| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc, or for foundation, etc, for shafts, wells, cesspits, manholes, pier holes, etc, n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 2 | M&L for PCC 1:4:8(nominal mix) type D-2 (using 40 mm graded crushed stone aggregate), as in foundation filling and mass concrete, complete all as specified and directed. |
| 3 | Use and waste of formwork to sides of concrete foundation,footing,bases of columns,rafts and rafts beams ,sides and soffits (if any) of foundation and plinth beams and similar work ,vertical or to batter for fair finished surfaces of concrete complete all as specified and directed. |
| 4 | Use and waste of formwork to sides of pillars, posts, struts, columns etc for fair finished surface of concrete,complete all as specified and directed. |
| 5 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc, also splays between floors and beams flat for rough finished surfaces of concrete, complete all as specified and directed. |
| 6 | Use and waste of formwork to soffits of flat and fair faces of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 7 | M&L for RCC M-25 (using 20mm graded stone aggretate) design mix for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc,complete all as specified and directed. |
| 8 | M&L for RCC M-25 (using 20mm graded stone aggretate) design mix in columns ,pillars,piers,post and struts ,all as specified and directed complete all as specified and directed. |
| 9 | M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in beams, cantilevers, bressumn- ers, lintels over 1.5m span all as sppcified complete all as specified and directed. |
| 10 | M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in slabs supported on walls , beams, and columns in floors, roofs landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 11 | M&L for TMT bar 10 mm and over cut to length, bend to shape required including cranking, bending spirally for hoopings for cols, hooking ends and binding with with ad including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 12 | M & L for TMT bars 5mm dia and over upto and including 10mm dia as in stirrups cut to length bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with and incl mild steel wiere (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 13 | M&L for Brickwork with sub class 'B' (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and directed. |
| 14 | Material & labour for Rendering 10 mm thick CM 1:6 on brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed. |
| 15 | M & L for Rendering 15 mm thick in two coats i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even & smooth without using extra cement complete all as specified and directed.Note: Waterproofing liquid compound shall be measured and paid seprately. |
| 16 | Supply only liquid water proofing liquid complete all as specified and directed. |
| 17 | M&L for two coat of oil bound distemper over priming surface with chalk whitening on plastered ,prepatory to distempering to new plastered surfaces including preparation of wall surfaces complete all as specified and directed. |
| 18 | Preperation of new surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 19 | Two coat of white washing on ceiling including preparation of new plastered surface complete all as specified and directed. |
| 20 | Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 21 | Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed. |
| 22 | Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. |
| 23 | Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 24 | Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed. |
| 25 | M & L for hard core broken stone of gauge n.exc 63 mm deposited , spread and levelled in layers n.exc 15 cm thick, watered rammed to a true surface complete all as specified and directed. |
| 26 | M&L for 75 mm thick cement concrete 1:4:8 type C-2 (using 40mm graded crushed stone agg) as in Sub base all as specified and directed complete all as specified and directed. |
| 27 | M&L for 25 mm thick PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in floor finished even and rought to received the topping layer complete all as specified and directed. |
| 28 | M & L for providing 75 mm thick PCC (1:2:4) type B-2 using 40mm graded crushed stone aggregate as in plinth protection including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified and directed. |
| 29 | M&L for RCC Nominal mix 1:2:4 type B1(using 20 mm graded crushed stone aggregate) in chajjas complete all as specified and directed. |
| 30 | Formwork to flat chullah hoods,chajjas,troughs and similar items including edges fair finished surfaces, complete all as specified and directed. |
| 31 | Returning filling in with approved excavated earth, incl spreading leveling, watering and well ramming in layers n exc 25 cm thick with soft loose soil complete all as specified and directed. |
| 32 | Removing excavated material n. exc.50mtr and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed. |
| 33 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 34 | M&L PCC 1:3:6 type C2 using 40mm graded stone aggregate as in Sub base complete all as specified and directed. |
| 35 | M&L for 75 mm thick PCC 1:3:6, type C-2 (Using 40 mm graded crushed stone aggregate) as in sub base etc and finished even without using extra cement, complete all as specified and directed. |
| 36 | M&L 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in plinth protection/flooring finished even and smooth without using extra cement complete all as specified and directed. |
| 37 | M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick or concrete surfaces, as on external surface such as chajja, parapet, finished even and fair, complete all as specified and directed. |
| 38 | M&L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick or concrete surfaces, as on internal surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 39 | M&L Preparing of new plastered wall surface and applying two coat white wash on newly plastered surfaces, complete all as specified and directed. |
| 40 | Material & Labour for appplying two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 :2004, Alkali & fungal resistance dirt resistance exterior paint of required shade ( Company Depot Tinted ) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces of wall complete including preparation of surfaces of walls complete all as specified and directed. |
| 41 | Excavating in post holes in soft/loose soil (or similar holes) each n. exc 0.5 Cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed. |
| 42 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 43 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 44 | S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. grade St.-240 complete all as specified and directed. |
| 45 | S & F Rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe-290(Gde-E-165)quality A, complete all as specified and directed. |
| 46 | M&L preparation of new steel surfaces of any description not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide,zinc chrome primer complete all as specified and directed. |
| 47 | Providing, cement concrete 1:2:4 in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 48 | M&L 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate laid in alternative bays area not exc 2 sqm each as in plinth protection laid to slope of 1 in 12 including finishing the surface even and smooth with using extra cement complete all as specified and directed. |
| 49 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 50 | M&L chequered coloured cement concrete colour tiles, of size 300 x 300 x25mm thick or euquivalent size as in machine pressed set, jointed and pointed in neat cement slurry with grey cement and no pigment, over and incl 20mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 51 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded complete all as specified and directed. |
| 52 | M&L coloured chequered cement concrete tiles, machine pressed, factory made of size 20cmx20cmx25mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 53 | All as item No-52 but except tile |
| 54 | M&L Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size /shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 55 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 56 | M&L for preparation of old steel, iron, wood, concrete, brick surfaces of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint over one coat of red oxide primer if required complete all as specified and directed. Colour to be approved by GE. |
| 57 | M&L for walling of random rubble stone masonry built in cement mortar 1:6 uncourse, well bonded, bedded and solidly hearted and pointing surface in contact with earth in the same mortar incl providing weep holes as the work proceeds complete including demolition complete all as specified and directed. |
| 58 | Preparation of old plasteres/unplastered wall surface including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of cement base paint upto 15m height, complete all as specified and directed. |
| 59 | M&L for Preparation old surface by removing by scrapping, brushing etc including making surface clean, dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and filling holes, dents, cracks with mixture of white cement and applying One coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and directed. |
| 60 | M&L for rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or other than fair face fair faces of brick / concrete surfaces for smooth & even finished complete all as specified and directed. Please Enable Macros to View BoQ information |
| 61 | M&L for rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or other than fair face fair faces of brick / concrete surfaces for smooth & even finished complete all as specified and directed. Please Enable Macros to View BoQ information |