| 1 | Supply, Installation, Testing and Commissioning (SITC) of 19\\" rack mount Antenna and Power Distribution System, designed to distribute RF signal over one pair of diversity antennas and to provide input signal and DC power supply up to four (4) dual receiver units, suitable for RF frequency range of 450–950 MHz, complete with front panel LED indicators for power and signal status, necessary RF connectors, interconnecting cables, mounting accessories, earthing, and all allied works required for proper installation and satisfactory operation, as per CPWD specifications and as directed by Engineer-in-Charge. |
| 2 | Supply & Laying of BNC Cable to connect Antena Distribution System with existing Val Audio Wireless Microphones complete as reqd. |
| 3 | Supply, Installation, Testing and Commissioning of BNC Connectors to connect Antena Distribution System with existing Val Audio Wireless Microphones complete as reqd. |
| 4 | Supply and drawing following sizes of PVC insulated Copper conductor unarmoured multicore cable in the existing wall and brackets from cable termination connector to the fitting i/c providing suitable lugs connetions etc. as reqd. a) 3 core 2.5 Sq.mm |
| 5 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 8 way (4 + 24), Double door |
| 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required.a) Single pole |
| 7 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. a) 100 A,30KA,FPMCCB |
| 8 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 2.5 sq. mm |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as reqd. a) 25 mm |
| 10 | Providing and fixing of PVC Trunking of following sizes complete with flexible cover, joint, endcap, cover , partition clip wherever reqd. on surface of wall/existing mounting etc. as required. a) 105 mm x 50 mm |
| 11 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 12 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). a) 1.5 TR with 5 Star BEE Rating |
| 13 | Supplying & Fixing of 4 KVA capacity automatic voltage stabilizer with time delay relay and high/low voltage trip facility input voltage 150V to 290V±10% and output voltage 220±10% with copper flexible cable connection etc. as required at site. |
| 14 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. a) For 8 way, Double door TPN MCBDB Please Enable Macros to View BoQ information |