BRR : 7602020
Click Here To View Tendering Authority. Aoc City/State :  anpara, Uttar Pradesh
Tender Brief : Tender For Overhauling Of Soot Blowers & Valves Of U7--- 1 Servicing / Revisioning of Boiler Circulation Pump Elbow down stop check valve, Nb – 350/300 mm, Design Pr. – 213.8 Kg/sq.cm 2 Servicing /Revisioning of Main steam stop Valve (MSV-1&2). Nb - 500 mm, Design Pr. - 191.5 Kg/ sq.cm. 3 Servicing/ Revisioning of Economizer Inlet Isolating gate Valve. Nb - 450 mm, Design Pr. - 320 Kg/ sq.cm. 4 Servicing/ Revisioning of Economizer non return flap Valve. Nb - 450 mm, Design Pr. - 320 Kg/ sq. cm. 5 Servicing/ Revisioning of SH Spray outlet Isolating valves. Nb -125 mm, Np - 356 Kg/ sq.cm. ... Read More
Tender Value
Ref. Document
Contract Value
₹ 11,01,769
Submission Date
08-05-2024
Contract Date
29-07-2024
Completion Date
25 days
Participated Bidder List
4 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 10,30,648 L2
2 cnet-technologies Bid Analytics 12,04,359 L4
3 cnet-technologies Bid Analytics 10,16,060 L1
4 cnet-technologies Bid Analytics 10,48,380 L3
Work Detail
tender for overhauling of soot blowers & valves of u7--- 1 servicing / revisioning of boiler circulation pump elbow down stop check valve, nb – 350/300 mm, design pr. – 213.8 kg/sq.cm 2 servicing /revisioning of main steam stop valve (msv-1&2). nb - 500 mm, design pr. - 191.5 kg/ sq.cm. 3 servicing/ revisioning of economizer inlet isolating gate valve. nb - 450 mm, design pr. - 320 kg/ sq.cm. 4 servicing/ revisioning of economizer non return flap valve. nb - 450 mm, design pr. - 320 kg/ sq. cm. 5 servicing/ revisioning of sh spray outlet isolating valves. nb -125 mm, np - 356 kg/ sq.cm. 6 servicing/ revisioning of pneumatically operatedblockvalve & control valve of super heater attemparation line. nb – 100 to 150 mm, design pr. –356 kg/ sq.cm. 7 servicing/ revisioning of pneumatically operatedblockvalve & control valve ofreheater attemparation line.nb – 65 to 100 mm, design pr. – 176 kg/ sq.cm. 8 servicing/ revisioning of rh spray outlet isolating valves. nb -65 mm, np - 176 kg/ sq.cm. 9 servicing/ revisioning of soot blowing prv and other similar valve . nb 50 to 100 mm, np – 198.9 kg/ sq.cm 10 servicing/ revisioning of high pressure hand operated valves and nrvs . nb – 10 to 200 mm. 11 servicing/ revisioning of motor operated high pressure valves. nb -20 to 200 mm. 12 servicing/ revisioning of blow down valve motor operated valves .nb – 40 mm , design pr.-210.8 kg/cm2. 13 blanking of hot reheat and cold reheat isolating device( dia. 660 mm) by blanking device and normalising the same. 14 servicing/ revisioning of boiler drum safety valves. nb – 3”/6”, design pr.- 209 to 216 kg/ sq. cm. 15 servicing/ revisioning of ms line safety valves. nb – 3”/6”, np - 185.5 kg/ sq. cm. 16 servicing/ revisioning of ms line electromatic relief valves. nb – 2.5”/4”, np – 185 to 187 kg/ sq. cm. temp. - 540 deg. c 17 servicing/ revisioning of hot re-heat & cold re-heat safetyvalves. (a) crh - nb -6”/10”, design pr – 52.4 to 54 kg/ sq. cm. (b) hrh – nb -6”/8”, design pr – 49 to 50.5 kg/ sq. cm. 18 servicing/ revisioning of hot re-heat electromatic relief valves. nb – 6”/8”, np – 48 to 48.5 kg/ sq. cm. temp. - 540 deg. c 19 servicing/ revisioning of soot blower prv outlet safety valves. nb – 2.5”/4”, np - 40 kg/sq. cm. 20 servicing/ revisioning of heavy & lightoil valves (pneumatic operated ) as hotv, lotv,hocv,locv,hortv,lortv nb –40-100 mm, working pr. -15/ 22 kg/sq. cm. 21 replacement of gaskets of flanges and bonnets of valves. 22 replacement of gland packing of high pressure valves. 23 attending leakage of pipelines and headers etc. of main boiler 24 cleaning of oil strainer of fuel oil station on firing floor. 25 replacement of high pressure valve (motor operated/hand operated) of critical piping of boiler of size 15 - 25 mm. 26 replacement of high pressure valve (motor operated/hand operated) of critical piping of boiler of size 40 - 50 mm. 27 replacement of high pressure valve (motor operated) hand operated) of critical piping such as main steam, final super heater, primary super heater, cbd etc. of size 65 - 150 28 overhauling of lrsb 29 overhauling of wall blower 30 overhauling of carriage house assembly . 31 overhauling of soot blower steam head valve.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 16010e94-5576-4bdd-87b3-ea0fefcaaa34
Download boqcomparativechart
Download finsummary_1591717
Download techsummary_1591717
Download valve
Download File Name File Description
Download 88d02441-73aa-410d-8dc4-2abdfb14c486 Tender Documents
Download BOQ_1591717 Tender Documents
Download tdoc Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders