionHDVideoOutput□HDMI1/VGA1outputs provided□HDMI1Videooutputatupto4K(3840×2160)resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature differencedetectiontriggeredvideofiles,POSinformationoverlayonlive view and playback, POS triggered recording and alarm Network & Ethernet Access□Hik-Connectforeasynetworkmanagement,2GigabitEthernet network interfaces. 137 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS,●3840×2160@15fps,2.8/4mmfixedlens,01lux@(F1.2,AGCON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection● 120dB WDR,● BLC/3D DNR/ROI, IP67 complied●On-boardStorage - Built-inmicro SD/SDHC/SDXCcardslot,upto128 GB,● Shutter Speed 1/3 s to 1/100,000 s,● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°,● rotate: 0° to 360°, 2.8 mm,● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°,●Lens Mount M12 ● IR Range I5: up to 50 m,●ImageSettingsRotatemode,saturation,brightness,contrast,sharpness adjustable by client software or web browser,●PowerConsumptionandCurrent-12VDC,0.7A,max.7.5WPoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W●Cameraoutfittedwithmetalhousingsoastopreventthelensfrom damages during physical abuse. 138 IP BASED VARIFOCAL LENS DOME CAMERA: Supply, Testing and Commissioning of 5MP Varifocal Motorized Dome IP Camera with following specification: Image Sensor: 1/2.7” Progressive Scan CMOSEffective Pixels:2592 × 1944Shutter Speed:1 s to 1/100,000 sS/N Ratio:≥52 dBAngle Adjustment:Pan : 0°~360°, Tilt : 0°~77°, Rotation : 0°~360°Video Compression: H.265 / H.264 / MJPEGH.264 Compression: Standard Base Line / Main Profile / High ProfileH.265 Compression: Standard Main Profile @ Leve4.1 High TierResolution : 5MP(2592×1944), 4MP(2560×1440), 3MP(2304×1296), 1080P(1920×1080), 720P (1280×720),D1, CIF, 480×24030m IR, Micro SD Slot, Ingress Protection: IP67Digital Zoom: YesImage Features: Defog, BLC, HLC, 2D/3D DNRCorridor Pattern: YesVideo Privacy :4 zones video maskPower Supply: DC12V / PoEPower Consumption: < 9.5W. 139 Supply, Installation, Testing and Commissioning of 42 smart LED TV with following specificationsa) Full HD 1920 x1080 (4K monitor)b) IPS panelc) Slim back light LED moduled) 900 PMIe) Triple XD enginef) Dynamic scanningg) ANRh) True colour generatori) 8modes of picturej) picture wizardIIIk) Real cinema 24Pl) HDMI -3nosm) USB -3nosn) Built in LANo) Magic remotep) Dimension 1242 x 724 x 55.1min(37).(Make: Sony/ LG /Samsung). 140 Supply and fixing of outdoor4X6PVC box with 102mm x 77mm x 102mm with all fixing accessories. 141 Supply and Laying of CAT 6 armoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylenev. Twisting - 2 Cores to the pairvi. Cable lay up - 4 Core to the pairIt has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 142 Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 143 Supply and laying of armoured, Singlemode, Thermoplastic Tape Inner Sheathed, PVC type sheathed 6 core Optical Fibre Cable withunique fiber excess length control method provides the cable with excellent mechanical and environmental properties and Cable - 2 Embedded FRP provides tensile strength & Anti-buckling properties. It is processed with Filling jelly - Thixotropic jelly to prevent Water ingress in loose tube. 144 Fixing and Termination of Optical Fibre Cable Single Point ( Point to Point ) Splicing and arrangement charges. 145 Supply and fixing of OFCPVC Black Colour Box 1x 3/4 x2 PVC Black colour Box. 146 Supply and fixing of 24 Port 2SFP with Module, PoE Giga Range Lan Switch.• 24Ports10/100/1000 Base-TPoE+ 4 x Combo Gigabit UTP or Gigabit SFP slots• Support IEEE 802.3af (PoE) and 802.3at (PoE+) Standard• Equipped with IEEE 802.3az Energy Efficient Ethernet (EEE) Complaint• SupportIEEE 802.1Q VLAN traffic segregation• Access Control List (ACL) feature to enhances network security• Auto Surveillance VLAN for easy integration with IP-based surveillance systems• Loopback detection (LBD) and broadcast storm control to avoid network downtime• Quality of Service (QOS) and bandwidth control to ensure smooth operation• Support Web-based GUI, Smart Console , Network Assistance Utility• Cable diagnostics function to help troubleshooting wiring problem including Optical Fiber Cable connecting network accessories. 147 Supply and fixing of POE 8 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection /EFT protection for power line. ( Make : DLINK, NETGEAR / TPLINK ). 148 Supply and Fixing of Rack with Accessories -Higher end 4 U Rack and fan extra for the above rack. 149 Supply and Fixing of Rack with Accessories -Higher end 12 U Rack with LNS unit and fan extra for the above rack. 150 Supply and fixing of 2 feet CCTV Camera Stand with attachment fittings as follows:* Weather heads and couplings* Cabinet mounting fittings, plates, brackets as needed.* Reinforced couplings for wire entrances to cabinets. 151 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 152 Supply and fixing of6mLengthpole with base plate of size 250x250x6mmasperIS-875withfollowingspecification.PoleOuterdie-76.10mmx 3.65mm Thick x 6 meter. Excavation, PCC, shuttering, reinforcement, Concretingfor fixing the post. The Rate is inclusive of curing with all necessary materials. (300x300x600). 153 PA System 154 Supply, Installation,Testing & commisioning of 30 watts 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. (Make:AhujaAMH402T/Bosch or its equivalent). 155 Supply, Installation,Testing & commisioning of 480 watts P.A Mixer Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.(Make:Ahuja SSA 10000/Bosch or its equivalent). 156 Supply, fixing & Testingof10 gooseneck with suitable base incorporates separate bush switches for momentary and dynamic microphone with 600ohm impedence and has 2.5mv/pa sensitivity and frequency response ranging from 50-15000hz with multi tone chime model.(Make:-ACM66 Ahuja/bosch/its equivalent). 157 Supply and run of 2core 1.5 Sqmm armoured speaker cablein suitable size of 38mm/50mm HDPEpipeinatrenchtobeexcavatedatadepthof0.75metreand refilling the earth to make good. 158 SAFETY SYSTEM 159 Supply of 2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS. Set (5 Nos). 160 Supply of First Aid Box complete with all First Aid Medicines. 161 Supply of Shock Treatment Chart fixed in glass frame. 162 Supply of Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
TenderDetail
Loading tenders