BRR : 10618443
Tender Brief : Annual Repair And Maintenance Of Fire Alarm , Detection And Pa Cum Talk Back System At Various Ndmc Buildings During 2020-21 . Sub Head- Comprehensive Amc For Fire Alarm And Detection System At Lok Nayak Bhawan And Palika Bhawan , Comprehensive Amc For Fire Alarm And Detection Systems Installed At Below Cited Buildings Including Weekly / Fortnightly / Monthly Visits And Whenever Required Or In Case Of Any Defect In The System By The Team Consisting Of Engineer , Technicians And Helpers With The Aim To Keep The System Functional Round The Clock Including Servicing , Maintenance , T... Read More
Tender Value
₹
Ref. Document
Submission Date
15-01-2021
Participated Bidder List
3 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 4,96,628.74 | L1 | |||
| 2 | cnet-technologies | Bid Analytics | |||||
| 3 | cnet-technologies | Bid Analytics | 5,02,795.1 | L2 |
Work Detail
annual repair and maintenance of fire alarm , detection and pa cum talk back system at various ndmc buildings during 2020-21 . sub head- comprehensive amc for fire alarm and detection system at lok nayak bhawan and palika bhawan , comprehensive amc for fire alarm and detection systems installed at below cited buildings including weekly / fortnightly / monthly visits and whenever required or in case of any defect in the system by the team consisting of engineer , technicians and helpers with the aim to keep the system functional round the clock including servicing , maintenance , testing and cleaning the system internally as well as externally . the inventory installed in the building for servicing , maintenance , testing & keeping the system in perfect order is available at the respective control rooms complete to the entire satisfaction of fire officer / engineer in charge . lok nayak bhawan and palika bhawan a ) engineer - 1 no . - 01 visit / fortnight b ) technical foreman - 01 no . - 01 visit / week c ) helper - 02 nos . - 01 visit ( each ) / week , engineer , technician , helper , replacement / supply , installaton , testing / commissioning of smoke detector with builtin led and mounting base complete with all connections etc . complete in all respect to the entire satisfaction of fire officer / engineer in-charge , replacement / supply , installaton , testing / commissioningof manual call boxes of ms construction in surface / recess with stainless steel chain & hammer assembly complete with glass and push button etc . complete in all respect to the entire satisfaction of fire officer / engineer in-charge , replacement / supply , installaton , testing / commissioning of fire alarm sounder with facility to make announcement , mounted in ms box ( 16swg ) with hinged cover plate & suitable for operation with amplifier i / c line matching transformer etc . complete in all respect to the entire satisfaction of fire officer / engineer in-charge , replacement / supply , installaton , testing / commissioning of of sector panel suitable for following zones , complete with visual indications for short circuit fault , open circuit fault , fire condition and all other standard facilities as per is:2189 with mimic diagram for all area / zone covered , complete with all connections , interconnections etc . complete in all respect to the entire satisfaction of fire officer / engineer in-charge , 4 zone , 6 zone , supplying and laying of 2 x 1 . 5 sq . mm fire alarm armoured cable , 600 / 1000v rated with annealed copper conductor having xlpe insulation , steel wire armouring & frls outer sheath complete in all respect to the entire satisfaction of fire officer / engr-in-charge . , credit of unserviceable materials including dismantling the same and removal from the site / disposing off as per norms and specifications complete all as specified and as directed by fire officer / engr-in-charge . , smoke detectors obtained from item no . 02 , ms manual call boxes obtained from item no . 03 , fire alarm sounder obtained from item no . 04 , fire alarm panels obtained from item no . 05
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Financial Evaluation In Progress
Financial bids are currently under review. Awarded bidder information will be published after final evaluation.