| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles above 25 mm and upto 40 mm |
| 2 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc.,disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge. |
| 3 | Earthwork in excavation by manual means in trenches for foundation, drains, pipes, cables etc (not exceeding 1.5 M, in width)and for shafts, wells, cesspits and the like not exceeding 10Sqm on plan, depthup to 1.5M including disposal of excavated earth up to50mtrs from cutting edge, disposed earth is to be leveled and neatly dressed in all kinds of soil |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 5 | \\"Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)\\". |
| 6 | Providing and laying Reinforced cement concrete work 1:1.5:3 ( 1 cement :1.5 course sand : 3 gradedstone aggregate 20mm nominal size) in foundations, walls (any thickness) including attached plasters, buttresses, plinth and string courses, columns, pillars, piers, posts, struts, beams, suspended floors, landings, balconies, shelves, chajjas, lintels, bands, stair cases, spiral stair cases etc. up to floor V-level excluding cost of centering shuttering and finishingand reinforcement |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors,roofs, landings, balconies and access platforms |
| 8 | \\"Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete upto plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more\\" |
| 9 | Centering and Shuttering including strutting, propping etc. and removal of Formwork for foundation complete job |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 11 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 12 | P/F of 60mm thick interlocking paver tile to be laid in cement mortar 1:4 mix & fill joint with C.mortar 1:3 mix complete job |
| 13 | Laying old cement concrete interlocking paver block of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. All complete as the directions of Enghineer-in-charge |
| 14 | Providing and applying white cement based putty of 1mm thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 15 | Distemper with oil bound washable distemper of approved brand and manufacture to give an even shadenew work (two or more coats ) over and including priming coat with cement primer including all carriagesand cost of materials involved |
| 16 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coat applied @ 1.67 liter/ 1 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 Sqm |
| 17 | Providing and fixing of following size of PVC (Prince make) Pipe including C/O (B-Type, specified adhesive.100mm diaPipes PVCPrince. |
| 18 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand includingfinishing the top smooth and curing complete |
| 19 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a primingcoat of approved steel primer.Using M.S. angles 40x40x6mm for diagonal braces |
| 20 | Providing and fixing on wall face un-plasticized Rigid PVC rain waterpipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.(i) Single socketed pipes 75 mm diametre |
| 21 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours andshades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600mm |
| 22 | Supplying and filling with RBM complete all job. |
| 23 | \\"Providing and laying integral cement based treatment for water proofing on horizontal surface at alldepth below ground level for underground structures as directed by Engineer-in-Charge and consisting of :i) 1st layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS: 2645 in the recommended proportion over the levelling course (levelling course to be paid separately).Joints sealed and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with waterproofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm sqm thoroughly embedded in the 2nd l Using roughkota stone.\\" |
| 24 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conformingto ISI: 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall bepaid separately. |
| 25 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not lessthan 690 gms. |
| 26 | Providing and fixing of Electrical points (complete fitting) |
| 27 | Removal of Excavated Malba dismantled unserviceable material from site of work. |
| 28 | Providing and Fixing of inaguration stone |
| 29 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and makinggood the wall: 15 mm dia. nominal bore |
| 30 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 31 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.bend 75 mm |
| 32 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Single tee without door 75x75x75 mm |
| 33 | Carriage of material 10 KM by mechanical transportation &By ManualLabour including loading, unloadingand stacking for lead less than 0.50 kme) - Sand |
| 34 | Carriage of material 10 KM by mechanical transportation &By ManualLabour including loading, unloadingand stacking for lead less than 0.50 kme) -Stone aggregate upto 40mm and above |
| 35 | Carriage of material 10 KM by mechanical transportation &By ManualLabour including loading, unloadingand stacking for lead less than 0.50 kme) -Stone aggegate below 40mm Please Enable Macros to View BoQ information |