1.
Civil Aviation #11297332 AOC
Bids Are invited for Annual Maintenance Contract of Fire Hydrant including all pumps, panels, cables, piping , Hydrants etc. , intelligent type analogue addressable Fire Alarm system and Sprinkler system including all pumps, panels, cables, piping, sprinklers etc. at Aurangabad Airport for all preventive maintenance and checks as per manufacturers manual including attending to complaints/ Faults/ break down and taking rectification action, ensuring serviceability/ satisfactory working conditions of the system, maintenance of all records, documentation etc. as per the detailed specifications, terms & conditions covered under this contract on all days including sundays and holidays as per requirements of AAI. , Annual maintenance contract of Kirloskar make DG pump set (with specification mentioned under (A)) i/c engine control panel and other accessories of DG pump set.Job includes monthly visits for carrying out preventive maintenance, attending any number of breakdown calls when required, carrying out B and C check, minor repairs etc. as per manufacturers recommendations / standard practice and as per the scope of work, complete as required. A) Engine type - 6R1080, Rating - 79 hp, RPM - 1500, governing class - M2. , Supplying, installation, testing & commissioning of Conventional Photo Electric Smoke detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required.(Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS). , Supplying, installation, testing & commissioning of addressable Photo Electric Smoke detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required. (Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS). , Supplying, installation, testing & commissioning of Conventional Multi Sensor detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required.(Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS). , Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable multi criteria detector {Smoke + heat } with inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications ,complete as required. (Cost of plug in common base shall deemed to be included in cost of detectors) , Supplying, installation, testing & commissioning of conventional manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc.complying to relevant IS etc. as required.(Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX). , Supplying, installation, testing & commissioning of conventional response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. complying to relevant IS etc. as required. (Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX). , Supplying, installation, testing & commissioning fire alarmsounder with facility to make announcement, mounted in M.S.box (16 SWG) with hinged cover plate & suitable for operationwith amplifier i/c line matching transformer etc. complete asrequired.(Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX). , Supplying, installation, testing & commissioning of conventional fire alarm panel , 16 X 2 dotmatrix LCD display, suitable for eight zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all otherstandard facilities as per IS:2189, complying relevant national fire alarm code for local fire alarm system with mimic diagram for allarea/zone covered, complete with all connections. The panel shall have input of 240 volts AC power supply, automatic battery charger, 24 volts, 2 X 12 volts, 12 Ah sealed lead acid maintenance free batteries sufficient for 24 hours normal power backup & working, interconnections. The panel shall be UL listed & FM approved and shall be hookup with PA system and along with auto dialer facility etc. as required. (Approved Makes : APOLLO/ AUTRONOCA (UTC)/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLEY IAS/ GROUP4/ MATHER & PLATT/ MINIMAX). , Supply, Installation, Testing & Commissioning of UL / EN listed (latest version) Modular Microprocessor based expandable intellegent Addressable Type Fire Alarm Control Panel of following loops, with minimum 320 character graphics / LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM) ,The panel should be equiped with loop capacity to take minimum 240 intellegent addressable detectors/ devices (In any combination ) in one loop. Four access levels, capable of taking Protocol Devices, Graphical Display, sufficient numbers of programmable relay controls for controlling ventilation fan, fire pump room, monitoring of fire sprinkler and fire hydrant pump, 230 volts, 50 Hz AC power supply, automatic battery charger, 24 volts sealed maintenance free lead acid batteries sufficient for 2 hours normal working and then be capable of operating the system for 30 minutes during an emergency / fault conditions along with battery stand as required. The panel shall have facility for seamless integration with PA system (For Giving triger Signal to Start pre-recorded Digital Voice Evacuation from PA system in case of fire ). The panel shall be compatible for Building Management System with open protocol BACNET / MODBUS etc. as per specification, complete as required.(Approved Makes : APOLLO/ AUTRONOCA (UTC)/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLEY IAS/ GROUP4/ MATHER & PLATT/ MINIMAX). , Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring &LSZH outer sheath complete as required.(Approved Makes : CMI/ KEI/ BONTON/ POLYCAB/BATRA HENLAY/ RR CABLE/ WAREXHAM). , Supply of 63mm dia., 15mtr. long RRL hose pipe (ISI Marked) with necessary male and female gun metal / SS couplings duly binded with GI wire, rivets etc. conforming to IS- 636 (Type-A) complete as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX). , Supply of standard short sized branch pipe constructed from SS material of 63mm dia.and be complete with male instantaneous spring lock type coupling for connection to the end of hose pipe,Externally threaded to receive nozzle,conforming to IS:903 etc. complete as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX). , supply of nozzle,20mm inner diamter,made of SS,screw threads at the inlet connection to match with the threading of 63mm dia branch pipe with inlet end of hexagonal head to facilitate screwing conforming to IS 903 etc. as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX).
Contract Date: Ref. Documents Contract Value : 13.35 Lakh
Boards / Undertakings / PSU No of Bidders 11
Daman and Diu View Result →
2.
Educational and Research Institute #11294683 Technical Bid
Tender for Purchase Of Digital And Analog Communication Lab Equipment(Tansche) , Digital And Analog Communication Lab Equipment(Tansche) , Digital Ic Trainer Kit: 1. Equipped With 16 High-Visibility Leds For Monitoring Experimental Outputs And Logic Status Indication. 2. Dedicated Driver Circuitry Provided For Reliable Operation And Protection Of All 16 Leds During Experimentation. 3. All 16 Driver Input Lines Are Terminated Through Banana Connectors For Flexible And Easy External Interfacing. 4. Includes 16 Spdt Toggle Switches For Generating Manual Logic Input Conditions In Digital Electronics Experiments. 5. Additional 16 Leds Provided To Display The Real-Time Status Of Individual Switch Operations. 6. One Terminal Of Each Spdt Switch Is Externally Accessible Through Banana Sockets For Convenient Circuit Connections. 7. Built-In Variable Clock Generator Enables Pulse Generation For Sequential And Timing-Based 8. Digital Experiments. 9. Frequency Adjustment Provided Through Potentiometer And Rotary Switch Combination For Precise Clock Selection. 10. Clock Output Is Terminated Through Banana Connectors For Quick Integration With External Circuits And Trainer Modules. 11. Features Dual 7-Segment Led Display With 7447 Decoder/Driver Ic For Bcd To Display 12. Conversion Experiments. 13. Inputs Of The 7447 Drivers Are Terminated At Banana Connectors For Direct Digital Logic Interfacing. 14. Includes Solderless Breadboard For Rapid Circuit Prototyping And Reusable Experimental Setup Development. , Amplitude Modulation Trainer Kit: 1) On Board Carrier And Modulating Signal Generator With Amplitude And Frequency Adjustable 2) Carrier And Modulating Signals Are Provided In The Unit With Frequency Variable. 3) In-Built Regulated Power Supply 4) On Board Envelope Detector 5) Schematic Diagram Provided In The Front Panel Modulating Signal Frequency : (300Hz-3 Khz) Amplitude : (0-5) V Carrier Signal Carrier Signal Frequency : 10 Khz - 50 Khz Amplitude : (0-15) V Type Of Modulator : 1. Ring Modulator 2. Transistor Based Modulator Method Of Modulation : 1. Under Modulation 2. Critical Modulation 3. Over Modulation , Fm Trainer Kit 1) On Board Sine Wave Generator 2) Provision To Study Modulation & Demodulation In The Same Unit 3) Test Points To Study Different Waveforms 4) In-Built Audio Power Amplifier 5) Mic Pre Amplifier 6) Built-In Power Supply 7) Sine Wave Generator : Frequency - 100Hz To 1.2 Khz With Amplitude Adjustable, (0-5V) 8) Fm Modulator : Direct Fm 9) Carrier Frequency : 20 Khz (Low), 367 Khz(High) 10) Fm Demodulator : Pll Detector, Quadrature Detector, Foster Seelay Discriminator / Phase Discriminator, Ratio Detector Are Provided. 11) Audio Power Amplifier : Gain 100 12) Mic Pre Amplifier : Gain 20 , Ask, Fsk, Psk Trainer Kit A S K Modulation & Demodulation Trainer  On Board Data Generator Circuit.  Auto / Manual Mode (Data Generation)  External Patching Provision Provided Between The Modulator And Demodulator.  Built-In Power Supply.  Modulator And Demodulator Are Separately Provided.  Easy Interconnections Are Made By Patch Cords.  Mode : Auto / Manual  Input Data Rate : 800Hz To 2 Khz  Any External Ttl Compatible Sequence With Frequency Up To 2.1 Khz.  Carrier Frequency : 20 Khz  Power Supply Ratings: 230V + 10%, 50Hz. F S K Modulation & Demodulation Trainer  Three Types Of I/P Sources - Manual Input , Square Input , Rs232 Input  Fsk Modulator With, Mark Frequency: 1070 Hz Space Frequency: 1270  Pll Based Fsk Demodulator  Output Provided Through Bs2 Connector And Serial Port.  Built-In Power Supply. P S K Modulation & Demodulation Trainer  On Board Programmable Data Generator  On Board Carrier Generator  Mimic Diagram In The Front Panel  Type Of Modulator : Balance Modulator  Type Of Demodulator : Balance Demodulator  Binary Inputs - 8-Bit Data Length  50 Khz, Clock  Carrier Inputs Frequency : 200 Khz Amplitude : 2 V Pp  Level Converter : Unipolar To Bipolar  Supply Ratings Ac Input (230V, ± 10%, 50Hz) Dc Output (+12V,-12V, +5V, Gnd , Pam, Pwm, Ppm Trainer Kit  Pam- Ppm- Pwm Modulation And Demodulation Techniques, Using Natural And Flat-Top Sampling.  Natural Sample, Sample And Hold And Flat-Top Outputs.  Selectable 2 Different Sampling Pulse Frequencies On Board.  On Board Sine Wave Generators.  Voice Communication Using Dynamic Microphone And Speaker  On Board Filters And Amplifier  Functional Blocks Indicated On Board Mimics  Input- Output And Test Points Provided On Board.  Built In Dc Power Supply  Fully Documented Operating Manual  Switch Faults  Pulse Modulation Techniques : (1) Pulse Amplitude Modulation (2) Pulse Width Modulation (3) Pulse Position Modulation  Crystal Frequency : 6.14Mhz  Sampling Frequency : 16 Khz, 32 Khz  Sine Wave Generator : 1 Khz & 500 Hz, Amplitude (0-5) V, Tolerance +5%  Low Pass Filter : 4Th Order Bw Filter, Cut Off Frequency 3.4 Khz  Voice Communication: Voice Link Using Dynamic Mic & Speaker  Ac Amplifier : With Adjustable Gain Control  Interconnections : Uninsulated Sockets.  Power : 230V, 50Hz  Accessories : Manual Set Of Patch Chords, Microphone & Speaker
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 14
3.
Educational and Research Institute #11294681 Technical Bid
Tender for Purchase Of Trainer Kits And Function Generator , Trainer Kits And Function Generator , Function Generator Frequency Range : 0.11 Hz To 3.33 Mhz Waveforms: Sine, Triangle, Pulse, Square Ttl And Cmos Outputs Duty Cycle Control And Variable Dc Offset Control -20Db * 2 And Variable Attenuator. Waveform Types Sine, Triangle, Pulse, Square Ttl And Cmos Outputs Ttl Output Range 4Vpp - 20Vpp 4.8Vpp Sine Wave Distortion 0.11 Hz-100: Max 0.5 % 0.1 Mhz - 0.3 Mhz Max 1.5% 0.3 Mhz - 3Mhz Max 3% Square Wave Rise /Fall Time Overshoot Duty Cycle ≤ 60Ns ≤ 7.5% 50% Pulse Wave Pulsewidth Range Rise /Fall Time 15 % To 85 % ≤ 60Ns Ttl Output Level Amplitude Fan-Out Rise /Fall Time ≥4.8Vpp 10Ttl Load ≤ 60Ns The Display Shows Function And Frequency On The 16*2 Lcd Display Amplitude We Get From 1.5 V Pp To 20 V Pp And Varies As Per The Different Frequency Range Amplitude Distortion Without Load Wave 1 Mhz 2Mhz Sin 20 Vpp 18 Vpp Square 20 Vpp 20 Vpp Triangle 20 Vpp 16 Vpp Pulses 20 Vpp 18 Vpp Ttl 5 Vpp 5 Vpp Dc Varies From 0 ± 5V Dc Function Generator Frequency Range : 0.11 Hz To 3.33 Mhz Waveforms: Sine, Triangle, Pulse, Square Ttl And Cmos Outputs Duty Cycle Control And Variable Dc Offset Control -20Db * 2 And Variable Attenuator. Waveform Types Sine, Triangle, Pulse, Square Ttl And Cmos Outputs Ttl Output Range 4Vpp - 20Vpp 4.8Vpp Sine Wave Distortion 0.11 Hz-100: Max 0.5 % 0.1 Mhz - 0.3 Mhz Max 1.5% 0.3 Mhz - 3Mhz Max 3% Square Wave Rise /Fall Time Overshoot Duty Cycle ≤ 60Ns ≤ 7.5% 50% Pulse Wave Pulsewidth Range Rise /Fall Time 15 % To 85 % ≤ 60Ns Ttl Output Level Amplitude Fan-Out Rise /Fall Time ≥4.8Vpp 10Ttl Load ≤ 60Ns The Display Shows Function And Frequency On The 16*2 Lcd Display Amplitude We Get From 1.5 V Pp To 20 V Pp And Varies As Per The Different Frequency Range Amplitude Distortion Without Load Wave 1 Mhz 2Mhz Sin 20 Vpp 18 Vpp Square 20 Vpp 20 Vpp Triangle 20 Vpp 16 Vpp Pulses 20 Vpp 18 Vpp Ttl 5 Vpp 5 Vpp Dc Varies From 0 ± 5V Dc 1. Equipped With 16 High-Visibility Leds For Monitoring Experimental Outputs And Logic Status Indication. 2. Dedicated Driver Circuitry Provided For Reliable Operation And Protection Of All 16 Leds During Experimentation. 3. All 16 Driver Input Lines Are Terminated Through Banana Connectors For Flexible And Easy External Interfacing. 4. Includes 16 Spdt Toggle Switches For Generating Manual Logic Input Conditions In Digital Electronics Experiments. 5. Additional 16 Leds Provided To Display The Real-Time Status Of Individual Switch Operations. 6. One Terminal Of Each Spdt Switch Is Externally Accessible Through Banana Sockets For Convenient Circuit Connections. 7. Built-In Variable Clock Generator Enables Pulse Generation For Sequential And Timing-Based 8. Digital Experiments. 9. Frequency Adjustment Provided Through Potentiometer And Rotary Switch Combination For Precise Clock Selection. 10. Clock Output Is Terminated Through Banana Connectors For Quick Integration With External Circuits And Trainer Modules. 11. Features Dual 7-Segment Led Display With 7447 Decoder/Driver Ic For Bcd To Display 12. Conversion Experiments. 13. Inputs Of The 7447 Drivers Are Terminated At Banana Connectors For Direct Digital Logic Interfacing. 14. Includes Solderless Breadboard For Rapid Circuit Prototyping And Reusable Experimental Setup Development. , Strain Gauge Study Trainer This Trainer Shall Consists Of Cantilever Jig And Strain Gauge Bonded On The Cantilever, A Signal Conditioner For The Strain Gauge, Instrumentation Power Supply, 3½ Digit Digital Indicator Display The Strain. * Cantilever Beam Of Maximum Weight Upto 1Kg. * A Pan With Slotted Weights To Vary The Strain. * Built In Instrumentation Power Supply * Signal Conditioning Card For The Strain Gauge * 3½ Digit Digital Display For Displaying The Strain * Offset And Gain Variable Provision * Logical Diagram With Panel. * Mounted In Sleek Cabinet. 1) On Board Carrier And Modulating Signal Generator With Amplitude And Frequency Adjustable 2) Carrier And Modulating Signals Are Provided In The Unit With Frequency Variable. 3) In-Built Regulated Power Supply 4) On Board Envelope Detector 5) Schematic Diagram Provided In The Front Panel Modulating Signal Frequency : (300Hz-3 Khz) Amplitude : (0-5) V Carrier Signal Carrier Signal Frequency : 10 Khz - 50 Khz Amplitude : (0-15) V Type Of Modulator : 1. Ring Modulator 2. Transistor Based Modulator Method Of Modulation : 1. Under Modulation 2. Critical Modulation 3. Over Modulation , Load Cell Study Trainer This Module Shall Consists Of A 5Kg Load Cell Sensor, Weights, Signal Conditioner And 3½ Digit Digital Indicators To Display The Load. * Strain Gauge Based Load Cell Sensor Of 5Kg Capacity * A Pan Provision For Placing The Standard Weights Signal Conditioner For Load Cell (Output 0-5V) * Built In Instrumentation Power Supply * Zero Calibration Provision. * 3½ Digit Digital Indicator To Display The Applied Load. * Mounted In A Elegant Powder Coated Cabinet With Mimic Diagram 1) On Board Sine Wave Generator 2) Provision To Study Modulation & Demodulation In The Same Unit 3) Test Points To Study Different Waveforms 4) In-Built Audio Power Amplifier 5) Mic Pre Amplifier 6) Built-In Power Supply 7) Sine Wave Generator : Frequency - 100Hz To 1.2 Khz With Amplitude Adjustable, (0-5V) 8) Fm Modulator : Direct Fm 9) Carrier Frequency : 20 Khz (Low), 367 Khz(High) 10) Fm Demodulator : Pll Detector, Quadrature Detector, Foster Seelay Discriminator / Phase Discriminator, Ratio Detector Are Provided. 11) Audio Power Amplifier : Gain 100 12) Mic Pre Amplifier : Gain 20 , Lvdt Study Trainer It Shall Consists Of A Lvdt Sensor, Signal Conditioner And A Digital Indicator To Display The Displacement Cantilever Jig With Micrometer. * Lvdt Sensor With Micrometer (Range: 0-25Mm) * Signal Conditioner For Lvdt * Displacement Calibrated Range From (-10Mm To + 10Mm) * Output Voltage (-5V To +5V) * Built In Instrumentation Power Supply * A 3½ Digit Digital Indicator To Display The Displacement * Mounted In A Elegant Powder Coated Cabinet. * Logical Diagram In The Panel Detailed Documentation , Thermistor Study Trainer  One Negative Temperature Co- Efficient Type Thermistor Sensor Is Used As A Temperature Sensor.  Signal Conditioner For Thermistor Transducer: Output 5-0V  Built In Instrumentation Power Supply  A 3½ Digit Digital Indicator Is Used For Voltage Display  Zero Calibration Provision  Water Bath Is Used As A Heat Source.  Thermometer Is Provided To Monitor The Actual Temperature.  Mounted In An Elegant Cabinet , Thermo Couple Study Trainer * One J Type Thermocouple Is Used As A Temperature Sensor * One Ad590 Sensor Is Used For Cold Junction Compensation * Signal Conditioner For J Type Thermocouple Output: (0-5V) * Built In Instrumentation Power Supply * 3½ Digit Digital Indicator To Display The Temperature. * Water Bath Is Used As A Heat Source * Zero Calibration Provision * Thermometer Provided To Monitor The Temperature * Mounted In A Elegant Powder Coated Cabinet * Logical Diagram In The Panel Detailed Documentation , Rtd Study Trainer * Pt100 Type Rtd Is Used As A Temperature Sensor * 3 Wire Configurations Is Provided Signal Conditioner For Rtd Output Is (0-5V) * Built-In Instrumentation Power Supply * A 3½ Digit Digital Indicator To Display The Temperature * Water Bath Is Used As A Heat Source. * Thermometer Provided To Monitor The Actual Temperature * Mounted In A Closed Cabinet. Detailed Documentation. , Piezo Electric Transducer Study Trainer This Trainer System Shall Consists Of Vibration / Acceleration Sensor Of Piezo Electric Type, Signal Conditioner, Regulated Power Supply, 3½ Digit Digital Indicator Etc Provided To Study The Characteristics Of Piezo Electric Sensor * Vibration Sensor Of Piezo Electric Type Mounted In The Base Plate To Sense The Vibration Of The Material. * Precision Rectifier Circuit For Above Sensor. * Signal Conditioner Of (0-10)Vdc * Ic Regulated Power Supply * 3½ Digit Digital Indicator To Display The Voltage. * Logical Diagram In The Panel * Mounted In A Powder Coated Closed Cabinet. Vibrator Exciter  One Mechanical Setup Provided  One Vibration Motor To Vibrate The Mechanical Setup # I/P : 230V Ac/50 Hz # Power : Max: 0.5 Hp One Auto Transformer Is To Vary The Input Voltage For Mechanical Setup , Schrings Bridge * 4 Arms With Suitable Connectors. * Provision To Connect The Unknown Capacitance At One Arm * Two Potentiometers Provided At Two Arms To Obtain The Bridge Balance Condition. * Input Of The Bridge Is Taken From A 1Khz Fixed Amplitude Oscillator. * One Audio Amplifier With Miniature Speaker Is Provided To Detect The Bridge Balance Condition Acoustically. * Measuring Range : 0.001Uf - 2.0Uf * Sensitivity : +0.1Uf * Tolerance : +5% * All Are Housed In A Metal Cabinet * Detailed Documentation * Required Patch Chords Are Provided Decade Capacitance Box Dial 1 :0-0.01Mfd In Steps Of 0.001Mfd Dial 2 :0-0.1Mfd In Steps Of 0.01Mfd Dial 3 :0-1Mfd In Steps Of 0.1Mfd Dial 4 :10Mfd In Steps Of 1Mfd Total Range : 0-11.11Mfd , Maxwells Inductance Bridge * Four Arms Are Provided With Suitable Connectors * One Arm With Provisions To Detect The Nearest Range Of Unknown Inductance. * Two Arms With Variable Potentiometers Given To Balance The Bridge In Null Condition * One 1 Khz Oscillator Of Fixed Amplitude To Feed The Input To The Bridge. * One Audio Amplifier With Speaker To Detect The Bridge Balancing Conditions. * Measurement Range: 15Mh - 200Mh * Tolerance : +5% * Built-In Power Supply * Connector Facility Given To View The Output Of The Bridge Externally By Cro * All Are Housed In A Powder-Coated Cabinet With Logical Diagram. * Required Patch Chords Are Provided Decade Inductance Box Dial 1 :0-9Mh In Steps Of 1Mh Dial 2 :0-90Mh In Steps Of 10Mh Dial 3 :0-900Mh In Steps Of 100Mh Total Range :0-999Mh , Voltmeter Desk Top Analog Voltmeter (0-1V Dc, 0-10V Dc, 0-30V Dc, 0-5V Dc) Each 5 Nos , Ammeter Desk Top Analog Ammeter (0-10Ma Dc, 0- 50Ma Dc, 0-100Ma Dc, 0-500Microa Dc) Each 5 Nos , Digital Trainer Kit * 16 LedS Are Provided To Indicate The Status/Outputs Of An Experiment. * Drivers Provided To Drive The 16 LedS * All The 16 Inputs Of The Driver Are Terminated At Banana Termination For Easy Wiring Of Any Experimental Setup. Input Switches : * 16 Spdt Switches As Logical Inputs Are Provided. * 16 LedS Provided To Display The Status Of The Switches. One End Of Each Spdt Switch Is Terminated At A Banana Termination For Easy Wiring. , Ic Tester It Is The Latest Microcontroller Based Universal Ic Tester. It Functionally Tests A Wide Variety Of Analog/Linear Ics Including Adc,Dac,Dpm Ics, Op Amps, Transistor Arrays, Waveform Generators And Digital Ics Including Microprocessors, Microcontrollers, Eproms, Rams, Peripheral Devices Apart From 74 Series Of Ttl Ics And 40/45 Series Of Cmos Ics
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
4.
Educational and Research Institute #11161433 Price Bid
Procurement Of Equipment, Instruments, Machinery, Tools Etc. Related To Laboratories And Workshops Of Electronics And Telecommunication Engg., Engineering Physics, Engineering Mechanics Of Mirik Government Polytechnic, Mirik, Dist. Darjeeling, 734214 , Spherometer (Screw Pitch 0.05 Mm And Lc 0.005 Mm) , Concave Mirror (Focal Length 20 Cm) , Convex Mirror (Focal Length 20 Cm) , Concave Surface (Focal Length 20 Cm Diameter 50 Mm) , Hooks Law Apparatus (Consisting Of 30 Cm Long Mirror Scale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand) , Mercury (Distilled Liquid Mercury, Grade Std.-Biotech Grade) , Flywheel Apparatus (Thickness: 4.4 Cm Diameter :20 Cm) , Cantilever (Length 100 Cm, Hook At One End, C Clamp) , Light Weight Hanger (Metal Slotted Weight Mechanics Physics Experiment Equipment Set With Hook With Weight Of Each Mass Of The Order Of 50Gm Or 100 Gm) , Inverse Square Law Apparatus (Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter) , Stopwatch (Digital Stopwatch With Ms Count) , High Resistance Box (Resistance Box Plug With 1 To 10 K Ohm Resistance) , Winch Crab Single Purchase With Weight [Experiment Set Up Winch Crab Single Purchase- Fitted With Heavy Cast Iron Wall Brackets The Grooved Wheel Is Of 25 Cm Diameter And Gears Are Machine Cut.String, Weight Box With Pan. ] , Winch Crab Double Purchase Without Weight [Experiment Set Up Winch Crab Single Purchase- Fitted With Heavy Cast Iron Wall Brackets The Grooved Wheel Is Of 25 Cm Diameter And Gears Are Machine Cut. ] , Worm And Worm Wheel Single Without Weight [Experiment Set Up Consisting Of Machine Cut Worm Gear Of 25 Cm Diameter, Carrying A Metal Drum On 12 Cm Diameter, And Machine Cut Worm On Steel Spindle Carrying A 12 Cm, Complete With Effort Pulley, String With Pan.] , Worm And Worm Wheel Double Without Weight [Experiment Set Up Consisting Of Machine Cut Worm Gear Of 25 Cm Diameter, Carrying A Metal Drum On 12 Cm Diameter, And Machine Cut Worm On Steel Spindle Carrying A 12 Cm, Complete With Effort Pulley, String With Pan.] , Wheel & Axle Simple Without Weight [Standard Setup For Lab.] , Simple Screw Jack With Weight [Experiment Set Up Screw Jack ( Weights)All Metallic Construction Accurately Machine Cut Screw With A Pitch Of 5 Mm Carrying A Double Fanged Turn Table Of About 20 Cm Diameter. Fitted On A Heavy Cast Iron Base And Complete With Two Adjustable Pulleys, Cord And Hook. Weights Are Included.] , Combined Inclined Plane & Friction Slide Apparatus Iron Base & With Weight [Standard Setup For Lab.] , Parallel Forces Apparatus [Experiment Set Up Simple Supported Best Type Supported At Its End. For Verification Of Condition Of Equilibrium Of Parallel Forces, Law Of Lever & Forces On Beam Etc. Consisting Of Two Compression Thrust Type 10 Kg Tubular Spring Balances Fixed On Wooden Polished Board, A Wooden Beam With Steel Back Plate. Complete With Two Strups, Hooks & Two 10Kg Weights. ] , To Verify Lami’S Theorem [Gravesand Apparatusboard: Wooden With Metal Base Pulley: Z-Pullies (2 Nos) With Adjustable Distance Weight Set: 5X50 G (3 Sets). ] , Simple Jib Crane Apparatus Iron Stand With Weight [Experiment Set Upwith Consisting Of A Tubular Compression Balance, Pivoted About An Axis Fitted To The Base. The Tie Chain Has An Adjustable Angle Bracket And Fitted With A 10Kg Extension Balance. Completion Wooden Base With 1.2 Meter Jib. With Weights. ] , Mini Drafter, T Square, Protractor, Set Squares, Compass, Divider [Made Out Of Wood. To Be Used In Chalk Board] , Model Of Geometric Constriction (Solid Cube, Solid Primed, Cylinder, Cone, Hexagon, Tetrahedron ) [Made Out Of Wood. To Be Used In Chalk Board] , Amplitude Modulation And Demodulation Trainer Kit [Message Signal:100 Hz To 2.8 Khz, Carrier Signal 28 Khz To 108 Khz,Modulation : Balanced Modulator, Amplifier : Op Amp Based, Demodulation : Diode Detector & Lpf(6Th Order)] , Frequency Modulation Anddemodulation Kit [On-Board Message Signal With Variable Amp/Freq,On Board Carrier Signal Fm Modulation Using Xr 2206Ic,Demodulation Using Pll Detector And Lpf 4Th Order Lpf,Internal Power Supply +5V , +12V/ 500 Ma] , Super Heterodyne Am Radio Receiver Trainer Kit To Measure Sensitivity, Selectivity And Fidelity [On Board Variable Capacitor Tuning,Receiving Antenna,Local Oscillator,Bfo, Rf Amplifier, Mixer,If Amplifiers, Detectors, Agc,Audio O/P Amplifier, Speaker.Frequency Range: 400Khz To 1700Khz,If Frequency: 455 Khz.] , Pam, Pwm And Ppm Modulation And Demodulation Trainer Kit [Provides Sine Waveform Output Of 250Hz, 500Hz, 1 Khz, And 2 Khz With Amplitude Adjustments Of 0 - 5Vp-P. Switch Selectable Sampling Clock Of 4, 8, 16, 32 Khz. On-Board Features Analog Sample Circuit/Output, Sample & Hold Circuit/Output, Flat Top Circuit/Output, 4Th Order Butterworth Low Pass Filter With Cut Off Frequency Of 3.4 Khz.] , Analog Signal Sampling & Reconstruction Trainer Kit [±15V D.C. At 100Ma, Ic Regulated Power Supply, A.F. Signal Generator For Modulating Signal.Sampling Clock Generator To Provide Sampling Clock And Gate Pulse. Modulator Circuit For Flat-Top Natural And S/H Circuit. Demodulator Circuit To Reconstruct Input (Sinewave)] , Telephone Receiver Trainer Kit [Line In Section : One Dot Line Connection Port.Handset : One Handset Connection Port. Keyboard : 4X3 Matrix Keyboard.Dialer : Tone And Pulse. Facilities : Redial Up To 32 Digits, Mute, Redial, Flash, Pause Switches.Indicators : Line In, Hook, Tone And Ringer, Call Mute Section.Control : Ringer Volume Control, Ringer Speed Control.Speech Path : Fully Non-Blocking.Dial Pulse Ratio : 10 Pps + / - 10%.] , 100Mhz Digital Oscilloscope [Bandwidth: 100 Mhz, 2 Analog Channels+ Ext With Probes Included Rise Time: =3.5 Ns, Real-Time Sample Rate Of 1 Gsa/S 1% Dc Gain Accuracy Should Support Rs232/Uart, I2c And Spi Bus Triggers And Decodes Usb And Ethernet Connectivity] , 30Mhz Analog Cro [Dual Trace Dual Channel Oscilloscope. Bandwidth: 20Mhz. Full Bandwidth Sweeping Circuit , Tv-H / Tv-V Synchronization And Trigger-Lock To Observe All Kinds Of Signals Stably. Y Deflection Operation: Y1, Y2, Alt, Chop, Add, Mode.Horizontal Sweep Mode: Auto, Trig, Lock, Single.X-Y Mode Input: X-Axis Yi And Y-Axis Y2.] , 2 Mhz Function Generator [Frequency: 1Hz – 2 Mhz Sine, Square, Triangle, Ttl Output] , Digital Storage Oscilloscope (100 Mhz) [Bandwidth 100 Mhz, Channels: 2+, Display: Tft Color Lcd Of Suitable Size (Capacitive Touchscreen). Sampling Rate: 1 Gsa/S Real Time, Sampling Mode: Normal, Average (2, 4, 8, 16, 32, 64, 128, 256), Peak Detect. Mathematics: A+B, A-B, A×B, Fft (Fast Fourier Transform). Fft Windows: Rectangle, Hanning, Hamming, Blackman. Auto Measurement: Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay1-2 (Rise), Delay1-2(Fall) ] , Trainer Kit For Rectifier With And Without Capacitor Filter For : — (A) Half-Wave Rectifier, (B) Full-Wave Rectifier, (C) Bridge Rectifier [Transformer Rating : 9-0-9V/200Ma, Rectifiers : Half Wave; Full Wave - Bridge, Center Tapped Rectifier,On-Board Dc Voltmeter : 0 - 20V,On-Board Ac Voltmeter : 0 - 20V,Load : Variable Resistive Load 10K,Filter Circuit : In-Built- Capacitor (3Nos.),In-Built- Inductor (1No.),Input Line Voltage : 230V Ac ± 10%, 50Hz] , Push-Pull Amplifier Trainer Kit [I.C Regulated Power Supply : +6 V.Digital Ac Voltmeter: 0 – 20 V.Digital Ac Milliammeter : 0 – 200 Ma.Set Of Resistances.Set Of Capacitors.Two Transistors Cl 100 And Ck 100.Connecting Wire.] , Fet Characteristics Trainer Kit [Variable Dc Regulated Power Supply Of 0-5V At 250Ma. Dual Range Dc Voltmeter Of 1.5V/15V.Dc Ammeter Of 0-20Ma.] , To Determine Frequency Response Characteristics Of Rc Coupled Amplifier Circuit And Calculation Of Bandwidth, Midband Gain, Input Impedance And Output Impedance For: (A) Single-Stage Amplifier (B) Double-Stage Amplifier [Sine Wave Oscillator 15Hz To 150Khz In Four Ranges With Amplifier & Amplitude Adjustable.Three Decade Resistances Bank In Steps Of 1K, 10K & 100K Per Steps Total Step 30.Two Pnp Transistors.] , Mosfet Characteristics Trainer Kit [On Board Ammeter And Voltmeter,Dual Variable Dc Power Supplies,On Board Mosfet And Fet With Resistors To Perform Experiments] , To Study The Input And Output Characteristics And To Find The H-Parameters Of A Bjt For : — (A) C-E Configuration, (B) C-C Configuration, (C) C-B Configuration [Power Supply 1) 0-1V Dc 2) 0-10V Dc.Meters Dc 65Mm Four Dial V, V , Ma Ua/ Ma.Transistor Cl100/ Similar] , Component Development System [Power Supplies On Boards 0-15 V And 0-30 V, 250 Ma Each Variable.Fixed Dc Regulated Power Supplies 15 V/250 Ma And 5 V/250 Ma.Ac Power Supply 15-0-15 V For Rectifier Applications.Various Components On The Trainer Set. ] , Kcl & Kvl Trainer Kit [Two Dc Ic Regulated Power Supplies 0-12 V/150 Ma, Two Mr65 Square/Digital Meters For Voltage & Current Measurement, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Power Cords 230 V, 50 Hz] , Thevenin’S And Norton’S Theorems Trainer Kit [Power Supply 2?3?0?V, Regulated & Short Circuit Proof Variable Dc Voltage Source – 01 No. Fixed Resistance Of Different Values. Dc Voltmeter.Dc Ammeter. Glass Fuse For Short Circuit Protection. On/Off Switch With Indication Light. Patch Cords Suitable To The Terminals With Board For Easy Interconnection.All Above Accessories Will Be Fitted On Bakelite Sheet Fixed On Box.] , Superposition Theorem Trainer Kit [Instrument Comprises Of Two Fixed Output Dc Regulated Power Suppliesof 12V & 5V At 500 Ma Current, Three Moving Coilmeter, Circuit Diagram Printed On The Front Panel & Connections Ofsupplies, Meter & Resistances Brought Out At 4Mm Sockets. ] , Maximum Power Transfer Theorem Trainer Kit [Ammeter 30Ma Dc. Voltmeter 12V Dc. Power Supplies: Dc Supply Ic Regulated 0-12V Dc, 150Ma. Operated On Mains Power 230V, 50Hz +10% Components Are Mounted On The Panels Are: Resistances 2Watts Variable Resistor Voltage Control Through Potentiometer. Fuse For Short Circuit Protection. Patch Cords 4Mm.] , Reciprocity Theorem Trainer Kit [Instrument Comprises Of One Fixed Output Dc Power Supply Of 12V At 300 Ma Current, Two Moving Coil Meters, Circuit Diagram Printed On The Fornt Panel & Connections Of Supplies, Meters & Resistances Brought On Terminals.] , Series And Parallel Resonant Circuit Trainer Kit [Analog Meters: Ammeter 20Ma Ac. Voltmeter 20V Ac. Components Mounted On The Panels Are: 3 Nos. Of Resistors Selected By Rotary Switch. 3 Nos. Of Capacitors Selected By Rotary Switch. 3 Nos. Of Inductors Selected By Rotary Switch.] , Low Pass And High Pass Filter( Rc & Lc) Constant K Type Trainer Kit [Instrument Comprises Low Pass Circuit Rc Type Instrument Comprises Low Pass Circuit Lc Type Instrument Comprises High Pass Circuit Rc Type Instrument Comprises High Pass Circuit Lc Type Instrument Fitted In Highly Shockproof Plastics Box] , T And ? Type Attenuator Trainer Kit [Instrument Comprises Ofdc Ic Regulated Power Supplies 0-15V/150Ma. Two Mr65 Square / Digital / Round Meters For Voltage & Current Measurement. T And Pie Network Provided On The Board. Variable Resistor Using Band Switch Is Mounted On The Board. Instrument Fitted In Highly Shockproof Plastics Box. Sufficient No Of 4Mm Patch Cords For Interconnection Instruction Manual For Student Workbook. Power Cords 230V, 50Hz] , To Study Standing Wave Pattern For A Transmission Line Of Finite Length With: (A) Open Termination, (B) Short Termination, And © Matched Termination. [Transmission Line : Coaxial Cable 100M ( 25M X 4 Nos) Impedance Matching Resistance : 0 To 100 ( 02 Nos ) Test Generator : 1. Sine Wave : 4 Khz To 4 Mhz. 2. Square Wave : 10 Khz. Interconnections : 4 Mm Sockets On All Input / Output Connections. Test Points : 10 On Board Circuit Mimic : Illustrates Functional Blocks For Ease Of Experimentation Power Requirement : 230V 10% 50Hz, 1 Ac. Accessories Provided : I. Set Of Patch Cords. Ii. Bnc To Bnc Cable. Iii. Bnc To Crocodile. Iv. Detailed Instruction Manual.] , Digital Trainer Kit (Experiment 1. -To Verify The Truth Table Of Not, Or, And, Nand, Nor, Xor, X-Nor With Ttl Logic Gates And Cmos Logic Gates. Experiment 2.- To Realize Different Boolean Expressions With Logic Gates. Experiment 3.-To Realize Half-Adder, Full-Adder, Subtractor, Parallel And Serial Full-Adder. Experiment 4-To Design 1’S Complement, 2’S Complement And 9’S Complement Adder-Subtractor.) [Dc +5V , 400Ma; Dc +12V, 250Ma; Dc -12 V, 250Ma, Dc0 To + 30V: Variable 100Ma,Ac Output: 12V-Ct-12V, 150Ma; Logic Data 8-Bit Debounced Set/Clear Ttl Output With Bicolour Led; Clock Generator I Hz To 200Khz Variable & Manual, Ttl & /Ttl(Complement) With Bicolour Led;Logic Probes 8-Bit 3-State Led Display High, Low, High Impedance; Function Generator Sine, Square, Triangle, 1 Hz To 250 Khz;Bread Boards : 3 X 820 Tie-Points; Total Short Circuit Protection From Any To Any Point On Board] , Complete Setup To Implement The Truth Table Of Encoder,Decoder, Multiplexer And De-Multiplexer. [The Trainer Kit Should Be Able To Verify The Truth Tables Of Truth Table Ofencoder,Decoder, Multiplexer And De-Multiplexer.] , Complete Setup To Design/Construct Parity Generator, Checker And Comparator. [Industry Standard Specification To Perform Relevant Experiments. ] , Flip Flop Trainer Kit [Kit For Verification Of Jk, Sr, D, And T Flip-Flop Truth Tables] , Complete Setup To Design / Construct Binary Synchronous And Asynchronous Counter. [Industry Standard Specification To Perform Relevant Experiments. ] , Complete Setup To Design / Construct Programmable Up/Down Counter. [Industry Standard Specification To Perform Relevant Experiments. ] , Complete Setup To Design Controlled Shift Register And Study Their Function. [Industry Standard Specification To Perform Relevant Experiments. ] , Trainer Kit To Study Different Memory Ics [Industry Standard Specification To Perform Relevant Experiments. ] , A/D & D/A Converter Trainer [Industry Standard Specification To Perform Relevant Experiments. ] , Trainer Kit To Interface Ttl And Cmos Ics. [Industry Standard Specification To Perform Relevant Experiments. ] , 8051 Trainer Kit [Operating Frequency : 10Mhz Crystal,40-Pin Ic Base | 40Pin-Zif Socket,2×16 Char Lcd Display,32 I/O Pins,32Kb-Sram,32Kb-Eeprom.] , Ct-31/51 Or 8031/51 Microcontroller Trainer Kit With Led Display, Usb Interface & Inbuilt Power Supply [Operating At 10/12 Mhz, On Board 8K Ram,8/16K Bytes Of Eeprom,48 I/O Lines,Hexadecimal Keyboard And Six Seven Segment Displays,Rs-232C Interface,Usb Interface] , Ct-31/51Lcdadu8031/51 Microcontroller Trainer With Lcd Display, Usb Interface, Adc, Dac& Inbuilt Power Supply [Trainer Based On 8051/89C52 Microcontroller.On Board 32K Ram.64 K Bytes Of Eeprom.20 X 2 Lcd Display.48 I/O Lines. Onboard Adc & Dac.] , Adc Interface Module [Usb Interface, Adc Module Module 10 Channel 12Bit Ad Sampling Data Acquisition Stm32 Uart Communication Adc Module] , Dac Interface Module [Operating Voltage 2.7-5.5 V. Interface Type I2c. Resolution 12 Bits.] , Lcd Display Module [Display Contents :16 * 2 Characters (5*8 Dots ). Lcd Size :80 X 36 Mm .Lcd Thickness :9.5 Mm.] , Keyboard Interface Module [5X4 Keys Matrix Keyboard. ] , Dc Motor Controller Module [Driver Module : L298n. Motor Supply Voltage (Max.): 46V.Motor Supply Current (Max.): 2A. ] , Stepper Motor Controller Interface Module [Robocraze Stepper Motor(28Ybj-48 Dc 5V 4 Phase 5 Wire) + Uln2003 Driver Board Compatible With Arduino] , Trafic Light Controller Module [Led Traffic Lights Signal Module/Digital Signal Output Traffic Light Module] , Temperature Measurement Module [Electrobot Dht11 Digital Temperature & Humidity Sensor Module For Arduino And Rpi] , Operational Amplifier Trainer Kit ( Ic 741 ) [Inbuilt Variable/Fixed Dc Regulated Power Supplies.Output Voltages : 0-5Vdc (2Nos.) (Variable), +12Vdc (Fixed).Transistor & Components Provided Ic : 741.Transistor : Cl 100 (Npn).] , Active Filter Trainer Kit (Lpf, Hpf, Bpf) [Opamp Based First Order Lpf, Hpf, Bof Trainer Kit (Mi-A14)] , Application Of Ic555 Timer Trainer Kit (Astable & Monostable Mv) [In-Built Regulated Dc Power Supply.On Board Manual Pulse Generator For Triggering The Monostable And Bistable Circuit.Inbuilt Led Output Indicator.Symbols And Diagram Are Printed On Glass Epoxy Pcb.] , Opamp Based Oscillator Trainer Kit ((A) Hartley, (B) Colpitt, (C) Phase Shift, (D) Wein Bridge) [Op-Amp Oscillator Trainer Mi-A13. Frequency 50-60 Mhz.] , Crystal Oscillator Trainer Kit (741 Based) [Industry Standard Specification To Perform Relevant Experiments. ] , Function Generation Kit (Using Icl8038) [Icl8038 Function Signal Generator Sine Triangle Wave Kit Diy Professional K5e8.Uses Icl8038 And High-Speed Op Amp, Higher Accuracy. Low Distortion Sine Wave: 1%.] , Voltage Regulator Trainer Kit (Using Ic723) [0-35V D.C. At 250Ma, Countinously Variable Unregulated Power Supply.D.C. Milliammeter, 65Mm Rectangular Dial With Switch Selectable Ranges Of 50Ma And 250Ma.D.C. Voltmeter, 65Mm Rectangular Dial With Switch Selectable Ranges Of 10V And 40V.Ic 723 Fitted On Base.Three Potentiometers.] , Function Generator Trainer Kit [Frequency Ranges: 1? Hz To 1?0? Hz, 1?0? Hz To 1?0?0? Hz Fuse:3?5?0? Ma, Slow Blow Automation Grade: Manual Power Supply:Max 2?3?0?V Ac, 5?0? Hz +/- 1?0?%] , Maxwells Bridge Trainer Kit [The Kit Contains A Bridge With Provision For Connections Of Capacitors And An Unknown Inductor. In Built Ac Supply [ 1 Khz And 2 Vpp ] And Dc Supply [ +5 V ] On Board. Two Nos Dial Resistances [ 50 Ohm To 200 Ohm ] And [ 1 Ohm To 11 Ohm ] In Step. A Dc And Ac Null Detector Using Selector Switch. A Dial Type Variable Capacitor [ Range 0.2 Uf Ro 1.2 Uf ] And Six Nos. Unknown Inductors [ Range 1 Mh To 12 Mh ].] , Lvdt Trainer Kit [Excitation Source Built In Ac Source 2.5 Khz Sine Approx. L.V.D.T. In Non Metallic Structure. Micrometer One (For Displacement) Displacement Range 10Mm. Test Points Sockets At Different Places For Signals. Potentiometer Two For Zero & Calibration Adjust Display (Mm) 3.5 Digit Digital Power Supply Ic Regulated Phase Detection Balanced Demodulator Power Supply Short Circuit &Overload Protected Mains 230V/50Hz Ac] , Strain Gauge Trainer Kit [Strain Gauge: 4 Mounted Upon Cantilever 150X3.5X3.5Mm, Stable Dc Voltage For Strain Gauge Bridge, Opamp Based,Precision Instrumentation Amplifier With Variable Gain,Potentiometer For Zero And Calibration Adjust,3.5 Digit Display For Strain/Weight, 230V 50Hz Ac] , Temperature Transducers Kit Using (A) Rtd (Pt-100) (B) Thermistor. [12 - 0 - -12 V 500Ma To Drive Digital Integrated Circuitry. 5 - 0 - -5 V 250Ma To Drive A To D Converter Signal Conditioning And Amplifying :Analog To Digital Converter. Display : 31/2 Digit Led Display Of 200 Mv Fsd Initial Set : Single Turn Potentiometer To Set Initial Temperature ( Room Temperature) Final Set : Single Turn Potentiometer To Calibrate The Instrument ( Max. Temperature) Select : 2 Way Rotary Switch To Select Rtdand Thermistor. Power On : Rocker Switch To Control Power Supply To The Instrument.] , Calibration Of A Single-Phase Energy Meter By Phantom Loading Trainer Kit [Usage/Application: Lab Experiment Connection:4?-Mm Patch Cord Single Phase Automation Grade:Manual Power:2?0?0? W Voltage:2?2?0?-2?4?0? V] , Calibration Of A Voltmeter Using Crompton Potentiometer Trainer Kit [This Trainer Is Supplied Along With Highly Regulated Dc Power Supplies To Operate The Unit. Further To Calibrate Pmmc Meters, Necessary Ratio Boxes Also Provided. Resistors Used In This Unit For Coarse And Fine Are Very Standard Type Made Of Manganin. This Enable The User To Measure The Potential In A Circuit Close To Micro Volts. Necessary Schematic/Wiring Diagram Printed On The Panel To Follow And Conduct Experiments. User Manual And 4Mm Patch Cords Supplied. Accessories Included: Necessary Dc Power Supplies, Ratio Boxes & Galvanometer Are Provided Alongwith The Unit.] , Cro Demonstration Kit [Crt : 6Rectangular Screen With Internal Graphical 8X10 Division (1Div-1Cm) Vertical Deflection Display : Ch1, Ch2, Add, Alt & Chop Deflection Factor : 5Mv/Div To 5V/Div +3%, 1Mv/Div To 1V/Div, +5% (X5), 10 Steps Rise Time : <17.2Ns Maximum Input Voltage : 250 (Dc + Ac Peak Value) When <1Khz (250V, Dc +Ac) Input Coupling : Ac, Dc & Gnd Polarity Selection : + (Ch2 Only) Display Mode : 1, 10 & X-Y Horizontal Deflection Time Base : 0.2Us/Div To 0.2S/Div, 9 Ranges Sweep Expansion : X10 Accuracy : +3% Triggering Mode : Auto, Norm, Tv-V, Tv-H Triggering Source : Int, Line & Ext. Trigger System Auto : 20Hz-20Mhz Norm : 0.5 Div Int, 0.5 Vp-P Ext Tv-H : At Least 1 Div Or 1 Vp-P Input Impedance : 1Mohm X-Y Phase Difference : <3 Degree, Dc-50 Khz Calibration Waveform : Frequency 1Khz 2%,Voltage 0.5 V 1%, Block Diagram Printed On The Top Panel, Power Requirement: 220 Vac +10% , 50 Hz] , Q-Meter Kit Formeasurement Ofq Of Coils. [Inductance Range:199.9Mµh-19.99H Resistance Range (Ohm):19.99O-19.99M? Capacitance Range:199.9P-1.999?F Capacitance Accuracy: ±(1%±2) Digital Lcr Bridge Meter Power:220 Volts/50Hz ±10%] , Spectrum Analyzer Trainer Kit [Industry Standard Specification To Perform Relevant Experiments. ] , Public Address System Trainer Kit [To Test The Performance Of Loudspeaker And Microphone; Power Output: 100W Rms At 10% Thd Pre-Amplifier Output: 200Mv; Line Output: 1V/ 1K?; Input Channels: Mic: 2Nos; Frequency Response : 65 Hz To 15 Khz +/- 3Db Tone Controls : Bass, Treble, Master 1Control; Speaker Outputs : 4 , 8 , 16 , 70-100V Line Matching; Speakers : 2 Nos; Microphones : 2 Nos(Dynamic Microphone)] , Demonstration Kit Of Black & White Tv Trainer [To Learn The Practical Aspects And Faults Which Would Occur Often In The Black And White Tv. All The Fault Switches Are Provided To Conduct Fault And Observe The Output. The Test Points Are Provided To Determine The Voltages At The Different Sections Of The Tv And Observe The Signal Output Of The Various Sections. The Output Is Monitored On A 20” Picture Tube.] , Demonstration Kit Of Colour Pattern Generator For Colour Tv [They Should Be Able To Make Various Patterns, Including Vertical Bar Patterns, Horizontal Bar Patterns, Circle Patterns, 100% White Patterns, Check Patterns, Horizontal Bar Patterns, Vertical Bar Patterns, Color Bar Patterns, Red Color Patterns, Green Color Patterns, Blue Color Patterns,Yellow Color Patterns, Magenta Color Patterns, And Cyan Color Patterns. Learning Materials To Be Included: Theory, Procedure, Reference Results, Etc.] , Demonstration Kit Of Colour Led Tv Trainer [Display Type: Led; Hd Screen Size: 24 Inch (50Cm) Or More; Display Resolution: 1600 X 900 Pixels Or More; Video Interface: Video Input/ Vga, Hdmi And Or Dvi Input; Audio Output Power: 8W X 2; Receiving System: Pal Bg/I/Dk And Ntsc; Channel Coverage: Vhf-2-12, Uhf21-69; Catv (X~Z+2, S11s41) Mains Supply: 110-260V Ac ± 10%, 50/60Hz; Power Consumption: 35W] , Demonstration Kit Of Dth Trainer Kit [Colour Tft Lcd: 5.7” Tft Lcd; Rf Input: 950 - 2150 Mhz; Rf Output: 470 Mhz Two 862Mhz; Video Output: Pal/Ntsc; Uplink Satellite: Insat 4B; Test Points: 34 Nos.; Included Accessories: Mains Cord, Power Supply, Remote, Dish Antenna With Accessories, Lnb] , Demonstration Kit Of Photocopier [Interface Hi-Speed Usb 2.0 Copy Speed Simplex To Simplex Up To 20 Ppm In A4 (21 Ppm In Letter) Scan Method Color Cis Compatibility Twain, Wia Fault-Creating Facilities For Crum, Thermistor, Stepper Motor, Pickup Clutch, Feed Sensor, Width Sensor, Scanner Stepper Motor, Scanner Sensor, And Printer Door. Various Fault Switch With Test Points Provided On-Board.] , Demonstration Kit Of Fully Automatic Washing Machine Trainer Kit [Semi/Fully Automatic Washing Machine Mechanical Controls 30 Minutes Timer, Wash/Spin Control Atleast 6 Liter Capacity Machine Fault Switches For Wash Motor, Spin Motor, Lid Opening, Buzzer Etc All Faults Are Mounted On Pcb With Enclosure] , Demonstration Kit Of Microwave Oven Trainer Kit [Type: Solo; Capacity: >15 Ltr; Power Consumption: 600 Watt Or More: Child Lock And Alarm, Various Test Points] , Demonstration Kit Of Refrigerator [Industry Standard Specification To Perform Relevant Experiments. ] , Demonstration Kit Of Air Conditioner. [Industry Standard Specification To Perform Relevant Experiments. ] , Tdmpulse Code Modulation Trainer Kit [Crystal Frequency: 12/16 Mhz On Board Generators, 1. Adjustable Amplitude Sine Generator Of 500Hz & I Khz (Synchronised) 2. Variable Amplitude Dc Level (2 Nos.) Input Channels: Two Multiplexing: Time Division Multiplexing Modulation: Pulse Code Modulation Sync Signals: Pseudo Random Sync. Code Modulation Error Check Code: Off, Odd, Even, Hamming Operating Modes: Fast 240 Khz Channel (Approx) And Slow I Khz Channel (Approx) Pc - Pc Communication: 2 Channel Via Rs 232 Baud Rate: Selectable From 300 To 2400 Fault Switches : 8 Nos. Through 8 Way Dip Switch For Troubleshooting At Different Blocks Should Include Various Test Points] , Tdm Pulse Code Demodulation Trainer Kit [2 Channel Time Division Multiplexed Pulse Code Modulation Receiver. Fast (240 Khz/Channel Approx) And Slow (1Hz. /Channel Approx.) Mode Of Operation Pseudo Random Sync. Code Generator For Frame Synchronization. Receiver Clock Generation Using Pll. Error Detection Of None, Even, Odd, Hamming. Error Correction Using The Hamming Code Technique None, Even, Odd, Hamming Parity Selections Two Nos. Of 4Th Order Butterworth Low Pass Filter With Cut Off Frequency Of 3.4 Khz. Four Switched Faults For Fault Selection Block Description Screen Printed On Glassy Epoxy Pcb] , Fdm Transmitter / Receiver Kit [Two Variable Modulating (Sinusoidal) Input Channels With Provision Of Voice Inputs Two Dsbsc Modulators For Frequency Band Translation Of Two Test Signals Two Carrier Generators Two Sets Of Audio Input Amplifier One Adder/Transmission Amplifier Two Demodulators Two Low Pass Filters For Smooth Output] , Ask / Psk / Fsk Modulation And Demodulation Kit [The Kit Should Have An Integrated Ask / Psk / Fsk Modulation And Demodulation. Various Functional Block Diagrams Are Provided On-Board For Teaching/Training. Test Points To Visualize The Signals On Oscilloscopes] , Microwave Test Bench (Klystronbased) [Complete Klystron-Based Test Bench Study Of The Characteristics Of The Klystron Tube And To Determine Its Tuning Range, To Determine The Frequency & Wavelength In A Rectangular Waveguide Working On Te 10 Mode, It Should Also Be A Ble To Study Characteristics Of The Directional Coupler, Attenuator And Isolator.] , Microwave Test Bench (Gunn Based) [To Study The V-I Characteristics Of Gunn Diode, To Study The Voice Communication By Using Microwave Test Bench, To Study The Following Characteristics Of Gunn Diode, It Should Also Be A Ble To Study Characteristics Of The Directional Coupler, Attenuator And Isolator.] , 24 Awg Tinned Single Strand Jumper Wire Spool Blue Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Green Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Red Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Black Colour [90 Meter Spool] , Flexible Electric Wire [2 Core, Twisted Flexible, Red And Black, 0.5 Sq Mm Copper Core, 50M Length] , Soldering Wire [Flux Core, Coil Type (Wire Of 100Gm )] , Inductor 1 Mh [8X10 Mm Radial Leaded Power] , Inductor 10 Mh [8X10 Mm Radial Leaded Power] , Led Red, Green, Blue, White Colour. Fifty Numbers Of Each Colour Led. [0.5W, Through Hole Type] , Ic 7400 [Ttl Ic-Quad 2-Input Nand Gate] , Ic 7402 [Ttl Ic-Quad 2-Input Nor Gate] , Ic 7404 [Ttl Ic-Hex Inverter Gate] , Ic 7408 [Ttl Ic-Quad 2-Input And Gate] , Ic 7432 [Ttl Ic-Quad 2-Input Or Gate] , Ic 7486 [Ttl Ic-Quad 2-Input Xor Gate] , Ic 7474 [Ttl Ic-Dual D Positive Edge Triggered Flip-Flop, Asynchronous Preset And Clear] , Ic 7476 [Ttl Ic-Dual J-K Flip-Flop, Asynchronous Preset And Clear] , Ic 7490 [Ttl Ic-Decade Counter (Separate Divide-By-2 And Divide-By-5 Sections)] , Ic 7495 [Ttl Ic-4-Bit Shift Register, Parallel In, Parallel Out, Serial Input] , Ic 74200 [Ttl Ic-256-Bit Ram (256X1)] , Ic 74147 [Ttl Ic Encoder] , Ic 74138 [Ttl Ic 3 To 8 Line Decoder] , Ic74151 [Ttl Ic Multiplexer] , Ic74138 [Ttl Ic Demultiplexer] , Ic 74169 [Ttl Ic Up-Down Counter] , Ic 74180 [Ttl Ic Parity Checker/Generator] , Ic 74Ls83 [Ttl Full Adder With Carry Ic] , Ic 74330 [Ttl Ic-Pla (12 Inputs, 50 Terms, 6 Outputs)] , Ic 4077 [Cmos Ic Xnor Gate] , Ic 4001 [Cmos Ic Nor Gate] , Ic 4011 [Cmos Ic Nand Gate] , Ic 4070 [Cmos Ic Exor Gate] , Ic 4071 [Cmos Ic Or Gate] , Ic 4077 [Cmos Ic Ex-Nor Gate] , Ic 4081 [Cmos Ic And Gate] , Ic 4093 [Cmos Ic Nand Gate] , Ic74ls47 [Bcd To 7-Segment Decoder/Driver Ic (7447 Ic) Dip-16 Package] , Lts542 [7-Segment Display - Common Anode] , Lts543 [7-Segment Display - Common Cathode] , Ic Dac0808 [Dac0808 8-Bit Digital To Analog D/A Converter Ic Dip-16 Package] , Ic Adc0809 [Adc0809 8-Bit A/D Converter With 8-Channel Multiplexer Ic Dip-28 Package] , Ic723 [Voltage Regulator Ic Input Voltage Up To 40V Output Voltage Adjustable From 2 To 37V Positive Or Negative Supply Operation Series, Shunt, Switching Or Floating Operation Output Current To 150Ma Without External Pass Transistor Adjustable Current Limiting] , Icl8038 [Function Generator Ic Wide Frequency Range - 0.001Hz To 300Khz Variable Duty Cycle - 2% To 98% High Level Outputs - Ttl To 28V Simultaneous Sine, Square, And Triangle Wave Outputs] , Ad633 [Analog Multiplier Ic 4-Quadrant Multiplication Low Cost, 8-Lead Soic And Pdip Packages Complete—No External Components Required Laser-Trimmed Accuracy And Stability Total Error Within 2% Of Full Scale Differential High Impedance X And Y Inputs High Impedance Unity-Gain Summing Input Laser-Trimmed 10 V Scaling Reference] , Lm566 [Vco Ic Wide Supply Voltage Range: 10V To 24V Very Linear Modulation Characteristics High Temperature Stability Excellent Supply Voltage Rejection 10 To 1 Frequency Range With Fixed Capacitor Frequency Programmable By Means Of Current, Voltage, Resistor Or Capacitor] , Ic Ne555 [Ne555 Timer Ic Dip-8 Package, Pack(Set) Of 30 Ics] , Ic 741 Op-Amp (Dip) [741 Ic - Dip Package - General Purpose Op-Amp Ic, Pack(Set) Of 50 Op-Amps] , Transistor 2N3904 [Pack (Set) Of 20 Transistors] , Transistor Bc107b [Pack (Set) Of 20 Transistors] , Diode 1N4007 [Pack (Set) Of 50 Diodes] , Fet- Bfw10 [Pack (Set) Of 50 Field Effect Transistors] , Zener Diode 5.6V, 1W [Pack (Set) Of 20 Zener Diodes] , Potentiometer 1 K?, 10 K?,100 K? Power Rating: 1W [20 Nos Of Each Value] , Wire Stripping Pliers, 6 Inch Long [Stainless Steel, Rust Resistant.] , Long Nose Mini-Pliers [Stainless Steel, Rust Resistant.] , Resistor 33O, 56O, 68O, 82O, 100O, 120O, 200O, 220O, 270O, 330O, 390O, 470O, 680O, 1K?,1.5K?. Maximium Power Rating 1/4W [Pack(Set) Of 50 Nos Of Each Resistor Value] , Resistor 2.2K?, 2.7K?, 3K?, 4.7K?, 5.6K?, 6.8K?, 8.2K?, 10K?, 20K?, 36K?, 56K?, 68K?, 100K?, 470K?, 1M?, 2M? Maximium Power Rating: 1/4W [Pack(Set) Of 50 Nos Of Each Resistor Value] , Disk Ceramic Capacitor Of Values 220 Pf, 0.01 ?F, 0.024?F, 0.1?F, 0.24?F [Pack(Set) 25 Nos Of Capacitors For Each Valueh] , Disk Ceramic Capacitor Of Values 10?F(63V), 100?F, 220?F, 470?F(50V) [Pack(Set) Of 25 Nos Of Capacitors For Each Value] , Polypropylene Capacitor Of Values 0.001 ?F,0.01 ?F, 0.1 ?F, 0.22 ?F [Pack(Set) Of 25 Nos Of Capacitors For Each Value] , Tantalum Capacitor 10 ?F (25 V) [Pack(Set) Of 25 Capacitors] , Incandescent Bulb, 40W, 100W, 200 W [With Tungstenfilament And B22 Connector]
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 10
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Uttar Pradesh View Result →
6.
Power #10781457 Price Bid
CONSTRUCTION OF 33 KV TRANSFORMER BAY FOR6.3 MVA 33/11KV, POWER TRANSFORMER INCLUDING ITS CIVIL FOUNDATION WORK,ERECTION TESTING AND COMMISSIONING AT 33/11KV SUBSTATION AT RAMGARH.ON TURNKEY BASIS- 1 SUB-STATION MAIN EQUIPMENT 2 33kV Vacuum Circuit Breaker (36kV,1250A,26.2 kA,Outdoor type) 3 33 kV Isolator without Earthing Blade (36kV, 1250A, Outdoor, 3 poles, 25 kA) 4 33 kV Current Transformer (33 kV, 10, Multi Ratio Multi Core, Outdoor) (1 No. per ) 5 33 kV lightening arrestor (33kV, 1phase, Core Outdoor )(1 No. per ) 6 33kV C&R Panel along with O/C, E/F relays and differential relays , mimic diagram,Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port suitable for transformer protection 7 33 kV Polymer Post Insulator 36kV,170kV Impulse, creepage distance 1224m 8 11kV Incomer VCB Panel (to Match with existing 11kV Stelmecmake feeder panels) 9 630mm²1 Core Power Cable 11kV XLPE 10 GANTRY STRUCTURES 11 Steel Structures 12 Galvanised Nuts & Bolts 13 Redoxidepaint for Gantry structures (Existing and new) 14 Aluminium paint for Gantry structures (Existing and new) 15 CONTROL CABLES 16 12 Core 2.5 mm² Control cable copper Armoured, 1.1 kV Grade, ISI, FRLS. 17 6 Core 2.5 mm² Control cable copper Armoured, 1.1 kV Grade, ISI, FRLS. 18 2 Core 2.5 mm² Control cable copper Armoured, 1.1 kV Grade, ISI, FRLS. 19 iv) Lugs, Ferrules etc. 20 CONDUCTOR & HARDWARE 21 i) 200 mm² ACSR Conductor Panther 22 ii) T Clamps/C.T clamp/LA clamp/VCB clamp 23 iii) Aluminum Bus Bar(75x10mm for power transformer ) 24 iv) Cable kits suitable for 630mm²1 Core Power Cable 11kV XLPE (Both indoor and outdoor type) Denson/3M/Raychaim make 25 Civil works for transformer equipment foundation and gantry foundation as per approved design 26 Erection testing and commisioning of 6.3 MVA,33/11kV power transformer available at site
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
8.
Power #10774240 Price Bid
Tender For Annual Rate Contract For Supply Of Spares Of M/S Elgi Make Air Compressors For Various Power Plants Of Rvun I.E. Ctpp-O&M, ,Chhabra, Ctpp-Sc, Chhabra, Stps(O&M), Suratgarh ,Stps-Sc, Suratgarh, Ktps, Kota, Katpp, Jhalawar, Dcpp, Dholpur - Mechanical Items 2 107315-EXPANSION VALVE (B740104) Part No.B000500010111 3 115014-COMPRESSOR MTZ125(B680111) Part No.B000500010077 4 24V DC SOLENOID VALVE Part No.10450200 5 90 Deg Elbow CPLG-E18-E22 Part No.B004700770016 6 9BD 1/4 BSP 12 68 GIMC PG Part No.B212311 7 A/E PKG, 225 TRB GR:2, VI3.6 Part No.X990463 8 ACTUATER ASSLY.(Without Diapharam Type) Part No.B011501070001 9 ACTUATOR REPAIR KIT HB Part No.B009401070011 10 ACTUATOR REPAIR KIT WITH SPRING Part No.B015401070005 11 ADAPTER NUT PRESSURE SWITCH Part No.10461090 12 After Cooler Assembly Part No.01034469B 13 After Cooler Assy Part No.15302436 14 After Cooler Assy SS20 Part No.B011301290007 15 AIR END Assy Part No.X019259 16 AIR END ASSLY E-37 Part No.X039106 17 AIR END ASSY (E-160-5.5) Part No.X990500 18 Air Filter ASS F6 Open Type Part No.B004700770036 19 Air Filter Element 90 TO 132 Part No.B574609 20 AIR FILTER ELEMENT (1390 CFM) Part No.B005700730003 21 Air Filter Element 10S - Horizon Series E11/15 Part No.B574603 22 Air Filter Element 12S Horizon Series - New Part No.B574604 23 Air Filter Element EG18-22 Part No.B005700770005 24 ANTI VIBRATION MOUNT PAD PC 140 C (Air End) Part No.B141433 25 Anti Vibration Mount PAD Pc 182b (Motor Side) Part No.B141429 26 Auto Drain Float Type Part No.B001305630001 27 AUTO DRAIN VALVE KIT F5 & F6 B000306040013 Part No.B001302940001 28 AVM (ANTI VIBRATION MOUNT) NO.2 NH1X Part No.41041X020 29 B D V Assy (E132)1/2 Part No.A010029 30 BDV Kit - E1320-37-45 HOR Part No.220371089 31 BDV Kit (Service Kit for VVF15) Part No.B009401070003 32 BOLT HEX M10X45 8.8 ZBP 5-8M Part No.906148 33 BREATHER VALVA ASSLY. A020030 Part No.411380 34 Bush ADOPTOR REDUSOR 5/8 Part No.10461030 35 CHECK VALVE Part No.B004101070001 36 CHECK VALVE ASSLY DELY Part No.41031X006 37 Circlip Internal 20mm 100 Dia Part No.917220 38 COLLER LUBE OIL Part No.41041X014 39 CONNECTOR HOSE ADOPTOR 1/2 Part No.22343137C 40 Connector Rubber CCVA-Duct Part No.410420006 41 Connector Set FOR NEURON II Part No.00897903R 42 COUPLING ROTEX-28 Part No.B005400590005 43 Coupling TMS 1/4 x 1/4 T Part No.22047683A 44 Coupling TMS 1/4X1/8 NPT Part No.22047683P 45 Cylinder 100 Dia - Disc Valve Type Part No.00021010A 46 D/v Packing Small DIA 100 Part No.519220 47 Dia 150 Suction Hose WIT Endcuff Part No.B010306260001 48 DIFFERENTIAL PR. (OIL FILTER) Part No.B010700770001 49 DIFFRENTIAL PRE.SWITCH (SEPARATOR) Part No.B221901 50 DISC VALVE ASSLY. DIA .60 CYL A070017 Part No.313810 51 Disc Valve Assy 100 Dia A020569 Part No.A020042 52 DISC VALVE GASKIT SMALL 60 DIA D/V Part No.524070 53 Disc Valve Repair Kit 100 Dia Part No.22400989 54 DISCHARGE HOSE AIR END TO OIL TANK E-160-5.5 Part No.15301622 55 DISCHARGE HOSE AIR END-OIL TANK E132-5.5Part No.15303514 56 Drive Coupling 60/40.430 - E37-HOR Part No.B545922 57 Drive Coupling Bore 48/38.115 Part No.B545902 58 DRIVE COUPLING DIA 80/60 Part No.B548313 59 Drive Coupling Element Rotex 48 - EG37-45 Part No.12437520 60 DRIVE COUPLING INSERT Part No.B005401170007 61 Elbow TMS 1/4 X 3/8NPT Part No.22047681C 62 ELBOW 37FL/90M 7/8UNFX1/2NPT Part No.22343136C 63 ELBOW TMS 1/4 X 1/4 Npt Part No.22047681B 64 Element Filter B Type Part No.317820 65 ELEMENT SEPARATOR Part No.10350060 66 ELEMENT SEPARATOR (E160-5.5) Part No.B677701 67 ELEMENT SEPARATOR E-132-5.5 Part No.10454350 68 ELGI Air Lube UT OIl 208 LTR 998103 Part No.998069 69 ELGi Air Lube XD - 210 Ltr 998121 Part No.998055 70 EMERGENCY SWITCH/STOP Part No.8940030 71 FILTER AIR INTAKE Part No.410420001 72 GASKET BIG CYL TO D/V DIA100 Part No.519210 73 GASKET MIST SEPARATOR Part No.415400383 74 GZHD- Automatic Drain Valve(B130101) Part No.B001303900001 75 HEX NIPPLE 1/4 Npt Part No.22037903A 76 HEX. Nipple 1/2x14 NpT Part No.220370540 77 High Sump Pressure Switch (INDFOSS) Part No.B182011 78 HINGE- M8-(DHFM-60) Part No.41041X287 79 HOSE - 1 1/4 OIL COOLER OUT Part No.15303928 80 Hose - 1 1/4In Oil Cooler In Part No.15302546 81 Hose 1-1/4 OIL COOLER TO OIL FILTER INLET Part No.10445060 82 Hose 1-1/4 Oil Injection 015310983 Part No.15304655 83 HOSE ASSLY 1 1/4( OIL FILTER-OIL TANK) Part No.10343270 84 HOSE ASSLY 1/2X1000 Part No.15400998 85 HOSE ASSLY OIL FILTER-AIR END ASSLY 132-5.5 Part No.15400154 86 HOSE ASSLY. ( OILFILTER-AIR END ) Part No.10450470 87 Hose Assy (Mpv After Cooler) Part No.15301628 88 HOSE Assy . 32 NB (Metalic Elbow) E110-100 OUT LET Part No.10445120 89 HOSE WITH METALLIC BELLOW Part No.10450520 90 HOSE WITH METALLIC BELOW 50NB Part No.15400624 91 INTAKE VALE ASSY (E 160-5.5) Part No.B009801070010 92 Intake Valve Kit (NC 3) Part No.10331209 93 Intake Valve Assly- Nc 3 E30-37, Horizon Part No.B009806750002 94 Intake Valve KitE-132-5.5 Part No.10331109 95 INTAKE VALVE KIT (E-160-5.5) Part No.B009401070004 96 Intake Valve Kit 3 - E30-45 HOR - 12S Horizon Part No.10331219 97 Intercooler Assly SS20 Part No.B011301290006 98 KIT - TUBES & ACCESSORIES OA2 Part No.412400534 99 KIT AIR PIPING OA2 Part No.412400531 100 KIT CCVA OW2 Part No.412400502 101 KIT DISCHARGE VALVE RR80/3CDB Part No.72403739 102 KIT LUBRICATION PIPING OA2 Part No.412400532 103 KIT OIL FILTER Part No.10440229 104 Kit, Gasket and Sealing Part No.72403419 105 KIT, SPARES, 1 YR TRC2507 Part No.72403399 106 LOW WATER PRESSURE SWITCH (DANFOSS) Part No.B185103 107 M P V KIT E-132-160-5.5 Part No.B009301070004 108 MINIUM PRESSURE VALVE 1 1/4 Part No.22021052A 109 Mist Seperator NH20_NH31 Part No.410420133 110 Moisture Separator MS150 Part No.A010103 111 MPV KIT ( with Check Valve MPVL 65F) Part No.B009301070012 112 MPV with Check Valve - MPVL80F Part No.B009301070009 113 MPV WITH CHECK VALVE- MPVL65 Part No.B009301070003 114 Multi Tap Transformer - 50VA (400/24V) Part No.8937046 115 Neuron-II Controller PLC Part No.00897701N 116 NRV Assy 1/4 ROCD Part No.B441701 117 O/C (oil cooler) and A/C (After cooler)Assy WC 100-180HP Part No.10344690 118 Oil Cooler & After Cooler Assy Part No.B007700690004 119 Oil Cooler Assy Part No.15302437 120 OIL COOLER ASSY. (E-160) Part No.01034469A 121 Oil Filter - SpinOn - E/EG11-75 Part No.B004800770001 122 OIL FILTER ELEMENT 180 LPM ( E-90,110,160) Part No.B407701 123 OIL FILTER HEAD ASSLY. 360LPM Part No.15303640 124 Oil Sight Glass 1 1/2 Bsp 1500-400 Part No.15306517 125 OIL Sight Glass 11/2NPT Part No.A010018 126 O-RING ID 47.2X3.5 Part No.10451500 127 O-RING ID 80.0X3 Part No.15402871 128 O-RING ID69.4X3.5 Part No.15402687 129 Pipe Assy Contg No. 2 Ss15ts 10 Part No.334010 130 Pipe Assy Contg No.3 Ts 10/12 Part No.334020 131 PIPE ASSY.WATER LINE Part No.10445130 132 PIPE CONNECTOR PCDIN 32 Part No.B005604660007 133 PIPE CONNECTOR PCNB 100 VITON Part No.B005604660012 134 PIPE COUPLING 1 1/2 STY12 Part No.B56XX07 135 Pipe Ret Line 20/16 Tandem Part No.10454710 136 Pipe Return Line Part No.15301053 137 Piston Assy Dia 60 TS / HP(TRC1000) Part No.413120 138 Pkg Big Dia 60 D/V (TRC1000)MN Part No.524060 139 Plastic Tubing Dis 10*1.5 Blue Part No.919242 140 Plug Hex 3/4 Bsp HV20/25/30 Part No.510740 141 Pr Transmeter 16 Bar E75-160 Part No.00897901c 142 Pr. Regulator Aircon Part No.B158002 143 Pr. Regulator Aircon Kit PR934 Part No.B158004 144 PR. SWITCH KP 36 ( 2 TO 14 BAR) Part No.B001800510002 145 PRESSURE REGULATOR Part No.B001501070001 146 Pressure Regulator (PRNE 1.2mm) Part No.B001501070002 147 Pressure Relief Valve Part No.B012806660008 148 Pressure Relief Valve Assy 1/2 Part No.A010019 149 PRESSURE RELIF 1 VALVE ASSLY Part No.B012806660001 150 Pressure Transmitter 0-16 Bar M Part No.00897902N 151 QUICK FITTING ELBOW 3/8-10(PART NO.920609) Part No.920611 152 Reverse Rotation Switch Part No.8941151 153 Rubber Elbow 8x7 Part No.220375380 154 Safety Valve 90-132 Kw 13 Bar Part No.B012806160003 155 Seal Oil B50*72*12 Trc 1000B Part No.420360 156 Separator Element 12S Hor - E30-45 Part No.10451050 157 SHUTTEL VALVE (E-132) Part No.B011001070001 158 Silencer Blow Off NH1X Part No.410320149 159 SLEEVE FOR 6X4 MM TUBE Part No.959763 160 Sleeve, Gearcase Side NH20 Part No.410420118 161 Solenoid Value 240VAC NO E30-37-45 HOR Part No.B738207 162 SOLENOID VALVE 220V A/C Part No.B007300990007 163 SOLENOID VALVE 110V - NH42 Part No.B007300820001 164 SOLENOID VALVE 240 V NC Part No.B738208 165 SOLENOID VALVE NC 24V 50HZ Part No.B007300990004 166 SOLONEID VALVE ASSLY 4 WAY Part No.B73XX04 167 STAND PIPE ADOPTOR 1/4 Part No.15400598 168 STAND PIPE ADOPTOR 1/8 Part No.15400702 169 Strainer Oil NH1X Part No.41041X019 170 TEE MALE Part No.10445040 171 TEE PIPE 1/2 NPT Part No.22047680C 172 Tee Pipe 1/4 Part No.22047680A 173 TEE Run Taper MALE 1/4 Part No.22037106A 174 TEE; BRANCH; TM; 1/4X1/4NPT Part No.22047682A 175 TEMP. CONTROLLER-172808B009400010260 Part No.B710101 176 Temp. Sencer 0-150 Part No.00897902C 177 Temperature Switch LE 150 Part No.B171901 178 Thermal Valve 155 Part No.220322920 179 Thermal Valve ELEMENT 125 F Part No.220310800 180 Thermal Valve Housing Part No.220377200 181 TRANSFORMER 30VA ELRD150-400 Part No.B008604850001 182 TUBE RETURN LINE - 1.7 Part No.10363080 183 TUBINGS 6MM Part No.920620 184 Valve Air Intake 6 Aircon Part No.A010106 185 Valve Assy Breather Aluminum Part No.A020030 186 Complete Overhauling Kit of ELGI make compressor Model No. SP20400 (Disp. Vol-1230 lpm) T/B FAB. No.- CKJT600003 Part No.022402139 187 WASHER, SPRING M10 Part No.996110 188 NUT HEX M10 Part No.948010 189 Airend Assy. X990357 Part No.X990068 190 TMS Elbow 1/4x1/4(TEE) 22047681B Part No.22047681D 191 Inter cooler Part No.216130 192 Valve assembly, safety 3/4BSP B841701 Part No.B8441701 193 Valve assembly, drain 1/4BSP Part No.A020045 194 Pipe assembly No. 1 Pressure line 70407340 Part No.445860 195 Pipe assembly No. 2 Pressure line 70407350 Part No.320930 196 Farul with nut 10mm Part No.220374440 197 After Cooler Part No.103469B 198 Hose MPV to Cooler Part No.15400319 199 Hose MOF to Airend Part No.15400923 200 Pipe Coupling 1 1/2 Part No.B55xx07 201 Pre Filter for Air Filter Part No.B015403266 202 Anti Vibration Mount Pade (Airend & Motor Side) Part No.B001406190004 203 Oil Return Line Part No.15403077 204 Oil Sight Glass 1/8 Part No.B004606240001 205 BDV assy (E160.5.5) Part No.A010029 Part No.B00940107003 206 MPV KIT-10S-1-1/4-e30-37-45 HOR Part No.220210529 207 Air end return line fittingPart No.JLKI 208 Air End Assembly X990484 Part No.X990484 209 Rubber Reducer Part No.015305798 210 RDS mounting connector Part No.015403668 211 Air Filter Life Indicator Part No.B012400770001 212 1/4 BSP Straight fitting Part No.B009606780009 213 Run Tee 1/4 Part No.B009606780017 214 Multi Tap Transformer (500VA) Part No.0008937081 215 Multi Tap Transformer (100VA) Part No.0008937071 216 Thermistor Controller Part No.018362741 217 Single Mode Power SupplyPart No.B012701600041 218 Kit inlet valve Assembly Installed on Cylinder Head Part No.72403729 219 Oil Return Line Assembly Part No.15401395 220 Compressor Emerson / Danfoss 115895 KCM 5191512040422 Part No.B000500010121 221 Fan Motor1820031512040223Part No.B760103 222 Old Description & Part No.DRIER FILTER(Part No. B690101)New Description & Part No.:-225205-DRIER FILTER 0605010067 Part No.B006900010006 223 Condenser (Cooler) for ELRD 1254W0603000081 Part No.B000500010141 224 Kit Check Valve Part No.41041X032 225 GASKETKIT GEARCASE Part No.410420012 226 SEAL KIT OIL PRESSURE RELIEF VALVE Part No.41041X035 227 KIT CAPACITY CONTROL VALVE/ Gasket water pipe Part No.410420010 228 DISC COUPLING SM 220 Part No.B005401050012 229 SPACER MOTOR SIDE Part No.410420159 230 LEG MAIN MOTOR Part No.41031X197 231 INDICATOR OIL LEVEL Part No.41041X028 232 DIFFUSER ASSEMBLY Part No.410420174 233 PRESSURE RELIEF VALVE ASSEMBLY Part No.41031X007 234 RELIEF VALVE OIL PRESSURE Part No.B15XX01 235 SWITCH BLOW OFF PRESSURE Part No.B182010 236 PLASTIC TUBING DIA. 12 X 2 BLUE Part No.919252 237 PLASTIC TUBING DIA. 12 X 2 BLUEcorrected as DIA 6X1 BLU Part No.919226 238 Quick Fitting Elbow 1/4-10 Part No.920606 239 Quick fitting Connection 1/4-10 Part No.920506 240 Quick fitting Connection 3/8-10 Part No.920509 241 Quick fitting Connection 1/2-12 Part No.920512 242 PUMP LUBE OIL Part No.B12XX01 243 SHAFT WITH BULL GEAR,PINION GEAR Ist STAGE,PINION GEAR 2nd STAGE Part No.A410057 244 AIR BLOCK 1st STAGE Part No.A410053 245 AIR BLOCK 2ndSTAGE Part No.A410054 246 HOT GAS BY PASS VALVE Part No.B750101 247 HIGH PRESSURE SWITCH Part No.B180101 248 LOW PRESSURE SWITCH Part No.B180102 249 Quick Fitting Elbow 1/2-12 Part No.920612 250 Reducer (1 X 1 1/2 ) Part No.22037901G 251 Manifold 1/4Part No.10460950 252 S S T Bolt Clamp DIA-199 Part No.B505304 253 S S T Bolt Clamp DIA-225 Part No.B505305 254 Airend Assy (E160-5.5) Part No.X990060 255 Elbow Male 11/2 X 11 / 2 Part No.10445030 256 TMS Couplng 1 1/2 X 11/2 22047683K Part No.220476200 257 Complete Overhauling Kit of ELGI make compressor Model No. THPC500(Disp. Vol-500 lpm) T/B FAB. No.- 66459 Part No.X020012A 258 Kit disc valve assy. 60DA070017 Part No.72400980 259 Intake Valve Assly. 3 E-30-45 NO B009806750002 Part No.A010270 260 Display PCB E-15 Part No.10866219 261 Separator Element 12S Hor - E30-45 317 CFM Part No.10451060 262 Kit Tune Up - TS07HN Part No.K0206101 263 Cylinder 100 Dia - SS07H Part No.00021010D 264 Cylinder 60 Dia - TS05/07 -NH Part No.210110 265 Piston W /Gudgen Pin 100 Dia Part No.20494560 266 Kit Piston/GP /Circlip 60 Dia -TS Part No.22455969 267 Cylinder Head 100 Dia TS05/07H Part No.00021238C 268 210120 Cylinder Head 60 Dia TS07HN Part No.210120 269 Con Rod Crank Shaft Assy W/Brg - TS07HN Part No.20362530 270 Gasket Free End Cover SS07/10 Part No.425460 271 Gasket Fly End Cover SS07/10 Part No.425470 272 Oil Seal TS 05/07/10/15, SS 07/10 Part No.420350 273 Rubber Beading Part No.432330 274 Oil Level Indicator 1 1/4BSP Part No.513440 275 Valve Flat 100 Dia TS/ SS Part No.310070 276 Valve Flat 60 Dia TS07HN Part No.310080 277 KIT PR.SWITCH RETROFIT TS 220 Part No.22458379 278 FILTER ASSY I/L AIR B TYPE Part No.A020024 279 SV ASSY 1/4BSP 14KSC TS Part No.A020196 280 HOSE ASSY PVC& WIRE SS03/TS03NZ Part No.A020216 281 HOSE ASSY PVC&WIRE SS03/TS03NZ Part No.A020217 282 SV ASSY ? INCH BSP 16.2 KSC TS Part No.A020241 283 NRV AND CONNECTOR ASSY Part No.A020559 284 KIT PR. GAUGE RETROFIT TSLB Part No.22459279 285 VALVE ASSY BALL 3/4BSP Part No.B312716 286 VALVE ASSY BALL 3/8BSP Part No.B312725 287 RAC UNIT TS07 HN 100X60 Part No.X020758 288 A/C PIPE B/D TS07HN NEW FITT Part No.20365650 289 PR PIPE LINE ASSY 220L Part No.20496930 290 STARTER DOL 7.5 HP 415V Part No.518901530 291 117201-HAND SHUTOFF VALVE Part No.B011000010001 292 350 Dia Sucker Fan - 60 Hz Part No.18400036 293 Actuator Kit (W/0 Diapragm) Piston Type - F4 (B015401070005) Part No.B009401070008 294 ACTUATOR SPRING PISTON TYPE (B015401070005) Part No.B015001070001 295 ADAPTER FOR TEMP SWITCH Part No.30449400 296 Adapter Inlet Part No.15400589 297 Air End (132-5.5) X990462 Part No.X990030 298 AIR FILTER ASSY E37 Part No.B476702 299 AIREND PKG 2.70:1 E10 2BOLT FL Part No.X019255 300 ANN PCB ASSLY EPSAC Part No.8766219 301 Auto Drain Valve Internal - F2 - EG11-22 B001305630001 Part No.B001305480003 302 C/R Con Rod Crank Shaft Assy WB - TRC1000B Part No.70301130 303 CIRCLIP INTERNAL 18 MM Part No.917218 304 CONE ERMETO 1 BSP (000419240) Part No.00041924A 305 CONROD&C/SHAF ASSY;W/B TRC2507 Part No.70301140 306 CONTROL LINE TUBE E 30 Part No.15303179 307 Cyl Dia 60 D/v M/c TRC 1000 MN Part No.00021011A 308 DAMPENING PIPE ( INTER COOLER) Part No.428190 309 DISC VALVE ASSY DIA 100 (MODI) Part No.A020569 310 DISCHARGE PIPE ASSLY Part No.15303515 311 Ermeto, 3/4X1 BSP (00041017A) Part No.410170 312 FILTER ASSLY - OIL BATH - TS/SS (A070009) Part No.A070009 313 FILTER UNIT (184X184) Part No.18400062 314 Gasket 0.8 C/case to Cyl Bp 07/10 Part No.00041004C 315 Gasket Fly End S 10 Part No.431980 316 Gasket Free End TS 10 Part No.431990 317 GASKIT 0.4C/CASE TI CYL TS05 Part No.00041004B 318 GASKIT CYL TO CYL HEAD Part No.445610 319 HEAD DIA127 M/C HV Part No.215150 320 HOSE DISCHARGE (AIR END TO OIL TANK) Part No.15310767 321 Hose 1-1/4 Oil Injection 015402283 Part No.15304655 322 Hose 1-1/4 Oil Injection (000959438) Part No.15304655 323 Hose 1-1/4 Oil Injection (015305799) Part No.15304655 324 HOSE ASSLY TV TO O/C KIT-F5F6WC Part No.12473579 325 HOSE ASSLY. MPV TO A. COLLER EE 160-110 Part No.15300312 326 HOSE ASSY OC TO TV KIT- F5F6 WC Part No.12473589 327 HOSE ASSY 1/2 IN BDV E 90-110 Part No.15401740 328 HOSE ASSY O/C TO TV F5F6 WC Part No.15307093 329 Hose Assy Tank to MPV Kit - F6 WC Part No.12473609 330 HOSE ASSY TV TO A/E KIT-F6 WC Part No.12473629 331 HOSE ASSY- TV TO AIREND F6 WC Part No.15307355 332 HOSE ASSY. TV TO OIL COOLER WC Part No.15307092 333 HOSE ASSY.Tank to MPV F6 WC Part No.15307356 334 HOSE MED. PR. 1/2X32 Part No.22032027H 335 HOUR TOTALIZER H 57-55 24 V AC Part No.8938031 336 Intake Valve Kit Part No.B009401070009 337 KEY WOODRUFF Part No.420440 338 KIT IC MOS OA2 Part No.412400530 339 MIMIC PCB EPSAC WITH 0.5 M CABLE Part No.8766234 340 MULTI TAP TRANSFORMER 50 V Part No.8937048 341 NUT ERMETO 1 BSP (00041928A) Part No.419280 342 NUT HEX M10 8 ZBP Part No.948010 343 OBS PISTON RINGS DIA 197 Part No.22401079 344 OBS Piston Rings Dia127 TRC250 Part No.72403479 345 OBS PISTON RINGS DIA60 Part No.22401039 346 Oil and After Cooler Assy Part No.15307125 347 OIL FILTER ASSLY E-110 (015303640) Part No.B487702 348 PISTON & GP DIA60 TS05/07 Part No.477730 349 Piston Assy 100 Ss/TS 07 10 15 (TRC1000) Part No.413110 350 Piston Assy 127 HV TRC2507 Part No.428900 351 Piston Assy 197 HV20/25TRC2000 Part No.445850 352 Piston Ring Set Dia 100 MNUG (TRC1000)(022401059) Part No.72404039 353 Piston Ring Set Dia 60 MNUG (TRC1000) Part No.72404049 354 PRESSURE GAUGE 0-16 KG Part No.B212110 355 PRESSURE TRANSMETER 1TO6 BAR Part No.8979024 356 Rubber Elbow 4 16 S Part No.220375400 357 RUBBER PIPE BEND ID 76 Part No.B906701 358 Safety Valve 3/4BSP 6.5Bar Part No.B841701 359 Safety Valve 3/8 Bsp Part No.A020002 360 Seal Oil 85x110x13 Nh1 x Part No.41041X017 361 SPLIT COOLER E-37 Part No.B007700690010 362 STAINER ELEMENT 6CD 3UC Part No.325520 363 STUD M12X45 C/CASE TO 50CYL Part No.514560 364 STUD M12X54 60CYL Part No.514550 365 STUD M12X70 SS02/03/05 TS02/03 Part No.518830 366 Temperature Gauge 40-125 Part No.B202101 367 THERMAL VALVE BLOCK-F5 & F6-MA Part No.15305128 368 VALVE ASSLY .PRESSURE RELIF 1 Part No.A010107 369 Valve Assy Disc Dia60 Part No.A070017 370 WASHER CU HEAD TO CAP NUT Part No.439270 371 WASHER SPRING REC SEC M10 ZBP Part No.996110 372 WATER SEPRATOR W/O DRAIN 21/2 Part No.B000306040010 373 Drive Coupling Insert UCW 295 Part No.B05401170007 374 Stud M16x60 crank case and cylinder Part No.465300 375 Ring,spacer-bearing Part No.471280 376 Bearing,ball ,single row SKF 6310 Part No.903361 377 Gasket -free end cover Part No.445570 378 Cover free end Part No.329170 379 Gasket-fly end cover Part No.445880 380 cover ,fly end Part No.329150 381 washer spring M12 Part No.996112 382 Bolt hex M12x40 Part No.906185 383 Gasket -crank case to dia 197 cylinder 0.75mm Part No.445600 384 Gasket -crank case to dia 197 cylinder 0.4mm Part No.00044560A 385 Cylinder dia 197 Part No.320920 386 Washer spring M16 Part No.996116 387 Nut hex M16 Part No.948016 388 Gasket -crank case to dia 127 cylinder 0.75mm Part No.00042843A 389 Gasket -crank case to dia 127 cylinder 0.4mm Part No.00042843B 390 Gasket -crank case to dia 127 cylinder 0.2mm Part No.00042843C 391 Cylinder dia 127 Part No.214670 392 Head, dia 197 cylinder Part No.216100 393 Bolt , Hex, M16x110 dia 197 cylinder head Part No.906226 394 Gasket dia 127 cylinder to cylinder head Part No.440680 395 Bolt , Hex, M12x110 dia 127 cylinder head Part No.906197 396 Washer copper -inlet and discharge valve Part No.439260 397 valve assembly inlet Part No.A070072 398 Valve asssmbly discharge Part No.A070071 399 Plug inlet valve Part No.319290 400 Plug discharge valve Part No.319300 401 Valve assembly suction unloader Part No.A070073 402 Nut cap Part No.439280 403 Nipple hex 1x1 BSP Part No.432090 404 Elbow 1 BSP Part No.972055 405 Pipe 1 BSP breather Part No.438460 406 Socket 1 BSP Part No.20484920 407 Ring packing,Drain plug Part No.521960 408 Plug assembly, drain 1/2 BSP Part No.A020034 409 Ring, packing,dipstick Part No.474750 410 Dipstick with chain Part No.70400730 411 Gasket,dia 197 cylinder head to suction bend Part No.445730 412 Bend, suncton Part No.320790 413 washer spring,1/2 Part No.996205 414 Gasket air intake strainer to dia 197 cylinder head flange Part No.445730 415 Strainer with mounting flange,air intake Part No.330880 416 Gasket,Dia 197 cylinder head flange Part No.445730 417 Gasket,Dia 127 cylinder head flange Part No.445330 418 Bolt, hex, M10x40 Part No.906147 419 Key word ruff Part No.70401790 420 Cooling fan and Pulley assembly Part No.A070077 421 Washer Part No.70400150 422 Nut, castle M16x1.5 Part No.400090 423 Pin split 1/4 Part No.965498 424 Gasket dia 127 cylinder head flange to del. Manifold Part No.445330 425 Manifold delivery Part No.330660 426 Plate dummy,Delivery flange Part No.471290 427 Gasket,delivery flange Part No.445330 428 Flange with pipe,delivery Part No.70400770 429 Air Filter Element Part No.41041x013 430 Inter cooler drain silencer Part No.410320150 431 DISCHARGE VALVE ASSLY.(MOD-A0700710)A070071 Part No.MOD-A0700710 432 SS T Clamp Part No.B013704300005 433 Scavenging Line Lube Part No.15316211 434 panel View PVP4002711-PK4 C5D Part No.8901019 435 Bolt,Hex 1/2 UNCx1.25 Part No.000907247
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
9.
Power #10656217 Price Bid
Augmentation / Renovation And Modernization Of 33 / 11 Kv Receiving Station Sunjwan From 2X1.5 Mva To 2X3.15 Mva Along With, Erection Of New 33 Kv Line ( 2Nd Source ) From 33 / 11 Kv, 3X10 Mva, Receiving Station Channi Himmat To Receiving Station Sunjwan, Stabilization / Strengthening Of Existing 33 Kv Line ( 1St Source ) And Other Allied Works Relating To Receving Station Mes Sunjwan, Jammu On Turnkey Basis- 1 Substation Main Equipment 2 33 Kv Transformer Bay & Single Bus 33 Kv Line Bay 3 33 Kv Vcb ( 36 Kv, 1250A, 26.2 Ka, Outdoor Type ) 4 33 Kv Isolator Without Earthing Blade ( 36Kv, 1250A, Outdoor, 3 Poles, 25 Ka ) 5 33 Kv Current Transformer ( 33 Kv, 1F, Multi Ratio Multi Core, Outdoor ) ( 1 No. Per F ) 6 33 Kv Voltage Transformer ( 33 Kv / 110 V, 1F, Multi-Core, Outdoor ) , ( 1No. Per F ) 7 33 Kv Lightening Arrestors ( 30 Kv, 10Ka, Station Class, Zno, Polymer ) Gap Less 8 33 Kv Polymer Post Insulator36kv, 170Kv Impulse, Creepage Distance 1224M 9 33Kv C&R Panel Along Witho / C, E / F Relays, Diffrential Relay, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps With Rs-485 Port, Dlms Compliant With Rs-485 Port ( For Power Transformers ) 10 33Kv C&R Panel Along Witho / C, E / F Relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps With Rs-485 Port, Dlms Compliant With Rs-485 Port 11 Steel Structures 12 Galvanised Steel Structures 13 Galvanised Nuts & Bolts 14 Conductor And Hardware 15 200 Mm² Acsr Panther Conductor 16 T Clamps 17 Tension Fitting Suitable For 200 Mm Sq Conductor. 18 33 Kv Polymer Composite Disc Insulators 36 Kv, Min Falling Load 70 Kn, Lightening Impulse 170 Kv Positive And 180 Kv Negative, Creepage Distance 900 Mm. 19 Earth Wire 7 / 3.15 Mm Sq. 20 Gi Flat For Earthing 50X6mm & 25X3 Mm 21 3.15 Mva , 33 / 11 Kv Power Transformer 22 33 / 11Kv, 3.15 Mva Onan, Copper Wound, Out-Door Type, Conventional Power Transformer, Oil Filled With Oltc And All Accessories Including Ht And Lt Terminal Connections 23 Power Control Cables And Accessories 24 12 Core, 2.5 Mm Sq. 25 6 Core, 2.5 Mm Sq. 26 4 Core, 2.5 Mm Sq. 27 2 Core, 2.5 Mm Sq. 28 Lugs, Ferrules Etc. 29 Laying Of 33 Kv Line ( Approximately 1.9 Km ) 30 13 Mtr. Long St Poles ( St-410Sp69 ) 31 G.I Channel ( 100X50x6 ) Mm Sq, G.I Angle ( 65X65x6 ) Mm, G.I Angle ( 50X50x6 ) Mm Sq. Sq., G.I Flat ( 50X6 ) Mm Sq. 32 200 Mm2acsr Panther Conductor 33 P.G. Clamp For 200 Mm2 Acsr Panther Conductor 34 33 Kv Pin Insulators Polymer Type ( 10Kn ) 35 33 Kv Polymer Composite Disc Insulators 36 Kv, Min Falling Load 70 Kn, Lightening Impulse 170 Kv Positive And 180 Kv Negative, Creepage Distance 900 Mm. 36 Tension Fitting Suitable For 200 Mm Sq Conductor. 37 Galvanised Nuts And Bolts With Washers 38 33 Kv Danger Plates With Clamps 39 Anti-Climbing Device With Clamps 40 Earthing Complete ( Gi Pipe 40 Mm Or Gi Rod 20 Mm, 2.5 Mtr Long With Gi Strip ) 41 33 Kv Isolatorwithout Earthing Blade 42 Red Oxide Paint 43 Aluminum Paint. 44 Cement Bottoming ( 1:2:4 Mix As Per Rec Standards, 6 Cum / Pole ) 45 Aluminium Jointing Sleeevs 46 Insertion Of 11 Mtr St Poles In Existing 33Kv Line 47 11 Mtr. Long St Poles ( St-410Sp56 ) 48 G.I Channel ( 100X50x6 ) Mm Sq, G.I Angle ( 65X65x6 ) Mm, G.I Angle ( 50X50x6 ) Mm Sq. Sq., G.I Flat ( 50X6 ) Mm Sq. 49 200 Mm2acsr Panther Conductor 50 P.G. Clamp For 200 Mm2 Acsr Panther Conductor 51 33 Kv Pin Insulators Polymer Type ( 10Kn ) 52 33 Kv Polymer Composite Disc Insulators 36 Kv, Min Falling Load 70 Kn, Lightening Impulse 170 Kv Positive And 180 Kv Negative, Creepage Distance 900 Mm. 53 Tension Fitting Suitable For 200 Mm Sq Conductor. 54 Galvanised Nuts And Bolts With Washers 55 33 Kv Danger Plates With Clamps 56 Anti-Climbing Device With Clamps 57 Earthing Complete ( Gi Pipe 40 Mm Or Gi Rod 20 Mm, 2.5 Mtr Long With Gi Strip ) 58 Red Oxide Paint 59 Aluminum Paint. 60 Cement Bottoming ( 1:2:4 Mix As Per Rec Standards, 6 Cum / Pole ) 61 Aluminium Jointing Sleeevs 62 Guard Netting Of 33 Kv Lines 63 Guys For 33 Kv Lines 64 Galvanised Stay Set With 50X8 Mm Stay Clamp, Guy Insulators ( 2 Nos ) , Anchor Plate ( 300X300x8mm ) , Nut Bolts, 2 Nos Turn Buckles, 1.8 M Long, 20 Mm Diameter Solid Gs Stay Rod & 7 / 4.00 Mm Dia Gi Standard Wire Complete. 65 Common Miscellaneous Works 66 Development Of Land 67 Chain Link Fencing Of 33Kv Yard Of Substation By Way Of Mass Concreting In Foundations And Chain Link Fencing Of 6Ft. Height 68 33 / 11Kv Transformer Foundation 69 33Kv Equipment Foundation ( Breakers, Cts / Pts, Isolators, Las ) 70 Earthing Mat ( Gi Flat 50Mm X 8Mm ) 71 33Kv Yard Concreting / Metalling And Laying Of Gravels 20Mm ( Complete Bays ) 72 Yard Lightening ( Complete ) With 4 No. 9 Mtr Long St Poles ( St-410 ) , Sp-33, Fitted With 2 No. 60 W Led Lights On Each Pole, Complete With Control Gear Box, Earthing And Bottoming Of Poles. 73 Rcc Cable Trench ( 1:2:4 ) For Laying Of 11 Kv Xlpe Power Cables And Control Cables From Various Equipments To Control Room & From Control Room To Outgoing Structures Alongwith Rcc Duct Covers. 74 Earthing Electrode ( 3M Long 40Mm Dia Gi Pipe ) Through Gi Strip 75 Common Miscellaneous Equipments 33 / 11Kv Substations 76 A ) . Battery Bank 30 V, 100 Ah , Of 15 No. Cells Of 2 V Each, Sealed Maintenance Free Vrla Type, High Impact Polyprophelenecopolymer Container, Flame Retardant. B ) . 30V, 100 Ah , Float-Cum-Boost Charger With Full Wave Rectification For 220 V, 1Phase, 50 Hz Ac Input Supply . 77 Distribution Panel ( 30 V, Dc ) Made Of Crca Thickness Not Less Than 2Mm. Powder Coated, Degree Of Protection Ip43 For 2 No Battery Incoming Supply With 2 No 63 Amps Dp Mcbs For Incoming Supply Doublebusbar Of Adequate Size, 12 No Dp Dc Mcb ( 0-32A ) Including Indication Lamps And Cables And Other Accessories 78 Distribution Panel ( 415 V, Ac ) Made Of Crca Thickness Not Less Than 2Mm. Powder Coated, Degree Of Protection Ip43. 200 Amps Switch Fuse Disconnector For Incoming Supply And 5 No Tpn McbS ( 16-125 Amps ) And 5 No Dp Mcbs ( 0-32A ) , Rectangular Busbar Suitable For 200 Amps Continuous Supply Including Indication Lamps And Cables And Other Accessories 79 Rubber Mat 1Mx2m 3 Mm Thick For 33 Kv 80 Fire Extingiusherco2type Of 4.5 Kg Capacity For Control Room 81 3Sand Bucket Fire Extingiusher 82 Helmet 83 Rubber Gloves For 33 Kv Level 84 Rubber Gloves For 11Kv Level 85 Safety Belt 86 Safety Shoes 87 Hv Detectors For 33 Kv 88 Earthing Rod ( Set Of 3 Rods ) 89 Rmu Along With Out Going Cable 90 33 Kv Ring Main Unit : 3 Way Out Poor Type Rmu, Sf6 Insulated, Extensible Type, At 33 Kv System Voltage And Breaking Capacity 25 Ka For One Second, With Sf6 Circuit Breaker / Vcb Self Powered With O / C+ E / F Relay System Comprsing Of A ) One Nos 33 Kv, 630 Amp. Motorized Isolators Including Earthing Switches With Making Capacity 62.5 Ka, Having Mechnical On / Offb ) Two Nos 33 Kv, 200 Amp Motorized, Spring Operated, Circuit Breakers With Earthing Switchesc ) Cu Bus-Bar Of 630 Amp. Ratingd ) One No Numerical Aux. Self Powered Relay Having Non Directional O / C And E / F Protection ( For Each Circuit Breaker Feeder ) , Relay Should Have Minimum 7-Di & 8-Do. The Relay Shall Also Interface Via An Rs 232 / 485 Port In Orde O Send, As A Minimum, Real Time Readings Using The Modbus Protocol.E ) Incoming Isolators Shall Have Fpi With Electrical Reset Contact / Facility.F ) All Necessary Potential-Free Contacts For Indications Relevent To Rmu Monitoring And Control.G ) Capacitor Voltage Dividers Serving Live-Line Cable Indicators In Each Breaker & Isolator. 91 33 Kv 3 Phase Indoor Terminating Kit To Be Used With Cables-185Mm Sq. 92 33 Kv 3 Phase Out Door Terminating Kit To Be Used With Cables-185Mm Sq. 93 Cable Route Markers 94 Excavation In Any Type Of Soil Including Hard Laterit Soil 95 Refilling Of Excavated Soil 96 Sand For Cushioning Of The Cables In The Trench 97 Cement Tiles Of Size 300 Mm Lengthx 250 Mm Widthx 37 Mm Thick As A Protective Cover For Underground Cables 98 Earthing Of Rmu- Excavation Of Earth Pit Of Dia 650 Mm & Depth 3000 Mm, Installation Of Earthing Pipe Of 40 Mm Nominal Bore & 4 Mm Wall Thickness & Length 2.5 Mtr Long As Per Is 1239. Gi Strip For Neutral Earthing Of Size 75 Mmx10mm & 50 Mm X 6 Mm For Connection Of Rmu Body As Per Is 2629 / 85, Gi Nuts And Bolts, Refilled With Earth Enhancement Materials And Earth Chamber Made Of Brick Masonary With Rcc Slab Cover. 99 Cement Concrete 1:2:4 ( 1 Cement, 2 Coarse Sand, 4 Graded Graniticor Basaltic Stoe Aggregated 40 M Nominal Size Of Foundation ) 100 Centering And Shuttering Including Struttings, Propping Etc. & Removal Of Form Work 101 15 Mm Cement Plaster 1:4 For Foundations. 102 Wire Mesh Boundary Fencing Around The Rmu 103 33 Kv, 3 Core Xlpe Cable Armoured, 185 Mm2 104 Installation Of Capacitor Bank 105 12 Kv, 1.2 Mvar, Capacitor Bank With Vcb Panel With Complete Arrangement For Conection With 11 Kv Incomer Panel , Series Reactor, Isolator, Rvt, Surge Arrestors, Ht Cable With Termination Kits, Control Cables, Crca Cubicle Panel Etc With Structure, Foundation & Accessories. 106 33 Kv Ct / Pt 107 33Kv Ct / Pt Combined Unit, With Ct Ratio 100 / 5 & Ptr 33 Kv / 110 V / V3 , 3-Phase, 50 Hz, Onan Cooled, Outdoor Type. The Combined Unit, Cts And Pts Shall Be As Per Below Specifications.The Rated Burden Of Ct Shall Be 7 Vathe Rated Burden Of Pt Shall Be 20Va Per Phase With Proper Colour Coded Identification. Pts Shall Be Of Uniform Insulating And One Minute Power Frequency Dry Withstand Voltage 70Kv 108 Metering Cubicle For 3Phase 4 Wire Metering System Suitable For 3 Phase, Ht, Tri-Vector Meter With Sealing And Locking Facility Made Of Ms Sheet Steel Thickness Not Less Than 2Mm Duly Power Coat Painted Suitable For Indoor As Well As Outdoor As Per The Site Requirement. The Cubicle Shall Be Painted Through 7-Tank Process. The External Dimensions Should Be Adequate. Provided With Synthetic Or Semi Synthetic Gasket Firmly Glued To The Surface, Dust, Weather Andvermin Proof And Shall Comply Degree Of Protection Ip 65 Both The Chambers Having One Sided Hinged Door Arrangements. The Panel Shall Be Provided With Two No Ms Channels Of Size 100 X 50 Mm On The Front And Rear Sides Duly Welded And 4 No Of Lifting Hooks. It Should Be Possible To Take Meter Reading Manually, Through Cmri And Computer Without Opening Door. Including Supply And Fixing Of 75Mm Gi Pipe Between Ct / Pt Combined Unit And Metering Cubicle For Ct / Pt Wiring To Tri-Vector Meter. 109 Gichannel & Angle For Mounting Ct Pt Combined Units With Nuts And Bolts ( Size 100 X 50 X 5 Mm ) 110 3Ph4 Wire Ht Ct / Pt Operated Fully Static Smart Tri-Vector Energy Meters Dlms Compliant Category C With Rs232 Port . 33Kv / V3 / 110V / V3, Ph-N ( 3P, 4W ) Meters For Measurement Of Different Electrical Parameters Including Active Energy ( Kwh / Mwh ) , Reactive Energy ( Kvarh / Mvarh ) , Apparent Energy ( Kvah / Mvah ) Etc. ( Make L&T, Secure Or Abb ) . 111 Pvc Copper Wire Flexible Multi-Strand Of Required Size For Secondary Connections For Ct Wiring The Minimum Wire Size Shall Be 4 Mm2 ( Ryb ) And For Pt Wiring Minimum Wire Size Shall Be 2.5 Mm2 ( Ryb ) . 112 Copper Lugs Preferably Ring Type Duly Crimped For Termination Of Wires And Tapes 113 Acsr Jumpers With Hardware Fittings Like Acsr To Ct / Pt Unit Bush Clamp, Other Hardwares As Per Site Requirement 114 Earthing 40 Mm Gi Pipe Or 20 Mm Gi Rod, 2.5 Mtr For Ct / Pt Combination Unit. Earthing Of Metering Cubicle Through Two No 25 X 5 Mm Flat Iron. 115 11 Kv Indoor Switchgear 116 11 Kv Vcb Panel Board ( 12 Kv, 1250A, 25 Ka, Outdoor ) With O / C, E / F Relays ( Iec61850 ) , Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps, Dlms Compliant With Rs-485 Port ( 1 Incomer & 3 Outgoing ) 117 11 Kv Bus Coupler Along With Adaptor Panel 118 11Kv, Gapless Surge Arrestor, 9 Kv , 10 Ka , La With Polymer Housing, Stn. Type ( 4 / 5 / 6 Sets ) 119 100 Kva, 11 / 0.433Kv, 3-Phase Distribution Transformers With Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound ) 120 11 Kv Isolater, Double Break, 3-Pole, 600 Amp, Horizental Mounting Type With Earth Switch 121 11Kv Horn Gap, 3-Phase, 3-Pole, 200 Amp 122 Pvc Armoured Cable ( Lt ) , 120Mm2 ( 3.5 Core ) 123 St Poles ( St-410 ) , Sp-33, 9 Mtrs.Long ( For 4 No. O / G Structures And 2 No. Aux Sub Station ) 124 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum Per Pole 125 Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip 126 Mccb-200 Amp With Enclosure 127 Galvanisedironoff Sorts 128 Earthing Of 100Kva Substation --Excavation Ofearth Pit Of Dia650 Mm & Depth 3000 Mm, Installation Ofearthing Pipe Of 40 Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr Long As Per Is 1239.Gi Strip For Neutral Earthing Of Size 75 Mm X10 Mm& 50 Mm X 6 Mmfor Connection Of Transformer Body, G.O Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts, Refilled With Earth Enhancement Materials And Earth Chamber Made Of Brick Masonary With Rcc Slab Cover. 129 11 Kv Xple Power Cables 130 11 Kv, 630 Mm² Single Core Xlpe Armoured, Frls. ( With One Spare Length ) 131 11 Kv, 3- Core, Xlpe 185 Mm² Armoured, Frls, 132 11 Kv Indoor Heat Shrinkabler Cable Termination Kits For 630 Mm Sq. Single Core Cable. Id / Od 133 11 Kv Outdoor Heat Shrinkabler Cable Termination Kits For 185 Mm Sq. Three Core Cable. Id / Od
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Jammu And Kashmir View Result →
10.
Public Administrative Department #10618453 Price Bid
Sub Head- Comprehensive Annual Maintenance Contract For Fire Alarm And Detection System At Charak Palika Hospital ( Old And New Building ) , Lodhi Colony Barat Ghar , Khan Market Barat Ghar And Kaka Nagar Gymnasium . , Comprehensive Amc For Fire Alarm And Detection Systems Installed At Below Cited Buildings Including Weekly / Fortnightly / Monthly Visits And Whenever Required Or In Case Of Any Defect In The System By The Team Consisting Of Engineer , Technicians And Helpers With The Aim To Keep The System Functional Round The Clock Including Servicing , Maintenance , Testing And Cleaning The System Internally As Well As Externally . The Inventory Installed In The Building For Servicing , Maintenance , Testing & Keeping The System In Perfect Order Is Available At The Respective Control Rooms Complete To The Entire Satisfaction Of Fire Officer / Engineer In Charge . Charak Palika Hospital ( Old & New Building ) A ) Engineer - 1 No . - 01 Visit / Week B ) Technical Foreman - 01 No . - 01 Visit / Week C ) Helper - 02 Nos . - 01 Visit ( Each ) / Week , Engineer , Technician , Helper , Lodhi Colony Barat Ghar , Khan Market Bagar Ghar & Kaka Nagar Gymnasium A ) Engineer - 1 No . - 01 Visit / Fortnight B ) Technical Foreman - 01 No . - 01 Visit / Week C ) Helper - 02 Nos . - 01 Visit ( Each ) / Week , Engineer , Technician , Helper , Replacement / Supply , Installaton , Testing / Commissioning Of Smoke Detector With Builtin Led And Mounting Base Complete With All Connections Etc . Complete In All Respect To The Entire Satisfaction Of Fire Officer / Engineer In-Charge , Replacement / Supply , Installaton , Testing / Commissioning Of Heat Detector Operating At 54 / 57 Degree Celsius With Rate Of Rise Cum Fixed Temperature ( Dual Thermistor ) Type With Mounting Base Complete With All Connections Etc . Complete In All Respect To The Entire Satisfaction Of Fire Officer / Engineer In-Charge , Replacement / Supply , Installaton , Testing / Commissioningof Manual Call Boxes Of Ms Construction In Surface / Recess With Stainless Steel Chain & Hammer Assembly Complete With Glass And Push Button Etc . Complete In All Respect To The Entire Satisfaction Of Fire Officer / Engineer In-Charge , Replacement / Supply , Installaton , Testing / Commissioning Of Of Fire Alarm Sounder With Facility To Make Announcement , Mounted In Ms Box ( 16Swg ) With Hinged Cover Plate & Suitable For Operation With Amplifier I / C Line Matching Transformer Etc . Complete In All Respect To The Entire Satisfaction Of Fire Officer / Engineer In-Charge , Replacement / Supply , Installaton , Testing / Commissioning Of Of Sector Panel Suitable For Following Zones , Complete With Visual Indications For Short Circuit Fault , Open Circuit Fault , Fire Condition And All Other Standard Facilities As Per Is:2189 With Mimic Diagram For All Area / Zone Covered , Complete With All Connections , Interconnections Etc . Complete In All Respect To The Entire Satisfaction Of Fire Officer / Engineer In-Charge , 4 Zone , 6 Zone , Supplying And Laying Of Of 2 X 1 . 5 Sq . Mm Fire Alarm Armoured Cable , 600 / 1000V Rated With Annealed Copper Conductor Having Xlpe Insulation , Steel Wire Armouring & Frls Outer Sheath Complete In All Respect To The Entire Satisfaction Of Fire Officer / Engr-In-Charge . , Credit Of Unserviceable Materials Including Dismantling The Same And Removal From The Site / Disposing Off As Per Norms And Specifications Complete All As Specified And As Directed By Fire Officer / Engr-In-Charge . , Smoke / Heat Detectors Obtained From Item No . 02 & 03 , Manual Call Boxes Obtained From Item No . 04 , Fire Alarm Sounder Obtained From Item No . 05 , Fire Alarm Panels Obtained From Item No . 06
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
11.
Public Administrative Department #10618443 Price Bid
Annual Repair And Maintenance Of Fire Alarm , Detection And Pa Cum Talk Back System At Various Ndmc Buildings During 2020-21 . Sub Head- Comprehensive Amc For Fire Alarm And Detection System At Lok Nayak Bhawan And Palika Bhawan , Comprehensive Amc For Fire Alarm And Detection Systems Installed At Below Cited Buildings Including Weekly / Fortnightly / Monthly Visits And Whenever Required Or In Case Of Any Defect In The System By The Team Consisting Of Engineer , Technicians And Helpers With The Aim To Keep The System Functional Round The Clock Including Servicing , Maintenance , Testing And Cleaning The System Internally As Well As Externally . The Inventory Installed In The Building For Servicing , Maintenance , Testing & Keeping The System In Perfect Order Is Available At The Respective Control Rooms Complete To The Entire Satisfaction Of Fire Officer / Engineer In Charge . Lok Nayak Bhawan And Palika Bhawan A ) Engineer - 1 No . - 01 Visit / Fortnight B ) Technical Foreman - 01 No . - 01 Visit / Week C ) Helper - 02 Nos . - 01 Visit ( Each ) / Week , Engineer , Technician , Helper , Replacement / Supply , Installaton , Testing / Commissioning Of Smoke Detector With Builtin Led And Mounting Base Complete With All Connections Etc . Complete In All Respect To The Entire Satisfaction Of Fire Officer / Engineer In-Charge , Replacement / Supply , Installaton , Testing / Commissioningof Manual Call Boxes Of Ms Construction In Surface / Recess With Stainless Steel Chain & Hammer Assembly Complete With Glass And Push Button Etc . Complete In All Respect To The Entire Satisfaction Of Fire Officer / Engineer In-Charge , Replacement / Supply , Installaton , Testing / Commissioning Of Fire Alarm Sounder With Facility To Make Announcement , Mounted In Ms Box ( 16Swg ) With Hinged Cover Plate & Suitable For Operation With Amplifier I / C Line Matching Transformer Etc . Complete In All Respect To The Entire Satisfaction Of Fire Officer / Engineer In-Charge , Replacement / Supply , Installaton , Testing / Commissioning Of Of Sector Panel Suitable For Following Zones , Complete With Visual Indications For Short Circuit Fault , Open Circuit Fault , Fire Condition And All Other Standard Facilities As Per Is:2189 With Mimic Diagram For All Area / Zone Covered , Complete With All Connections , Interconnections Etc . Complete In All Respect To The Entire Satisfaction Of Fire Officer / Engineer In-Charge , 4 Zone , 6 Zone , Supplying And Laying Of 2 X 1 . 5 Sq . Mm Fire Alarm Armoured Cable , 600 / 1000V Rated With Annealed Copper Conductor Having Xlpe Insulation , Steel Wire Armouring & Frls Outer Sheath Complete In All Respect To The Entire Satisfaction Of Fire Officer / Engr-In-Charge . , Credit Of Unserviceable Materials Including Dismantling The Same And Removal From The Site / Disposing Off As Per Norms And Specifications Complete All As Specified And As Directed By Fire Officer / Engr-In-Charge . , Smoke Detectors Obtained From Item No . 02 , Ms Manual Call Boxes Obtained From Item No . 03 , Fire Alarm Sounder Obtained From Item No . 04 , Fire Alarm Panels Obtained From Item No . 05
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
12.
Housing Urban and Rular Development #10598804 Price Bid
Upgradation Of Existing Fire Fighting Down Comer System And supply installation testing and commissioning Of Manual Operated Fire Alarm System At In Licensing Unit Building At Police Station Defence Colony , New Delhi , Sub Head-I- Upgradation Of Downcomer SystemSupplying , Installation , Testing And Commissioning Of Electric Driven Terrace Pump Suitable For Automatic Operation And Consisting Of Following , Complete In All Respects , As Required: ( Terrace Pump ) ( A ) Horizontal Type , Multistage , Centrifugal , Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft , Mechanical Confirming To Is : 1520 . ( B ) Suitable Hp Squirrel Cage Induction Motor Tefc Type Suitable For Operation On 415 Volts , 3 Phase , 50 Hz , Ac Supply With Ip55 Class Of Protection For Enclosure , Horizontal Foot Mounted Type With Class-F Insulation , Conforming To Is-325 . ( C ) M . S . Fabricated Common Base Plate , Coupling , Coupling Guard , Foundation Bolts Etc . As Required . ( D ) Suitable Cement Concrete Foundation Duly Plastered And With Anti Vibration Pads . ( E ) 450 Lpm At 35 M Head . , Providing & Fixing Of Pressure Switch In M . S . Pipe Line Including Connection Etc . As Required . , Providing Laying , Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 1239/3589 I/C Fittings Like Elbows , Tees , Flanges , Tapers , Nuts Bolts , Gaskets Etc . In Ground Including Welding , Excavation & Providing Cement Concrete Blocks As Supports , Anticorrosive Treatment With Coaltar/Asphalt Tape As Per Is 10221 , Refilling The Trench Etc . Of Following Sizes Complete As Required . , 100 Mm Dia . , Providing , Laying , Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 3589/Is 1239 Including Welding , Fittings Like Elbows , Tees , Flanges , Tapers , Nuts Bolts , Gaskets Etc . And Fixing The Pipe On The Wall/Ceiling With Suitable Clamp/Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required : , 100 Mm Dia , 25 Mm Dia , Supplying , Fixing , Testing And Commissioning Of Butterfly Valve Of Pn 1 . 6 Rating With Bronze/Gunmetal Seat Duly Isi Marked Complete With Nuts , Bolts , Washers , Gaskets Conforming To Is 13095 Of Following Sizes As Required : , 100 Mm Dia , Providing , Installation , Testing And Commissioning Of Non-Return Valve Of Following Sizes Confirming To Is: 5312 Complete With Rubber Gasket , Gi Bolts , Nuts , Washers Etc . As Required : , 100 Mm Dia , Supplying , Fixing , Testing & Commissioning Of Double Flanged Sluice Valve Of Rating Pn 1 . 6 With Non Rising Spindle , Bronze/Gun Metal Seat , Isi Marked Complete With Nuts , Bolts , Washers , Gaskets And Conforming To Is 780 Of Following Sizes As Required . , 100 Mm Dia , Providing & Fixing Of Pressure Switch In M . S . Pipe Line Including Connection Etc . As Required , Supplying And Fixing First-Aid Hose Reel With Ms Construction Spray Painted In Post Office Red , Conforming To Is 884 Complete With The Following As Required . 20 Mm Nominal Internal Dia Water Hose Thermoplastic ( Textile Reinforced ) Type -2 As Per Is: 12585 20 Mm Nominal Internal Dia Gun Metal Globe Valve & Nozzle . Drum And Brackets For Fixing The Equipmets On Wall . Connections From Riser With 25 Mm Dia Stop Gun Metal Valve & M . S . Pipe And Socket . , 30 Mtr . , Supplying And Fixing Of Fire Brigade Connection Of Cast Iron Body With Gun Metal Male Instantaneous Inlet Couplings Complete With Cap And Chain As Reqd . For Suitable Dia Ms Pipe Connection Conforming To Is 904 As Required : , 2 Way-100 Mm Dia M . S . Pipe , Supplying And Fixing 63 Mm Dia , 15 M Long Rrl Hose Pipe With 63 Mm Dia Male And Female Couplings Duly Bound With Gi Wire , Rivets Etc . Conforming To Is 636 ( Type-A ) As Required : , Stainless Steel ( Grade 304 ) , Supplying And Fixing Single Headed Internal Hydrant Valve With Instantaneous Stainless Steel Coupling Of 63 Mm Dia With Cast Iron Wheel Isi Marked Conforming To Is 5290 ( Type -A ) With Blankgunmetal/Stainless Steel Cap And Chain As Required : , Single Headed Stainless Steel , Fabrication Supply Installation Testing And Commissioning Of Hose Cabinet Of Size 750 Mmx600mmx250mm Made Of 1 . 6Mm Thick ( Double Door ) Ms Sheet With 6 Mm Thick Glass Doors Including Necessary Locking Arrangements ( 30 X 24 X 10 ) Suitable For 2 Nos . 15 Mtr . Hose And 1 No . Short Branch Pipe . Complete Etc . As Required . , Supplying & Fixing 63 Mm Dia Short Branch Pipe With 20 Mm Nominal Internal Diameter Size Nozzle Conforming To Is 903 Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required : , Stainless Steel ( Grade 304 ) , Supplying And Fixing Air Vessel Made Of 250 Mm Dia , 8 Mm Thick Ms Sheet , 1200 Mm In Height With Air Release Valve On Top And Flanged Connection To Riser , Drain Arrangement With 25 Mm Dia Gun Metal Wheel Valve With Required Accessories , Pressure Gauge And Painting With Synthetic Enamel Paint Of Approved Shade As Required . , Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank , Is : 12701 Marked , With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet , Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank . , Circular Tank , Painting ( One Or More Coats ) On Rain Water , Soil , Waste And Vent Pipes And Fittings With Synthetic Enamel Paint Of Approved Brand And Manufacture And Required Colour On Old Work . , One Or More Coats On Old Work , Credit For Following Dismantle Items . , 100Mm Butterfly Valves , Hose Reel Drum , 2 Way Fire Brigade Connection , Double Door Hose Cabinet , Terrace Pump , Scrap Polyethylene 2000 Ltrs . Circular Water Tank . , Sub Head-Ii- Sitc Of Manual Fire Alarm SystemSupplying , Installation , Testing & Commissioning Of Main Control And Indicating Panel Made Out Of 16 Swg Ms Sheet To Accommodate The Following Items Duly Powder Coated In Approved Colour With Louvers For Ventilation , Locking Arrangement , Audio And Visual Indication For Fire Alarm And Public Address System , Monitoring System Including Connections , Interconnections Etc Complete As Required . 10 Zone Panel For Fire Alarm System 250 Watt Amplifier Racks Suitable For Operation On 230V Ac/24V Dc Supply Conforming To Iec-268-3 Complete With All Accessories As Required - 2 Nos . ( One To Act As Standby ) Talk Back Master Station With Led Ptt ( Press To Talk ) Push Button For Operation On 230V Ac/24 V Dc Supply Conforming To Iec-268 For Simplex Mode Of Operation/Communication Suitable For 20 Nos . Talk Back Unit -1 Set . Announcement Control Desk Suitable For Selection Of Different Zones Selectively And On All Call Switch With Visual Indication Etc . Complete As Required -1 Set . Amplifier Change Over Switch For Inter Changing Amplifier -1 No . Monitor Panel For Loudspeaker Complete With Output Selector , , On/Off Switch , Fuse , Visual Indications Etc . Complete As Required- 1 No . Gooseneck Microphone With Stand And On/Off Switch- 1 No . Main On/Off Switch , Fuse Indication Lamps , Dc And Ac Voltmeters & Ammeters , Terminal Blocks Etc . Complete As Required -1 Set . Battery Charger Trickle Cum Boost To Take Complete Load Of Fire Alarm & Pa System Complete With All Accessories Including Providing & Fixing Of 2 Nos . 12 Volt , 60 Ah Each Sealed Maintenance Free Batteries -1 Set . , Supplying , Installation , Testing & Commissioning Sector Panel Suitable For Following Zones , Complete With Visual Indications For Short Circuit Fault , Open Circuit Fault , Fire Condition And All Other Standard Facilities As Per Is:2189 With Mimic Diagram For All Area/Zone Covered , Complete With All Connections , Interconnections As Required . , 4 Zone , Supplying , Installation , Testing & Commissioning Of Smoke Detector With Built In Led And Mounting Base Complete With All Connect
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
13.
Housing Urban and Rular Development #10579536 Price Bid
Annual Repair And Maintenance Of Various Electrical Installation And Mechanical Equipments At Combined Food And Drugs Lab, Lawrence Road, Delhi. ( Sh Repairing Of Existing Agni Make Fire Alarm System ) .- Supplying, Installation, Testing & Commissioning Of Heat Detector Operating At 54ºc / 57ºc With Rate Of Rise Cum Fixed Temperature ( Dual Thermistor ) Type With Mounting Base Complete With All Connection Etc. As Required. 2 Supplying, Installation, Testing & Commissioning Of Smoke Detector With Builtin Led And Mounting Base Complete With All Connections Etc. As Required. 3 Supplying, Installation, Testing & Commissioning Of Manual Call Box Of Abs Type In Surface / Recess With Stainless Steel Chain & Hammer Assembly Complete With Glass And Push Button Etc. As Required. 4 Supplying, Installation, Testing & Commissioning Response Indicator On Surface / Recess Ms Box Having Two Leds Metallic Cover Complete With All Connections Etc. As Required. 5 Supplying, Installation, Testing & Commissioning Fire Alarm Sounder With Facility To Make Announcement, Mounted In A.B.S. Box With Hinged Cover Plate & Suitable For Operation With Amplifier I / C Line Matching Transformer Etc. Complete As Required. 6 Supplying, Installation, Testing & Commissioning Sector Panel Suitable For Following Zones, Complete With Visual Indications For Short Circuit Fault, Open Circuit Fault, Fire Condition And All Other Standard Facilities As Per Is:2189 With Mimic Diagram For All Area / Zone Covered, Complete With All Connections, Interconnections As Required.A ) 6 Zone Panel 7 Supplying & Laying Of 2 X 1.5 Sqmm Fire Alarm Armoured Cable, 600 / 1000 V Rated With Annealed Copper Conductor Having Xlpe Insulation , Steel Wire Armouring & Frls Outer Sheath Complete As Required. 8 Rectificationoffaultsof Amplifier Pa System With Main Firealarmpanel 16 Zone Bylocatingthetypeoffaultsfrom Ground Floor To Thirdfloors Ofbuildinginallroomswhereverrequiredincludingfaulty Detectors, Faulty Cable Lines And Associated Accessories Complete Wherever Required Below & Above False Ceiling And Setting Right All The Faults By Necessary Repairing / Replacement Of Parts & Tapping / Tightening Of Connection Cables Etc. Complete As Required 9 S / I / T / C Of Led Lit Signage Board Bi-Langual Super Bright Red / Green LedS With Sign Like Hydrant , Lift Etc Made Of Ms Housing Powder Coated Having Acrylic Sheet Etched With Super Bright Led Less Then 2 Watt Having Ni-Mh / Nicd Battery With Back Up Of 10 Hours Of Standard Size Of 350Mmx170 Mm Recharge Period Of 12 Hours Operating Voltage Of -190 To 230V Etc Complete Required.A ) Single Sided 10 B ) Double Sided 11 Credit For Following Old / Dismantle Material Received From Above Work I / C Dismantling & Removal From Site .A ) Assorted Cable 12 B ) Assorted Faulty Detectors 13 C ) Faulty / Damaged Sector Panels 14 D ) Assorted Manual Call Boxes / Sounder / Signage Boards
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
14.
Power #10541354 Price Bid
Installation Of Various Substation Equipment And Allied Works At Proposed South City Retreat Substation Under Bhangar Division Installation Of Various Sub-Station Equipment And Allied Works I . R . O . Proposed South City Retreat 33/11 Kv Sub/Station At Korolberia Under Bhangar Division , Wbsedcl , Erection , Testing And Commissioning Of Rtcc Panel For 10 . 0 Mva Ptr Within The Control Room By Fixing Of Panel By Providing Foundation Bolts , Earthing Etc . Considering Original Equipment Manufacturer Recomendation , Technical Specification , & Scope Of Work . , Erection , Testing And Commissioning Of 33 Kv Bus ( Acsr 200 Sqmm Conductor ) And Droppers Including Jumpers Through Various Equipment Using 11 Kv And 33 Kv Insulators , Gi Pin , Gi Hardware Fittings , T-Connectors , Insulators Etc As Required As Per Approved Drawings , Specifications And Scope Of The Work . , Erection , Testing And Commissioning Of 33Kv , 400A , 28 . 8Ka For 3 Sec , 3-Ph Double Break Center Rotating Type ( Dbcr ) Isolator Along With Support Insulators , Operating Mechanism , Base Channel Down Pipe And All Required Accessories Complete As Per Approved Drawings , Technical Specifications And Scope Of The Work , , Erection , Testing And Commissioning Of 42Kv , 10 Ka , 1-Ph Station Class Lightening Arresters On Fabricated Structure Etc As Required , As Per Approved Drawings , Technical Specifications And Scope Of The Work . ( 1 Set =3 Nos ) , Erection , Testing And Commissioning Of 36 Kv , 1-Phase , 33Kv/110 Volt , Single Core Outdoor Type Potential Transformer Along With Junction Box ( 1 No Junction Box For 3 No Of 1-Phase Pts ) Including Laying Of Control And Power Supply Cabling And Required Accessories Upto Junction Box On Fabricated Structure Etc . , Complete As Per Approved Drawings , Technical Specifications And Scope Of The Work . ( 1 Set =3 Nos ) , Erection , Testing & Commissioning Of 36Kv , 1250A , 25Ka For 3 Seconds , 3-Ph , Outdoor Type Vacuum Circuit Breaker With Supporting Structures , Bi-Metallic Clamps Suitable For 200 Sqmm Acsr Conductor , Permanent Maintenance Platform , Marshalling Box Etc Required As Per Technical Specifications , Approved Drawings And Scope Of Works . , Erection , Testing & Commissioning Of 33Kv Ct ( 1-Phase ) , Outdoor Type Dual Core Ct Ratio 400-200 / 1-1A With Supporting Structures , Bi-Metallic Clamps Suitable For 200 Sqmm Acsr Conductor , Permanent Maintenance Platform , Marshalling Box Etc Required As Per Technical Specifications , Approved Drawings And Scope Of Works . , Design , Engineering Providing And Installation Of Ismc 100 Channel On Top Of Indoor Trench , Erection Of Panels On Ismc 100 Channels , Welding , Testing And Commissioning Of 33Kv Indoor Control & Relay Panel Along With E/F & O/C Relays , Control And Power Supply Cabling In Trench Between Field Equipment And Panels , Mimic Diagram , Voltmeter , Ammeter , Annunciation Windows With Annunciation Relays And Other Components Etc As Per Approved Drawings , Technical Specifications And Scope Of The Work For Controlling . , Installation , Initial Charging , Cabling , Interconnection , Testing And Commissioning Of 30V , 100 Ah Pb Acid Battery On Battery Stand Made Of Teak Wood Duly Painted With Anti Rusting Paint , Battery Insulators , Inter-Battery Wiring , Terminal Connectors , & All Other Accessories And Connectors Including Design , Engineering , Construction & Commissioning Of 30V , 35 Amp . Float-Cum-Boost Battery Charger With Full Wave Rectification For 230 V , 1 Phase , 50 Hz Ac Input Supply As Per Approved Drawings , Technical Specifications And Scope Of The Work , , Supply & Erection Of High Mast Type Lightning Cum Lightning Mast With Foundation & Fitting & Supply & Installation Of Surge Arrester , Laying , Testing And Commissioning Of 1 . 1Kv Control Cables In Cable Trench /Pipes/ Underground / Overhead Laying Including Their Termination At Indoor/Outdoor Terminals Including Supply Of Glands , Lugs , Cable Ties , Tagging Etc As Required As Per Technical Specification , Approved Drawing & Scope Of Works . A ) 4 Core 2 . 5 Sqmm Armored , Stranded Copper Conductor , Pvc Insulated And Pvc Sheathed Cable , B ) 8 Core 2 . 5 Sqmm Armored , Stranded Copper Conductor , Pvc Insulated And Pvc Sheathed Cable , C ) 12 Core 2 . 5 Sqmm Armored , Stranded Copper Conductor , Pvc Insulated And Pvc Sheathed Cable , Erection Of Gantry Structure With Provision For Isolator & La With Foundation Alongwith Supply Of Nuts & Bolts And La Base Plate 430X430x8 Mm , Erection Of Isolator Cum La Support Structure With Foundation Along With Supply Of All Nuts & Bolts And La With Foundation Base Plate 430X430x8 Mm , Erection Of H/L Bus Support Structure With Foundation & Supply Of All Nuts & Bolts , Erection Of L/L Bus Support Structure With Foundation & Supply Of All Nuts & Bolts , Supply Of Galavanised Fabricated Steel Items For Gantry Structure ( Sl No-14 ) , Isolator Cum La Support Structure For Ptr ( Sl No-15 ) , H/L Bus Support Structure ( Sl No-16 ) , L/L Bus Support Structure ( Sl No-17 ) By Providing Red Oxide Painting And Aluminium Painting Etc As Required As Per Technical Specification Is:4759 ( Zinc Coating Shall Not Be Less Than 610Gm/Sq . Meter ) All Structural Steel Shall Conform To Is 2062 . All Weld Shall Be 6Mm Fillet Weld Unless Specified Otherwise . All Nuts And Bolts Shall Be Of Property Class 5 . 6 Of Is 1367 . Plain Washers Shall Be As Per Is 2016 & Spring Washers Shall Be Is: 3063 As Per Technical Specifications , Scope Of Works And Approved Drawings . , Supply & Erection Of Galavanised Fabricated Steel Items On 9Mtr Pcc 14 Pole Structure For 11Kv O/G Feeders & Supply & Erection Of Lattice Structure ( Galvanised ) For Ct & Pt Only Using Nuts & Bolts , By Providing Red Oxide Painting And Aluminium Painting Etc As Required As Per Technical Specification , Approved Drawing & Scope Of Works All Structural Steel Members And Nut Bolts Shall Be Galvanized After Fabrication As Per Is:4759 ( Zinc Coating Shall Not Be Less Than 610Gm/Sq . Meter ) For All Structural Steel Members . All Structural Steel Shall Conform To Is 2062 . All Weld Shall Be 6Mm Fillet Weld Unless Specified Otherwise . All Nuts And Bolts Shall Be Of Property Class 5 . 6 Of Is 1367 . Plain Washers Shall Be As Per Is 2016 & Spring Washers Shall Be Is: 3063 As Per Technical Specifications , Scope Of Works And Approved Drawings . , Erection , Testing And Commissioning Of 33 Kv Polymer Pin Insulator With Gi Pin ( Composite ) Including Their Hardware Fittings As Per Technical Specification , Approved Drawings And Scope Of Work . , Erection , Testing And Commissioning Of 33 Kv Polymer Disc Insulator With Strain Hardware ( Composite ) Including Their Hardware Fittings As Per Technical Specification , Approved Drawings And Scope Of Work . , Erection , Testing And Commissioning Of 33 Kv Post Insulator Porcelain Including Their Hardware Fittings As Per Technical Specification , Approved Drawings And Scope Of Work . , Installation Of 100 Kva Station Transformer , Supply Of 33 Kv Connectors Ct Connector To Panther ( Gun Metal ) , Pt Connector To Panther ( Extuded Al ) , Supply Of Isolator Pad To Panther Acsr 200Sqmm Bus ( Extruded Al ) , Supply Of Bus Joint ( Panther ) Bus To Bus T-Connector ( Extruded Al ) , Panther Support Clamp At 11 Kv Cable End Support On Post Insulator , 10 . 0 Mva Ptr To Panther Connector ( Gun Metal ) , Vcb Pad To Panther ( Extruded Al ) , Panther To Panther/Dog T Connector ( Extruded Al ) , La To Panther/Dog ( Extruded Al )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
West Bengal View Result →
15.
Public Administrative Department #10529850 Price Bid
Comprehensive annual maintenance contract for Fire Alarm and Detection System at various at Palika Parking, Mohan Singh Place, Shaheed Bhagat Singh Place and Palika Place in NDMC area . , comprehensive amc for fire alarm and detection systems installed at below cited buildings including weekly/fortnightly/monthly visits and whenever required or in case of any defect in the system by the team consisting of engineer , technicians and helpers with the aim to keep the system functional round the clock including servicing , maintenance , testing and cleaning the system internally as well as externally . the inventory installed in the building for servicing , maintenance , testing & keeping the system in perfect order is available at the respective control rooms complete to the entire satisfaction of fire officer/engineer in charge . i ) palika parking ii ) mohan singh place iii ) shaheed bhagat singh place iv ) palika place a ) engineer - 1 no . - 01 visit / week b ) technical foreman - 01 no . - 01 visit / week c ) helper - 02 nos . - 01 visit ( each ) / week note : atleast 01 visit/week/building is required by the team consisting of 01 engineer , 01 technician and 02 helpers , engineer , technician , helper , replacement/supply , installaton , testing/ commissioning of smoke detector with builtin led and mounting base complete with all connections etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , replacement/supply , installaton , testing/ commissioning of heat detector operating at 54/57 degree celsius with rate of rise cum fixed temperature ( dual thermistor ) type with mounting base complete with all connections etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , replacement/supply , installaton , testing/ commissioningof manual call boxes of ms construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , replacement/supply , installaton , testing/ commissioning of response indicator on surface / recess ms box having two leds metallic cover complete with all connections etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , replacement/supply , installaton , testing/ commissioning of fire alarm sounder with facility to make announcement , mounted in ms box ( 16swg ) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , replacement/supply , installaton , testing/ commissioning of of fire alarm sounder with facility to make announcement , mounted in abs box ( 16swg ) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , replacement/supply , installaton , testing/ commissioning of of sector panel suitable for following zones , complete with visual indications for short circuit fault , open circuit fault , fire condition and all other standard facilities as per is:2189 with mimic diagram for all area/zone covered , complete with all connections , interconnections etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , 4 zone , 6 zone , supplying and laying of 2 x 1 . 5 sq . mm fire alarm armoured cable , 600/1000v rated with annealed copper conductor having xlpe insulation , steel wire armouring & frls outer sheath complete in all respect to the entire satisfaction of fire officer / engr-in-charge . , credit of unserviceable materials including dismantling the same and removal from the site/ disposing off as per norms and specifications complete all as specified and as directed by fire officer/engr-in-charge . , smoke/heat detectors obtained from item no . 02 & 03 , ms manual call boxes obtained from item no . 04 , response indicators obtained from item no . 05 , fire alarm sounder obtained from item no . 06 & 07 , fire alarm panels obtained from item no . 08
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
17.
Educational and Research Institute #10354560 Price Bid
Tender For Supply installation Of Additional Safety Items For Krishi Radio Station At Main Campus Shalimar, Skuast-K.(Capex)- 1 FIRE DETECTION & ALARM SYSTEM 2 Supplying, installation, testing & commissioning sector controlpanel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 3 4 zone 4 Supplying, installation, testing & commissioning of heat detector Each operating at 54°C/57°C with rate of rise cum fixed tempreature (dual thermistor) type with mounting base complete with all connection etc. as required. 5 Supplying, installation, testing & commissioning of smoke detector Each with builtin LED and mounting base complete with all connections etc. as required. 6 Supplying, installation, testing & commissioning of manual call Each boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as recuired 7 Supplying, installation, testing & commissioning response indicator Each on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. 8 Supplying, installation, testing & commissioning fire alarm sounder Each with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 9 Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. 10 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 11 Supplying and fixing of CO2 type fire extinguisher ISI marked confirming to IS: 15683 capacity 4.5 Kg complete with delivery hose horn, squeeze grip release valve , locking arrangement, operation manual, bracket with two screw and sleeve including transportation cartageupto various post in Kashmir region of SIB as per Anexure attached etc complete as required.(Make : Life Guard/Minimax/Safeguard) 12 Providing and fixing ABC type (Dry Power Type ) Extinguisher as per IS: 15683 consisting of welded MS cylindrical body, with discharge hose, dischargevalve, suspension bracket, initial filling,pressure gauge including transportation cartageupto various post in Kashmir region of SIB as per Anexureattached.etc complete as required. (Make : Life Guard/Minimax/Safeguard) 13 Capacity 6 Kg. 14 Fabrication, supply, installation, testing & commissioning of Indoortype compartmentalized feeder pillar having front area not less than 0.60 Sqmtr (900 mm x 900 mm) and depth 45 Cm (NS)made out of 2mm thick CRCA sheet with tappered roof having separate cable and bus bar alley, 1 door arrangement i/c locking arrangement, having 400 Amp four polealuminium bus bar of full length with base frame made out of50mmx50mmx6mm (thick)angle iron having 80cm legs for erection in ground with construction of cement concretesuitable foundationsizecomplete with connections and interconnections with copper conductor PVC insulated cables/ insulated aluminium busbar strips of appropriate size and terminal blocks (on outgoing) including supplying & fixing following switchgears & accessories there in, powder coating, labelling, earthing etc. complete as required. Providing and fixing following accessories in existing cubical panel board i/c making connection etc. as reqd. Details as under Panel Powder Coated 2.0mm MCCB160 A 4P 50kA , Thermalrelease 50KA1 No. MCCB TPN 63 A -1 No Indication set Spreader Terminals For DU MCCB 1 Set , , Panel Accessories like nut bolts, locks, etc Outgoing 125 MCCB FP= 1 No with Under voltage and over voltage relay and contactor included Shunt trip coil . 15 Supply , laying of 1100 V core3.5 C 70 AXYY XLPE 1100VXLPE armored cablein 4 B Type/ HDPEHeavy duty pipe etc 16 Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. 17 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 18 Note:-The rates quoted are inclusive of all carriages of materials (Mechanical/Manual) from source to site workand all extra charges including dewatering if any during the execution of work till complete in all respects.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Jammu And Kashmir View Result →
18.
Health and Family Welfare #10350409 Price Bid
Tender For supply of Digital Pet Ct Scanner As Per The Specification Except The Following , Advanced Dedicated Work Station For Pet-Ct With Oncology, Cardiology & Neurology Packages , Dual Head Injector , Dry Laser Imager , Full System Ups , Lead Glass , Additional Workstation With 1 Tb Storage Capacity , Dose Calibrator For Pet , Portable Survey Meter For Pet , Contamination Monitor For Pet , Personal Pocket Dosimeter , Tungsten Vial Shield For Carrying Isotopes , Syringe Shields For 2 & 5 Ml , Shielded Waste Decay Drum For Pet Radionuclide , L Bench With Lead Glass For Pet , Lead Lined Storage Cabinet , Interlocking Lead Bricks Including Corner Blocks , Shield Lead Carrier For Pet Doses , Light Weight Vinyl Lead Apron Of 0.5Mm Lead Equivalent , Foot Operayive Waste Bin For Pet , Dose Calibrator Shileding Ring For Pet , Dose Dispensing Unit , Decontamination Kit , Tongs 12, 18 And 24 Inch , Transport Container (Biodex Or Equivalent) , Cushioned Sofa Seats , Icu Trolley , Water Purifier (Hot And Cold) , Televisions 42 , Office Table , Dining Table With 10 Chair , Rubco Chairs , Modular Book Shelf With Glass Doors , Library Chair , Library Table , Jefferson Chair , Projector And Screen , Sound System With Fixed Mic And Wireless Mic , Pharma Refrigerator 400L , Induction Cooker , Non Revolving Chair , Refrigerator 260L , Emergency Trolley , External Lasers , 15.3 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.12.1 Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead: Of Area Beyond 3 Sq. Metre , 15.23.1Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , 15.57 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , 15.60 Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , 2.31Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 50.2.25.1 Filling With Contractors Own Earth ( Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.4.1.1 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size) Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing For Leveling Coarse Of Floor And Roof Etc. , 5.2.2Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , 50.5.33.1Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M- 20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note: Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Up To Plinth Level , 50.5.5Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults, Shells, Folded Plate And Roof Having Slope More Than 15 Degree Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand: 3 Graded Stone Aggregate 20 Mm Nominal Size). , 50.5.33.2 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-20 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note:- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess Or Less Cement Used As Per Design Mix Is Payable Or Recoverable Separately. All Work Above Plinth Level Upto Floor V Level , 5.22.1 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelmild Steel And Medium Tensile Steel Bars , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.1Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Foundations, Footings, Bases Of Columns, Etc For Mass Concrete , 5.9.2Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers , 2.34.1Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified.Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , 2.35.1.1Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion):Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos /Lindane E.C. 20% With 1% Concentration , 24.2Providing And Fixing Double Scaffolding System (Cup Lock Type ) On The Exterior Side Of Building/Structure, Upto 25 Metre Height, Above Ground Level, Including Additional Rows Of Scaffolding In Stepped Manner As Per Requirement Of Site, Made With 40 Mm Dia M.S. Tube, Placed 1.5 Metre Centre To Centre, Horizontal & Vertical Tubes Joint With Cup & Lock System With M.S. Tubes, M.S. Tube Chakkus, M.S. Clamps And Staircase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For Execution Of Work Of Cleaning And / Or Pointing And / Or Applying Chemical And Removing It Thereafter. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connecting With The Building Etc, Wherever Required, If Feasible, For Inspection Of Work At Required Locations With Essential Safety Features For The Workmen Etc., Complete As Per Directions And Approval Of Engineer-In-Charge. Note: - ( 1) The Evaluational Area Of The Scaffolding Shall Be Measured For Payment Purpose, (2) The Payment Will Be Made Once Only For Execution Of All Items Of Such Works. , 6.26.2Brick Work With Common Burnt Clay Selected F.P.S (Non Modular ) Bricks Of Class Designation 7.5 In Exposed Brick Work Including Making Horizontal And Vertical Grooves 10 Mm Wide 12 Mm Deep Complete In Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand)Above Plinth Level And Upto Floor V Level , 50.6.1.2Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 50.6.3.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete , Providing And Fixing Gi Chicken Wire Mesh 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes Including Cement Slurry And Pegs/Nails With Nailing Machine As Required Before Plastering Etc. Complete , 13.1.1Cement Plaster12 Mmof Mix: 1:4 ( 1 Cement : 4 Fine Sand) , 13.7.1Cement Plaster 12 Mmfinished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand) , 13.12- 18 Mm Cement Plaster In Two Coats Under Layer 12 Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand )And A Top Layer 6 Mm Thick Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand) Finished Rough With Sponge. , 22.5Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B) Second Layer Of Slurry Of Cement @ 0.242 Kg /Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , 11.37Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , 11.41.3 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 800X 800 Mm , Od31976/2023_2024Providing And Fixing First Quality Vitrified Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.48.2 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge. Size Of Tile 600X600 Mm , 11.48.3Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade (0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg). Including Filling /Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 800X800mm , 11.55.1 Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , 50.9.1.1Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood , 50.9.2.1Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge. Using Anjili/ Jack Wood , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , Od31977/2023_2024 Supplying And Fixing Flush Door Shutter, Shutter Of Required Size, Thickness 30Mm Thick, Finished With 1 Mm Laminate Of Approved Shade With 9 X 16 Clear Glass Vision Panels As Per Design Including Necessary Hinges , Od31978/2023_2024 Frosted Film - Supply And Installation Of 3M Make Frosted Film Pattern Throughout All The Internal Glass Panels Wherever Required Of Approx. 1.5 M Height As Per The Approved Pattern. , Od31979/2023_2024 Providing And Fixing Extruded Section Body Tubular Type Universal Hydraulic Door Closer(Having Brand Logo With Is: 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete , Od31980/2023_2024 Providing And Fixing 4.00 Mm Thick Acp Sheet For Cupboard Including All Cost, Conveyance, Labour Charges Etc Complete , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , 12.45.2 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/ Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With: 12.5 Mm Thick Tapered Edge Gypsum Fire Resistant Board Conforming To Is; 2095-Part I , 12.54.1 Providing And Fixing Gi Clip In Metal Ceiling System Of 600X600 Mm Module Which Includes Providing And Fixing C Wall Angle Of Size 20X30x20 Mm Made Of 0.5 Mm Thick Pre Painted Steel Along The Perimeter Of The Room With Help Of Nylon Sleeves And Wooden Screws At 300 Mm Center To Centre, Suspending The Main C Carrier Of Size 10X38x10 Mm Made Of G.I Steel 0.7 Mm Thick From The Soffit With Help Of Soffit Cleat 37X27x25x1.6 Mm, Rawl Plugs Of Sixe38x12 Mm And C Carrier Suspension Clip And Main Carrier Bracket At 1000 Mm C/C. Inverted Triangle Shaped Spring Tee Having Height Of 24 Mm And Width Of 34 Mm Made Of Gi Steel 0.45 Mm Thick Is Then Fixed To The Main C Carrier And In Direction Perpendicular To It At 600 Mm Centers With Help Of Suspension Brackets. Wherever The Main C Carrier And Spring T Have To Join, C Carrier And Spring T Connectors Have To Be Used. All Sections To Be Galvanized @ 120 Gms/Sqm (Both Side Inclusive), Fixing With Clip In Tiles Into Spring T With :Gi Metal Ceiling Clip In Plain Beveled Edge Global White Color Tiles Of Size 600X600 And 0.5Mm Thick With 25 Mm Height, ,Made Of G.I Sheet Having Galvanizing Of 100 Gms/ Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending . , 12.58.1 Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Interlocking Metal Grid Of Hot Dipped Galvanized Steel Sections (Galvanized @ 120 Grams/ Sqm, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Space Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening Of Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanized Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. 8Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Process To Give Stable Crystalline Structure With Minimum Compressive Strength 225 Kg/ Sq. Cm, Bending Strength 100 Kg/Sq. Cm, Of Size 595X595 Mm, Having Perforation Of Dia, 10 Mm With Minimum Perforated Area 18% With Non Woven Tissue On The Back Side, Having An Nrc (Noise Reduction Coefficient) Of 0.85, With 50 Mm Thick Rockwool Of 48 Kg/Cum Backing. , 21.4.2Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge.With Brass Cover Plate Minimum 1.25 Mm Thickness , 21.13 Providing And Fixing 100 Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , 50.9.11.1Providing And Fixing Thomson Multi Wood Board Or Equivalent Make Paneling 12 Mm Thick, To Frame, Backing Or Studding With Screws Etc. Complete ( Frames, Backing Or Studding To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 50.9.12.1 Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primer (Fittings To Be Paid Separately) As Per The Direction Of Site Engineer-In-Charge. , 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 13.69.1 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , 13.80Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , 13.83.2Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.47.1Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) , 10.16.3 Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Electric Resistance Or Induction Butt Welded Tubes , Od31981/2023_2024Roofing Sheet With Sandwich Puf Roof Panel With 0.40 Mm Or Nearest Size Pre Painted Galvalume Sheet At Top & Bottom , 30 Mm Or Nearest Size Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete , Od31982/2023_2024 Wall Cladding With Sandwich Puf Wall Panel With 0.40 Mm Or Nearest Pre Painted Galvalume Sheet At Top &Bottom , 30 Mm Or Nearest Puf Sheet At Middle Portion , Necessary Overlap At Ends Including Self Screws, Cyclone Washer Etc. Complete. , Od31983/2023_2024 Providing At All Heights, Levels And Locations 0.45 Mm Thick Galvalume Sheet Of Alloy 31500/31000/40800, Conforming To Is 1254, Is 737, Is 2676. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Ss Screws Of Size 5.5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal, Vertical Or Curved Surfaces I/C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge. The Rate Shall Be Inclusive Of All Screws, Seal, Ridge, Labour, Scaffolding, Machinery For Fixing And Approved Sealant Where Required Etc. But Excluding The Cost Of Purlins, Rafters And Trusses. , 17.81Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand/Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P/S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. , 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , 17.7.1 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps , 50.17.1.2 Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge , 50.17.1.5Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.31 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Od33878/2023_2024 Supplying And Fixing Stainless Steel Mirror Finished H Type Handles Including Material Cost, Conveyance And Fixing Charges Etc Complete. , 50.18.7.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 15Mm Dia 12Kgf/Cm2 -Internal Work- Exposed On Wall , 50.18.7.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf/Cm2- Internal Work - Exposed On Wall , 50.18.8.1.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer- In- Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 12 Kgf/ Cm2 , 50.18.8.4.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 32 Mm Pipe 10Kgf/Cm2 , 50.18.8.9.1Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf/Cm2 , 50.18.9.8.2 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching And Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 75 Mm Dia 4 Kgf/Cm2 , 18.7.2 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer -In-Charge. Internal Work - Exposed On Wall20 Mm Nominal Outer Dia Pipes , 18.7.3Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer -In-Charge. Internal Work - Exposed On Wall 25 Mm Nominal Outer Dia Pipes , 18.8.2Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes& Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20 Mm Nominal Outer Dia Pipes , 18.8.3 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes& Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 25 Mm Nominal Outer Dia Pipes , Od31984/2023_2024 Providing And Fixing 24 Mm Thick Factory Made Pvc Door Shutters Made Of Styles And Rails Of A Pvc Hollow Section Of Size 59 X 24 Mm And Wall Thickness 2 Mm With Inbuilt Edging On Both Sides. The Styles And Rails Mitered And Joint At The Corners By Means Of M.S. Galvanized/Plastic Brackets Of Size 75 X 220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Fixing Galvanized M.S. Tube Of Size 20 X 20 Mm And 1 Mm Wall Thickness. The Lock Rail Made Up Of H Section, A Pvc Hollow Section Of Size 100 X 24 Mm And 2 Mm Wall Thickness,Fixed To The Shutter Styles By Means Of Plastic/Galvanized M.S. U Cleats. The Shutter Frame Filled With A Pvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Fixing Horizontally 6 Mm Galvanized M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge( For W.C. And Bathroom Door Shutter). , Od31985/2023_2024 Supplying And Fixing Name Board Of Various Sizes Using Foam Sheet Board Including Lettering As Per The Direction Of Departmental Officers Including Cost, Conveyance And Fixing Charges Etc Complete. 45X14cm Size , Od31986/2023_2024 Supplying And Fixing The Name Board Of Size 80 X 30 Using Acp Board With Acrylic Lettering Including Cost, Conveyance And Labour Charges For Lettering And Fixing Etc Complete , Od31987/2023_2024 Supplying And Fixing Inaugration Board Using Granite Slab Including Lettering As Per Direction Of Departmental Officers Including Cost Of Granite, Lettering And Fixing Charges Etc Complete. Size: 100X84cm , Supplying And Fixing Skylight Of Size 1.2Mx 1.8M With Designed Acrylic Sheet Including 4 Numbers Led Tube As Per The Direction Of Engineer In Charge , Od31989/2023_2024 Computer Chair The Medium Back Adjustable Revolving Chair Made With Mesh Back Within Built Handle In The Nylon Finish, The Back Is Designed Extra Lumber Support. The Seat Have Provided Seat Cover In Pp Made With 12Mm Hot Pressed Ply And Pu Moylded Foam. The Tilting Mechanism Should Be Synchro-Tilt Mechanism As Per International Ergonomics Standards Any Position Locking. The Base And Pin Wheels Are Made In The Nylon. 120Mm H Gas Lift Should Be Provided With Tower Bellow , Od31990/2023_2024 High Back Chair Made With Feather Foam Seat & Mesh Back With Lumber Support. , The Gas Lift Mechanism Should Be Tested As Per Bifmastandards. The Pedestal Should Be Five Legged Injection Mouldedin Black 30% Glass –Filled Nylon And Fitted With 5 Nos Twin Wheel Castors. The Castors Of The Chairs Should Be Glass Filled, It Should Have Synchro Any Anglelocking Arrangement , Od31991/2023_2024Providing And Fixing Trap Doors For Access To The Areas Above False Ceiling. The Trap Door Shall Have An External Frame Made Of Powder Coated Aluminium Channel On Which The Shutter Is Hinged. Shutter Shall Be Made 3 Mm Thick Acp Sheet Shutter External Frame Of Shutter Made Of Powder Coated Aluminium Channel. Concealed Heavy Duty Hinges Shall Be Used To Mount The Shutters And Locking Shall Be Provided. The Shutter Shall Be Moulded In Level With The False Ceiling Forming A Groove All Around. Sufficient Number Of Hinges And Locks Shall Be Provided To Avoid Sagging Of The Shutter. Key Also Shall Be Supplied. No Extra Rate Shall Be Provided For Suspenders Or Frame Works All Round For Linking The Trap Door To Gyp Board /Any Other False Ceiling. The Rate Including All Labour Charges ,Material Charges Ect Complete. , Od33559/2023_2024 Supplying And Laying Polyster , Washable And Stainfree Cloth(Bio-Active Fabric Washable Germfree-Suitable For Icu Room) Curtain System With Maximum Curtain Cloth Height 230Cm (Top 30 Cm White Colour Net And 200Cm Light Blue Colour As Per Approval) Stitching With Stifiner Tape,Pleats,Ironing And Laying In Icu Room Around Each Bed Using Pvc Runner With Hooks&Stopper For Hanging/Sliding Etc. As Per The Direction Of Engineer In Charge Including Conveyance To Site , Laying In Line And Level , Sealing All Cuttings In False Ceiling With Powder Coated Ms Cup ,All Leads And Lifts Including All Labour Charges Etc. Complete.(Unpleated Length Of The Cloth Maesurement Will Be Considered For Payment Also The Bottom And Top Foldings Will Not Be Considered In Cloth Measuremnet)/Supplying And Fixing Powder Coated 20Mm Dia. Gi Round Tube Hanging Support Of Required Length (App. Length 1.10M) One End Fixing From Slab By Using 6Mm Dia. Expansion Bolt At A Distance Not More Than 2 M, C/C Down End Fixed To Powder Coated Aluminium Channel Frame 45X20mm X1mm Thick Section By Using Ss Screw As Per The Direction Of Engineer In Charge Including Conveyance To Site, Laying In Line And Level ,Sealing All Gaps In False Ceiling Due To Hanging Supports ,All Leads And Lifts, Including All Labour Charges Etc. Complete. , Od33560/2023_2024 Providing And Fixing Vertical Blinds As Per The Direction Of Engineer In Charge , Furniture& Other Works: Lead Lined Door Shutters: 2Mm Lead Lined Door Shutterswithsolid Cored(30Mm) Lead(2Mm) Lined Flush Door Side Hung Two Rebated Shutters With Plywood(6Mm) & Laminated (1Mm) On Both Sides And All Accessories ( Ss Hinges (4 Nos), Tower Bolt , Ss Handles Etc..) , Lead Lined Door Frames: Lead(2Mm) Lined Flush Door Side Hung Single Shutter With Plywood(6Mm) &Laminated (1Mm) On Both Sides And All Accessories(Lead Sheet Should Overlap Door Frame & Wall )Includingproviding Wood Work In Frames Of Doors And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length , Using Good Quality Anjili Wood /Jack Wood (Frame Size 12 Cm X 8 Cm) , Wood Frame For Fixing Lead Glass (Lead Sheet Should Overlap Door Frame & Wall ) , Steel Cupboard (Godrej) For Storage 6Ft Tall 3 Feet Width , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Wiring For Group Controlled (Looped) Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point ( Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 2X 2.5 Sq. Mm + 1 X 2.5Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 4 X 6 Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq.Mm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 2.5Sq. Mmm , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required. 3 X 4 Sq. Mmm , Switches & Sockets: Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 2 Way 5/6 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5/6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15/16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 20/25 Amp Switch , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 20/25 Amp Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Bell Push , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 6 Module (200Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module (125Mmx125mm) , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Ceiling, Wall And Exhaust Fans: Extra For Fixing The Louvers/ Shutters Complete With Frame For An Exhaust Fan Of All Sizes , Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Color Washing Etc. As Required. , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep , Sitc Of 400Mm Sweep Meduim Duty Wall Fans With Metallic Vanes (Make: M/S Almonard/ Crompton/Bajaj Or Equivalent) , Supply, Conveyance, Installation, Testing And Commissioning Of Ceiling Fans Of The Following Sizes Using Standard Accessories Excluding Resistance Type Regulator, Wiring The Down Rod With 16/0.20Mm Pvc Insulated And Pvc Sheathed 650/1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 1200Mm Sweep -5Star Rated Bldc Ceiling Fan Complete With 300Mm Down Rod , Canopies, Shackles And Blades Working On 230V/240V Single Phase A/C , Supply Of 300/305 Mm Sweep Light Duty Exhaust Fan In Metal Frame Working On230 Va/C , Db Mcb Switch Gear: Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8+18) - Three Phase Double Cover (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall, Making Good The Damages, Color Washing Etc. As Required 6 Way (8 + 18) - Double Cover Tpn Vertical Db With Provision For Fixing Mccb As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface/ Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/ Rccb/Isolator)2+12 Way, Double Door , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, (Three Phaseand Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Dbcomplete With Connections, Testing And Commissioning Etc. Asrequired. 63 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 V, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 A Rating, 4 Pole, 30 Ma Rccb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , Supplying And Fixing Following Rating, Three Pole, Mcb63 A Rating, 3 Pole, Mcb , Supplying And Fixing Following Rating, Three Pole, Mcb 40 A Rating, 3 Pole, Mcb , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required 100 Amp, 30 Ka 4 Pole , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required. 16A -100A, 35/36 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Cable Supply Laying And Termination: Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required. Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc.As Required.4 Core 185 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 240 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Aluminum Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 300 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 25 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 50 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 10 Sq Mm With Factory Made Clamp , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 16 Sq Mm With Factory Made Clamp , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 3.5 Core 95 Sq Mm , Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armored Copper Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages, Color Washing Etc. As Required. 4 Core 70 Sq Mm , Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminum Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required. 3.5 Core 70 Sq Mm , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required.225Mm Width X 50Mm Depth X 1.6Mm Thickness , Supplying And Installing Following Size Of Perforated Painted With Powder Coating Ms Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With Ms Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required 225 Mm Width X50 Mm Depth X 1.6 Mm Thickness , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 50 Sqmm , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 70 Sq. Mm (38Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 95 Sq. Mm (45Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 185 Sq. Mm (57Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 3 1/2X 240 Sq. Mm (62Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 10 Sq. Mm (25Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 16 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required. 4 X 25 Sq. Mm (28Mm) , Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Required.4 X 50 Sq. Mm (35Mm) , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.16 Sq.M , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 25 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required.10 Sqmm , Supplying Siemens / Tropodur Type Nickel Plated Double Compression Brass Cable Gland For Pvc Insulated And Pvc Sheathed Armoured Aluminium/ Copper Conductor Cable 1.1 Kv Grade, And Making End Termination Suitable For 2/ 3/ 3½/ 4 Core Cable Of The Following Sizes As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 50 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 35 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 25 Sqmm , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 16 Sq.M , Supply Of Superior Quality Copper Tubular Cable Socket And Making Core Termination Of Cables Of The Following Sizes Including Crimping Etc. As Required. 10 Sqmm , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required.25Sq - 95Sq Mm With 20 Mm Wide X 1.20 Mm Thick Clip , Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Each Size Of Glands For The Following Sizes Of Cables As Required. 4Sqmm-16 Sq Mm With 12 Mm Wide X 1 Mm Thick Clip , Earthing & La: Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 2.65 Mm Copper Conductor (12 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 3.15 Mm Copper Conductor ( 10 Swg) , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 4.00 Mm Copper Conductor ( 8 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 2.65 Mm (12 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 3.15 Mm (10 Swg) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required. 4.00 Mm (8 Swg) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/ Coke And Salt As Required. , Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Color Washing Etc. As Required (For Horizontal Run) 25 X 3 Mm Copper Strip , Supplying, Threading, Laying And Jointing Of The Following Sizes Of B Class Gi Pipe With All Required Accessories In Ground In Trench As Protective Covering To Earth Leads 40Mm Dia , Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection/ Terminating With Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required 2.00 Mm Copper Conductor ( 14 Swg) , Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube,Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Fixing Of Lightning Conductor Finial (Single Prong) With Base Plate Including Holes Etc. Complete As Required , Jointing Copper / G.I. Tape (With Another Copper/ G I Tape, Base Of The Finial Or Any Other Metallic Object) By Riveting / Nut Bolting/ Sweating And Soldering Etc As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Vertical Run) , Fixing Of Copper/ G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Horizontal Run) , Fixing Of Copper/ G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required.(For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required. , Providing And Laying G.L. Tape 32 Mm X 6 Mm From Earth. Electrode Directly In Ground As Required , Laying Copper/ G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Led Fixtures S&F: Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16/0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required 1200 Mm 1X20w Led Lamp With Box Type Fixture , Supply & Installation Of Light Fittings On Tw Round Block
Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thickness Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200Mm 1X20w Led Lamp With Box Type Fixture , Supplying And Fixing Of Recess Mounted Led Luminaire With Full Diffuser Type Upto 36 W (Max), 2X2 Led, Cool White, 5700K, White Powder Coated Crca Housing, Wipro Crco10r038hp57gl1 Or Bajaj Bzrsql 36W Gzi Cw Or Equivalent , Frame For Fixing Recess Mounted Led 2X2 Ft Luminaire 608 Mm X 608 Mm , Supplying And Fixing Ofrecess Mounted Circular Led Retrofit Downlighter, 15W, Powder Coated White Finish, Bpslr 15W Wh Bajaj Or Equivalent , Supplying And Fixing Of 6 / 7 W Pin Type Led Bulb In The Existing Angle Batten Etc As Required (Philips, Wipro Or Similar Superior Make) , Supply Of 18W Led Downlighter With A Nominal System Lumen Output Of Minimu 500 Lumens. System Wattage Should Not Exceed 18W. The Luminaire Shall Have A Rated System Lifetime Of 50,000 Burning Hours. The Luminaire Should Have A Color Temperature Of 5700K And Cri>80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.95. Housing Shall Be Crca Powder Coated With Pmma Diffuser.Driver Shall Have 85% Efficiency. Similar To Wipro Make Ld06-221-Xxx-57-Xxor Eqivalent , Supply Of 12W Led Downlight, High Efficiency With A Nominal System Lumen Output Of 760 Lumens. Luminaire Wattage Should Not Exceed 12W. The Luminaire Should Have Acri > 80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.9. Slim Led Batten In Aluminium Housing And Decorative End Caps. Robust Driver With Wide Voltage Range 100-240 Volts And Inbuilt Protection. Aesthetically Designed Mirror Led Light Fixture Of 4000 K,Of Surface Mounting Which Provides Soft-Light And Glare Free Symmetrical Illumination. Simialr To Model Number Ld07- 131-060-40-Wh Of Wipro Make Or Equivalent. , Fire Alarm, Fire Extinguisher & Safety: Abc Powder Type Fire Extinguisher With Nabl Approval, Fights Class A, B, C And Electrically Started Fires. , Fire Extinguisher Carbon Di-Oxide Type With Nabl Approval , Supplying, Installing, Testing And Commissioning Ofconventionalsingle Action Manual Call Point , Supplying, Installing, Testing And Commissioning Of Conventional Hooter With Builtin Flasher Lightwith Base Ul/En Listed. , Supplying, Installing, Testing And Commissioning Of 2 Core X 1.5 Sqmm Fr Pvc,Multistrand Copper Cu Ar Cable Confirming To Is Standards And Specifications. Make: Polycab / Century , Providing Installating, Connecting, Testing And Commissioning Heat Detectors Type With Mounting Base, Blinking Ledas Required Complete And Integration , Supplying, Installation, Testing And Commissioning Ofconventional Photoelectric Smoke Detectorsas Required To Connect With Existing System , Providing And Fixing Of Response Indicator As Required , Conventional Single -Zone Fire Panel With Batteries, Battery Charger Mimic Diagram Etc , Supply And Providing2/3 Mm Thick Sythetic Type And 1 M Wide Electrical Grade Chequered Type Rubber Mat To Withstand 3.3 Kv Dielectric Strength Conforming To Is 5429/1969. , Supply And Providing Laminated First Aid Chart Duly Framed And Placed In A Conspicuous Location For Clear Vision. , Numbering & Lettering: Numbering Of Ceiling Fan / Exhaust Fan/ Fluorescent Fittings As Required. , Hvac Works: Copper Pipe With Superlon Insulation For Suction And Discharge , Pvc Drain Pipe With Proper Insulation , Weather Proof 3 Core Copper Wire For Indoor To Outdoor Connecting Cable (Size As Per The Requirement Of Ac Manufacturer) , Core Cutting Charges Including Making The Surface Finished With Plastering And Painting, Making Good And Finishing With Matching Surface After Housing Pipe Etc. , Supporting Stand For Fixing Outdoor Unit(Powder Coated) , 4 Kva Voltage Stabilizer Wall Mount Type With Time Delay, High& Low Voltage& Thermal Overload Protection, Input Voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V Guard Vg 500 Or Equivalent , Supply, Conveyance Testing And Commissioning Of 2 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Superior Brands, Cooling Capacity 6000 Kw/Hr With Rotary/Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Supply, Conveyance Testing And Commissioning Of 1 Ton 5 Star Inverter Type, Split Ac Unit With Copper Tube Cooling Coils, 5 Star Rating Bluestar/Lg(Dual Inverter Type)/Voltas/Mitsubishi Or Superior Brands, Cooling Capacity 3000 Kw/Hr With Rotary /Scroll Type Compressors. With Microprocessor Controlled Code Less Remote, Cfm Above 500/450, Led/Lcd Display , Sitc Of 19 Mm Thick Nitrile Rubber For Under Deckinsulation , Charges For Cutting Holes Suitable For Accommodating The Supply Ducts Including Plastering, Color Washing Etc. As Required. , Outdoor Unit Stand With Ribbed Rubber Pads , Electrical Cabling Between Indoor And Outdoor Units, With Required Size Cables/Wires(Havells/Rr Kabel/V-Guard Frls Wires) , Supply, Installation, Testing And Commissioning Upvc Drain Pipe 6Kg/Sq.Cmof Suitable Dia Connecting The Drain Pan Of The Indoor Units To Nearest Drain Point, With 12Mm Thick Closed Cell Elastomeric Insulation As Per Specification , Motorized Volume Control Damper For Individual Operation Of Ductable Split Air Conditioners , Supply And Fixing Of Canvas Connection And Ribbed Rubber Pads As Vibration Isolators , Providing And Fixing Of Thermal Insulation Lining With 13Mm Thick Nitrile Rubber Closed Cell Type With Adhesive, On Supply Duct. , Providing And Fixing Of Acoustic Duct Lining With 10Mm Thick Nitrile Rubber Open Cell Type Inside The Ducts , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminum Continuous Grilles 150Mm High For Return Air As Per Spec , Supply, Installation, Testing And Commissioning Of Powder Coated Extruded Aluminimum Continuous Grilles 150 Mm High For Supply Air With Aluminum Damper As Per Spec , Supply, Installation, Testing And Commissioning Of Volume Control Duct Damper Made Of Extruded Aluminum For Ducts/Collars To Be Provided With Suitable Links, Lebers And Quadrants For Manual Control Of Volume Of Air Flow And For Proper Balancing Of The Air Distribution In The Main Duct Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc., As Per Specifications. , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 24G , Supply, Installation, Testing And Commissioning Of Gss Sheet Metal Ducting For Air Distribution Network From Indoor Unit As Per Ducting Specifications Complete With Angle Flanges ,Supports, Gi Rods , Anchor Bolts ,Gi Nuts And Bolts, Pvc/ Rubber Gaskets Complete With All Fittings , Bends, Transformations, Vanes, Splitter Dampers, Inspection Doors, Plenums, Channels, Rods, Anchor Bolts, Etc To Roof /Truss As Per Is 655. The Job Includes Entire Air Distribution Network And Sizing Of Ducts Also. Thickness: 22G , Supply, Installation, Testing And Commissioning (Sitc) Of 11 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required , Suitable De- Humidifier Units : Extraction At Least 35 Litres/Day, Compresor : Rotary, Air Flow : At Least 220M3/Hr, Reputed Brand, Input 230V Ac , Ssb And Ups Panel:Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh, Incomer 200A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos Out Goings 160 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specifications.Pn Busbar Chamber With Copper Busbar. , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switch Gears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 160A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 125A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos %Icu= 25Ka) - 2 Nos 63A Fp Mccb - 3 Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification. , Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Panel Assembly Made Out Of 1.6Mm Crca Powder Coated Sheet As Required. 320A/400A, 50/55 Ka (Ics=100%Icu), 4 Pole, Current Limiting Type Mccb With Microprocessor Based Release With Overload Setting Of 50 - 100% Having Adjustable Ol & Sc , Statutory Approvals: Charges For Obtaining Electrical Inspectorates Approval Including Scheme Apporval And Final Approval And Regularizing With Kseb , Elv: Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor,Unarmored Telephone Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 2 Pairs , Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Tv Antenna Socket Outlet , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 25Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 32Mm , Supplying And Laying Of Following Pair Armoured Telephone Cable Through Wall/Tray With All Acessories As Required For Complete Installation And As Instructed By Engineer In Charge/Consultant And Making Good All Damages Made For Installation. 5 Pair , Kronebox-Supply,Erection,Testingandcommissioningoffollowingpairkronewithbox Including Mounting Frame, Enclosure Of Isi Grade With Lockable Front Cover With All Accessories Required For For Complete Installation In Wall As Directed By The Engineer In Charge. 10Pair , Supply, Installation, Testing And Commissioning Of Basic User Phone With Necessary Connection As Required For Complete Installation As Directed By The Engineer In Charge. , Supplying And Drawing Of 6 Core Sm Armoured Optical Fibre Cable (Ofc) Through Wall / Tray With All Acessories As Required For Complete Installation And As Instructed By Engineer In Charge / Consultant And Making Good All Damages Made For Installation. , Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required 1 Run Of Cable , Cat 6 Rj 45 Computer Jack Modular Socket Outlet , Supplying And Drawn Of Utp 4 Pair Cat 6A Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required 1 Run Of Cable , Cat 6A Rj 45 Computer Jack Modular Socket Outlet , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 9U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Dismantling Works : Charges For Dismantling The Existing Electrical Installations Complete Making Good The Damages Of The Wall And Conveying The Dismantled Materials To Store Etc As Required. , Cctv & Public Addressing System: Supply, Installation, Testing And Commissioning Of Ip Based 3.6 Mm Fixed Lens, 2Mp Resolution, H.264 / H.265, 1/2.8 Progressive Scan Cmos Day/Night, Ir Dome Poe Enabled Camera,20 To 30 Meters Ir Range, 120 Db Digital Wdr With All Connectors And Necessary Accessories For Mounting In False Ceiling As Required For Complete Installation As Directed By Engineer In Charge. , Ceiling Mounted Speaker - Supply, Fixing, Testing And Commissioning Of Ceiling Mount Metal Grille Speakers With Inbuilt Line Matching Transformer With Power 6W With All Accessories Required For Complete Instllation As Required. , Wall Mounted Speaker - Supply, Fixing, Testing And Commissioning Of Wall Mounted Speakers With Inbuilt Line Matching Transformer With Power 9Wwith A Volume Controller To Adjust The Volume Individually As Per The Requirement With All Accessories Including Wall Mounting Kit Required For Complete Instllation. The Volume Controller Shall Be Fixed Separately As Per The Site Condition For Individual Control. Cost Inclusive Of Necessary Interconnection Including Conduit, Connection Wire Etc , Mechanical Ventillation System: Axial Fans: Supply, Installation, Testing And Commissioning Direct Driven Axial Flow Fans Suitable Formountingonwallorductinstandardgalvanized/Powdercoatedsteelconstructionwith Requiredrating,Static,Singlemotorandflexibleconnectiontoconnectwithducting/Plenum, Louvers With Birdscreen. The Cost Inclusive Of Ducts Required As Per The Layout. 50 - 250 Cfm , Supply, Installation, Testing And Commissioning (Sitc) Of 8.75 Tr X 2 Nos Or Higher Capacity Air Cooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fittings, Idu Ss Drain Pan, As Per Specifications Complete With Suitable Capacity Drive Motor, Air Cooled Condenser With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Supports For Fixing Idu/Odu As Shown In The Drawing, Safety Devices Including Thermal Protector, Pressure Relief Valve , Over Load Relays Single Phase Preventer Etc, Power Wiring(Max 3M From Isolator) And Control Cabling(Indoor To Outdoor),Thermostat Wiring, High-Low Pressure Cut Out,Suitable For Three Phase 440V Supply Etc Complete As Required (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalised, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Busbars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. Ryb Indicating Lamps Led Type 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp Digital Multifunction Meter To Read V,A.Hz,Pf,Kwh Surge Protection Device (Type1+2) Incomer 400A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 200A Copper Tpn Busbar Chamber With Copper Busbar Out Goings 250A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 160A Fp Molded Case Circuit Breaker With Micro Processor Based Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 100 A Fp Mccb Isolator-2Nos 63 A Fp Mccb Isolator-2Nos The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation) , Supply Of Lt Switch Board Cubicle Type, Made Out Of 2 Mm Thick Crca Sheet, Totally Enclosed, Ip42, Free Standing, Wall/Floor Mounting, Dust And Vermin Proof, Powder Coated, Indoor, Compartmentalized, Suitable For Operation On 3 Phase And Neutral , 415 V, 50Hz Ac System With Bus-Bars Extendable On Both Sides, Including All The Necessary Internal Wiring , Suitable Spreader Etc. The Panel Shall Be Fabricated From A Firm Having Cpri Certification With Test Certificates For Similar Panel(Required For Short Circuit Rating, Temperature Rise And Ip Classification) And With Following Switchgears, Metering Instruments And Accessories Etc. Complete As Required As Per Drawing & Specification. 4A Sp Mcb (0-500)V Class 1 With 90 Deg Defl. Scale. (0-200)A Class 1 With 90 Deg Defl. Scale, Voltmeter Selector Switch 200/5 A 5 Va Class .5S Cts On/Off Indication Lamp, Digital Multi-Function Meter To Read V,A.Hz,Pf,Kwh Incomer 250A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) -1 Nos 250A Copper Tpn Busbar Chamber With Copper Busbar. Out Goings 200 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos 125 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 1 Nos. 100 A Fp Molded Case Circuit Breaker With Thermal Release With Ol And Sc Protection Neutral Link (Ics =100%Icu= 25Ka) - 2 Nos. 63 A Fp Molded Case Circuit Breaker - 2 Nos.The Panel Shall Be Top Entry/Exit And Suitable For Termination Of Cable System As Per Sld And Technical Specification (Not Taken For Evaluation)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
19.
Defence #10295943 Price Bid
Tender For Special Repair And Replacement Of Old Unserviceable Ocb To Vcb And Connected Items At Ima Dehradun.; 1 Dismantling HT 11 Mtr SP 55 steel tubular four pole structure ,disconnecting the HT cables, earthing leads/strips incoming and outgoing HT cable of existing size, disconneting/ dismantling the complete GOD system of existing size and taking out the complete structure from the site of any type, lifting transporting the same to storeyard to keep four pole structure in safe custody complete all as specified and directed. 2 Dismantling HT 11 Mtr SP 55 steel tubular two pole structure ,disconnecting the HT cables, earthing leads/strips incoming and outgoing HT cable of existing size, disconneting/ dismantling the complete GOD system of existing size and taking out the complete structure from the site of any type, lifting transporting the same to storeyard to keep four pole structure in safe custody complete all as specified and directed. 3 Supply, installation, testing & commissioning of 11 KV of rating 630 Amps RMU unit outdoor type IP-54 protection duly painted (Paint shade in painted Alu Zn/RAL 7032 on sheet steel for door and covers), SF-6 gas insulated RMU (Ring Main Unit) four way comprising of two (02 Nos) numbers manually operated load break switch for incoming,Two (02 Nos)number Vacuum Circuit Breaker as outgoing, inside SF6 gas filled stainless steel (nonferrous and nonmagnetic grade) tank having minimum thickness 2.5 mm +/- 0.5 mm having IP-67 degree of protection internal are classified 21 KA/ 03 Sec for cable box and tank bothwith painting as per manufacturer specification & leak rate of SF-6 gas less than 0.1%, RMU should be provided with Copper Bus bar, one number fault passage indicator with each incoming and outgoing, mechanism for interlocking arrangements for powered relay complete with all accessories as under :-(a)RMU type installation Outdoor Extensible type, arc proof as per IEC:62271-200 for design, manufacturing and testing. The RMU must have the following features/specifications:- (i)Rated voltage upto - 12 KV. (ii) Rated power frequency withstand voltage - 28 KV. (iii) Rated lightning impulse with stand voltage - should be minimum75 KVP.(iv) Rated current for ring mainfeeder - 630 A. (v)Rated current for VCB feeder - 630 A. (vi)Rated short-time current - 21KA/3 Sec.(vii)Rated short making current - 52.5kA(viii)Ambient temperature - (-1 degree Celsius to +45 degree Celsius). 4 (ix) Degree of protection against accidental contact and ingress of foreign objects must be assured as under:-(a) SF 6 tank : IP-67. (ab) Out door enclosure IP 54.(x)Each load break Switches includes :-(aa) SF6 three position switches with position ON-OFF-EARTH, (ab)Manual operated spring mechanism ON-OFF-EARTH, (ac) Mechanical indicators for position ON-OFF-EARTH, (ad) Mimic diagram at the front facia of RMU, (ae)Capacitive Voltage indicator, (af)Padlocking facility, (ag)Fault passage indicator for Earth Fault.(xi) Each vacuum circuit Breacker includes :-(aa)Manual VCB with position ON-OFF manual spring charging mechnism with in built spiring charging handle, mechanically latched ON/OFF push buttons. (ab)Manual line disconnector with three posotion switches ON-OFF-EARTH, (ac)Numerical relay for Overcurrent and earth fault protection, (ae)Three phase definite time over current and short-circuit protection with variable tripping times (ANSI 50/51), 3 Phase over current protection with selectable inverse time characteristics and definite time short-circuit current) (ANSI 2021), definite, (af)Capacitive Voltage indicator, (ag) Padlocking facility, (ah)Dedicated CTs for protection.(xii)Operating handle - 1 number, (xii) Right angled Cable boots - 3x sets, (xiv)Capacitor(xv) Any Other standard accessories required for efficient operation and PCC foundation of RMU as per OEM recommendations. 5 Disconnecting the HT cables, earthing leads/strips of 11 KV OCBs and taking out the complete OCBs from the site of any type and capacity, lifting transporting the same to storeyard to keep OCBs in safe custody complete all as specified and directed. 6 Supply, installation, testing and commissioning of 11 KV, 630 Amps, 26.3 KA for 3 sec HT vacuum circuit breaker panel for incomer confirming to the IS 13118/1991, IEC 62271-100/200, IAC-AFLR- 25 KA for 1 sec, PM LSC-2B, front accessed comprising of the following equipments :- 7 (a) Min 630 Amps continuous rating copper bus bar droppers and bus bars with heat shrinkable PVC Sleeves. 8 (b) Truck mounted Floor rolling vacuum circuit breaker LK (L&T) equivalent in Siemens/Schneider withend sheet, castle lock and rear extension 9 (c) Motorised spring charging mechanism. 10 (d) Interpanel barrier to prevent arc propagation from one panel/compartment to other. 11 (e) Earthing truck rated for full making capacity with provision for safe and reliable position indicator. 12 (f) Cast resin current transformer, 11 KV, 100/50/5 ± 5 Amps having protection core class IP10, burden of 15 VA and breaking cap of 26.3 KA for 3.0 second - 03 Nos. 13 (g) Cast resin potential transformer, 11 KV/√3/110V/√3, 100 VA/CL 1.0 - 03 Nos with desired capacity PT fuses. 14 (h) Accessories like local remote selector switch, Breaker control switch (T-N-C) space heater with Thermostate DC and AC control Ckt protection through MCB, indicating LED lamps for RYB phases spring charged, DC supply healthy breaker ON/OFF, Breaker in service, Test, Disconnected Position, Annunciator window and hooter. 15 (j) Multifunction meter with RS 485 port. 16 (k) SCADA compatible numerical O/C & Earth fault relay type modbus RTU. 17 (l) Trip ckt supervision (ii) Master trip (ii) Auxiliary relay (iii) Arc flash supervision of circuit breaker (iv) cable and bus bar compartment. 18 (m) Anti pumping relay panel shall have following additional features:- 19 (n) Continuous rated closing/tripping coils. (ii) Integral spring charging handle. (iii) Fully internal arc tested (25 kA for 1 sec) as per latest IEC 62271-200 Norms. 20 (o) In built power pack 24 volt DC as required for protection relays and other equipments/systemr. 21 (p) Breaker shall be provided with following features:- 22 (i) Auxiliary switch with 6 NO + 6NC contacts mounted on the draw out portion of the switchgear. (ii) Position/ cell switch with 3 NO + 3 NC contacts one eact for TEST and SERVICE position. (iii) Auxiliary switch with 4 NO + 4 NC contacts mounted on the stationary portion of the operated mechanically by a sliding lever from the breaker in service position. 23 Supply, installation, testing and commissioning of 11 KV, 800 Amps, 26.3 KA for 3 sec HT vacuum circuit breaker panel for Bus coupler confirming to the IEC 62271-200, IAC-AFLR-25 KA for 1 sec, PM LSC-2B, front accessed comprising of the following equipments :- 24 (a) 800 Amps continuous rating copper bus bar. Droopers and busbars shall be Raychem insulated. 25 (b) Truck mounted Floor rolling vacuum circuit breaker LK (L&T) equivalent in Siemens/Schneider withend sheet, castle lock and rear extension 26 (c) Motorised spring charging mechanism. 27 (d) Interpanel barrier to prevent arc propagation from one panel/compartment to other. 28 (e) Earthing truck rated for full making capacity with provision for safe and reliable position indicator. 29 (f) Accessories like local remote selector switch, Breaker control switch (T-N-C) space heater with Thermostate DC and AC control Ckt protection through MCB, indicating LED lamps for RYB phases spring charged, DC supply healthy breaker ON/OFF, Breaker in service, Test, Disconnected Position. 30 (g) Antipumping relay panel shall have following additional features:- 31 (h) Continuous rated closing/tripping coils. (ii) Integral spring charging handle. (iii) Fully internal arc tested (25 kA for 1 sec) as per latest IEC 62271-200 Norms. (iv) Racking in/out, Manual closing/tripping of the CB with compartment door closed. 32 (j) Breaker shall be provided with following features:- 33 (i) Auxiliary switch with 6 NO + 6NC contacts mounted on the draw out porition of the switchgear. (ii) Position/ cell switch with 3 NO + 3 NC contacts one each for TEST and SERVICE position. (iii) Auxiliary switch with 4 NO + 4 NC contacts mounted on the stationary portion of the operated mechanically by a sliding lever from the breaker in service position. 34 Note for item No. 5 and 6:-(a) Electrical and mechanical interlocking between all incoming breaker and bus coupler to avoid double supply in outgoing breakers.(b) The VCB should be matched with existing VCB/OCBs including Adopter panel required for connection with existing panel, extension of bus bar and weather proof bus duct, nuts bolts and painting with colour etc as required at site complete all as specified and directed.(c) Contractor shall submit the drawing as per CA specification to Garrision Engineer before placing orders to original manufacturers of panels.(d) Minor items/parts required for making connections in respect of incoming outgoing and earthing etc are deemed to be included in the quoted rates by the contractor.(e) The VCB should be tested at site after insatallation with primary injection system according to the load of feeders and submit the test report of all VCB before pre commissioning in booklet form, cost of the same included in the quoted rate. 35 Supply, laying, jointing and testing cable XLPE insulated screened PVC bedded galvanizedsteel strip or wire armored, electric power cables (Heavy duty) 11000 volts grade with stranded aluminum conductor of cross sectional area 3 core 120 sq mm complete all as specified and directed. 36 Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm complete all as specified and directed. 37 Material and labour for PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in VCB fondation complete all as specified and directed. 38 Material & labour GI tube light grade 100 mm for protection ofUG cable including dismantling complete all as specified and directed. 39 Supply and fixing HT cable root indicator of cast iron embedded in PCC 1:3:6 type C-2 (using 20 mm graded stone aggregate) of size 100x100x200 mm foundation upto ground level including necessary earth work in any type of soil complete all as specified and directed. 40 Material and labour for earthing with steelearth plate electrode ofsize 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32 X 6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed. 41 Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth in soft/lose soil for laying cable/taking out under ground cable, GI pipes and bricks laid under cable and getting out in soft/loose soil complete all as directed. 42 Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick in soft/lose soil after cable/pipes are laid and tested complete all as directed. 43 Removing the excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as directed. 44 Material and labour for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete all as directed. Note:- sand will be measured after punning 8 cm. 45 Material and labour for un-reinforced precast concrete cable cover HV type I, flat size 300 mm X 180 mm X 40 mm as protection to underground cable laid dry and flat adjoining each other complete all as directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
Uttarakhand View Result →
20.
Civil Aviation #10292355 Price Bid
Tender For Miscellaneous Electrical Works At Datia Airport.; 1 Design, Supply, Installation, Testing and Commissioning of FAA compliant, indoor type Micro- processor based Constant Current Regulator(CCR) suitable for remote as well as local control operations with 5 position brightness control (6.6A maximum current corresponding to 100% brightness) on input voltage 230/415 V, 50 Hz., AC supply, provision for control supply with all switchgears, CCR protections, connection/ inter-connections etc. and confirming to tenders technical specifications complete as required.a) 4 KW, 6. 6A output current. 2 Supply of single core x 6 sq. mm sizes 5 KV grade PVC insulated & PVC sheathed, antitermite & anti- rodent,multi-strandedcopperconductorsinglecoreairfieldlightingcableconfirmingtoIS 1554 (Part II) with up to date amendments complete as required. 3 Supply of 4 core x 25 Sqmm. XLPE insulated PVC sheathed armoured aluminium conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required. 4 Supply of 3 core x 16 Sqmm. XLPE insulated PVC sheathed armoured aluminium conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required. 5 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) 6 Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 5 KV grade of 6 sqmm size in the existing RCC/GV/ DWC HUME/ METAL pipe etc. as required. 7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 8 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Up to 35 sqmm 9 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Up to 35 sqmm 10 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Up to 35 sqmm 11 Supply of 5 KV grade plug and receptacle ,suitable for field attachment with 5 KV grade PVC insulated, PVC sheathed single core 6 sq. mm copper conductor AGL cable complete etc. as required. 12 Making connections of 5 KV grade, 6 Sq. mm Copper conductor AFL cables withplug and receptacle connector i/c crimping & fixing, applying HT tape complete as required. 13 SITC of Mini Remote Control Desk havingprovision for control of PAPI both side landing T and windsock and 1 CCR spare i/c MIMIC display etc. complete as required. 14 Supply and fixing of 24 core X 1.5 Sq. mm Copper conductor armoured 1.1 KV grade XLPE insulated PVC Sheathed control cable as per IS 7098 Part-1 1988 as amended upto date as per site requirement. 15 Supply, Erection and termination CRCA sheet 3mm powder coated control cable end termination junction box to be mounted on wall 300mm X 200 mm X 500mm 16 Earthing with G. I. pipe 4.5 m long x 40 mm dia. (Drilling of 300 mm dia, 4.5 Mtr deep by using Borewell machine) including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. includingcharcoal or coke and salt complete as required. 17 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 18 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections complete etc. as required. 19 Supplying and fixing following DB- Phase Segregated DB 12 Way Double Door 8 Incomer 4+4+4 Sub Incomer 12+12+12 Outgoing, of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted, IP54 including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 20 Supplying and fixing distribution board of 12way double door SP, steel sheet for 230 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 21 Supplying and fixing 63 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A TPN MCB 22 Supplying and fixing 32 amps rating, 240/415 volts, C curve, Double Pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 23 Supplying and fixing following rating, two pole,230 volts, residual current circuit breaker (RCCB), having a sensitivity current30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 A 24 Supplying and fixing 6 amps rating, 240volts,10kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 25 Supplying and fixing 16 amps rating, 240volts,10kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 26 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 27 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 28 Wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 29 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 no. 5 pin 5/6 A & 1 no. twin 6/16 A modular socket outlet and 1 no. 5/6 A & 1 no. 15/16 A modular switch, connections etc. as required. 30 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no. 5 pin 5/6 Amodular socket outlet and 2 no. 5/6 Amodular switch, connections etc. as required. 31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 no. twin 6/16 A modular socket outlet and 1 no. 15/16 A modular switch, connections etc. as required. 32 Supply of energy efficient 5 star rated BLDC ceiling fan, 1200 mm sweep remote operated suitable for operation on 240V, 50Hz A.C. supply with down rod canopies etc. complete as required. (Maximum power consumption - 28W) 33 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 34 Supply of energy efficient wall fan Hiflo Wave Plus 60W KD White Wall Fan Sweep: 400 mm suitable for operation on 240V, 50Hz A.C, complete as required. (Maximum power consumption - 60W) 35 Installation, testing and commissioning of wall mount fan, including wiring with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. complete as required. 36 Supply of 230 mm sweep metallic exhaust fan suitable for operation on 240V, 50Hz A.C. supply, 1400 rpm with all accessories including louvers, shutters etc. complete as required. 37 Installation of exhaust fan of size 230 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 38 Supply of minimum 15 Watt recessed mounting LED downlight with minimum output 1500 lumens suitable for 140-270 V, AC, 50 HZ, PF>0.95, luminaire should have extruded aluminium / CRCA / Extended alloy housing. Luminaire should have proper thermal management, Min IP protection should be IP 20. Total power consumption of fitting (including driver loss) should not more than 110 % of rated capacity of LED Light fitting, complete with all accessories as required. 39 Supply of minimum 30 W LED recessed 2ft X 2ft luminaire with minimum output 3000 lumens suitable for 140-270 V, AC, 50 HZ, PF>0.95, luminaire should have extruded aluminium / CRCA / Extended alloy housing. Luminaire should have proper thermal management, Min IP protection should be IP 20. Total power consumption of fitting (including driver loss) should not more than 110 % of rated capacity of LED Light fitting, complete with all accessories as required. 40 Supply of minimun 40 W LED street light fitting with minimum output of 4400 lumens suitable for 140-270 V, AC, 50 HZ, PF>0.95, luminaire should have High pressure die cast Aluminium /Standard alloy housing. Luminaire should have Air vents in housing for proper thermal management, Min IP protection should be IP 65. Total power consumption of fitting (including driver loss) should not more than 110 % of rated capacity of LED Light fitting, complete with all accessories as required. 41 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent / LED Fittings of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 42 Supply, Installation, Testing & Commissioning of 2 Ton (5 Star) Inverter Split Air conditioning unit fittedwith rotary compressor alongwith indoor/outdoor units, gas R-410A or eco-friendly gassuitable to operate on 230V +/- 10%, 50 Hz, single phase AC power supply capable of performing the function as Dehumidification, air circulating and filtering complete with compressor, evaporators, air cooled copper condenser connected refrigerant piping (upto 10 feet) electrical wiring including MS stand suitable for outdoor unit with all accessories complete etc as required. 43 Supply, Installation, Testing & Commissioning of 1.5 Ton (5 Star) Inverter Split Air conditioning unit fittedwith rotary compressor alongwith indoor/outdoor units, gas R-410A or eco-friendly gassuitable to operate on 230V +/- 10%, 50 Hz, single phase AC power supply capable of performing the function as Dehumidification, air circulating and filtering complete with compressor, evaporators, air cooled copper condenserconnected refrigerant piping (upto 10 feet) electrical wiring including MS stand suitable for outdoor unit with all accessories complete etc as required. 44 SITC of Floor Standing RO Purifier Chiller & Dispenser having RO + UF + TDS Control with minimum Flow Rate 30L/hr and storage 20L Tank complete as required 45 SITC of 1.5kVA stand-alone solar power system having 3no. 530Wp monocrystalline solar panel,1no. 24V 1.5kVA solar inverter with MPPT feature, 2no. 150Ah solar tubular batteries, complete with DCDB box, earthing, Lightning arrestor installation and module mounting structure and associated all cabling complete etc. as required.Preferred make-TATA POWER or equivalent. 46 Supply of 3 core x 4 Sqmm. XLPE insulated PVC sheathed armoured copper conductor cable of 1.1 KV Grade confirming to IS:7098 (Part 1) with upto date amendment etc. complete as required. 47 Supply, Installation, Testing and Commissioning of following 5 H.P. 3 Phase 100 mm water cooled Borewell Submersible pump set- with associate accessories. 48 Supply, Installation, Testing and Commissioning of following 5 H.P. 3 Phase 6-10A DOL water cooled Borewell Submersible Pump Starter with associate accessories. 49 Supply, Installation, Testing and Commissioning of following sizes of CI butterfly valve conforming to API-594 with C.I. body, SS Disc, SS stem, EPDM seal, complete with companion flanges, bolts, nuts, washers & inserted rubber gasket complete as required 50 150 mm dia. 51 100 mm dia. 52 80 mm dia. 53 Supply, Installation, Testing and Commissioning of following sizes of C- class heavy duty Mild Steel pipes conforming toIS-1239/ IS-3589, including cutting, welding, nut-bolts, gasket, fitting viz. bends, tees, reducers, crosses, flanges etc. and fixing the pipes onwall / ceiling / beam / floor with suitable MS clamps / structural supports/PCC block and painting complete as required and as per enclosed specification. 54 150 mm dia. 55 100 mm dia. 56 80 mm dia. 57 Supply, Installation, Testing and Commissioning of MS structural support for Above ground piping and pump room manifold 58 Supply of fracture bed designed to provide firm, even support for patients with fractures. Bed to be made of mild steel with a powder-coated finish having features for allowing for changes in height and position and includes wheels for easy mobility within the hospital setting 59 Supply of healthcare semi fowler bedmade of mild steel with a powder-coated finish having feature to bend bed from mid. 60 Supply of suitable semi fowler 2 section mattress for healthcare bed with minimum 4inch thickness. The mattress to have non hygroscopic outer cover which is easy to clean such as artificial leather cover.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
Madhya Pradesh View Result →
21.
Educational and Research Institute #10170414 Price Bid
Tender For Re-Wiring In Corporate Office Nit Hamirpur.; 1 Providing and Fixing of LED recessed mounted circular down light 15/18 watt make Halonix , philips, Bajaj, Panasonic, Wipro,CromptonGreaves. and6 inch dia (152.4 mm) including entire carriage of matriallead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 2 Providing and Fixing of Ceiling fan 1200 mm sweepwith BLDC moter fan with remote controlmake Usha, Bajaj, Crompton Greaves. including entire carriage of matriallead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. including entire carriage of matriallead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 4 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 5 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 6 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 7 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)including entire carriage of matrial lead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 8 8 way (4 + 24), Double door 9 12 way (4 + 36), Double door 10 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. including entire carriage of matriallead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 11 63 A 12 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i/c entire carrige of matrial all lead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 13 Single pole 14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required including entire carriage of matriallead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 15 40 A 16 FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL) 17 Supplying, and Fixing installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. including entire carriage of matrial lead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 18 Supplying,and Fixinginstallation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required including entire carriage of matrial lead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 19 Providing and Fixing of4 Zone 20 INTELLIGENT FIRE ALARM SYSTEM 21 Supplying and Fixing, installation, testing & commissioning of fault isolator complete with base as required. including entire carriage of matriallead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 22 Supplying, and Fixing installation, testing & commissioning of fire hooter.including entire carriage of matriallead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 23 Supplying, and commssioning of main 12 way Electrical panel of size 1.80 x1.20 mtrs with vertical copper bus- bar and wiring from bus -bar to MCCBs including volt meter, Ampere meter, three RYB phasc indicatorand control MCB ( excluding MCCBs ) including entire carriage of matriallead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 24 Supplying and Fixing, 4 pole MCCB of ligrand/ MDS make DPX3 type of flowing rating in the elctrical main control panelto the best satisfation of Engineering -in- charge. i/c entire carrige of matriallead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 25 4 pole 40 Amp ,16KA 26 4 pole 63Amp ,16KA 27 4 pole 250Amp ,25 KA 28 Providing and Fixing heat shrinkable jionting kit of 1100 volt 3.5x120 sq mm cable as required at site including entire carriage of matrial lead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 29 Providing and Fixing of PVC insulated and PVC sheathed/ XLPE,armoured aluminium conductor power cable 1.1 KV grade of 3.5 core 35 sq mm in existing PVC pipe as per required of KEI/ Havells/ Plaza make including entire carriage of matriallead , lift,height andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 30 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required including entire carriage of matriallead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in -charge. 31 3½ X 35 sq. mm (32mm) 32 Providing and Fixing PVC insulated single core following size industrial multistrand cables FRLS copper conductor for voltage grade up to 1100 volt of KEI/ Plaza/ Havells make including entire carriage of matrial lead , lift,hight andcostof all other insidentals to the best satisfaction of Engineer-in - charge. 33 25 Sq mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Himachal Pradesh View Result →
22.
Heavy Industries and Public Enterprises #10031945 AOC
Bids Are Invited For Afps System Cabinets, Make-Werner , Events Documenting - Printer Stands, Make- Werner , Ep Desk, Make- Werner , Control Desk, Make- Werner , Three Section Desk - Panel Safety Systems, Make - Werner , Generlized Mimic Panels Of The Reactor, Make - Werner , Key Switch, Werner Part Code --50 X 50Mm, 9025.Ft-45-42.11.00 , 12-Pos Switch - 50X50mm, Werner Part Code 50 X 50 X 50Mm- 2, 9000-43-10Pos , Control Board -3 Push Buttons, Werner Part Code - 25X 50Mm X 50 Mm - 9025.Ft-03-3Pb Rnd , Control Board - 2 Push Buttons, Werner Part Code -25 X 50 X 50Mm, 9025.Ft-02- 2 Pb Rnd , Multi Position Switch, Werner Part Code - 25X50mm, 9025.Ft-43 -Spl-Ms-Pot , Control Board - 3Leds-Square - Green And Switch 2Pb, Werner Part Code -50 X 50 X 50Mm 9025.Ft-45-16.11.00-3Led-Rnd-Gyr - Czm , Control Board - 1 Leds-Sqaure - Green And 2 Position Switch , Werner Part Code -50 X 50 X 50Mm 9025.Ft-45-30.11.00-1Led-Sqr , Control Board 2 Leds-Sqaure - Yellow And 2 Position Switch 2Pb, Werner Part Code -50 X 50 X 50Mm 9025.Ft-45-16.11.00-2Led Rnd , Indicator Board - 2Leds-Square - Green And Yellow Selector Switch, Werner Part Code -50 X 50X 50Mm 9025.Ft-45-16.11.00-2Led-Sq-Gy , Control Board -Cool Down Rate Switch With 2 Push Buttons, Werner Part Code - 25 X 50 X 50Mm 9025.Ft-21-2Pb , 1 Position Switch, Werner Part Code -50 X 50 X 50Mm 9025.Ft-45-30.11.00 , Control Board - 2 Position Switch, Werner Part Code -50 X 50 X 50Mm 9000.Ft-45-14-11.2Led , Control Board -2 Leds-Square - Yellow And 2 Position Switch, Werner Part Code -50 X 50 X 50Mm 9025.Ft-45-16.11.00-2Led Sq , 2 Pos Up Arrow Indicator, Werner Part Code - 50X 50X50mm Czm-2Pos-Up-Arrow , Indicator Board Up Ward Direction Arrow Werner Part Code -25 X 50 X 50 Mm 9025.Dfdl.04- Y Il-24Vdc -Arrow , Indicator Board Up Ward Direction Arrow Werner Part Code -25 X 59Mm 9025.Dfdl.04- G Il-24Vdc - Arrow , Indicator Board Radiation Symbol Werner Part Code - 25 X 50 Mm X 50Mm 9025.Dfdl.06--Czm Fan , Indicator Board Rigth Ward Direction Arrow, Werner Part Code -50 X 50 X 50Mm 9025.Dfdl.06 -Czm , Indicator Board Left Ward Direction Arrow, Werner Part Code -50 X 50 X 50Mm 9025.Dfdl.06-Czm , Indicator Board Downward Direction Arrow, Werner Part Code -50 X 50 X 50Mm 9025.Dfdl.06-Czm , Control Board 3Leds-Round- Red, Green, Yellow - And 3 Push Button, Werner Part Code -25X50x 50Mm 9025.Ft-33 - 3 Rnd Led - Gry- 3 Pbrnd , Control Board 3Leds-Round -Green, Yellowand Red And 3 Push Buttons, Werner Part Code -25X50mm 9025.Ft-33 - 3 Rnd Led- Gry- 3 Pbrnd , Control Board 3Leds-Round-Green, Yellow Red And 2 Push Buttons, Werner Part Code -25X50mm 9025.Ft-33 - 3 Rnd Led Gry - 3 Pbrnd , Control Board 3Leds-Round-Green, Yellow And Red And 2 Push Buttons, Werner Part Code -25X50mm 9025.Ft-33 - 3 Rnd Led- 3 Pb Rnd , Control Board 3Leds-Round- Red, Square-Green, Yellow And 2 Push Buttons, Werner Part Code -25 X 50X 50 Mm 9025.Ft-32 -Sq-2-Rnd-1Note- 2 Square Led-G-Y, 1 Round Led - 2Pb Rnd , Control Board 3Leds-Round- Red, Square-Green, Yellow And 2 Push Buttons, Werner Part Code-25 X 50Mm 9025.Ft-32 -Sq-2-Rnd-1Note- 2 Square Led -G-Y, 1 Round Led - 2Pb Rnd , Control Board 2Leds-Squaregreen, Yellow And 2 Push Buttons, Werner Part Code - 25 X 50Mm 9025.Ft-22- 2Sqled -G,R - 2Pbrnd , Control Board 2Leds-Round-Green And Yellow And 2 Push Buttons, Werner Part Code -25X50mm 9025.Ft-33 - 2 Rnd Led - Gy- 2 Pbrnd , Control Board 2Leds-Round-Yellow And 2 Push Buttons, Werner Part Code - 25 X 50Mm 9025.Ft-22- 2Rndled -Y - 2Pb Rnd , Control Board 2 Leds-Round-Yellow And 2 Push Buttons, Werner Part Code - 25 X 50Mm 9025.Ft-22- 2Rndled - Y- 2Pbrnd , Control Board 1 Led-Round-Red And 2 Push Buttons, Werner Part Code -- 25 X 50Mm 9000.Ft-12 1 Rnd Led-2Pb Rnd , Control Board 3Leds-Round Red ,Green, Yellow And 1 Push Buttons, Werner Part Code-25X50mm 9025.Ft-33 - 3 Rnd Led - Rgy- 1 Pbrnd , Control Board 3Leds-Round Red, Green, Yellow And 1 Push Button, Werner Part Code - 25X50 X 50Mm 9025.Ft-33 - 3 Rnd Led - Rgy- 1 Pbrnd , Control Board 2Leds-Square-Green, Yellow And 1 Push Buttons, Werner Part Code -25X50mm 9025.Ft-33 - 2 Sq Led - Gy - 1Pbrnd , Control Board 3Leds-Round-Yellow And 3 Push Buttons, Werner Part Code - 25X50mm 9025.Ft-33 - 3 Rnd Led - Y- 3 Pb , Control Board 1 Push Button, Werner Part Code - 25 X 50Mm 9025-Ft-10 By 1 -1 Pb Rnd , Control Board 2 Leds Round, Green,Yellow And 1 Push Buttons, Werner Part Code-25 X 50X 50Mm 9025.Ft-21-2 Led-Y-1Pb , Control Board 2 Led Round,Yellow And 1 Push Button,Werner Part Code-25X50x50mm 9025.Ft-21-2Led-Y-1Pb , Control Board Black Push Button, Werner Part Code - 50 X 50 X 50 Mm 9025.Ft-45-10.11.05 , Control Board Blue Push Button, Werner Part Code - 50 X 50 X 50 Mm 9025.Ft-45-10.11.05 , Control Board Acknowledge-Black- Push Button, Werner Part Code -50 X 50Mm 9025.Ft-45-10.11.00 , Control Board Confirmation-Blue- Push Button, Werner Part Code -- 50 X 50Mm 9025.Ft-45-10.11.06 , Indicator Board Fire - Fighting Push Button, Werner Part Code -50 X 50 X 50 Mm 9025.Ft-45-10-11.005 With Protection Guard , Control Board Push Button Black, Werner Part Code - 50 X 50 X 50 Mm 9025.Ft-45-10-11.005With Protection Guard , Control Board Push Button With Cover, Werner Part Code 50 X 50 X 50 Mm 9025.Ft-45-10-11.005 With Protection Guard , Control Board Push Button, Werner Part Code - 50 X 50 X 50 Mm 9025.Ft-45-10-11.005 With Protection Guard , Control Board Push Button , Werner Part Code - 50 X 50 X 50 Mm 9025.Ft-45-10-11.005 With Protection Guard, , Control Board Protective 1 Push Button, Werner Part Code-- 50 X 50 X 50 Mm 9025.Ft-45-10-11.005 With Protection Guard , Control Board 2 Position Switch, Werner Part Code -50 X 50 X 50Mm 9025.Ft-45-16.11.00-2Led , Control Board Push Button Werner Part Code - 50 X 50 X 50 Mm 9025.Ft-45-10-11.005 With Protection Guard , Control Board Push Button, Werner Part Code - 50 X 50 X 50 Mm 9025.Ft-45-10-11.005 With Protection Guard , Control Board 3 Position Switch, Werner Part Code -50 X 50 X 50Mm 9025.Ft-45-32.11.00 - 1No Plus 1Nc , Control Board Start Or Stop Push Button, Werner Part Code-- 50 X 50 Mm X 50 Mm 9000.Ft-45-14- 11. 2Led , Window Annuciator Module 25X100mm, Werner Part Code -25X 50X 50Mm - 2 -9025.Lbb-01 1Ledw , Window Annuciator Module 25X50mm, Werner Part Code -25X 50X 50Mm-9025.Lbb-01-1Ledw , Window Annuciator Module 25X50mm, Werner Part Code -25X 50X 50Mm-9025.Lbb-01-1Ledw , Double Window Anuciator, Werner Part Code -25X 50X 50Mm -1 - 9025-01-2Lbb Wh , Double Window Annuciator Module Strip 25X50mm - G,R, Werner Part Code 25 X 50Mm 9025-Lb-02-2Led Red Or Green 7 X15mm , Double Window Annuciator Module Strip 25X50mm - G,R, Werner Part Code 25 X 50Mm 9025-Lb-02-2Led Red Or Green7 X15mm , Single Window Annuciator Yellow, Werner Part Code 25 X 50Mm 9025-Lb-01-1Led Yellow 7 X15mm , Double Window Anuciator, Werner Part Code 25 X 50Mm9025-Lb-02-2Led Yellow 7 X15mm , Double Window Anuciator, Werner Part Code -25X 50X 50Mm - 1- 9025-01-2Lbb Yw 7 X 15Mm Y By G , Single Window Annuciator Green, Werner Part Code25 X 50Mm 9025-Lb-01-1Led Green 7 X15mm , Indicator Board-Leds-Round - Yellow Inscription, Werner Part Code -25 X 50 X 50Mm 9025.Ft-10- 3 Led - Czm , Indicator 2 Led Yellow Rcp Tripping Board, Werner Part Code 25 X 50 X 50 Mm 9025-Ft-12-2Led Vertical , Control Board 1 Led-Round-Yellow Cooling System, Werner Part Code 25 X 50 Mm 9025-Ft-10-1Led Vertical , Indicator Board -2Leds-Square-Green And Yellow, Werner Part Code 25 X 50Mm 9025-Ft-20-2Led Gy , Indicator Board 2Leds-Square-Green And Yellow, Werner Part Code 25 X 50Mm 9025-Ft-20-2Led Gy , Indicator Board 2Leds-Round -Green, Yellow, Werner Part Code 25 X 50 X 50Mm 9025-Ft-20 - 2Led Yg , Control Board -2 Leds-Round, Green, Werner Part Code 25 X 50 X 50Mm 9025-Ft-20 - 2Led Gg , Indicator Board-3Leds-Round Red, Square-Green, Yellow, Werner Part Code 25X 50Mm 9025-Ft-30 - 3Led Gsq-Rrnd-Ysq , 3 Led-Vlv R,R,R Round -Green, Yellowand White - 25X50mm, Werner Part Code -25 X 50X 50Mm 9025.Dfdl.06 - Czm , Indicator Board -1Led Round Red, Werner Part Code -25 X 50 X 50Mm 9025.Ft-10- 1 Led - Czm , Indicator Board -1Led Round - Red Earth Fault, Werner Part Code -25 X 50 X 50Mm 9025.Ft-10- 1 Led -Czm , 2 Led-Vlv S,S -Square - Green, Yellow - 25X50mm, Werner Part Code -25 X 50Mm 9025.Dfdl.06--Czm , Control Board - 1Led Square - Green Push Button, Werner Part Code -50 X 50 X 50Mm 9025.Ft-45-10.11.00-1Led , Control Board - 1Led Square -Green Push Button, Werner Part Code -25X50 X 50 Mm 9025.Ft-33 -1 Sq Ledg- 1 Pbrnd , Control Board - Auto Or B116 Manual Push Button, Werner Part Code - 50 X 50 X 50Mm 9025.Ft-45-14-11.2Led , Indicator Board - 2Leds-Square Yellow, Werner Part Code 25 X 50Mm 9025-Ft-20-2Led Yy , Indicator Board - 2Leds-Round Yellow, Werner Part Code 25 X 50 X 50Mm 9025-Ft-20 - 2Led Yy , Control Board Auto Or Manual Push Button, Werner Part Code 50 X 50 X 50Mm 9025- 45.30.10.11 - 1No Plus 1Nc Total Quantity : 856
Contract Date: Ref. Documents Contract Value : 7.92 Crore
Boards / Undertakings / PSU No of Bidders 1
23.
Educational and Research Institute #10000242 AOC
Tender For Construction Of Ctvs Transplant Ward In Aiims Raipur; 1 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 2 Centering and shuttering including strutting, propping etc. and removal of form for 3 Lintels, beams, plinth beams, girders, bressumers and cantilevers 4 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5 Thermo-Mechanically Treated bars of grade Fe-500D or more. 6 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 7 Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level. 8 Cement mortar 1 : 3 (1 cement : 3 coarse sand) 9 Providing and fixing 15-17 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias, skirtings and similar locations of required size, approved shade, colour and texture laid with epoxy resin based adhesive, joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, cleaning, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite stone slab colour black, Cherry/Ruby red and any size: 10 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 11 40 mm 12 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 13 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 14 250x16 mm 15 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 16 200x10 mm 17 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 18 Twin rubber stopper 19 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 20 Double strip (horizontal type) 21 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 22 Providing and fixing to existing door frames. 23 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 24 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 25 100mm 26 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineerin- charge.(Payment of providing and fixing auto closing hinges shall be paid separately) 27 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge 28 200 mm 29 Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. 30 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 31 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 32 Size of Tile 600x600 mm 33 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 34 110 mm diameter 35 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mmmade out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, lightfittings, fixtures, smoke detectors etc., wherever required. 36 Main ‘T’ runners to be suspended from ceilingusing G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dashfasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted withpolyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. 37 12 mm cement plaster of mix : 38 1:6 (1 cement: 6 fine sand) 39 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 40 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 41 Two coats 42 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge 43 In cement mortar 44 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. 45 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 46 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 47 W.C. pan with ISI marked white solid plastic seat and lid 48 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 49 White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap 50 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 51 Size 600x450x200 mm 52 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 53 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 54 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 55 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 56 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge. 57 50 mm nominal dia Pipes 58 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 59 20 mm nominal dia Pipes 60 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 61 25 to 40 mm nominal bore 62 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 63 20 mm nominal bore 64 Providing and fixing uplasticised PVC connection pipe with brass unions : 65 45 cm length, 15 mm nominal bore 66 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 67 15 mm nominal bore 68 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 69 15mm nominal bore 70 Providing and fixing PTMT grating of approved quality and colour. 71 Circular type 100 mm nominal dia 72 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 73 For fixed portion.Powder coated aluminium (minimum thickness of powder coating 50 micron) 74 For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately)Powder coated aluminium (minimumthickness of powder coating 50 micron) 75 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. 76 Pre-laminated particle board with decorative laminationon both sides 77 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketn etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 78 With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm) 79 Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 80 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixedm with water proofing cement compound @ 0.126 kg/sqm. Thislayer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 81 Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete : 82 Providing and fixing in position Double bay stainless steel (304 grade) scrub station of size 1220x610x1500 mm with automatic sensor & foot operated tap with hot and cold water temperature controller valve and foot operated soap dispenser arrangement of approved make and quality as per the direction of engineer in charge. 83 Providing and fixing 44 mm thick HPL (Hinge Pressure Laminate ) Hermetic Hinge single Leaf Door for civil opening 1800(W)x2100 (H) with S.S. Ball bearing hinges , D Handles , both side key operation dead lock ,View window size 300x300 mm ,sealing gasket, Automatic Drop seal ,door seal and one door closer etc. all complete as per instructions of Engineer In charge. 84 Providing and fixing frosted film of make 3M/Avery/Oracal and of thickness not less than 1 mm over the glass of windows, glass partition etc including cutting of film in a certain design, shape all complete as per the instructions of Engineer In charge. 85 Providing and applying anti microbial epoxy PU flooring of thickness not less than 3 mm, in required colour, patterns etc. having anti skid properties,corners should be uniformly curved, final surface should be non corrosive to biological fluids, detergents etc. all complete as per the instructions of Engineer In charge. The execution of item shall involve activities of cleaning the surface, grinding of the cleaned surface by manual or mechanical means, applying PU flooring primer on the complete surface followed by screed activity to level the complete surface and then followed by applying PU Topcoat. The items to be used shall be of make BASF/ENDURA/MYK failing which the make approved by Engineer-in Charge shall be used. The work is to be executed and completed all as per manufacturers specification and as per direction of Engineer-in Charge. 86 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 87 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 88 Using M.S. angels 40x40x6 mm for diagonal braces 89 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 90 In stringers, treads, landings etc. of stair cases, includinguse of chequered plate wherever required, all complete 91 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 92 10 x 120 mm 93 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 94 1:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources) 95 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. 96 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 97 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 98 Providing and fixing 50 mm thick galvanised Puf panel of make Jindal/Tata/JSW on the walls and roof (size, shape and pitch of corrugation as approved by Engineer-in-charge) . The sheet shall be fixed using self drilling /self tapping screws of required size with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces,including cutting to size and shape wherever required, Fixing operations of roof/wall panels shall be completed in all respect as per drawings and manufacturers specifications and under the overall direction of the Engineer-in-charge.Drawing and Layout of Puf Panel is to be submitted by the contractor for the approval of Engineer-in Charge. No separate amount is to be paid by the department to the contractor for drawing/layout 99 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit & accessories as required. 100 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 101 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 102 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 103 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 104 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 105 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 106 5/6 A switch 107 15/16 A switch 108 3 pin 5/6 A socket outlet 109 6 pin 15/16 A socket outlet 110 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 111 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 112 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 113 1 or 2 Module (75mmX75mm) 114 3 Module (100mmX75mm) 115 4 Module (125mmX75mm) 116 6 Module (200mmX75mm) 117 8 Module 118 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 119 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required 120 1 run of cable 121 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 122 100 A,30KA,FPMCCB 123 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 124 6 way (4 + 18), Double door 125 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 126 Single pole 127 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 128 63 A 129 Supplying and fixing TP&N MCB,440 volts, C curve, suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning & accessories etc. as required. 130 63 A TP&N MCB 131 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. 132 For 6 way, Double door TPN MCBDB 133 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 134 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm). 135 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required. 136 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 137 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 138 Supplying and fixing TP&N MCB,440 volts, C curve, suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning & accessories etc. as required. 139 40 A 140 Supply and laying of3.5*50 Sqmm 1.1 kV grade PVC Sheathed XLPE insulated aluminium armoured cable. 141 Supply and Installation of Exhaust fan suitable for single phase, 230 volts, 50 Hz, AC supply having RPM 1100or better , 300 mm sweep, power input = 35W or less, Air delievery ≥ 700 CFM complete with motor, louvers/ shutters etc. as required in the existing window, includes dismembering of window glass, providing and fixing ACP panel (6mm thickness Aluminium composite panel) framing in place of glass, connection, testing, commissioning etc. as required. 142 Supplying, installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 143 18 watt 144 Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),CM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 145 36 watt 146 Supplying and Installation of clean room recess mounted 600X600 mm, 30-34 watt LED luminaries with lumen efficiancy of >100 lm/W, dimming option, highly specular anodized aluminum reflectors, optical antiglare system, high effiency polycarbonate diffuser with EMC/EMI compliant electronic driver having PF>0.9, THD < 10%, & minimum of 3kV surge/burst protection, complete with 50000 hrs burning for lifetime with supporting data sheet LM-79 & LM-80. Luminaries cover should be made of highly resistant, disinfectant proof laminated, safety glass/acrylic with stylish fine-grained surface. The reflectors should be of high quality, cleanable and non-deteriorating. The Recess frames should be gas tight. The white luminaries body should be made of sheet steel, perfectly powder coated, supplied ready for connection optionally for individual or series circuit with digital electronic control gear in multilamp technology. The Light fitting should be flush with the ceiling and should be removable from top or bottom. Optional pre-set color temperatures or adjust to any CCT in the Productivity Range 3000 K - 5700 K, Dimming Range 10%-100%The LED used in the luminaire shall be only Lumileds, Nichia, Cree, osram & LGIT and hanging with necessary chain etc as required. 147 Supply and Installation of 10 litre capacity Water Geysers in required locationequivalent to Jaquar model- EPM-WHT-V010* 10 liter capacity* Temperature Range:- 25-70ºC or better* Wattage:- 2KW or less* 5 star rating* suitable for single phase, 230 volts, 50 Hz, AC supply. 148 Supplying and Installation of 60 mm thick hermetically sealed single sliding door of ( 2.1 m (H) x 1.5m (W))/(2.1 m (H) x 1.8m (W)). The controller should be capable of being operated by elbow switches/ foot switches as well as touch less sensor. The track should be of Stainless steel/ Aluminum and the running surface for the top rollers should be suitably angled to reduce resistance to movement. The door material should be of HPL colour should match the interior and care should be taken to make the leaf strong and light weight.The door leaf should be hung by means of hard plastic rollers of high quality with double bearing at the top. Rollers should be provided under the stainless steel/ Aluminum track to enable smooth and noiseless movement. Opening and closing of the door should be microprocessor controlled electromechanical movement. One should be able to open and close the door effortlessly in case of failure of automatic mechanism. Door opening handle should be of SS (gloss finish), i/c high quality cylindrical lock. Door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing, Air tightness 99.99% at a pressure of 100KPa. The finished floor on either side of the door should be perfectly level (maximum permissible difference +1mm). The overall thickness of the finished door should be of 60mm. The inner part of the door should be filled with CFC free polyurethane foam. (Sealed airtight to prevent further ingress of any microbial organism). The door and controls should comply with IEE regulation. All motors used should be DC brushless motors with essential isolation from mains. All motors used should be DC brushless motors with essentíal isolation from mains. Door should be with vision window 300 mm x 300 mm with double glazed panels and hermetically sealed motorized roller blind inside. The starting time after receiving the signal shauld be adjustable between 0.5 to 20 seconds. The complete door assembly should be BIS/ European CE marked/ US FDA approved. Test certificate for hermetically sealed door frame (factory test certificate) should be enclosed with the pre dispatch documents.Hermatically Sealed HPL finish DOOR - Automatic with automation,Supply, Installation, Testing of automatic sliding hermatically OT door size of with Double sided wall frame with HPL Plank 400mm.1- Door Profiles- Aluminium Alloy, Grade 6063, Temper T6. Natural Anodized 20 μm.2-PIR. Dimensional stability at +100°C & -25°C (2%max).Density 41Kg/M3 with max deviation of 2kg/m3 as perDIN53420.3- Door Skin- HPL (4mm) both side of door4- Sealing Gasket (Sides and Top)- Replaceable Bulb and Lip design EPDM gasket.5- Sealing Gasket(Bottom)- .Replaceable Special lower sealing EPDM gasket.6-. Vision Panel- Double Glazed IG unit with 5mm tempered glass on both sides. Size = 300 mm x 300 mm x 60mm.7-Lever Handle- Solid AISI 304 Grade Stainless Steel with rubber spring system.8- Rail System- 6mm deep indentations with ‘down and in’ movement at the angle of 45⁰.9- Rollers- Special Grade Self-lubricating PA Bearings: 2X per roller.10-Wall Frame- Aluminium Alloy, Grade 6063, Temper T6 Natural Anodized 20 μm.11- Planks- HPL Planks finished with compact laminates are used to cover the door opening.12- Noise Insulation-28 dB.13- Air Permeability- Air Leakage at ± 100 Pa (pressure difference) = 0.07 m³/h.m. 1-Microprocessor Based controller. (230 Vac, 750 W (max),2- motor, IP65 protection Class, 20 Nm, 3Øx230V. (CE Marked).3- If an obstruction is present and prevents the door from closing, the intelligent automation sense with self reversal function thus eliminatingthe need for an ugly safety strip.4- Additional safety is provided by means of a photo cell fitted across the door opening.5- Variable options for the opening and closing speeds, time delay closing and part opening for pedestrian use and are easy to adjust.6- A self diagnostic coded system makes fault finding simple, reducing expensive down time.7- Magic (Hand) Switch- The spread of infection is controlled by automating the doors with touch less sensors allowing hands free operation.8- Foot switch or Elbow Switch- AISI 304 grade Stainless Steel Foot Switches with high quality inductive sensors.Control: Microprocessor-controlled with Deceleration Measurement System sliding door drive.Power supply: 230 Vac +10% / -15%. Frequency: 47-63Hz . Power Consumption -Maximum : 750 W.Drive :STG motor. Nominal Motor power:90 W, High Torque Motor -20Nm.Microprocessor controlled motor driver. Max. door weight : 350 Kg.Adjustable Speed Control level: 1-9 . Slow speed (V slow) :20(Threshold speed) - 120 mm. / sec.Starting speed (V start) :20(Threshold spped) - 220 mm. / sec. Opening speed (V open) :Threshold speed to 800 mm. / sec. Closing speed (Vclose):Threshold speed to 400 mm. / sec.Pedestrian opening (Half Opening width) :10% - 99% of the available door opening. 149 Supply ,Installation,Testing & Commissioning of factory built cabinet type unit withAl anodised thermal break frame structure injected with minimum 45+-5 mm thick PUFinsulation, GIPanelshallbepowdercoatedfrombothinnerandouterside,evaporationDxcoil expansion valve and corded remote ,Fan section with double width double inlet (DIDW backwards curved) centrifugal fan with Variable speed Fan Motor with VFD, prefilter section with EU3 / G4 class filters & EU-7 Filter(As per Approval of Engineer Incharge ) Dx coil.units shall be with a remote controller as per site requirement. Rating for the AHUs shall be as under - Motor selection (IE-3) to suit the below capacity AHU ratings. AHU shall be mounted on floor/Ceiling Mounted with vibration isolatorsUnit shall be with factory fitted inlet/outlet aluminium Aerofoil dampers. ,Temperature controller ,Door open switch ,pressure drop across filters ,Fan motor over load protector ,Suitable UV System Chamber complete with cable /wiring etc. will be part of this AHU Unit. AHUShouldhave1setofSpareFiltersapartfromCommissioningfiltersfixedinAHU. SuitableCommunication cable from indoor to outdoor is in the scope of agency .Double Skin Heater Bank Chamber comprising of SS 304 spiral strip heaters fitted with Porcelene blocks, Safety air stat & access door for heater rating , UVGI Lamp etc. As per per approved design from Engineer Incharge. AHU connection Kit with Control box (expansion valve ), Control Box,Nitrogen Testing ,Vaccuming , Green Refrigerant Top up .It should be equiped with Controler to control humidity up to 55 % (+-5%).AHU Machine should be Equipped withmotorised Fire Dampers .F.M./S.A Fan 4000 CFM /18 TR(24 HP) X 2 Numbers Coils / 6 ROW coil Full Copper , with two Stage Filter level 10 micron + 5 Micron,ESP-150 MM in WC. Design parameter- Temp.-21+-3 Degree Centigrade , Relative Humidity -55+-5% 150 Supply, Installation, Testing & Commissioning of 22 HP modular type variable refrigerant flow / Variable regrigerant Volume air cooled outdoor units suitable for cooling and heating having all hermatically sealed inverter type scroll compressor, minimum two compressor for above 14 HP modules, microprocessor based controller,top discharge type condensing units, with R410 A refrigerant, Vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 degree Celcius ambient temperature without tripping. The unit shall be suitable to work on 400+/-10%, 3phase , 50 Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required with suitable communication cable. The COP at AHRI Conditions shall not be less than 3.1 and IEER not less than 6.5. 151 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 152 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 153 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 154 Supplying and installing 225 mm width X 50 mm depth X 1.6 mm thickness size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 155 Supply, installation, balancing and commissioning of Site fabricated Aluminium 0.80 mm rectangular/Circularducting as requiredwith supports as per IS 655-2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following gauges (Galvanizing shall be with zinc nominal 120 gm/sqmtr) includes cutting/ dismanteling of wall (if required) and make good the same.Note: Fabrication and jointing of duct shall be as per IS standard and hanging shall be as per SMACNA. 156 Thickness 0.80 mm sheet 157 Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. 158 Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. 159 Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. 160 Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. 161 Fire Damper 162 Actuator 163 Supply and fixing of acoustic lining of AHU wall and ceiling with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to wall and ceiling with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. 164 Supplying and fixing of 19 mm thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 165 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge for Drainage. 166 32 mm nominal dia. 167 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit,fitting as required. 168 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 169 Supply ,Fixing and erection of Duct rexin Fire Retardent Canvass Connections with Vibration & Isolation Pad complete as required . 170 Supplying and fixing of MS of (40X40X5)mm stand for condensing (Outdoor) with epoxy painting, unit Size - 1040 mm(L)*440mm(W)*300(H)} . 171 8 SWG (Copper ) Earthing Cable Supply & Fixing complete as required . 172 Supply and fixing of 10 mm Open cellacoustic insulation of supply air duct and plenum with fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per direction of Engineer Incharge AIIMS Raipur. 173 Supplying, fixing, testing and commissioning of Hepa Filter of required Specification withincluding making arrangement for fixing complete as required and as per direction of Engineer-in-charge.Class-14,Efficiency -99.97 174 Supplying, fixing, testing and commissioning of 1 Tile Membrane Surgeon Control Panel of following Specification including making arrangement for fixing with necessary acessaries ,Cable etc. complete as required and as per direction of Engineer-in-charge. 175 Supplying, fixing, testing and commissioningofmotorised damper as required Specification withnecessaryarrangementas per direction of Engineer-in-charge. 176 Supply and fixing ofinsulation work with 6 mm nitrile rubber on existing CPVC drain pipe(32 MM) properly as required. 177 Supply, Installation and Testing of G I Sheet with Galvanized Coating cable tray cover for 225 mm powder coating M.S. cable trays it is highly durable and robust , corrosion and can sustain high load andincluding bolts & nutsall accessories as per specifications etc. as required. 178 Supplying, installation, testing and commissioning of M.V/LT. cubical type totally enclosed dust and vermin proof Floor/Wall mounted Sub Main Distribution Boards suitable for use on 430 V 3 phase 4 wire 50 Hz AC supply, having compartmentalized construction for different incoming/outgoing MCCBs from Approved Make, and separate bus bar & cable alleys , fabricated from min 1.6mm thick CRCA sheet steel of uniform width complete with copper bus bars , MV/LT danger notice plate, Digital type ammeter with Ammeter selector switch , voltmeter with Voltmeter selector switch , LED indicating lamps, cast resin CTs , Confirms to IEC-61439-2, IP-43, Interconnection with suitable capacity copper strips / rods, connection of incoming and outgoing cables with thimbles , smoke/Siemens grey colour stove enamelled painted and having following incoming and outgoing switchgears, 2 earth bolt, removable cable gland plate with spare suitable hole, wall/floor mounted, lockable using hollow standard LT Panel lock key complete as per site required or as approved by Engineer In-charge. A. INCOMER 01 nos. 250amps 35kA TPNL MCCB from Approved Make Thermo-magnetic release type with rotary handle. 01 nos. Digital type single function volt meter to show 0-500V voltage with phase selector switch01 nos. Digital type single function ameter to show amperage with phase selector switch 03 Nos Energy Meter 03 Nos CTs 125/5 ratio 03 LED Indication Light with toggle switches B. OUTGOING 08nos. 40A TPNL MCCB (25 KA) Thermo-magnetic release type. 179 Dismentlingwork of Existing installed duct, FCU, HVAC Pipelines, Starter Panelincluding Welding, Cutting as required as per direction of Engineer Incharge AIIMS Raipur. 180 Supplying, installation, testing & commissioning of smokedetector with builtin LED and mounting base complete with all connections etc. as required. 181 Supplying,installation,testing&commissioningofmanualcallboxesofMS constructionin surface/recesswithstainlesssteelchain&hammerassembly complete with glass and push button etc. as required. 182 Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. 183 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 184 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered along with battery arrangement for power backup complete with all connections, interconnections as required. 185 4 Zone 186 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 187 Supply and fixing of 4 kg clean agent (HCFC) portable fire extinguisher having pressure guage indicator and arrangement for wall hangingand with warranty for 5 years on complete product. 188 Providing and fixing you are here sign board near entrance and fire reflective sign board, reflective stickers signage for indication at fire doors, fire extinguisher, fire exit with suitable size as per requirement and as per instruction from Engineer In-charge.
Contract Date: Apr 16, 2026 Contract Value : 1.09 Crore
Government Departments No of Bidders 4
Chhattisgarh View Result →
24.
Defence #9982059 AOC
Bids Are Invited For 1 VALVE 4 3 WAY 2 MOTOR PROTECTOR 3 ATTACHMENT ADAPTOR 4 SELECTOR SWITCH KEY 5 PILOT LAMP 6 MCB 2 POLE C CURVE 10 AMP 7 LOCK NUT 8 LOCK NUT 9 LOCK NUT 10 O RING KIT 11 GLYD RING 12 BLEED VALVES 13 FLEXIBLE HOSE 14 CO2 CYLINDER INTERCONNECTION PILOT HOSES 15 TERMINAL BLOCK 283 901 16 TERMINAL BLOCK 281 901 17 TERMINAL BLOCK 280 519 18 TERMINAL BLOCK 2002 3201 19 MULTIPIN CONNECTOR MS3102R22 14S 20 MULTIPIN CONNECTOR MS3106F22 14P 21 TEFLON TAPE 22 VENT VALVE 23 INSULATION TAPE 24 CO2 CYLINDER HEAD VALVES 25 MAIN CONTROL PANEL 26 MIMIC PANEL 27 JUNCTION BOX TYPE 1 28 JUNCTION BOX TYPE 2 29 POD DCV 25MM 30 MANNUAL LEVER BOX ASSEMBLY 31 ZONAL VALVE CABINET 32 PUSH BUTTON EPBS 33 PILOT RELEASE CABINET 34 TIME DELAY UNIT 35 SS 304 TUBING 36 CAPACITY CONTROL SOLENOID VALVES TAG NO SV1 & SV2 37 POTENTIOMETER SHAFT 38 FOUR POINT CONTACT BALL BEARING 39 ORIFICE PLUG 40 MOTOR STARTER 41 PISTON SET 42 SHAFT SEAL END BEARING 43 THRUST BEARING KIT 44 SEAL LIP 45 SHUT OFF VALVE 46 SHUT OFF VALVE 47 SCHRADER CONNECTION 48 GASKET FOR CAPACITOR COVERS 49 GLAND SET 50 SPRING COMPRESSION 51 PIN SPRING 52 PIN SPRING 53 VALVE CHECK 54 SPRING COMPRESSION 55 PLATE CLOSURE 56 SPACER INBOARD BEARING 57 GEAR SET 64 33 XJF151N 58 SHIM 59 RING RETAINING 60 BEARING CYLINDRICAL ROLLER 61 BEARING CYLINDRICAL ROLLER 62 BEARING CYLINDRICAL ROLLER 63 PLUG ECONOMIZER 64 LOCKNUT 65 LOCKNUT 66 PLUG 1 8 27 NPTF w 062 ORIFICE 67 BEARING ANGULARY CONTACT BALL 68 BUSHING INLET 69 SEAL GAS 70 RETAINER CHECK VALVE 71 KIT FOR SHAFT PACKING 72 TEMP CONVERTER 73 MCB 2 POLE C CURVE 6 AMP 74 MCB 2 POLE C CURVE 02 AMP 75 MCB 3 POLE C CURVE 02 AMP 76 MCB 2 POLE C CURVE 04 AMP 77 SIEMATIC HMI KP 400 COMFORT PANEL 78 OIL FILTER CARTRIDGE 79 FLAT GASKET 80 O RING 81 O RING 82 O RING 83 O RING 84 O RING 85 O RING 86 O RING 2 261 87 O RING 88 O RING 89 RING SEALING 906 90 PURGING VALVE SHRADER VALVE 91 FLEXIBLE METAL HOSE 92 SHUT OFF VALVE 93 SHUTOFF VALVE 94 PURGING VALVE 95 CHARGING VALVE 96 SHOCK DAMPER 97 CONDENSERS OF CHILLED UNITS AC 98 FLEX METAL HOSE 1 07 99 LEVEL SWITCH KLIMAF ON RECEIVER 100 OIL HEATER 101 THERM INJECTION VALVE 102 OIL TEMPERATURE RELAY 103 OIL TEMPERATURE RELAY 104 DISCHARGE TEMPERATURE SWITCH 017 5135 105 TX2 R22 5 8 X12MM 106 GAUGE OIL PRESSURE 107 FEELER POCKED 108 MOTOR PROTECTION 0 4 0 63A 109 MOTOR PROTECTOR 110 STOP VALVE 111 PLC BASED CONTROL PANEL 112 IMPELLER 113 SWITCH 114 AIR CONTACTOR 115 RELAY 116 FREEZE PROTECTION THERMOSTAT 117 FUSE SWITCH 118 FUSE SWITCH 119 FUSE SWITCH 120 CONVERTER Total Quantity : 3245
Contract Date: Ref. Documents Contract Value : 10.70 Crore
Government Departments No of Bidders 1
Maharashtra View Result →
25.
Defence #9835139 AOC
Tender For Completion Of Incomplete Work For Provn Of Otm Accommodation (Ph-I Of Two Phs) At Panagarh Mil Stn Under Ge (P) Panagarh.; 1 Sch A Part -I (Building Works)Note:- This Sch is notpre-priced by MES and the pre-priced rate indicatedas Rs 0.00 under Col 5 signifies this fact only. 2 Completion of incomplete Building for signal unit with all fitting and fixtures etc. Complete all as specified and as shown on complete drawings. 3 Completion of incompleteBuilding for office accn/ Adm block with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 4 Completion of incomplete Building for JCO Mess and single living JCO accn with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 5 Completion of incomplete Buildingfor single living ORs accn / Dinning and cook house with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 6 Completion of incomplete Building for Storage Accn (Armouries)& Guard House alongwith hardstanding with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 7 Completion of incomplete Building for Store Room (General Authorisation) with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 8 Completion of incomplete ramp with all fitting and fixtures etc. Complete all as specified and as shown on drawings 9 Completion of incomplete Building for sentry post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 10 Completion of incomplete Building for Ironing Room with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 11 Completion of incomplete Building for Meter & Switch House with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 12 Completion of incomplete Pump House/ UG water tank with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 13 Completion of incomplete RCC OHT Tankwith 18mtr staging with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 14 Completion of incomplete Incinerator with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 15 Completion of incompleteFlag mast with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 16 Completion of incomplete Alarm post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 17 Completion of incompleteFire point with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 18 Completion of incomplete Refuse bin with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 19 Completion of incompleteDhobi ghat with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 20 Lumpsum price worked out by the tenderer/ bidder for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK AND EXCAVATIONas listed in Schedule ‘A’ Part-II on Serial Page No. __ 21 Lumpsum price worked out by the tenderer/ bidder for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III on Serial Page No. __ 22 Lumpsum price worked out by the tenderer/ bidder for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV on Serial Page No. __ 23 Lumpsum price worked out by the tenderer/ bidder for ROAD/ PATH/ CULVERT as listed in Schedule ‘A’ Part-V on Serial Page No. __ 24 Lumpsum price worked out by the tenderer/ bidder for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI on Serial Page No. __ 25 Lumpsum price worked out by the tenderer/ bidder for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII on Serial Page No. ___ 26 Lumpsum price worked out by the tenderer/ bidder for SECURITY FENCING AND GATE as listed in Schedule ‘A’ Part-VIII on Serial Page No. ___ 27 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX on Serial Page No. ___ 28 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL ELECTRIC SUPPLYas listed in Schedule ‘A’ Part-X on Serial Page No. ___ 29 Lumpsum price worked out by the tenderer/ bidder for LIGHTENING PROTECTIONas listed in Schedule ‘A’ Part-XI on Serial Page No. ___ 30 Lumpsum price worked out by the tenderer/ bidder for RAIN WATER HARVESTING / RECHARGE PIT as listed in Schedule ‘A’ Part-XII on Serial Page No. ___ 31 Schedule ‘A’ Part-XIII (MISCELLANEOUS ITEMS)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 signifies this fact only. 32 M & L for mixing of Fly ash, Clinker & stone dust in proportion of 1:3:6 ( i .e10 %Fly ash, 30% Clinker and 60% Stone dust) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete as directed .Note:Break down details of this Items is shown in Annexure ‘B’ in Schedule ‘A’ Notes. 33 (INTERNALELECTRIFICATION)Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box screws complete including PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point / call bell point controlled by one, one way switch complete all as specified and as directed. 34 All as per Ser Item No 13.02 here-in-above but for one ceiling/ exhaust fan point controlled by one switch complete all as specified and directed. 35 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one 5/6 Amps socket outlet points controlled by one, one way switch on independent board complete all as specified and as directed. 36 All as per item No. 13.04 above but one 5/6amps socket outlet point on the same board with other switches complete all as specified and as directed. 37 All as per item No. 13.02 above but for one Point wiring controlled by two nos two switch complete all as specified and as directed. 38 Material and labour for point wiring with 4sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 4 sqmm green colour as earth continuty conductor connected to common earth dolly for one15/16 Amps socket outlet points controlled by one, one way switch modular type on independent board complete all as specified and as directed. 39 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed stove enameled steel conduit of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point controlled by one, one way flame proof rotary type switch complete all as specified and as directed. 40 Supply and fixing switch flame proof rotary type with terminal box in LM6, 16 amps single pole 230 volts complete all as specified and as directed. 41 M & L for modular metal flush box 12 Module complete all as specified and directed. 42 M & L for modular white cover plate with frame, 12 module complete all as specifed and directed. 43 S & F for LED lamp 7 watt (retrofit) complete all as specifed and directed. 44 S & F LED type conical shape wall metal body with 1 no 7 Watt retrofit LED Lamp minimum lumen 700, complete all as specifed and directed. 45 S & F LED type table lamp / bed side light ( 3000k) Metal body 2 Watt minimum 50 lumen complete all as specifed and directed. 46 S & F telephone Socket (RJ-11) modular type complete all as specifed and directed. 47 S & F TV Socket modular type complete all as specifed and directed. 48 Supplying and fixing ceiling fan five star rated withBrush Less direct current (BLDC) 1200 mm sweep (without remote ) , 28 W complete withblades,down rod and accessories,230v,Min delivery 210 CFM with service value 6.00 BEE complete all as specified and as directed. 49 All as per Ser Item No 13.17 here-in-above but for 1400mm sweep, Minium air delivery 245 CFM with service value 6.00 BEE, five star rating with brushless direct current motor (BLDC) complete all as specified and directed. 50 Supplying and fixing exhaust fan made of sturdy Engineering plastic complete with lovers shutters, AC single phase, 230 V, 50 HZ , 1200 RPM, Copper winding, 250mm Sweep complete all as specified and directed. 51 Supplying and fixing exhaust fan noiseless square type metal body case , 450mm sweep heavy duty single phase (1400 RPM) ISI marked with blades flush mounting withlouvers, AC single phase 230/240 volts, 50 Hz including necessary fixing accessories and make good of surfaces complete all as specified and as directed. 52 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 6 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 53 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 8 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 54 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 4 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 55 Supplying and fixing MCCB 125 Amps, capacity 25kA, 4 pole, 415 volts (Adjustable thermal type & fixed magnetic setting) complete all as specified and as directed. 56 Supplying and fixing sheet metal enclouser for DBS Single pole and neutral 6 way double door with 200 Amps rated bus bar 240 Volt complete all as specified and as directed. 57 Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm diawith all fittings and conduit accessories concealed type including one run 4 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note:-(i) Two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 58 Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm dia with all fittings and conduit accessories concealed type including one runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 59 Material and labour for sub main wiring with four runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less tha 25 mm dia with all fittings and conduit accessories concealed type including two runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) Four runs of cable with two runs earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 60 Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including complete all as specified and directed. {NOTE:- (i) Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item..} 61 (ROAD/PATH)M & L 225 mm thick (compacted thickness)wet mix macadam( WMM), with curshed stone aggregate and stone dust (as per design mix)of specifiedgrading, spread using mechanical paver as specified, watered, rolled & consolidated as specified to required gradient and camber complate all as specified & directed. 62 M&L for laying polythene paper black 150 micron with laps complate all as specified & directed. (Area for polythene paper without considering lap shall be measured and paid) 63 M&L and laying 150 mm thick (compacted thickness) wet mix macadam (WMM) with crushed stone aggragate of specified grading,spread using mechanical paver as specified, watered, rolled and consolidated as per required greadeant and camber complate all as specified & directed. 64 M&L for 100 m thick dry lean concrete (DLC) over a prepared subgrade with coarse and fine aggregate conforming to IS : 383, Size of aggregate not exc 40 mm (Grading and other parameters as per table 600 - 1 of MORTH, IRC SPR : 49 Specification) complate all as specified & directed. 65 M&L for cleaning and preparing the road surface and making good for road marking applying reflective thermoplastic white road marking paint (HOT APPLICATION) comforming to BIS 3262 laid down through modern propelled road marking machine in a layer of CRYSTALEX and use of all ingredients such as binder, glass, beads, titanium dioxide, calcium carbonate, interfiller thermoplastic required for glass beads per square meter by incorporating the white glass beads for reflectivity in 100mm width complete all as specified and as directed.Make of Thermoplastic Road marking paint/Retro-Reflective paint - M/s Asian Apcomark, M/s STP or M/s Shalimar Paints Ltd or M/s Berger Paints Ltd, M/s Jhonson & Nicholson Paints Ltd or M/s Jotun India Pvt Ltd. 66 (SEWAGE DISPOSAL)M&Lfor constrution of RCC Septic tankcoventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users Complete all as shown on drawing and as directed. 67 M&L for constrution Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 4.5 M effective depth Complete all as shown on drawing and as directed. 68 (EXTERNAL WATER SUPPLY) Design, supply, install, testing and commissioning Iron removal pressure feed type filtration plant 10000 GPH to with stand pressure 10 Kg/Sq cm with catalytic and filter media (as required size and grade / mesh to obtain potable water recommended parameters as per WHO) including MS frontal pipe (duly welded), Cocks, valves, (inlet outlet, back wash, rinse, bypass complete as per manufacturers instruction). Provision of main hole Hand hole strainer including air vent system, coagulant feeder with accessories, oxidation chamber with media, (MnO2) with all accessories suitable capacity with all fitting fixture, pressure gauges, RCC/PCC foundation as per OEM recommendation. Drainage system and connected to rising and delivery system including painting and writing complete. The technical details of Oxidation chamber and Multigrade filter are as given below:- 69 A) Oxidation Chamber- (i)Feed Flow - 40 M³/Hr. (ii) Operating pressure - 3.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm. (iv) MOC of vessel - MS. (v) Frontal Pipeline Size - 150/100mm. (vi) Media type - Manganese-di-oxide. (vii) Thickness in mm (shell and dish-ends) - 6 mm. (viii)Media Quantity - 600 Kg. (B) Multigrade Filter- (i) Flow rate - 40 M³/Hr. (ii) Operating pressure - 3.5-5.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm². (iv) Continuous duty cycle - 48 Hrs. (v) Backwash - 20 Min. (vi) Rinsing - 10 Min. (C) Filtering Media Details- (i) Media Type - Mixed sand. (ii)Depth of sand - 2800 Kg. (iii) Depth of Gravels support - 2000 Kg. (iv) Guaranteed life of filtering media - One year.(D) Vessels Details- (i) Type Cylindrical - Vertical. (ii)Dimension in mm (DIA X HOS) - 1600 X 2300 mm. (iii) Free board for back wash - 50%. (iv)Materials - MS. (v) Thickness in mm (shell and dish-ends) - 8-10mm. {Note:-- Rate deemed to be included with the followings:-(a)Raw water and treated water tested report of all parameter from National Test House Salt Lake. (b)Training to DEL Staff with required material and maintaining log book and other register as directed. (c) Electronic flow meter-01 including necessary wiring complete. (d)Butter fly and gate valves as required.(e) 2 Nos air compressor of capacity 210 CFM with 3 Phase Motor, Starter, air pipe connection including electrical connection complete. 70 Supply, install, lowering, testing & commissioning of submersible pump set 8 stage, suitable forminimum head 40 Mtr with 635 lpm dischage with electric driven motor of capacity 15 hp, 415 V AC, TP with operational efficeiency performance and durability wide voltage range 350-440 Volts, super finished water lubricated bush bearing, with less speed drop motors with reflon bearing and sand guard complete all as specified and directed by Engr-in-charge. 71 Trail drilling of bore of size 250 mm dia upto 120 mtr depthby direct rotary/ DTHmechanical system for injection wellin any kind of soil strata including hard stone/boulders and submitting the strata detail both graphically recorded as well as strata results including testing of yield , complete all as specified and as directed. 72 Reaming of bore well from 250 mm dia to 525 mm dia hole in three steps from 250 mm to 350 mm, 350 mm to 450 mm and 450 mm to 525 mm dia bore siutable for lowering ERW Mild steel casing pipes and gravel packing for the required length (i.e 50 mtr depth) below the ground level , complete all as specified and as directed. 73 All as per item no 13.41 here-in-before but exceeding 50 mtr and upto 170 mtr depth, complete all as specified and as directed. 74 Supply, assembling, lowering and fixing in position 250 mm nominal (10) bore ERW MS housing pipe, ISI marked,of 8 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth upto 40 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding , complete all as specified and as directed. 75 Supply, assembling, lowering and fixing in position 200 mm nominal (8) bore ERW MS housing pipe, ISI marked,of minimum 8.0 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth exceeding 40 mtr and upto 120 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding, complete all as specified and as directed. 76 Supply, assembling, lowering and fixing in position low carbon galvanized (LCG) steel strainer pipe 200 mm nominalbore of wall thickness 7.00 mm cagetype wire wound screen ‘V’ shaped profile in suitable length having slots of size 1.6 mm width including necessary end coupling,electric Arc welding as required and including special sockets for connecting to MS pipe, complete all as specified and as directed. 77 Supply and fixing mild steel reducer suitable for (250 x 200 mm ) bore casing pipe, 10 mm thick, fitted to casing pipe as per IS 2800 by means ofelectric Arc welding ,complete all as specified and as directed. 78 M&L for carrying out electro logging test upto complete drilling depth of tube well for fixing water strata and submitting of Report including its interpretation by a qualified Hydrologist/ground water expert , complete all as specified and as directed. 79 S&Fmild steel bail plug assembly suitable for 200 mm bore casing pipe internal threaded with strong iron hook, screwed and welded to casing pipe as per IS 2800 , complete all as specified and as directed. 80 Supply, filling and packing washed pea gravels of size 2 mm to 4.6 mm all around casing pipe and slotted pipe, complete all as specified andas directed 81 S&F mild steel housing clamps 1200 mm long 100 mm wide , made out of 20 mm thick MS plate made to shape for 250 mm bore casing pipe with necessary bolts, nuts and washers at ground level, complete all as specified and as directed. 82 Developing of tube well by means of air compressor, for number of hours, until sand free clear potable water is obtained including testing by using diesel engine driven turbine pump to get maximum yield and discharge including supply of yield test result , complete all as specified and as directed. (Note : The rates of DHPP is inclusive in the quoted rate) 83 S & F well cap made out of 5 mm thick MS Plate with provn of suitable holes for passing two runs of flat 3 core PVC insulated sumersible cable motor and one run of SWR, 100 MM dia column pipe and suitable for fixing 250 mm nominal bore ERW heavy duty MS of 8.0 Mm Wall thickness casing pipe complete all as specified andas directed. 84 S&F pressuregauge with isolation cock suitable for a working pressure of 7 Kg/cm² (Liquid based High Intensity), complete all as specified and as directed. 85 Supply and laying flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 10 Sqmm 3 core including jointing material and connection work , complete all as specified and as directed. 86 S&F round strand steel wire rope dia 12 mm and connected clamp nut bolts fixed ,complete all as per directed. 87 Supply , lowering and fixing MS column pipe 100 mm bore, medium grade, confirming to IS, 3 meter long pipe both end flanged, threading, welding and drilling of holes, cutting of ducts of size 10 mm x 20 mm 2 No. in each flange for fixing submersible cable, including rubber gasket of suitable size, nuts, bolts, washer etc including painted internally and externally with two coat of non corrosive non toxic bituminous paint including making all type of connections as required, complete all as specified and as directed. 88 Supply , install, testing and commissioning of cubical housing cabinet type weather proof powder coated LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proofof CPRI approved,openablefrom both front and rear side made of2 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- 89 (i) Aluminium Bus bar 160 Amps -25 KA breaking capacity(ii) Incoming MCCB, 4 pole, 100 Amps, 415 Volt AC, 25 KA rupturing capacityQty 1 No(iii) Outgoing MCCB, 3 pole, 32 Amps, 415 Volt AC, 10KA rupturing capacityQty 4 Nos(03 For submersible pump and 01 standby)(iv) Outgoing MCB 4 Pole 32 Amps, 10 KA, 240 Volts - 01 Nos(v) Star delta motor starter suitable for 15 HP motor pump - 03 Nos(vi) LED indicating lamps - 03 Nos(vii) Digital Volt meter (Size - 96 x 96mm) 0-500 Volts with selector switch - 01 No(viii) Digital Ammeter (Size96x96mm) With selector switch including CT ( 100/5Amp) with all connection- 01 No(xiv) Matering and accessories complete all as directed by Engr-in-Charge. 90 Supply, installation, commissioning and testing of 200mmsluice valveof cast iron body flangedconforming to IS-14816, PN-1.6 Non rising type spindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 91 Supply, installation, commissioning and testing of 150mmsluice valveof cast iron body flanged conforming to IS-14816, PN-1.6 Non rising typespindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 92 Material and labour for Construction of brick masonry valve pit of internal dimension 90 cm x 90 cm x 90 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 93 Material and labour for Construction of brick masonry valve pit of internal dimension 60 cm x 60 cm x 60 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 94 Supply, install, testing & commissioning of Centrifugal pump suitable for minimum, Discharge 635 LPM at 30 Mtr head with cast iron casing, bronze impeller, SS Shaft, electric driven motor of 10 HP, 415 V, TP suitable for under ground sump and install complete including PCC foundation as per manufacture instruction complete all as specified and directed. 95 Supply, install, connecting, testing & commissioning of high pressure single head adjustable chemical dozing system of the folowing specification : (a) Adjustable high pressure 100 PSIG Power input 230 V, 50 HZ, Max flow rate 02 US GPD to 40 US GPD with mandatory assecceries like lead tubing connecting ferrules, check valves, 170 ltr FRP solutin preparetion tank with lid, port hole, inlet/outlet/drain connection, level guage ete and fitted with 900 RPM motor PVC agitator combined with 100 ltr dosing tank lid port hole inlet/outlet/drain connection, level guage etc either fitted with 900 RPM moter and PVC agitator complete all as speficified and directed.Make : Any make of E-in-C approved or ISI Marked of any make as approved by Accepting Officer. 96 Supply and laying DI Pipe 200mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 97 Supply and laying DI Pipe 150mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 98 M&L DI Fittings bends (any type radius and angle) tapers any type, (straigth, bend, increasing, decreasing or double socket etc) Tee pieces single branch Y junctions double branch, cross (all sockets or socket and spigout ) collars, caps and plugs upto 300 mm bore complete all as specified and directored. 99 (EXTERNAL ELECTRIC SUPPLY)suply , installation and commissioning of compact secondary substation (CSS) 315KVA comprising to following parameters:-(a) Housing to made with conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to high voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lighrening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h) Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside fo the CSS.(l) Necessary HT and LT cable / earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 100 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs adn PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet enclosure with automatic sagety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch. 101 (vii)Shunt trip coil- 230 V, AC(viii) Safety interlock locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, space heater with thermostat, fuse adn ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle(xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 315 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 25.% on HT side all technical specification comprising to IS 11171 update version part with all necessary satndard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 315 KVA (ii)Primary Voltage - 11 KV AC(iii) Secondary Voltage - 433 Volts . 102 (iv)Neutral earthing should be solidly earth system (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs). q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 103 Suply , installation and commissioning of Compact Secondary Substation (CSS) 250 KVA comprising to following parameters :-(a) Housing to bemade with Conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to High voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lightening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h)Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside of the CSS.(l) Necessary HT and LT cable / Earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 104 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs and PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet steel enclosure with automatic safety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch.(vii)Shunt trip coil- 230 V, AC(viii) Safety Interlock Locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, Space heater with Thermostat, Fuse and ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle. 105 (xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 250 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 2.5% on HT side all technical specification comprising to IS 11171 update version part with all necessary standard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 250 KVA (ii)Primary Voltage - 11 KV AC 106 (iii) Secondary Voltage - 433 Volts (iv)Neutral earthing should be solidly earth system. (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance.(p)LT Panel for 250 KVA Transformer made with 2 mm CRCA sheet with necessary angle iron frame and vermin proof font side openable double door with necessary locing arrangement opening for bus bar / cable entry opening for natural air ventilation / cooling necesary Ammeter, Voltmeter, Selector switch, CTs , suitable size bus bar, paints and primer with Air Circuit Breaker (ACB) as incomer 630A, 50 KA, 415 V , AC, 50 Hz, 4 Pole with neccesary setting and microprocessor control draw out type bus bars, as outgoing MCCB 200 Amps, 35 KA - 02 Nos, MCCB 160 Amps, 35 KA - 02 Nos & 32 A MCB 4 Pole - 04 Nos. (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs).(q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 107 Supply and fixing LED street light fittings on ploes capacity 45 Watts, high pressure die cast aluminum housing IP 66 rating front cover made of toughened clear glass, suitable for pole mounting wih bracket arm 40mm dia, Gl light grade pipe upto 1.4 m long, bend to required shape, clamp 40mmx6mm or required length including nuts & bolts fixed on steel poles complete all as specified.Model No : ENDURASUNDOWNSL45WLED765PASYBOTG of make : Havells or equivalent make as per Appendix D. 108 Supply & Fixing junction box with 3 Phase terminals and size of box 130mm x 180mm x 77mm or nearest higher size made of polycarbonate with IP 66/67 degree of protection, dust proof, water tight,shock proof, fire retardant,with internally embedded gasket fitted with heat treated bakelite for terminals block and PVC Glands for cable entry complete all as directed 109 M&L Three core 1.5sqmm(nominal area)service wire PVC insulated copper conductor FRLS, multi stranded, unsheathed 1100 volts grade IS-694 marked andfrom junction box to street light fitting through steel pole withPVC conduit & necessary clamps, bolts & nut etc required for fixing complete all as specified and directed. 110 Supply , install, testing and commissioning of cubical housing cabinet type conforming toCPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowings :-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -200 Amps , cable entry (incomming and outgoing ) form bottom with cable gland Incomming : 125 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No (Incoming from CSS)Outgoing -(a) MCCB 4 pole 100 Amps 25 kA - 02 Nos (for signal unit and 1 standby)(b) MCCB 4 pole 16 Amps 25 kA - 2 Nos (For OFFR Living ,meter or switch house and and 01 No for street lights)(c)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor(d) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) LED indicating lamps -03 Nos 111 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -400 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 250 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 200 Amps 35 kA - 01 Nos (Adm buidling)(b) MCCB TPN 16 Amprs 25 KA-02 Nos (Guard house and standby)(c) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(d) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No(e) LED indicating lamps -03 Nos. 112 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approvedLT panel board Outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -600 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 315 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 125 Amps 35 kA - 03 Nos(02 Nos for OR Accomodation and 01 Nos standby)(b) MCCB 4 pole 63 Amps 25 kA - 01 Nos(JCO Accomodation and JCO Club) (c) MCCB 4 Pole 25 Amprs 25 KA - 01 Nos (Drying and ironing room)(d) MCCB TPN 16 Amprs 25 KA - 02 Nos (Street lights and one standby)(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos (g) LED indicating lamps -03 Nos (h)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor 113 Supply, install, testing and commissioning of Automatic Power Factor Correction (APFC) panel board of aggregate capacity 15 KVAR suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, outdoor type, cubicle, floor mounted, free standing dust and vermin proof, air ventilation made out of 3 mm thick CRCA sheet duly powder coated, Manufactured shall be CPRI norms and as approved by GE, factory made.Panel board shall have front and rear opening with hinged type doors and rubber gasket, handles, industrial type locking arrangement, cable alleys, switch gear compartment, bottom cable, entry holes for incoming and outgoing cables, earthing terminals, danger notice plate, Aluminum bus bar duly covered with heat shrink sleeves of colour coded duly fixed on DMC / SMC insulators housed in a separate bus bar chamber including control wiring with PVC insulated, flexible, multistranded copper conductor cables of adequate size and of adequate length for connecting of capacitors, contactors etc duly ferruled crimped with suitable lugs / thimbles and including connecting of incoming and outgoing cables. Panel board shall be mounted on and including MS angle iron frame of suitable size duly painted and PCC1:2:4 type B1 for foundation / Platform to suit the site requirement complete all as specifiedand directed and comprising of following:-(i) APFC relay microprocessor based digital display type of 9 stages suitable for operation of PF upto unity – 01 No. 114 (ii) MCCB 320 Amps, 4 pole, 50KA, 415V, 50HZ – 01 No for incoming.(iii) MCCB 80 Amps, 4 pole, 25KA, 415V – 03 No’s for capacitor outgoing.(iv)MCCB 40 Amps, 4 pole, 25KA, 415V – 01 No for capacitor outgoing.(v)MCCB 16 Amps, 4 pole, 25KA, 415V – 05 Nos for capacitor outgoing(vi) MCB SP 0.5 to 5 AMPS, ‘C’ Curve, 240V-09 Nos as per circuit control.(vii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -05 Nos.(viii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -02 Nos.(ix) Capacitor Bank 1 KVAR, 3 phase, 440V MPP type including suitable rating contractor -01 Nos. 115 (x) LED indication lamps RYB – 01set.(xi) Auto / manual selector switch -01No.(xii) Push button and indication lamp for each capacitor bank -01 set.(xii) Digital voltameter with selector switch -01set.(xiv) Digital ammeter with selector switch & CT’s -01.(xv) Aluminium bus bar TPN 480 Amps rating -01 set.Note: The contractor should be factory inspection and drawings approval by the GE / Engineer-in-Charge before procurement after commissioning of APFC panel the power factor (PF) to achieve 0.95 to 0.99 mandatory at any load condition automatically. 116 Supply and fix solar street light smart integrated solar system all in one with MPPT (Maximum Power Point Tracking) charge controller ,Tilable LED Panel,Adjustable AIO mounting angle ,mono crystalline solar panel ,PIR motion sensor, and 6m tubular pole with 30 wattLED light at a rate 100 lm/w, 60wp, 75 AH (Lithium ferrous phosphate battery luminaries must have a life of greater than 50,000 hours and have IP 66 rating, the modules are to bedesigned to with stand corrosive atmosphere and heavy wind loads. the modules are to be certified for standers IEC 61215, IEC 61730 (Safely class I & II) complete all as specified and directed. 117 Supply and fix LED post top lantern decorative typeo fttings for 360 degreee indirect light on pillars of capacity 40 watts high pressure die cast aluminium housing IP 65 rating, suitable fr mounting 40 dia GIlight grade pipe upto 0.5 m long or required length including nuts and bolts and fixed complete all as specified and directed.Model No : RUBYPT40WLED757PSYMTOPC OF MAKE : Havels or equivalentmake as per Appendix D 118 M&L fpr boring holes horizontally under road without damaging the surface of road (minimum 1 mtr below the road surface/ footpath with the help of GI tubing not exceeding 100mm dia bore for passing of UG cable complete all as specified and directed. 119 (REFGIGERATION & WATER COOLER) Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 308 - 315 ltrs capacity, conforming to IS 15750 (2006) for frost free, with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 120 Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 192 - 210 ltrs capacity, conforming to IS 1476 for direct cool with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 121 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 320 ltrs, BEE 5 star rating complete all as specified and directed. 122 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 400 ltrs, BEE 5 star rating complete all as specified and directed. 123 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 80 Ltr and nominal cooling capacityof 40 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 124 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 120 ltr and nominal cooling capacityof 60 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 125 S & F Voltage stablizer of capacity 2 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 126 S & F Voltage stablizer of capacity 1 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 127 (DG SET) M&L Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected tousing galvanised iron strip 32×6mm as earthing lead earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated by Engr-in-charge including testing on completion. 128 Supply and installation testing and commissioning silent Diesel Enginegenerating set 415 volts 40 KVA3 phase 0.8 power factor, 50 Hz, 1500RPM self exicited self regulated brushlessAC generator installed including AMF panel,suitable for ambient condition at Panagarh and confirming to condition under ISO 3046, IS:10001/ 10002,BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration and including the following accessories :- (A) Alternator:- Synchrounous alternator rated at 40 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p.f (lag) suitable for 50 Hz, three phase, 4 wire system.The alternator shall be brushless, single bearing, self excited/ self regulated with an AVR. The alternator will be suitable for climate and shall generally confirm to IS: 4722 :2001. The salient features of the alternators are :- (a) +-1% voltage regulation (max) in static conditions.(b) IP:23 protections with class H insulation.(c) Permanent lubricating bearing. 129 (B) Diesel Engine:- Adquate capacity of diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500RPM, as per relevant IS/BS complete with standard accessories. (C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent (to comply GRIHA and other agencies norms) canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimentional accuracy of holes within 0.1 mm.Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility (D) AMF panel : Automatic Mains Failure (AMF) panel made of CRCA sheet of 2 MM thick including necessary arrangement to install, testing and commissioning & connecting ot load cable to up ot changeover switch, suitable capacity of 4 pole MCCB complete all as per OEM recommendation.(E) Civil Works :- All civil works including PCC platform and related foundations incl for panel and equipments incl making goodof disturbed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommendedby the manufacturer. 130 (F) AMF Panel Specification shall be as per manufacture instruction.Note :-The contractor shall be arrange for artificial load resistive for testingof DG set at site and the cost is deemed to be included in the quoted ratesMAKES :- Make of engine : CUMMINS/KIRLOSKARGREEN/ASHOK LEYLAND/ GREAVES COTTON.Make of alternator : KIRLOSKAR GREEN / ALSTOM / CROPTON GREAVES /SIEMENS 131 Supply, erecting,testing aand commissioning of solar water heating system with heat exchanger for cold & warm regions respectively with solar evacuated tube collection conforming to IS : 12933 (Part - i ) with amdt No 1 and IS : 12933 (Part 2) /2003 suitable for inlet water with chlorine and fluorine content up ot 100 ppm and supply hot water at the outlet of 200 litters capacity with elctrical back up meeting specifications as under and comprising of followings :-Supply and fixing rotational moulded polyethylene water storage tank (Cylindrical Vertical with closed lockable top with lid and locking arrangement) hoisted and fixed in position all as specified in SSR Part -I of capacity 200 Litters complete for storage of cold water feeding to solar water heater, including staging made out of MS Angle iron 50x50x6 mm all as specified and directed at site by Engineer-in-Charge.Material :- Soalr water heating System : Comprising of solar Evacuated tube Collector, Collectors stand assembly.Staniless steel insulated hot water Storage tank with heat exchange and various other components . Solar evacuated tube collector component shall have :Evacuated tube collector component shall have : solar Evacuated tube collector cover plate made of toughened glass.Sheet for absorber made of copperAbsorber made of copper sheet and copper tube.the minimum thickness of Aluminium shall be as under:- (a) Channel section for sides 1.6mm (b) Sheet for bottom 0.7 mm (c) Support for glass retaining 1.2 mm sheet for entire body 1.0 m AbsorberAbsorber shall consist of riser, header and sheet for absorer. The diameter of header shall be 25.4 +/- 0.5 mm and thickness 0.71 mm. The Diameter of riser shall be 12.7 +/- 0.5 mm and thickness 0.56 and made of copper only. 132 S & F Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore complete all as specified and directed. 133 Rain water Harvesting /Recharge PitS & F 150 MM perforated UPVC pipe with 20% Perforation complete all as specified and directed. 134 S & F 150mm bore PVC (SWR) vent cowl complete all as specified and directed. 135 M&L for hand packed gravel (Stone chips 12.50mm) for filling in bore holes and inside of recharge pit complete all as specified and directed. 136 Boring for 350 Mm Dia bore to a depth of 40 mtr in soil and getting out and disposal of spoil to a distance of 50 mtr using DMC method ( Direct mud Circulation) complete all as specified and directed. 137 GRIHA RATING FOR FOLLOWING BUILDING:-Minimum 3 star GRIHA rating shall be obtained for the following buildings which includes pre-certification and final ratings from approved aggency(a) OFFICER/ ADMIN BLOCK (b)SINGLE living JCOs ACCN(c) SINGLE living HAV/OR ACCN (T/S)Note :- 01The GBA (Green Building adviser) ofr obtaining GRIHA certification shall be approved by Accepting Officer.02. The GBA shall be responsible for all necessary actions for obtaining final GRIHA rating as per following guide lines:- (a) Pre-Cretification :-1. Submission of GRIHA per certification documents to certification agency as applicable immediately after the issue of Job/Work order.2. Analysis and suggest improvement/correction in the MEP/Other relevant drawings/documents and draft tender of the subject work for GRIHA star Rating (Min Three Star).3. Preparation, Submission & uploading all the documents in accordance with the GRIHA requirment, documentation shall be supported by drawings, test result quipment catalogues & calculations.4. Selection of equipment & material.5. To facilitate the planning team for selection of appropriate energy efficient & eco -friendly technologies, equipment & materials for the building e.g lighting system ,white goods, water treatment technologies, renewable energy, nontoxic paints, rapidlly renewable materials, recycled materials, ecofriendly materials etc.6. preparation of vendors & suppliers list for inclusion in the tender & working out specification of equiptment & materialto suit the GRIHA requirement. 138 7. Develop templates for GRIHA calculations to achieve certain points, this include materials related criteria, construction of waste management at site, energy calculation etc.8. conduct solar path analysis for each to achieve the best design ( shading device, Orientation etc.)9. Conduct solar path analysis for each fenestration to achieve the best design ( shading device, orientation etc)10 Perform day light analysis to ensure optimun condition achieved as per the guidelines provided by ECBC 2007.11. Perform day light analysis for window -wall ration, glass peropertiies (SHGC) & Providing recommendations to meet the compliance of ECBC 2007.12. Perform hourly calculation to show that thermal comfort condition as well as non-condition area are cachieved.13. Perform energy simulation to predict the energy performance of energy system in the bldg is less than the benchmarked energy perfomance as prescribed by GRIHA.14. Submit of ECBC compliance document to show that compliance fo mandatory requirment of ECBC are meet.15.Submission of draft specification to comply with relevant criteria of GRIHA for inclusion in tender documents.16. Liasoning and coordinating with GRIHA team for registration of project, uploading relevant document. Responding ot queries, observations, modification and corrections given by GRIHA team within specified time framed and reporting client with lates update.17. completion of all documentation requirement and formatlities before conclusion of main bldg. Contract and obtaining pre-certification with 3 or above star rating. 139 Final Rating:-Acquiring of Final Post GRIHA (minimum 3 star rating) certification approval from GRIHA including changes in drawings/ design during execution of work.Note:-The consultancy fees is inclusive of the following:-1. Pre-certification Registration Fees2. Certification registration Fees3. Site visit of GRIHA Official4. Site visit of GRIHA Official5. Third party EvaluatorPayment Schedule :-(i) 10% after pre-certification(ii) 50% at finalisation of specification(iii) 40% after obtaining GRIHA certification 140 Providing and fixing white vitreous china floor mounted water closet of size 360X640X685 mm of approved shape including providing and fixing vitreous china cistern with duel flush fitting, of flushing capacity 3 litre/6litre (adjustable to 4litre/8litre, including seat cover, and cistern fitting nuts, boltsand gasket etc complete all as specified and directed.Model No: SLS-WHT--6851P of make Jaquar of equivlent make/model as specified in Appendix D. 141 Providing and fixing white vitreous china wash basin for under counter mounting, specially fabricated brackets, painted whit, brass tap, 32 mm C.P. Wast, 15mm C.P. Brass self closing tap, connection pipe & rubber adopter for waste connection, complete including cutting and making food the walls, wherever requird complete all as specified and directed.Cat No : CNS_WHT_705 for wash basin ofmake Jaquar& Cat No PRS-031 for 15mm C.P brass tapof make Jaquar or equivlent make/model as specified in Appendix D. 142 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. Size 485 X 310 X 710 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitablebrackets all as per manufacturers specification and direction of Engineer-in-Charge.Cat No : URS-WHT-13255 of make of equivlent make/model as per Appendix D 143 Providing and Fixing of P.V.C waste Flexible pipe 40mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 144 Providing and Fixing of P.V.C waste Flexible pipe 15mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 145 Providing and fixing C.P. Brass angle valve 15mm dia for basin mixer and gyser pointsconforming to IS : 8931 complete all as specified and directedCat No FLR-CHR-5053N of make of equivlent make / model as per Appendix D. 146 Providing & fixing Liquid soap container of standard shape with bracket of the same material with snap fitting of approvedquality and colourcomplete all as specified and directedCat No : CAN-1135N of make of equivlent make / model as per Appendix D 147 Provinding & fixing Sink cock 15mm nominal bore of approved quality and colour complete all as specified and directedCat No : FLR-5347ND of make of equivlent make / model as per Appendix D 148 Provinding & fixingCP Brass Health faucet with 1.5M S.S Flexible Tube with wall hook including screw, Nut, bolts, cutting wall/floor and making good the same whatever required complete all as specified and directedCat No : ALD-CHR-583 of make of equivlent make / model as per Appendix D 149 Provinding & fixingCP Brass Bid cock Including wall fange, Connections, screws, nut, bolts, cutting wall/floor and makiing good the same whatever requiredcomplete all as specified and directedCat No : FLR 5037Nof make of equivlent make / model as per Appendix D 150 Provinding & fixing sink CP Wall mount double Robe Hookfixed to wooden cleats with C.P Brass screws, cutting wall/floor and making good the same whateverrequired complete all as specified and directedCat No : CAN-1161N of make of equivlent make / model as per Appendix D 151 Providing and fixing of straight type Macfit Single body push fit type WC pan connector with factory supplied srpring loaded seal guard of mcalpine, UK with integral single mould sealing fins made of flexible eva body, including bush/ adaptor for use with C.I pipe as supplied with the pan connecrtor complete all as specified and directed. Model : MAC 1 of make Macalpine of equivlent Model as approved by E-In-C or Accepting officer. 152 HOT WATER SUPPLYSupply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 15 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 153 Supply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 25 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 154 S&F CP Brass stop cock (concealed) of 100mm dia of standand design conforming to 15:8931 complete all as specified and directed. 155 Providing and fixing sound insulated PP piping system as per ON EN 1451 _ Part I-6 & EN 12056 part I-5 with 3 Layer pipe made of PP-C +PP-MV+PP-C in Blue Ral 5014 (Halogen and calcium free) colour, Push-fit type, food safe having high impact and stiffness, offering sound level of not more than 22dBA at a flow rate of 4 I/S and having pipe ring stiffness as per ISO/DIS 9969 and tightness as per EN 1277/B and C and DIN 19560 with all necessary fillings in blue colour, filled with factory fitted lip ring of make : Polyplast or equivalent make as approved by GE suitable for PP110mm dia Pipes complete all as specified and directed. 156 All as per item No 14.24 here-in-after but for PP 75mm dia pipes 157 All as per item No 14.24 here-in-after but for PP 40/50mm outer dia meter pipe (For wash basin etc) 158 Providing and fixing floor trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connection, 110mm inlet& 110m outlet long hight complete all as specified and directed. 159 Providing and fixing 110 X 50mm UPVC Floor Drain / Plain Floor trap complete all as specified and directed. 160 Providing and fixing SS Grating Over Floor Trap& Floor Drain 127 X 127mm complete all as specified and directed. 161 M&L concrete bed to drain pipe including packing under and lacking against the side of pipe after they are laid and tested with PCC (1:4:8) type D-2, for 110mm dia complete all as specified and directed. 162 All as per srl item No 14.30 here-in-after but for PP 40/50mm outer dia meter pipes. 163 S&F clean out cap plug (FCO/COP) for cleaning of same materials (POLO KAL NG) for PP 110mm dia complete all as specified and directed. 164 S&F 3-layer PPR-polypropylene random copolymer conceled pipes SDR 7.6 (PN-16) UV stabilized and antimicro bial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fitting for 50mm outer dia laid in trinches complete all as specified and directed.
Contract Date: Mar 17, 2026 Contract Value : 59.85 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
West Bengal View Result →
26.
Power #9680162 Technical Bid
Tender For Design, Engineering, Manufacture, Survey, Supply, Transportation, Erection, Testing & Commissioning of 33kv PTR Bay, 11KV ID Switchgear and other Mislanious works at under construction Recieving station at Balakote Dharati on Turnkey Basis.” under the jurisdiction of Executive Engineer, Sub Transmission Division KALAKOTE, JPDCL Jammu -1 SITC of 3.15 MVA 33/11KV Power Transformer; ( EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 2 3.15 MVA 33/11kV, ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections. 3 Providing & Fixing of Al Bus bars for transformer terminals of suitable size with color coding, heat shrinkable sleeves covered including drilling, welding etc as per requirement to be fixed on LV side of transformer as per relevant Standards 4 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 5 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 6 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 7 33 kV Isolator With Earthing Blade with allied accessories and pad clamps (36kV,1250A, Outdoor, 3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.)For 33kv Line. 8 Installation of Capacitor Bank (INCLUDING ALL CIVIL WORKS & EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 9 11 KV Capacitor bank 1.2MVAR with VCB Panel and complete arrangement for connection with 11 KV incomer panel, Series Reactor, Isolator, RVT, Surge Arrestor, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with Structure, foundation and accessories. 10 33 kV TRANSFORMER BAY ( EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 11 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) with allied accessories and heavy duty pad clamps. 12 33 kV Isolator with Without Earthing Blade with allied accessories and pad clamps (36kV,1250A, Outdoor, 3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 13 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 14 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less (1 Set for Line & 2 Set for stn) 15 33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, DLMS Compliant with RS-485 port 16 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ) 17 SITC OF CONTROL CABLES 18 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 19 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 20 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 21 Lugs, Ferrules etc. 22 SITC OF CONDUCTOR & HARDWARE 23 Providing & Fixing 200 mm² ACSR Conductor Panther 24 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 25 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 26 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 27 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthing by GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 28 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clamps as per relevant Standards 29 11 kV INDOOR SWITCHGEAR OF 6.3MVA, 33/11 KV SUBSTATION; (INCLUDING ALL CIVIL WORKS & EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 30 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, (1+3)SET 31 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets) 32 11 kV 3- Core XLPE 300 mm² armoured, FRLS 33 11 kV 3-Core XLPE 120 mm² armoured, FRLS 34 11 kV Indoor Heat Shrinkable Cable Termination Kits 35 11 kV Outdoor Heat Shrinkable Cable Termination Kits 36 11 kV Indoor Heat Shrinkable Cable Termination Kits 37 11 kV Outdoor Heat Shrinkable Cable Termination Kits 38 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. 39 9 Mtr. Long Pole(ST-410 SP33) 40 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 41 Galvanised iron of sorts including CH Angle brases Clamps etc. 42 100 KVA, 11/0.433 KV, 3-Phase Distribution Transformer with Bimetallic Terminal connectors Energy Level -2 (Alminium wound) 43 120 mm² PVC LT Cable 4 Core, armoured, FRLS 44 Cement bottoming 1:2:4 mix as per REC standards. 45 Earthing of 100 KVA Substation-Excavation of earht pit of dia 650 mm & depth 3000 mm installation of earthing pipe of 40 mm Nominal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239 GI Strip[ for neutral earthing of size 75 mm x 10 mm & 50 mm x6 mm for connection of transformer body, G.O set & lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. 46 Supply ,Installation Testing and Commissioning of Earthing Complete by GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm. 47 11kV Bus Bar Fuse Set Out Door type for Auxilary Transformer 48 G.I Chainlink Fencing of 33kv Reciving station by way of mass concreting in foundations and chainlink fencing of 6 ft height using G.I Angle of size 65x65x6mm and G.I Flat iron 50x6mm including Main Gate 14feet*6feet complete job. 49 SITC of 120 Watts LED Street lights 6 Nos of following watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on 13mtr ST Pole 2 Nos including necessary boxes/fabrication/modification as per requirement. ( The LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.) 50 COMMON MISCELLANEOUS EQUIPMENTS 33/11kV SUBSTATIONS; (INCLUDING ALL CIVIL WORKS & EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 51 a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply . 52 Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories 53 Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCBs (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories 54 Providing of Rubber Mat 1mx2m 19mm thick 55 Providing of Fire Extingiusher Co₂/ABC Type of 4.5 kg capacity for control room 56 Providing of 3 Sand Bucket Fire Extingiusher with metallic stand and identification plates 57 Providing of Industrial safety Helmet 58 Providing of Rubber Gloves for 33 kV level 59 Providing of Rubber Gloves for 11kV level 60 Providing of Tool Kit case plastic of Harry-kerry make of 2.5x1x1.5 feet dimensions with different chambers 61 Providing of Clamp meter with multi measuring parametersMarkoni/motwane/fluke make 62 Providing of Screw driver tester neon lamp based 63 Providing of Aluminum industrial ladder split 40 feet extension type withallied accessories 64 Office Steel Chairs wih Armrest 65 Office Table of Standard Size with Sufficient Drawers 66 Office Almirah With Locker of reputed make 67 Cement Concrete R/B Wall as per site requirement, as per the direction of site Engineer. 68 SITC OF 11 kV LINE 69 9 Mtr. Long Pole( ST-410 SP15) 70 GI cross-arm with top Bracket including clamp 71 GI Braces and Belts including Clamps etc 72 50 mm² ACSR Conductor 73 PG Clamps for 50 mm² ACSR Conductor 74 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 75 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 76 Galvinized Nuts and Bolts 77 Danger Plates with Clamps 78 Anti-Climbing Device with Clamps 79 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 80 Red Oxide 81 Aluminium Paint 82 Cement bottoming 1:2:4 mix as per REC standards .45cum /pole 83 Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete 84 Sign Board for Receiving Station With JPDCL Logo.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
28.
Petroleum and Natural Gas #9630202 AOC
Bids Are Invited For Supply Of 8 Channel Field Terminal Unit-24 Vdc , Supply Of Dual Compartment Flp Or Wp Enclosure , Supply Of 24V Ftu Power Supply Card , Supply Of 5 Vdc Ftu Power Supply Card , Supply Of Ftu Mounting Accessories , Supply Of Flp Hooter 230Vac Baliga Make , Supply Of Infrared Gas Detectors , Supply Of 4-20Ma Transmitter , Supply Of Sensor Mounting Accessories With Window Junction Box For Sensors , Supply Of Modified Gms Software , Supply Of Modified Mimic Repeater Panel With Layout , Modified Cpu Or Ciu Card , Supply Of Flp Jb 4 Way , Supply Of Weather Proof Junction Box-Power And Signal , Supply Of Flp On Or Off Switch , Supply And Installation Of Surge Protection Device For Gms , Supply Of Flp Jb Push Button With Ack Switch , Flp Heavy Duty Double Compression Cable Termination-Flp. Copper Lugs For Copper Cables And Aluminium Lugs For Aluminium Cables Shall Be Used. , Cabling And Allied Works - Armoured Cables Supply And Laying Of Xlpe Insulated Pvc Sheathed Copper Conductor- 3 Core X 1.5 Sq. Mm. Copper Frls , Installation,Testing And Commissioning Of Sensor And Mounting Accessories , Installation,Testing And Commissioning Of New Ftu And Accessories,Etc., , Installation Of Flp Jb, Enclosure And Mtg.Accessories For Ftu An Jb , Installation Of Flp Hooter , Erection And Installation Of Cpu,Mimic And Software , Testing And Commissioning Of System , Dismantling Of Old Gms Panel Including Ftu ,Cables,Etc In All Complete Aspect. , Cable Brick Duct Providing And Constructing Underground Brick Duct 650Mm Below Gl -225 Mm -16 Bricks And 0.0195 Cum Per Mtr , Supplying And Installing Of Gi Cable Route Marker With 100Mm X 100Mm X5mm Thick Gi Plate. , Supplying, Fabricating And Installing Following Sizes Of Perforated Gi Cable Trays - 150Mm X 50Mm X 2Mm , Providing And Laying Class-B 50Mm Dia Gi Pipe For Cable Routing Under Flooring Or Eb Post Leading Including Sealing Both Ends With Jute And Bitumen Total Quantity : 2244
Contract Date: Ref. Documents Contract Value : 21.81 Lakh
Boards / Undertakings / PSU No of Bidders 1
29.
Defence #9609205 AOC
Tender For Provision Of Watering Facility, Bty Charging Room And Lighting For Arf At Cod Delhi Cantt-10.; 7 S&F exhaust fan of metallic body single phase 230/240 Volt AC of size 380 mm sweep, 1400 RPM heavy duty with louvers complete all as specified & directed. 8 S&F ceiling fan 1200 mm sweep efficiencia DX BLDC model with five star rating white colour including with all necessary accessories ie speed regulator, rubber reel, clamps, locking pins, nut bolts, canopy & down rod complete all as specified and directed. 9 Supply, layingjointing,testingDIpipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches of 100mmbore dia of pipe complete all as specified and directed. (Note : Tyton Joint, Excavation & earth work shall be measured & paid separetely.) 10 Material and labour for DI specials like bends, tapers any type any radius and angle, Tee pieces single branch `Y junction, double branch, cross (all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore. 11 Material and labour including jointing and testing of cast iron sluice valves class PN-1.0, conforming to IS:14846 flanged ends drilled having stainless steelspindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluice valve and removal from sitefor 100mm bore complete all as specified and directed. 12 Supply and installation of flanged ends Water Meterwoltman type, including testing and making good connection with flanged ends, with gasket rubber sheet and nut & bolts etc ISI Marked fixing in horizontal/incline/vertical position,including taking out unserviceable of 100 mmbore complete all as specified and as directed. 13 M&L for installation of flanged ends strainer/dirt box, PN-10 with stainless steelmesh suitable for water meter for potable water supplies on up stream of water meter to avoid foreign material entering into meter including taking out unserviceable of 100 mmbore complete all as specified and as directed. 14 Supplying , laying , jointing, welding and testing MS Pipe (Heavy class C) IS : 1239/3589, of followiing sizes laid in trenches or in Horizontal/Vertical/inclined position orlaying on floors for connectionsfor suction, to header andconnected to out going water main CI/DI pipe line, for 100 mm DiaNote:- MS Flangesincluding fabrication work will be measured and paid separately. 15 Supply and fixing in renewal of MS flange 100 mm bore ,16mm thick duly welded with flange joint including nuts bolts ,washer ,Rubber or fiber board gasketjoint of 100 mm size complete all as specified and directed. 16 Supply, install, testing & commissioning of Factory Made 11 KV, 400 Amps, 21 kA for 3 Seconds, SF6 Insulated, Motorized, Outdoor, 3 Way RMU Consisting of 2 Nos VCB Incoming and 1 Nos VCB Outgoing for Feeder complete all specified and as directed and shall comprise of the following: 17 [A] RMU shall be 11 KV, 400 Amps, 21 kA for 3 Seconds, SF6 Insulated, Motorized, Outdoor, 3 Way RMU, Right side Extensible with Air Insulated Bus Connected Metering unit, Type tested in line with latest IEC Standards, suitable for operations at a height up to 1000 Meters above sea level and at 40ºC Ambient Temperature without any de-rating, Switchgear and Busbar shall all be contained in a Stainless Steel Enclosure [Minimum 2mm thick AISI 441 Grade] filled with SF6 at 0.3 Bar [300 hPa] Relative Pressure, RMU Tank shall provide Full Insulation and Switchgear shall be insensitive to the environment with Degree of Protection of IP67 immersion for 30 minutes as per IEC Standard 60529, Switchgear Operating Mechanism shall have an IP2X Protection and Cable Chamber shall have IP3X Protection, Outer Enclosure shall be IP 54 type tested, Powder Coated with Pure Polyester Based Paint, suitable for the site installation conditions, Accidental Overpressure due to an Internal Arc is limited by the opening of the safety valve, at the bottom of the metal enclosure, away from the operator, Plug in type of extensibility must be provided and coupling busbar should not be exposed to air to avoid oxidation of busbars. Extension of cubicle shall require 450mm to handle and the gap between the coupled RMU’s must be within 10mm. 18 [B] Vacuum Circuit Breaker [VCB], comprising of the following: [i] 11 KV, 400 Amps, 21 kA VCB with Manual / Motorised Spring Assisted Mechanism and Series Trip Coil – 1 No, [ii] Load Break Switch with Built-In Earth Switch – 1 No[iii] Position Indicator through clear front mimic in line with IEC 62271-103 – 1 No[iv] Self Powered Relay with O/C, S/C, E/F Protection. Relay shall have a Front USB / RS485 / RS232 Port for Laptop Interface / Modbus Communication, LCD Display, 10 Event Records, 5 Fault Records, min 2 setting group and keypad for setting parameters for the relay – 1 No[v] CT Ratio 200-100/1-1A for Incoming, 100-50/1-1A for Outgoing and, Class - 1.0, 2.5VA for Metering and Class 10P10, 2.5 VA for Protection – 1 Set[vi] Live Cable Indicator with indication at the Front and Three Inlets to check the Synchronization of Phases – 1 No[vii] Cable Termination Bushing suitable for up to 1 Run, 3 Core, 185 Sq.mm, XLPE Cable – 1 Set[viii] Cable Termination Cover Boots [Push on type] – 1 Set[ix] Fault Passage Indicator FPI. 19 [x] Circuit Breakers shall have Two Positions: Open or Disconnected and Closed. A separate and independent 3 Position Earthing Switch and disconnector shall be fitted to open and earth the cables in such way that interlocks prevent all unauthorised operations. An operating mechanism shall be used to manually close the circuit breaker and charge the mechanism in a single movement. An independent mechanism shall be fitted for the 3 Positions Earthing Switch and Disconnector Circuit breaker shall be fitted with a local system for manual tripping by an Integrated Push Button. There shall be no automatic reclosing. Circuit Breaker shall have a min of 2000 Mechanical and Electrical Operations and 50 Nos Short Circuit Operations, Disconnector and Earth Switch shall have a minimum of 1000 [M1] Mechanical Operations, 100 Electrical Operations at rated current and 5 Nos Operations at Rated Short Circuit Current.[C] Air Insulated Bus Connected Metering Unit comprising the following: – 1 Set[i] Air Insulated Enclosure with necessary Bus Connection – 1 No[ii] PT 11KV / RT 3 / 110V / RT3, 25 VA, Class-1.0 – 1 Set[iii] Voltmeter with Selector Switch – 1 No[iv] R / Y / B Indicating Lamps – 1 Set 20 [vi] Battery and Battery Charger, 12 Ah, [I/P-230V AC, O/P - 24V DC] – 1 No[v] 11 KV / 230V AC, 1 KVA Control Transformer-1 No[vii] Self Powered FRTU to detect Short Circuit and Earth Fault on the Cable System, Fault indication through LED Lamps, Reset through Remote and Local. As a minimum, the FRTU shall be capable of performing the following functions: [a] Acquiring Analog values from Multifunction Transducers or alternatively through Transducer – less modules and the status inputs of devices from the substation, processing and transmitting to Master stations. Capability to acquire analog inputs from analog input cards receiving standard signals viz. Current Loops 4 – 20 mA, etc.[b] Receiving and processing Digital Commands from the Master Station[s] [c] Data transmission rates – 300 to 19200 BPS for Serial ports for MODBUS and 10/100 MBPS for TCP/IP Ethernet Ports[d] Use of IEC 60870-5-104 Protocol to communicate with the Master Station[s][e] Use of MODBUS over RS485 interface, Protocol to communicate with the MFTs, Protection Relay. 21 [f] Have required number of Communication Ports for simultaneous communication with Master Station[s], MFTs.[g] FRTU shall have the capability of Automatic Start-Up and initialisation following restoration of Power after an outage without need of manual intervention. All restarts shall be reported to the connected Master Stations.[h] Remote Database downloading of FRTU from Master Station from SCADA/DMS Control Center.[i] Internal Battery Backup to hold Data in SOE Buffer Memory & also maintaining the Time & Date.[j] Communication with at least Four Master Stations simultaneously on IEC 60870-5-104[k] RTU shall be capable of Acquiring Analog Values through Transducers having output as 4-20 mA, 0-10 mA, 0-+10 mA etc using Analog Input Modules.[l] FRTU shall have one TCP/IP Ethernet Port for communication with Master Station[s] using IEC 60870-5-104 Protocol.[m] FRTU shall have one Serial RS 485 Port for communication with MFTs and connected in daisy chain using MODBUS Protocol. Minimum 15 Analog Values [Including 4 Energy Values] shall be considered per energy meter. 22 [viii] Connection with adjacent modules shall be direct through busbar via metering bushing or through MV cables. VT’s and CT’s from the manufacturer conforming to IEC61869-3 and IEC 61869-2 respectively shall be accepted.Note:[a] The make of Vacuum Interrupter, FRTU offered shall be of the same make as of the Ring Main unit.[b] An operator situated in front, lateral and rear [A-FLR 21kA – 1 Sec, Downwards Exhaust, for Tank as well as Cable Compartment] of the RMU Switchboard during an internal fault shall not be exposed to the effects of Arcing. Internal Arc Type Test Report for IAC AFLR 21 kA for 1 Sec for both Tank & Cable Box shall be for minimum 3 Way / 3 Function RMU.[c] All operations shall be from front of the RMU, including access to cable bushings. Bushings along the sides or the rear of the RMU are not acceptable. 23 [d] Construction of Plinth / Foundation for 11KV RMU: The rate quoted is deemed to be including the cost of Plinth / Foundation and shall be paid extra on this account. The foundation shall consists of Two Parallel Brick Walls built using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:6 of length 2.10m, suitable thickness and height as per the manufacturer’s instructions over PCC Concrete Bed of 150mm thick in PCC 1:4:8, Type D-2, using 40mm graded stone aggregate over 150mm thick Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding15 cm thick watered and rolled, over 150mm thick Sand Bed, rendering to brick surfaces, 15 mm thick in Cement Mortar 1:4, and finishing the top surface even and smooth without using extra cement, applying Three coats of white washing including earthwork excavation of pit size 2.10 X 1.20 X 0.60 Metres complete all as per manufacturer’s recommendations, drawings, as specified and as directed.[e] The rate quoted is also deemed to be including the cost of disconnection of HT Cables up to 3 Core, 240 Sq.mm from existing 2 Pole / 4 Pole Structures, removing of cable loop and reconnection to RMU complete all as specified and as directed by the Engineer-in-Charge.[f] End termination joints shall be measured and paid separately. 24 Supply, Installation, Testing & Commissioning of OEM Factory Manufactured, Floor Mounted, Outdoor Type,ICOG (Cable-In, Cable-Out) type,HT 11 KV Air Insulated VCB Panel Switchboard consisting of 400 Amps, 25 KA, VCB 11 KV – 1 Nos, VCB Panel shall be Outdoor Type totally enclosed, Free Standing Floor Mounting Type, compartment based with Truck Mounted Vacuum Circuit Breaker, Spring Operated, Electrically and Manually charged Operating Mechanism suitable for Horizontal Isolation, Horizontal draw out type VCBs with Aluminium Busbars, Self supported Insulated Busbar with full voltage rated, Complete VCB Panel conforming to IEC 62271-200 Standards and IP 4X Class of Protection comprising necessary bus-bars extension and connections and following Protective and Control Devices as specified below. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. Circuit Breaker, Vacuum Interrupter and Relay shall be of the same manufacturer. The Switchgear and Control Gear Panels shall be of the fully Arc Proof complete all as specified and as directed.Make: ABB / CG / Schneider / Siemens. 11 kV Outdoor Switchgear Panel consisting of Breaker of capacity 400 Amps, 25 kA Draw out type and shall have the following accessories: [a]230 Volts AC Spring Charge Motor 25 [b]110 Volts DC Closing Coil[c]110 Volts DC Shunt Trip Coil[d]Current Transformer, Indoor Resin Cast Ratio: 100-50/5-5A Core – 1: 15VA Class 0.5, Core – 2 15 VA 5P10 Core -3.[e]Potential Transformer Resin Cast Ratio: 33KV/√3/110V/√3 50VA, CLASS: 0.5 – 3 Nos[f]12 Window Annunciator[g]Digital Ammeter with ASS[h]Digital Voltmeter with VSS[i]Multifunction Power Meter Class 0.5 with RS485 & Ethernet Communication [j]Master Trip Relay[k] Numerical Relay Differential Protection [87T] - 01 No. 26 [l]Numerical protection IEC 61850 Draw out Relay with graphical display- 1 No. with three phase O/C & E/F (50,51, 50N, 51N, 50G, 51G), three phase Directional O/C & E/F (67/67N), Negative phase sequence O/C (46), Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three phase O/V, U/V & NDR (27, 59, 59N), thermal overload (49), Negative sequence over voltage (47), reverse power (32), Over frequency (81O), under frequency (81U), CT Supervision (60CTS), VT Fuse Failure (60 VTS), Auto recloser (79), relay shall have 8DI and 8 DO. [m] Power pack 100W with battery back up.Makes: ABB/CG/Schneider/Siemens. 27 Supply, installation, testingand commissioning in replacement of factory made testedLT Panel compartmentalized cubicalOutdoor type canopy headed Floor mounted suitable for , 415 volts 3 phase, 4 wire,50 HZ AC supply system having bus bar chamber with insulated aluminum bus bar of rating 1.5 times that of controlling MCCB supported on SMC insulator. The panel should be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and 50X50X6 mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on out side surface and painted in side with two coat of red oxide primer and rear opening type with apron for cable entry, closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size and comprising of the following including necessary foundation platform of suitable size 28 NOTE:-(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) All MCCB Should have spreader link with barrier. (I) Incoming :- (i) MCCB 4P, 630 A, 36 KA, Icu = Ics = 100%, thermally adjustable between 60 to 100% - 01 Nos.(ii)Digital Voltmeter 0-500 volts, square, 96 mm,flush pattern with 3 way selector switch - 01 No(iii)Digital Ammeter 96mm x 96 mm,flush pattern with 3way selector switch- 01 No.(iv) 3 Nos of CTs ofratio500/5 copper wound, Class 1.0, 10 VA – 1 Set(iv) Indicating lamps R,Y and B Phase :01 set of three(II) Outgoing :-(i) MCCB 4P, 400 A, 25 KA, Icu = Ics = 100%, thermally adjustable between 60 to 100%= 02 Nos.(ii) MCCB 4P, 100 A, 16 KA, Icu = Ics = 100%, 415 Volt, 50 Hzs= 02Nos. 29 Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing ofHDPE/GI pipe 80 to 100 mm bore and making good both ends complete all as specified and directed. 30 Demolition of road, path, drain and concrete in ground floors, RCC/Brick wall (below or above ground level) complete all as specified and as directed. 31 Platform :- M&L for Brick Masonry ( Using sub class B Brick) platform of size 3m x 3m x 1 m height , built in CM 1:4 complete with excavation & earth work , PCC 1:4:8 type D-2 in foundation , 15 mm thick rendering in CM 1:6 on sides and top of the brick work , up to 150 mm below ground level , supply and fixing of 02 Nos MS Channels ofsize ISMC-100for balancing of Transformerembedded in PCC 1:2:4 type B-1 up to 100 mm thick RCC 1:2:4 with 10 mm steel bar including 20 mm graded aggregate , including provn of steps on one side complete all as specified and directed . 32 S&F for Angle iron, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.. 33 Supply drawing, connecting and testing of3 core, 2.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 complete all as specified and directed. 34 S&F 4 mm thick mild steel wire 75x25 mm mesh up into mattressess or cages, lapped wired and fixed in position including welded for fencing to grid including one coat of primer and two coat ot synthetic enamel paint complete all as specified and directed.
Contract Date: Feb 19, 2026 Contract Value : 79.61 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
30.
Defence #9578160 AOC
Tender For Provision Of Otm Accommodation (Phase -I) At Bagrakote Under Ge Sevoke; 1 BUILDINGS & STRUCTURE (Sch A PART-I) 2 Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 36,31,20,000.00 inserted by the MES in Schedule ‘A’ Part-I. 3 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch A PART-II) 4 Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 52,49,260.89 inserted by the MES in Schedule ‘A’ Part-II. 5 INTERNAL WATER SUPPLY (Sch A PART-III) 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 46,308.98inserted by the MES in Schedule ‘A’ Part-III. 7 INTERNAL ELECTRIFICATION (Sch A PART-IV) 8 Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 96,32,540.67 inserted by the MES in Schedule ‘A’ Part-IV. 9 ROAD, PATH & CULVERT (Sch A PART-V) 10 Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 86,86,643.57 inserted by the MES in Schedule ‘A’ Part-V. 11 SEWAGE DISPOSAL (Sch A PART-VI) 12 Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 23,70,861.02inserted by the MES in Schedule ‘A’ Part-VI. 13 AREA DRAINAGE(Sch A Part-VII) 14 Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 64,06,702.01 inserted by the MES in Schedule ‘A’ Part-VII. 15 CHAIN LINK FENCING AND GATE (Sch A PART-VIII) 16 Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING AND GATE )”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 16,99,635.84 inserted by the MES in Schedule ‘A’ Part-VIII. 17 EXTERNAL WATER SUPPLY (Sch A PART-IX) 18 Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,04,432.28inserted by the MES in Schedule ‘A’ Part-IX. 19 EXTERNAL ELECTRIFICATION (Sch A PART-X) 20 Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 66,58,717.06 inserted by the MES in Schedule ‘A’ Part-X. 21 FIRE FIGHTING & FIRE ALARM SYSTEM (Sch A PART-XI) 22 Lump sum price worked out by the Contractor for “FIRE FIGHTING & FIRE ALARM SYSTEM”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 32,30,010.00inserted by the MES in Schedule ‘A’ Part-XI. 23 HOT WATER SUPPLY (Sch A PART-XII) 24 Lump sum price worked out by the Contractor for “HOT WATER SUPPLY”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 6,63,253.28 inserted by the MES in Schedule ‘A’ Part-XII. 25 LIGHTNING PROTECTION (Sch A PART-XIII) 26 Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 29,821.10 inserted by the MES in Schedule ‘A’ Part-XIII. 27 COOLING APPLIANCES (Sch A PART-XIV) 28 Lump sum price worked out by the Contractor for “COOLING APPLIANCES”as listed in Schedule ‘A’ Part-XIV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,24,714.16 inserted by the MES in Schedule ‘A’ Part-XIV. 29 DEMOLITION & DISMANTLING (Sch A PART-XV) 30 Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING”as listed in Schedule ‘A’ Part-XV.Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,25,480.08 inserted by the MES in Schedule ‘A’ Part-XV. 31 MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch A Part-XVI) 32 INTERNAL WATER SUPPLYS&F ofGun-metal, globe or gate valve, 65 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 33 S&F ofGun-metal, globe or gate valves, 80 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 34 S&F 15 mmbore brass CP mixer for hot & cold water screwed down for iron / CPVC pipe and fixed (3-in-1) complete all as specified and directed. 35 S&F 15 mm bore fancy type, chromium plated basin inlet connection (angle valve), cast copper alloy, screwed down, high pressure, screwed both ends for iron / CPVC pipe for unions and fixed complete all as specified and directed. 36 S&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron / CPVC pipe 15 mm borecomplete all as specified and directed. 37 S&F health faucet with stainless steeltube and wall hook suitable for 15 mm dia pipe with 1 meter long flexible tube including making connections and fixed in pipe etccomplete all as specified and directed. 38 INTERNAL ELECTRIFICATIONS & F modular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed.(AC& GYSER POINT) 39 S & F MCB 25A, 230 V, 50 Hz, 2P MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed. 40 All as per Srl Item No. 16.08 here-in-above but for 16A, 230 V, 50 Hz, 2P MCB (C curve) complete all as specified and directed. 41 S&F load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed. NOTE : Outgoing MCBs shall be measured and paid separately. 42 S & F of 125A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed. 43 S & F 40 W surface / wall mountedLED batten capable of delivering minimum 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 44 S & F 9W LED Study light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. 45 S & F surface mound Flame proof LED Batten, 20W, CRI > 70, suitable for Hazardous area group IIA and IIB and zone 1 & 2, IP 65 Protection with 100 lumens/watt with Die Cast Aluminium Housing, THD < 15% complete all as specified and directed. 46 SEWAGE DISPOSALConstruction of Septic tank (for 10 Users) conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brick wall RCC M-25 in Roof Slabetc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.30 meter complete all as shown on TD drawings No CESZ/2019/TD-115 Sheets 1/4 to 4/4 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 47 Construction of Soakage wells excavation, in any type of soil, walls of honey combed masonry, RCC cover slab in M25, bat filling interconnecting pipes of DWC complete filled with brick bats of size 1.20 M dia X 3.00 M effective depth complete all as shown on TD drawings No SZ/TD-14 Sheets 1/1 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 48 M&L for 200 mm (inner dia) DWCPE (SN-8) pipe as per IS:16098 (Part-I) with all fittings and laid in trenches and jointed complete all as specified and directed. 49 EXTERNAL WATER SUPPLYSupply, laying and testing of 150 mm bore ductile iron pressure pipe socket and spigot end, class K-7, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 50 Supply, laying and testing of 100 mm bore ductile iron pressure pipe socket and spigot end, class K-9, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 51 M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as shown TD Drawing all as specified and directed. 52 S& F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Water supply mains of size 150 mm dia complete all as specified and directed. 53 Supply and fix valve, reflux with by pass arrangement 150 mm (6) dia complete all as specified and as directed. 54 M & L for Trial bore of 200 mm dia below ground level in any kind of soil strata including hard stone/ boulder by deploying direct/reverse or universal method to achieve desired depth including cost of consumable stores like fuel,lubricants, bentonite mud, material and transportation of machinery etc., complete all as specified and as directed..NOTE : -(a) Erection and dismantling of boring plant including all arrangement for the transportation of boring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work.Pits for collection of water and water for drilling tubewell will be arranged by the firm/contractor at site his own cost.(b) Borewell to be done subject to permission by CGWB. 55 M & L for electro logging for identification of aquafier zone with report enterpretation, including fabrication of strata chart in wooden glass frame and strata box of size 1000x600x100mm made by woodshisham and 3mm glass in front of box for display in pump house complete all as specified and directed. 56 Reaming up to 350 mm dia for depth upto 60 mtr from ground level complete all as specified and directed. 57 Reaming up to 300 mm dia for depth from 60mtr from ground level to 110 mtr complete all as specified and directed. 58 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 250mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 59 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 200mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 60 All as per Srl Item No. 16.41 here-in-above but slotted pipe as per IS: 8110 strainer complete all as specified and directed. 61 S & F of end cap of for 200mm dia MS pipe, complete all as specified and directed. 62 S & F of MS reducer socket of 250x200 mm dia to be fabricated out of 12 mm sheet plate with the housing pipe of 250 mm dia for fixing 250 mm dia MS pipe to 200 mm dia MS pipe, complete all as specified and directed. 63 S & F of well cap of for 250mm dia MS pipe complete all as specified and directed. 64 S & F of clamp of size 150mmx10mm of length 1.5mtr including MS nut bolts of 10mm dia and washer etc for supporting casing pipe complete all as specified and directed. 65 S & F of clamp of size 150mmx10mm of length 1.0 mtr including MS nut bolts of 10mm dia with washer etc for supporting column pipe complete all as specified and directed. 66 S & F Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & boltsand washers etc for holdingcolumn pipes/GI pipes of submersible pump set, complete all as specified and directed. 67 S & F of cage fabricated from strips of size 25x4suitable for protection of submerssible pump set with two coat of anti corrosive black bituminous paint, complete all as specified and directed. 68 S & F of flat submersible cable 3 coremulti stranded copper conductor of size 6 sqmm ISI marked, complete all as specified and directed. 69 Supply and filling pebels of size 6 to 10mm around the casing pipe of borewell including all lead and lifts free from dust dirt or vegetation manure, complete all as specified and directed. 70 Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water of borewell using air compressor of 350psi , 600cfm pressure for required number of hours including fuel etc.,complete all as specified and directed. 71 Conducting following tests for the bore well to determine safe water pumping from government approved laboratory including submitting the report to the department, complete all as specified and directed :-(i) Yield Test(ii) bacteriological Test(iii) chemical test (systematic analysis) 72 S & F of FASD submerssible motor panel starter of capacity 7.5 HPincl overload,single phasing prevention, complete all as specified and directed. 73 Design, supply, installation, testing and commissioning Iron Removal/ water treatment Plant of capacity 40 Cum/Hr (8000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel over a coat of red oxide primer complete comprising of the followings :- Item Continued as 16.43 to 16.46 74 (a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. Theshell thickness shall be of 6 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - 900MM and Height on Straight - 750MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 75 (b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline 150 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand media having 915 mm media depth. The shell thickness shall be of 6mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Epoxy paint from inside and outside red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - 2000 MM and Height on Straight - 1875MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 76 (c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set 77 Note :- (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(i) Contractor has to carry out necessary water testing and design of the plant accordingly. Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (ii)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate. 78 Supply, installation, testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 200/250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. NOTE :The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. 79 Supply,installation, testing and commissioning open well Submersible pump of capacity 10 HP,electric driven 415 V, TPand completeinclusive ofsubmersible cable and starter including dry run preventor and single phasing preventor complete all as specified and directed. 80 M&L for DI fittings for spigot and socket pipes of size 80 mm to 350 bore such as bends(any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc)Tee pieces single branch, Yjunction, double branch, cross(all sockets or socket and spigot) collars caps and plugs complete all as specified and directed. 81 FIRE FIGHTING & FIRE ALARM SYSTEMSupply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed. 82 M & L for 2 core, 2.5 sqmm (for instrumentation)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 83 M & L for 3 core, 2.5 sqmm (for auto start/stop panel)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 84 S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. 85 S & F ofCL 150 # rated ball valve25 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 86 S & F ofCL 150 # rated ball valve80 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 87 M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI butterfly valve, 100 mm NB, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly). 88 M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed. 89 S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. NOTES: [i] Operating temperature :-300C to + 550C[ii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters[iii] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar 90 S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed:-Item Continued as 16.60 & 16.61 91 Sign of size 250 mm X 300 mm reading IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. 92 Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level. 93 S & F Galvanised Iron Fire bucket 9 ltr Red in colourheavy duty all as specified and as directed 94 EXTERNAL ELECTRIFICATIONS & L 50 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 95 S & L 75 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 96 S & L 90 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 97 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofand LT Fault Level 21KA , consisiting of 630A12 kV rated , 1 nos load break switchesas incomers &2 nos motorized type VCB as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar as per detailed description as follows:- Item Continued as 16.67 to 16.74 98 RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchboards drives shall have an IP2X protection index. The tank shall be made of at least 2mm unpainted stainless steel.SF6 gas is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered.SF6 gas used for the filling of the RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator. Number of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the SF6 enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only. 99 HT system : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. Enclosure of RMU must be IAC rated for 21 kA for 1 Sec. Design ambient to be considered as 40 Deg C.HT Circuit Breaker : i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall behorizontal isolation - horinzontal draw out type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2Aii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 1 secs. Iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%) , No. of Trip Coils - 02 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip Feature forseries trip shall also be enabled. iv) Provision for supervision of the two indepandent Trip Circuits for the two Trip Coils to be provided. v)Switchgear classification: PM classvi) Loss of service continuity class: LSC2A 100 vii) Duty Cycle : O – 0.3sec – CO – 3min – CO, Vacuum Circuit breaker shall be of M2, E2, C2 duty and capable for minimum 100 short circuit breaking operation at full short circuit level.viii) STC rating 21 kA for 1 Sec (for Vacuum Interrupter).ix)Vacuum Interrupter must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.xi) The Operating mechanism shall be spring charged motor operated type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.xii)Suitable monitoring of Circuit Breaker status ( ON, OFF, Trip, CB Spring Charged), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using IoT based online monitoring system using microprocessor / digital RTU with historical data saving, capable of updating status and sending alarm signal on IoT monitoring unit, GSM and GPRS platform through which live monitoring status and equipment reading and fault related history can be accessed by user remotely. 101 xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/CHT CT /PT i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 15 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 15 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV-6 kV /√3 / 110V/√3, Cl 0.2s, 100VACore 2- 11kV- 6 kV /√3 / 110V/3, Cl 3P, 50VA 102 Multifunction Meteriii) 2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments) .Protection Relayi) 2 Nos. of Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates. 103 ii) Master Trip Relay :High Impedance and High speed relay flush mounted having coil cut-off contact with at least 4NO and 4NC contact and electrical reset facility capable to make, carry and break trip coil current of Circuit Breaker and capable for future integration with SCADA.iii) Each VCB must have separate Anti Pumping Relay.Fault Passageindicator: 104 The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include:Fault detection - Phase to phase and Phase to earth faults.One potential-free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option –End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include:Phase fault thresholds configurable from at least 100 to 800 AEarth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds.Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 105 Earthing The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations.Separate line side Earth switches shall be provided in each HT Circuit ( against each VCB)RMU Bushing & Cable termination:It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cablesThe bushing should be conveniently located for working with cables specified and allow for the termination of these cables: -630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard.Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU. Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 400 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables ( for HT side) and at LT side runs of cables matching with outgoing MCCB current rating. 106 S&F 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed. 107 M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed. 108 S&F factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact(IK 08) totally insulatedmade of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable glandand one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed. . 109 S&F HT/LT made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint( HT cable 11 KV orLT cable 1100 Volts) on Cable route marker including necessary excavation and earthwork complete all as specified and directed. 110 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :-(i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 400 Amp 4 pole 01 Nos breaking capacity 36 KA , MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA,, thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. MCB SPN 32 Amp02 Nos. Item Continued as 16.80 111 (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 112 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 03 Nos, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA, MCCB 40 Amp 4 pole 01 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set Item Continued as 16.82 113 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 114 Supply, installation, testing and commissioning indoor type stainless steel (SS 316) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 316 sheet. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-02 No ( for incomer mains and incomer DG supply) (iii) Onload change over switch 63Amps modular type - 01 nos(Note: Busbar will be connected at changeover output)Outgoing :-(i) MCCB 32 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation, MCB TPN 40Amps - 02 Nos, 3 Phase timer switch 40 Amps- 1 Nos(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)Item Continued as 16.84 115 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 116 SEWAGE TREATMENT PLANT (STP)Design, Supply, Installation, testing & commissioning of PACKAGED Sewage Treatment Plant(NBF Model)of capacity 50,000 Ltrs per Day with FRP Intermediate Cum Treated Water Tank of 20 KL capacity and tertiary treatment based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) complete with Recirculation Pump(Non clog submersible type of capacity 9 m3/Hr, Motor-1HP, Head- 8m) - 01 No,Air Blowers twin lobe type of capacity 3.0 HP - 02 Nos, Filter feed pump (Non clog submersible type of capacity 18.0 m3/Hr, Motor-1 HP, Head- 15 m) - 2 Nos ,Pressure Sand Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosActivated Carbon Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosChlorine Dosing Pump of capacity 0-6 LPH- 1 NosMCC Control Panel ,FRP tank accessories , including all connecting PVC pipes and all others accessories and necessary civil works for installation as per recommendation of OEM.Note:-(a)The minimum life of STP shall be 15 years. A certificate from manufacturer shall be provided by the contractor.(b)The RCC Collection Sump of suitable capacity before STP and necessary pumping arrangement (as required) is deemed to be included in the rate quoted by the contractor.(c)All accessories required to achieve the outlet parameter shall be included in the quoted rate.(d)Necessary arrangements to accomodate the inlet sewer Pipe line as per invert level deemed to be included in the quoted rate.(e)The contractor has to get the design and other parameters for complete sewage system including STP approved from GE before placing of order for procurement 117 COOLING APPLIANCESSupply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 360 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 3 star rated including electric connection complete all as specified and directed. 118 Supply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 310 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 5 star rated including electric connection complete all as specified and directed. 119 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 01 KVA incl electric connection complete all as specified and directed. 120 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 02 KVA incl electric connection complete all as specified and as directed 121 DG SETSupply, installation, testing and commissioning totally enclosed (silent operation with canopy, CPCB-IV+ complaint), static type deidel engine driven, liquied cooled, generating set of 30 KVA, 24KW capacity accommodated with accoustic encloser (at 0.8 lagging P.F), 415V,50Hz, 3 phase system & for 0.85 load factor , base plinth as per manufacturer recommendation, (A) Disel Engine:- Diesel engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 dgree celcius, 50% RH & 1000m above MSL, electronic governer, confroms to BS:5514/ISO 3046, BS 649,IS 10000 with capacity of 10% overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB(A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced,(A1) Air intake system(i) Air intake manifold,(ii) Dry type air cleaner(A2) Exhaust system(i) Dry exhaust manifold with residental silencer and catalytic converter(A3) Cooling system(i) Engine water pump(ii) Radiator with fan(iii) coolant additive concertrate(A4) Lubricant system (i) Oil pan(ii) Engine mounted lube Oil pump (iii) Lube oil filter(A5) Starting System,(i) 12/24 V DC starter motor, voltage regulatorsItem Continued as 16.91 to 16.94 122 (ii) 12/24 V DC alternator for battery charging, (iii) 12/24 V suitable maintenance free battery of suitable capacity(A6) Engine mounted microprocesser based (perferably) instrument panel with digital display for the following:-(i) LED indicating lamps-for Genret running, remote start, shutdown, warning, manual, auto and stop(ii) Data Logs-engine run time and controller on time(iii) Start/Stop switch with key(iv) Indication/Display of for water temp, lub oil pressure, lub oil temp, battery charging,RPM, over speed, low lub oil trip, Engine hours(v) Engine and alternator data - startingf batter voltage, Engine running hours, engine temp, engine oil pressure, alternator voltage, current, KVA, frequency, KWH shall be displayed.(B) protection to Genret, (i) Low lube oil pressure warning/shutdown, (ii) High engine temp warning/shutdown,(iii) Low coolant temp warning, (iv) Sensor failure indication,(v) Low/High battery voltage warning,(vi) weak battery warning, (vii) fail to start shutdown,(viii) Cranking lockout, 123 (ix)High/Low AC voltage shutdown,(x) under/over frequency shutdown,(xi) loss of sencing voltage shutdown.(C) Others(i) AVM Pads, (ii) First fill of lubricating oils(iii) flywheel with housing(iv) Residental silencer,(D) Alternator synchronous alternator copper wounded rated 30 KVA, 415 volts, 1500 RPM,3 phase,50Hz,AC supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 500 MSL, brushless type, self exicited, SPDP encl , contineous duty, voltage regulated through AVR conforming to IS:4722 with class F/H insulation. The sailent feature are as under: (a) Permanent lubricating beraing (b) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (c) permissible unbalancing capability minimum 25% per phase .(E) ACCOUSTIC ENCLOSER FOR DG SET :-S & F accustic enclosers suitable for 30 KVA capacity diesel generator set duly fabricated of channel and CRCA sheet 2 mm of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers / outlet ventilation system etc. complete as per manufacturers instruction with wiring and lighting arrangments duky painted of three coats of delux gloss synthetic enamelled paint over a primer coat or as directed of suitable size all as requried at site and comprising of the following:- (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section, (ii) Structure heavy duty rectangular MS box channel , (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks, 124 (iv) Out side cover : Made out of 2 mm thick ,(v) Accoustic insulation(side & top) sound proffing mineral rock wool slab thickness 100 mm of density 96Kg/m3 confriming to IS 8183 , covered by fire resistant fiber tissue as per manufacturer recommendation. Test report from original manufacturer to be submitted before incorporation in the work authenticity of material, (vi) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel. (F) FOUNDATION :- PCC Foundation M 20 ( or as per manufacturere design ) , 450 mm overall height , 300 mm above floor level and 150 mm below floor level of requried size. The price of foundation of DG Set is included in quoted rate. (G) FUEL TANK:- One no of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load , tank shall be fitted with incanopy as per manufacturers design including the following:- (i) Level indicator to indicate level of diesel in tank,(ii) Drain plug with 2.0 mtrs pipe for drain oil, (iii) fuel strainer, (iv) pipe for fuel,(v) air vent. 125 NOTE:- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted. (b) Tools shall be supplied as per manufacturers instruction and cost therof shall be included in the price quoted. (c) DG Set shall be placved at the site directyed by Engr-in-Charge. (d) Testing of DG Set shall be done as per relivant IS clause or min 10 hour running with 01 hour with no load, 02 hr with 25% load, 02 hrs with 50% load, 02 hrs with 75% load, 02 hrs with 100% load, 01 hr with 110% load. The required Fuel and artificial load/tools, etc to be included in quoted rate. 126 DEMOLITION & DISMANTLINGTaking down carefully old unserviciable DB including of any size/way complete including MCBs for keeping in safe custody or for taking credit all as directed. 127 Taking down carefully old unserviciable service cable of any size for keeping in safe custody or for taking credit all as directed. 128 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 129 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 130 Taking down carefully old unserviciable sluice valve 100 mm for keeping in safe custody or for taking credit all as directed. 131 Taking down carefully old unserviciable sluice valve 150 mm for keeping in safe custody or for taking credit all as directed. 132 Taking down carefully old unserviciable gate valve 25 mm for keeping in safe custody or for taking credit all as directed.
Contract Date: Feb 12, 2026 Contract Value : 39.08 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
32.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
33.
Defence #9519801 AOC
Tender For Improvement To Lt Network Panels Along With Associated Earthing And Allied Works At Af Stn Bagdogra; 1 Demolition and removal of existing brick tiles or terracing tiles, single layer on roofsincluding wire brushing and cleaning top surface of cement concrete, including flashings and junction of parapets, etc and removing debris/rubbish materials out side MoD land, complete all as secified and as directed. 2 Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges,complete all as specified and as directed 3 Dismantling plain or corrugated steel sheeting any gauge thickness inclding Nainital or similar pattern roof coverings, complete all as specified and as directed 4 Dismantling of wrought iron or mild steel work of any description or otherwise provided, complete all as specified and as directed. 5 Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed. 6 Demolition of (Un reinforced) Cement Concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. 7 Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) andrubbish off the premises complete all as specified and directed. 8 Taking down chowkhats or frame with shutters without taking of shutters from frames not exc. 1.5 Sqm each inclding making good disturbed portion, complete all as specified and directed. 9 Taking down chowkhats or frame with shutters without taking off shutters from frames exc 1.5 Sqm but not exc 4.00 sqmeach including making good disturbed portion, complete all as specified and directed. 10 Demolition of brickwork built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as per specified and directed. 11 Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed. 12 Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres, complete all as specified and as directed. 13 Taking down 15mm dia bore steel tubing and connections including cleaning for re-fixing or removal from site, complete all as specified and directed. 14 Taking down 20mm dia bore steel tubing and connections including cleaning for re-fixing or removal from site, complete all as specified and directed. 15 Dismantling of Rolling Shutter including all accessories etc., complete all as specified and directed. 16 Demolition and breaking updrain pipes (Salt glazed stone ware orconcrete) of 150mm dia (Internal), set in cement mortar, including taking out from trenches if required with demolition of concrete bed and removing from the site, complete all as specified and as directed. 17 Dismantling and breaking updrain pipes (Salt glazed stone ware orconcrete) of 100mm dia (Internal), set in cement mortar, including taking out from trenches if required with demolition of concrete bed and removing from the site, complete all as specified and as directed. 18 Taking out of MCBs for existing DBs and refixing to the same in new 4 way TPN DBs, complete all as specified and as directed. 19 M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate, rough finished as in levelling course on roof, complete all as specified and directed. 20 M&L for preparation of concrete surface by cleaning of roof surfaces with wire brushes and applying 15 mm thick plaster in CM (1:4) mixed with water proofing compound as per manufacturers instruction, on roof slab, finished even and smooth without using extra cement, complete all as specified and directed. Notes : WPC shall be measured and paid seperately. 21 M&L for water proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS -3384 @0.30 litre/Sqm, by lying actetic polypropylene (APP) modified membrane prefabricated, reinforced with non-woven polyester, of 3.0 Kg/Sqm(minimum) 3mm thick with minimum 100mm side overlaps and minimum 150mm end laps and applying one coat of bituminious aluminium paint over APP membrane, complete all as specified and directed.. 22 M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated/semi corrugated/Trapezoid steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed 23 M&L for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed 24 S&F steel workin tubular trusses(Square/ rectangular) including special shaped washer etc. complete using ERW or induction butt welded tubes comfirming to IS-1161- 1998grade St-240, complete all as specified and as directed. 25 S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay) heavy for large gates, hook and pintle hinges large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. 26 M&L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of redoxide primer, complete all as specified and as directed 27 M&L for preparation of old painted steel / iron surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed. 28 S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm longNon asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws, complete all as specified and directed. 29 M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded aggregate) as in plinth protection/ path/ paving etc. laid in panels, finishing the top surface even and smooth without using extra cement, complete all as specified and directed. 30 Roughening surfaces of old concrete floor by picking, scrubing, sweeping clean and washing down with water to remove dust, etc.complete all as specified and directed. 31 M&L for machine cut kota stone slab 20-25mm thick as in flooring laid & jointed with cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing including 20mm thick screed bed in CM 1:4, complete all as specified and directed. 32 M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over on vertical surface of wall and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 10mm thick rendering in CM (1:4), complete all as specified and directed. 33 M&L for Vitrified Ceramic tiles light shade 8-10 mm thick, area of each tiles not exc 0.36 Sqm, in floors, set and jointed in neat cement slurry and pointed in white or coloured cement including 15mm thick screed bed in CM 1:6complete all as specified and directed. 34 M&L for Vitrified Ceramic tiles light shade 8-10 mm thick, area of each tiles not exc 0.36 Sqm, in skriting/vertical surface, set and jointed in neat cement slurry and pointed in white or coloured cement including 10mm thick rendering in CM 1:4, complete all as specified and directed. 35 M&L for non skid coloured ceramic floor tiles of size exc. 0.11 but n.exc.0.18 sqm each, 7-8 mm thick laid in floor set, jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6, complete all as specified and directed. 36 M&L for colour glazed ceramic wall tiles of size 450x300x7mm thick on vertical surfaces on vertical surface of wall, set and jointed in neat cement slurry and pointed in white or coloured cement to match including rendering 10mm thick in CM (1:4)complete all as specified and directed. 37 S&F powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed. 38 S&F 4 mm thick one side frosted sheet glass ordinary quality and glazing in square n.exc 0.5sqm in each pane fixed withneoprene rubber gasket in aluminium frame, complete all as specified and directed. 39 S&F powder coated aluminium (minimum thickness of powder coating 50 micron) door shutters, aluminium section weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, powder coated aluminium fittings such as handles - 02 Nos, 100mm long hinges - 03 Nos, sliding bolt - 01 Nos, tower bolt - 02 Nos in each door, powder coated aluminium snap beading and rubber gasket, screws etc., complete all as specified and directed. Note:Glass shall be measured seprately. 40 M&L for 5.5 mm thick sheet glass ordinary quality and glazingeach pane fixed with neopunerubber gasket in aluminium frame work, complete all as specified and directed. 41 S&F Solid PVCdoor frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per specification & drawings, complete all as specified and directed. 42 S&F factory made solid PVC moulded door shutters with particle board core 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face ,supplying & fixing in frame at site as per specification & drawing, complete all as specified and as directed. 43 S&F 1.25 mm thick pressed steel frame of size 105X 60 mm for door with one ore more rebate includings necessary fixing lugs, stainless steel hinges, locks strike plate etc., complete all as specified and as directed. 44 M&L for PCC 1:3:6 type C1 (using 20 mm graded aggregate) for holdfast blocks, complete all as specified and as directed. 45 S&F factory made 35mm thickflush shutters solid core construction with block board and plywood face pannel commercial type on both faces, complete all as specified and as directed. 46 S&F for 100mm long mild steel (cold rolled) butt hinges, medium weight, complete all as specified and directed. 47 S&F 150mm long extruded aluminium alloy handles, fabricated type anodised, complete all as specified and directed. 48 S&F 300 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing with accessories, complete all as specified and directed. 49 S&F 150mm long aluminium anodised barrel tower bolt ofextruded section, complete all as specified and directed. 50 S&F aluminium (extruded section body) door closer hydraulically regulated, designation No 3, universal type, suitablefor door shutters 851 mm to 1000 mm in width and of weight between 61 to 80 kg and fixed, complete all as specified and directed. 51 M&L for welded steel wire fabric weight not exceeding 4 kg per square metre supplied and fixed complete to wood or steel members, complete all as per specified and directed. 52 M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, complete all as specifed and directed. 53 M&L for 15 mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on wall, complete all as specified and directed 54 M&L for preparation of new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over 1.5mm thick wall care putty, complete all as specified and directed. 55 M&L for 15 mm thick rendering in CM (1:4) onfair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed. 56 M&L for 5mm thick rendering in cement mortar 1:3 on fair faces of concrete surfaces without using extra cement on ceiling, complete all as specified and directed 57 M&L for preparation of new plaster surface of ceiling and applying two coats of white wash, complete all as specified and directed. 58 M&L for preparation of newly plastered surfaces of wall and applying two coats of Weather Proof Exterior Emulsion paintover a coat of suitable primer on walls, complete all as specified and directed. 59 M&L for complete removal of existing treatmentand applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over prepared surfaces, complete all as specified and directed. 60 S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I, complete all as specified and directed. 61 S&F ball valve 20mm high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, complete all as specified and directed. 62 S & F in repair 20mm bore gate valves with iron wheels head screwed both ends for iron pipe and fixed, complete all as specified and directed. 63 M&L for cutting chasing pinning in making good to facing where required for concealed water tubing etc n. exc 10 cm girth in brick wall, complete all as specified and directed. 64 S&F 15mm bore unplasticised PVC pipes of pressure rating 10 kgf/Sq cm fixed to wall or ceiling or laid in floors including fittings etc., complete all as specified and directed. 65 S&F 20mm bore unplasticised PVC pipes of pressure rating 10 kgf/Sq cm fixed to wall or ceiling or laid in floors including fittings etc., complete all as specified and directed. 66 S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specifed and directed. 67 S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed 68 S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specifed and directed. 69 S&F in repair 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. 70 S&F in repair PVC (SWR) vent cowl 110mm bore, complete all as specifed and directed. 71 S&F in repair 110 mm bore PVC (SWR) bends any radius, complete all as specifed and directed. 72 S&F in repair PVC (SWR) Bend radius any radius 75mm bore, complete all as specifed and directed. 73 S&F in repair PVC (SWR) junction single, (single T) equal or unequal 110mm bore, complete all as specified and as directed 74 S&F in repair PVC (SWR) junction single, (single T) equal or unequal 75 mm bore, complete all as specified and as directed 75 S&F in repair PVC (SWR) floor trap plain with gratinghaving dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified & as directed. 76 S&F in repairs sheet glass shelf glass assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long fixed with chromium plated brass screws, complete all as specified and as directed 77 S&F in repairs CP soap dish size 160X160X90mm fixed to wall with screw complete all as specified and directed. 78 S&F in repairs 20 mm dia aluminium anodised tubular towel rail, D type, 60 cm long between flanges fixed with brass screws complete all as specified and directed. 79 S&F in repairs 15 mm bore chromium plated fancy type angle valve with elegant knob screwed down high pressure, with crutch or butterfly handle screwed for iron pipe or for unions, complete all as specified and directed. 80 S&F in repairs 15 mm bore chromium plated fancy type bib taps with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. 81 S&F in repairs 15 mm bore chromium plated fancy type pillar tap for WHBs with capstan heads, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed, complete all as specified and directed. 82 S&F in repairs, PVC connection 15mm dia and 450 mm long with 2 Nos PTMT nuts with washers, complete all as specified and directed. 83 S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic actiontype with inlet ball valve and float, handle with & including bracket andPVC flush pipe 32 mm borecomplete all as specified. 84 S&F in repairs 600 mm x 450 mmsize beveled edge mirror of selected quality glass, 5.50 mm thick, mounted on 6mm thick AC pain buildingboard or commercial plywood and fixed to wall with wooden plugs and chromium plated brass screws & cup washers complete all as specified and as directed. 85 S&F in repairs vitreous china, Sqatting pan, Orissa Pattern, size 580 mm x 440 mm white, withintegral foot rests (excluding flushing cistern and flush pipe) and including 100mm bore ‘P’ or ‘S’ trapand provision of cement concrete bedding and connected to existing flush pipe, complete all as specified and as directed. 86 S&F in repair vitreous china wash hand basin (flat back) of size 550x400mmincluding one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector,including cutting for and pinning in ends of brackets complete all as specified and as directed. 87 Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth for foundation or for taking out or laying pipe linesetc and getting out in soft/loose soil, complete all as specified and as directed. 88 S&F in repair 25 mm outer dia medium weight pipe made out of stainless steel 304 grade, includingdecorative ornamental knobs at both ends and one set of ornamental decorative Stainless steel clamps tofixed towalls, complete all as specified. 89 S&F stainless steel 304 grade clamps with ends/stops etc.including other accessoriesfor fixingarrangements of25mm mm dia curtain rodto wall, complete all as specified and as directed. 90 S&F Stainless steel 304 grade ornamental knobs for side of curtain rods includingfixingarrangements, complete all as specified and as directed. 91 S&F powder coated aluminium sliding window shutters 25 mm thick with frames (consisting of two nos glazed shutters and one no gauze shutter)3 track sliding shutters, duly fitted with neoprene beading glazing clip, locking device, heat absorbing glass 5 mm nominal thickness in glazed shutters, stainless steel wiremesh of 0.254mm nominal dia of wire and 0.95mm average width of aperature in gauzed shutter, complete all as specified and as directed. 92 S&F fabricatedpowder coated anodized aluminium grill of size 75x75 mm, using 6mm dia bars fixed to outer portion of chowkhat using U/V section runners, complete all as specified and as directed 93 M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel painting over a coat of pink primer, complete all as specified and as directed. 94 M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 95 S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5sqm in each pane, complete all as specified and as directed. 96 M&L for complete removal of existing treatment of surfaces and applying two coats of oil bound distemper over 1.5mm thick wall putty, complete all as specified and directed. 97 S&F Steel rolling shutters, thickness of laths 1.25mm, with ball bearing, as specified including top cover, anchoring rod, hasp and staple, 2 lever locks and one shop coat of primer; erected in position complete push but gear operated type with bevel gear box and crank handle, complete all as specified and directed. 98 S&F Ball bearing for rolling shutters, complete all as specified and directed. 99 Supply only intergral water proofing compound, complete all as specified and directed. 100 M&L for cement concrete 1:4:8type D-2(using 40mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. 101 S&F Mild steel framed work such as framed guard bar conforming to Fe 290,Gde-E-165, complete all as specified and directed. 102 M&L for surface dressing n. exc 15 cm deep in any type of soil, complete all as specified and directed. 103 M&L for hardcore of broken stone or aggregate of gauge n. exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. 104 M&L for75 mm thick PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in sub base etc., complete all as specified and as directed. 105 M&L for designed, pre painted coloured chequered cement concrete tiles of 300x300x25mm size set, jointed & pointed in neat cement slurry with grey cement and pigments , laid over 20mm thick screed bed in CM 1:6 finished with pigments match the shade of tiles, complete all as specifeid and directed. 106 M&L for sand cushioning to receive interlocking tiles including spreading, levelling in layers, complete all as specifeid and directed. 107 M&L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade with grey cement andpigment, complete all as specifeid and directed. 108 M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping/kerb stone etc., complete all as specified and as directed. 109 M&L for excavating in post holes (or similar holes) each n.exc 0.5Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25CM, in soft and loose soil, complete all as specified and as directed. 110 M&L for cement concrete 1:2:4 type B-2 (using 40mm graded aggregate) as in foundations, filling and mass concrete in post, pillars, complete all as specified and as directed. 111 Supply only 4mm dia Chain link MS galvanised fencing, weight not exceeding 4kg per sqm, complete all as specified and directed.Note :- Weight of chainlink fencing shall be ascertained by BOO. 112 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified and directed. 113 M&L for mild steel framed work as in doors, gates of angle iron, flat ironor other section with gusset plates, rails, braces, hold fast, pin and pintol hinges, sliding bolt etc. complete, drilled for fixing of steel sheeting or other covering doors etc. to beprepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (exclusive of steel sheeting or other covering, running rails and guides ) and hanging; also fastening and fixing, complete all as specified and as directed. 114 S&F mild steel works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to e-290 Gde E-165,complete all as specified and as directed. 115 Supply only mild steel round bar 10 mm dia and over for tying chain link fencingetc., complete all as specified and directed. 116 Supply screw bolts (machine made) with hexagonal or square head at one end and rounded the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5 cm but n.exc 10 cm and dia of shank 11 to 15mm and fixed in position, complete all as specified and directed. 117 M&L for 0.80mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and directed. 118 M&L for preparation of new or untreated steel and iron surfaces of any description not exc.10 cm in width or girth and applying two coatsof synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. 119 S&F in repairs, Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and as directed 120 M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregates as in concrete bed to drain pipes including packing under and haunching against the side of pipes,laid, jointed and tested for 150mm bore pipe, complete all as specified and as directed 121 M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregates as in concrete bed to drain pipes including packing under and haunching against the side of pipes,laid, jointed and tested for 100mm bore pipe, complete all as specified and as directed 122 M&L for salt glazed stone ware (SGSW) drain pipe, 150mm dia (Internal), grade ‘A’ laid in trenches and jointed including testing, complete all as specified and as directed. 123 M&L for salt glazed stone ware (SGSW) drain pipe, 100mm dia (Internal), grade ‘A’ laid in trenches and jointed including testing, complete all as specified and as directed. 124 Removing excavated materials (soil) to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed. 125 Returning, filling in,soft/loose soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed. 126 M&L for soakage well including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size of 1.80m dia and 3.00 m deep,complete all as specified and as directed. 127 M&L for 5500 ltr capacity LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc.,complete all as specified and as directed. 128 Taking down/up XLPE cable of 10 sqmm to 16 Sqmm 2 core complete with bricks & GI pipe complete all as specified and directed. 129 M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts Earthed, grade cross sectional area 16 Sqmm 4 Core, complete all as specified and as directed. 130 M & L for Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the galvanised iron strip 32 x 6 mm, by means nut bolt, nuts, check nuts and washer of the GI Earth strip protected by provision of GI light grade pipe 40 mm, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion, complete all as specified and as directed.. 131 Supply, installation, testing and commissioning of 11 KV Compact Substation (CSS) out door type plinth mounted, enclosure having construction of Powder Coated/ Galvanised sheet steel of 1.6 mm thickness for non load bearing and 2.0 mm for load bearing partition sheets, and door with HRCA 4.00 mm base frame. The enclosure shall have IP54 degree of protection for HT< switchgear components and IP34 degree of protection for Transformer component. Each components will be provide with corrosion resistance and all side openable hinged door and lock and key arrangements. Heavy lifting lugs with all equipments load. Necessary danger plates outside of the CSS. The compartment illumination lamp with door operated switch shall be provided for all the compartment including necessary foundation and earth work as per manufacturers recommendation and as per the site conditions (drawing and specifications of the foundation recommended by the manufacturer to be approved by GE before commencement of thework, thequoted ratesare deemedto beinclusive ofthe same). The CSSis comprising of the followings :- 132 (Srl Item No. 131.00 Contd...)HT SWITCHGEAR:-11 KV, Non -extensible 2 WAY (1 LBS+ 1 VCB) Non- Extensable RMU compact switchgear consisting of 1 nos direct Module (LBS) and 1 No 630 Amps VCB fixed operated Manual and spring charging & closing, electrolyte grade copper busbar 11 KV/630 Amps VCB in SF6 insulated stainless steel enclosure with series trip, self-powered microprocessors numerical over current and earth fault relay protection, HT cable/Bus Bar , and one metering module with necessary CTs and PT and digital panel mounted multifunction meter with class 1.0 accuracy, comprising the following:- (Complete unit is to be installed inside CSS, protection accessories , Enclosure : Metal Clad, IP-54 Protection. Protection Relay: Self Powered Alfa numeric LCD display type. Internal arc tested for 1 sec, Fully compartmentalized sheet steel enclosure with automatic safety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows: -Rated Voltage - 12 KV , Rated Frequency - 50 Hz., Rated continuous current rating - 630 Amps. , Rupturing capacity of VCB --350 MVA, Rated Interrupting Current - 21 KA. , Rated making current for VCBs- 52 KA. , Rated making current for Isolators - 62 KA. , Rated short time current for 3 sec - 21 KA , Operating duty - O-3min-CO -3min.-CO , Power frequency withstand voltage - 28 KV , Impulse withstand voltage - 75 KV , Busbar rating - 120% of continuous current., Operation: Spring closing mechanism - DC motor operated with 24-volt supply, Breaker Closing - Manual & Electrical through TNC switch., Shunt Trip coil - 24 V DC, Safety Interlock Locking faciality - Required., Breaker panel indication - ON (Red) OFF (Green)Accessories: 1 No. Self Powered Relay, Mechanical counter, Space Heater with Thermostat, Fuse and ON/OFF Switch, Aux relays for remote trip/indication for PC interface etc, cubicle illumination lamp LED 5 watt retrofit type 230 V AC, T-N Switch, Anti pumping contractor etc. In addition to the above all standard fittings to be provided as per IS normsMimic Diagram: An operating mimic diagram shall be provided on the front side of each cubicle.Note: - Circuit breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM. The installations, calibration and testing of SF-6 circuit breakers will be conducted in the presence of authorised representative of OEM by the Contractor. Power pack of 230V AC, 24DC of minimum 30min backup for RMU is included in the item rate and rating of battery as described by OEM. 133 (Srl Item No. 131.00 Contd...) 11KV/0.433KV OIL TYPE TRANSFORMER OF 500KVAOil filled Type 3 phase, 50 Hz, Dyn11, ONAN type Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and Busduct inLV side complete with all accessories like buchholz relay, Oil temperature indication, windingtemperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as EEL-2 confirming to IS-1180 Part-I:2014 as per latest 4th amendment in Mar 2021 & 100%loadi/c as per specification below complete in all respects as required at site including first filling of transformer oil. Design ambient to be considered as 50 Deg C. All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only. Heat Run Test is the mandotary test for each Transformer Standard: The equipment shall confirm to the latest edition of applicable standards as follows. In case ofconflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines. oil Insulation class : K class. It should also exhibit safety against fire hazards 134 (Srl Item No. 131.00 Contd...)CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeabilityPRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noiseand vibrations. Followings should be Mandatory for any manufacturer: -a. Transformer shall be of BOLTLESS core design 135 (Srl Item No. 131.00 Contd...)LT PanelLT panel- Separate compartment for LT network inside the CSS made with 2.0mm CRCA sheet with necessary angle iron frame, dust and vermin proof, with separate openable door for LT side with necessary locking arrangement, opening for LT AL Busbar/cable entry, opening for natural air ventilation/cooling, necessary suitable range of panel mounting Multifunction Meter (6400NG), CTs etc as required with ACB 4 pole Icu=Ics=Icw(1sec) = 50kA @ 440V AC 50 Hz of breaking capacity 50KA, with EDO type, Microprocessor based overcurrent, short-circuit and earth fault release of capacity 800 Amps -01 Nos ( Main incomer of LT) and including the followings LT distribution ( i.e. LT out going).LT Outgoing: -(i) MCCB 4 pole 415-volt 50 Hz of breaking capacity 36KA, 250 Amps, Ics=100% Icu TMD overload and short circuit protection with Encapsulated double break roto technique ensures outstanding current limiting capability - 3 Nos.(ii) MCCB 4 pole 415-volt 50 Hz of breaking capacity 36KA, 200 Amps, Ics=100% Icu TMD overload and short circuit protection with Encapsulated double break roto technique ensures outstanding current limiting capability - 3 Nos.(iii) MCCB 4 pole 415-volt 50 Hz of breaking capacity 36KA, 160 Amps, Ics=100% Icu TMD overload and short circuit protection with Encapsulated double break roto technique ensures outstanding current limiting capability - 2 Nos.(iv) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. Note :- The civil work for foundation of CSS shall deemed to be included in quoted rates. 136 M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 Sqmm 3 Core complete all as specified and as directed. 137 M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmmcomplete all as specified and as directed. 138 Disconnecting and shifting of transformer of capacity 200 to 315 KVA form one sub station to another sub station by mechanically and reconnect the same, complete all as specified and directed 139 Supply,installation, commissioningandtesting complete with all accessories of transformer of 33 KV capacity 5 MVA step down, outdoor floor mounted, double copper wound,3 Phase, 50 Hz, AC,Oilimmersed, ONAN confirming to IS-2026 and IEC62770 including cooling fans, external cooling tubes/radiator cores type havingvoltage ratio 33000/11000 volts (corresponding to principal tapping ) winding delta connecting on Primary side (HV Side) and star connected on secondary side (LV side) in accordance with vector symbol Dyn11 (vector Group) with neutral brought out on LV side and looping on HV side for contact output so as to alter/vary secondary voltage by (+) 5 to (-) 15% in equal steps of 1.25% to be changed by means of (OLTC) on load Tap Changer with RTCC and AVR. Supply ,installation of RTCC panel with AVR and marshaling box . Transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability PRIME GRADE, CRGO with m4 grade or Better, Perfectly insulated and clamped to minimize noise and vibrations. 140 (Srl Item No. 139.00 Contd...)The transformer shall confirm to the latest edition of applicable standard as follows :-(i) IS-2026, for tests and tolerance of guarnteed Particulars. (ii) IS-3639 for Fitting and accessories. (iii) IS2099 for Bushing >1000V. (iii) IS-7421 for Bushing <1000 V (v) IS-1271 for Electrical insulation classified by Thermal stability. (a) Winding (iv) HV Winding -Layer/disc winding(i) LV Winding-Helical/Disc widing(b) Insulation Level (i) HV-170 (ii) LV-70 (c) Insulation level (Power frequency with Stand KVrms)(i) HV 70 (ii) LV-28 141 (Srl Item No. 139.00 Contd...)(d) Tapping Range -(+)5% to (-) 15% @1.25%(e) Tape Changer Type -On load Tap Changer +RTCC+AVR. (f) Temperature Rise (Oil/Winding) -50/55 Degree Centigrade(g) Hot spot temperature over a maximum yearly weight average ambient temp of 32 Degree Centigrade-98 Degree Centigrade(h) Termination HV/LV-Cable Box(j) Short Circuit thermal withstand time-02 seconds (k) %impedance at 75 °C clurrent and frequency (Subject to IS Tolrance) at 5 MVA base % 7.35(l) Load loss at rated current and 75 degree C (KW) (subject to IS Tolerance )at 5 MVA base -70(m) % load at which Max Efficency occurs %-33.81(n) Regulation at full load 0.8 PF%.-5.75The transformer should have following fitting and accessories :-(a) Cable Boxes on 11 KV secondary side for single core XLPE cable 3 Core 185 Sqmm(b) Outdoor 33 KV bushing insulator for connection through openconductor with sleeves.(c)Oil conservator with filling hole and cape drain valve and oil level guage.(d) Dehydrating breather wth connecting pipe first fill of dehydrating agent and oil seal.(e) Explosion relief vent mounted on tank with double diaphragm and equilliser pipe connection to conservator air space (Pressure release device)(f) Air relief plug.(g) Shut off valve between the conservator and buchholz relay.(h) Drain valve with threaded adopter. 142 (Srl Item No. 139.00 Contd...)(j) Filter valve with threaded adopter (Top and bottom).(k) Wheels (l) Rating plate and terminals marking plate.(m) Extra bushing for neutral out side the LV Side (n) Hand hole sufficient size to assess the interior of the tank.(o) First filling of the transformer oil.(p) Cover Lifting eyes.(q)Double float Buchholz relay with trip and alarm contacts.(r) 150mm dial type thermometer for winding temperature indicator having range0-12 centigrade vapor pressure type with maximum reading pointer/Max temperature indicator and resetting devicewith alarm/trip contact and additional contact for switching on the cooling fan.(s) Dial type thermometer for oiltemperature indicator with 02 sets of contacts for alarm and triphaving range 0-12 centigrade vapor pressure type with maximum reading pointer/Max temperature indicator and resetting devicewith alaram/trip contact .(t) Shut off valve between cooling tubes and tank.(u) Pressure Release Valve (PRV) with one set of trip contact.(v) Magnetic Oil gauage (MOLG) with one set of trip contact.(w) Earthing terminal for connecting earthing leadNOTE:-(i) The oil temperature and winding temperature guages shall be housed in a marshaling box made up of MS sheet as per manufacturer recommendations with hinged door and having glass front side of the box and provision for entry of cables and compression glands.(ii) The civil work for foundation of CSS deemed to be included in quoted rates.(iii) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. 143 Supplying , transporting, erectioning, testing and commissiong of 33 KV, 350MVA, 630 A, 50Hzvoltage class outdoor type Vaccum Circuit Breaker for use on system voltage 33 KV. The circuit breaker and accessories shall conform to IEC-62271-100 or IS 13118 and other relevant IEC/IS standard. The circuit breaker shall be complete with terminal connection, operating mechanism, control cabinets, piping, interpole cable accessories like gland, terminal block, lugs, 02 Nos level pressure switch scale. necessary steel support structure for CB and control cabinetThe circuit breaker shall be required to performs as per technical parameters given below:- 144 (Srl Item No. 143.00 Contd...)(a) Installation - Outdoor, 3-phase, Live-Tank, Porcelain Clad, Switchyard Breaker(b) Rated Voltage - 36 KV(c) Rated Current - 630A or higher(d) Power frequency with stand voltage (KV rms)- 70 KV(e) 12/50 microsecond lighting impuls with stand voltage (KV Peak)-170 kVp(f) Rated short circuit current breaking capacity (3 Sec ) at rated voltage specified 31.5 KA(g) Control Voltage incl. trip/close coil - 30V DC (h) Spring Charging Voltage - 230VAC(j) Symmetrical interrupting capacity (KA/RMS) 31.5 KA for 3 sec(k) Rated short circuit Making Current (KAP)-80A(l)Out of phase breaking capacity (KA rms) as per IEC(m) Rated operating duty as per IEC(o) Temp rise over the design ambient temperature -As per IEC 62271-100(n)Operating Mechanism -Spring (o) Creepage distance as per IEC-900mm (p) No of trip/close coil 30 V DC-02 Nos(q) Tripping system - 30 V DCNote:-(i) Cost of supply and fix of Outdoor type Terminal Kiosk (TK) havingterminals/disconnecting-links for termination of CT/PT wiring including PT secondary fuses complete all as required at site are deemed to be included in the quoted rate.(ii) Cost of construction of foundation including construction material and necessary earth work as per manufacturer design for breaker TK complete all as required at site are deemed to be included in the quoted rate. 145 (Srl Item No. 143.00 Contd...)(2) 33KV control & relay panel indoor type for Vaccum Circuit Breaker.The panel shall be with back access double door arrangement, dust and vermin proof , IP -4X class protection and made 2mm , CRCA MS sheet powder coated finsh over one coat of red oxide primer both side operating type, including internal wiring using 1.1kV FRLS insulated multistrand cable (2.5sqmm for CT/PT and control circuit, numbered and colour coded as per IS-5578/1984 having suitable entry for cable consisting of the following:-(A) Main, Numerical Protection Relay with LCD displaying mimic bay for ON/OFF control and monitoring of feeder current. Built in as of 11 KV VCB panel relay disturbance recorderand event logger to monitor the Sequence of Events (SoE) using upto 800 event codes. The relay shall be communicable SCADA system.(i) Over current and earth fault protection with minimum pickup at low set of 5% and 1% respectively(ii) Transient/intermittent earth fault protection(iii) Phase discontinuity protection(B) Flush mounted auxillary relays for:-(i) Trip Circuit Supervision(ii) Master Trip(iii) Fuse fail (PT) supervision operated (iv) DC supervision scheme(v) Overvoltage/ undervoltagereay within max value settings with reset(C) Metering(i) Metering Equipment incl. 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-Vector-Meter (Acc.Cl.0.5). (ii) 01no. Multi-Function-Meter (Acc.Cl.0.5) shall be provided with LCD display for measuring current, voltage, power, power-factor and energy-parameters, Total Harmonic Distortion and Max. Demand Indication, same shall be communicable on ModBus via RS485 port. 146 (Srl Item No. 143.00 Contd...)(D) Indicating Lamp. (i) Bus-01 Isolator ON/OFF. (ii) Bus-02 Isolator ON/OFF. (iii) Line Isolator ON/OFF/EARTH(iv) CB auto trip. (v) CB ON. (vi) CB OFF. ii) CB Spring Charge. iii) Trip circuit healthy. x) DC Available LED with push-button(x) R-Y-B Phase LED Indication(E) Semaphore indicator. (i) Circuit Breaker ON, OFF. (ii) Bus-01 Isolator ON, OFF. (iii) Bus-02 Isolator ON, OFF. (iv) Line Isolator ON, OFF, EARTH(F) Control switches/Push Buttons(i) Trip-Neutral-Close Switch for Circuit Breaker Control - 01no. (ii) MCB for AC isolation - 01no. (iii) MCB for DC isolation - 01no.(iv) Heater switch with thermostat - 01no. (v) 3-pin socket with ON/OFF switch - 01no.(vi) CFL Lamp with ON/OFF switch - 01no.(G) 08-Window Annunciator with hooter and Mute, Acknowledge, Reset and Test buttons for:- (i) OC Trip Alarm(ii) EF Trip Alarm (iii) Line Differential Trip Alarm (iv) PT Fuse Failure Alarm. (v) Trip Circuit Failure. (vi) Spare.(H) Test Terminal Block for CT(j) Thecost of construction of foundation as per manufacturer design,necessary PCC work, demolition of floors/walls of substation including foundation frame (supplied by OEM) for control panel as required at site are deemed to be included in the quoted rate.(k) Power pack of 230V AC, 24 DC of minimum 30min backup.(l) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. 147 Supply and installation of 33 KV, single phase, out door oil cooled CT of ratio 400/5-5 Amp, class 1.0 / 5P10, burden 15 VA ,complete all as specified and directed 148 Supply and installation of 33 KV single phase out door oil cooled PT of ratio 33 KV/rt3/110 V/rt3/110V/rt3, Class 0.5-3, Burden 50 VA – 50 VA, complete all as specified and directed 149 Supply and fixing lightning arrestor HT 33 KV, 10 KA,station class, complete all as specified and directed. 150 Supply and fixing HT 33 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators and with earth switch upto 400 Amps, complete all as specified and directed. 151 Supply ,install ,testing and commissioning of outdoor type floor mounted metal clad 11 kV ,VCBhaving rupturing capacity 350 MVA of rating upto 630 Amp. with 1 way - ICOG, totally enclosed fully interlocked draw out type breaker as per IEC 62271-100 & IEC 62271-200, as amended upto date and additional specification, having capacities as mentioned below, single break, trip free mechanism, manual/spring charging and auto/ manually closing breaker suitable for use on 11 KV, 3 phase, 50Hz AC supply with short circuit fault level of 25 kA for 0.1 sec , Panel shall be full internal arc tested i.e. in all three chambers at 25 kA for 0.1 sec for safety purpose (AFLR). complete with self contained, fully interlocked, breaker featured with mechanical on/off indicator with hand trip device, spring release coil, S/T coil and auxiliary switch of 6 NO+ 6 NC and equipped with following switch gears and accessories including in the connection suitable for upto 3C x 1R X 185 sqmm XLPE 11 KV cable (cable entry from Bottom side) end termination. Panel shall have micro processor based numerical relay with O/L, S/C,instantaneous, E/F. Arc flash protection to operate on Current and light for faster tripping in Cable, Bus Bar and Breaker Chembar. Panel shall have made with Aluzinc frame.The HT panel shall be compatible for applications and shall be complete with compatible hardwares. And all meters should be provided with RS 485 port with modbus. Endurance Class of VCB should be E2-M2-C2 and Number of fault breaking should be 10,000 Nos for reliability & Ease in operation. Rack-in & Rack-Out operation should be floor rolling design Make of Vacuum interrupter, circuit breaker, Panel, relays & meters shall be same. There must be a viewing window on VCB chamber door and same must be as per Internal arc test report. The basic insulation level of entire panel shall be 28 KV(RMS) / 70KV(Peak). For easy access of document like catalogue, O&M and drawing there should be QR code, pre- configured on the product Approved.Incommer - 1 Nos1 No. Vacuum Circuit Breaker - 630 A, 11 KV, 50 Hz, 3 phase, 25 kA for 0.1 sec, Breaker comes as completely sealed pole assembly to ensure long term performance Breaker control switch. 152 (Srl Item No. 151.00 Contd...)03 No. 11 KV/√3/110V/√3/110V/√3 class 1.0/3 P 50VA accuracy with 1 No. voltmeter (0- 36KV), digital type, selector switch for voltmeter and MCB for HT metering upt 11KV on incomer.1 No. 0-800A digital Ammeter with selector switch. 1 No. Trivector / MFM meter, communicable RS 485 port for MODBUS TCP- IP protocol 1 No. micro processor based with Modbus TCP-IP communication protocol numerical relay 1 set of dual core dual ratio 3CTs 125- 75/1A/1A of suitable burden and accuracy class 0.5 for metering and class 5P10 for protection.Master Trip circuit relay.Restricated earth fault protection shall be part of main protection relay. Over current IDMT & Instantaneous numerical relay with communication port suitable for Modbus TCP-IP . For the same one core of PS class to be added in CT Alarm annunciator for all i/c, tie breaker, buscoupler and outgoing HT VCBwith 12 windows with ACK, rest, test push button for transformer faults and electrical faults.Suitable space for termination upto 1No. 3 C x 185 sqmm XLPE cable outgoing feeder.1 Panel HT Board complete as required, as per single line diagram and specification. Indication Lamp shall be as required Wireless thermal sensors on Bus Bar Joints and Cable termination should be provided along with wireless Climatic sensors Suitable arrangment to capture the data and through PLC and gateway should be visible on HMI of panel, and these date should be possible to view on BMS/SCADA (if availble) Cable Box to be provided for ICOG Panel. Power pack of 230V AC 24 DC of minimum 30 minutes backup.Note :- (i) PCC platform/plinth shall be constructed as per OEM recommandation and rate for the same shall deemed to be included in quoted rates. (ii) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. 153 Supply, install, testing and commissioning of 11 KV, 3ph, 50Hz, indoor type, totally enclosed metal clad switch gear, floor mounted, complete with Vacuum circuit breaker having rupturing capacity 350 MVA, 630amp, insulation level-12KV/28KV/ 75KVP, SC rating-26.3 KA for 3 Sec. IEC Ref- 62271-200 or latest updated, overload and earth fault protection, ampmeter, voltmeter and of current rating not less than 800 Amps including necessary connection with existing cables including following details specification all as specified and directed.:-(i) (a)Digital numerical relays for earth fault, over current protection and models as directed by OEM .(b) high speed trip relays.(c ) Closing coil, trip coils of 110V, DC(d) VCB will be horizontal break and horizontal draw out type.(e) VCB panel shall be suitable for local/remote control.(f) The panel will be provided with LED indicators as specified by OEM(g) Spring charging motor 0f 230V, AC(h) Auxiliary relay for transformer protection haaving buchholz alarm, Oil Temp alarm & Wdg Temp alram for Transformer feeder only(j) Relay setting after commissioning of VCB according to load/fault condition with secondary injection.(k) Provn of space heater and thermostat for heating(l) 03 No. PT 11 KV/√3/110V/√3/110V/√3 class 1.0/3 P 50VA(m) 3 Nos CT 125-75/1-1A, class1.0/5P10: 5 VA(n) Make of vaccum interupeter, circuit breaker, panels and relays shall be same make.(o) Power pack of 230V AC , 24 DC of minimum 30 minutes backup.Note :- (i) PCC platform/plinth shall be constructed as per OEM recommandation and rate for the same shall deemed to be included in quoted rates. (ii) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. 154 M&L for MS cross arm, bracing, supports, clamps and back plates fabricated from structural steel sections including MS nuts. Bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer all as specified and directed 155 M&L for Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) and fixing on Electric Poles with binding to Insulators with Aluminium Binding Wire as in OH Conductors including Stringing, Tightening, complete all as specified and directed 156 Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 240 sq mm, complete all as specified and directed. 157 Disconnecting and shifting of transformer of capacity 63 KVA with 33/0.433 KV bus bar form existing location to near by location by mechanically and reconnect the same, complete all as specified and directed. 158 Supply and fixing armoured copper control cable of 4 Sqmm, 4core for 33kV and 11kV VCB Circuit wiring with transformer complete all as specified all as specified and directed. 159 Supply and fixing armoured copper control cable of 2.5 Sqmm 10 core for 33KV and 11KV VCB Circuit wiring with transformer, complete all as specified and directed. 160 Supply and install steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP - 55 (11.0 metres long) including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of red oxide primer, externally from top of coping complete all as specified and as directed. (Note :- Excavation, PCC foundation and coping shall be measured and paid separately.) 161 Disconnecting and shifting of control panel form existing location to near by location, complete all as specified and as directed. 162 Supply and fixing cable jointing kit for 11 KV grade cable for indoor termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 sqmm, complete all as specified and directed. 163 Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 sqmm, complete all as specified and directed 164 Supply and layinggravel 63 mm, complete all as specified and directed. 165 Supply and fixing post insulators for 33 KV, complete all as specified and directed. 166 Supply and fixing pin insulators for 33 KV , complete all as specified and directed. 167 Supply and fixing disc insulators for 33 KV, complete all as specified and directed. 168 M&L earthing complete with copper earth plate electrode 600mmx600mmx3.15mm thick,thick burried directly in ground vertically to a depth not less than 3.0 mtr deep below GL with top edge of the plate not less than 2.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common saltupto 1.5 meter depth all around the earth plate and connected to earth leadof copper strip 20x3.15 mm by means of bolts, nuts, check nuts and washers of GI or steel and thimbles and other end of the earth wire connected to DB and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009 and also including making test point for testing of earthingmade out ofgun metal or phosphorous bronge size 75x75x25 mm complete .Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover.2. Charcoal dust and commonsaltupto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate. 3.On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values.(3) The cost ofGI earth lead & G Ipipe of 7.50 mtr length for protection of GI wire and excavation work for pit shalldeemed to be included in this item.Note:- Earthing test will be carried out and if desired result item not achieved the earthing will be redone to achieve desired result without any extra payment. 169 Supply and fixing copper strip of size 20x3mm, complete all as specified and directed. 170 M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.(NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid for). 171 M & L for Cement concrete in foundations, filling and mass concrete PCC 1:5:10 type E2 (40mm graded), complete all as specified and directed. 172 Supply and Fixing of MCB TPN40 Amps, 415 Volts, 50 Hz with 10 KA C curve complete with connection testing and commissioning, complete all as specified & directed. 173 M&L for HDPE Double wall corrugated duct pipe of size 77mm OD and 63mm ID for cable protection laid in trenches complete all as specified and directed. 174 Supply and laying un-reinforced precast cement concrete cable covers, class HV, flat, type-1 of size 300mm x 180mm x 40mm in trenches for cable protection, embossed with ELECTRIC on the top surface complete all as specified and as directed. 175 Supply and fixing electric water heater storage type steel body with MS inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, PVC hot and cold, plug top etc. complete all as specified and directed. 176 Supplying and laying of CPVC pipes 16 mm dia SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all asspecified and directed. 177 Supply and fixing of 15mm bore bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed. 178 Supply and fixing of 15mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed. 179 M&L for Point wiring with 4.0 Sqmm (36/0.30mm)PVC insulated andunsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.6mm thick, with 3mm thickplastic laminated sheet cover of adequate size for AC point wiring and Geyser point wiring incl 4.0 Sqmm (nominalarea) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of AC point and Geyser point at other end complete as per site requirement and all as specified & directed.Note:-Unit rate include for cutting chases for conduits and sinking for boxes andmaking good to wall, floors etc. 180 Supply and fixing sheet metal encloures with plug socket single pole and neutal with two pin and earth plug and with one MCB of 20 Amps (SP), for AC point and Geyser point, complete all as specified and directed. 181 Supply and Fixing MCB SP 20 Amp rating 240V, 10KA C curve for AC point and Geyser pointcomplete with connection testing and commissioning, complete all as specified & directed. 182 Supply and fixing 4 ways TP&N distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCBs 415 volts, 200 Amp rated bus bar with front openable cover suitable for, complete all as specified & directed. 183 Supply and Fixing of MCB TPN32 Amps, 415 Volts, 50 Hz with 10 KA C curve complete with connection testing and commissioning, complete all as specified & directed. 184 Material & Labour in replacement of Earthing complete withgalvanised steel earth plate electrode 60cmx60cmx6 mm thickness burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPMweightnot less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm,excavation and earth work in anytype of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete allto as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion. 185 SCHEDULE OF CREDITNote :- Amount of Rs. 3,68,536.20 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
Contract Date: Feb 10, 2026 Contract Value : 4.02 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
West Bengal View Result →
34.
Housing Urban and Rular Development #9475635 Technical Bid
Tender For Tourism Development Of Kabir Dhuni/Gorakh Talaiya At Sahjanwa Distt. Gorakhpur - Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 3 Filling of carted earth. 4 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 5 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 6 Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. 7 (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 8 (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturers standard dilution) 9 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN LINTEL] 10 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN BEAM] 11 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN SLAB] 12 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN COLUMN] 13 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN FOOTING] 14 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 15 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 16 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 17 Same as in item No. 11 abovebutin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) 18 Ground Floor 19 First Floor 20 Same as in item no. 14 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 21 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars 22 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. 23 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand 24 Ground Floor 25 First Floor 26 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 finesand. 27 Ground Floor 28 First Floor 29 Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required. 30 Supply & fixing 6mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supply of all materials, labour and Tool & plants. 31 Supply & fixing 6mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supply of all materials, labour and Tool & plants. 32 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mm (Flooring) 33 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mm (Skirting) 34 Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm [IN FLOORING] 35 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment 36 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 37 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 38 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood 39 Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable doublenylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. 40 Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares anddrainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 41 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) 42 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) 43 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 44 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (Ceiling) 45 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 46 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. 47 Providing & fixingAluminiumsliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm. 48 Providing and fixingAluminium. anodised towerbolts (barrel type) with necessary screws etc. complete. 49 (a) 250 mm x 10mm 50 Providing and fixing S.S anodised handles with screws etc. complete (a) 125 mm. 51 Providing & laying brick coba 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30cm x cm and side wall parapet shall be mono tythic plaster wall upto 30 cm higher and junction 52 and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acelic water proofing compound @ 2% by weight & including S/o all material, labour, T & P etc complete for proper completion of work. 53 Painting with synthetic enamel paint of approved brand and manufacture of required colourto give an even shade : 54 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 55 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 56 Construction of drain alongwith apron. 57 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. 58 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc.p 59 Centering and shuttering including strutting, propping etc. and removal of form for : 60 (a) Foundations, footings, bases of columns, etc. for mass concrete 61 (b) Suspended floors, roofs, landings, balconies and access platform 62 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 63 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 64 Providingandfixingtiledfalseceilingofspecifiedmaterialsofsize 595x595mmintruehorizontallevel,suspendedoninterlockingmetalgrid ofhotdippedgalvanizedsteelsections(galvanized@120grams/sqm, bothsideinclusive)consistingofmain“T”runnerwithsuitablyspaced jointstogetrequiredlengthandofsize24x38mm madefrom0.30mm thick(minimum)sheet,spacedat1200mmcentertocenterandcross “T”ofsize24x25mmmadeof0.30mmthick(minimum)sheet,1200 mmlongspacedbetweenmain“T”at600mmcentertocentertoform agridof1200x600mmandsecondarycross“T”oflength600mmand size24x25mmmadeof0.30mmthick(minimum)sheettobeinterlocked atmiddleofthe1200x600mmpaneltoformgridsof600x600mmand wallangleofsize24x24x0.3mmand layingfalseceilingtilesofapproved textureinthegridincluding,requiredcutting/making, openingforservices likediffusers,grills,lightfittings,fixtures,smokedetectorsetc. 65 Main“T” runnerstobesuspendedfromceilingusingGIslottedcleatsofsize27x 37x25x1.6mmfixedtoceilingwith12.5mmdiaand50mmlongdash fasteners,4mmGIadjustablerodswithgalvanisedbutterflylevelclipsof size85x30x0.8mmspacedat1200mmcentertocenteralongmainT, bottomexposedwidthof24mmofallT-sectionsshallbepre-paintedwith polyesterpaint,allcompleteforallheightsasperspecifications,drawings andasdirectedbyEngineer-in-charge. 66 12.5mmthicksquareedgePVCLaminatedGypsum Tileofsize595x595mm,madeofGypsumplasterboard, manufacturedfromnaturalgypsumasperIS2095part|and laminatedwithwhite0.16mmthickfireretardantPVCfilm onthefacesideand12micronmetalizedpolyesteronthe backsidewithalledgessealedwiththefacesidePVCfilm whichgoesaroundandwrapstheedgesandisbondedto theedgesandthebacksidemetalizedpolyesterfilmsoasto makethetileacompletelysealedunit. 67 Internal Electrification (Yatri Hall) 68 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 69 Group C 70 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 71 Submains : 72 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 73 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 74 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 75 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 76 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 77 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 78 20 mm 79 25 mm 80 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 81 5/6 A switch 82 3 pin 5/6 A socket outlet 83 TV antenna socket outlet 84 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 85 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 86 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 87 1 or 2 Module (75mmX75mm) 88 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 89 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 90 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 91 Upto 450 mm sweep 92 MCBs & DB’s : 93 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 94 4 way (4 + 12), Double door 95 6 way (4 + 18), Double door 96 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 97 4 way (4 + 12), Double door 98 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 99 Single pole 100 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 101 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 102 100 A,30KA,FPMCCB 103 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 104 Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A 105 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 106 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 107 ELCB/RCCB Switches : 108 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 109 40 A 110 63 A 111 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 112 Earthing Work : 113 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 114 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 115 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 116 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 117 100 mm width X 50 mm depth X 1.6 mm thickness 118 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 119 Lighting Fixtures (Lights/Fans) : 120 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 121 Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect . 122 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 123 Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter complete in all respect. 124 Armoured Cables (Cable/Gland/Lug) : 125 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 126 size 25 sq mm x 3-1/2core 127 size 35 sq mm x 3-1/2core 128 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable 129 size 25 sq mm x 3-1/2core 130 size 35 sq mm x 3-1/2core 131 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 132 size 25 sq mm 133 size 35 sq mm 134 L.T. Switch Panel Board : 135 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. 136 The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. 137 The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type 138 Incoming - 139 200 Amp MCCB-1 No. 140 Outgoing - 141 100 Amp 4P MCCB - 2 Nos. (for VTPN D.B. DBs) 142 100 Amp 4P MCCB - 2 Nos. (for VTPN D.B. DBs) 143 63 Amp 4P MCCB - 1 Nos. (for Terrace pump)) 144 40 Amp DP MCB - 2 Nos. (Spare) 145 (or As per requirment directed by Project Manager.) 146 Non-Schedule Items 147 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 148 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 149 INTERNAL SANITARY (Yatri Hall) 150 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required 151 W.C. pan with ISI marked white plastic seat and lid 152 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 153 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. 154 Providing and fixing wash basin with C.I. brackets, 15 mm dia C.P. brass Single Hole Basin Mixture approved quality and make ,including painting of fittings and brackets, cutting and making good the walls wherever require. 155 a)White Vitreous China wash basin size 550x 400 mm with 15 mm dia C.P. brass Single Hole Basin Mixture. 156 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 157 Semi rigid pipe 158 a) 32mm dia 159 b) 40mm dia 160 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 161 Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 162 15mm nominal bore 163 Providing and fixing CP Brass 32 mm sizeBottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. 164 Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. 165 a) 15mm dia nominal dia. 166 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 167 a) 100 mm diameter 168 Providing and fixing Toilet paper holder 169 a) C.P. brass 170 Providing & fixing 600x120x5 mm glass self with edges round off, supported on anodiesd aluminium angle framewith C.P. brass bracket and guard rail complete fixed with 40 mmlong screws, rawl plugs etc, complete. 171 Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. 172 Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. 173 Providing & fixing 32 # G.I. Pipes spout including cutting & making good the walls etc. 174 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 175 110mm diameter 176 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 177 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 178 110mm 179 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 180 Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. 181 (internal work) 182 Exposed on wall 183 32mm dia nominal bore 184 Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 185 32mm dia nominal bore. 186 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 187 internal work -Exposed on wall 188 20mm dia nominal outer dia pipes 189 25mm dia nominal outer dia pipes 190 32mm dia nominal outer dia pipes 191 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. 192 Concealed work including cutting chases and making good the walls etc. 193 15mm dia nominal outer dia pipes 194 20mm dia nominal outer dia pipes 195 25mm dia nominal outer dia pipes 196 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 197 15mm nominal bore 198 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 199 15mm nominal bore 200 Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 201 Providing and fixing gun metal gate valve with wheel of approved quality. 202 25mm dia nominal bore 203 20 mm dia nominal bore 204 32mm dia nominal bore 205 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 206 25 mm nominal bore 207 Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 208 Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, 209 in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. 210 Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. 211 Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 212 100mm diameter 213 150mm diameter 214 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 215 100mm diameterS.W. Pipe 216 150mm diameterS.W. Pipe 217 Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 218 150 x 100 mm. size P type 219 With Sewer bricks conforming to IS : 4885 220 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design 221 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). 222 With FPS bricks of class designation 75 223 (i) For Sewer Line 224 Extra for depth of man hole size 90x80 cm 225 Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. 226 Extra for depth of man hole size 90x120 cm 227 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design 228 With 20x20 mm square bar 229 EXTERNAL WATER SUPPLY SYSTEM 230 Provding and fixing gun metal non return valve of approved quality (screwed end) 231 50 mm nominal bore 232 Vertical 233 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. 234 External work 235 32mm nominal bore. 236 50mm nominal bore. 237 Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. 238 32 mm diameter pipe 239 50 mm diameter pipe 240 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 241 32 mm nominal bore 242 50 mm nominal bore 243 Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 244 With F.P.S. bricks 245 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 246 25 to 40 mm dia nominal bore 247 50 to 80 mm dia nominal bore 248 Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 249 90 mm O.D. 250 110 mm O.D. 251 Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. 252 Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. 253 Size 90 mm 254 Size 110 mm 255 Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. 256 Size 75/90 mm 257 Size 110 mm 258 Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. 259 Size 90x90x90 mm 260 Size 110x110x110 mm 261 Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. 262 Size 90 mm 263 Size 110 mm 264 FIRE FIGHTING 265 (A) Supplying, Installation, Testing & Commissioning ofElectric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required:(Terrace Pump) 266 (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520. 267 (C) Suitable HP Squirrel cage indution motor, TEFC type suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, confirming to IS-325. 268 (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. 269 (E) Suitable cement concrete foundation duly plastered with anti vibration pads. 270 450 lpm at 35 m head 271 Providing, laying, testing & Commissioning ofC class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 272 25 mm dia 273 100 mm dia 274 Supplying & fixing single headed internal yard hydrant valve with instantaneousGunmetal/Stainless Steel coupling of63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: 275 Single headed Gunmetal 276 Supplying, fixing, testing & commission of butterfly valve ofPN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 277 100 mm dia 278 Supplying & fixing orifice plate made out of 6 mm thick stainless steel(grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required: 279 Providing, installation, testing and commission of non-return valve offollowing sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 280 100 mm dia 281 Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: 282 Gun Metal 283 Supplying & fixing First-aid hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. 284 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 285 20 mm nominal internal dia gun metal globe valve & nozzle. 286 Drum and brackets for fixing the equipments on wall. 287 Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 288 30 m 289 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. 290 Gun Metal 291 Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 292 Providing & fixing of pressure switch in M.S. pipe line including connection etc as required. 293 Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 294 FIRE DETECTION & ALARM SYSTEM 295 Supplying, installation, testing & commissioning of Manual call Boxes of MS constuction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 296 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box(16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required. 297 Supplying & laying of 2X1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 298 Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 299 25mm 300 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilityes as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 301 4 Zone 302 Providing, laying, testing & Commissioning ofC class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 303 80 mm dia 304 100 mm dia 305 Supplying & fixing single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: 306 Single headed Gunmetal 307 Supplying, fixing, testing & commission of butterfly valve ofPN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 308 80 mm dia 309 100 mm dia 310 Providing, installation, testing and commission of non-return valve offollowing sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 311 100 mm dia 312 Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: 313 Gun Metal 314 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. 315 Gun Metal 316 Supplying & fixing ofFire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required. for suitable dia MS pipe connection conforming to IS 904 as required: 317 2 way-100 mm dia M.S. Pipe 318 Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 319 Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 320 Providing/Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted “FIRE” in red luminous paint. The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete.Make : Standard/Lifeguard or EQ. 321 Supplying and fixing of Fire man axe.Make :- Agni Suraksha (ASES) or EQ 322 Supply, Installation, Testing and Commissioning of electronic siren with suitable audible range of 1 k.m. approximately 4 watt.complete in all respects. Make :- Agni Suraksha (ASES) or EQ. 323 Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprisingof :a) 40 amp 3 Pole MCCB, 50Hz with breaking capacity 10KW.b)One Volt meter (0-500 V) with selector switch.c) One set including lamps.Make :- Make :- Agni Suraksha (ASES)/ABB/L&T or EQ. 324 SEPTIC TANK & SOAK PIT 325 Size :- Length = 5.00 M. Width = 2.00M Total Depth =3.00M 326 Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. 327 In all kind of soil upto 1.5m depth 328 In all kind of soil upto 1.5m to 3.0m. depth 329 In all kind of soil upto 3.0m to 4.5m. depth 330 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 20mm nominal size) 331 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 332 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) including centering and shuttering and reinforcement. 333 TMT Fe-500 in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 334 15mm cement plaster on rough side of mix 1:4 (1 cement : 4 coarse sand) 335 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 336 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 337 Providing & fixing 75mm dia vent pipes. 338 Providing & fixing of 75mm dia cast iron terminal guard. 339 M.D. -10- Circular shape 500mm internal diameter 340 M.D. -2.5- Circular shape 450mm internal diameter 341 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. 342 With F.P.S. bricks 343 Centering and shuttering including strutting, propping etc. and removal. 344 UPGRADATION OF BOUNDRY WALL (519.20 RM) 345 R.C.C. work in Beam 346 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 347 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 348 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick workbending for proper shap as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured. 349 M-150 Brick work in Super Structure in 1:6 cement and coarse sand mortar necessary cutting & moulding of brick as required thickness of walls not to be less than 1-1/2 brick. including supply of all materiallabour, Tools & Plants etc.required for proper completion of the work 350 12 mm cement plasterinsingle coat on fair sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth.(1)1 cement:6 fine sand 1.25 F.M. 351 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm 352 Steel reinforcement for R.C.C. work ready to use “cut and bend” rebars of approved make fromfactory/workshop to construction site includin placing in position and binding all complete above plinth level. 5.22C.1 Thermo-Mechanically Treated bars of grade Fe-500D or more. 353 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 354 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 355 Centering and shuttering including strutting, propping etc. and removal of form for 356 Lintels, beams, plinth beams, girders, bressumers andcantilevers 357 Centering and shuttering including strutting, propping etc. and removal of form for 358 Column 359 COST OF SIGNAGE /INTERPATION WALL about theme of Kabir das gurunanak ravidas & Guru Gorakhsh Nath & Sant Keshavdas (CIVIL WORK) (07 Nos) 360 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 361 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone ballast 40 mm nominal size) and curing complete,including cost of form- work, in foundation. 362 R.C.C. (M-20) work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. 363 As in item 3 abovebut inR.C.C.beamwithapproved stone ballast.(Using1:1.5:3Mix concrete) 364 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in footing excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.(M-20) 365 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in columns excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.(M-20) 366 P/F TMT Bar -Fe 500 in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 367 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 368 Red sand stone - Exposed face machine cut and table rubbed with rough backing. 40 mm thick 369 Centering and shuttering including strutting, propping etc. and removal of form for : 370 (a) Foundations, footings, bases of columns, etc. for mass concrete 371 (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers 372 (c) Columns, Pillars, Piers, Abutments, Posts and Struts 373 INTERLOCKING PAVER front side parking (971.50 sqm) 374 Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. (DSR 2.8.1) 375 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 376 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 377 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge. 378 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern 379 SAND STONE PATHWAY (arround kund & green area) 1631 SQM) 380 Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. (DSR 2.8.1) 381 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 382 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 383 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone 384 HORTICULTURE AND LANDSCAPING 385 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 386 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 387 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). 388 Supplying and stacking well decomposed cow dung manure at site including royalty and carriage upto site (cow dung measured in stacked will be reduced by 8% for payment.) 389 Anti termite treatment of lawn area through premise 30.50% I P. one literpremise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. 390 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 391 GRASS PLANTING WORK 392 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge 393 GROUND COVER/ PLANTING WORKS 394 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) 395 SHRUB PLANTING WORKS 396 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) 397 Holes 60 cm dia, and 60 cm deep 398 Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge. 399 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35- 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 400 Providing and stacking of Ficus blackii (F.vivion) of height 45-60 cm. with 6- 8 branches healthy foliage in earthen pots of size 25 cm as per direction of the officer-in-charge. 401 Providing and Displaying Ficus black vivion piller Topiary (sylinder type) well developed with fresh & healthy 180 to 210 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge. 402 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 403 Providing and Displaying Bamboo Buddha Valley with fresh & healthy 5 to 6 suckers 1.80 m to 2.10m ht umbrella type well developed in 50 cm Cement Pot as per direction of the officer-in-charge. 404 Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge. 405 Providing and stacking of Polyalthia pendula (Ashok Pendula) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 406 External water suplly from submersiblepump (85 RM) (Detail As per TS Estimate) 407 GAZIBO (2 Nos) 408 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 409 Filling of Carted earth 410 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. 411 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 412 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground 413 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 414 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 415 R.C.C. work in slab 416 R.C.C.work in beams 417 R.C.C.work in footing foundation 418 R.C.C.work in Column 419 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 420 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 421 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 422 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 423 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 424 15 mm cement plaster on rough side of single or half brick wall of mix: 425 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 426 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 427 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 428 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 429 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 430 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,V epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 431 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 432 Centering and shuttering including strutting, propping etc. and removal of form for : 433 (a) Foundations, footings, bases of columns, etc. for mass concrete 434 (b) Suspended floors, roofs, landings, balconies and access platform 435 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 436 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 437 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 438 Red sand stone - Exposed face machine cut and table rubbed with rough backing 439 ELECTRICAL WORK 440 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 441 Group C 442 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 443 Submains : 444 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 445 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 446 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 447 20 mm 448 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 449 5/6 A switch 450 3 pin 5/6 A socket outlet 451 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 452 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 453 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 454 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 455 MCBs & DB’s : 456 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 457 4 way (4 + 12), Double door 458 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 459 Single pole 460 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 461 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 462 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 463 ELCB/RCCB Switches : 464 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 465 40 A 466 Earthing Work : 467 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 468 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 469 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 470 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 471 Non-Schedule Items 472 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 473 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 474 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 475 PLUMBING WORK 476 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 477 110 mm 478 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 479 110 mm 480 [GAZIBO ] EXTRA HEIGHT (02 Nos) 481 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 482 Filling of Carted earth 483 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. 484 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 485 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground 486 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 487 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 488 R.C.C. work in slab 489 R.C.C.work in beams 490 R.C.C.work in footing foundation 491 R.C.C.work in Column 492 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 493 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 494 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 495 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 496 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 497 15 mm cement plaster on rough side of single or half brick wall of mix: 498 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 499 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 500 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 501 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 502 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 503 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,V epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 504 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 505 Centering and shuttering including strutting, propping etc. and removal of form for : 506 (a) Foundations, footings, bases of columns, etc. for mass concrete 507 (b) Suspended floors, roofs, landings, balconies and access platform 508 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 509 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 510 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) includingpointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sides by means of cramps andpins which shall be paid for separately) : 511 Red sand stone - Exposed face machine cut and table rubbed with rough backing 512 ELECTRICAL WORK 513 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 514 Group C 515 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 516 Submains : 517 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 518 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 519 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 520 20 mm 521 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 522 5/6 A switch 523 3 pin 5/6 A socket outlet 524 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 525 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 526 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 527 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 528 MCBs & DB’s : 529 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 530 4 way (4 + 12), Double door 531 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 532 Single pole 533 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 534 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 535 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 536 ELCB/RCCB Switches : 537 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 538 40 A 539 Earthing Work : 540 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 541 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 542 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 543 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 544 Non-Schedule Items 545 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 546 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 547 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 548 PLUMBING WORK 549 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 550 110 mm 551 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 552 110 mm 553 COST OF STONE BENCHE (Supply, and fixing in position 3 seater sand Stone Benches, 1800*600*450 mm at site as per approved quality and design. including all cost of accesories, transportation etc. complete in all respect.) (Detail As per TS Estimate) 554 SOLAR LIGHTall in one Philips (Detail As per TS Estimate) 555 CONTROLLING WATER LOSSES IN GORAKH TALAIYA KUND 556 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. 557 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green.Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. 558 HDPE SHEET 1 Layer at pond bottom(800 MICRON) 559 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-III) including manufactured sand derived fromRecycled Concrete Aggregate (RCA) upto 25% : 3 graded stone aggregate 20 mm nominalsize including Recycled Concrete Aggregate (RCA) upto 25%). 560 Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 561 MINI POND & CONNECTION 562 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. 563 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 564 Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) 565 Raised and cut pointing on stone work in white cement mortar 1:3 (1 white cement : 3marble dust). 566 Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressedstones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. all complete. (Payment for Stone to be made separately). 567 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 568 400 mm dia 569 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design 570 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover108 kg and weight of frame 100 kg) : 571 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 572 (i) For PIPE Line 573 Extra for depth of man hole size 90x120 cm 574 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 575 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 576 For pipes 350 to 450 mm diameter 577 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete 578 450.mm diameter 579 Boring 580 T.W. boring of 200 mm dia with 150 mm dia P.V.C. pipe assembly, 7.50 H.P. submersible pump including supply of all accessories starter, panel etc. & pipe arrangements complete. 581 8 PVC casing pipe of ISI mark. 582 P/ F 3 GI pipe (B) class. 583 Nylon mesh for filter. 584 Plastic dori. 585 Solvent cement. 586 8 End cap. 587 8 Submersible cap. 588 3 MS clamp (Heavy). 589 3 GI elbow. 590 3 X 6 GI nipple. 591 7.5 HP 9 Stage submersible pump of ISI mark with automatic panel. 592 4.00 sqm. Submersible cable. 593 Drilling charges for16 dia tubewell. 594 Pea Gravel. 595 2 MS socket. 596 Rope with plastic coated 597 Cartage of material upto site. 598 water collection tank at ground lvl(haudi) 599 Shop 01 Nos 600 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 601 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 602 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 603 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 604 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground. 605 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 606 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 607 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 608 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 609 R.C.C. (M-20) work with cement approved coarse sand and 20 mm. guage approved stone grit in the proportion of 1:1.5:3 in Lighter Beam excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. 610 R.C.C. Work IN FOOTING 611 R.C.C. Work in column 612 M-150 brick work in one cement & 6 coarse sand 2.25 F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work. 613 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 614 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 615 M-150 Brick work in super-structure above plinth level up to floor two level (up to two storeys) includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) 616 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 617 Providing & laying brick Coba 120mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of 618 coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick 619 ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. 620 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 621 35 mm thick (Single Leaf) 622 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) both Side 623 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 624 Hold fast for chaukhats of doors/windows. 625 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a) Second class teak wood 626 TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 627 Fixing of Door, windows/ventilators chaukhats in position. 628 (a) Door 629 15 mm thick plaster with cement mortar in proportion of 1:4 (1 cement: 4 coarse sand) cement & coarse sand in plinth. 630 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25 631 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand. 2.25.F.M. 632 12 mm cement plaster in ceiling to finshed even and smooth with mix of 1 cement : 3 coarse sand. 633 Addforplasterdripcourse/grooveinplasteredsurfaceormouldingto R.C.C.projections. 634 Ground & First floor 635 40mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. 636 Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work excluding base concrete. 637 Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work excluding base concrete. 638 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 639 Granite of any colour and shade (Area of slab over 0.50 sqm) 640 Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3, Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt, dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. 641 Same as item above but on new wood surface. 642 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 643 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) 644 Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. 645 Supplying and fixing rolling SHUTTERS of approved make made 80x125mm (3x5) cold rolled M.S. lath inter locked throughout their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top cover and springs. 646 Providing and fixing ball bearing for rolling shutters. 647 Red Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 40 mm thick 648 S.S.Cramp 649 Making of draing along with apron 150 X 150 MM 650 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter 651 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermalexpansion. 110 mm bend 652 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 653 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 654 Centering and shuttering including strutting, propping etc. and removal of form for : 655 (a) Lintels, beams, plinth beams, girders, bressumers and cantilevers 656 (b) Suspended floors, roofs, landings, balconies and access platform 657 (c) Foundations, footings, bases of columns, etc. for mass concrete 658 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 659 ELECTRICAL WORK 660 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 661 Group C 662 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 663 Submains : 664 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 665 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 666 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 667 20 mm 668 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 669 5/6 A switch 670 3 pin 5/6 A socket outlet 671 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 672 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 673 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 674 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 675 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 676 Upto 450 mm sweep 677 MCBs & DB’s : 678 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 679 4 way (4 + 12), Double door 680 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 681 Single pole 682 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 683 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 684 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 685 ELCB/RCCB Switches : 686 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 687 40 A 688 Earthing Work : 689 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 690 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 691 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 692 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 693 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 694 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 695 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 696 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 697 EARTH FILLING ON SITE 698 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 699 High Mast Light 700 Supply & Installation of High Mast 12.0mtr. Long with 180 watt LED 6 No. fitting with IP 65 Protection complete in all respect.(Including Panel) 701 supply and fixing of 15 amp SPN automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors ,HRC fuse,isolating switch,metering instrument,and instrument box with CTs etc.complete in all respect. 702 Cables 703 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size 704 size 6 sq mm x 2 core 705 size 10 sq mm x 4 core 706 size 25 sq mm x 3-1/2core 707 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge.for cable 708 size 6 sq mm 709 size 10 sq mm 710 size 25 sq mm 711 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 712 size 6 sq mm 713 size 10 sq mm 714 External Painting on Existing Building 715 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 716 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on ceiling to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. (Inner walls) 717 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 718 Scraping old whit & colour wash including disposal of refuse as directed by the Engineer-in-charge with in a distance of 60m (Inner Wall) 719 SAND STONE FLOORING ON POND STEP & CHABUTRA EXTENSION & GRANIET FLOORING 720 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone 721 S.S. RAILING 722 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. 723 Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm [IN FLOORING] 724 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 725 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 726 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 727 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 728 Centering and shuttering including strutting, propping etc. and removal of form for : 729 (a) Lintels, beams, plinth beams, girders, bressumers and cantilevers 730 DRAIN 300X450 (LENTH =75+30.6 +117.7+45.7 MTR) (269 RMT) 731 Earth work in excavation 732 P.C.C. 1:4:8 733 Brick work in 1:4in foundation. 734 12 MM thick plaster (1:4) 735 C.C. flooring 736 DISMATELLING & RECONSTRUCTION OF BOUNDRY WALL TWO PANNEL FOR HYDROLIC MECH. ( 5.120 Rmt.) 737 As per Details TS Estimate 738 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 739 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 740 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick workbending for proper shap as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured. 741 M-150 Brick work in Super Structure in 1:6 cement and coarse sand mortar necessary cutting & moulding of brick as required thickness of walls not to be less than 1-1/2 brick. including supply of all materiallabour, Tools & Plants etc.required for proper completion of the work 742 12 mm cement plasterinsingle coat on fair sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth.(1)1 cement:6 fine sand 1.25 F.M. 743 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm 744 Steel reinforcement for R.C.C. work ready to use “cut and bend” rebars of approved make fromfactory/workshop to construction site includin placing in position and binding all complete above plinth level. 5.22C.1 Thermo-Mechanically Treated bars of grade Fe-500D or more. 745 As per Details TS Estimate 746 Two or more coats on new work over an under coat of suitable shade with ordinary paint ofapproved brand and manufacture 747 Centering and shuttering including strutting, propping etc. and removal of form for 748 Lintels, beams, plinth beams, girders, bressumers andcantilevers 749 Centering and shuttering including strutting, propping etc. and removal of form for 750 Column 751 Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 752 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - incharge. 753 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. cum 494.10 Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 754 WALL CUTTING 755 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 756 a) 110mm diameter 757 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing completeso as to make it leak proof. 758 KITCHEN 759 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 760 Filling of Carted earth 761 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. 762 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 763 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground 764 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 765 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 766 R.C.C. work in slab 767 R.C.C.work in beams 768 R.C.C.work in footing foundation 769 R.C.C.work in Column 770 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 771 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 772 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 773 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 774 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 775 15 mm cement plaster on rough side of single or half brick wall of mix: 776 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 777 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand 778 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 779 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) 780 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 781 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 782 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 783 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 784 Centering and shuttering including strutting, propping etc. and removal of form for : 785 (a) Foundations, footings, bases of columns, etc. for mass concrete 786 (b) Suspended floors, roofs, landings, balconies and access platform 787 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 788 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 789 Providing & laying brick coba 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30cm x cm and side wall parapet shall be mono tythic plaster wall upto 30 cm higher and junction 790 and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acelic water proofing compound @ 2% by weight & including S/o all material, labour, T & P etc complete for proper completion of work. 791 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut withthe zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 792 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut withthe zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 793 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 794 (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 795 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 796 Hold fast for chaukhats of doors/windows. 797 Door / windows & Staircase grill. 798 Angle iron chaukhats size 40x40x5 799 Z Section steel window 800 Fixing of Door, windows/ventilators chaukhats in position. 801 (a) Door 802 (b) Windows 803 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). 804 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 805 Providing & fixingAluminiumsliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm. 806 Providing and fixingAluminium. anodised towerbolts (barrel type) with necessary screws etc. complete. 807 (a)250 mm x 10mm 808 (a) 200 mm x 10mm 809 Providing and fixing S.S anodised handles with screws etc. complete (a) 125 mm. 810 Wiringforlightpoint/fanpoint/exhaustfan point/callbellpointwith1.5sq.mmFRLSPVC insulatedcopperconductorsinglecorecablein surface/recessedmediumclassPVCconduit, withmodulartypeswitch,modularplate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 811 Group C 812 Wiringforcircuit/sub-mainwiringalongwith earthwirewiththefollowingsizeofFRPVC insulatedcopperconductor,singlecorecablein surface/ recessedmediumclassPVC conduitasrequired. 813 2X1.5 sqmm + 1x1.5 sqmm earth wire 814 2X2.5 sqmm + 1x 2.5 sqmm earth wire 815 2X4.0 sqmm + 1x 4.0 sqmm earth wire 816 2X6.0 sqmm + 1x 6.0 sqmm earth wire 817 Supplyinganddrawingco-axialTVcableRG-6 graded,0.7mmsolidcopperconductorPE insulated,shieldedwithfinetinnedcopperbraid andprotectedwithPVCsheathintheexisting surface/ recessed steel/ PVC conduit asrequired. 818 Say Rs. 819 Supply and fixing of following size of PVC conduitalongwiththeaccessoriesinrecess includingpaintingincaseofsurfaceconduit,or cuttingthewallandmakinggoodthesameincase of recessed conduit as required: 820 20mm 821 Supplyingandfixingfollowingmodularswitch/ socketonthe existingmodularplate&switch boxincludingconnectionsbutexcludingmodular plate etc as required. 822 TV antenna socket outlet 823 Supply and fixing of stepped type electronic fan regulatorontheexistingmodularplateswitch boxincludingconnectionsbutexcluding modular plate etc. as required. 824 Supplying and fixing modular blanking plate on the existing modular plate & switch boxexcluding modular plate as required. 825 Supplying and fixingfollowing size/modules,GIboxalongwithmodularbase &coverplate for modular switches in recess etc as required. 826 1 or 2 module(75mm X 75 mm ) 827 SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modularsocketoutletand5/6Amodularswitch,connection etc. as required. 828 SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. 829 Supplyingandfixing3pin5Aceilingroseon the existing junction box/woodedn blockincluding connectionetc. as required. 830 Supplyingandfixingbrassbatten/angleholderincluding connectionetc. as required. 831 Instalation,testing&commissioningofwall bracket/ceilingfittingsofallsizesandshapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories includingconnection etc. as required. 832 Installation, testing and commissioning of prewired,flourescentfitting/compact fluorescent fitting of all types,completewithall accessoriesandtubesetc.directlyonceiling/ wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. 833 Installation, testing and commissioning of ceiling fan,includingwiring thedownrodsof standard length(upto30cm)with1.5sq.mmFRLSPVC insulated, copper conductor, single core cable etc. Includingprovidingandfixingphenolic laminated sheet cover on the fan box etc. asrequired. 834 Numbering of ceiling fan/ exhaust fan/fluorescent fittings as required. 835 Installationofexhaustfanintheexisting opening, including making good the damage, connections, testing, commissioning etc. as required. 836 upto 450 mm sweep. 837 Extraforfixingthelouvers/shutterscomplete with frame fro exhaust fans of all sizes. 838 Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB,`C`curveincludingconnections,paintingetc. as required. 839 Providing and fixing circular/Hexagonal cast ironorM.S.sheetboxforceilingfanclamp,of internal dia 140 mm,73mmheight,top lidof 1.5 mmthickM.S.sheetwithitstopsurfacehacked for proper bonding, top lid shall bescrewed into the cast iron/M.S. sheet box by means of 3.3 mm diaroundheadedscrewed,onelocatthe conrners.Clampshallbemade of12mmdiaM.S. bar bent to shape as per standard drawing. 840 Supply,Installation,TestingandCommissioning of1200mmsweep,BEE5starrated,ceilingfan with Brush Less Disect Current(BLDC) motor, classofinsulation:B,3nos.blades,30cmlong down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9,ServiceValue(CM/M/W)minimum6,Airdelivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than10%remoteorelectronicregulatorunitfor speedcontrolandallremainingaccessories including safety pin, nut bolts, washers, temperaturerise=75degreeC(max.),insulation resistancemorethan2megaohm,suitablefor 230V,50Hz,singlephaseACSupply,earthingetc. complete as required. 841 Supplyingandfixing following way,singlepole and neutral sheet steel, MCB distribution board, 240Vonsurface/recesscomplete with,tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthingetc. asrequired(ButwithoutMCB/ RCCB / Isolators). 842 12 way, Double door 843 Supplying and fixing 5 amps. to 32 amps. rating,240volts `Cseries, miniaturecircuit breaker (MCB)suitableforinductiveloadof following poles in theexisting MCB DB completewith connections,testingand commissioningetc.as required. 844 Single Pole 845 Double Pole 846 Supplyingandfixingsinglepole,blankingplate intheexistingMCBDBcompleteetc.asrequired. 847 EarthingwithGIearthpipe,600mmX600 mmX 6 mm thick including accessories and providingmasonaryenclosurewith coverplate having locking arrangementandwateringpipe of 2.7 metre long etc, with charcoal/cock and salt as required. 848 Supplying and Laying of 25 mm X 3 mm G.I strip at0.50metrebelowgroundasstripearth electrode, including connection / terminating withnut,bolt,spring,washeretc.asrequired.( jointing shall be done by overlapping and with 2 setsofG.I.nutbolt&springwasherspacedat50mm) 849 Supplying and Laying of 6 SWG G.I wireat 0.50 metre belowgroundlevelforconductorearth electrode, including connection / terminating with G.I. thimble etc. as required. 850 LayingofonenumberPVCinsulatedandPVC sheathed/XLPEpowercableof1.1KVgradeof following size direct in ground including excavation,sandcushioning,protectivecoveringand refilling the trench etc. as required. 851 Upto 35 sq. mm 852 Supplying&makingendterminationwithbrass compressionglandandaluminiumlugsforthe following size of PVC sheathed / XLPE aluminiumconductorcableof1.1KVgradeasrequired. 853 2 X 10 sqmm. (19mm) 854 Providing,layingandfixingfollowingdiaG.I. pipe(mediumclass)ingroundcompletewithG.I. fittings including trenching (75 cm deep) andrefilling etc as required. 855 50 mm Dia(Rate taken From Civil DSR 2021-18.12) 856 Supplyoffollowingsizeof1.1KVgrade multicore aluminium conductor PVC sheathedarmoured cable as per IS 1554. 857 10 sqmm 2 core 858 Supply & fixing of7/9 W LED BULB complete inall respect. 859 Supply and fixing of LED Tube Light with battensuitableforupto1X20wattLEDtube light complete including tube etc. on surfacecomplete in all respect. 860 Supply&fixingofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down LighterhavingPowdercoateddiecast aluminium housing with heat sink, diffuser/Reflectoranddriversetcompleteinallrespects. 861 Cat. AAA 862 Supply ofAC230/250Volts,50Hz55w1400 rpm exhaust fans including providing nuts, bolts, mountingframeandotheraccessoriesincluding connections etc. complete as required.-Make:Havells-STANDARD -Refresh Air-SPS 863 300mm sweep. 864 PLUMBING WORK (As per TS Estimate 865 DRINKING WATER BOOTH 866 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 867 Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 stone ballast 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. 868 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 869 M-150 brick work in one cement & 6 coarse sand 2.25 F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work. 870 R.C.C. work in slab (Using1:1.5:3Mix concrete) 871 As in item 5 abovebut inR.C.C.beamwithapproved stone ballast.(Using1:1.5:3Mix concrete) 872 As in item 5 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. 873 As in item 5 abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast. (Using1:1.5:3Mix concrete) 874 Class M-150 Brick work in super-structure above plinth level includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than one brick thick. (1:4 cement & coarse sand) 875 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) 876 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (Fe-500) 877 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete Granite of any colour and shade 878 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 879 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) 880 Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. 881 Providing and laying water proofing treatment in sunken portion of W.C., bathroom etc, by applying cement slurry mixed with water proofing cement compound consisting of applying :- (a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with water proofing cement compound @ 0.253 kg/Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 882 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 883 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :(15 mm dia) 884 Providing and fixing G.I. Union in G.I. pipeincluding cutting and threading the pipe and making long screws etc. complete (New work) :(15 mm dia) 885 Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc.(25 mm dia) 886 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 887 Supply of 110 mm dia PVC casing pipe for boring 6 kg/sqm ISI approved. 888 WATER TANK 889 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust)with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 890 Red Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 40 mm thick 891 Centering and shuttering including strutting, propping etc. and removal of form for : 892 (a) Foundations, footings, bases of columns, etc. for mass concrete 893 (b) Suspended floors, roofs, landings, balconies and access platform 894 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 895 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 896 GST Extra As per Applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Uttar Pradesh View Result →
35.
Housing Urban and Rular Development #9446222 Technical Bid
Tender For Fire Fighting/Fire Alarm System (Conventional) & PA System Works in BIDA Mart, Bhadohi, 1 Sub Head- 1: External Works 2 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 3 Providing and laying, testing, & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fitting like elbow, tees, flanges, tapes, nut/bolt, gasket etc and fixing the pipe on the wall/ceilling with suitable clamps/support frame and painting with two or more coats of synthetic enamel paint of required shade complete in all respect.150mm nominal bore (pump room, external hydrant, FBI & siamese connection pipe, pump room to FFTG shaft) 4 Providing, fixing,, testing &commissioning of installation control valve of cast iron, brass/bronze working parts comprising of water motor alarm, bronze seat clapper , clapper arm and hydraullic driven mechanical going bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauge, emergency release, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orific plate, gasket etc 150 mm dia. 5 Supplying and fixing of the Fire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as reqd for suitable dia MS pipe connection conforming to IS 904 as rquired for 4 way-150 mm dia MS pipe 6 Sub Head- 2: Internal Fire Fighting Works (Hydrant System) 7 a)Suppling, installation, commissioning& testing of electric driven terrace pump suitable for automatic operation and consisting of following in all respect, as required:((Terrace Pump)b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bromze impeller with stainless steel shaft, mechanical confirming to IS:1520 c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP 55 class of protection for enclosure, Horizontal foot mounted type with Class-F insulation, confirming to IS-325d) MS fabricated common base plate, coupling, coupling guard, foundation bolts etc as required.e) Suitable cement concrete foundation duly plastered and with anti vibration pads.900 lpm at 35m Head 8 Providing & fixing of pressure switch in MS pipe line including connection ectc as required ( for terrace booster pump) 9 Providing and fixing in position the industrial type pressure gauge with gun metal / brass valves complete as required ( for terrace booster pump) 10 Supplying, fixing, testing & commissioning of butterfly valve of PN 1.6 rating with bronze/gun metal seat duly ISI marked complete with nuts, bolts washers, gasketconforming to IS 13095 of 150 mm dia. 11 Providing, installation, testing and commissioning of 150 mm dia non-return valve confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc as required. 12 Providing, laying, testing and commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fitting like elbows, tees, flanges, tapers, nut bolts, gasket etc and fixing the pipe on the wall/ceilling with suitable clamps/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 13 80 mm nominal bore 14 150 mm nominal bore 15 Supplying and fixing of single headed internal hydrant valve with instantaneous Gunmetal/Stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank gunmetal /Stainless steel cap and chain as required:Single headed Gunmetal 16 Supplying and fixing first aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type-2 as per IS:1258520 mm nominal internal dia gun metal globe valve &nozzle. Drum and brackets for fixing the equipments on wall. Connection from riser with 25mm dia stop gun metal valve & MS pipe and socket.40 m 17 Supply and fixing 63mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc conforming to IS 636 (type-A) as required Gun metal 18 Supplying and Fixing 63mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required:Gun Metal 19 Providing and fixing standard fire mans axe with heavy duty insulated rubber handle. 20 Providing of FHC door made of 16 gauge MS sheet with frame of size 105x70mm complete door and frame assembly including all hardwares 9 concealed Flush handle, Allen keu Lock, MS hinges, 5mm Thick Float glass) & accessories. The door to be painted with Fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge. (Approx size of door: 900mm widt & 1500mm Height) 21 Supplying and Fixing orifice plate made out of 6mm thick stainless steel (Grade 304) with orifice of required sizeto be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 22 Supplying and fixing of air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 23 Sub Head- 3: Sprinkler System 24 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinkler of rating 68 degree centigrade with required accessoriesPendent Type Sprinkler 25 Suplying, installation, testing and commissioning of Sprinkler flexible pipe (UL listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175PSI test pressure of 875PSI (Burst) with branch line (Inlet) 25 mm NPT male thread to sprinkler head (Outlet) 15 mm NPT female thread with reducer, nipple, 2side brackets, center bracket, stockbar of length upto 1000 mm sizes complete as required. 26 Providing, laying, tesing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fitting, like elbows, tees, flanges, tapers, nuts bolts, gasket etc and fixing the pipe on the wall /ceilling with suitable clamps/support frame and painting with two coat or more coats of synthetic enamel paint of required shade complete as required. 27 150mm nominal bore 28 100mm nominal bore 29 80mm nominal bore 30 65mm nominal bore 31 50mm nominal bore 32 40mm nominal bore 33 32mm nominal bore 34 25mm nominal bore 35 Providing and fixing flow switch in 150mm dia MS pipe including connection etc as required. 36 Suplying, installation, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts bolts, washers, gasket conforming to IS 13095 of following sizes as required:150mm dia 37 Sub Head- 4: Fire Extinguisher 38 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 39 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 40 Providing and Fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceilling etc with proper clamps, hangers, cleats, anchor fasteners etc complete in all respect as directed by Engineer-In -Charge. 41 Sub Head- 5: Electrical Works (For Terrace Pump) 42 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 sq. mm 4 core 43 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring ofthe cable shall be properly connected with the earth as per direction of Engineer-Incharge. 10 sq. mm 4 core 44 Fabricating and Supply, Installing testing and commissioning of sheet steel clad floor mounting control panel having suitable size for control of 1 nos booster pump 9.3Kw/12.5HP each having suitable Incoming MCCb, incoming voltmeter with selector switch and fuses. Star Delta starter with hand reset overlaod cum single phase preventor type relay, ammeters to read current in one phase, alrm with reset push button which will automatically reset for the next cycle (As per technical specification) ( At terrace pump) 45 Supplying and Installing following sizes of Perforated pre-painted MS cable tray with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceilling with MS suspenders including bolts & nuts, painting suspender etc as required.150mm width x 50mm depth x 1.6mm thickness 46 Sub Head- 6: Fire Detection and Alarm System 47 Supplying, installation, testing & commissioning of main control and indicating panel made out of 16SWG MS sheet to accommodate the following items duly power coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.10 zone panel for fire alrm system (Agni/Alpha/Daksh/Equivalent)250 watt amplifier racks suitable vfor operation on 230 volt AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2Nos (one to act as standby)Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24V DC supplyconforming to IEC 268 for simplex mode of operation /communication suitable for 20Nos talk back unit-1 setAnnouncement control desk suitable for selection of different zones sewlectively and ON All Call switch with visual indication etc. complete as required -1 setAmplifier changeover switch for inter changing amplifier- 1 noMonitor panel for loud speeker complete with output selector, ON/OFF switch, fuse, visual indications etc, complete as required-1 NoGeoseneck microphone with stand and ON/OFF switch-1 no, Main ON/OFF switch, fuse indiaction lamps, DC and AC voltmeters and ammeters, terminal blocks etc, complete as required- 1 setBattery charger trickles cum boost to take complete load of fire alrm & PA system complete with all accessories including providing & fixing of 2 nos 12 volts, 60AH each sealed maintenance free batteries- 1 set 48 Supplying, installation, testing & commissioning of sector panel suitable for 4 Zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete as required. (Agni/Alpha/Daksh/Equivalent) 49 Supplying, installation, testing & commissioning of Smoke Detector with bulitin LED and mounting base complete with all connections etc as required.(System sensor/Apollo/Edwards/FST) 50 Supplying, installation, testing & commissioning of Heat Detector operating at 54c/57c with rate of rise cum fixed temperature (dual thermistor) with mounting base complete with all connections etc as required. (System sensor/Apollo/Edwards/FST) 51 Supplying, installation, testing & commissioning of response indicator on surface/ recessed MS box having two LED, metallic cover complete with all connections etc as required. 52 Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc as required. (Agni/Daksh/Equivalent) 53 Supplying, installation, testing & commissioning of fire alarm sounder with facility to make announcement, mounted in MS box (16SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc complete as required. (Agni/Alpha/Daksh) 54 Supplying, installation, testing & commissioning of talk back slave station in surface/recess suitable for operation on simplex mode complete with PTT knob & speaker/microphone enclosed in a MS (16 SWG)/ ABS box with break glass in front etc complete as required. 55 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable 600/1000 V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 56 Supplying and fixing of 25 mm dia steel conduit along with accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required. 57 Sub Head- 7: Public Address (PA) System 58 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player ( including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 59 Supplying, installation, testing & commissioning of 1.5/3/6 W metal box ceilling/wall speakers complete as required. 60 Supplying, installation, testing & commissioning of digital audio amplifier 50 watt, 25V rms operating at 240 Volt AC supply complete as required. 61 Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required 62 Supplying and drawing of cable Fire Retardant Pvc insulated copper conductor cable in existing surface/ recessed steel conduit speaker cable three pair, 2 core, 1.5 sqmm including connections and interconnections etc as required. 63 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the vwall and making good the same in case of recessed conduit as required. 64 25 mm dia PVC conduit 65 GST 18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
Uttar Pradesh View Result →
36.
Housing Urban and Rular Development #9443251 Technical Bid
Tender For Development Of Tourism Office At Distt. Deoria, 1 TOURIST FACILITATION CENTER (Civil) 2 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. Excavation by Manual means [Special tools] 3 From Lvl. 0.00 To 1.50 Mtr 4 Filling of carted earth. 5 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8Km from the site of work and including watering, dressing etc. Rate to include cost of all materials, labour, T&P etc. required for proper completion the work. 6 Concrete with 4cm. Gauge approved stone ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour, tools and plants etc. required for proper completion the work. 7 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete 8 (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 9 (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. 10 Providing & laying in position machine batched and machine. Mixed design mix M-25 grade cement concrete for reinforcement cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying excludingthe cost of centering, shuttering , finishing and but excluding reinforcement , including admixtures in recommended proportion as per IS : 9103 to acclerate, retarder for setting of concrete/ improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note :- Cement content considered in this item @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately.R.C.C. work Upto plinth Lvl.(M-25) 11 R.C.C. work in Footing 12 R.C.C. work in Column 13 R.C.C. work in Beam 14 Providing & laying in position machine batched and machine. Mixed design mix M-25 grade cement concrete for reinforcement cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying excludingthe cost of centering, shuttering , finishing and but excluding reinforcement , including admixtures in recommended proportion as per IS : 9103 to acclerate, retarder for setting of concrete/ improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note :- Cement content considered in this item @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately.R.C.C. work Upto Above Lvl.(M-25) 15 R.C.C. work in Lintel 16 R.C.C. work in Slab 17 R.C.C. work in Beam 18 R.C.C. work in Column 19 M-150 brick work in 1:6 cement and coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour, T & P etc reqiored for proper completion of the work. 20 Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5x 4x3having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall 21 Providing machine made Wire Cut Bricks in Arches where edges are sharp and borders are straight and Size of8.5x 4x3having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall 22 Extra for forming cavity 42 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 460 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design. 23 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand) 24 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 25 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 26 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 27 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 28 Upto Plinth Lvl. 29 Above Plinth Lvl. 30 15mm thick cement plaster on rough side of single or half brick wall of mix in 1:4 (cement & coarse sand) in plinth. 31 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth. (1) 1 cement : 6 coarse sand 32 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 sand 33 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 34 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily..Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm 35 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm 36 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily..Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 37 Providing and fixing three-layer construction, wooden plank/engineered Wood size185—200 mmX 2000-2426 mmof 3 strip oak with a total thickness of 15 mm and a wear layer thickness of 3.5mm should be resandable up to 2 to 3 times. Surface Treatment: Matt/ Ultra matt Lacquer, Core: Pine/ Spruce/ Alder. Joint: Woodloc 5S, fifth-generation locking system, Moisture Content as per EN 13183: 7%, Reaction to fire as per EN13501-2:1 Dfl- s1CARB 2 compliant, Biological Durability as per EN350-2 Class1 confirming to strict quality and environment norms. It should be certified by PEFC, FSC, Blue Angel, and Real Wood.Matching Accessories like skirting & profile with,. Installation should be done by a trained and authorized team on Zero level of the hard surface .Make-Kahrs, Armstrong 38 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick 39 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 40 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 41 Granite of any colour and shade (Area of slab upto 0.50 sqm) 42 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of anysize as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 43 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoiningwalls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. 44 (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 45 Supply & fixing of flush doors commercial quality conforming to IS : 2202 Part I (1983) including fixing of wooden cleats & stoppers & including fixing & adjustment of hinges, bolts locks, handles, springs & other fittings but excluding their supply & including painting with two coats of black Japan paint on all iron fitting. Fitting with necessary screws to be supplied departmentally. 46 35 mm thick. 47 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 48 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 49 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 50 In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works 51 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 52 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDMgasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) 53 Note: For uPVC frame, sash and mullion extruded profilesminus 5%tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 54 Using R2 series with frame (40 mm & above) x (40 mm & above) & sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). 55 Float glass panes 56 5.0 mm thick glass panes (weight not lessthan 12.50 kg/sqm). 57 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 58 Providing and fixing to existing door frames. 59 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelleddoor shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturatedpolyester resin, moulded to 3 mm thick FRP laminate forforming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 60 Supply and fix powder coated Aluminium louvered door double leaves type overall size as per drawing for maintenance opening in the service area ,with all required fixing angles, bolts, welding including1’ wide Aluminium Louvers of approved shade in door Including allaccessories required for installation of the louvers, painting and priming and all required as per drawings and Engineer instructions in charge 61 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give aneven shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 62 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 63 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 64 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats. (For Internal wall surface & ceiling) (Asian Paint or equivalent) 65 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 66 Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 67 Providing & fixing stainless steel sliding door bolts ISI marked to required colour or shade with nuts and screws etc complete. 68 (a) 300mm x 16mm 69 P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc. 70 (a) 250 mm x 10mm 71 (b) 200 mm x 10mm 72 Providing & fixing stainless steel handles ISI marked to required colour or shade with necessary screws etc. complete. 73 125 mm 74 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 75 Providing & laying of light cinder filling under floor of toilets & other sunken roofs. 76 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 77 Construction of drain along with apron. 78 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). for ACP & STRUCTURAL GLAZING WORK 79 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: 80 a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: 81 b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. 82 c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. 83 d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. 84 Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” 85 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. 86 The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm 87 (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 88 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. 89 Providing & fixing mineral fibre false ceiling tiles at all height of size 595 x 595 mm. of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85% Thermal Conductivity k = 0.052- 0.057 w/m K, Fire performance as per (Bs 476 pt - 6 & 7) in true horizontal level suspended on interlocking T-Grid of hot dipped all around galvanized iron secion of 0.33mm thick (galvanized @ 120 gsm) 90 comprising of main T-Runners of 15x32mm of length 3000mm, cross T of size 15x32mm of length 1200mm and secondary intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600x600mm suspended from ceiling using galvanized mild steel item (galvanised @ 80 gsm) 50mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2mm, spaced at 1200mm centre to 91 centre along main T. The system should rest on periphery walls/ partitions with the help of G.I. perimeter wall angle of size 24x24x3000mm made of 0.40mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyster baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 92 With 16 mm thick beveled tegular mineral fibre false ceiling tile 93 Centering and shuttering including strutting, propping etc. and removal of form for 94 Foundations, footings, bases of columns, etc. for massconcrete 95 Suspended floors, roofs, landings, balconies and accessplatform 96 Lintels, beams, plinth beams, girders, bressumers andcantilevers 97 Columns, Pillars, Piers, Abutments, Posts and Struts 98 Providing, Suppling & fixing of cultural Terracotta tile mural work of 20mm thick inspired from the extraction of Ramayana and the Local Tangible context as per architect incharge. 99 FIRE FIGHTING WORKS 100 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS) 101 150 mm dia. 102 100 mm dia. 103 80 mm dia. 104 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 105 150 mm dia. 106 100 mm dia. 107 80 mm dia. 108 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 109 150 mm dia. 110 100 mm dia. 111 80 mm dia. 112 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required : 113 2 way - 100 mm dia M.S. Pipe (Siamese Connection) 114 4 way - 150 mm dia M.S. Pipe 115 TOTAL OF SUBHEAD-I 116 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in allrespects, as required: (Terrace Pump) 117 (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 118 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. 119 (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. 120 (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 121 900 lpm at 35 m Head 122 450 lpm at 35 m Head 123 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) 124 Providing & fixing of start/stop push buttons including complete connection etc. as required. (for terrace booster pump) 125 Providing and fixing in position the industrial type pressuregauges with gun metal / brass valves complete as required (for terrace booster pump) 126 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 127 150 mm dia. 128 100 mm dia. 129 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 130 150 mm dia. 131 100 mm dia. 132 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 133 80 mm nominal bore 134 100 mm nominal bore 135 150 mm nominal bore 136 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 137 Single headed Gunmetal 138 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 139 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 140 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 141 40 m 142 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 143 Gun metal 144 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 145 Gun metal 146 Providingandfixing standard fire mans axe with heavy duty insulated rubber handle. 147 Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door:900mm Wide & 1500mm Height) 148 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 149 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 150 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 151 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 152 Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. 153 TOTAL OF SUBHEAD-III 154 FIRE FIGHTING PANEL 155 Fabricating & Supply, installing, testing and commissioning ofsheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 9.3 KW/12.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. Star delta starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle.(As per the Technical Specifications)(At Terrace floor) 156 Fabricating & Supply, installing, testing and commissioning ofsheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 5.5 KW/7.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. DOL Starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle.(As per the Technical Specifications)(At Terrace floor) 157 Supply, installation , testing & commissioning of XLPE insulated and PVC outer sheathed Aluminium conductor armoured cable of 1.1 KV grade confirming to IS : 7098:1988 (with upto date amendments) of following sizes. 158 3 Core, X 10 sqmm. 159 3 Core, X 6 sqmm. 160 Supplying and making end termination with brass compression gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/ XLPE Al.conductor cables of 1.1 KV grade as required. 161 3 Core, X 10 sqmm. 162 3 Core, X 6 sqmm. 163 Supplying and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathedarmoured cable between various sensors and system controller/starter etc.in pump house & out side on surface/existing cable tray complete with connections at both end with glands etc.as required 164 4 x 2.5 sq.mm 165 2 x 2.5 sq.mm 166 Supplying and installing following size of perforated pre-painted M.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 167 150 mm width x 50mm depth x 1.6 mm thickness. 168 FIRE ALARM SERVICES 169 Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 170 6 zone panel for fire alarm system 171 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. 172 Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. 173 Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. 174 Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. 175 Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. 176 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 177 4-Zone Panel. 178 6-Zone Panel. 179 10-Zone Panel. 180 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. 181 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 182 Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 183 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete asrequired. 184 Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. 185 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 186 INTERNAL W/S & SANITATION WORK 187 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 188 W.C. pan with ISI marked white solid plastic seat and lid 189 Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete. 190 Providing & fixing toilet paper holder 191 C.P. brass 192 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 193 Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. 194 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 195 White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap 196 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 197 (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 198 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 199 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 200 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 201 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 202 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) 203 15 mm nominal bore 204 Providing and fixing uplasticised PVC connection pipe with brass unions : 205 45 cm length 206 15 mm nominal bore 207 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 208 100 mm diameter 209 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 210 15 mm nominal bore 211 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 212 15 mm nominal dia 213 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 214 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. 215 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 216 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required 217 Kitchen sink with drain board 218 510x1040 mm bowl depth 200 mm 219 Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete 220 Flexible Pipe 221 32mm Dia 222 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 223 15mm nominal bore 224 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 225 15mm nominal bore 226 Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. 227 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) 228 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. 229 Granite Stone of approved shade 230 Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc. 231 Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. 232 Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. 233 Capacity 25 Liters 234 TOTAL OF SUBHEAD-I 235 SUB HEAD-II-WATER SUPPLY 236 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 237 Concealed work, including cutting chases and making good the walls etc. 238 For Internal Toilet 239 15 mm nominal outer dia Pipes 240 20 mm nominal outer dia Pipes 241 25 mm nominal outer dia Pipes 242 32 mm nominal outer dia Pipes 243 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 244 Internal work - Exposed on wall 245 20 mm nominal bore 246 25 mm nominal bore 247 32 mm nominal bore 248 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 249 Terrace loop & Tank Filling Pipe 250 40 mm nominal bore 251 50 mm nominal bore 252 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 253 40mm diameter pipe 254 50mm diameter pipe 255 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 256 40mm diameter pipe 257 50mm diameter pipe 258 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 259 For vertical pipe connection with terrace ringmain 260 20 mm nominal bore 261 25mm nominal bore 262 32mm nominal bore 263 40mm nominal bore 264 50mm nominal bore 265 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 266 25 to 40 mm nominal bore 267 50 to 80 mm nominal bore 268 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. 269 40 mm nominal bore, 206 mm long, weighing not less than 690 gms 270 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 271 Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral orequivalent approved complete in all respect as directed by Engineer-in-charge. 272 15mm dia (9 mm thickness) 273 20mm dia (9 mm thickness) 274 Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:- 275 Lehry Make Automatic OHT Level Control System Consist of Following Items 276 1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch. 277 40mm 278 Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 279 25mm dia. 280 32mm dia. 281 40mm dia. 282 50mm dia. 283 65mm dia. 284 80mm dia. 285 100mm dia. 286 150mm dia. 287 200mm dia. 288 250mm dia. 289 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 290 110 mm dia (for rain water) 291 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. 292 Single Push Fit Coupler 293 110 mm dia 294 Single tee with door 295 110x110x110 mm 296 Plain bend 87.5 deg 297 110 mm dia 298 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 299 110 mm dia 300 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 301 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 302 All kind of soil 303 Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 304 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 305 100mm dia SWpipe 306 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 307 Internal Toilet (Soil & Waste Pipe) 308 75 mm 309 110 mm 310 Exposed on Wall (Soil & Waste Pipe) 311 110 mm 312 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 313 Bend without door (45°) 314 75mm 315 110mm 316 Bend without door (87.5°) 317 75mm bend 318 110mm 319 Y Fitting without door 320 75mm 321 110mm 322 Single Tee without door 323 75mm 324 110 mm 325 Single Tee with door 326 75mm 327 110 mm 328 Bend with door (87.5°) 329 75mm 330 110 mm 331 Clean Out Plug (COP) 332 75mm 333 110 mm 334 Reduced Y Fitting without door 335 110mm x 75mm 336 Reduced Tee with door 337 110mm x 75mm 338 Coupler 339 75mm 340 110mm 341 Vent Cowl 342 110mm 343 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. 344 For Wash basin & Urinal 345 32mm dia. Pipe 346 50mm dia. pipe 347 Elbow (45°) 348 32mm 349 50mm 350 Elbow (90°) 351 32mm 352 50mm 353 T fitting 354 32mm 355 50mm 356 Coupler 357 32mm 358 50mm 359 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 360 110mm x 75mm x 50mm/40mm (Toilet) 361 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 362 110mm x 75mm (Toilet & Kitchen) 363 Providing and fixing PTMT grating of approved quality and colour. 364 Rectangular type with openable circular lid 365 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) 366 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 367 150 x 100mm size P-type 368 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 369 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 370 100 mm diameter 371 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 372 All kind of soil 373 Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 374 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 375 100mm dia SWpipe 376 INTERNAL ELECTRIFICATION WORKS 377 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 378 Group - B 379 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 380 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required 381 Group -A 382 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 383 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 384 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 385 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 386 2 X 6 sq. mm + 1 X 4 sq. mm earth wire 387 2 x 10 sq.mm + 1 x 6sq.mm. earth wire 388 2 x 16 sq.mm + 1 x 6sq.mm. earth wire 389 4 x 6 sq.mm + 2 x 6 sq.mm. earth wire 390 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire 391 4 x 16 sq.mm + 2 x 6sq.mm. earth wire 392 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. 393 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 394 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 395 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 396 Wiring for light/ power plug plug with 2 X 4 sq. mm FRLC PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FRLC PVC insulated copper conductor single core cable for loop earthing as required 397 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 398 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required 399 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 400 5/6 A switch 401 3 pin 5/6 A socket outlet 402 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 403 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 404 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box forceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding,top lid shall be screwed into the cast iron/ M.S. sheet box by means of3.3 mm dia round headed screws, one lock at the corners. Clamp shallbe made of 12 mm dia M.S. bar bent to shape as per standard drawing. 405 Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) 406 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required 407 Upto 450 mm sweep 408 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 409 Supply of surface/Recessed mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 410 Supply of surface mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 411 Supply of LED 4ft 2x20W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 42W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor Make Jaguar LUNI01X220XW, Philips / BAJAJ or Eq. 412 Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. 413 Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 414 Supply ofSurface mounting round 12 Watt 15 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect 415 Supply of Surface mounting square 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 416 Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.Including connection with 1.5 sqmm FRLS PVC insulated copper conductor as required. 417 Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. 418 Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, 419 Supplying and fixing brass batten/ angle holder including connection etc. as required. 420 Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. 421 Supplying of 9 Watt Decorative LED Wall Light complete in all respect. 422 MACTY SURFACE DOWNLIGHT Divinity Sarface Macty Up and Down Light Outdoor Fixture (IP-65) Optical system=LensWattage=2x10WLumen=1600lmCCT=3000KCRI>80Beam Angle=12° /24° / 36° / 60°Driver=Non Dimmable Material=Aluminium Dia castingStandard Lifetime=L70Minimum 50000 HoursFinish=BlackDimension=Dia=100mm,H=100mm 423 Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver andapable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9 . Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 424 Supply and Fixing 24 Wattage Burial UNIIn Ground- Burial ip68 waterproof BBP343 LED2400/1800/WW 24W/18W 20D 100-240V (Philips/Siems/or Equivalent) 425 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan 426 Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect. 427 Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 428 300mm EXHAUST FAN 429 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 430 63 A,25KA,FP MCCB 431 100 A,30KA,FPMCCB 432 125 A,36KA,FPMCCB 433 160 A,25KA,FP MCCB 434 200 A, 36KA,FPMCCB 435 Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 436 6 Way Double Door 437 8 way, Double door 438 12 way, Double Door 439 16 way, Double Door 440 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 441 4 Way Double door 442 6 way Double door 443 8 way Double door 444 12 way Double door 445 Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 446 4 way (4 + 12), Double door 447 8 way (4 + 24), Double door 448 Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required. 449 Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 450 40 amps SP MCB 451 40 amps DP MCB 452 63 amps DP MCB 453 40 amps TP MCB 454 63 amps TP MCB 455 40 amps 4P MCB 456 63 amps 4P MCB 457 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 458 40 amps 459 63 amps 460 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 461 40 amps 462 63 amps 463 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 464 25 amps 465 40 amps 466 63 amps 467 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 468 Single pole 469 Double pole 470 Triple pole 471 Triple pole and neutral 472 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 473 Supplying and fixing 1P LCD Energy Meter 5-30A with BOX 474 Supplying and fixing 3Ph 4 W kWh Dir base mtg 240V 10- 60 A Energy Meter 475 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 476 Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V C curve DP MCB complete withconnections, testing and commissioning etc. as required. 477 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 478 90 mm dia (OD-90 mm & ID-76 mm nominal) 479 Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCBs to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. 480 The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. 481 The minimum clearances between bus bars shall be as follows : 482 Phase to phase - minimum 20mm 483 Phase to neutral-minimum 15mm 484 MAIN PANEL 485 Same as above item but following mountings. 486 INCOMER:- 487 One (1) No 160 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity with thermal Magnetic release 488 Metering : 489 1 Set of CTs one of 160/ 5Amp ratio for Multifunction Meter 490 One (1) Set of Phase Indication Lamp. 491 Bus Bar : 492 One (1) No.200 Amp.TPN aluminimum bus bar of suitable length. 493 Outgoing : 494 Phase indication lamps on each outgoing to be provided. 495 40 Amps 4P MCCB of 25KA (Ics=Icu)Breaking Capacity- 6 No 496 63 Amps 4P MCCB of 25KA (Ics=Icu)Breaking Capacity- 2 No 497 10 Amps DP MCB of 10KA (Ics=Icu)Breaking Capacity- 2 No 498 2 Nos.Space & Spare 499 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each 500 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. 501 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 502 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 503 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 504 Providing and Fixing 6 SWG dia G.I. Wire on surface or in recess for connection etc. as required. 505 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 506 Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. 507 Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: 508 2 Pair (4 core) 509 Providing, laying, connecting and testing of multi-core telephone unarmoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe. 510 100 Pair telephone cable 511 20 Pair telephone cable 512 10 Pair telephone cable 513 5 Pair telephone cable 514 Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. 515 5 Pair tag block 516 10 pair tag block 517 20 pair tag block 518 100 pair tag block 519 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 520 20mm dia PVC conduit 521 25mm dia PVC conduit 522 32mm dia PVC conduit 523 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 524 1 or 2 Module (75mmX75mm) 525 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 526 Telephone socket outlet 527 TV antenna socket outlet 528 Bell Push 529 RJ-45 Data Socket outlet 530 Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. 531 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 532 1 run of cable 533 Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe. 534 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 535 Up to 35 sq.mm. 536 Above 35 sq.mm. and up to 95 sq.mm. 537 Above 95 sq.mm. and upto 185 sq.mm. 538 Above 185 sq.mm. and up to 400 sq.mm. 539 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, rotective covering and refilling the trench etc as required 540 Up to 35 sq.mm. 541 Above 35 sq.mm. and up to 95 sq.mm. 542 Above 95 sq.mm. and upto 185 sq.mm. 543 Above 185 sq.mm. and up to 400 sq.mm. 544 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. 545 Up to 35 sq.mm. 546 Above 35 sq.mm. and up to 95 sq.mm. 547 Above 95 sq.mm. and upto 185 sq.mm. 548 Above 185 sq.mm. and up to 400 sq.mm. 549 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. 550 Up to 35 sq.mm. 551 Above 35 sq.mm. and up to 95 sq.mm. 552 Above 95 sq.mm. and upto 185 sq.mm. 553 Above 185 sq.mm. and up to 400 sq.mm. 554 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required 555 Up to 35 sq.mm. 556 Above 35 sq.mm. and up to 95 sq.mm. 557 Above 95 sq.mm. and upto 185 sq.mm. 558 Above 185 sq.mm. and up to 400 sq.mm. 559 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. 560 Up to 35 sq.mm. 561 Above 35 sq.mm. and up to 95 sq.mm. 562 Above 95 sq.mm. and upto 185 sq.mm. 563 Above 185 sq.mm. and up to 400 sq.mm. 564 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required 565 Upto 35 sq. mm (clamped with 1mm thick saddle 566 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp 567 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp 568 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) 569 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 570 Upto 35 sq. mm (clamped with 1mm thick saddle) 571 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 572 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 573 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) 574 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 575 3.5 x 400 sq.mm. 576 3.5 x 300 sq.mm. 577 3.5 x 240 sq.mm. 578 3.5 x 185 sq.mm 579 3.5 x 150 sq.mm 580 3.5 x 120 sq.mm 581 3.5 x 95 sq.mm 582 3.5 x 70 sq.mm 583 3.5 x 50 sq.mm 584 3.5 x 35 sq.mm 585 3.5 x 25 sq.mm. 586 4 x 25 sq.mm 587 4 x 16 sq.mm 588 4 x 10 sq.mm 589 4 x 6 sq.mm 590 2 x 16 sq.mm, 591 2 x 10 sq.mm, 592 2 x 6 sq.mm, 593 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 594 2 X 6 sq. mm (19mm) 595 2 X 10 sq. mm (19mm) 596 2 X 16 sq. mm (22mm) 597 3½ X 25 sq. mm (28mm) 598 3½ X 35 sq. mm (32mm) 599 3½ X 50 sq. mm (35mm) 600 3½ X 70 sq. mm (38mm) 601 3½ X 95 sq. mm (45mm) 602 3½ X 120 sq. mm (45mm) 603 3½ X 150 sq. mm (50mm) 604 3½ X 185 sq. mm (57mm) 605 3½ X 225 sq. mm (62mm) 606 3½ X 240 sq. mm (62mm) 607 3½ X 300 sq. mm (70mm) 608 3½ X 400 sq. mm (82mm) 609 4 X 10 sq. mm (25mm) 610 4 X 16 sq. mm (28mm) 611 Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required 612 100 mm dia 613 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 614 100mm dia 615 150 mm dia 616 250 mm dia 617 300 mm dia 618 Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. 619 90 mm dia (OD-90 mm & ID-76 mm nominal) 620 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 621 100 mm wide x 50 mm depth x 1.6 mm thickness. 622 150 mm wide x 50 mm depth x 1.6 mm thickness. 623 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 624 100 mm wide x 50 mm depth x 1.6 mm thickness. 625 150 mm wide x 50 mm depth x 1.6 mm thickness. 626 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray Tee (galvanisation not less than 50microns) with perforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceilingwith G.I. suspenders including G.I. bolts & nuts, etc. as required. 627 100 mm wide x 50 mm depth x 1.6 mm thickness. 628 EXTERNAL SEWERAGE & WATER SUPPLY SYSTEM 629 COST OF SEWERAGE WORKS 630 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 631 up to 1.50 m depth 632 Pipes 80 mm to 300 mmdiameter 633 1.50 m to 3.00 m depth 634 Pipes 80 mm to 300 mmdiameter 635 Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) 636 Depth not exceeding 1.5 meter 637 Depth 1.5 to3.00meter 638 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 639 150 mm.dia. RCCPipes 640 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 641 150 mm.dia. RCCPipes 642 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. 643 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). 644 With common burnt clay FPS (non modular) bricks of class designation 75 645 (i) For Sewer Line 646 Extra for depth for manholes: 647 Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 648 Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). 649 With common burnt clay FPS (non modular) bricks of class designation 75 650 (i) For Sewer Line 651 Extra for depth for manholes: 652 Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 653 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 654 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 655 80mm nominal bore. 656 65mm nominal bore. 657 50mm nominal bore. 658 40mm nominal bore. 659 32mm nominal bore. 660 25mm nominal bore. 661 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 662 80mm nominal bore. 663 65mm nominal bore. 664 50mm nominal bore. 665 40mm nominal bore. 666 32mm nominal bore. 667 25mm nominal bore. 668 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (horizontal) 669 80mm nominal bore. 670 65mm nominal bore. 671 50mm nominal bore. 672 40mm nominal bore. 673 32mm nominal bore. 674 25mm nominal bore. 675 Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 676 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 677 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : 678 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 679 EXTERNAL SEWERAGE SYSTEM (SEPTIC TANK) 680 SEPTIC TANK & SOAK PIT 681 Size :- Length = 5.0 M. Width = 2.0M Total Depth =3.00M 682 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. 683 In all kind of soil upto 1.5m depth 684 In all kind of soil upto 1.5m to 3.0m. depth 685 In all kind of soil upto 3.0m to 4.5m. depth 686 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) 687 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 688 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 689 Suspended floors, roofs, landings, balconies and access platform. 690 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 691 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) 692 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 693 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 694 Providing & fixing 75mm dia vent pipes. 695 Providing & fixing of 75mm dia cast iron terminal guard. 696 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 697 M.D. -10- Circular shape 500mm internal diameter 698 M.D. -2.5- Circular shape 450mm internal diameter 699 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. 700 With F.P.S. bricks 701 RAIN WATER HARVESTING WORKS 702 RECHARGE PITS 703 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. 704 In all kind of soil upto 1.5m depth 705 In all kind of soil upto 1.5m to 3.0m. depth 706 In all kind of soil upto 3.0m to 4.5m. depth 707 In all kind of soil upto 4.5 m to 6.0m. depth 708 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 709 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 710 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 711 Suspended floors, roofs, landings, balconies and access platform. 712 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 713 12mm cement plaster on rough side of single or half brick wall mix 714 1:3 (1 cement : 3 Coarse sand) 715 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: 716 With 20x20mm square bar 717 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 718 M.D. -10- Circular shape 500mm internal diameter 719 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 720 Drilling of 300mm dia bore hole manually. 721 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 722 150 mm nominal size dia 723 Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge. 724 Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge. 725 Supplying, filling, spreading & leveling coarse sand of size range 1.5mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge. 726 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge. 727 DESILTING CHAMBER 728 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. 729 In all kind of soil upto 1.5m depth 730 In all kind of soil upto 1.5m to 3.0m. depth 731 Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. 732 Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 733 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 734 Suspended floors, roofs, landings, balconies and access platform. 735 Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 736 15mm cement plaster on rough side of single or half brick wall mix 737 1:3 (1 cement : 3 Coarse sand) 738 Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: 739 With 20x20mm square bar 740 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 741 M.D. -10- Circular shape 500mm internal diameter 742 COST OF EACH RAIN WATER HARVESTING 743 TOTAL NO. OF RAIN WATER HARVESTING 744 TOTAL COST OF RAIN WATER HARVESTING 745 DRAINAGE NETWORK 746 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 747 up to 1.50 m depth 748 Pipes 80 mm to 300 mmdiameter 749 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 750 150 mm.dia. RCCPipes 751 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 752 150 mm. dia. 753 Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks 754 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: 755 Drain 300 wide average.Depth 45 cm with R.C.C. slab 756 INTERLOCKING PATHWAY (283 Sqm) 757 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil (D.S.R. 2.8.1) 758 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (D.S.R. 4.1.8) 759 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 760 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 761 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 762 TRIMIXING FOR PARKING AREA 184.98 SQM 763 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil 764 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 765 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finishedwith screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specificationsand directions of Engineer-in-charge. Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately (DSR-16.75) 766 Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade A sealing compound. DSR- 16.46.1 767 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.[ DSR 5.22.6 ] 768 BORING & SUBMERSIBLE PUMP 769 Drilling of 200 mm dia bore hole. 770 Supply of 125 mm dia MSpipe as per IS1239 771 Supply of 125 mm dia slotted MSpipe 772 Supply and fixing of nylon jali around the slotted pipes complete as required. 773 Providing and packing of coarse sand / pea gravel around the pipe. 774 Transport of boring tools other required equipements and installation at site. 775 Supply of submersible pump (3.7KW/5.0 HP) of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete. 776 Providing 3 core PVC insulated submersible cable. (from pump panel to submersible pump) 777 Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level) 778 Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. 779 Lowering of 125 mm dia MS pipe in bore hole including cutting,jointing etc complete. 780 Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. 781 Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 core submersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the work. 782 Testing and development of tube well. 783 HORTICULTURE 784 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 785 Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 786 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm 787 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 788 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 789 Rough dressing the trenched ground including breaking the clods. 790 Fine dressing the ground 791 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and the good earth shall be paid for separately). 792 Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 793 Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge 794 With grass Turf 795 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 796 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep 797 Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). 798 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water) 799 Providing and stacking of Acacia auriculiformis of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 800 Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 801 Providing and stacking of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 802 Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge. 803 Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge 804 Providing and stacking of Fishtail palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 805 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35 - 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 806 Providing and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur)of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. 807 Providing and stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35 cm as per direction of the officer-in-charge. 808 Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 809 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 810 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 811 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 812 Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 813 Providing and stacking of Ficus benjamina (green) of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the officer-in-charge. 814 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 815 GST Extra As per Applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
37.
Power #9381169 Technical Bid
Tender For System Augmentation / Strengthening Works In Jhansi Nagar Under Ee Eudd I Jhs On Semi Turnkey Basis-2 Local / De-Centralised Items- All Items Will Be Supplied And Errected By Firm. 3 Al Lug 120 Sq Mm 4 Al Lug 150 Sqmm 5 Al Lug 240 Sq Mm 6 Al. Lug 400 Sqmm 7 Hs 11 Kv Cable Jointing Kit ( 3X70 ) Sqmm O / D 8 Hs 11 Kv Cable Jointing Kit ( 3X120 ) Sqmm 0 / D 9 Hs 11 Kv Cable Jointing Kit ( 3X185 ) Sqmm S / T 10 Hs 11 Kv Cable Jointing Kit ( 3X300 ) Sqmm I / D 11 Hs 11 Kv Cable Jointing Kit ( 3X300 ) Sqmm O / D 12 Hs 33 Kv Cable Jointing Kit ( 3X50 ) Sqmm O / D 13 Hs 33 Kv Cable Jointing Kit ( 3X300 ) Sqmm O / D 14 Straight Through 3X300sqmm Xlpe Cable 33 Kv 15 Straight Through 3X185sqmm Xlpe Cable 11 Kv 16 Bolt Nut And Washer All Size 17 Pg Clamps 16 Sqmm - 50 Sqmm ( For Line To Line Jumpering ) 18 Stone Pad 19 Pg Clamp 16 Sqmm-50 Sqmm ( For Line To Line Jumpering ) 20 Cu. L-Clamp 21 24 Volt Battery And Battery Charger With Cabinet 22 Ht Tape 23 Danger Board With Clamps & Bolts 24 Barbed Wire Gi 25 Gi Pipe 6 Dia 26 Hdpe Pipe 6 Dia For Cable Laying By Hdd. 27 Pipe Joints For Jointing The Pipe 28 Cable Route & Cable Marker 29 33 Kv Bushing For Power Transformer 30 11 Kv Bushing For Power Transformer 31 11 Kv Neutral Bushing Complete 32 Winding Temperature Indicator 33 Oil Temperature Indicator 34 Control Cable 35 Switch Gear Mimic Diagram In Red Colour 36 11 Kv Over Current And Earth Fault Relays 37 33 Kv Over Current And Earth Fault Relays 38 Braething Mask For Fire Fighting Within The Substation 39 20 Kv Insulating Gloves 40 Suitable Insulated Stool 41 33 Kv And 11 Kv Volatge Indicator Rod Of The Telescopic Type 42 Rechargeable Torch Light 43 Instruction Against Electrical Shocks And Artificial Breathing In Hindi Or English Language 44 Complete Set Of Safety Regulation Signs For Open Circuit , Danger Zone Etc In Hindi Language 45 Drawing And Instruction Books / Chart 46 Silica Gel 47 Insulated Screw Driver 48 Pliers 49 Hacksaw 50 Cable Cutter 51 Spanner 52 Volateg Tester 53 Safety Knife 54 Hex Keys 55 Claw Hammer 56 Chisel 57 Electrician Tool Kit 58 5Kv 10Kv 15Kv High Voltage Insulation Resistance Tester / Megger 59 Trolley With Wheel And All Required Accessories 60 Wire Mesh Fencing With Door Complete 61 4 Core Lt Mcb With Box - Lt Incoming Protection Panel With Metering Equipment ( Type-A 100 To 500 Amp 4Pole Mcb With Box / Lt Protection Panel ) 62 33 Kv Lightning Arrestor 63 Plinth Complete 64 Sundry Stores 65 Road Restoration Charges For Kachha Footpath Side 66 Dismentalling Of Old And Used Line Material As Per Nature Of Work 67 Back Carriage Of Receive Back Material From Concerne Site To Esc Hansari Or As Per Direction By Inchareg 68 Concreting Of Poles 69 Painting Of Pole With Red Oxide / Silver Oxide Paint Of Two Coat ( Paint Provided By Contractor ) 70 Number Marking On Pole By Paint, Yellow Base Will Be Prepared And Number Shall Be Written By Black Paint ( Paint Provided By Contractor ) 71 Dismentalling Of Old And Used Stp / Pcc 72 Safe Loading, Carriage And Unloading Of Pcc / St Pole 13 / 11 / 09 / 8.5 Mtr. Long From Esc Hasari Store / Je Store To Work Site. 73 Safe Loading, Carriage & Unloading Of Line Material ( I.E. Acsr Conductor, 11Kv Cable. Ab Cable, Other Cables, Ms Material, Clamps Etc ) From Esc Hasari Store / Je Store To Work Site. 74 Construction Of Double Pole Structure With St Pole 11 Mtr Long Sp-55 Including Fixing Of All Accessories Complete With Concreting & Plinth For 25 / 63 / 100 Kva, 11 / 0.4 Kv Pole Mounted Sub-Station. 75 Construction Of Double Pole Structure With St Pole 11 Mtr Long Sp-55 Including Fixing Of All Accessories Complete With Concreting & Plinth For 250 / 400 Kva, 11 / 0.4 Kv Plinth Mounted Sub-Station. 76 Installation Of 25 / 63 / 100 Kva Tf On Dp With Assembling Of All Acceseries 77 Installation Of 250 / 400 Kva Tf With Assembling Of All Acceseries 78 Earthing Of Pole By Earthing Rod, Gi Wire Etc. Complete 79 Painting Of Pole With Red Oxide Paint & Aluminium Paint And Numbering Of Pole With Black Over Yellow Base. 80 Laying Of 11 Kv Cable Of Size 3X185 / 120 / 70 / 35 Sq Mm 11 Kv As Per Site Requirement 81 Digging Of Horizontal Boring Under The Highway / Railway Track For Fixing Of Hdpe Pipe For Laying Of 11 Kv Cable As Per Site Requirement. 82 Digging Of Cable Trench And Cover With First Class Bricks Protection And Filling The River Sand Including Back Filling By Sandfor Laying Of 11 Kv Cable With Fixing Of Hdpe / Gi Pipe ( As Per Need ) And Cable Route Marker Also Complete. 83 Filling Of 11 Kv 3Cx185 / 120 / 70 Sqmm Cable Jointing Kit O / D / I / D Type 84 Chemical Earthing . 85 Chemical Earthing Of 33 Kv Ug Cable 86 Supply Of Gi Pipe 6 Dia If Not Available In Store 87 Supply Of Hdpe Pipe ( Pe63, 10Kg / Cm3, Is 4984:1995 ) 6 Dia Or Equivalent If Not Available In Store 88 Supply & Fixing Of Pipe Joints If Not Available In Store 89 Supply & Fixing Of Cable Route Marker If Not Available In Store 90 Trimming & Chopping Of Tree Branches Asper Site Requirement 91 Dismantalling Of St / Rail / Joist / Pcc Pole Of Lt Line 92 Dismantalling Of Line Material ( Acsr Conductor, Ab Cable, Cross Arms, Various Clamps Etc ) Of Ht 11 Kv / Lt Line. 93 Loading, Carriage & Unloading Of Existing Poles & Line Material Scrap From Site To Store. 94 Extra R&M Work On Existing Network I.E Petroling, Augomentaion, Horizenton & Vertical Cleareance As Per Ie Rules And As Per Requrment Of Side Condition. 95 Excavation Work Of Cable Trench 96 Centralised Items - All Materials Will Be Provided By Store. Contractor Quote Their Errection Rate Only. 97 Lt Xlpe Cable Al. 3.5X150 Sqmm 98 Lt Xlpe Cable Al. 1X240 Sqmm 99 Lt Xlpe Cable Al. 1X400 Sqmm 100 Cable Al. 3X70 Sqmm Xlpe 11 Kv 101 Cable Al. 3X120 Sqmm Xlpe 11 Kv 102 Cable Al. 3X185 Sqmm Xlpe 11 Kv 103 Cable Al. 3X300 Sqmm Xlpe 33 Kv 104 Cable Lt Abc ( 3X50+1X35+1X16 ) Sqmm 105 A.B. Cable ( 3*95+1*70+1*16 ) Sq Mm 106 A.B. Cable ( 3*120+1*95+1*16 ) Sq Mm 107 Stp 11M-Is410 Sp-55 ( For Lt New / Replace Line 108 Stp 13M-Is410 Sp-55 ( For Lt New / Replace Line 109 Acsr Weasel Conductor 110 Phase Wire Acsr Dog Conductor 111 Acsr Panther Conductor 200 Sqmm 112 Complete Stay ( Stay Rod 20X1800mm, Stay Wire 7 / 8 Swg 10Kg / Stay, Stay Cla, P, N&B, Washer, 65Wg Earthing Wire With Concrete Grouting ) 113 Earthing Of Pole By Ms Earthing Rod Of 20X2500 Mm & 6Swg Wire Etc 114 Eye Hook Clamp With N & B. 115 Eye Hook ( Insulated ) 116 Suspension Clamp 117 Piercing Clamp 118 Dead End Clamp 119 Top Channel Ms ( 125*65*2240 ) 120 Dropper Ms Channel ( 100*50*2028 ) 121 T Off Channel ( 125*65*1300 ) 122 Cross Arm Ms Angle 65*65*6 Mm V Type 11 Kv 123 Cross Arms Holding Clamps With N&B 124 T / F Base Ms Angle 75*75*6*2028 Mm 125 Holding Clamp With Nut & Bolt 126 11 Kv Fuse Set With Clamp 127 F / E-Bracket For Fitting Top Insulator With N&B 128 11 Kv Tpmo Set 129 33 Kv Line Isolator 130 33 Kv Bus Isolator 131 11 Kv Disc Insulator With Fitting ( T&C Type ) 132 11 Kv Pin Insulator With Pin 133 63 Kva 11 / 0.4 Kv Transformer ( New ) 134 100 Kva 11 / 0.4 Kv Transformer ( New ) 135 250 Kva 11 / 0.4 Kv Transformer ( New ) 136 400 Kva 11 / 0.4 Kv Transformer ( New ) 137 33 Kv Pin Insulator 138 33 Kv Pin With Nut 139 Lt Pvc Cable ( Armoured ) 2*6 Sqmm 140 Meter Box / Encloser Suitable For Various Type Of 1P2w Energy Meter , Plastic Seal And Hologram Seal With Its Dismntalling And Rearrengement Of Installation
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
38.
Public Administrative Department #9361613 Technical Bid
Tender For Rates For Non Csr Item Express Feeder At Municipal Council Ramtek - Outdoor, Zinc oxide gapless type, Lightning Arrestor, 11/9kV, 10/5kA with disconnector Nominal 8/20µs discharge current, 50Hz, energy Class III, Station class , all accessories conforming to IS3070, & IEC:99-4 and as per specifications provided. LA shall mount on febricated structure including construction of suitable hot dip galvanized GI supporting structure, foundation blots & nuts, installation of above equipment, earthing, testing and commissioning (Cost of civil works for foundation will be paid separately). 3 Supply erection testing and commissioning Outdoor,CT 11KV 300/5A 30VA Core-1 CL:0.5, Core-2 CL:5P10, Oil immersed, self cooled, 30VA burden, Frequency 50Hz., all accessories conforming to IEC 44-1-1996 & IS 2705, including control wiring and as per specifications provided, CTshall install on febricated GI structure. including of all materials and construction of suitable hot dip galvanized GI supporting structure, foundation blots & nuts, installation of above equipment, earthing, testing and commissioning (Cost of civil works for foundation will be paid separately). (Gantry structure apx weightalready included in VCB gantry structure) 4 Supply erection testing and commissioning Outdoor, 11/√3kV / 110/√3V, 1-Phase, Two Core Inductive Voltage Transformer, Oil immersed, self cooled, 50VA burden, Core-1 CL:0.5 & Core-2, CL:3P, 50Hz., with all accessories conforming to IEC 186-1987 & IS 3156-1992, including control wiring and as per specifications provided. PT shall install on febricated GI structure. including of all materials and construction of suitable hot dip galvanized GI supporting structure, foundation blots & nuts, installation of above equipment, earthing, testing and commissioning (Cost of civil works for foundation will be paid separately).(Gantry structure apx weight150KG) 5 Supply Installation DISCONNECTING SWITCH/ ISOLATOR (Without Earth Switch) Outdoor, Manual gang operated, 3 pole, Centre rotating Post Disconnecting Switch/ Isolator, horizontal disconnecting double break, 11kV, 400A, 50Hz., WITHOUT Earth Switch, 25kA rated short circuit current, required number of NO + NC auxiliary contacts, including control wiring and as per specifications provided.including all materials and construction of suitable hot dip galvanized GI supporting structure, foundation blots & nuts, installation of above equipment, earthing, testing and commissionin ( 2 nos FOR S/SIncomer VCB + Two no;s for transformer VCB) 6 DISCONNECTING SWITCH/ ISOLATOR (With Earth Switch) Supply erection testing ,Outdoor, Manual & Electrical gang operated, 3 pole, Centre rotating Post Disconnecting Switch/ Isolator, horizontal disconnecting double break, C, 50Hz., WITH Earth Switch, 25kA rated short circuit current, required number of NO + NC auxiliary contacts, including control wiring and as per specifications provided.including all materials and construction of suitable hot dip galvanized GI supporting structure, foundation blots & nuts, installation of above equipment, earthing, testing and commissioning (for 33 KV outgoing feeder) 7 Solid Core Post Insulators for 11KV outdoor application as per IS 731 & 2544, etc. as specifications provided, Supply of all materials and construction of suitable hot dip galvanized GI supporting structure, foundation blots & nuts, installation of above equipment. 8 Design, supply, installation, testing and commissioning of Substation Yard Structureusing hot dip galvanized GI Sections of latticed box type column, gantries, equipment support, plates, pipes, etc. of bolted/welded construction, manufactured out of ISMC / ISA, placed as per design & drawings including GI assembly bolts, nuts, foundation bolts, etc. complete. (Design and calculation shall be got approved before supply & erection). Supply of materials Installation, testing and commissioning (Cost of civil works for foundation will be paid separately).( For one gantry :-Column type HG(4 Nos.)-496.0 kg. Beam type HA(2 Nos.)-261.0 Kg. + other accessories 250 kg) 9 Supply Erection testing and commissioning OUTDOOR 11 KV VACCUM CIRCUIT BREAKER Outdoor Vaccum Circuit Breaker, Suitable for 33/11 KV substation11KV, 400A rated nominal current, 3 Pole, Gang operated, 50Hz., rated for 21kA (3 sec) short circuit current, required NO+NC contacts, control panel, suitable for local and motorized remote operations, all accessories, including control wiring and as per specifications provided. The Ciecuit breaker with pole operatingmechenisam ,Current and potential transformer shall install on supporting structure Circuit breaker shall be structure mounted open type seperate interrupter for each phase mount on single frame , Supply of all materials and construction of suitable hot dip galvanized GI supporting structure, foundation blots & nuts, installation of above equipment, earthing, testing and commissioning (Cost of civil works for foundation will be paid separately). (Gantry structure apx weight 250KG) 10 Supply Erection testing and commissioning ACSR PANTHER conductor of size 30/300mm Aluminium with 7/3.00mm steel wire as per IS398, including connectors, clamps, etc. String the conductors to make busbar, Installation using connectors and clamps, 11 IPS rigid aluminium alloy round tube 50mm for busbars as per IS5082 including connectors, clamps, etc Supply Installation of busbar using connectors, joints and clamps, testing and commissioning. 12 Supply Erection Testing and commissioning Outdoor/indoor CONTROL AND RELAY (C & R) PANELS Feeder and Transformer protection Control and Relay Panel for remote operation and protection of Substation switchyard equipment suitable for 30 V DC. It shall be fabricated out of cold rolled sheet steel of thickness not less than 3mm, powder coated in cubicle compartmentised, free standing, cable bottom entry, floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel, T sections wherever necessary fully meeting all the requirements specified in the technical specifications. Galvanized hardware with zinc passivation shall be used for fabrication. All other requirements of the panel shall be as per specifications provided. It shall consist of Relays /CTs, Multi Function Digital Meters, Mimic diagram, Semaphore indicators, LED Alarm indicating lamps, Annunciation system, Hooter, Communication functions, Internal control wiring, Visual and audible alarm, Interlocking schemes, Remote/ Auto / Manual operation, Test Terminal Blocks, IP4X protection, Earthing, Space heaters, Anti pumping facility, etc Relays in C & R Panel shall be for multi-functional Protection, Control and Monitoring of Feeder lines and Transformers, suitable for remote operation. All types of Protection/Monitoring / Controlling Relays, Auxiliary Relays, Trip Circuit relays, AC Circuit relays, etc. All other requirements of the panel shall be as per specifications provided. Before fabrication of the Panel, electrical and control scheme for the entire substation shall be prepared by the Contractor and hard copies submitted for approval. 13 Rates for NON CSR Item Express Feeder at Municipal Council Ramtek 14 Supply Erection Testing and commissioning Outdoor/indoor CONTROL AND RELAY (C & R) PANELS Feeder and Transformer protection Control and Relay Panel for remote operation and protection of Substation switchyard equipment suitable for 30 V DC. It shall be fabricated out of cold rolled sheet steel of thickness not less than 3mm, powder coated in cubicle compartmentised, free standing, cable bottom entry, floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel, T sections wherever necessary fully meeting all the requirements specified in the technical specifications. Galvanized hardware with zinc passivation shall be used for fabrication. All other requirements of the panel shall be as per specifications provided. It shall consist of Relays /CTs, Multi Function Digital Meters, Mimic diagram, Semaphore indicators, LED Alarm indicating lamps, Annunciation system, Hooter, Communication functions, Internal control wiring, Visual and audible alarm, Interlocking schemes, Remote/ Auto / Manual operation, Test Terminal Blocks, IP4X protection, Earthing, Space heaters, Anti pumping facility, etc Relays in C & R Panel shall be for multi-functional Protection, Control and Monitoring of Feeder lines and Transformers, suitable for remote operation. All types of Protection/Monitoring / Controlling Relays, Auxiliary Relays, Trip Circuit relays, AC Circuit relays, etc. All other requirements of the panel shall be as per specifications provided. Before fabrication of the Panel, electrical and control scheme for the entire substation shall be prepared by the Contractor and hard copies submitted for approval.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
39.
Power #9355489 Technical Bid
Design, Engineering, Manufacture, Survey, Supply, Transportation, Erection, Testing & Commissioning of 1x6.3 MVA, 33/11KV Receiving Station including 33 KV Line at GMC Associate Hospital Rajouri on Turnkey Basis.” under the jurisdiction of Executive Engineer, Sub Transmission Division KALAKOTE, JPDCL Jammu- 1 33 KV LINE BAY OF SINGLE BUS SCHEME (2 Nos); (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 2 SITC OF SUB‐STATION MAIN EQUIPMENT 3 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type)with allied accessories and heavy duty pad clamps. 4 33kV C&R Panel along withO/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port 5 33 kV Isolator With Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 6 33 kV Isolator Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 7 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 8 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ) 9 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 10 33 kV Polymer Post Insulator36kV,170kV Impulse, creepage distance 1224m 11 SITC OF GI STEEL STRUCTURES 12 Nominal Bore 200, 5.9 mm Thick 13 Galvanised Steel Structures 14 Galvanised Nuts & Bolts 15 SITC OF CONTROL CABLES 16 Supply, Laying, Testing & Commissioning of 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 17 Supply, Laying, Testing & Commissioning of 04Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 18 Supply, Laying, Testing & Commissioning of 02 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 19 Lugs, Ferrules etc. 20 SITC OF CONDUCTOR & HARDWARE 21 Providing & Fixing 200 mm² ACSR Conductor Panther 22 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 23 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 24 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 25 GI Earth wire 7/4.00 mm sq. 26 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 27 COST FOR 33 kV TRANSFORMER BAY OF SINGLE BUS SCHEME (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 28 SITC OF SUB‐STATION MAIN EQUIPMENT 29 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) with allied accessories and heavy duty pad clamps. 30 33 kV Isolator with Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 31 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 32 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 33 33 kV C&R Panelalong with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, DLMS Compliant with RS-485 port 34 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m 35 SITC OF GI STEEL STRUCTURES 36 Nominal Bore 200, 5.9 mm Thick 37 Galvanised Steel Structures 38 Galvanised Nuts & Bolts 39 SITC OF CONTROL CABLES 40 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 41 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 42 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 43 Lugs, Ferrules etc. 44 SITC OF CONDUCTOR & HARDWARE 45 Providing & Fixing 200 mm² ACSR Conductor Panther 46 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 47 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 48 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 49 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 50 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 51 SITC of 6.3 MVA 33/11KV Power Transformer; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 52 6.3MVA 33/11kV, ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections and Tertiary Winding. 53 Providing & Fixing of Al Bus bars for transformer terminals of suitable size with color coding, heat shrinkable sleeves covered including drilling, welding etc as per requirement to be fixed on LV side of transformer as per relevant Standards 54 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 55 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 56 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 57 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 58 COST FOR 11 kV INDOOR SWITCHGEAR OF 6.3MVA, 33/11 KV SUBSTATION; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 59 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (1+4)SET 60 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets) 61 11 kV3- Core XLPE 400 mm² armoured, FRLS 62 11 kV3-Core XLPE 120 mm² armoured, FRLS 63 11 kV Indoor Heat Shrinkable Cable Termination Kits 64 11 kV Outdoor Heat Shrinkable Cable Termination Kits 65 11 kV Indoor Heat Shrinkable Cable Termination Kits 66 11 kV Outdoor Heat Shrinkable Cable Termination Kits 67 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. 68 11 Mtr. Long Pole (ST-410 SP56) 69 9 Mtr. Long Pole(ST-410 SP33) 70 33kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 71 33kV HGF Set 3-Phase, 3-Pole, 200 Amp 72 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 73 Galvanisedironof sorts including CH Angle brases Clamps etc. 74 100 KVA, 33/0.04 KV, 3-Phase Distribution Transformer with Bimetallic Terminal connectors Energy Level -2 (Copper wound) (1No. Spare) 75 120 mm²PVCLT Cable 4 Core, armoured, FRLS 76 Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole 77 Earthing of 100 KVA Substation-Excavation of earht pit of dia 650 mm & depth 3000 mm installation of earthing pipe of 40 mm Nominal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239 GI Strip[ for neutral earthing of size 75 mm x 10 mm & 50 mm x6 mm for connection of transformer body, G.O set & lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. 78 Supply ,Installation Testing and Commissioning of Earthing Complete by GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm. 79 11kV Bus Bar Fuse Set Out Door type for Auxilary Transformer 80 COMMON MISCELLENOUS WORKS IN 33/11kV SUBSTATIONS; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 81 Compound wall of Receiving Station By way of mass concreting in foundations and 228mm brick wall of 2 m height including main gate and allied works 82 G.I Chainlink Fencing of 33kv yard by way of mass concreting in foundations and chainlink fencing of 6 ft height using G.I Angle of size 65x65x6mm and G.I Flat iron 50x6mm 83 RCC Cable Duct for laying of 11 KV XLPE Cable from Power transformer to Control Room and Control Room to O/G Structures as per REC Approved Standard Drawing. 84 33/11 kV RCC Power Transformer Foundation (1:2:4) as per REC Approved Standarddrawing foundation complete job for 3.15 MVA Power Transformer 85 33 kV RCC Equipment foundation and Gantry foundationas per REC Approved Standarddrawing (VCB, Isolators, CTs, PIs, LAs etc) complete job 86 Earthing Mat using ( GI Flat 75 x 8mm) and (GI earth rod spikes 2.5 m long 20 mm dia), yard area, as per REC Standerd 87 Earthing Electrode ( 3m long 40mm dia GI pipe) through GI strip (50x6)mm for equipments 88 33 kV Yard concreting and metalling, yard area by providing, supply & laying 100mm thick PCC 1:4:8 using 20mm normal course aggregating and spreading 100mm three layer of 20mm single sized crushed/broken stone, as per REC Standerd 89 Borewell 125mm dia and 100mtr in depth with 2HP Submersible Pump including distribution complete job. 90 BUILDING: A. Control Room Building on ground floorcomplete with Column and Beam structures with 1 no J.E. Room , 1 Store room, 1 Battery Room and a main hall including a luminium windows, cable ducts for power and control cable, Toilet (completewith WC, Washbasin and fittings), electric fittings(fans, LEDtubelights, leds powerpoints and o ther fixtures) 2 coat of putty with Priming coat and Reputed Colour of 2 coats to the entire building as per the direction of concerned engineer , painting of doors and windows etc. Overhead water Storage tanks . Water Supply . Septic Tank complete with Sanitary Fittings including kota stone floor. including RCC slab in furnished conditioncomplete in all respects.(Note: The Contractor shall submit the building drawing in all respects i.e. structural / architectural prepared by authorized Architect for approval from the dept for execution of works.) 91 BUILDING:B. Staff Quarters on 1st floor with Column and Beam structures includingToilets (completewith WC, Washbasin and fittings), electric fittings(fans, LEDtubelights, leds powerpoints and other fixtures of reputed make) Putty of 2 coats , Priming 2 coatsand reputed colour as directed by concerned Engineer to the entire buildingComplete in all respect painting of doors and windows etc. Overhead water Storage tanks . Pantry Room with all the Fittings. Water Supply . including Tile and marble flooring with periphet and Stairs Complete, two room complete with beding chair etc. as per the direction of engineer incharge.(Note: The Contractor shall submit the building drawing in all respects i.e. structral / architechuralprepared by authorised Architect for approval from the dept for execution of works.) 92 Development of land by removing weeds, wild grass and endulation if any, ornamental land scaping and growing of ornamental trees in unbuilt areas/road sides and Construction of approach path by Way of Cement concreteing/ Interlocking tiles/blacktopping including drains complete. 93 SITC of 120 Watts LED Street lights of following watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on 13mtr ST Poles including necessaryboxes/fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.) 94 COMMON MISCELLANEOUS EQUIPMENTS 33/11kV SUBSTATIONS; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 95 a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelenecopolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply . 96 Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Doublebusbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories 97 Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCBs (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories 98 Providing of Bolt cutter of Taparia make BC-42 with allied accessories. 99 Providing of Rubber Mat 1mx2m 19mm thick 100 Providing of Fire ExtingiusherCo₂/ABCType of 4.5 kg capacity for controlroom 101 Providing of 3Sand Bucket Fire Extingiusherwith metallic stand andidentification plates 102 Providing of Industrial safety Helmet 103 Providing of Rubber Gloves for 33 kV level 104 Providing of Rubber Gloves for 11kV level 105 Providing of Industrial Safety Belt with comfort foam reinforment 106 Providing of Safety volcanized rubber Shoes 107 Providing of Telescopic Cabron fibre Earthing rod (set of 3 rods) 108 Providing of HV Detectors all voltages with fibre rod 109 Providing of Chrome vanadium forged Spanners of 10mm to 32mm sizering/u shaped. (set of 10 No.s) 110 Providing of Forged Adjustable wrench of 22mm and 32mm size 111 Providing of Screw drivers setflat cum star bit type dual end (set of 8 no.sof different sizes) 112 Providing of Nose Plier 113 Providing of Normal Plier 114 Providing of Sledge hammer of 2Kg with handle 115 Providing of forged Chisel long shank type 116 Providing of HSS Cabron steel Hack saw with frame and set of 6 blade withtwo sided teeths 117 Providing of Measuring tape of 12 feet spring loaded 118 Providing of Precise 1 feet long bubble based water level 119 Providing of 600 watt hand drill with drill bits of HSS Hammer type 120 Providing of Tool Kit case plastic of Harry-kerry make of 2.5x1x1.5 feetdimensions with different chambers 121 Providing of Clamp meter with multi measuring parametersMarkoni/motwane/fluke make 122 Providing of Screw driver tester neon lamp based 123 Providing and fixing of industrial heavy duty chain block of 1 Ton capacitywith allied accessories complete 124 Providing of Chrome make socket set with ratchet and extension bars of10mm-32mm size sockets with allied accessories 125 Providing of Aluminum industrial ladder split 40 feet extension type withallied accessories 126 Providing of foldable multi-purpose aluminium ladder 127 Office Steel Chairs wih Armrest 128 Office Table of Standard Size with Sufficient Drawers 129 Office Almirah With Locker of reputed make 130 Cost of Installation of Capacitor Bank (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 131 11 KV Capacitor bank 2.4MVAR with VCB Panel with complete arrangement for connection with 11 KV incomer panel, Series Reactor, Isolator, RVT, Surge Arrestor, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with Structure, foundation and accessories. 132 SITC OF 33 KV LINE 133 11 Mtr. Long Pole (ST-410- SP56) 134 GI V cross-arm with top Bracket including clamps 135 GI Channel X-Arm including clamps and braces 136 GI Wire SSS 137 100 mm² AL59 Aluminium Claded Steel Conductor 138 PG Clamps for 100mm² ACSR Conductor 139 Tension Clamps with bail & IPC (Insulation Piercing Conductors) 140 Alignment Ties 141 IPC (Insulation Piercing Conductors) from bare to CC (Covered Conductor) 142 IPC from CC to CC Connection 143 IPC with Aluminium bail for Earthing 144 Mid Span Joint 145 33 kV Isolator without Earthing Blade (36kV, 2500A, Outdoor, 3 poles, 25 kA) 146 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 147 33kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting 148 Galvanized Nuts and Bolts. 149 Danger Plates with Clamps 150 Anti-Climbing Device with Clamps 151 Earthing Complete by GI Pipe 40 mm or GI Rod20mm, 3 mtr long through GI Strip. 152 Red Oxide 153 Aluminium Paint 154 Cement bottoming for 11 Mtr Long ST Pole, 0.78 Cum/Pole 155 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 156 SITC OF 11 kV LINE 157 8 Mtr. Long Pole( ST-410 SP15) 158 GI V cross-arm with top Bracket including clamp 159 GI Channel X-arm including clamps and braces 160 50 mm² ACSR Conductor 161 PG Clamps for 50 mm² ACSR Conductor 162 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 163 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 164 Galvinized Nuts and Bolts 165 Danger Plates with Clamps 166 Anti-Climbing Device with Clamps 167 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 168 Red Oxide 169 Aluminium Paint 170 Cement bottoming 1:2:4 mix as per REC standards .45cum /pole 171 Aluminium Jointing Sleeves 172 Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
40.
Defence #9353987 Technical Bid
Tender For Provision Of Work Services For Solar Power Plant At Af Stn Adampur; 1 SCHEDULE `A PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. 2 Construction of SUB STATION BLDGcomplete all as specified and shown on drawings. 3 NOTE: Schedule ‘A’ Part IIto X under Ser No. 2.01to 2.10 are Prepriced by MES. 4 Lump sum price worked out by the Contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’Part II 5 Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION as listed in Schedule ‘A’Part III 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY as listed in Schedule ‘A’Part IV 7 Lump sum price worked out by the Contractor for “SOLAR POWER PLANT” as listed in Schedule ‘A’Part V 8 Lump sum price worked out by the Contractor for “ROAD/PATH/CULVERT” as listed in Schedule ‘A’Part VI 9 Lump sum price worked out by the Contractor for“EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’Part VII 10 Lump sum price worked out by the Contractor for“EXTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’Part VIII 11 Lump sum price worked out by the Contractor for“SEWAGE DISPOSAL ” as listed in Schedule ‘A’PartI IX 12 Lump sum price worked out by the Contractor for“AREA DRAINAGE” as listed in Schedule ‘A’Part X 13 Lump sum price worked out by the Contractor for“FENCING AND GATE” as listed in Schedule ‘A’Part XI 14 SCHEDULE `A PART - XII MISC ITEMSis not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. 15 INTERNAL ELECTRIFICATION 16 S&F LED light fitting 1 x 10 Watt, 220V, AC,box type with driver, holder incl making connection with three core flexible copper conductor cable 0.5 sqmm from ceiling rose complete all as specified and directed. 17 S&F LED security light fitting 20 watt, input 110 to 220 voltsas per IP 65 luminaries comprising of rectangular shape, high pressure die cast aluminium housing, with weather proof gaskets for lamp and driver compartment with GI pipe 25 mm dia light grade bend to shape including necessary fixing arrangement complete all as specified and directed. 18 SOLAR POWER PLANT 19 Design, supply, erecting, installation, testing & commisssioning of ON Grid connected, ground mounted solar PV Plant of 737 KWp capacity at standard condition (irradience temp etc) at AF Stn Adampur (Longitude 75° 44 20 E, Lattitude 31° 26 14 N & elevation 244.54 mtr). The ripple content shall not exceed 3% on DC and harmonics shall not be more than 3%, Micro processor based directional & revese power flow protection shall be provided to ensure isolation of SPV from Grid at the time of fault including all connected equipments required for their smooth functioning comprising of the following major componenets all as specified:- 20 Supply, erecting, installation, testing & commissioning of framed dual glass bifacial Solar modules each consist of 144 cells (12x6+12x6), size of module 2278mm (L) x 1134mm (W) x 33mm (T) or as approved, M10 TOPCon N type mono bifacial solar cells not less than 585 Wpeach, front glass 2mm low iron printed semi tempered glass, back glass 2mm low iron printed semi tempered glass, PID free & UV resistant encapsulate, IP68 weatherproof PPO junction box, compatible with IP68 rated MC4 connector alogwith 1400mm DC, Copper cable of 4sqmm size, anodized aluminium framehaving efficieny more than 22.5% at standard test condition. These panels shall be suitably fixed on Module mounting structure. The electrical Data of panel at standard test condition (STC) 1000W/m² irradiance, air mass 1.5 & 25°C cell temperature shall be as under:-(i) DC peak power (Pmax) - not less than 585 Wp. (ii) DC peak voltage (Vmp) - 44.15V (Approximate). (iii) DC peak current (Imp) - 13.25A (Approximate), (iv) Short circuit Current - 13.99A (Approximate). (v) Open circuit Voltage - 52.70V (Approximate). (vi) Module efficiency - 22.65% (Approximate). (vii) Operating temp range (-) 40°C to 85°C. (viii) Series fuse rating = 30A (Approximate). (ix) Junction box = IP68, weatherproof PPO. (x) IP68 rated MC4 connector compatiable. (xi) Anodised aluminium frame. (xii) front glass 2mm low iron printed semi tempered glass. (xiii) back glass 2mm low iron printed semi tempered glass, PID free & UV resistant encapsulate. (xiv) Sustain heavy snow upto 5400 Pa. (xv) Sustain wind loads upto 2400 Pa. 21 Note :-(a) The PV modules must be tested and approved by one of the IEC authorised test centers. In addn a PV module qualifacation test certificate as per IEC standard, issued by ETDC Bangalore or Solar Energy Centre will also be valid. (b) Warranty on output and life of structure shall be as under :-(i) Output wattage of PV modules shall not be less than 90% at the end of 10 years and 80% at the end of 25 years.(ii) The mechanical structure, electrical works and overall workmanship of the grid solar power plant must be warranted for a minimum of 5 years.(iii) Grid solar PV power plant must install necessary equipment to measure solar radiation, ambient temperature, solar energy meter 11 KV to measure grid solar power generation, wind speed and other weather parameters contnuously. Simullataneuosly measurement of the generation of DC power as well as AC power from the plant must be done. 22 (c) Each module shall have RFID tag bearing the following details. RFID reader shall be provided by contractor :-(i) Name of manufacturer of PV module (Should be made in INDIA). (ii) Name of manufacturer of solar cell (Should be made in INDIA). (iii) Month and year of manufacture (Separately for cell & module). (iv) Country of origin separetly for cell & module (Made in INDIA only). (v) Peak Wattage, Im, Vm and fill factor of the module. (vi) Date of year of obtaining IEC PV module, qualification, certificate. (vii) Unique serial no and model no. of Module. (viii) I-V curve of module. (ix) Name of the test Lab issuing IEC certificate. (x) Every module should have PID test report as per latest prevalling norms of MNRE & will be submitted to the GE. (xi) Solar cells & Modules shall meet DCR norms. 23 (d) Provision of earthing and earth strip/cables etc. for earth for solar PV module/Array as per latest IS/MNRE norms to be providied it will be measured and paid seperatly. (e) PV module shall confirm to IEC:61215, IEC: 61730, UL:61730-1 & 2 for construction, testing and safety qualifacation and latest minimum technical specifications. The module shall be manufactured in 2024 or subsquent year. Product warranty shall be for at least 12 years and performance warranty shall be at least 25 years. 24 (f) The contractor will submit the complete design of ON Grid connected Solar PV Plant alongwith complete design details, drawings, calculation sheet and connected documents within one month of acceptance of tender and before procurement of the material. The same shall be submitted to GE after vetting from IITs/NISE for approval of accepting officer. (i) The complete design will submitted to Accepting Officer through CWE for final approval before placing order of the materials to be used in Solar PV Plant. (ii) The test report of modules as per national and international standards and technical data shall be submitted by contractor to GE for approval of accepting officer. (iii) Minimum 0.5% of PV Module shall be tested for all electrical parameters incl efficieny & safety measure by the rep of AO at OEM factory premises before dispatch as per technical data sheet of the manufacturer. (iv) Contractor will submit 2% amount of total quoted amount against item Sl No 4.04 (PV Module) as performance security of PV Module in the form of FDR or BGR in favour of the Accepting Officer which will be refurned to the contractor on successful performance copletion of 25 years of PV Module.(v) Contractor will submit gurantee for at least 25 years performance of PV Module as per CA provision and in case of any manufacturing fault of any PV Module during the performance warranty of 25 years the same shall be replaced by the contractor without any extra cost. (vi) All the modules shall be of same make. (vii) Rates of testing at Factory premises of OEM or MNRE approved Lab are deemed to be included in the quoted rates.(g) Make : MNRE approved and as per list of makes mentioned in Appx D of the tender documents. 25 (viii) The solar power plant shall be got tested/ inspected by third party i.e. NISE or any other Govt approved lab as decided by Accepting officer. Cost of testing and all other arrangement for this shall be made by the contractor without any extra cost.Third party inspection/ testing shall be carried out after execution of complete work and all departmental testing. (ix) Acceptance/ Final test from rep of Accepting Officer shall be carried out after physical completion of solar power plant work.All arragement for this shall be made by the contractor without any extra cost. (x) The following tests shall be carried out: (i) Performance ratio test (ii) CUF (iii) Efficiency test (iv) Irradiance test (xi) All drawings and design duly supported with detail calculation and property of the equipment shall be submitted by the contractor within two months from the date of issue of work order for approval of the Accepting officer. 26 Design, supply, installation, testing & commissioning String PV Inverter of capacity not less than 250 KW. Input DC & output AC specification of the inverter shall be as under :-Input DC. Max input DC voltage not less than-1500V, rated input voltage not less than 1080V, start up voltage 550V, minimum MPPT voltage range 180-1500V DC, MPPT voltage range at full load 800-1300V DC, minimum number of string input 24, minimum number of MPP trackers-12, string per MPPT- 2 Nos, max input current per MPPT shall not be less than 30A, max short circuit current per MPPT shall not be less than 50A. 27 Output AC.Minimum AC output power 250 KVA@30°C, 235KVA @40°C, 220 KVA @ 50°C, max output current not less than 184A, Nominal 3 phase voltage- 800V, minimum Grid voltage range 640-920V, Frequency- 50/60Hz, Grid frequency range - 45~55Hz, Active power adjustment range- 0-100%, THDi- <3%, power factor 0.8 leading-0.8 lagging, 3 phase.Performance.Max efficiency - not less than 99.01%, European weighted efficiency - not less than 98.8%, outdoor string solar power grid tie inverter suitable to convert DC power of solar PV module/array to AC for further feeding to grid & conforming to IEC-61683 for efficiency, IEC-62109 (1&2) or equivalent for safety & IEC-62093 for reliabilty. The inverter shall be self-communicated with pulse width modulation (PWM) technology and shall be capable to synchronize with grid maximum in 1 minute. Maximum Power point tracker (MPPT) conforming to IEC-62093 shall be intergrated in the inverter to maximize energy drawn from the solar PV array. 28 The inverter shall have following protections:- (i) DC reverse polarity protection. (ii) Anti Islanding protection. (iii) Leakage current protection. (iv) Ground fault monitoring. (v) PV array string fault monitoring. (vi) Zero voltage ride through. (vii) DC switch. (viii) Anti PID protection. (ix) AFCI protection (Arc Fault Circuit Interrupter). (x) Over voltage. (xi) Under voltage. (xii) Overload. (xiii) Shorcircuit. (xiv) Earth fault. (xv) Under frequency and over frequency.Protection class/Overvoltage category- I/III. Input/output SPD- PV type-II & AC type-II standard. Electromagnetic compatibility (EMC) as per EN-61000-6-2&4. Safety standard as per IEC62109-1/2, IEC62116, IEC61727, IEC61683, IEC60068(1,214,30). Communication- RS485, USB, Bluetooth, Wi-fi, GPRS, PLC.Inverter shall monitor the following:-(i) DC input voltage (ii) DC input current (iii) DC ripple (iv) DC input power (v) AC output (vi) AC output current (vii) AC output power (viii) AC output frequency (ix) AC output power factor (x) Synchronization status (xi) Grid voltage (xii) Grid frequency (xiii) Grid (ii) Ground fault (iii) PV string fault montioning inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. 29 General specification:- (i) Ambient temperature range - (-) 30°C to (+) 60°C. (ii) Self consumtion power at night - < 2W, Topology- Transformerless. (iii) Degree of protection - IP66. (iv) Allowable relative humidity 0-100%, max operating altitude - not less than 4000M, (v) Noise - <60Db. (vi)Cooling - Smart forced air cooling. (vii) Display - LCD & Bluetooth+App.Rate for PCC foundation including required concreting and steel fixing as instruction and directed by engineer-in-charge are deemed to be included in quoted rates.Isolation method tranformer less smart forced cooling LED display, Rs 485/PLC communication, smart IV Curve Diagnosis, Type II SPD for both DC & AC with 5 years guarantee. Make: HITACHI/Delta/Sungrow.Note:- (i) Contractor shall submit parameter sheet of inverter duly recommended by GE & CWE for approval of AO before placing order to the company. (ii) All the inverter shall be of the same make & model. 30 MC4 CONNECTORSSupply, installation, testing & commissioning of solar MC4 connectors (Male and female both) having copper pin with tin plating with 1500 V DC & not less than 30 Amp. Current suitable for 4/6 sqmm cable, degree of protection IP-68, contact resistance < 2 mili ohm, insulation resistance >500 Mega ohm, insulation material PPO, protection class-II, application class A, standard EN 50521: 2008 TUV certified and shall also meet the requirement of IEC:61984 complete all as specified and directed. Make: Indygreen/Elmax/synergy/Eteilyte Technologies India Pvt Ltd . 31 Modules Mounting Structure (MMS) Design, supply and erect Module mounting structure made up of MS Hot dip Galvanised (80 Micron) as per IS 4759, GI frame Structure to hold approved solar panels mounting with all accessories.Fixing arrangements for fixing the PV solar modules & to withstand minimum horizontal wind speed of 170 km/ hr as per IS. It shall conforming to latest revesion of IS 2062 having Grade of 250 MPA. The MMS design shall be submitted by the contractor and shall be approved by AO. The solar panel shall be fixed at a tilt angle of 31° or as per designed SPV Plant. Note : The design should be similar as per drawing attached. 32 Mounting Structure shall have following specification:-(i) Nut, bolts and supporting structure including module mouting structure shall have to be adequately protected from atmosphere and weather prevalling in the Adampur Air Force Station. All fastners shall be of stainless steel of Grade SS 304.(ii) Two numbers of anti-theft fastners of stainless steel on two diagonally opposite comer of each module shall be provided.(iii) The rep of AO, shall visit the factory site of galvanising for each section of lot of dispatch to collect the samples at random & send the sample duly sealed & signed by him and rep of contractor to nearest NABL accredited Lab for testing. The lot will bedispatched from factory permises only after passing of sample from Lab. In case of failure of sample complete lot will be rejected. The quoted rates are deemed to include these provisions. 33 Note:- (i) cost of interconnecting copper cables along with cable trays (floors/ wall mounted) suitable to accommodate solar grade cables & cables upto invertersshall be measured and paid separately under relevant items. (ii) Earth work and foundation of MMS shall be measured and paid separately under relavent items (iii) MM structure shall be paid as per actual size installed st site. 34 M&L for tinned copper conductor, 6 Sqmm XLPO insulated and sheathed, UV-stabilized, single core multi-stranded DC cables- RED & BLACK (FOR PANEL INTER CONNECTION), complete as all specified below and directed.(1) Construction(i) tinned copper conductor IEC 60228, class-S(ii) Insulation/sheath:- electon beam cross linked halogen free & flame retardant compound (XLPO)(2) Electrical(i) Voltage Test: 6500V as per EN 50395 (ii) Max permissible operating Volatge:- DC 1.5 KV (conductor-conductor, non earthed system)(iii) Nominal Voltage :- AC 0.6/1.1 KV & DC -900/1.5 KV(3) Temperature(i) Amblent temp: (-) 40°C to (+) 90°C (ii) Max conductor temp (-) 40°C to (+) 120°C(4) Strandards & Material properties(i) Fire performance -IEC 60332-1-2(ii) Smoke emission:- IEC 610374/EN 50268-2(iii) Approval :- EN 50618, HIZ272-KMake: Polycab/Havells/Finolex/KEI India/RR KabelNote: (i) Routine testing of cable shall be carried out by rep of AO at the factory premises of OEM, before dispatch. 35 Supply and laying in trenches, 3.3 KV underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 3300 Volts grade, cross sectional area 300 Sqmm, 3.0 core multistranded, confirming to IS-7098 (Part-1):1988 suitable for earthed system including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-Charge. (ACDB to LT Panel and LT Panel totransformer). 36 All same as per item No 4.17 above but size of 120 Sqmm 3.0 core (Busbar No 1 to ACDB No 1, Busbar No 2 to ACDB No 2 and Busbar No 3 to ACDB No 3) 37 M&L for 70 Sqmm 3.0 core, 1100 volts grade PVC Copper Cable flexible, conforming to IS 7098 (Part-2):1988 (Inverter No 1 to Busbar No 1, Inverter No 2 to Busbar No 2 and Inverter No 3 to Busbar No 3) complete all as specified and directed by Engr-in-Charge. 38 HT TRANSFORMER (INVERTER DUTY FOR SPV PLANT)Supply, installation, testing & commissioning of copper wound, step up cum inverter duty conforming to IS:2026 or latest IS standard, HT Transformer, outdoor type capacity not less than 1000 KVA, 0.800/11KV, 50 Hz, Dyn 11, ONAN class A for solar application, Star Delta Tapping + 7.5 % to -7.5% @ the step of 2.5% ON load type tap changer, with first filling of transformer oil as per IS:355, ISI marked , duly filtered & Dehydrated and other standard fitting/ accessories including Platform & foundation for Transformer installation as recommended by manufacturer. The total losses (No load + Full load) at 75 deg C shall not be more than 1% of rated capacity of transformer, Impendence 5%. The following are included:-(i) Name, rating & diagram plate. (ii) Tap changing switch. (iii) Earthng terminals. (iv) Lifting lugs. (v) Oil level indicator 150 mm dia with alarm & trip contact. (vi) Oil drain valve with plug (vii) Oil filter valve with plug. (viii) Conservator with oil filling hole with cap. 39 (ix) Thermometer pocket. (x) 4 Dial type thermometer stem type & with MRP. (xi) Air release plug. (xii) Silicagel breather. (xiii) Removable inspection opening on top cover. (xiv) Explosion vent. (xv) Bi-directional CI rollers. (xvi) Arching horn set. (xvii) Winding temperature indicator with alarm & trip contact. (iii) Marshalling box for 03 Nos. (iv) Magnetic oil level gaugue (v) Pressure release valve (PRV) with trip contact. (xviii) Conservator with oil filling hole with cap & drain plug and with bulit in diaphragm to avoid direct air contact with transformer oil. (xix) Oil level indicator with minimum level marking. (xx) HV cable box (xiv) LV cable box (xv) Bucholz relay with control connection upto HT VCB including testing at OEM premises.Note : Cost of PCC foundation as per OEM foundation drawing & necessary earth work (excavation, returning filling & making good to surface) shall be deemed to be included in quoted rate.Make:- GEC (Prolec)/ABB/Siemens/Schneider/ITE Gurgaon/CG Power & solution Ltd. 40 M&L for 50 Sqmm single core, 0.6/1.1 KV PVC insulated and PVC sheathed Copper flexible cable, IS :7098 complete as all specified and direcetd. (LA Top to Earth strip of pit) 41 M&L for 6 sq.mm single core, PVC insulated and PVC sheathed copper flexible cable, IS :7098 complete as all specified and direcetd. (LA Top to Earth strip of pit) 42 M&L for 1 sq.mm , 2 core, RS 485 cable twisted shielded unarmoured copper cable complete as all specified and directed (Data Monitoring Cable for communication) 43 ACDB Panel for 750 KWp Inverters (3x250 KW inverters) Design, supply, installation, testing & commissioning of outdoor type, floor mounted ACDB Panel for 750 KW Inverters having 3 incoming & 1 outgoing, IP-65 protection rating with PCC foundation for civil works (Excavation, cutting, Grouting, PCC etc) Fabrication with 3.15 mm thick CRCA sheet steel, 7 tank power coated, floor mounted panel with 40x40x6mmMS angle stand, cable entry from bottom through gland plates, internal control wiring with suitable size copper cables, cable alley, three numbers 1200 Amps aluminium bus bar EC grade incld heat shrinkable PVC sleeves complete all as specified and directed and having following switchgears :- 44 OUTGOING:-1 No.800 Amp, 3 Pole,50Hz, 3 phase, ACB Drawout type, motorised charging, with microprocessor release, Icu = Ics = Icw 50 KA,suitable for 800 volt, 3 phase, 50 Hz with ACB spreader Link with R,Y,B LED indicating light, digital Multimeter 800 volts CL-1, 3 Nos Metering CT 800/5A TP SPD Type 1+2 40 KA. INCOMING :-3 x 250 Amp, Icu = Ics = 36 KA 3 pole MCCB microprocessr released with spreader links. The panel should contains follwoing metering devices :(a) Volt meter with selecter switch -01(b) Ammeter with selecter switch -01(c) Frequency meter - 01(d) R,Y, BIndication Lamp LED type- 01 Set of three.(e) PT 800V/110V,-01 Set of three.(f) CT 800A/5A, CL-0.2, 5VA- Set of three(g) Auxiliary transformer 50 VA, 800V/230V - 01 NoNote:- Contractor shall submit drg of ACDB panel to GE for approval of accepting officer before procurement. 45 LT Panel for 750 KWp inverters Design, supply, installation, testing & commisssioning of outdoor type, floor mounted LT panel of 3.15mm thcik CRCA sheet steel powder coated for 750 KWp inverters having 1-input & 1- output, IP-65 rating, cable alley with PCC foundation for civil works (excavation, cutting, grouting, PCC etc) TP SPD,type 1+2 40 KA, MCCB extended ROHM, all cable entry from bottom through gland plates, 3 Nos control fuse 16A with base for SPD,three 1200 Amps Aluminium bus bars Ec grade incl heat, shrinkable PVC sleeves, Aluminium busbar links, internal wiring with suitable size copper cables, with 40x40x6mm MS angle stand , 7 tank powder coated, three 6A SP 10KA MCB C Curve etc complete all as shown on drawingscomplete all as specified and directed. 46 INCOMING:-1 No of 800 Amp 3 pole ACB, Icu = Ics = Icw = 50 KA- 800 Volts, drawout type, motorised charging, with microprocessor release ACB/MCCB Spreader links.OUTGOING1 No of 800 Amp 3 pole ACB, Icu = Ics = Icw = 50 KA- 800 Volts, drawout type, motorised charging, with microprocessor release ACB/MCCB Spreader links:- The panel should contains follwoing metering devices :(a) Volt meter with selecter switch -01 No(b) Ammeter with selecter switch -01 No(c) Frequency meter - 01 No(d) R,Y, B Indication Lamp LED type- 01 Set of three.(e) PT 800V/110V,-01 Set of three (f) CT 800/5A, CL -0.2 , 5VA - Set of three(g) Auxiliary transformer 50 VA, 800V/230V -01 No.Note:- Contractor shall submit drg of Panel to GE for approval of accepting officer before procurement. 47 COPPER BUSBAR CHAMBERM&L for outdoor type, floor mounted , vermin proof, totally enclosed bus bar chamber of not less than size 800 mm (H) x 800mm (W) x 600 (D) made out of 3.15 mm thick CRCA sheet , incl three number 300 Amps pure copper busbar having size of 200 MM (w) x 100 MM (thick), 0.5 Mtr length/ phase incld heat shrinkable PVC sleeves, duly supported on insulators, it shall be IP-65 rated. Cable entry from bottom and suitable for input of 70 sqmm, 1.1 KV copper cable and output of 120 sqmm, 1.1 KV XLPE cable, powder coated complete all cable entry from bottom through gland plates all as spceified and directed. 48 MONITORING SYSTEMDesign, Supply, installation, testing & commissioning of monitoring system to monitor the performance of the PV Module & inverter (Power arrray voltage, array current & AC parameters), energy yield temperature, irradiance level, humidity, Air Mass, wind velocity etc, and it could provide flexible interface to facilities PC based inverter monitioing and control via GPRS modem and internet/ethenet connection. This should have include web visulization system and data logger with integrated ethernet port. The monitoring system shall be comprises of following :-(a) 5G based plug and play RTU with smart data logger to connect inverters & sensors - 1 Set. (i) Modbus RS485 RTU. (ii) 2 Analog ports. (iii) Built in memory help store and send data in case of network failure. 49 (b) IP-67 Enclosure box (280mmx190mmx130mm) or as approved with SMPS power supply and other accessories to house the RTU - 01 No.(c) Access to web portal-server charges for 1 years data frequency 10 minutes.(i) Interractive Dashboard. (ii) Single line diagram. (iii) PR analysis. (iv) Solar radiation & weather data. (v) Graphics and reports. (vi) Generation analysis. (vii) Log reporting. (viii) String/MPPT monitoring. (ix) Plant/Inverter performance. (x) Superuser dashboard for centralized monitoring. (xi) Mobile app on android. (d) Weather sensors.(i) Solar radiation sensor with mounting kit - 01 No. (ii) Wind speed sensor with mounting kit - 01 No. (iii) Ambient temperature sensor with mounting kit - 01 No. (iv) Module temperature sensor with mounting kit - 01 No to be provided complete with readouts integrated with the data logging system. 50 (v) Analog to modbus module - 01 No. (vi) Wind direction sensor with mounting kit - 01 No.(e)All in one Desktop computer, 12 th Gen intel core i3, 21.5 inch monitor screen, FHD display, 8 GB RAM, 512 GB SSD with Window 11 including wireless keyboard and mouse complete. Make : HP / Dell/ Lenovo / Microsoft(f)Laser Jet Printer, print speed not less than 18 ppm, power consumption not more than 320 watt, capable to print on A4, A5, B5 & legal size paper, single function including power cable & USBcable, toner, installation CD and user manual complete. Make : HP / Canon/ Xerox 51 Note : The following information shall be displayed in the monitoring system:-(i) Individual module power generation, voltage, current, irradiance and temperature etc.(ii) Individual string power generation, voltage, current, irradiance and temperature etc.(iii) Total power generated of all strings, voltage, current, irradiance and temperature feeding to each invertor. (iv) input voltage, input current, output voltage, output current and power losses of each inverter.(v) Total power, voltage, current, temperature at input of solar transformer, also output parameters such as output voltage and output current of solar transformer. 52 EARLY STREAMER EMISSION (ESE)Supply, installation, testing & commissioning of 5m high, advance active on generating Early Streaner Emission (ESE) lightning arrestors with lightning counter to provide radius of protector of minimum 107 m at level-IV. The lightning arrestors shall conform to IEC 60099-4 or IS 3070 except to the extent modified in the specification. Arrestor shall be hemetically sealed units, self -supporting construction, suitable for mounting on lattice type support structurs complete as specified and directed by the EIC & shown in drawings. 53 Lightning Protection system on protective Early Streamer Emission (ESE) technology confirming by NFC 17-102-2011 and UNE 21186 Standard, Non electronics based deivce shall emit electronmagnetic impulse in the form of a streamer intothe air microseconds earilier than naturally.(i) Lightning impulse current (10/350 µs) in 100 KA tested (ii) Serial no mentioned in Each Model of Air Terminal quality certificate. (iii) Material metal housing stainless steel 304. (iv) central rod dia 20 mm elect/magnetic shielding (v) can be qualified in compliance of CPRI (central power research institute). Govt of India for the Impluse current of (8/20 µs) in 40 KA with 5 poistive & 5 negative impluse (vi) Covering radius 107 meter in Level-IV Protection with 8 mtr mast. 54 Lightning Air Terminal Adaptor. Supply of highly insulated polyplatic adaptor to fix the lighnting ESE air terminal with the mat. The adaptor shall have suitable metal connector/ connecting point in such a way the top portion shall be electrically connected to the central final trip (elevated sharp tip) of the ESE air terminal and the bottom portion shall be connected to the down conductor. 55 MAST GI (supporting mast): supply of GI mast for mounting the terminal & adaptor with the ESE air terminal i compliance with IEC 62561-1.(i) GI mast length:- 8 Mtr (ii) GI pipe heavy duty, bottom 80mm dia, 3m, middle pipe dia 65mm, 2m (iii) standard: IS 1239 Part I): 2004 (iv) Base plate: GI Base plate size (250x250x5mm) (v) both the GI mast to be connected with the help of 2 flanges with 4 GI plated nut bolt with washers. The base plate size in (300x300x6mm) GI with requisite fitted with 4 hold the mast. (v) Necessary concrete foundation, earth work for holding the lightning conductor in position is deemed to be included in quoted unit rate. 56 Guy Wire Kit: Supply of Guy wire GI Nickel coated 4mm dia. Covered with white sleeve for extra protection and avoiding rusting. Length of the Guy wire is 6 mtr x 3 no = 18 mtr with accessories like:(i) Guy wire Nickel coated with white convered waterproof sleeve-18 metre(ii) U clips - 6 nos (iii) Pin type zebra anchor fastner-4 nos (iv) O hook- type fastner/ eye bolt fastener-3 nos (v) GI nut bolt 12mm dia of suitable lenth - Nos as per site requirement. 57 Lightning Strike Counter: minimum sensitivity of 250 A at 100 KA.(i) Display Model: digital display (non- resettable type) (ii) Display Range: 000000 to 999999 (iii) Detected Maximum discharge current : 350 A, 10/350 microsecond wave (measurd according to NFC standards per IEC 60060-2)(iv) Tested as per IEC-60060-2 (v) Degree of protection : IP 65 (vii) Operating Temperature (*C): 20+~85 (viii) Strike count display 6 digt (ix) Standard NFC17 102 (2011) Make- Saboo Sysyems Pvt Ltd/KMV/ABB/Axis India Note: Item No 4.34 to 4.39 (i) Lightning arrrestor & its components shall preferably be supplied by same manufacturer. The installation shall be carried out by rep of manufacturer. Testing of LA shall be done in presence of Engineer- in- charge. 58 Chemical Gel Earthing system: Supply for advance chemical Gel earthing system of 1 No. of UL certified 7 CPRI tested environment friendly ground enhancing compund. The copper bonded rod shall be 3 mtr long, 17.2mm diameter 254 microns copper bonded steel rod surrounded with 25 Kg each or more quantity of resistance lowering grounding minerals ROHS certified. Distance between the rod shall be length of the rod all as shown on drawings.(i) Tested as per IEC 62561-2 (ii) CPRI tested at 5 positive & 5 Negative impluse 25 KA (iii) Meets the requirments as per IS 3043, IEC 60964-5-54, UL 467 (iv) Standard- As per IS-3043 & IEEE80-2000, Test certificate from NABL lab. Make : Pragati Electrocorp (P) Ltd Gurgaon / DEHN / JEF Techno 59 Pit Chamber-Round value box supply of FRP heavy duty UV resistance, weather proof earth pit cover as per OEM recommendations complete all as specified and diected. 60 M&L for UPVC pipes of 40 mm size for DC wires, having pressure capacity of 10 kg including fiting viz joints bends, tees, etc complete all as specified and directed. 61 M&L for UPVC pipes of 25mm size for DC wires, having pressure capacity of 10 kg including fiiting viz, joints, bends, tees etc complete all as specified and directed . Note:-(i) Earth work shall be measured and paid under relevant item. 62 M&L for perforated hot dipped galvanized iron cable tray having cable tray for AC & DC cable routine (300 x 50 x 5mm and 450 x 50 x 5mm) thickness 1.5 mm galvanization and perforation not more than 17.5% includeding fittings viz joints, bends, tees, etc in convenient section of length complete all as specified and directed. 63 Supply, installation, testing and commissioning of Vacuum Circuit Breaker 630 Amps, having rupturing capacity 350 MVA, HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad constructed from Aluminium Zinc sheet steel of 2mm thickness for incomer as ICOG confirming to IEC-62271-200 complete with, overload and earth fault protection, ammeter, voltmeter complete as incomer circuit breaker all as specified and directed alongwith following technical specifications:-(i) 630 Amps rating. (ii) Horizontolly draw out type. (iii) Trip rod and have RoF type & Rack in Rack out motorised type. (iv) Motorised spring charging mechanism with integral spring charging handle for manual spring charge. (v) Panel separation with every department like VCB, Metering, cable chamber & Bus bar chamber. (vi) Cast resin current transformer 11 KV, 600-300/1+1A, core 1, class 0.5, 15VA wih metering and protection core including necessary control wiring & PT 11 KV, core-I class, 3 Pole, Core-II class-0.5, 50 VA burden OVF 1.9 for 30 Second for metering & protection backed by HT & LT MCBs. (vii) Line PT should be mounted on rear side (top or bottom) of the panel. 64 (viii) Accessories like local remote switch, breaker control through MCB, indicating lamp RYB, spring charging, DC supply healthy, breaker ON/OFF breaker in service/test, multi function meter with RS-485 port (EM-6400NG), Digital Ammeter and Volt Meter, (ix) Separate master trip relay and anti pumping relay. (x) Comprehensive numerical protection relay should have built in integrated mimic compatible IEC-61850 for non-directional O/C, E/F,U/V, O/V protection type having following additional facility:-(a) Trip circuit supervision. (b) Distribution recorder. (c) Event log with date and time. (d) Conformal coating for harsh environment. (e) suitable to operate on 24 Volt DC for auxillary and control supply. (f) Fully internal arc type (25 KA for 1 second) as per latest IEC:62271-200. (g) Vacuum bottles should be tested for 100 full short circuit operations. (h) Manual closing/tripping of CB with compartment door closed. (j) The panel shall be provided with power pack battery backup for not less than 10 minutes. 65 (k) The height of the HT section should atleast be of 1400mm for human safety during the internal arc creation. (l) Breaker shall be provided with 6NO+1NC contacts for each position in service and test, (m) Wireless thermal sensor will be provided in each bus & each cable termination per panel, alongwith Zig-b contactor and the data of the same should be display on HMI. (n) The VCB shall be SCADA compatible. (o) The VCB interrupter, breaker & panel alongwith relay should be of same make for better coordination and better SCADA compatibility. 66 Supply, installation, testing and commissioning of three phase, 4 wire Bi-Directional HT CT/PT Digital Energy Meter automatic grade as per relevent IS, 110-240 V, (66 KV/Ѵ3/110/Ѵ3) industrial application, Optical Port, RS 232/485 communication current rating Imax 2A -/1A, automation grade, accuracy class 0.2s, D3M024 type and suitable to install between 66 KV Sub Station (Commercial supply of PSPCL) in replacement of existing PSPCL energy meter and 750 KWp Solar power plant, display parameters like KWh, KVArh, KVAh, KW, kVA, Frequency, Power Factor, Current, import and export of energey complete all as specified and directed by Engr-in-Charge. Make : Secure, model : Premier 300 or its technno commercial equivalent.Note : The contractor shall liaise with PSPCL for testing & calibration of the meter. Cost of the same deemed to be incuded in quoted rates. 67 ROAD/PATH/CULVERT 68 M&L for providing and marking broken centre/ side lines/zebra Lines, dashes, arrows etc on road pavement and the like of any description and width with thermoplastic paint hot applied with machine confirming to BS-3265 and according to the specification laid down by IRC and MOST (Mininstry of Surface Transpost) specification 2001 (4th revision) complete all as specified and directed. 69 EXTERNAL WATER SUPPLY 70 Construction of brick masonary valve pit of size 1000x1000x1000mm (internal dimension) with and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm x 5 mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer on MS cover and frame including necessary excavation and earth work in any type of soil, returning, filling in approved soil, disposal of surplus soil to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, brick work using pulverised fuel ash lime bricks in cement mortar 1:6, 15 mm plastering in cement mortar 1:4 both internally and externally, 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified and directed by Engr-in-Charge. 71 PVC HDPE rotational moulded 5000ltr capacity water storage tanks (Cylindrical vertical type with closed top) triple layered,fixed in position and making inlet and outlet water piping line connections complete all as specified. Note : Staging for PVC water tank shall be paid separately under respective item. 72 S&F Pumping sets, centrifugal monoblock, electric driven, single phase, 2HPhaving discharge capacity 3.2 LPS at 20 mtr head, suction x delivery size 50x40mm all as specified and directed by EIC. 73 Supply and fixing PVC air braided hose pipe 25mm dia. 74 M&L for provisioning of staging at 2 mtr height for PVC HDPE storage tank 5000ltr capacity. Note : S&F of PVC water tank of 5000 ltr capacity not included in this rate and shall be paid saparetly under respective item. 75 SEWAGE DISPOSAL WORKS 76 Supply and fixing ofLLDPE septic tank designed to carry sewage and sullage, water including excavation in anytype of soil, PCC 1:4:8, PVC Pipe from last manhole to septic tank, vent shaft, vent cowl and misc connection like PVC Tee, PVC bend etc. complete for PWTS-STBF-160-01 (1600 Lts Capacity) (Make - Sintex) 77 Soakage wells exc, in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/ RR masonry / Filling with brick bats, complete of size 1.8 M dia X 3.0M deep. (CEJZ/STD-301/90 SHEET No 1/4to 4/4) 78 EXTERNAL ELECTRIC SUPPLY 79 Supply, installation, testing and commissioning of 11 KV, 630 Amp, 50 Hz, SF6 gas insulated, 21 KA/3 Sec 3 way Ring Main Unit of outdoor type, motor operated, extensible with 01 No. VCB 630 Amps as incommer and 02 Nos LBS as outgoing cable termination from front (Internal arc classification AFLR 21KA/1 Sec with bottom exhaust both for tank and cable box as per IEC:62271-200), enclosed in welded stainless tank having IP-67 degree of protection, leak rate of SF-6 gass less than 0.1% and tested as per IEC:62271-200, ring core type protection CT, line side isolator alongwith following technical specification:-(a) Electrical specification. (i) Nominal system voltage - 11 KV. (ii) Voltage variation on supply side - + 10 (iii) Corresponding higher system voltage - 12 KV. (iv) Transient condition - (-)20% or 10% combined variation of voltage and frequency. (v) Lightening impulse withstand voltage upto 75kVp. (vi) one minute dry/wet power frequency withstand voltage primiary - 28 KV. 80 (vii) Rated dynamic withstand current - 52.5 KA. (viii) No of short circuit operations at rated short circuit current of 21 KA for breaker - 50 Nos.(b) General specifications. All live parts, bus bars, shall be preferably be enclosed in non megnetic and non ferrite grade stainless steel tank grade SS-304 of minimum 2.5 thickness. The RMU shall be tested for internal arc test of 21 KA/1 Sec AFLR with bottom exhaust for safety of personnel for both tank as well as cable compartment as per IEC:62271-200. The outdoor enclosure shall have IP-55 protection for complete switchgears with top opening canopy & dedicated IP-55 cable compartment. The protection relay shall be for 3 o/c + 1 E/F (IDMT Type) self powered numerical protection relay with low and high set of over current and earth fault, MODBUS communicating alongwith RS-485 Port. Internal Arc classification should be with bottom exhaust only. The RMU should be SCADA compatible and trouble free operation at the temperature 40 degree C & above. 81 (C) Insulated Bus connected unit comprising of the following :(i)Air insulated enclosure with necessary bus connection via bushing VTs from manufacturer and according to IS:3156. (ii) Sinle phase bus PT for metering - 11 KV/rt3/110V/rt3, 50 VA, class 0.5. (iii)Auxillary transformer - 11 KV/230V AC, 1 KVA. (iv) Multifunction Meter - EM6400 NG class 0.5 for incomer(d) The following accessories should be included in deemed rate:(i) Antireflex operating hadle. (ii) Battery 24 V DC, 12 Ah. (iii) Battery charger 24V DC. (iv) Manometer with remote contact.Note : RMU should be manuctured, inspected by rep of the Acceptung Officer and invoiced from the OEM factory. 82 Supply, installation, testing and commissioning of Vacuum Circuit Breaker 630 Amps, having rupturing capacity 350 MVA, HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad constructed from Aluminium Zinc sheet steel of 2mm thickness for incomer as ICOG confirming to IEC-62271-200 complete with, overload and earth fault protection, ammeter, voltmeter complete as incomer circuit breaker all as specified and directed alongwith following technical specification:-(i) 630 Amps rating. (ii) Horizontolly draw out type. (iii) Trip road and have RoF type & Rack in Rack out motorised type. (iv) Motorised spring charging mechanism with integral spring charging hangle for manual spring charge. (v) Panel separation with every department like VCB, Metering, cable chamber & Bus bar chamber. 83 (vi) Cast resin current transformer 11 KV, 600-300/1+1A, core 1, class 0.5, 15VA wih metering and protection core including necessary control wiring & PT 11 KV, core-I class, 3 Pole, Core-II clause-0.5, 50 VA burden OVF 1.9 for 30 Second for metering & protection backed by HT & LT MCBs. (vii) Line PT should be mounted on rear side (top or bottom) of the panel. (viii) Accessories like local remote switch, breaker control through MCB, indicating lamp RYB, spring charging, DC supply healthy, breaker ON/OFF breaker in service/test, multi function meter with RS-485 port (EM-6400NG), Digital Ammeter and Volt Meter, (ix) Seprate master trip relay and anti pumping relay. (x) Comprehensive numerical protection relay should have built in integrated mimic compatible IEC-61850 for non-directional O/C, E/F,U/V, O/V protection type having following additional facility:-(a) Trip circuit supervision. (b) Distribution recorder. (c) Event log with date and time. 84 (c) Event log with date and time. (d) Conformal coating for harsh environment. (e) suitable to operate on 24 Volt DC for auxillary and control supply. (f) Fully internal arc type typed (25 KA for 1 second) as per latest IEC:62271-200. (g) Vocuum bottles should be tested for 100 full short circuit operations. (h) Mannal closing/tripping of CB with compartment door closed. (j) The panel shall be provided with power pack batter backup for not less than 10 minutes. (k) The height of the HT section should atleast be of 1400mm for human safety during the internal arc creation. (l) Breaker shall be provided with 6NO+1NC contacts for each position in service and test, (m) Wireless thermal sensor will be provided in each bus & each cable termination per panel, alongwith Zig-b contractor and the data of the same should be display on HMI. (n) The VCB shall be SCADA compatible. (o) The VCB interrupter, breaker & panel alongwith relay should be of same make for better coordination and better SCADA compatibility. 85 (E) Indicating lamps LED type(i) Breaker ON Red clolour - 01 No(ii) Breaker OFF Green Colour - 01 No(iii) Auto Trip indication amber colour- 01 No(iv) Trip circuit heathly clear - 01 No(v) Spring charged blue colour - 01 No(vi) RYB indication - 03 Nos(F) Accessories (i) Trip Neutral Close Switch - 01 No(ii) Space heater with thermostat - 01 No(iii) Local Remote Switch - 01 No(iv) 3 Pin Plug Connector - 01 No(v) MCB AC & DC - 02 Nos(G) Relays(i) Numerical relay 50/51/50N/51N, non communicable, non draw out type - 01 No(ii) Master trip relay - 01 No(iii) Auxillary relay for transformer (3 elecments) - 02 Nos 86 M & Lfor Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4mpa working pressure all as pecified and directed. 87 Supply, fixing, testing and commissioning of junction box incl AI bus bar with MCB SP 6A, 10 KA, C curve & PVC cable 2.5 sqmm 2 core weather proof, aluminium conductor upto 7.5 mtr length for connection for single or 3 incoming cable & for outgoing and single phase connection of secuirty light fitting from junction box , PVC conduit pipe upto junction box , enclosed in tehermo plastic enclouser,shock proof , weather , dust , rust & water proof internally embedded gasket with provision for cable entry of size 300x200x125mm alongwith MS clamps, through and incl suitable gland all as specified. 88 Supply, install , testing and commissioning of LT feeder pillar distribution panel board CPRI approved, outdoor type, weather/vermin proof, mae out of 3.15 mmm thick CRCA sheet duly powder coated of suitable size and medium channel 75mm base mounting frame double door factory assembled cubicle pattern modular and compartmentalized construction, floor mounted free standing type 3 phase and netural 200 Amps current carrying capacity aluminium bus bar with epoxy insulated coating with colour code and insulated support, cable galleries inter connecting busbar connection/linkage complete and conforming to IS : 8623 and IP 54 class of protection as per IS ; 2147 complete with the following accessories and suitable for housing one incoming MCCB and outgoing MCCBs of capacity as below completed and mounting the panel board on ground with PCC (1:3:6) , bedding upto a height 30cm above ground level complete all as specified and directed (OR CH/DH) 89 (a) Aluminium busbar 200 Amp for 3 phase & netural -1 Set. (b) MCCB 4 pole 100 Amps 25 KA at 415 V -1 No (incomig)(c) MCB TPN 32 amps, 10 KA , C curve -Nos (outgoing)-02 , spare-01). (d) MCB SP 16 A , 10KA , C Curve-2 Nos (for street lights). (e) Digital Voltmeter with selector switch 0 to 500 volt- 1 No. (f) Digital Ammeter with selector switch and CTs 0 to 500 Amps-01 No. (g) Timer switch with set of contactors - 1 No. (h) LED type indicator lamps (R 90 MANNING & OPERATION (M&O) UNDER PH-II 91 First year manning and operation of 750KWp Solar Power plant round the clock by providing following staff on all days including Sunday and Holiday for trouble free functioning of the installation at Adampur to ensure maximum solar energy is fed to grid including following:-(i) Trouble free operation of the solar power plant. (ii) Monitor the performance of the solar plant by data logging. (iii) Monthly report preperation and reporting to customer on performance of power plant. (iv) Maintainance of module- periodic cleaning of module through water. (v) Schedule maintainance of invertor. (vi) Frequent testing of plant equipment by walk down checks to internal condition of equipments such as module perfomance, inverter test monitoring, system testing etc. (vii) Careful logging of operation data and periodically processing it to determine abnormal slowly detoriating conditions. (viii) Attendto emergency break down/repair of the component without any delay. (ix) Careful control and supervision of operation conditions (wide and rapid variation in voltage and frequency conditions do contribute to increase maintainance). (x) Regulate routine maintainance work such as keeping equipment clean, cleaning of solar PV Module, proper maintainance of inverters, maintainance of LT/HT cable lugs, Panels, MCCBs, Joints, 92 Transformer, VCBs etc of any type/size and capacity. (xi) Spare parts maintainance including replacement of defective parts. (xii) Securing all equipments/materials against damage/theft etc. (xiii) Keeping complete area neat & clean through spray chemicals and cleaning of grass at regular interval of time. (xiv) Servicing and maintainance of SCADA System and taking printout of all the data from SCADA once daily. (xv) The thermal imaging of PV Panels should be taken for checking its healthiness once as directed by the Engg-in-Charge. (xvi) The shutdown time of interval should be monitored and recorded. Min staff (s) to be employed (a)Sopervisor : 01 No in one shift of 8 Hrs ( 0800 Hrs to 1600 Hrs) having diploma in electrical Engg and having good knowledge of SCADA system.(b) Electrician (ITI Electrical) - 01 No in one shift (0800 Hrs to 1600 Hrs) (c) Helper (Min 10th pass) : 01 No in three Shifts. (0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, and 2200 Hrs to 600 Hrs) 93 MANNING & OPERATION (M&O) UNDER PH-III 94 Second year manning and operation of 750KWp Solar Power plant round the clock by providing following staff on all days including Sunday and Holiday for trouble free functioning of the installation at Adampur to ensure maximum solar energy is fed to grid including following(i) Trouble free operation of the solar power plant. (ii) Monitor the performance of the solar plant by data logging. (iii) Monthly report preperation and reporting to customer on performance of power plant. (iv) Maintainance of module- periodic cleaning of module through water. (v) Schedule maintainance of invertor. (vi) Frequent testing of plant equipment by walk down checks to internal condition of equipments such as module perfomance, inverter test monitoring, system testing etc. (vii) Careful logging of operation data and periodically processing it to determine abnormal slowly detoriating conditions. (viii) Attendto emergency break down/repair of the component without any delay. (ix) Careful control and supervision of operation conditions (wide and rapid variation in voltage and frequency conditions do contribute to increase maintainance). (x) Regulate routine maintainance work such as keeping equipment clean, cleaning of solar PV Module, proper maintainance of inverters, maintainance of LT/HT cable lugs, Panels, MCCBs, Joints, 95 Transformer, VCBs etc of any type/size and capacity. (xi) Spare parts maintainance including replacement of defective parts. (xii) Securing all equipments/materials against damage/theft etc. (xiii) Keeping complete area neat & clean through spray chemicals and cleaning of grass at regular interval of time. (xiv) Servicing and maintainance of SCADA System and taking printout of all the data from SCADA once daily. (xv) The thermal imaging of PV Panels should be taken for checking its healthiness once as directed by the Engg-in-Charge. (xvi) The shutdown time of interval should be monitored and recorded. Min staff (s) to be employed (a)Sopervisor : 01 No in one shift of 8 Hrs ( 0800 Hrs to 1600 Hrs) having diploma in electrical Engg and having good knowledge of SCADA system. (b) Electrician (ITI Electrical) - 01 No in one shift (0800 Hrs to 1600 Hrs) (c) Helper (Min 10th pass) : 01 No in three Shifts. (0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, and 2200 Hrs to 600 Hrs)
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
41.
Power #9352674 Technical Bid
PROVIDING OF POWER SUPPLY to Transit Accommodation for Kashmiri Migrants at Allowpora FROM RECEIVING STATION IGC III Lassipora by way installation of dedicated 11 KV VCB Panel underUT Capex 2025-26- 1 Supply,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site including installation,Testing and Commissioning of 2 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Indoor) with O/C, E/F relays (IEC61850), Mimic Diagram,Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (SCADA Compatible) 3 GI Channel/Angle/Flat of sizes including clamps 4 11kV, 3 core 300 mm2 Aluminium round wire Armoured XLPE Cable 5 Termination Kit Indoor 300 sqmm 6 Termination Kit outdoor 300 sqmm 7 11 kV Isolator, Double Break,3-pole, 630 Amp, horizontal mounting Type, with Earth Switch. 8 Galvanized Nuts and Bolts 9 11 Mtr. Long Pole (ST-410 SP 56) 10 100 mm² ACSR Conductor 11 PG Clamps for 100 mm² ACSR Conductor 12 Earthing Complete by GI Pipe 40 mm3 mtr long through GI Strip 25x3 mm 13 Danger Plates with Clamps 14 Anti-Climbing Device with Clamps 15 Red Oxide 16 Aluminium Paint 17 Cement bottoming 1:2:4 mix as per Standards 0.66 cum/pole 18 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 19 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type 20 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 21 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
42.
Power #9344905 Technical Bid
Construction Of 3.15Mva33/11Kv R/Stn At Saddamandi By Way Of supply installation testing and commissioning Of Transformer Bay, 11Kv I/D Switchgear, Common Misc Works At 33/11Kv Level.- 1 SITC 33 kV TRANSFORMER BAY OF SINGLE BUS SCHEME 2 SUB‐STATION MAIN EQUIPMENT 3 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) with allied accessories and heavy duty pad clamps. 4 33 kV Isolator with Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 5 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 6 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 7 33 kV C&R Panelalong with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, DLMS Compliant with RS-485 port 8 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m 9 GI STEEL STRUCTURES 10 Galvanised Steel Structures 11 Galvanised Nuts & Bolts 12 SITC OF CONTROL CABLES 13 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 14 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 15 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 16 Lugs, Ferrules etc. 17 SITC OF CONDUCTOR & HARDWARE 18 Providing & Fixing 200 mm² ACSR Conductor Panther 19 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 20 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 21 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 22 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 23 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 24 SITC 11 kV INDOOR SWITCHGEAR OF 3.15MVA, 33/11 KV SUBSTATION 25 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (1+3)SET 26 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets) 27 11 kV3- Core XLPE 185 mm² armoured, FRLS 28 11 kV3-Core XLPE 120 mm² armoured, FRLS 29 11 kV Indoor Heat Shrinkable Cable 185 mm² Termination Kits 30 11 kV Outdoor Heat Shrinkable Cable 185 mm² Termination Kits 31 11 kV Indoor Heat Shrinkable Cable120 mm²Termination Kits 32 11 kV Outdoor Heat Shrinkable Cable120 mm² Termination Kits 33 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. 34 9 Mtr. Long Pole(ST-410 SP33) 35 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 36 Galvanisedironof sorts 37 100 KVA, 33/0.04 KV, 3-Phase Distribution Transformer with Bimetallic Terminal connectors Energy Level -2 (Aliminium wound) (1no. Spare) 38 120 mm²PVCLT Cable 4 Core, armoured, FRLS 39 Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole 40 Earthing of 100 KVA Substation-Excavation of earht pit of dia 650 mm & depth 3000 mm installation of earthing pipe of 40 mm Nominal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239 GI Strip[ for neutral earthing of ize 75 mm x 10 mm & 50 mm x6 mm for connection of transformer body, G.O set & lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. 41 Supply ,Installation Testing and Commissioning of Earthing Complete by GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm. 42 MCCB ‐ 200 Amps 43 SITC OF COMMON MISCELLENOUS WORKS IN 33/11kV SUBSTATION 44 G.I Chainlink Fencing of 33kv yard by way of mass concreting in foundations and chainlink fencing of 6 ft height using G.I Angle of size 65x65x6mm and G.I Flat iron 50x6mm 45 RCC Cable Duct for laying of 11 KV XLPE Cable from Power transformer to Control Room and Control Room to O/G Structures as per REC Approved Standard Drawing. 46 33/11 kV RCC Power Transformer Foundation (1:2:4) as per REC Approved Standarddrawing foundation complete job for 3.15 MVA Power Transformer 47 33 kV RCC Equipment foundation and Gantry foundationas per REC Approved Standarddrawing (VCB, Isolators, CTs, PIs, LAs etc) complete job 48 Earthing Mat using ( GI Flat 75 x 8mm) and (GI earth rod spikes 2.5 m long 20 mm dia), yard area, as per REC Standerd 49 Earthing Electrode ( 3m long 40mm dia GI pipe) through GI strip (50x6)mm for equipments 50 33 kV Yard concreting and metalling, yard area by providing, supply & laying 100mm thick PCC 1:4:8 using 20mm normal course aggregating and spreading 100mm three layer of 20mm single sized crushed/broken stone, as per REC Standerd 51 SITC of 120 Watts LED Street lights of following watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on 13mtr ST Poles including necessaryboxes/fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.) 52 Cement Conceret R/B Wall in1:3:6 mix as per site requirement on the direction of concerned Engineer 53 SITC OF COMMON MISCELLANEOUS EQUIPMENTS 33/11kV SUBSTATION 54 a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelenecopolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply . 55 Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Doublebusbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories 56 Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCBs (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories 57 Providing of Bolt cutter of Taparia make BC-42 with allied accessories. 58 Providing of Rubber Mat 1mx2m 19mm thick 59 Providing of Fire ExtingiusherCo₂/ABCType of 4.5 kg capacity for controlroom 60 Providing of 3Sand Bucket Fire Extingiusherwith metallic stand andidentification plates 61 Providing of Industrial safety Helmet 62 Providing of Rubber Gloves for 33 kV level 63 Providing of Rubber Gloves for 11kV level 64 Providing of Industrial Safety Belt with comfort foam reinforment 65 Providing of Safety volcanized rubber Shoes 66 Providing of Telescopic Cabron fibre Earthing rod (set of 3 rods) 67 Providing of HV Detectors all voltages with fibre rod 68 Providing of Chrome vanadium forged Spanners of 10mm to 32mm sizering/u shaped. (set of 10 No.s) 69 Providing of Forged Adjustable wrench of 22mm and 32mm size 70 Providing of Screw drivers setflat cum star bit type dual end (set of 8 no.sof different sizes) 71 Providing of Nose Plier 72 Providing of Normal Plier 73 Providing of Sledge hammer of 2Kg with handle 74 Providing of forged Chisel long shank type 75 Providing of HSS Cabron steel Hawk saw with frame and set of 6 blade with two sided teeths 76 Providing of Measuring tape of 12 feet spring loaded 77 Providing of Precise 1 feet long bubble based water level 78 Providing of 600 watt hand drill with drill bits of HSS Hammer type 79 Providing of Tool Kit case plastic of Harry-kerry make of 2.5x1x1.5 feet dimensions with different chambers 80 Providing of Clamp meter with multi measuring parametersMarkoni/motwane/fluke make 81 Providing of Screw driver tester neon lamp based 82 Providing and fixing of industrial heavy duty chain block of 1 Ton capacitywith allied accessories complete 83 Providing of Chrome make socket set with ratchet and extension bars of10mm-32mm size sockets with allied accessories 84 Providing of Aluminum industrial ladder split 40 feet extension type withallied accessories 85 Providing of foldable multi-purpose aluminium ladder 86 Office Steel Chairs wih Armrest 87 Office Table of Standard Size with Sufficient Drawers 88 Office Almirah With Locker of reputed make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
43.
Power #9344903 Technical Bid
CONSTRUCTION OF 3.15MVA33/11KV R/STN AT UDHAN BY WAY OF supply installation testing and commissioning OF TRANSFORMER BAY, 11KV I/D SWITCHGEAR, COMMON MISC WORKS AT 33/11KV LEVEL.- 1 SITC 33 kV TRANSFORMER BAY OF SINGLE BUS SCHEME 2 SUB‐STATION MAIN EQUIPMENT 3 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) with allied accessories and heavy duty pad clamps. 4 33 kV Isolator with Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 5 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 6 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 7 33 kV C&R Panelalong with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, DLMS Compliant with RS-485 port 8 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m 9 GI STEEL STRUCTURES 10 Galvanised Steel Structures 11 Galvanised Nuts & Bolts 12 SITC OF CONTROL CABLES 13 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 14 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 15 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 16 Lugs, Ferrules etc. 17 SITC OF CONDUCTOR & HARDWARE 18 Providing & Fixing 200 mm² ACSR Conductor Panther 19 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 20 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 21 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 22 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 23 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 24 SITC 11 kV INDOOR SWITCHGEAR OF 3.15MVA, 33/11 KV SUBSTATION 25 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (1+3)SET 26 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets) 27 11 kV3- Core XLPE 185 mm² armoured, FRLS 28 11 kV3-Core XLPE 120 mm² armoured, FRLS 29 11 kV Indoor Heat Shrinkable Cable 185 mm² Termination Kits 30 11 kV Outdoor Heat Shrinkable Cable 185 mm² Termination Kits 31 11 kV Indoor Heat Shrinkable Cable120 mm²Termination Kits 32 11 kV Outdoor Heat Shrinkable Cable120 mm² Termination Kits 33 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. 34 9 Mtr. Long Pole(ST-410 SP33) 35 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 36 Galvanisedironof sorts 37 100 KVA, 33/0.04 KV, 3-Phase Distribution Transformer with Bimetallic Terminal connectors Energy Level -2 (Aliminium wound) (1no. Spare) 38 120 mm²PVCLT Cable 4 Core, armoured, FRLS 39 Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole 40 Earthing of 100 KVA Substation-Excavation of earht pit of dia 650 mm & depth 3000 mm installation of earthing pipe of 40 mm Nominal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239 GI Strip[ for neutral earthing of ize 75 mm x 10 mm & 50 mm x6 mm for connection of transformer body, G.O set & lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. 41 Supply ,Installation Testing and Commissioning of Earthing Complete by GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm. 42 MCCB ‐ 200 Amps 43 SITC OF COMMON MISCELLENOUS WORKS IN 33/11kV SUBSTATION 44 G.I Chainlink Fencing of 33kv yard by way of mass concreting in foundations and chainlink fencing of 6 ft height using G.I Angle of size 65x65x6mm and G.I Flat iron 50x6mm 45 RCC Cable Duct for laying of 11 KV XLPE Cable from Power transformer to Control Room and Control Room to O/G Structures as per REC Approved Standard Drawing. 46 33/11 kV RCC Power Transformer Foundation (1:2:4) as per REC Approved Standarddrawing foundation complete job for 3.15 MVA Power Transformer 47 33 kV RCC Equipment foundation and Gantry foundationas per REC Approved Standarddrawing (VCB, Isolators, CTs, PIs, LAs etc) complete job 48 Earthing Mat using ( GI Flat 75 x 8mm) and (GI earth rod spikes 2.5 m long 20 mm dia), yard area, as per REC Standerd 49 Earthing Electrode ( 3m long 40mm dia GI pipe) through GI strip (50x6)mm for equipments 50 33 kV Yard concreting and metalling, yard area by providing, supply & laying 100mm thick PCC 1:4:8 using 20mm normal course aggregating and spreading 100mm three layer of 20mm single sized crushed/broken stone, as per REC Standerd 51 SITC of 120 Watts LED Street lights of following watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on 13mtr ST Poles including necessaryboxes/fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.) 52 Cement Conceret R/B Wall in1:3:6 mix as per site requirement on the direction of concerned Engineer 53 SITC OF COMMON MISCELLANEOUS EQUIPMENTS 33/11kV SUBSTATION 54 a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelenecopolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply . 55 Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Doublebusbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories 56 Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCBs (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories 57 Providing of Bolt cutter of Taparia make BC-42 with allied accessories. 58 Providing of Rubber Mat 1mx2m 19mm thick 59 Providing of Fire ExtingiusherCo₂/ABCType of 4.5 kg capacity for controlroom 60 Providing of 3Sand Bucket Fire Extingiusherwith metallic stand andidentification plates 61 Providing of Industrial safety Helmet 62 Providing of Rubber Gloves for 33 kV level 63 Providing of Rubber Gloves for 11kV level 64 Providing of Industrial Safety Belt with comfort foam reinforment 65 Providing of Safety volcanized rubber Shoes 66 Providing of Telescopic Cabron fibre Earthing rod (set of 3 rods) 67 Providing of HV Detectors all voltages with fibre rod 68 Providing of Chrome vanadium forged Spanners of 10mm to 32mm sizering/u shaped. (set of 10 No.s) 69 Providing of Forged Adjustable wrench of 22mm and 32mm size 70 Providing of Screw drivers setflat cum star bit type dual end (set of 8 no.sof different sizes) 71 Providing of Nose Plier 72 Providing of Normal Plier 73 Providing of Sledge hammer of 2Kg with handle 74 Providing of forged Chisel long shank type 75 Providing of HSS Cabron steel Hawk saw with frame and set of 6 blade with two sided teeths 76 Providing of Measuring tape of 12 feet spring loaded 77 Providing of Precise 1 feet long bubble based water level 78 Providing of 600 watt hand drill with drill bits of HSS Hammer type 79 Providing of Tool Kit case plastic of Harry-kerry make of 2.5x1x1.5 feet dimensions with different chambers 80 Providing of Clamp meter with multi measuring parametersMarkoni/motwane/fluke make 81 Providing of Screw driver tester neon lamp based 82 Providing and fixing of industrial heavy duty chain block of 1 Ton capacitywith allied accessories complete 83 Providing of Chrome make socket set with ratchet and extension bars of10mm-32mm size sockets with allied accessories 84 Providing of Aluminum industrial ladder split 40 feet extension type withallied accessories 85 Providing of foldable multi-purpose aluminium ladder 86 Office Steel Chairs wih Armrest 87 Office Table of Standard Size with Sufficient Drawers 88 Office Almirah With Locker of reputed make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
44.
Power #9334435 Technical Bid
Tender For Creation Of Receiving Stations- 1 A-SUPPLY PART-6.30 MVA HASTI 2 33 KV LINE BAY OF SINGLE BUS SCHEME (INCLUDING ALL FOUNDATION WORKS) 3 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 4 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 5 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 6 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 7 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 8 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 9 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 10 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 11 STEEL STRUCTURES/PIPE STRUCTURE(INCLUDING ALL FOUNDATION WORKS) 12 Pipe Nominal bore 200, 5.9 mm thick 13 Galvanised steel structures 14 Galvanized nuts and bolts 15 CONTROL CABLES(INCLUDING ALL FOUNDATION WORKS) 16 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 17 4 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 18 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 19 Lugs & Ferrules etc. 20 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 21 ACSR Conductor Panther 22 T-Clamp 23 Single Tension fitting 24 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 25 Earth Wire 7/4 sqmm 26 G.I Flat 50*6 mm 27 SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY(INCLUDING ALL FOUNDATION WORKS) 28 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 29 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 30 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 31 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 32 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 33 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 34 STEEL STRUCTURES(INCLUDING ALL FOUNDATION WORKS) 35 Pipe Nominal bore 200, 5.9 mm thick 36 Galvanised steel structures 37 Galvanized nuts and bolts 38 CONTROL CABLES 39 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 40 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 41 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 42 Lugs & Ferrules etc. 43 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 44 ACSR Conductor Panther 45 T-Clamp 46 G.I Flat 50*6 mm 47 33/11 KV, 6.30 MVA Power Transformer(INCLUDING ALL FOUNDATION WORKS) 48 33/11KV ONAN,6.30MVA Copper wound,Outdoor type,Conventional Power transformer,Oil filled with OLTC and all accessories including HT and LT Terminal connections with busbars 49 12 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 50 6 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 51 2 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 52 Cost for 11 KV Indoor Switchgear of 33/11 kv Substation (Transformer Bay Scheme) 53 11 KV VCB Panel Board ( 12KV,1250A,25KA, Outdoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector Smart meter-5A,DLMS Compliant with RS-485 Port1 Incoming & 4 outgoings 54 11KV Gapless Surge Arrestor,9KV,10KA LA With polymer HousingStation Type 55 11KV (UE)XLPE Power Cables (Armoured) 56 11 kV400 mm² Three Core XLPE Cable (with one spare length) armoured, FRLS 57 11 kV (UE) 3-Core XLPE 120 mm² armoured, FRLS 58 11KVHeat shrink termination Cable Kits (Indoor) 400 mm square (3-core) 59 11KV Heat shrink termination Cable Kits (Outdoor) 400 mm square (3-core) 60 11KV Heat shrink termination Cable Kits (Indoor) 120 mm square(one spare) (3-core) 61 11KV Heat shrink terminationCable Kits (Outdoor) 120 mm square (one spare) (3-core) 62 11 KV isolator, double break, 3 pole, 600 Amp. Horizental mounting type with earth switch Complete 63 11KV GO Set, AB switch 3 phase, 3 pole, 400 Amps. 64 100 KVA, 11/.433 KV,Auxiliary Transformer,3 Phase Distribution Transformer with bimetallic terminal connectors ,energy level -2,Al Wound. 65 StT Poles 9 mtrs long 66 Galvanised iron of sorts 67 120 mm2 PVC 4 core cable,Armoured FRLS 68 MCCB 200 Amp 69 Cement bottomng 1:2:4 mix as per REC standards 0.5cum per pole 70 Earthing of 100KVA substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm& 50 mm x 6 mmfor connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 71 Earthing complete GI pipe 40 mm or GI rod 20mm 2.5 mtr long through G.I Strip 72 COMMON MISCELLANEOUS EQUIPMENTS 73 a) Battery Bank 30 V, 100 AH, of 15 No. cells of 2 V each, sealed maintenance free VRLA type, high impact Polyprophelene copolymer container, flame retardant with stand 74 b) 30 V, 100 AH, float-cum-boost charger with full wave rectification for 220 V, 1 phase, 50 HZ AC input supply. 75 Distribution panel (30V, DC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 for two number battery incoming supplywith 2No. 63 Amp. DP MCB for incoming supplydouble bus bar of adequate size,twelve number DP DC MCB(0-32A) including indication lamp and cables and other accessories 76 Distribution panel (415 V, AC)made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 200A Switch fuse disconnector for incoming supply and five numbers TPN MCBs(16-125A) and five number DP MCB(0-32A),rectangular bus bar suitable for 200 A continous supply including indication lamp cables and other accessories. 77 Telecommunication facilities including cctvs set (4nos cameras ) LED Display (32) 78 CIVIL WORKS 79 Compound walling of identified land by way of Mass Concrete in Foundation and 228mm bricks of 2M height 80 Chain-link Fencing of 33kv Yard of Substation by way of Mass Concrete in Foundations and chain-link fencing of 6 ft height. 81 33/11kv power Transformer Foundation 82 33kv Equipment Foundation and gantry foundation 83 Earthing Mat complete job GI flat 50x8 mm 84 Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips 85 33kv Yard Concreting / Metalling 86 Underground Water tank 10000 Ltrs. 87 Overhead water tank 2000Ltr 88 Control room Building including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 89 Shift Quarters for Je and SBA including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 90 Truss for control room building 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing 158 sqm 91 Development of identified land by way of removing weeds, wild grass and undulation if any, ornamental land scraping and growing of ornamental trees in un built areas and road sides and development of road along with surface drain. 92 Construction of semi Pucca B/Wall of 2.0 Mtr. Height (Length=100 mtr) 93 Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone 94 Construction of Pucca Drain 95 Yard Lighting ( 6 Nos yard and 02 Nos CR back side) on 9m Long Poles 96 CAPACITOR BANK 97 12 kV Capacitor Bank with VCB Panel with complete arrancement for conection with 11 kV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories. 98 SINGLE BUS OUT (INCLUDING ALL FOUNDATION WORKS) 99 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 100 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 101 33 KV Current Transformer (Single Phase,Multi ratio,multi core ,Outdoor) 102 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 103 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 PHASE Trivector meter DLMS compliant RS 485 port 104 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 105 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 106 STEEL STRUCTURES(INCLUDING ALL FOUNDATION WORKS) 107 Galvanised steel structures 108 Galvanized nuts and bolts 109 Pipe Nominal bore 200, 5.9 mm thick 110 CONTROL CABLES 111 10 /12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 112 8 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 113 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 114 Lugs & Ferrules etc. 115 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 116 ACSR Conductor Panther 117 T-Clamp 118 Single Tension fitting 119 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 120 Earth Wire 7/4 sqmm 121 G.I Flat 50*06 mm 122 33 KV LINE (INCLUDING ALL FOUNDATION WORKS) 123 11 Mtr. Long ST Pole(For new line) ST-410 SP56 124 GI Channel X-arm including clamps and braces 125 100 mm² ACSR DogConductor 126 PG Clamps for 100 mm² ACSR Conductor 127 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 128 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings 129 Galvinized Nuts and Bolts. 130 Danger Plates with Clamps 131 Anti-Climbing Device with Clamps 132 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 133 Red Oxide 134 Aluminium Paint 135 Cement bottoming 1:2:4 mix as per REC standards .6cum /pole 136 Stone Pad (300 mm x 300 mmx 75 mm) 137 Aluminium Jointing Sleeves 138 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 139 Guard netting 140 A-SUPPLY PART-6.30 MVA DOOL 141 33 KV LINE BAY OF SINGLE BUS SCHEME(INCLUDING ALL FOUNDATION WORKS) 142 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 143 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 144 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 145 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 146 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 147 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 148 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 149 STEEL STRUCTURES/PIPE STRUCTURE(INCLUDING ALL FOUNDATION WORKS) 150 Pipe Nominal bore 200, 5.9 mm thick 151 Galvanised steel structures 152 Galvanized nuts and bolts 153 CONTROL CABLES 154 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 155 4 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 156 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 157 Lugs & Ferrules etc. 158 CONDUCTOR AND HARDWARE 159 ACSR Conductor Panther 160 T-Clamp 161 Single Tension fitting 162 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 163 Earth Wire 7/4 sqmm 164 G.I Flat 50*6 mm 165 SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY(INCLUDING ALL FOUNDATION WORKS) 166 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 167 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 168 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 169 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 170 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 171 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 172 STEEL STRUCTURES(INCLUDING ALL FOUNDATION WORKS) 173 Pipe Nominal bore 200, 5.9 mm thick 174 Galvanised steel structures 175 Galvanized nuts and bolts 176 CONTROL CABLES 177 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 178 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 179 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 180 Lugs & Ferrules etc. 181 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 182 ACSR Conductor Panther 183 T-Clamp 184 G.I Flat 50*6 mm 185 33/11 KV, 6.30 MVA Power Transformer(INCLUDING ALL FOUNDATION WORKS) 186 33/11KV ONAN,6.30MVA Copper wound,Outdoor type,Conventional Power transformer,Oil filled with OLTC and all accessories including HT and LT Terminal connections with busbars 187 12 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 188 6 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 189 2 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 190 Cost for 11 KV Indoor Switchgear of 33/11 kv Substation (Transformer Bay Scheme) 191 11 KV VCB Panel Board ( 12KV,1250A,25KA, Outdoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector Smart meter-5A,DLMS Compliant with RS-485 Port1 Incoming & 4 outgoings 192 11KV Gapless Surge Arrestor,9KV,10KA LA With polymer HousingStation Type 193 11KV (UE)XLPE Power Cables (Armoured) 194 11 kV400 mm² 3-Core XLPE Cable (with one spare length) armoured, FRLS 195 11 kV (UE) 3-Core XLPE 120 mm² armoured, FRLS 196 11KVHeat shrink termination Cable Kits (Indoor) 400 Sqmm square (3-core) 197 11KV Heat shrink termination Cable Kits (Outdoor) 400 mm square (3-core) 198 11KV Heat shrink termination Cable Kits (Indoor) 120 mm square(one spare) (3-core) 199 11KV Heat shrink terminationCable Kits (Outdoor) 120 mm square (one spare) (3-core) 200 11 KV isolator, double break, 3 pole, 600 Amp. Horizental mounting type with earth switch Complete 201 11KV GO Set, AB switch 3 phase, 3 pole, 400 Amps. 202 100 KVA, 11/.433 KV,Auxiliary Transformer,3 Phase Distribution Transformer with bimetallic terminal connectors ,energy level -2,Al Wound. 203 StT Poles 9 mtrs long 204 Galvanised iron of sorts 205 120 mm2 PVC 4 core cable,Armoured FRLS 206 MCCB 200 Amp 207 Cement bottomng 1:2:4 mix as per REC standards 0.5cum per pole 208 Earthing of 100KVA substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm& 50 mm x 6 mmfor connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 209 Earthing complete GI pipe 40 mm or GI rod 20mm 2.5 mtr long through G.I Strip 210 COMMON MISCELLANEOUS EQUIPMENTS 211 a) Battery Bank 30 V, 100 AH, of 15 No. cells of 2 V each, sealed maintenance free VRLA type, high impact Polyprophelene copolymer container, flame retardant with stand 212 b) 30 V, 100 AH, float-cum-boost charger with full wave rectification for 220 V, 1 phase, 50 HZ AC input supply. 213 Distribution panel (30V, DC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 for two number battery incoming supplywith 2No. 63 Amp. DP MCB for incoming supplydouble bus bar of adequate size,twelve number DP DC MCB(0-32A) including indication lamp and cables and other accessories 214 Distribution panel (415 V, AC)made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 200A Switch fuse disconnector for incoming supply and five numbers TPN MCBs(16-125A) and five number DP MCB(0-32A),rectangular bus bar suitable for 200 A continous supply including indication lamp cables and other accessories. 215 Telecommunication facilities including cctvs set (4nos cameras ) LED Display (32) 216 CIVIL WORKS 217 Compound walling of identified land by way of Mass Concrete in Foundation and 228mm bricks of 2M height 218 Chain-link Fencing of 33kv Yard of Substation by way of Mass Concrete in Foundations and chain-link fencing of 6 ft height. 219 33/11kv power Transformer Foundation 220 33kv Equipment Foundation and gantry foundation 221 Earthing Mat complete job GI flat 50x8 mm 222 Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips 223 33kv Yard Concreting / Metalling 224 Underground Water tank 10000 Ltrs. 225 Overhead water tank 2000Ltr 226 Control room Building including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 227 Shift Quarters for Je and SBA including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 228 Truss for control room building 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing 158 sqm 229 Development of identified land by way of removing weeds, wild grass and undulation if any, ornamental land scraping and growing of ornamental trees in un built areas and road sides and development of road along with surface drain. 230 Construction of semi Pucca B/Wall of 2.0 Mtr. Height (Length=100 mtr) 231 Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone 232 Construction of Pucca Drain 233 Yard Lighting ( 6 Nos yard and 02 Nos CR back side) on 9m Long Poles 234 ERECTION OF 33 KV LINEDOOL(INCLUDING ALL FOUNDATION WORKS) 235 11 Mtr. Long ST Pole(For new line) ST-410 SP56 236 GI Channel X-arm including clamps and braces 237 100 mm² ACSR DogConductor 238 PG Clamps for 100 mm² ACSR Conductor 239 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 240 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings 241 Galvinized Nuts and Bolts. 242 Danger Plates with Clamps 243 Anti-Climbing Device with Clamps 244 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 245 Red Oxide 246 Aluminium Paint 247 Cement bottoming 1:2:4 mix as per REC standards .6cum /pole 248 Stone Pad (300 mm x 300 mmx 75 mm) 249 Aluminium Jointing Sleeves 250 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 251 Guard netting 252 B-ERECTION PART-6.30 MVA HASTI 253 33 KV LINE BAY OF SINGLE BUS SCHEME (INCLUDING ALL FOUNDATION WORKS) 254 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 255 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 256 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 257 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 258 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 259 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 260 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 261 33 kv Post Insulators polymer type , 36 KV , 235 KV impulse, creepage distance 1224 mm 262 STEEL STRUCTURES/PIPE STRUCTURE(INCLUDING ALL FOUNDATION WORKS) 263 Pipe Nominal bore 200, 5.9 mm thick 264 Galvanised steel structures 265 Galvanized nuts and bolts 266 CONTROL CABLES(INCLUDING ALL FOUNDATION WORKS) 267 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 268 4 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 269 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 270 Lugs & Ferrules etc. 271 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 272 ACSR Conductor Panther 273 T-Clamp 274 Single Tension fitting 275 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 276 Earth Wire 7/4 sqmm 277 G.I Flat 50*6 mm 278 SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY(INCLUDING ALL FOUNDATION WORKS) 279 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 280 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 281 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 282 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 283 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 284 33 KVPost Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 285 STEEL STRUCTURES(INCLUDING ALL FOUNDATION WORKS) 286 Pipe Nominal bore 200, 5.9 mm thick 287 Galvanised steel structures 288 Galvanized nuts and bolts 289 CONTROL CABLES 290 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 291 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 292 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 293 Lugs & Ferrules etc. 294 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 295 ACSR Conductor Panther 296 T-Clamp 297 G.I Flat 50*6 mm 298 33/11 KV, 6.30 MVA Power Transformer(INCLUDING ALL FOUNDATION WORKS) 299 33/11KV ONAN,6.30MVA Copper wound,Outdoor type,Conventional Power transformer,Oil filled with OLTC and all accessories including HT and LT Terminal connections with busbars 300 12 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 301 6 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 302 2 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 303 Cost for 11 KV Indoor Switchgear of 33/11 kv Substation (Transformer Bay Scheme) 304 11 KV VCB Panel Board ( 12KV,1250A,25KA, Outdoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector Smart meter-5A,DLMS Compliant with RS-485 Port1 Incoming & 4 outgoings 305 11KV Gapless Surge Arrestor,9KV,10KA LA with polymer HousingStation Type 306 11KV (UE)XLPE Power Cables (Armoured) 307 11 kV400 mm² Three Core XLPE Cable (with one spare length) armoured, FRLS 308 11 kV (UE) 3-Core XLPE 120 mm² armoured, FRLS 309 11KVHeat shrink termination Cable Kits (Indoor) 400 mm square (3-core) 310 11KV Heat shrink termination Cable Kits (Outdoor) 400 mm square (3-core) 311 11KV Heat shrink termination Cable Kits (Indoor) 120 mm square(one spare) (3-core) 312 11KV Heat shrink terminationCable Kits (Outdoor) 120 mm square (one spare) (3-core) 313 11 KV isolator, double break, 3 pole, 600 Amp. Horizental mounting type with earth switch Complete 314 11KV GO Set, AB switch 3 phase, 3 pole, 400 Amps. 315 100 KVA, 11/.433 KV,Auxiliary Transformer,3 Phase Distribution Transformer with bimetallic terminal connectors ,energy level -2,Al Wound. 316 StT Poles 9 mtrs long 317 Galvanised iron of sorts 318 120 mm2 PVC 4 core cable,Armoured FRLS 319 MCCB 200 Amp 320 Cement bottomng 1:2:4 mix as per REC standards 0.5cum per pole 321 Earthing of 100KVA substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm& 50 mm x 6 mmfor connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 322 Earthing complete GI pipe 40 mm or GI rod 20mm 2.5 mtr long through G.I Strip 323 COMMON MISCELLANEOUS EQUIPMENTS 324 a) Battery Bank 30 V, 100 AH, of 15 No. cells of 2 V each, sealed maintenance free VRLA type, high impact Polyprophelene copolymer container, flame retardant with stand 325 b) 30 V, 100 AH, float-cum-boost charger with full wave rectification for 220 V, 1 phase, 50 HZ AC input supply. 326 Distribution panel (30V, DC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 for two number battery incoming supplywith 2No. 63 Amp. DP MCB for incoming supplydouble bus bar of adequate size,twelve number DP DC MCB(0-32A) including indication lamp and cables and other accessories 327 Distribution panel (415 V, AC)made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 200A Switch fuse disconnector for incoming supply and five numbers TPN MCBs(16-125A) and five number DP MCB(0-32A),rectangular bus bar suitable for 200 A continous supply including indication lamp cables and other accessories. 328 Telecommunication facilities including cctvs set (4nos cameras ) LED Display (32) 329 CIVIL WORKS 330 Compound walling of identified land by way of Mass Concrete in Foundation and 228mm bricks of 2M height 331 Chain-link Fencing of 33kv Yard of Substation by way of Mass Concrete in Foundations and chain-link fencing of 6 ft height. 332 33/11kv power Transformer Foundation 333 33kv Equipment Foundation and gantry foundation 334 Earthing Mat complete job GI flat 50x8 mm 335 Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips 336 33kv Yard Concreting / Metalling 337 Underground Water tank 10000 Ltrs. 338 Overhead water tank 2000Ltr 339 Control room Building including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 340 Shift Quarters for Je and SBA including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 341 Truss for control room building 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing 158 sqm 342 Development of identified land by way of removing weeds, wild grass and undulation if any, ornamental land scraping and growing of ornamental trees in un built areas and road sides and development of road along with surface drain. 343 Construction of semi Pucca B/Wall of 2.0 Mtr. Height (Length=100 mtr) 344 Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone 345 Construction of Pucca Drain 346 Yard Lighting ( 6 Nos yard and 02 Nos CR back side) on 9m Long Poles 347 CAPACITOR BANK 348 12 kV Capacitor Bank with VCB Panel with complete arrancement for conection with 11 kV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories. 349 SINGLE BUS OUT (INCLUDING ALL FOUNDATION WORKS) 350 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 351 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 352 33 KV Current Transformer (Single Phase,Multi ratio,multi core ,Outdoor) 353 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 354 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 PHASE Trivector meter DLMS compliant RS 485 port 355 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 356 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 357 STEEL STRUCTURES(INCLUDING ALL FOUNDATION WORKS) 358 Galvanised steel structures 359 Galvanized nuts and bolts 360 Pipe Nominal bore 200, 5.9 mm thick 361 CONTROL CABLES 362 10 /12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 363 8 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 364 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 365 Lugs & Ferrules etc. 366 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 367 ACSR Conductor Panther 368 T-Clamp 369 Single Tension fitting 370 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 371 Earth Wire 7/4 sqmm 372 G.I Flat 50*06 mm 373 33 KV LINE (INCLUDING ALL FOUNDATION WORKS) 374 11 Mtr. Long ST Pole(For new line) ST-410 SP56 375 GI Channel X-arm including clamps and braces 376 100 mm² ACSR DogConductor 377 PG Clamps for 100 mm² ACSR Conductor 378 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 379 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings 380 Galvinized Nuts and Bolts. 381 Danger Plates with Clamps 382 Anti-Climbing Device with Clamps 383 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 384 Red Oxide 385 Aluminium Paint 386 Cement bottoming 1:2:4 mix as per REC standards .6cum /pole 387 Stone Pad (300 mm x 300 mmx 75 mm) 388 Aluminium Jointing Sleeves 389 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 390 Guard netting 391 B-ERECTION PART-6.30 MVA DOOL 392 33 KV LINE BAY OF SINGLE BUS SCHEME(INCLUDING ALL FOUNDATION WORKS) 393 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 394 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 395 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 396 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 397 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 398 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 399 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 400 STEEL STRUCTURES/PIPE STRUCTURE(INCLUDING ALL FOUNDATION WORKS) 401 Pipe Nominal bore 200, 5.9 mm thick 402 Galvanised steel structures 403 Galvanized nuts and bolts 404 CONTROL CABLES 405 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 406 4 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 407 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 408 Lugs & Ferrules etc. 409 CONDUCTOR AND HARDWARE 410 ACSR Conductor Panther 411 T-Clamp 412 Single Tension fitting 413 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 414 Earth Wire 7/4 sqmm 415 G.I Flat 50*6 mm 416 SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY(INCLUDING ALL FOUNDATION WORKS) 417 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 418 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 419 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 420 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 421 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 422 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 423 STEEL STRUCTURES(INCLUDING ALL FOUNDATION WORKS) 424 Pipe Nominal bore 200, 5.9 mm thick 425 Galvanised steel structures 426 Galvanized nuts and bolts 427 CONTROL CABLES 428 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 429 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 430 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 431 Lugs & Ferrules etc. 432 CONDUCTOR AND HARDWARE(INCLUDING ALL FOUNDATION WORKS) 433 ACSR Conductor Panther 434 T-Clamp 435 G.I Flat 50*6 mm 436 33/11 KV, 6.30 MVA Power Transformer(INCLUDING ALL FOUNDATION WORKS) 437 33/11KV ONAN,6.30MVA Copper wound,Outdoor type,Conventional Power transformer,Oil filled with OLTC and all accessories including HT and LT Terminal connections with busbars 438 12 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 439 6 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 440 2 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 441 Cost for 11 KV Indoor Switchgear of 33/11 kv Substation (Transformer Bay Scheme) 442 11 KV VCB Panel Board ( 12KV,1250A,25KA, Outdoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector Smart meter-5A,DLMS Compliant with RS-485 Port(1 Incoming & 4 outgoings ) 443 11KV Gapless Surge Arrestor,9KV,10KA LA With polymer HousingStation Type 444 11KV (UE)XLPE Power Cables (Armoured) 445 11 kV400 mm² 3-Core XLPE Cable (with one spare length) armoured, FRLS 446 11 kV (UE) 3-Core XLPE 120 mm² armoured, FRLS 447 11KVHeat shrink termination Cable Kits (Indoor) 400 mm square (3-core) 448 11KV Heat shrink termination Cable Kits (Outdoor) 400mm square (3-core) 449 11KV Heat shrink termination Cable Kits (Indoor) 120 mm square(one spare) (3-core) 450 11KV Heat shrink terminationCable Kits (Outdoor) 120 mm square (one spare) (3-core) 451 11 KV isolator, double break, 3 pole, 600 Amp. Horizental mounting type with earth switch Complete 452 11KV GO Set, AB switch 3 phase, 3 pole, 400 Amps. 453 100 KVA, 11/.433 KV,Auxiliary Transformer,3 Phase Distribution Transformer with bimetallic terminal connectors ,energy level -2,Al Wound. 454 StT Poles 9 mtrs long 455 Galvanised iron of sorts 456 120 mm2 PVC 4 core cable,Armoured FRLS 457 MCCB 200 Amp 458 Cement bottomng 1:2:4 mix as per REC standards 0.5cum per pole 459 Earthing of 100KVA substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm& 50 mm x 6 mmfor connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 460 Earthing complete GI pipe 40 mm or GI rod 20mm 2.5 mtr long through G.I Strip 461 COMMON MISCELLANEOUS EQUIPMENTS 462 a) Battery Bank 30 V, 100 AH, of 15 No. cells of 2 V each, sealed maintenance free VRLA type, high impact Polyprophelene copolymer container, flame retardant with stand 463 b) 30 V, 100 AH, float-cum-boost charger with full wave rectification for 220 V, 1 phase, 50 HZ AC input supply. 464 Distribution panel (30V, DC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 for two number battery incoming supplywith 2No. 63 Amp. DP MCB for incoming supplydouble bus bar of adequate size,twelve number DP DC MCB(0-32A) including indication lamp and cables and other accessories 465 Distribution panel (415 V, AC)made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 200A Switch fuse disconnector for incoming supply and five numbers TPN MCBs(16-125A) and five number DP MCB(0-32A),rectangular bus bar suitable for 200 A continous supply including indication lamp cables and other accessories. 466 Telecommunication facilities including cctvs set (4nos cameras ) LED Display (32) 467 CIVIL WORKS 468 Compound walling of identified land by way of Mass Concrete in Foundation and 228mm bricks of 2M height 469 Chain-link Fencing of 33kv Yard of Substation by way of Mass Concrete in Foundations and chain-link fencing of 6 ft height. 470 33/11kv power Transformer Foundation 471 33kv Equipment Foundation and gantry foundation 472 Earthing Mat complete job GI flat 50x8 mm 473 Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips 474 33kv Yard Concreting / Metalling 475 Underground Water tank 10000 Ltrs. 476 Overhead water tank 2000Ltr 477 Control room Building including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 478 Shift Quarters for Je and SBA including wash room ,pantry room .sanitary fittings tile works ,kota stone in control roominternal wiring,painting and fixing of electrical appliances like lights ,fans,geysers job complete finish 479 Truss for control room building 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing 158 sqm 480 Development of identified land by way of removing weeds, wild grass and undulation if any, ornamental land scraping and growing of ornamental trees in un built areas and road sides and development of road along with surface drain. 481 Construction of semi Pucca B/Wall of 2.0 Mtr. Height (Length=100 mtr) 482 Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone 483 Construction of Pucca Drain 484 Yard Lighting ( 6 Nos yard and 02 Nos CR back side) on 9m Long Poles 485 ERECTION OF 33 KV LINEDOOL(INCLUDING ALL FOUNDATION WORKS) 486 11 Mtr. Long ST Pole(For new line) ST-410 SP56 487 GI Channel X-arm including clamps and braces 488 100 mm² ACSR DogConductor 489 PG Clamps for 100 mm² ACSR Conductor 490 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 491 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings 492 Galvinized Nuts and Bolts. 493 Danger Plates with Clamps 494 Anti-Climbing Device with Clamps 495 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 496 Red Oxide 497 Aluminium Paint 498 Cement bottoming 1:2:4 mix as per REC standards .6cum /pole 499 Stone Pad (300 mm x 300 mmx 75 mm) 500 Aluminium Jointing Sleeves 501 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 502 Guard netting 503 SAFETY ITEMS FOR HASTI AND DOOL RECEIVING STRATIONS 504 Rubber Mat 1m*2m (19mm thick) 505 Fire Extinguisher CO2 type of 4.5 Kg capacity for control room 506 3-Sand Bucket Fire Extinguisher 507 Helmet 508 Rubber Gloves for 33 KV Level 509 Rubber Gloves for 11 KV Level 510 SafetyBelt 511 Safety Shoes 512 Earthing rod (set of 3 rods) 513 HV Detector all Voltages 514 Multimeter 515 C-SPARE ITEMS (TO BE SUPPLIED TO DIVISIONAL STORES ) 516 Aluminium Ladder Sliding type 30 feet Long 517 Lifting and Puling machine 5 Ton 518 Come along Ratchet Upto Wolf Conductor 519 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 520 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 521 Meggar 5KV (Reputed make ) 522 Digital earth tester as per relevant standards (Inspection shall be carried out by the representative of this Divisionbefore supplying )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
45.
Power #9334427 Technical Bid
Erection Of New 33 Kv Line -- 1 A-SUPPLY PART 2 NEW33 KV LINE 3 11 Mtr. Long ST Pole(For new line) ST-410 SP56 4 GI Channel X-arm including clamps and braces 5 150 mm² ACSR Conductor 6 PG Clamps for 200 mm² ACSR Conductor 7 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 8 33kV Polymeric composite Disc Insulator 36kV,min failing load 90kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings 4 bolts 9 Galvinized Nuts and Bolts. 10 Danger Plates with Clamps 11 Anti-Climbing Device with Clamps 12 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 13 Red Oxide 14 Aluminium Paint 15 Cement bottoming 1:2:4 mix as per REC standards .6cum /pole 16 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 17 Guard netting 18 33 KV Isolator Without Earthing Blade 19 SINGLE BUS OUT 20 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 21 33 KV Isolatorwith earthing blade (36 KV ,1250A.Outdoor.3 pole,25KA) 22 33 KV Isolatorwithout earthing blade (36 KV ,1250A.Outdoor.3 pole,25KA) 23 33 KV Current Transformer (Single Phase,Multi ratio,multi core ,Outdoor) 24 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 25 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 PHASE Trivector meter DLMS compliant RS 485 port 26 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 27 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 28 STEEL STRUCTURES 29 Pipe Nominal bore 200, 5.9 mm thick 30 Galvanised steel structures 31 Galvanized nuts and bolts 32 CONTROL CABLES 33 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 34 4 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 35 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 36 Lugs & Ferrules etc. 37 CONDUCTOR AND HARDWARE 38 200 sqmm ACSR Conductor Panther 39 T-Clamp 40 Single Tension Fitting 41 33 KV Disc insulator 42 Earth Wire 7/4.00 sqmm 43 G.I flat for earthing 50*6mm 44 SAFETY ITEMS (TO BE HANDED OVER AT DIVISIONAL STORES ) 45 Al.Ladder Extendable (30Long) 46 Lifting and Pulling machine 5Ton with Ratchet and Pulley for Panther 47 Helmet 48 Rubber Gloves for 33 KV Level 49 Rubber Gloves for 11 KV Level 50 SafetyBelt 51 Safety Shoes 52 Earthing rod (set of 3 rods) 53 HV Detector all Voltages 54 XLPE Cable stripping Tool 55 Tool boxes complete Comprising of D-ring spanners (6 to 32 No sizes),Hammer Wrench,Pliers 56 B-ERECTION PART 57 NEW 33 KV LINE 58 11 Mtr. Long ST Pole(For new line) ST-410 SP56 59 GI Channel X-arm including clamps and braces 60 150 mm² ACSR Conductor 61 PG Clamps for 200 mm² ACSR Conductor 62 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 63 33kV Polymeric composite Disc Insulator 36kV,min failing load 90kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings 4bolts 64 Galvinized Nuts and Bolts. 65 Danger Plates with Clamps 66 Anti-Climbing Device with Clamps 67 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 68 Red Oxide 69 Aluminium Paint 70 Cement bottoming 1:2:4 mix as per REC standards .6cum /pole 71 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 72 Guard netting 73 33 KV Isolator Without Earthing Blade 74 SINGLE BUS OUT 75 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 76 33 KV Isolatorwith earthing blade (36 KV ,1250A.Outdoor.3 pole,25KA) 77 33 KV Isolatorwithout earthing blade (36 KV ,1250A.Outdoor.3 pole,25KA) 78 33 KV Current Transformer (Single Phase,Multi ratio,multi core ,Outdoor) 79 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 80 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 PHASE Trivector meter DLMS compliant RS 485 port 81 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 82 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 83 STEEL STRUCTURES 84 Pipe Nominal bore 200, 5.9 mm thick 85 Galvanised steel structures 86 Galvanized nuts and bolts 87 CONTROL CABLES 88 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 89 4 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 90 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 91 Lugs & Ferrules etc. 92 CONDUCTOR AND HARDWARE 93 200 sqmm ACSR Conductor Panther 94 T-Clamp 95 Single Tension Fitting 96 33 KV Disc insulator 97 Earth Wire 7/4.00 sqmm 98 G.I flat for earthing 50*6mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
46.
Power #9322450 Technical Bid
Tender For Augmentation Of Receiving Station- A-SUPPLY PART 2 SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY 3 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 4 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 5 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 6 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 7 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 8 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 9 STEEL STRUCTURES 10 Pipe Nominal bore 200, 5.9 mm thick 11 Galvanised steel structures 12 Galvanized nuts and bolts 13 CONTROL CABLES 14 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 15 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 16 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 17 Lugs & Ferrules etc. 18 CONDUCTOR AND HARDWARE 19 ACSR Conductor Panther 20 T-Clamp 21 G.I Flat 50*6 mm 22 11KV (UE)XLPE Power Cables (Armoured) 23 11 kV630 mm² Single Core XLPE Cable (with one spare length) armoured, FRLS 24 11 kV (UE) 3-Core XLPE 185 mm² armoured, FRLS 25 11KVHeat shrink termination Cable Kits (Indoor) 630 mm square (1-core) 26 11KV Heat shrink termination Cable Kits (Outdoor) 630 mm square (1-core) 27 11KV Heat shrink termination Cable Kits (Indoor) 185 mm square(one spare) (3-core) 28 11KV Heat shrink terminationCable Kits (Outdoor) 185 mm square (one spare) (3-core) 29 COST FOR11 KV INDOORSWITCHGEAR OF 33/11 KV SUB-STATION 30 11 KV VCB Panel Board ( 12KV,1250A,25KA, Indoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector meter-5A,DLMS Compliant with RS-485 Port1 Incoming & 1 outgoings 31 CIVIL WORKS 32 33/11kv power Transformer Foundation 33 33kv Equipment Foundation and gantry foundation 34 Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips 35 Extension of Control room Building including with internal wiringand fixing of electrical appliances like lights ,fans,geysers job 36 Yard Lighting ( 2 Nos yard and 02 Nos CR back side) on 9m Long Poles 37 B- ERECTION PART 38 33/11 KV, 10 MVA Power Transformer (The power transformer shall be provided by the Electric Central Stores Division Jammu 39 Lifting of power transformer at Electric Central Stores Division Jammu ,Transportation, Erection testing and commissioning at Receiving Station Dandi,Bhaderwah (The ffirm will have to submit the insurance proof ofthe Transformer before despatching from the loading site) 40 SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY 41 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 42 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 43 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 44 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 45 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 46 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 47 STEEL STRUCTURES 48 Pipe Nominal bore 200, 5.9 mm thick 49 Galvanised steel structures 50 Galvanized nuts and bolts 51 CONTROL CABLES 52 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 53 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 54 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 55 Lugs & Ferrules etc. 56 CONDUCTOR AND HARDWARE 57 ACSR Conductor Panther 58 T-Clamp 59 G.I Flat 50*6 mm 60 11KV (UE)XLPE Power Cables (Armoured) 61 11 kV630 mm² Single Core XLPE Cable (with one spare length) armoured, FRLS 62 11 kV (UE) 3-Core XLPE 185 mm² armoured, FRLS 63 11KVHeat shrink termination Cable Kits (Indoor) 630 mm square (1-core) 64 11KV Heat shrink termination Cable Kits (Outdoor) 630 mm square (1-core) 65 11KV Heat shrink termination Cable Kits (Indoor) 185 mm square(one spare) (3-core) 66 11KV Heat shrink terminationCable Kits (Outdoor) 185 mm square (one spare) (3-core) 67 COST FOR11 KV INDOORSWITCHGEAR OF 33/11 KV SUB-STATION 68 11 KV VCB Panel Board ( 12KV,1250A,25KA, Indoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector meter-5A,DLMS Compliant with RS-485 Port1 Incoming & 1 outgoings 69 CIVIL WORKS 70 33/11kv power Transformer Foundation 71 33kv Equipment Foundation and gantry foundation 72 Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips 73 Extension of Control room Building including with internal wiringand fixing of electrical appliances like lights ,fans,geysers job 74 Yard Lighting ( 2 Nos yard and 02 Nos CR back side) on 9m Long Poles
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
47.
Power #9268698 Technical Bid
Tender For Restoration Of Receiving Station- 1 A-Supply Part 2 11 Kv Vcb Panel Board ( 1+4 ) ( 12 Kv, 1250A, 25 Ka, Outdoor ) With O / C , E / F Relays ( Iec61850 ) Mimic Digram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri Vector Meter-5Amps, Dlms Compliant With Rs485 Port 3 Distribution Panel ( 30 V, Dc ) Made Of Crca Thickness Not Less Than 2Mm. Powder Coated, Degree Of Protection Ip43 For 2 No Battery Incoming Supply With 2 No 63 Amps Dp Mcbs For Incoming Supply Doublebusbar Of Adequate Size, 12 No Dp Dc Mcb ( 0-32A ) Including Indication Lamps And Cables And Other Accessories 4 Distribution Panel ( 415 V, Ac ) Made Of Crca Thickness Not Less Than 2Mm. Powder Coated, Degree Of Protection Ip43. 200 Amps Switch Fuse Disconnector For Incoming Supply And 5 No Tpn McbS ( 16-125 Amps ) And 5 No Dp Mcbs ( 0-32A ) , Rectangular Busbar Suitable For 200 Amps Continuous Supply Including Indication Lamps And Cables And Other Accessories 5 A ) . Battery Bank 30 V, 100 Ah , Of 15 No. Cells Of 2 V Each, Sealed Maintenance Free Vrla Type, High Impact Polyprophelenecopolymer Container, Flame Retardant. B ) . 30V, 100 Ah , Float-Cum-Boost Charger With Full Wave Rectification For 220 V, 1Phase, 50 Hz Ac Input Supply . 6 Lt Distribution Box For 63 Kva Dtr With Mccb For Incomer & Outgoing Circuits Along With Lt Cts 7 12 Core 2.5 Mm² Control Cable Copper Armoured , 1.1 Kv Grade, Isi, Frls. 8 6 Core 2.5 Mm² Control Cable Copper Armoured , 1.1 Kv Grade, Isi, Frls. 9 2 Core 2.5 Mm² Control Cable Copper Armoured , 1.1 Kv Grade, Isi, Frls. 10 33 Kv Isolator With Earthing Blade ( 36Kv, 1250A, Outdoor, 3 Poles, 25 Ka ) 11 33 Kv Isolator Without Earthing Blade ( 36Kv, 1250A, Outdoor, 3 Poles, 25 Ka ) 12 Transformer Oil 13 Lugs, Ferrules Etc. 14 Acsr Dog Conductor 15 Led Yard Lightining 40 W ( With Brackets ) 16 95Mm²3½ Core Cable, 1.1Kv Grade, Armoured, Xlpe Insulated Stranded Conductor Frls Type 17 Filtration Of Transformer Oil 18 11 Kv Indoor Heat Shrinkable Cable Termination Kits 19 11 Kv Outdoor Heat Shrinkable Cable Termination Kits 20 B-Erection Part 21 11 Kv Vcb Panel Board ( 1+4 ) ( 12 Kv, 1250A, 25 Ka, Outdoor ) With O / C , E / F Relays ( Iec61850 ) Mimic Digram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri Vector Meter-5Amps, Dlms Compliant With Rs485 Port 22 Distribution Panel ( 30 V, Dc ) Made Of Crca Thickness Not Less Than 2Mm. Powder Coated, Degree Of Protection Ip43 For 2 No Battery Incoming Supply With 2 No 63 Amps Dp Mcbs For Incoming Supply Doublebusbar Of Adequate Size, 12 No Dp Dc Mcb ( 0-32A ) Including Indication Lamps And Cables And Other Accessories 23 Distribution Panel ( 415 V, Ac ) Made Of Crca Thickness Not Less Than 2Mm. Powder Coated, Degree Of Protection Ip43. 200 Amps Switch Fuse Disconnector For Incoming Supply And 5 No Tpn McbS ( 16-125 Amps ) And 5 No Dp Mcbs ( 0-32A ) , Rectangular Busbar Suitable For 200 Amps Continuous Supply Including Indication Lamps And Cables And Other Accessories 24 A ) . Battery Bank 30 V, 100 Ah , Of 15 No. Cells Of 2 V Each, Sealed Maintenance Free Vrla Type, High Impact Polyprophelenecopolymer Container, Flame Retardant. B ) . 30V, 100 Ah , Float-Cum-Boost Charger With Full Wave Rectification For 220 V, 1Phase, 50 Hz Ac Input Supply . 25 Lt Distribution Box For 63 Kva Dtr With Mccb For Incomer & Outgoing Circuits Along With Lt Cts 26 12 Core 2.5 Mm² Control Cable Copper Armoured , 1.1 Kv Grade, Isi, Frls. 27 6 Core 2.5 Mm² Control Cable Copper Armoured , 1.1 Kv Grade, Isi, Frls. 28 2 Core 2.5 Mm² Control Cable Copper Armoured , 1.1 Kv Grade, Isi, Frls. 29 33 Kv Isolator With Earthing Blade ( 36Kv, 1250A, Outdoor, 3 Poles, 25 Ka ) 30 33 Kv Isolator Without Earthing Blade ( 36Kv, 1250A, Outdoor, 3 Poles, 25 Ka ) 31 Transformer Oil 32 Lugs, Ferrules Etc. 33 Acsr Dog Conductor 34 Led Yard Lightining 40 W ( With Brackets ) 35 95Mm²3½ Core Cable, 1.1Kv Grade, Armoured, Xlpe Insulated Stranded Conductor Frls Type 36 Filtration Of Transformer Oil 37 11 Kv Indoor Heat Shrinkable Cable Termination Kits 38 11 Kv Outdoor Heat Shrinkable Cable Termination Kits
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
48.
Power #9247748 Technical Bid
Tender For Creation Of 33 / 11 Kv, 1X10 Mva Receiving Station Alongwith 33 Kv Line At Kaink Jagir In Respect Of Sub-Transmission Division-I, Jpdcl, Jammu For The Year2023-24- 1 11 Mtr. Long St Pole 2 9 Mtr. Long St Pole 3 Gi V Cross-Arm With Top Bracket Including Clamp 4 Gi Channel X-Arm Including Clamps And Braces 5 100 Mm² Acsr Conductor 6 Pg Clamps For 100 Mm² Acsr Conductor 7 33Kv Polymeric Composite Pin Insulator 36Kv, 10Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm 8 33Kv Polymeric Composite Disc Insulator 36Kv, Min Failing Load 70Kn, Lighting Impulse 170Kv Positive And 180Kv Negative, Creepage Distance 900Mm 9 Danger Plates With Clamps 10 Anti-Climbing Device With Clamps 11 Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip. 12 Red Oxide 13 Aluminum Paint 14 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5 Cum / Pole 15 Aluminum Jointing Sleeves 16 33Kv Isolator With Earthing Blade ( 36Kv, 1250A, Outdoor, 3 Poles, 25 Ka ) 17 Galvanised Stay Set With 50 X 8 Mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 300X 300 X 8 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 20 Mm Diameter Solid Gs Stay Rod & 7 / 4.00 Mm Dia Gi Stranded Wire Complete 18 Guard Netting 19 33 Kv Vcb ( 36 Kv, 1250A, 26.2 Ka, Outdoor Type ) 20 33Kv C&R Panel Along With O / C, E / F Relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3- Phase Tri Vector Meter 5 Amps With Rs-485 Port Dlms Compliant With Rs-485 Port 21 33Kv Isolator With Earthing Blade ( 36Kv, 1250A, Outdoor, 3 Poles, 25 Ka ) 22 33Kv Isolator Without Earthing Blade ( 36Kv, 1250A, Outdoor, 3 Poles, 25 Ka ) 23 33Kv Current Transformer ( 33Kv, 1Ø, Multi Ratio-Multi Core , Outdoor ) ( 1 No. Per Ø ) Of Ratio 600 / 300 / 5 Amp 24 33Kv Voltage Transformer ( 33Kv / 110V, 1Ø, Multi -Core , Outdoor ) ( 1 No. Per Ø ) 25 30Kv Lightening Arrestors ( 30Kv, 10Ka, Station Class Zno, Polymer ) Gap Less 26 Galvanised Steel Structures 27 Galvanised Nuts & Bolts 28 12 Core 2.5Mm2 Control Cable Copper Armoured, 1.1 Kv Grade , Isi, Frls 29 4 Core 2.5Mm2 Control Cable Copper Armoured , 1.1 Kv Grade , Isi, Frls 30 2 Core 2.5Mm2 Control Cable Copper Armoured , 1.1 Kv Grade , Isi, Frls 31 Lugs, Ferrules Etc 32 Acsr Conductor Panther 33 T Clamps 34 Single Tension Fittings 35 Earth Wire 7 / 4.00 Mmsq. 36 Gi Flat For Earthing 50X6 Mm For All Equipments & Gantries 37 33 Kv C& R Panel Along With O / C, E / F And Differential Relays ( Iec61850 ) , Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3 Phase Trivector Meter 5 Amps, Dlms Compliant With Rs 485 Port 38 33Kv Post Insulator Polymer 36Kv, 235Kv Impulse , Creepage Distance 1224M 39 33 / 11 Kv, 10 Mva, Onan, Copper Wound, Out Door Type Conventional Power Transformer , Oil Filled With Oltc And All Accessories Including Ht And Lt Terminal Connections 40 6 Core 2.5 Mm2 Control Cable Copper Armoured 1.1 Kv Grade, Isi, Frls 41 11Kv Vcb Panel Board ( 12Kv, 1250A, 25Ka, Outdoor ) With O / C, E / F Relays ( Iec61850 ) , Mimic Diagram, Voltmeter, Ammeter, Annunciation Relays, 3-Phase Tri Vector Meter-5 Amps, Dlms Compliant With Rs-485 Port For 1X10 Mva ( 1+5 ) Scada Compatible 42 11Kv Gapless Surge Arrestor, 9Kv, 10Ka, La With Polymer Housing Stn. Type 43 11Kv, 630Mm2, Single Core Xlpe Cable ( With One Spare Length ) Armoured, Frls 44 11Kv, 3-Core, 240Mm2 Xlpe Cablearmoured, Frls 45 11Kv Indoor Heat Shrinkable Cable Termination Kits For Incoming Cable, 630Mm2 Single Core 46 11 Kv Outdoorheat Shrinkable Cable Termination Kits For Incoming Cable 630Mm2 Single Core 47 11Kv Indoor Heat Shrinkable Cable Termination Kits For Outgoing Cable 240 Mm2 Single Core 48 11 Kv Outdoorheat Shrinkable Cable Termination Kits For Outgoing Cable 240 Mm2 Single Core 49 11Kv Isolator, Double Break, 3- Pole, 600Amp, Horizontal Mounting Type, With Earth Switch 50 Galvanised Iron Of Sorts 51 100 Kva, 11 / 0.43Kv, 3 Phase Distribution Transformers With Bimetallic Terminal Connectors Energy Level-2 ( Aluminum Wound ) 52 120Mm2 Pvc Lt Cable 3.5 Core, Armoured, Frls 53 Earthing Of 100Kva Substation ( Chemical Earthing ) 54 Earthingcomplete By Gi Pipe 40 Mm 55 Mccb -200Amps With Enclosure 56 12 Kv Capacitor Bank ( 3.6 Mvar ) With Vcb Panel With Complete Arrangement For Connection With 11Kv Incomer Panel, Series Reactor Isolator, Rrvt, Surge Arrestors Ht Cable With Termination Kits, Control Cables, Crca Cubicle Panel Etc With Structure, Foundation & Accessories 57 Compound Walling Of Identified Land By Way Of Mass Concrete In Foundations And 228Mm Brick Wall Of 2 M Height Including Excavation And Disposal Of Unwanted Soil Alongwith 5 Mtr Long, 2 Mtr Height Gate And 2 Nos. Rcc Pillars Fitted With Light Complete In All Respect 58 Chain Link Fencing Of 33Kv Yard Of Substation By Way Of Mass Concrete Of 33Kv Yard Of Sub Station By Way Of Mass Concrete In Foundations And Chain Link Fencing Of 6 Ft Height 59 Rcc Cable Trench ( 1:2:4 ) For Laying Of 11 Kv Xlpe Power Cable And Control Cable From Power Transformer, Vcb And Other Equipments To Control Room And For Outgoing Cables From Control Room To Outgoing Structures Including Gi Perforated Trays And Cable Duct Covers ( Cable Duct Covers Should Be Framed Using Angle 50X50x6 Mm And 10 Mm Tar Steel Including Excavation And Disposal Of Un-Wantedsoil. 60 33 / 11 Kv Power Transformer Foundation 61 33 Kv Equipment Foundation & Gantry Foundation 62 Earthing Mat ( Gi Flat 75 Mmx8mm ) And Filling Of Good Earth 63 Gi Earthing Electrode ( 3M Long 32Mm Dia ) Through Gi Strip 64 33 Kv Yard Concreting With 2 Gravel Of 20 Mm On Top, 3 Concrete In The Ratio Of 1:2:4 Mix ( M-15 ) Beneath And 3 Gravel Of 40 Mm Beneath The Concrete Layer 65 Bore Well With Submersible Pump 66 Design, Engineering And Construction Of Air Conditioned Control Room Building ( 4 Nos Acs Of 2 Ton Capacity ) Consisting Of Rcc Slab Including Trenches, Comprising Of Battery Room, Panel Room, Toilet Complete In All Respect With Aluminum Doors And Windows, Stair Case, Underground Sewage Tank, Under Ground Water Tank, Overhead Watertank, Motor Pump For Water Lifting As Required Of Overall Building Or As Per Electrical Requirement ( Single Storey Including All Internal Services Like Water Supply Including Supply And Fixingof Pipes, Water Taps Etc., Electric Fitting Including Wiring Withfans, Lights & Switches, Sewerage System, Finishing Plinth Protection Including Supply Of Construction Material, Labour, Cement, Reinforcement Steel, Frame Work Etc Complete In All Respect 67 Design, Engineering And Construction Ofshift Quarters For Je And Sba Building Consisting Of Rcc Slab, Bathroom, Complete In All Respect With Aluminum Doors And Windows, Stair Case, Underground Sewage Tank, Overhead Watertank, Motor Pump For Water Lifting As Required Of Overall Building Or As Per Electrical Requirement ( Single Storey Including All Internal Services Like Water Supply Including Supply And Fixingof Pipes, Water Taps Etc., Electric Fitting Including Wiring Withfans, Lights & Switches, Sewerage System, Finishing Plinth Protection Including Supply Of Construction Material, Labour, Cement, Reinforcement Steel, Frame Work Etc Complete In All Respect 68 Development Of Land By Removing Weeds, Wild Grass And Endulation If Any, Ornamental Land Scaping And Growing Of Ornamental Trees In Unbuilt Areas And Road Sides And Development Of Roads Along With Surface Drains Alongwith Concreting Of Area From Gate To Yard And Control Room, Complete In All Respect 69 Yard Lightening With 9 Mtr 4 Nos. High Mask Fitted With 4 Nos. 100 Watt Led Light On Each Pole Complete With Bracket Clamp & Earthing And Service Cable Alongwith Control Board. 70 A ) Battery Bank 30 V, 100Ah, Of 150 No. Cells Of 2 V Each, Sealed Maintenance Free Vrla Type, High Impact Polyprophelene Copolymer Container, Flame Retardant.B ) 30V, 100Ah, Float-Cum- Boost Charger With Full Wave Rectification For 220V, 1 Phase , 50 Hz Ac Input Supply. 71 Distribution Panel ( 30 V, Dc ) Made Of Crca Thickness Not Less Than 2Mm. Power Coated, Degree Of Protection Ip43 For 2 No Battery Incoming Supply With 2 No 63 Amps Dp Mcbs For Incoming Supply Double Bus Bar Of Adequate Size , 12 No. Dp Dc Mcb ( 0-32A ) Including Indication Lamps And Cables And Other Accessories 72 Distribution Panel ( 415 V, Dc ) Made Of Crca Thickness Not Less Than 2Mm. Power Coated, Degree Of Protection Ip43.200 Amps Switch Fuse Disconnect Or For Incoming Supply And 5 No Tpn McbS ( 16-125 Amps ) And 5 No Dp McbS ( 0-32A ) , Rectangular Busbar Suitable For 200Amps Continuous Supply Including Indication Lamps And Cables And Other Accessories 73 Telecommunication Facilities & Wifi Facilities 74 Rubber Mat 1Mx2m 19Mm Thick 75 Fire Extinguisher Co2 Type Of 4.5 Kg Capacity For Control Room 76 3 Sand Bucket Fire Extinguisher 77 Helmet 78 Rubber Gloves For 33Kv Level 79 Rubber Gloves For 11Kv Level 80 Safety Belt 81 Safety Shoes 82 Earthing Rod ( Set Of 3 Rods ) 83 Hv Detectors All Voltages 84 Separate Earthings Of Equipments Through G.I. Strip 25X3 Mm. 85 Servo Transformer 11 / 0.433Kv 100 Kva 86 Part-Sparestransformer Oil 87 Outdoor Ct 600 / 300 / 5 Amp 88 Ht & Lt Bushing Of Transformer Each 89 11 Kv Vcb Trolley With Vacuum Interrupter Complete 90 Digital Earth Clamp Tester 91 Tool Kit Complete Including Different Types Of Spanners, Drill Machine, Wrenches, Plier And All Other Allied Material 92 Office Table With Chair ( 1+5 ) 93 Branded Steel Almirah Full Size 94 10 Kv Digital I R Tester Megger / Motwane / Any Other Reputed Make Approved By Cea / Pgcil
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
49.
Heavy Industries and Public Enterprises #9244911 Technical Bid
Supply Of E4833052 Pcb - 36 Items Rate Contract E4833052 Pcb -36 Items Rate Contract , Pcb ( 36 Items ) , Pcb-Generator Exciter For Generator Control Panel Asper Item No. 001 Of Bhel Specification No. Or12942, Rev. 02. Asper Hillgraham Part No. P359t Or Nov ( Rosshill ) Part No0509-7901-00. Pcb To Be Suitable For Exciter Transformer O / P Voltage 240Vac. , Pcb-Capacitor Diode For Generator Panel As Per Item No. 015 Of Bhel Specification No. Or12942, Rev. 02 , Pcb-Diode For Generator And Scr Panel As Per Item No. 009 Of Bhel Specification No. Or12942, Rev. 02. , Pcb-Scr Auxiliary For Scr Panel As Per Item No. 008 Of Bhel Specification No. Or12942, Rev. 02. As Per Hillgraham Part No P396t. , Pcb-Voltage Feedback For Scr Panel As Per Item No. 004 Of Bhel Specification No. Or12942, Rev. 02. As Per Hillgraham Part No. P363t. Nov ( Rosshill Part No. 0509-3000-00. Pcb To Be Calibrated For 750:46.8Vdc. , Pcb-Contactor Auctioneering For Scr Panel As Per Item No. 011 Of Bhel Specification No. Or12942, Rev. 02. As Per Hillgraham Part No. P362t , Solid State Relay Pcb To Bhel Spec. No. 12952, Rev.01, It.002 , Pcb-Power Limit For Feeder Panel As Peritem No. 012 Of Bhel Specification No. Or12942, Rev. 02. As Per Hillgraham Part No. P383t. Pcb To Be Calibrated For Kw Limit 850 Kw And Itotal Limit 1250A.A Sticker To Be Pasted On Back Of Pcb With Calibration Details , Pcb-Battery Charger For Feeder Panel As Per Item No. 005 Of Bhel Specification No. Or12942, Rev. 02. As Per Hillgraham Part No. P378t. , Pcb-Sync Check And Battery Charger For Feeder Panel As Per Item No. 003 Of Bhel Specification No. Or12942, Rev. 02 As Per Hillgraham Part No. P425m , Pcb-Field Supply Regulator For Active Field Supply As Per Item No. 002 Of Bhel Specification No. Or12942, Rev. 02.As Per Hillgraham Part No P355m. , Driller Console Pcb To Bhel Spec. No. Or12952, Rev.01, It.001 , Plc Auctioneering Pcb To Bhel Spec. No. Or12952, Rev.01, It.003 , Pcb-Mdc-M As Per Item No-1 Of Of Bhel Specification Or 12937 Rev.03 Fully Assemble & Tested. , Pcb-Mac-A As Per Item No-4 Of Bhel Specification Or 12937Rev.03 Fully Assemble & Tested , Pcb-Mdc-A As Per Item No.02 Of Bhel Specification No.Or12937, Rev.03 , Pcb-Mac-M As Per Item No-3 Of Bhel Specification Or 12937Rev.03 Fully Assemble & Tested , Logic Indicator Pcb Along With Facia Plate For Scr1 E760 Rig As Per Item No. 001 Of Spec. Or 12943, Rev.01. , Logic Indicator Pcb Along With Facia Plate For Scr 2 For E760 Rig As Per Item No. 002 Of Spec. Or 12943, Rev.01. , Logic Indicator Pcb Along With Facia Plate For Scr 3 For E760 Rig As Per Item No. 003N Of Spec. Or 12943, Rev.01 , Logic Indicator Assembly For Scr4 For E760 Rig As Per Item No. 004 Of Spec. Or 12943, Rev.01. , Logic Indicator Assembly ( Mimic Pcb & Facia Plate ) For Scr-1 Panel E1400 Rigs As Per Bhel Spec Or12943 R01 It 005. Facia Plate Shall Be Of Good Quality And Aesthetics. Ref Notes In Drawing For The Quality Requirement Of Facia Plates. , Logic Indicator Assembly ( Mimic Pcb & Facia Plate ) For Scr-2 Panel E1400 Rigs As Per Bhel Spec Or12943 R01 It 006. Facia Plate Shall Be Of Good Quality And Aesthetics. Ref Notes In Drawing For The Quality Requirement Of Facia Plates. , Logic Indicator Assembly ( Mimic Pcb & Facia Plate ) For Scr-3 Panel E1400 Rigs As Per Bhel Spec Or12943 R01 It 007. Facia Plate Shall Be Of Good Quality And Aesthetics. Ref Notes In Drawing For The Quality Requirement Of Facia Plates. , Logic Indicator Assembly ( Mimic Pcb & Facia Plate ) For Scr-4 Panel E1400 Rigs As Per Bhel Spec Or12943 R01 It 008. Facia Plate Shall Be Of Good Quality And Aesthetics . Ref Notes In Drawing For The Quality Requirement Of Facia Plates. , Pcb-Driller Console As Per Item No. 014 Of Bhel Specification No. Or12942, Rev. 02. , Pcb-Amplifier & Ref ( Multiple Input ) As Per Item No. 007 Of Bhel Specification No. Or12942, Rev. 02. As Per Hillgraham Part No P414t. , Pcb-Signal Switching For Scr Panel As Per Item No. 010 Of Bhel Specification No. Or12942, Rev. 02 , Pcb-Low Pass Filter For Frequeny Meter As Per Item No 016 Of Spec Or12942 Rev02 , Pcb-Ground Fault For Ac / Dc Groundf Fault Meters And Indication For Feeder Panel As Per Item No. 013 Of Bhel Specification No. Or12942, Rev. 02. , Logic Indicator Assembly ( Mimic Pcb & Facia Plate ) For Scr-1 Panel E3000-1. Rigs As Per Bhel Spec Or12956 R00 It 001. Facia Plate Shall Be Of Good Quality And Aesthetics. Ref Notes In Drawing For The Quality Requirement Of Facia Plates. , Logic Indicator Assembly ( Mimic Pcb & Facia Plate ) For Scr-2 Panel E3000-1. Rigs As Per Bhel Spec Or12956 R00 It 002. Facia Plate Shall Be Of Good Quality And Aesthetics. Ref Notes In Drawing For The Quality Requirement Of Facia Plates. , Logic Indicator Assembly ( Mimic Pcb & Facia Plate ) For Scr-3 Panel E3000-1. Rigs As Per Bhel Spec Or12956 R00 It 003. Facia Plate Shall Be Of Good Quality And Aesthetics. Ref Notes In Drawing For The Quality Requirement Of Facia Plates. , Logic Indicator Assembly ( Mimic Pcb & Facia Plate ) For Scr-4 Panel E3000-1. Rigs As Per Bhel Spec Or12956 R00 It 004. Facia Plate Shall Be Of Good Quality And Aesthetics. Ref Notes In Drawing For The Quality Requirement Of Facia Plates. , Logic Indicator Assembly ( Mimic Pcb & Facia Plate ) For Scr-5 Panel E3000-1. Rigs As Per Bhel Spec Or12956 R00 It 005. Facia Plate Shall Be Of Good Quality And Aesthetics. Ref Notes In Drawing For The Quality Requirement Of Facia Plates. , Logic Indicator Assembly ( Mimic Pcb & Facia Plate ) For Scr-6 Panel E3000-1. Rigs As Per Bhel Spec Or12956 R00 It 006. Facia Plate Shall Be Of Good Quality And Aesthetics. Ref Notes In Drawing For The Quality Requirement Of Facia Plates.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Madhya Pradesh View Result →
50.
Power #9242678 Technical Bid
Supply Of Miscellaneous Electrical Items For Btps, Obra , Flanged End Gas Valve Suitable For Hydrogen Gas(Bellow Sealed).The H2 Pressure Of System Is 3-3.5 Kg/Cm2 (Suitable For 6 Kg/Cm2 H2 Gas Pressure ). Material Ofvalve (Brass/Al.Alloy) (Fig.9) (As Per Sample , Lighting Panel 415 V Industrial 60 Amp 3 Pole L.P.A. (12) , Ictp Switches, 63A , Ictp Switches, 200A , 100 Amp Terminal Block , Flush Type Switch Board 8X4 With Swich And Socket 15 A , Board 8X10 With Swich And Socket 5 A , Mcb 1 Pole 20 Amp , Mcb 4 Pole 60 Amp , 1Cx2.5 Mm2 1.1Kv Grade Single Core Cu Conductor Pvc Insulated Wire , 1Cx4mm2 1.1 Kv Grade Single Core Cu Conductor Pvc Insulated Wire , 1X20 W, Led Tube Rod T8, Vase G-13, Retrofit, Efficiency: 100Lm/W , Indication Lamp Led (For Mimic Panel Of Chp Control Room And 1 Other Area Of Emd(Coal)) Specification=110V Ac, 3 W Cap=E-10 , Indication Lamp Led Specification=220V Ac, 3 W Dia 20-24Mm , Indication Lamp Led Specification=220V Dc, 3 W Dia-20-24Mm , Mccb 3 Pole 3 Phase 250Amp , Control Fuse 6Amp , Ohrc Power Fuse 315 Amp , Ohrc Power Fuse 200 Amp , Ohrc Power Fuse 250 Amp , Ohrc Power Fuse 63 Amp , Ohrc Power Fuse 25 Amp , Push Button With Two On , Push Button With Two Off , 63A,415V, Tpn Main Switch , 100A,415V, Tpn Main Switch , 32A,220V Dp Main Switch , 100A,415V, Tpn Changeover Switch , Mcb, 1P,20A , Terminal Block Pvc/Backlelite 35Mm2 , Fr Wire 1.5Mm2, Pvc Included Multi Standed , Condenser 2.5 Uf , Condenser 3.15 Uf , Ceiling Fan, 1200Mm Sweep 220V , Ignitor For 70-400W Hpsv Lamp , 300X50x2mm Size Ladder Type Gu Cable Tray (Ltct-300Var-A) , Heavy Duty Pull Chord Switch, Type- Roe/Ii Contact 2No+2Nc, 16 Amp, 500V, 50 Hz, Enclosure: Die Costing Aluminium (Lm-6) Protection Class: Ip-65 (As Per Is-2147), Gasket: Nitrile Rubber Gasket, Reset: Manual Rest Type , 2 Core 6 Mm2 Pvc Unarmoured Aluminium Cable , 2 Core 10 Mm2 Pvc Unarmoured Aluminium Cable , 3 Core 16 Mm2 Pvc Unarmoured Aluminium Cable , Aluminium Lug 150 Mm2 , Aluminium Lug 185 Mm2 , Aluminium Lug 300 Mm2 , Aluminium Lug 400 Mm2 , Aluminium Lug 500 Mm2 , Electronic Choke 40 W , Pvc Tape , 40 Amp 2 Pole Isolator (Mcb) 220 V , Switch 05 Amp , Socket 05 Amp , Switch 15 Amp , Socket 15 Amp , Bakelite Base 3 Pin Plug Top 05 Amp , Bakelite Base 3 Pin Plug Top 15 Amp , Bell Ding Dong Type , Bell Switch 05 Amp , Mcb Box With 3 Pin Socket 32 Amp , 2Cx6sq Mm Aluminium Cable , 3Cx240sq Mm Pvc Aluminium Cable Conductor (Lt) , 3Cx400sq Mm Pvc Aluminium Cable Conductor (Lt)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
TenderDetail
Loading tenders