| 1 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 2 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead :Thickness above 10 mm up to 25 mm |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 4 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 5 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalentdesign mix) |
| 6 | Dismantling old carpet with under lay including stacking of the same in roll at designated space complete in all respects as per direction of Engineer - in - charge. |
| 7 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 8 | Dismantling of plumbing pipes and associated fixtures such as sinks, faucets etc. including stacking of dismantled materials at designated place complete in all respects as per direction of Engineer - in - charge. |
| 9 | Dismantling of 8 mm thick HPL cladding and roofing mounted on steel structure including required scaffolding and stacking of dismantled material within 50 mtr lead complete in all respect as per direction of Engineer - in - charge. |
| 10 | Dismantling of mirror cladding on wall surface with back ply including stacking of dismantled material complete in all respect per direction of Engineer - in - charge. |
| 11 | Dismantling of glass panes of widows including stacking of dismantled material at designated place complete in all respect as per direction of Engineer - in - charge. |
| 12 | Removal of heavy curtains and dismantling of curtain tracks including all fitting, brackets etc and stacking of the dismantled/ removed materials at designated place, complete in all respects as per direction of engineer- in- charge |
| 13 | Dismantling of vertical garden pots installed on the wall surface including frame work, stacking and disposal of the unserviceable material, complete in all respect as per direction of Engineer - in - charge. |
| 14 | Dismantling of polycarbonate sheet roofing fixed on steel structure including all fixtures & fastners with providing required scaffolding and stacking of the material at designated place, complete all respects as per direction of Engineer - in - charge. |
| 15 | Dismantling of 75 mm thick sandwitch panel metro sheet roofing mounted on steel structure including all fixture & fastners with scaffolding and stacking as per direction of Engineer - in - charge. |
| 16 | Dismantling of fabric paneling from columns including back ply and base frame and stacking of dismantled material at designated place, complete in all respect as per direction of Engineer - in - charge. |
| 17 | Dismantling of aluminium frame work of windows including stacking of serviceable materials at designated place complete in all respect as per direction of Engineer - in - charge. |
| 18 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineering-in-charge. |
| 19 | Dismantling of decorative ceiling panel with fixture and decorative material and glass panels including stacking of the same complete in all respect as per direction of Engineer - in - charge. |
| 20 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived fromnatural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 21 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :White sand stone - exposed face fine dressed with rough backing .40 mm thick |
| 22 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 23 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 24 | Providing and fixing Glazing panels of 12 mm Plain toughened glass as per required size including EPDM rubber gasket complete in all respect as per direction of Engineer - in - charge etc complete. |
| 25 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum board conforming to IS 2095: part I : 2011 (Board with BIS certification marks). |
| 26 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood. |
| 27 | Providing and fixing flat pressed three layer particle or graded plain wood board medium density exterior grade (Grade I) FPT-I, conforming and marked to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately):12 mm thick |
| 28 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting ,unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. Please Enable Macros to View BoQ information |