|
| 1 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge |
| 2 | Dismantling of wall/ceiling board as in ceiling and lining of any gauge or any thickness including cover fillets complete all as specified and directed by Engineer-in-Charge |
| 3 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge |
| 4 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge |
| 5 | S & F 0.63mm thick corrugated galvanised steel sheetings with two corrugation side lap fixed with ‘L’ type or ‘J’ type cranked hook bolts, nuts and washers as in roof , wall etc with grade of zinc coating 275 gm/sqmetc complete all as specified and directed by Engineer-in-Charge |
| 6 | S & F 0.80mm thick plain, Galvanised, mild steel sheeting(ISI marked) gade 'O' with minimum 120grams/square metre with two corrugation side lap and at least 150mm end lap, fixed with 'L' type or 'J' type or cranked hook complete all as specified and directed by Engineer-in-Charge |
| 7 | M & L 12mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work in wall / ceiling, flat or sloping complete all as specified and directed by Engineer-in-Charge |
| 8 | M & L for PVC panelling made up of PVC hollow panels 25/30 cm in width and 10mm thickness, interlocking pattern, of approved shade and design, fixed to walls or ceilings all as per the manufacturer's instructions, fixed in repirs, complete all as specified and directed by Engineer-in-Charge |
| 9 | S & F anodised aluminium snap grid of size 605 x 605,, frame work for false celingcomplete all as specified and directed by Engineer-in-Charge |
| 10 | M & L for 4mm thick non asbestos fibre cement building boards fixed or laid /inserted to aluminium frame work with screws fixed in ceiling flat or sloping complete all as specified and directed by Engineer-in-Charge |
| 11 | M & L Brickwork cement mortor 1:6 with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in etc complete all as specified and directed by Engineer-in-Charge |
| 12 | Material and labour for half brick thick work with sub class 'B' old size bricks built in cement mortar 1:4 straight or curved on plan to any radius complete all as specified and directed by Engineer-in-Charge |
| 13 | M & L for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair complete all as specified and directed by Engineer-in-Charge |
| 14 | M & L and labour for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair complete all as specified and directed by Engineer-in-Charge |
| 15 | M&L Plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cills, lintels upto 1.5 metre clear span, steps, seismic and other similar band, plinth course, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stone, bed plates, kerbs etc and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete, complete all as specified and directed by Engineer-in-Charge |
| 16 | M & L for applying two coats of cement base paint over one coat of primer on plastered surfaces of walls including preparation of new or previously untreated surfaces complete all as specified and directed by Engineer-in-Charge |
| 17 | M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge |
| 18 | S & F PVC casing capping 25x16mm medium duty with fixing accessories complete all as specified & by Engineer-in-charge |
| 19 | Taking down copper/aluminium point wiring (light,fan,socket or power) complete, including fixture and fittings such as switches,ceiling roses, pendants, regulators,sockets, light fittings etc. and refixing the same in old /new conduit or casing capping as per site requirement after wall paneling/ceiling complete all as specified & by Engineer-in-charge |
| 20 | S & F in repair PVC rectangular block for mounting, switches, sockets , fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed by Engineer-in-Charge |
| 21 | M&L Plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cills, lintels upto 1.5 metre clear span, steps, seismic and other similar band, plinth course, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stone, bed plates, kerbs etc and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete all as specified and directed by Engineer-in-Charge Please Enable Macros to View BoQ information |