| 1 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | Demolishing R.C.C. work manually/by mechanical means includingstacking of steel bars and disposal of unserviceable material within 50meters lead as per direction of Engineer-in-charge. |
| 3 | Demolishing brick work manually/by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 meters lead as per direction of Engineer-in-charge: In mud mortar |
| 4 | Removing mortar from bricks and cleaning bricks including stackingwithin a lead of 50 m. (stacks of cleaned bricks shall be measured) : From brick work in mud mortar |
| 5 | Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 meters lead : Of area of 3 sqm. and below |
| 6 | Demolishing mud phaska in terracing and disposal of material within 50meters lead |
| 7 | Dismantling roofing including ridges, hips valleys and gutters etc., andstacking the material within 50 meters lead of : G.S. Sheet |
| 8 | Dismantling steel work in built up sections in angles, tees, flats andchannels including all gusset plates, bolts, nuts, cutting rivets, welding etc.including dismembering and stacking within 50 meters lead. |
| 9 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) using bricks obtained from dismantling. Bricks available at site |
| 10 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres in All kinds of soil |
| 11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 12 | Providing and laying 75mm thick compacted bed of dry brick aggregate 40mm thick nominal size including spreading, well rammed, consolidated and grouted with fine sand including finishing smooth etc. complete as per direction of Engineer-in-charge |
| 13 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 14 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 15 | Supplying and laying including digging, carrying by lorry, filling River Bed Material including watering & consolidation in layers to specified lines, camber, grades and cross sections. Finished work including material , labour all leads , lifts and carriage of material by MT/HL. |
| 16 | Providing and laying in position specified grade of reinforced cement concrete inclu. curing but excluding the cost of centering, shuttering, finishing & reinforcement. All works upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone agg. 20 mm nominal size) |
| 17 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 18 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 19 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 20 | Centring and shuttering including strutting propping etc and removal of form work |
| 21 | Foundations, footings, bases of columns etc. for mass concrete |
| 22 | Suspended floors, roofs, landing, balconies and access platforms. |
| 23 | columns, Pillars,Piers, Abutments, Posts and Struts. |
| 24 | Stairs (excluding landings) except spiral staircases. |
| 25 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 26 | Edge of slabs and break in floors and walls Under 20 cms wide. |
| 27 | Weather shade, chajjas, corcels etc., including edes. |
| 28 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 29 | Providing and laying dry stone agg. Using 40mm nominal size incl. spreading,levelling sand grouting, watering, ramming, etc all complete |
| 30 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete. |
| 31 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth including all shapes, leads, lifts and carriage of material by MT / H.L. in cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 32 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. |
| 33 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 34 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 35 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand). |
| 36 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 coarse sand) |
| 37 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 38 | Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete. |
| 39 | Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length and jointedtogether at the end by end locks, mounted on specially designed pipe shaftwith brackets, side guides and arrangements for inside and outside lockingwith push and pull operation complete, including the cost of providing andfixing necessary 27.5 cm long wire springs manufactured from high tensilesteel wire of adequate strength confirming to IS:4454 part-1 and M.S. topcover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 40 | Extra for providing mechanical device chain crank operation for operatingrolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area |
| 41 | Providing wood work in frames of doors, windows, clerestory windows andother frames, wrought framed and fixed in position with hold fast lugs or withdash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Second class deodar wood |
| 42 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1stclass hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 43 | Providing and fixing 35mm thick glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. in Second Class Deodar Wood |
| 44 | Providing and fixing 35mm thick wire guage shutters using galvanised M.S. wire guage of average width for aperture 1.4 mm in both direction with wire of dia 0.63 mm for doors, windows and clerestory windows with ISI marked M.S pressed but hinges bright finished butt hinges of required size with necessary screws, in Second Class Deodar Wood |
| 45 | Providing 40x5 mm flat iron hold fast 40 em long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size ) |
| 46 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. |
| 47 | P/Fixing of 4mm thick ACP sheets for door panells including cost of screws ets complete. |
| 48 | Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete : 100x10 mm |
| 49 | 100x10 mm |
| 50 | 200x10 mm |
| 51 | 250x10 mm |
| 52 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 53 | 125 mm |
| 54 | 100 mm |
| 55 | Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete : |
| 56 | Providing and fixing aluminum hanging floor door stopper, ISI marked,anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparentor dyed to required colour or shade with necessary screws etc. complete : Twin rubber stopper |
| 57 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm |
| 58 | Providing and fixing ISI marked aluminum butt hinges ISI marked anodized(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x75x4 mm |
| 59 | Finishing walls with acrylic smooth exterior paint of required shade onNew work (Two or more coats applied @ 1.67 liter/10sqm over andincluding priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 60 | Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade on New work (two or more coats) overand including priming coat with water thinnable cement primer |
| 61 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work ( wood work). |
| 62 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood). |
| 63 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing, making of edge moulding & nosing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 64 | Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08%and conforming to IS:15622 of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigmentsetc. complete Size of tile 600x600 mm |
| 65 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 66 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 67 | Providing and fixing 18mm gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels (Area of slab upto 0.5 sqm) |
| 68 | Extra for providing edge moulding to 18 mm thick Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 69 | Providing and fixing on wall face unplasticized - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.110 mm diameter |
| 70 | Providing and fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised- Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 1 0 mm gap for thermal expansion .- Bend 110mm |
| 71 | Providing and fixing floor mounted, white vitreous china single piece,double traps syphonic water closet of approved brand/make, shape,size and pattern including integrated white vitreous china cistern ofcapacity 10 litres with dual flushing system, including all fittings andfixtures with seat cover, cistern fittings, nuts, bolts and gasket etcincluding making connection with the existing P/S trap, complete inall respect as per directions of Engineer-in-Charge. |
| 72 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 73 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 74 | P/F of PVC Floor Trap of approved Quality size 110 mm 160mm |
| 75 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 76 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively |
| 77 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 78 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 79 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggreagate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 80 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarsesand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs)c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge.d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm |
| 81 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. |
| 82 | Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.(1 kg of water proofing material in 50 kg of cement) |
| 83 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. |
| 84 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls herever required : 510x1040mm bowl depth 225mm |
| 85 | Providing and fixing CP Brass 32mm size Bottle Trap of approvedquality & make and as per the direction of Engineer-in-charge. |
| 86 | Providing and fixing of Soap dish holder with all fittings as per direction of Engineer-in-charge. |
| 87 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: 32 mm dia |
| 88 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 89 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 90 | Providing & fixing 15mm nominal bore C.P. brass angle valve for basin mixer and gyser points of approved for conforming to IS : 8931 |
| 91 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931 |
| 92 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover & suitable locking arrangement of Finolex, Sintex or Vectus or equivalent make & making necessary holes for inlet, outlet & overflow pipes but without fittings & the base support for tank |
| 93 | Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. Complete |
| 94 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including allCPVC plain and brass threaded fittings. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer-in-charge. 15mm nominal outer dia pipes. |
| 95 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 15 mm nominal bore |
| 96 | Providing and laying PVC soil waste pipe including bed concrete and all around PVC pipe as per standard design (Prince, finolex, supreme make of 4 kg / cm² pressure. 110mm dia. |
| 97 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 98 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brasssingle hole basin mixer of approved quality and make, including paintingof fittings and brackets, cutting and making good the walls whereverrequired:- White Vitreous China Wash basin size 550x400 mm with a 15 mmCP Brass single hole basin mixer |
| 99 | Providing and fixing toilet paper holder.C.P. brass ( Make essel ,kerovit, euronics, prayag) |
| 100 | Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections |
| 101 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 102 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885 |
| 103 | Provioding. installation, testing and commissioning of Motor Pump (crumpton. Habells) of 1 H.P. capacity incl. starter ( L&T). support wire ,electric cabling. piping (25 mm) and making the whole set up operational all complete. |
| 104 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 105 | Chequerred precast cement concrete tiles 22mm thick in footpath andcourtyard, jointed with neat cement slurry mixed with pigment to matchthe shade of the tiles, including rubbing, cleaning and curing complete,on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) . Medium shade using 50% white cement and 50% ordinarycement |
| 106 | Providing and fixing inauguration stone (granite of size 3/x 2/-6//) including engraving , painting, writing and const. of pedestal of 5 feet height by way of brick work , plastering , tiling and painting. |
| 107 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured). Suspended floors, roofs, landings, beams and balconies (plan area to be measured) |
| 108 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase |
| 109 | Providing and fixing PVC pennelling for false ceiling including cutting, fixing of light panesl etc complete job |
| 110 | Providing and fixing Plantex wall panels for interior wall décor / 3D wall panel including cutting fixing of light panels complete job |
| 111 | Providing and fixing PVC UV glossy sheet wall panel for interior including cutting fixing of light panels complete job |
| 112 | Providing and fixing PVC wall panelling of superior quality including cutting fixing of light panels complete job |
| 113 | carriages of materials by mechinical trancsport incl. loading, unloading and stacking complete |
| 114 | Stone agg. 40mm Above for an avg lead of 4 kms |
| 115 | Stone agg. Below 40mm for an avg lead of 4 kms |
| 116 | sand for an avg lead of 4 kms |
| 117 | Bricks for an avg lead of 4 kms |
| 118 | Disposal of building rubbish/ mulba for an avg lead of 1 km |
| 119 | Providing comprehensive consultancy services including geotechnical investigation; preparation of detailed estimate and BOQ as per JKSOR/PWD-2022 ; architectural planning; civil, structural, electrical, plumbing, fire-fighting, mechanical and utility service drawings; structural analysis and design of the building/structure considering safe bearing capacity of soil and all applicable load combinations including dead load, live load, wind load, seismic/earthquake load, etc., in accordance with IS 875, IS 1893 and other relevant Indian Standards; submission of complete design calculations, analysis reports and calculation sheets to the department; vetting of designs/drawings from DIQC/IIT/NIT/GCET Jammu or other approved authority; incorporation of observations thereof; placement/layout of building at site; and preparation and submission of all Good-for-Construction (GFC) drawings and documents required for execution and approval of the project. Please Enable Macros to View BoQ information |