Tender For Provision Of Shed For Storage Of Ops Equipment Near 159 Hu At Af Stn Sonegaon, Nagpur -Excavation Over Areas In Soft / Loose Soil N. Exc. 1.50M Deep And Getting Out Complete All As Specified And Directed. 2 Excavation In Trenches In Soft / Loose Soil N. Exc. 1.50M Wide And N. Exc. 1.50M Deep For Foundation, Or For Shafts, Wells, Cesspits, Manholes, Etc., N. Exc. 10 Sqm On Plan Getting Out Complete All As Specified And Directed. 3 Removing Excavated Soilexceeding 1.5 Km And Not Exceeding 5 Km And Depositing Where Directed Complete All As Specified And Directed. 4 Returning, Filling In And Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm Thickcomplete All As Specified And Directed. 5 M&L For Moorum / Red Bajri Filling In Floors Or Pavings, Laid In Layers N Exc. 15 Cm Thick, Spread, Levelled And Rammed Including Watering Complete All As Specified And As Directed. 6 M&L For Hardcore Of Broken Stone Or Boulders Of Gauge Not Exceeding 63Mm, Deposited, Spred And Levelled In Layer Not Exceeding 15Cm Thick, Watered And Rammed To True Surface Complete All As Specified And As Directed. 7 M&L 75Mm Thick Pcc ( 1:3:6 ) Type C-1 Using 20Mm Graded Stone Aggregate As In Plinth Protection Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 8 M&L For Pcc 1:4:8, Type D2, Using 40Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete All As Specified And As Directed. 9 M&L For Providing Rcc ( 1:2:4 ) Type B-1 Using 20Mm Graded Stone Aggregate As In Foundations Including Rafts, Footings, Foundation Beams, Plinth Beams, Bases For Columns Etc., And Mass Concrete Complete All As Specified And Directed. 10 M&L For Providing Rcc ( 1:2:4 ) Type B-1 Using 20Mm Graded Stone Aggregate As In Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And Directed. 11 M&L For Pcc ( 1:2:4 ) Type B-1 Using 20Mm Graded Stone Aggregate As In Coping, Channels, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Etc. Complete All As Specified And Directed. 12 Use And Waste Of Formwork To Foundations, Fillings, Bases Of Columns, Rafts & Raft Beams, Sides & Soffits Of Foundation & Plinth Beams And Similar Works; Vertical Or Batter For Rough Finished Surface Of Concrete Complete All As Specified And As Directed. 13 Use And Waste Of Formwork To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions, Rough Finished Surface Of Concrete Square, Rectangular Or Polygonal Complete All As Specified And As Directed. 14 M&L For Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends & Binding With & Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And Directed. 15 M&L For Mild Steel Tmt Bars 5Mm Dia And Overup To And Including 10Mm Dia In Stirrups, Spacers And Binders Cut To Length, Bent To Shape Required And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips Quality Conforming To Fe-500D Complete All As Specified And As Directed. 16 M&L For Providing Precast Cement Concrete Solid Building Blocks Or Slabs 10Cm Thicktype B1 , 1:2:4 Using 20Mm Graded Aggregate ( With Plain Or Interlocking Joints As Directed ) Setting In Mortar 1:4 Complete For Drain Cover Completeall As Specified And As Directed. 17 M & L For Cement Concrete Work In Pavement / Hard-Standing Of Flexural Strength 40 Kg / Per Square Centimetre In Field Using400 Kg Of Cement Per Cubic Metre, Thickness Of Concrete 25 Cm Or Less Completeall As Specified And As Directed. 18 M&L For Providing Glass Dividing Strips, 3 Mm Thick And Width Of Strip 28Mm Inserted In Pcc Floor Completeall As Specified And As Directed. 19 S&F Steel Ventilator With Top Hung Shutter Including Hinges, Steel Peg Stay, Complete All As Specified And As Directed. 20 S&F Sheet Glass Ordinary Quality 3Mm Thick Quality With Oil Putty In Sequence Not Exceeding 0.5 Sqm In Each Pane Complete All As Specified And As Directed. 21 S&Fsteel Rolling Shutters With Thickness Of Laths 1.25 Mm, With Out Ball Bearing As Specified Including Top Cover, An Choring Rod, Hasp And Staple And One Shop Coat Of Primer; Erected In Position As Indicated, Complete: Push Pull Or Manual Type Complete All As Specified And Directed. 22 S&F Safety Lever Locks Mild Steel With 4 Levers For Rollingshutters Complete All As Specified And Directed. 23 S&Fframed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Beprepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings ( Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides ) Andhanging; Also Fastening And Fixing Complete Conforming To Fe 290 Gde-E-165 Complete All As Specified And Directed. 24 S&Fframed Work Such As Grills, Gratings Etc., With Ends Of Bars Shouldered And / Or Riveted Or Forged Into Spikes, Framed Guard Bars, Barred Iron Doors, Ladders, Framed Balusters, Walk Ways, Railings, Framework Of Water Tanks & Similar Work Conforming To Fe 290 Gde-E-165 Complete All As Specified And Directed. 25 M&L For Fe 410-W ( Gde-E- 250 ) Quality-A Roof Trusses ( Framed ) , Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing ( Beam, Tee, Angle, Channel Or Flat Sections ) Including Distance Pieces, Cleats Etc.Complete All As Specified And As Directed. 26 S&F Fe 410-W ( Gde-E- 250 ) Quality-Aplates ( Plain Or Chequered ) Channels, Square Cut Ornotched ( Ordinary And Counter Sunk ) Forming Holes, Without Any Attachmentcomplete All As Specified And Directed. 27 S&F 11Mm To 15Mm Diamild Steel Screw Bolts ( Machine Made ) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Not Exc 5Cm Long Complete All As Specified And Directed. 28 M &L For Preparation Newsteel And Iron Surfaces Not Otherwise Described Exc 10Cm Width Or Girthand Applying Two Coats Of Synthetic Enamel Paints Over One Coat Of Primer Of Red Oxide Complete All As Specified And As Directed. 29 S&F Pre-Painted Galvalume Aluminiun Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With J Hooks Including Self Tapping Screws And Self Drilling Screws Of Appropriate Size With Rubber Washer For Water Tight Fixing Complete All Asspecified And Directed. 30 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws Complete All Asspecified And Directed. 31 M&L For Rendering In Cement Mortar 15Mm Thick In Two Coats, I.E, In Cement Mortar 1:4, 5Mm Thick Mixed Withwater Proofing Compound As Per Manufacturers Instructions Over In Cement Mortar 1:6, 10Mm Thick On Fair Faces Of Brick / Concrete Surfaces, Finished Even And Fair Externally All As Specified And As Directed.Note:Wpc Will Be Measured And Paid Separately. 32 Supply Only Integral Water Proofing Compound 33 M&L Preparation Of Newly Plastered Surface Of Walls And Applying Two Coats Of Cement Base Paint Over A Coat Of Alkali Resistant Primer Complete All As Specified And Directed. 34 M&L For Surface Point Wiring Complete With 1.5Sqmm ( Nominal Area ) Pvc Insulated Unsheathed Multistranded, ( Two Runs For Phase And Neutral ) Copper Conductor Fr & Ls Grade Cable Of 1100V Grade Conforming To Is -694 Drawn Through And Including New Pvc Casing And Capping Of Size 25 X 16Mm Withaccessories Fixed On Surfaces Of Wall / Floor And Fixed On Ceiling / Roof Etc, Including Pressed Steel Terminal Boxes 1.6Mm Thick, Concealed In Walls With Plastic Laminated Sheet Cover 3Mm Thick As Top Coverfixed Withcadmium Plated Screws Forhousing The Switch Sockets, Outlets, Fan Regulator Etc Including Provn Of 1.5Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Of Green Colour For Earth Continuity And Connecting To Common Earth Dolly Complete All As Specified And Directed For:- 35 One Light / Fan Point Controlled By One Switch. 36 One 3 Pin Switch Socket Outlet, 5Amps On Independent Board Controlled By One Switch. 37 M & L For All As Per Item No.34 Here In Before But Point Wiring With 2.5 Sqmm Multistrandard Copper Cable For 5 Pin 15 Amp Switch Socket Combination On Independent Boardwith One Run Of 2.5 Sq Mm Multistranded Copper Cable Green Colour For Earth Continuity Conductor Complete All As Specified And Directed. 38 Supply And Fix Switch Piano, Flush Type, Single Pole, One Way, 5 Amps, 230 Volts All As Specified And Directed. 39 S&F Ceiling Rose Surface Backlite, 65X50mm, Three Terminals, 5 Amps, 240 Volts Ac Complete All As Specified And Directed. 40 Supply And Fix Switch Socket Combination 3 Pin, 6 Amps, Flush Type, 230 Volts All As Specified And Directed. 41 Supply And Fix Switch Socket Combination 2 In 1, 3 Pin, 6 And 16 Amp Flush Type Universal All As Specified And Directed. 42 Supply, Fix, Connecting And Testing Factory Made, Mcb Distribution Board ( Mcb Db ) , Ip 38, Spn, 8 Way, 240 Volts, Single Door, Flush Type Made Out Of 1.2Mm Thick Crca Sheet Metal, Phosphatised, Duly Powder Coated And Conforming To Is 13032 With 200 Amps Rated Bus Bar, Neutral Link, Earth Bar And Din Rail Etc. Complete Fixed In Switch Board / Wall Complete All As Specified And Directed. Note: Mcbs Shall Be Measured And Paid Separately. 43 Supply, Fix, Connecting And Testing Mcb Single Pole And Neutral ( Mcb Spn ) , 32Amps, 240 Volts Of Rupturing Capacity 10Ka, C Curve Typecomplete All As Specified And Directed. 44 Supply, Fix, Connecting And Testing Mcb Single Pole ( Mcb Sp ) , 6 To 32Amps, 240 Volts Of Rupturing Capacity 10Ka, C Curve Typecomplete All As Specified And Directed. 45 Supply And Fix Led Tube Light Fittingcapacity 20 Watt Fixed On Wall / Surface / Ceiling With All Accessories Tube, Driver, With Surge Protector Complete Wiredwith Multistranded Copper Cable & Connecting To Ceiling Rose With3 Core , Multistrandedflexible Copper Cable Complete All As Specified And Directed. Make Cg Cat Partno- Ldl-20-Nw Or Its Equivalent In Havells / Philips / Bajaj. 46 Supply And Fixing Ceiling Fans Complete With Blades, Down Rods, Electronic Regulator And Accessories, 230 V, 1200Mm Sweep. Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Ratedcomplete All As Specified And Directed. 47 Removal Of Excavated Materials To A Distance Notexceeding 50 Mtrsand Depositing Where Directed At A Level Not Exceeding 1.5 Mtr Above The Starting Point Complete All As Specified And Directed. 48 Supply, Lay / Spread In Trenches Clean Dry Sandto Required Width And Depth At Bottom And Top Of Cable Includingspreading, Levelling, Punning For Laying / Cushioning Of Cable All As Specified And As Directed.Note : Punned Thickness Only Will Be Considered For Payment. 49 Supplying And Laying Common Burnt Clay Sub Class ‘B’ Bricks Of Size 230 Mm X 115 Mm X 75 Mm, Laid Perpendicular To Axis Of Cable For Protection Of Lt Cables Complete All As Specified And Directed. 50 Supplying & Laying Gi Tubing 40 Mm Dia Light Grade Pipe With Connecting Acessories Complete In Trench For Road Andon Surface / , Wall For Protection Complete All As Specified And Directed. 51 M & Lfor Drilling Suitable Dia Horizontal Bore Holes For Insertion / Laying Of Gi Pipe Of Any Description Below / Under Road Surfaces / Floor Etc With Using Mechanical Or Manual Devices Including Making Good The Road With Necessaryreturning Filling And Bituminious Portion With Concrete And Bituminious Mixture And Cemented Portion With Pcc In 1:2:4 , 15 Cm Thick From Top And Matching The Surfaces With Existing Complete All As Specified And Directed. 52 Supply And Lay In Trenches / Drawn Through Pipes Or In Road Crossings / Paths / Drains / Ducts / Floors / Along Poles / Equipments Etc., Of Lt Cable Under Ground, Xlpe Insulated, Screened, Pvc Bedded, Galvanised Strip Or Wire Armoured, Heavy Duty Electric Cable With Stranded Aluminium Conductor, 1100 Volts Grade Of Cross Sectional Area 10 Sqmm 2 Core Including Connecting Up Using Suitable Size Aluminium Lugs Testing And Commissioning Complete All As Specified And As Directed. Note : Excavation Earth Work, Sand Cushioning And Brick Protection Shall Be Measured And Paid Separately.