Tender For Repair/Replacement Of Ac/Cgi Sheets, Roof Member And Coptic Roof Paint At Certain Otm Accommodation At Arc Charbatiaunder Ge (I)(Cg) Bhubaneswar, Cuttack-Odisha

Military Engineer Services-MES has published Tender For Repair/Replacement Of Ac/Cgi Sheets, Roof Member And Coptic Roof Paint At Certain Otm Accommodation At Arc Charbatiaunder Ge (I)(Cg) Bhubaneswar. Submission Date for this Tender is 29-11-2022. Paint Supply Tenders in Cuttack Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

34583255
Corrigendum : Tender For Repair/Replacement Of Ac/Cgi Sheets, Roof Member And Coptic Roof Paint At Certain Otm Accommodation At Arc Charbatiaunder Ge (I)(Cg) Bhubaneswar
Open Tender
Indian
Odisha
Cuttack
29-11-2022

Tender Details

Repair / Replacement Of Ac / Cgi Sheets, Roof Member And Coptic Roof Paint At Certain Otm Accommodation At Arc Charbatiaunder Ge ( I ) ( Cg ) Bhubaneswar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Nov-2022 Corrigendum No 1 Date 21-11-2022
2 14-Nov-2022 Corrigendum No 2 Date 25-11-2022
3 14-Nov-2022 Corrigendum No 2 BOQ 25-11-2022
4 18-Nov-2022 Corrigendum No 3 Date 29-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 91480.0 /-
Tender Value
INR 45.74 Lakhs /-

BOQ Items

Name of Work: REPAIR/REPLACEMENT OF AC/CGI SHEETS, ROOF MEMBER AND COPTIC ROOF PAINT AT CERTAIN OTM ACCOMMODATION AT ARC CHARBATIAUNDER GE (I)(CG) BHUBANESWAR
Sl. No. Item Description
1Dismantling of asbestos cement corrugated or semi corrugated sheet in roof covering complete all as specified and directed.
2Dismantling timber boarding, any description, fixed in any position with nails complete all as specified and directed.
3Dismantling of plain or corrugated steel sheeting any gauge any thickness incl nainital or similar pattern roof covering complete all as specified and directed.
4Dismantling of wall and ceiling boards (fibre pulp,insulation etc) or insulation boards/slabs any thickness incl cover fillets complete all as specified and directed.
5Demolition of brick or stone / boulders workbuilt in cement mortarincluding all quins, arches, pillars etc complete all as specified and directed.
6Dismantling of timber scantling 40 Sqcm and over in sec in any position as in framed work complete all as specified and directed.
7All as per item No-7 above here in before but under 40 sqcm in sec as inpurlins rafters fillets etc.
8M&L 4mm thick AC plain bldg board fixed with timber frame work as in ceiling surfaces complete all as specified and directed.
9M & L for Perforated particle board/tiles of thickness 12mm for insulation and acoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed.
10Supply and fix for anodized aluminium snap grid frame work with size of grid 605x605mm made out of aluminium ‘T’ section as main runner/ cross Tee and ‘L’ angle as wall angle for false ceiling including 4mmdia suspender, making position for light fittings, including provision of 6mm thick non asbestos fibre cement building, E-board (decorative) , fixed or laid/ inserted to timber/GI/ aluminium frame work with screw complete all as specified and directed.
11Material and labour for Providing and fixing suspended false ceiling, which includes providing and fixing GI ultra perimeter channels of size 0.55 mm thick having one flange of 20 mm and another flange of 30 mm and a web of 27 mm alongwith perimeter of ceiling, screw fixed to brickwall/partition with the help of nylon sleeves and screws, at 610 mm centres.then suspending GI ultra intermidieate channels of size 45 mm , 0.9 mm thick with two flanges of 15 mm each from the soffit at 1220 mm centres with ultra ceiling angle of width 25mmx10mmx0.55 mm thick fixed to soffit with GI cleat and steel expansion fasteners.Ultra ceiling section of 0.55 mm thickness having knurled web of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm are then fixed to the ultra intermidieate channel with the help of connecting clips and in direction perpendicular to the ultra intermidieate channel at 457 mm centres.12.5 mm tapered edge Gypboard (Confirming to IS-2095-1982) is then screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment.Finally the boards are to be jointed and finished so as to have a flush look which includes filling & finishing the tapered and square edges of the boards with jointing conmpound, paper tape and two coats of plastic emulson paint over 3mm thick putty complete all as specified and directed.
12S&F 6mm thick AC corugated sheet or semi corrugated sheet fixed with "L type or J type hooks in roof covering complete all as specified and directed.
13S&F 6mm thick Asbestos cement two-piece adjustable plain angular ridge complete all as specified and directed.
14S&F 0.63 mm CGI sheet with two corrugated inside lab fixed with "L" type hook as in roof complete all as specified and directed.
15S&F 0.63 mm Plain, galvanised, mild steel sheeting in ridges, hips valley gutters sun shed etc complete all as specified and directed.
16S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel steet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screwes complete all as specified and directed.
17S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed), fixed with self tapping screws complete all as specified and directed.
18M & L for Levering up edges of old plain or corrugated sheets (end or side) fixed to wood or steel framing, inserting end or side edge of new (sheet supplied by the M.D. for fixing only) and nailing, screwing, bolting or riveting including making good the joint between old and new sheets. (Not to be allowed for work measured as in patches) complete all as specified and directed.
19M&L brick work with sub class "B" bricks (old size bricks) straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed
20M&L for half thickbrick work with sub class "B" bricks straight or curved on plan exceeding 6m mean radius with old size bricks locaaly available built in cement mortar 1:4 complete all as specified and directed.
21Supply and fix20 mm thick, second class hard wood boarding,planed one sides with butt joints and fixed complete in position as in eaves board, etccomplete all as specified and directed.
22M & L 2nd class hardwood timber framed work clean sawn in scantling complete all as specified and directed.
23M & L 2nd class hard wood plain fillets square or rectangular in section clean sawn secured with nails or brads exc 3 & n exc 6 Sqcm complete all as specified and directed.
24S & F 2nd class HW plain fillets, square, rectangular, triangular in section exc 6 cm but n exc 13 Sqcm clean sawn secured fixed with nail complete all as specified and directed.
25M & L 2nd class hard wood plain fillets square or rectangular in section clean sawn secured with nails or brads but sec area exc 13 Sqcm but n exc 25 Sqcm complete all as specified and directed.
26Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
27S & F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc.Fe-410-W(Gde-E-250) quality-B complete all as specified and directed.
28S & F for wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
29M&L for prepraration of new surfaces of steel /iron of any description priming with red oxide primer exc 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
30M&L for prepraration of old decorated surfaces of steel /iron of any description (Plain or corrugated) exc 10 cm width or girth and applying one coat of aluminium paint at hanger wall and roof (Internal) complete all as specified and directed.
31M&L for Preparation of old painted surfaces of steel/iron of any description (plain or corrugated ) over 10 cm width or girth in roof and wall cladding and applying one coat (finishing coat) of coptic roof paint jenson & Nicholson product) all as specified and directed.
32Material and labour forpreparation of previously untreated surfaces of asbestos sheets of any description (plain or corrugated) over 10 cm width or girth in roof and wall cladding by removing all loose dirt, algi, fungus etcand applying Two coats of anti-fungus exterior emulsion paint (weather coat) complete all as specified and directed.
33Material and labour for preparing surfaces of wood and wood based materials, new of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
34M & L two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces incl preparation of new wooden surfaces complete all as specified and directed.
35M & L two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces incl preparation of new wooden surfaces of any description n exc 10 cm width or girth complete all as specified and directed.
36Taking down cement plaster on brick walls/ concrete surface, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
37Material and labour for rendering 15 mm thick in two layers (10mm + 5mm) externally on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished the surface even & smooth without using extra cement mixed withand excluding water proofing compound @ 2% on top layer of 5mm thick complete all as specified and directed. ( Note : Water proofing compound will measured and paid for separately).
38M&L 10 mm thick cement plaster in CM (1:6) on fair faces of brick work incl finished even and smooth without using extra cement complete all as specified and directed.
39Supply only integral water proofing compound complete all as specified and directed.
40M&L for Preparation of new plastered surfaces andapplying three coat of white wash on wall complete all as specified and directed.
41M&L preparation new plastered surfaces of brick work or previously un treated and applying two coats of oil bound distemper over wall care putty complete all as specified and directed.
42Hackingout broken glasses (any thickness ; size or design portion ) from wooden /metal frame complete all as specified and directed.
43supply and fix 3 mm thick ordinary quality sheet glass with oil putty or beadings supplied with joinery in square n exc 0.5 sqm in each complete all as specified and directed.
44S&F in reapairstainless steel wire mesh of 0.36 mm dia and average width of aperture 1.4 mm dia fixed with stainless steel wire staples and necessary welding work complete all as specified and directed.
45Taking down 15 mm bore GI tubing or up steeltubing and connection including cleaning for re-fixing complete all as specified and directed.
46Taking down 20 mm bore GI tubing or up steeltubing and connection including cleaning for re-fixing complete all as specified and directed.
47S&F 15 mm bore GI pipe tubes medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floor complete all as specified and directed.
48S&F 20 mm bore GI pipe tubes medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floor complete all as specified and directed.
49Cutting chases, pinning in making good to facings brick wall where required and pointing in cement mortar 1:3 to ends or edges of landings steps cills chases for concealed water tubing, exc 10 cm but not exc 20 cm girth complete all as specified and directed.
50Taking down eaves gutters and rainwater pipes (any size or pattern) , including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
51S & F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
52S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
53S & F 75 mm bore PVC (SWR) bends any radius complete all as specified complete all as specified and directed.
54S & F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
55S & F 75 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed.
56S & F 110 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed.
57S & F 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
58S & F 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
59S & F 110 mm bore PVC (SWR) reducers complete all as specified and directed.
60Demolition of cement concrete (unreinforced) as in padding layers of Roofs, floors (other than ground floors), and similar suspended work complete all as specified and directed.
61M&L cement concrete type B0 1:2:4 (12.5 mm graded aggregate) as in padding on existing roof surfaces & roof kerbs , rounded or chamfered on edges complete all as specified and directed.
62Material and Labour for rendering 15 mm thick with CM (1:4) on concrete surface including WPC, roof finished even and smooth without using extra cement over neat cement slurry @ 3 Kg /Sqm complete all as specified and directed. (Note : WPC measured and paid separately)
63Material and Labour for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, and filling solidly with a hot mixture of bitumen and clean dry and 1:1 ( by weight) complete all as specified and directed.
64Material and labour for providing water proofing treatment with a layer of APP based polymeric membrane, 3mm thick (minimum), weighing 3.50 Kg/Sqm reinforced with polyster non woven fabric (weighing not less than 160 gm/Sqm) shall be applied over one coat of cold bituminous primer @ 0.25 lit/Sqmcomplete all as specified and directed. (Note : The overlaps shall be of minimum 75mm on longitudinal direction and 100mm on transverse direction)
65M & L for Bitumastic gola, with 80/25 bitumen and coarse and mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed.
66Disconnecting existing tanks exc 250 Ltrs n exc 500 Ltrs setting aside (for lowering if required) for repairs, cleaning, etc and hoisting if required reconnectingnand refixing in position complete all as specified and directed. (Note : Cleaning repairing, etc measured separately)
67All as per item No 66 above but exc 500 Ltrs n exe 1000 Ltrs
68S&F In repair 1000 Ltr capacity rotational moulded polyethyene water storage tanks (Cylindrical vertical with closed tap) twisted and fixed in position all as specified in SSR Part-I complete all as specified and directed. (Make : Sintex/ Polycon ISI marked)).
69S&F In repair 500 Ltr capacity rotational moulded polyethyene water storage tanks (Cylindrical vertical with closed tap) twisted and fixed in position all as specified in SSR Part-I complete all as specified and directed. (Make : SintexPolycon ISI marked).
70Taking down steel hangar gate carefully from the existing position and refixing after repair works including necessary welding and nut bolts and proper greasing etc the same for smooth and easy pulling and pushing includingproper cleaning, greasing the floor and the top channel, making good and cleaning of disturbed surfaces complete all as specified and directed. (Note : Approx size of gate 25.00 m x 8.00 m)
71Taking down steel rolling shutter carefully from the existing position and repairingthe same for smooth and easy pulling and pushing after proper oiling, greasing, replacing MS shaft pipe and steel oil (helical wire spring), ball bearing repairing locking bracket plates, including necessary welding etc andrefixing the same in position, making good and cleaning of disturbed surfaces complete all as specified and directed. (Note : Approx area of per rolling shutter 6.00 Sqm to 11.50 Sqm)
Disclaimer :