BRR : 10529850
Click Here To View Tendering Authority. Price Bid City/State :  NDMC Buildings, Delhi
Tender Brief : Comprehensive annual maintenance contract for Fire Alarm and Detection System at various at Palika Parking, Mohan Singh Place, Shaheed Bhagat Singh Place and Palika Place in NDMC area . , comprehensive amc for fire alarm and detection systems installed at below cited buildings including weekly/fortnightly/monthly visits and whenever required or in case of any defect in the system by the team consisting of engineer , technicians and helpers with the aim to keep the system functional round the clock including servicing , maintenance , testing and cleaning the system internally as well as extern... Read More
Tender Value
4,73,904
Submission Date
30-09-2020
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 4,66,511.1 L2
2 cnet-technologies Bid Analytics 4,50,208.8 L1
Work Detail
comprehensive annual maintenance contract for fire alarm and detection system at various at palika parking, mohan singh place, shaheed bhagat singh place and palika place in ndmc area . , comprehensive amc for fire alarm and detection systems installed at below cited buildings including weekly/fortnightly/monthly visits and whenever required or in case of any defect in the system by the team consisting of engineer , technicians and helpers with the aim to keep the system functional round the clock including servicing , maintenance , testing and cleaning the system internally as well as externally . the inventory installed in the building for servicing , maintenance , testing & keeping the system in perfect order is available at the respective control rooms complete to the entire satisfaction of fire officer/engineer in charge . i ) palika parking ii ) mohan singh place iii ) shaheed bhagat singh place iv ) palika place a ) engineer - 1 no . - 01 visit / week b ) technical foreman - 01 no . - 01 visit / week c ) helper - 02 nos . - 01 visit ( each ) / week note : atleast 01 visit/week/building is required by the team consisting of 01 engineer , 01 technician and 02 helpers , engineer , technician , helper , replacement/supply , installaton , testing/ commissioning of smoke detector with builtin led and mounting base complete with all connections etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , replacement/supply , installaton , testing/ commissioning of heat detector operating at 54/57 degree celsius with rate of rise cum fixed temperature ( dual thermistor ) type with mounting base complete with all connections etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , replacement/supply , installaton , testing/ commissioningof manual call boxes of ms construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , replacement/supply , installaton , testing/ commissioning of response indicator on surface / recess ms box having two leds metallic cover complete with all connections etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , replacement/supply , installaton , testing/ commissioning of fire alarm sounder with facility to make announcement , mounted in ms box ( 16swg ) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , replacement/supply , installaton , testing/ commissioning of of fire alarm sounder with facility to make announcement , mounted in abs box ( 16swg ) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , replacement/supply , installaton , testing/ commissioning of of sector panel suitable for following zones , complete with visual indications for short circuit fault , open circuit fault , fire condition and all other standard facilities as per is:2189 with mimic diagram for all area/zone covered , complete with all connections , interconnections etc . complete in all respect to the entire satisfaction of fire officer/engineer in-charge , 4 zone , 6 zone , supplying and laying of 2 x 1 . 5 sq . mm fire alarm armoured cable , 600/1000v rated with annealed copper conductor having xlpe insulation , steel wire armouring & frls outer sheath complete in all respect to the entire satisfaction of fire officer / engr-in-charge . , credit of unserviceable materials including dismantling the same and removal from the site/ disposing off as per norms and specifications complete all as specified and as directed by fire officer/engr-in-charge . , smoke/heat detectors obtained from item no . 02 & 03 , ms manual call boxes obtained from item no . 04 , response indicators obtained from item no . 05 , fire alarm sounder obtained from item no . 06 & 07 , fire alarm panels obtained from item no . 08
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download a16a41da-e4ee-4433-b4cb-7320f4d7d117 financialevaluation notice
Download boqcomparativechart boq document
Download finsummary_246166 aoc document
Download File Name File Description
Download F1C561B7-0C4F-426B-8BF6-949A760B3D7E Tender Documents - Tender Notice
Download Tendernotice_1 Tender Documents - NIT Documents
Download BOQ_246166 Tender Documents - BOQ
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Financial Evaluation In Progress

Financial bids are currently under review. Awarded bidder information will be published after final evaluation.

PriceBid
Similar Tenders Results
TenderDetail
Loading tenders