BRR : 2221751
Click Here To View Tendering Authority. Aoc City/State :  dibrugarh, Assam
Tender Brief : Equipments For The Icmr Ner Task Force New Scheme Entitled Advanced Mycology Diagnostic And Research Centre Equipments For The Icmr Ner Task Force New Scheme Entitled Advanced Mycology Diagnostic And Research Centre , Items : , Real-Time Pcr Specifications: An Automated System For Both Pcr And Post-Pcr End-Point Analysis, Using In-Built Peltier Based Pcr Machine; The System Should Support Applications Including Absolute And Relative Quantification, Multiplex Pcr Allelic Discrimination, Melt Curve Analysis, Pathogen Detection And Plus/ Minus Assays Using An Internal Positive Control; Peltier T... Read More
Tender Value
Ref. Document
Contract Value
₹ 13,27,500
Submission Date
14-02-2022
Contract Date
02-03-2022
Completion Date
45 days
Participated Bidder List
4 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 13,27,500 L1
2 cnet-technologies Bid Analytics 3,06,800 L3
3 cnet-technologies Bid Analytics 2,36,000 L2
4 cnet-technologies Bid Analytics
Work Detail
equipments for the icmr ner task force new scheme entitled advanced mycology diagnostic and research centre equipments for the icmr ner task force new scheme entitled advanced mycology diagnostic and research centre , items : , real-time pcr specifications: an automated system for both pcr and post-pcr end-point analysis, using in-built peltier based pcr machine; the system should support applications including absolute and relative quantification, multiplex pcr allelic discrimination, melt curve analysis, pathogen detection and plus/ minus assays using an internal positive control; peltier thermal cycling for fast-pcr as well as standard-pcr run available in the same block. 40 cycles in less than 30 minutes; the system should have temperature range of 3-99 degrees c with maximum ramp rate of at least 5°c /second; should have a reaction volume of at least 50 ?l; the system should support micro well plates, individual tubes and 8-tube strips; the system should provide touch screen lcd feature to avoid dependency on computer for operation; should also be possible to use a computer for system control, operation, analysis and networking of multiple system; instrument should be supplied with a separate desktopalong with a standalone backup system capable of providing at least 90 minutes of backup time; usb port for data export to power point, excel or jpeg formats should be present; it should be an open system to use reagents from any manufacturer; system should be calibrated for common dyes of broader wavelength excitation and emission spectrum; excitation light source –laser / led; change of position, block or chemistry should not require calibration or tools; the system should be capable of operating at ambient temperatures of 20-30 degrees c; temperature gradient function should be available in the system; temperature uniformity should be ± 0.15°c & control accuracy ± 0.1°c; temperature increments should be min. of 0.1 °c/cycle & time increments should be min. 1 s/cycle; it should have at least 5 chanel multiplexingcapability in a single tube; instrument should not require the use of a reference dye such as rox and do not need regular calibration; instrument should use an advanced optical system; it should do scanning just above the sample & should guarantees the homogeneous excitation of each individual sample and the reliable recording of the emitted fluorescent signals with high sensitivity and no crosstalk between wells. should be european ce approved. should have a warranty period of at least 3 years and should include on-site installation and training. , minus 20°c deep freezer specifications: the deep freezer should have atleast 250 ltrs of capacity; should have temperature control system with microprocessor pid control; control of temperature within 3 °c of set temperature; doors should have triple gasket system to prevent any leakage; doors should have polyurethane insulation; should have audio alarm system, in case of i) high and low temperature ii) open doors iii) power failure; should provide onsite installation & training; should have at least 3 years warranty
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download afb7ea2b-bd27-4a59-984c-3a34a2547f6f
Download File Name File Description
Download 88bb380b-b2f1-4055-aad6-043b0b3c318b Tender Documents
Download BOQ_37262 Tender Documents
Download Tendernotice_1 Tender Documents
Download terms Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000