BRR : 8466608
Tender Brief : Supply And Installation Of Laboratory Equipments (Set-1) As Per Specification , Uv-Vis Spectro Photometer - Optical Design: -Double Beam - Spectral Bandwidth: - 2 Nm - Light Source :-(Typical Lifetime >5 Yrs) Xenon Flash Lamp (3 Years Guaranteed) - Detectors: -Dual Silicon Photodiodes - Wavelength Range: - 190–1100 Nm - Wavelength Accuracy: - ±0.5 Nm - Wavelength Repeatability: - <±0.2 Nm - Scan Speed:- Slow, Medium And Fast (Up To 1600 Nm/Min) - Photometric Linear Range –2A To +3.5A - Photometric Accuracy:- ±0.002A At 0.5A ,±0.004 A At 1.0 A, ±0.008A At 2.0A - Photometricrepeatability :-± 0.... Read More
Tender Value
₹
Ref. Document
Contract Value
₹ 14,45,500
Submission Date
27-10-2025
Contract Date
20-12-2025
Completion Date
42 days
Participated Bidder List
5 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 8,66,250 | L1 | |||
| 2 | cnet-technologies | Bid Analytics | 14,45,500 | L1 | |||
| 3 | cnet-technologies | Bid Analytics | 16,00,000 | L4 | |||
| 4 | cnet-technologies | Bid Analytics | 15,05,680 | L3 | |||
| 5 | cnet-technologies | Bid Analytics | 17,55,518.18 | L5 |
Work Detail
supply and installation of laboratory equipments (set-1) as per specification , uv-vis spectro photometer - optical design: -double beam - spectral bandwidth: - 2 nm - light source :-(typical lifetime >5 yrs) xenon flash lamp (3 years guaranteed) - detectors: -dual silicon photodiodes - wavelength range: - 190–1100 nm - wavelength accuracy: - ±0.5 nm - wavelength repeatability: - <±0.2 nm - scan speed:- slow, medium and fast (up to 1600 nm/min) - photometric linear range –2a to +3.5a - photometric accuracy:- ±0.002a at 0.5a ,±0.004 a at 1.0 a, ±0.008a at 2.0a - photometricrepeatability :-± 0.001a at 1a - photometric noise :- <0.00020a at 0.0 a; <0.00030 a at 1.0 a; <0.00040 at 2.0 a - photometric drift :- <0.0005 a/hr - stray light :- < 1.0%t 198 nm (kcl) , <0.05%t at 220 nm (nai), <0.03%t at 340 nm (nano2) - baseline flatness: - ±0.002a - 8-position cell changer - display 7-inch color touchscreen, tiltable, high definition, 800 × 1280 pixels. - warranty 3 years standard & additional 2 years amc - ce certificate & iso certificate should be provided. , pcr thermal cycler - sample capacity: the system to be capable to use 96 well pcr plates / 8 x 12 pcr strips /96 x 0.2ml tubes. - the system should be a 96 well thermal cycler with 3 separate peltier blocks to provide independent temperature zones to run – six different assays with varying annealing temperatures at the same time. - sample volumes: the system should support volumes ranging from 10 – 100 ?l / tube. - thermal optimizations: the system to have minimum 3 temperatures to set for the pcr optimization. run upto 3 separate temperatures in one run to determine optimal annealing temperature and system should maintain thermal characteristics between optimization and isothermal condition to eliminate further optimizations. - each peltier block to have the ability to set up pcr with a specific temperature differential of up to 10 °c. - programmable heat cover: heated lid should be programmable between 50 to 110°c to perform oil free pcr. - the system should have a ramp rate of minimum 3.50°c/sec. - the system should have a sample ramp rate of minimum 2.70°c/sec - the system to support temperature range starting from 0°c – 100°c. - the system to have a * temperature accuracy ± 0.25 °c at 35°c – 99.9°c. * temperature uniformity < 0.5°c 20 sec’s after reaching 95°c. - programming: the system to have in built minimum 5-inch color tft lcd with touch screen programming panel, allowing for easy intuitive graphical user interface. the instrument to support mouse or stylus free programming & navigation capability. - memory: the system to have provision to save protocols more than 800 in the instrument. system to be open to expansion of memory via usb memory stick. the system should allow easy product / software updates via usb port. - security: the system to have provision to create separate user profiles protected by passwords. - portability: the system should have a usb port to transfer methods from one machine to another with option of cloud/wifi connectivity. - warranty: the system should have a warranty period of 3 years and amc 2 years , elisa microplate reader multiskantm fc microplate photometer specifications: * compatibility - robot * detector type - photodetector * interface - on-board or pc control * light source - quartz halogen lamp * measurement speed -7 s for 96-well plate (fast mode), 13 s for 96-well plate (normal mode) * measurement technology - absorbance * plate type - 96-well plate
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results