| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil |
| 2 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:a) 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 4 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 5 | Providing and laying cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips etc. all complete as per direction of Engineer-in-charge.40 mm thick with 20 mm stone aggregate |
| 6 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing, and reinforcement.-All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Centering shuttering including struttings, propping etc. and removal of form work for:a) Foundations, footings, bases for columns etc for mass concrete with timber plank. |
| 8 | b) Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
| 9 | c) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 10 | d) Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 11 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 12 | First class brick work in foundation and plinth including cost of all materials as required complete:-a) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 13 | First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:-a) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 14 | Half brick masonary work with first class bricks in foundation and plinth including cost of all materials as required complete :a) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 15 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 16 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :a) Karai wood |
| 17 | Providing and fixing panelled / or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked bright finished / black enamelled M.S butt hinges with necessary screws excluding panelling and or glazing, which will be paid for separately but including the wooden beading of 20 × 12 mm for fixing panelling and or glazing as per direction of Engineer-In-Charge.A) Local teak wooda) 35 mm thick shutters |
| 18 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 19 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutter for doors windows and clerestory windows (Area of opening for panel inserts ex/c portion inside grooves or rebates to measur). Panelling or penaled of panelled and glazed shutter 25 to 40 mm thickA) Local teak wood 16mm thick |
| 20 | Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm longbrackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19×19mm MS square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame . The door frame to be fixed to the wall usuing MS screws of 65/100 mm size complete as per manufacturers' specification and direction of Engineer-In-Charge. |
| 21 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 22 | Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge.450 mm X 300 mm in all shades and design |
| 23 | Providing and laying 1st class quality ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. all complete as per direction of the Engineer in-charge..Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles300 mm x 300 mm in all shades and designs |
| 24 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge.Soluble Salt Stainfree vitrified tiles (Glossy)Size of tile 600 mm x 600 mm |
| 25 | Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for re-plastering or re-pointing including disposal of rubbish to the dumping ground with all leads and lifts etc.complete as per direction of the Engineer- in-charge. |
| 26 | Renewing glass panes with putty and nails wherever necessary in/c. racking out the old putty:a) Float glass panes of thickness 4 mm. |
| 27 | 12 mm cement plaster of mixa) In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 28 | 15 mm cement plaster on the rough side of single or half brick wall of mix:a) In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 29 | 6 mm cement plaster of mix.a) In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 30 | Distempering with Ist quality acrylic washable distemper of approved brand and manufacture and of required shade on old work ( one or more coats) to give an even shade as required complete as per direction of the Engineer-in-charge. |
| 31 | Distempering with Ist quality acrylic washable distemper ( ready mixed) having VOC content less than 50 grams/litre of approved brand and manufacture of required shade and colour complete as per manufactures specification (Payment shall be made after submission of test certificate issued by the manufacturer)two or more coats on new work |
| 32 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats applied @ 3.84 kg/10 sqm) |
| 33 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture on old work ( one or more coats ) including preparation of surface as required complete as per direction of theEngineer in charge. |
| 34 | Applying priming coat [Payment shall be made after submission of Test Certificate issued by the Manufacrurer]a) With ready mixed pink primer of approved brand and manufacture on wood work ( hard & soft wood ). |
| 35 | b) with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel, galvanised iron / steel work. |
| 36 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.( Payment shall be made after submission of test certificate issued by the manufacturer)two or more coats on new work |
| 37 | Painting with synthetic enamel paint ( one or more coats ) of required colour of approved brand and manufacture on old work to give an even shade including preparation of surface as required complete as per direction of the Engineer in charge. |
| 38 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 39 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever),conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 40 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 41 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.a) 450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms. |
| 42 | b) 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 43 | Providing and fixing P.V.C. Low level flushing cistern with manually controlled device ( handle lever) conforming to IS:7231, with all fittings and fixtures complete.10 litre- capacity-white |
| 44 | Providing and fixing Precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning etc. all complete as per direction of Engineer-in-charge.In dark shade using ordinary cement |
| 45 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugsscrews etc. |
| 46 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63mm thick with zinc coating not less than 275gm/m |
| 47 | Providing ridges or hips of width 60 cm over all width plain G.S fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. Limpet and bitumen washers complete.0.63mm thick with zinc coating not less than 275gm/m2 |
| 48 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 49 | Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I. fittings and clamps, including cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge.Internal work - Exposed on wall. i) 15 mm dia. nominal bore |
| 50 | ii) 20 mm dia. nominal bore |
| 51 | iii) 25 mm dia. nominal bore |
| 52 | iv) 40 mm dia. nominal bore |
| 53 | Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling etc. complete as per CPWD specification and direction of the Engineer - in - charge.External work15 mm dia. nominal bore |
| 54 | 20 mm dia. nominal bore |
| 55 | 25 mm dia. nominal bore |
| 56 | 40 mm dia. nominal bore |
| 57 | Providing and fixing soil, waste and vent pipes:100 mm dia.Sand cast iron S&S pipe as per IS: 1729. |
| 58 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste & vent pipes (working pressure 6 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Single socketed pipe - 110 mm OD |
| 59 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC soil, waste & vent pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:I) Coupleri) 110 mm |
| 60 | II) Bend 87.5°i) 110mm |
| 61 | Providing and fixing brass bib cock of approved quality :i) 15 mm dia. nominal bore |
| 62 | Providing and fixing brass stop cock of approved quality :i) 15 mm dia. nominal bore |
| 63 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: i) 100 mm diameter |
| 64 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making neccessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 65 | Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with :Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 66 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification Please Enable Macros to View BoQ information |