BRR : 9218508
Tender Brief : Overhauling / Servicing Of H.P. Valves And Actuators Including Replacement Of H.P. Drip / Drain Line Pipes Of Unit-Ii Of 3X210 M.W., Atps, Anpara- 1 Servicing Of Feed Line Gate / Control Valves / Nrv Size Nb- 300Mm Np-250 Kg. / Cm² 2 Servicing Of Low Load Line Gate & Control Valves Size Nb- 200Mm Np-250Kg / Cm² 3 Servicing Of Pneumatically Operated S / H, R / H Attemperation Control Valves & Rh Spray Block Valves. 4 Servicing Of Main Isolating Valve Bf-61 At The Inlet Of Sh Spray Station, Size: Nb- 150Mm, Np-250Kg / Cm² 5 Servicing Of Main Isolating Valve Of Ma... Read More
Tender Value
₹
10,57,129
Submission Date
10-11-2022
Participated Bidder List
4 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics | |||||
| 3 | cnet-technologies | Bid Analytics | |||||
| 4 | cnet-technologies | Bid Analytics |
Work Detail
overhauling / servicing of h.p. valves and actuators including replacement of h.p. drip / drain line pipes of unit-ii of 3x210 m.w., atps, anpara- 1 servicing of feed line gate / control valves / nrv size nb- 300mm np-250 kg. / cm² 2 servicing of low load line gate & control valves size nb- 200mm np-250kg / cm² 3 servicing of pneumatically operated s / h, r / h attemperation control valves & rh spray block valves. 4 servicing of main isolating valve bf-61 at the inlet of sh spray station, size: nb- 150mm, np-250kg / cm² 5 servicing of main isolating valve of main steam line ( l&r ) m.s.-29 & m.s.-30, nb-350mm, np-250kg / cm² 6 servicing bypass valves of main steam valves –ms-29a, and ms-30a, nb-25mm, np-250kg / cm² 7 servicing of bypass valves of feed station, low load line valve and main isolation valve of inlet to sh-nb-25mm, np-250kg / cm². 8 servicing of boiler drum safety valves and safety valve on main steam line on right hand side of boiler at 52meter elevation. 9 servicing of electromagnetic relief valve ( implies safety valve ) .maximum working parameters:-pr.-160.0kg / cm², temp.540ºc size-2½” / 2” / 4”. 10 servicing of safety valves installed on hot reheat and cold reheat line at about 50meter elevation.maximum working parameters:-i ) crh sv ( r-5 ) pr.-45kg / cm², temp. -345 ºc, size- 6”&8”.ii ) crh –sv ( r-6 ) pr.46kg / cm², temp. . -345 ºc, size 6”&8”.iii ) crh –sv ( r-11 ) pr.45kg / cm², temp.-345 ºc, size 6”&8”.iv ) hrh –sv ( r-20 ) pr.42.5kg / cm², temp.-540 ºc, size 6”&8”. 11 servicing of safety valve on soot blower line at 52mtr elevation.maximum working parameters:-sr –sv ( se-7 ) pr.42kg / cm², temp.-360 ºc, size-2½” / 2½” 12 servicing of high-pressure valve & nrv’s at different elevation from ‘0’meter level to 54meter level nominal bore may vary from ø10mm to ø100mm. 13 replacement of h.p. valves of sizes-nb-10 / 15 / 25mm ( h / o ) at different floors from ‘0’meter level to 54meter level and at dearator floor by cutting of damaged valve and welding of new valve after its revisioning. 14 servicing / replacement of hydra motor valves of oil station at ab / cd / ef elevation. 15 servicing of oil line valves and nrv’s of oil station at ab / cd / ef elevation of boiler. 16 servicing / overhauling of pneumatic operated dia150mm / dia 250mm valves on aux. prds line and deaerator. 17 servicing / overhauling of electrically drive steam valve dia 100mm to 250mm on aux. prds line. 18 servicing / overhauling of electrically driven nb- 400mm gate valve at dearator. 19 servicing / overhauling of electrically drove nb- 50mm valves on aux. prds line. 20 servicing / overhauling of pneumatic operated control valve size 50 to 100mm 21 servicing / overhauling of hand operated valve / nrv’s of size 150 to 250mm. 22 servicing / overhauling of hand operated valves / nrv’s of size 300mm and above. 23 servicing and revisioning of steam valves & nrv’s of aux. prds line and dearator. 24 changing flange gaskets of valves & flange at different elevation of boiler. 25 replacement of gland packing with new one from valves leaking from glands. 26 attending leakages of pipeline& headers etc. of main boiler, dearator and aux. prds of 3x210 mw by cutting grinding and h.p. welding of damaged portion putting new spools / bends if required.note: -rates should be quoted on the basis of per cm / per cm thickness of welded seen, which should be inclusive of cutting, grinding, putting new spools / bends if required and h.p. welding. 27 servicing / overhauling of pneumatically operated actuators of valve. size dia 40 to 100mm. 28 servicing / overhauling of pneumatically operated actuators of valves size dia 200 to 300mm 29 fabrication of h.p. drip line bends out available pipe by cutting, grinding & h.p. welding. 30 servicing / overhauling of safety valve of aux. prds 31 servicing / overhauling of safety valves of dearator. 32 blanking of hot reheat and cold reheat nrv by blanking device & normalizing the same. 33 replacement of h.p. valves / nrv of 100 mm valve / nrv at dearator floor by cutting and welding with new / repaired valve / nrv after its revision 34 replacement of h.p. valves / nrv of 150 mm valve / nrv at dearator floor by cutting and welding with new / repaired valve / nrv after its revision 35 replacement of h.p. valves / nrv of 200 mm valve / nrv at dearator floor by cutting and welding with new / repaired valve / nrv after its revision 36 replacement of h.p. valves / nrv of 250 mm valve / nrv at dearator floor by cutting and welding with new / repaired valve / nrv after its revision 37 replacement of h.p.valve / nrv of 200 to 350 mm sizes at dearator floor of flange end type by opening nut and bolts of flange and installation of new / repaired valves / nrv on it properly after replacement of gasket 38 replacement of start up vents ( r / h & s / h ) , at 54-mtr elevation. 39 replacement of high pressure valves ( motor operated / pneumatic operated / hand operated ) of critical piping of boiler of size: nb-40mm to 65mm 40 replacement of pneumatic actuators of valve size up to nb-300mm at different elevations. 41 replacement of h.p. drain pipes of size nb-200mm, thickness- 6mm, material- carbon steel per joint 42 replacement of h.p. drain pipes of size nb-150mm, thickness- 8mm, material- carbon steel per joint 43 optional work 44 replacement of various safety valves of critical piping such as boiler drum, super heater, crh, hrhetc . 45 replacement of 150mm prds control valve 46 replacement of 100mm prds control valve
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Technical Evaluation In Progress
Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.
TechnicalBid
Similar Tenders Results