BRR : 4765726
Click Here To View Tendering Authority. Aoc City/State :  Bareilly, Uttar Pradesh
Tender Brief : The Work Of Maintenance Of Various Equipment’S At 33 Kv Control Panel / Vcb / Line Isolator Including Retro Fitting Of Damaged Protection Relayand Maintenance & Repair Work Of 11 Kv Vcb Etc. In Different 33 / 11 Kv S / S Undereudd-I, Bareilly For System Strengthening For Providing Uninterrupted 24*7 Power Supply Under The Head Of ( Additional B.P. 2023-2024 ) .-The Work Of Safe Carriage Of The Following Material From Cb Ganj Store Center To Work Siteunder The Jurisdiction Of Eudd-I Bareilly Approx. Distance Upto 30 Km. Including Safe Loading And Unloading. 2 11 ... Read More
Tender Value
60,00,000
Contract Value
₹ 54,07,800
Saving / Difference
₹ 5,92,200 ▲
Submission Date
11-10-2023
Contract Date
24-01-2024
Completion Date
365 days
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 54,07,800 L1
2 cnet-technologies Bid Analytics 70,73,750 L2
3 cnet-technologies Bid Analytics
Work Detail
the work of maintenance of various equipment’s at 33 kv control panel / vcb / line isolator including retro fitting of damaged protection relayand maintenance & repair work of 11 kv vcb etc. in different 33 / 11 kv s / s undereudd-i, bareilly for system strengthening for providing uninterrupted 24*7 power supply under the head of ( additional b.p. 2023-2024 ) .-the work of safe carriage of the following material from cb ganj store center to work siteunder the jurisdiction of eudd-i bareilly approx. distance upto 30 km. including safe loading and unloading. 2 11 kv current transformer 800 / 400 / 5 3 11 kv current transformer 400 / 200 / 5 4 11 kv current transformer 600 / 300 / 5 5 11 kv potentialtransformer 6 11 kv cat-a energymeter 7 11 kv panelo / c + e / f idmt relay with retrofitting arrangement 8 11 kv panel master relay with retrofitting arrangement 9 erection work 10 replacement of defective 11 kv current transformer 800 / 400 / 5 11 replacement of defective 11 kv current transformer 400 / 200 / 5 12 replacement of defective 11 kv current transformer 600 / 300 / 5 13 replacement of defective 11 kv current transformer 300 / 150 / 5 14 replacement of defective 11 kv potentialtransformer 15 replacementof defective 11 kv panelo / c + e / f idmt relay with retrofitting arrangement 16 replacement of defective 11 kv panel master relay with retrofitting arrangement 17 replacement & supply of defective ht hrc fuse for pt of appropriate rating 18 replacement & supply of defective hrc fuse of different rating 19 servicing and repairing of mechanical system for proper opening, closing & tripping of 11 kv breaker 20 replacement and supply of vcb charging motor of appropriate rating 21 replacement and supply of defective / burnt mcb of appropriate rating 22 replacement and supply of defective / burnt auxillary switch of appropriate rating 23 replacement and supply of defective antipumping relay 24 replacement and supply of defective spout 25 replacement and supply of defective busbar as per requirement / drawing 26 replacement and supply of defective jaw for 11 kv vcb trolley 27 replacement& supply of defective indicator 28 replacment & supply of defective ampere meter 29 replacment & supply of defective volt meter 30 replacment & supply of defective tnc switch 31 replacment & supply of defective local / remote switch 32 replacment & supply of defective buzzer 33 replacement & supply ofdefectiveclosing coil ( 24 v d.c ) 34 replacement & supply ofdefectivetripping coil ( 24 v d.c ) 35 replacement & supply of defectivevaccum interruptor 36 replacement & supply of defective tnc switch 37 servcing and repairing of electrical system for proper metering, opening, closing & tripping of 11 kv breaker including providing of necessary internal wiring, lugs, ferrules of appropriate rating and colour coding and other necessary accessories. 38 the work of safe carriage of the following material from cb ganj store center to work siteunder the jurisdiction of eudd-i bareilly approx. distance upto 30 km. including safe loading and unloading. 39 33 kv o / d vcb 1250 a 40 acsr dog conductor 41 new 33 kv control panel for double t / f 42 line isolator 800a 43 33 kv current transformer 400 / 200 / 1 44 33 kv panelo / c + e / f idmt relay with retrofitting arrangement 45 33 kv panel master relay with retrofitting arrangement 46 33 kv panel auxilary relay with retrofitting arrangement 47 erectionwork 48 installation of 33 kv o / d vcb 1250 a 49 acsr dog conductor 50 installation of new 33 kv control panel for double t / f 51 installation of 33 kv line isolator 33 kv ( 800 amp. ) 52 replacementof defective 33 kv current transformer 400 / 200 / 1 53 replacementof defective 33 kv panelo / c + e / f idmt relay with retrofitting arrangement 54 replacement of defective 33 kv panel master relay with retrofitting arrangement 55 replacement of defective 33 kv panel auxilary relay with retrofitting arrangement 56 replacement & supply ofdefectiveclosing coil 57 replacement & supply ofdefectivetripping coil 58 replacement & supply of defective main contact block of breaker 59 replacement & supply of defective tnc switch 60 replacementof defective control cableform panel to vcb 2*2.5 sq mmarmoured cable 61 replacement of defective control cableform panel to vcb 4*2.5sq mm armoured cable 62 replacement and supply of vcb charging motor of appropriate rating 63 replacement and supply of defective / burnt mcb of appropriate rating 64 replacement and supply of defective / burnt auxillary switch of appropriate rating 65 replacement and supply of defective antipumping relay 66 replacement& supply of defectiveled indicator 67 replacment & supply of defective ampere meter 68 replacment & supply of defective volt meter 69 replacment & supply of defective tnc switch 70 replacment & supply of defective local / remote switch 71 replacment & supply of defective buzzer 72 replacement & supply of defective wti 73 replacement & supply of defective oti 74 replacement & supply of defective magnetic oil gauge of power tf 75 replacement & supply of defective bucholtz relay 76 replacement & supply of defective main contact block of transformer 77 replacement and supply of defective breather with silica gel 78 servicing of electrical system for proper opening, closing & tripping of 33 kv breakers including providing necessary internal wiring, lugs, ferrules of appropriate rating and colour coding& servicing mechanical system for proper opening, closing & tripping of 33 kv breakers & servicing 33 kv panel for proper operation of opening, closing, tripping, alarm, indication of breaker including proper internal wiring of panels and proper wiring between panels, dc charger, 33 kv breaker, 33 kv cts, 33 kv pts, power transformer oil temprature indicator, winding tempratureindicator, oil level indicator, bucholtz relay etc with proper contol cable, lugs, ferrules of appropriate rating and colour. 79 replacement of jarjar conductor including heavy duty pg clamp, heavy duty conector, isolater jaw etc complete 80 rectification of power t / f leakage
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 1ff285cb-1917-41ca-a895-c5d9a2bc48ee
Download aoc
Download boqcomparativechart
Download finance_1422576
Download finsummary_1422576
Download technical_1422576
Download techsummary_1422576
Download File Name File Description
Download 17962c7a-2c72-4116-96d6-8f4434af3ac1 Tender Documents
Download BOQ_1422576 Tender Documents
Download form Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000