BRR : 9500369
Tender Brief : Tender For Work Of Overhauling Of Valves And Wall Blowers Of Unit No. 13, 2×200 Mw, Btps, Obra - Servicing of Feed line and Steam line gate valves & control valves viz.V2-116,V2-117,V2-85,V2-86, FCV-1&7, V2-56 (L&R) and E2 etc. 2 Servicing of E-2 NRV (Nb-300mm, Np-250 Kg/cm2). 3 Servicing of Low Load line gate valves and Control Valve (FCV-2) 4 Servicing of pneumatically operated S/H spray valve (E-19). Valve size Nb150mm, NP-250Kg/cm2. 5 Servicing of pneumatically operated R/H spray (R-17) valve. 6 Servicing of pneumatically operated S/H & R/H spray control & isolating valves. 7 Servic... Read More
Tender Value
₹
7,33,986
Submission Date
06-10-2025
Participated Bidder List
2 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics |
Work Detail
tender for work of overhauling of valves and wall blowers of unit no. 13, 2×200 mw, btps, obra - servicing of feed line and steam line gate valves & control valves viz.v2-116,v2-117,v2-85,v2-86, fcv-1&7, v2-56 (l&r) and e2 etc. 2 servicing of e-2 nrv (nb-300mm, np-250 kg/cm2). 3 servicing of low load line gate valves and control valve (fcv-2) 4 servicing of pneumatically operated s/h spray valve (e-19). valve size nb150mm, np-250kg/cm2. 5 servicing of pneumatically operated r/h spray (r-17) valve. 6 servicing of pneumatically operated s/h & r/h spray control & isolating valves. 7 servicing of boiler drum safety valves at 52m elevation 8 servicing of safety valves installed on hot reheat, cold reheat line and main steam line on right hand side of boiler at 52m elevation. 9 servicing of safety valve on soot blower line at 52m elevation. 10 servicing of high-pressure valve & nrv’s at different elevation from ‘0’meter level to 54meter level nominal bore may vary from ø10mm to ø100mm. 11 servicing of l.p. valves of air line, oil line & water line. 12 servicing of electromagnetic relief valve 13 servicing of h.o. filter 14 replacement/servicing of the actuators of v2-116 & 117, v2-85 & 86, v2-56 (l&r), e-2 valves 15 replacement/servicing of the actuators of b-55, s-16 and soot blower isolating valve size 65 mm 16 replacement/ dismantling and re-fitting of valves of size - 15 mm to 25 mm 17 replacement/ dismantling and re-fitting of valves of size - 40 mm to 50 mm 18 replacement/ dismantling and re-fitting of valves of size - 65 mm to 70 mm 19 replacement/ dismantling and re-fitting of valves of size - 100 mm valves 20 replacement/ dismantling and re-fitting of valves of size - 150 mm to 200 mm 21 replacement/ dismantling and re-fitting of various safety valves of such as boiler drum/ main steam/ crh/ hrh line etc. 22 welding of main steam line joint by tig welding. 23 repairing of main steam line joint. 24 welding of cold reheat / hot reheat line. 25 servicing of wall blowers 26 servicing of head valve of wall blowers 27 repairing/replacement of worn out pipes and bends of atomizing steam, heavy oil line/water line/air line from 15mm to 40mm nb from old & used healthy economizer pipe dia 32mm/new tracing line of 32mm/40mm. new tracing line pipe/ old economizer tubes
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Technical Evaluation In Progress
Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.
TechnicalBid
Similar Tenders Results