| 1 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge |
| 2 | Dismantling of wall/ceiling board as in ceiling and lining of any gauge or any thickness including cover fillets complete all as specified and directed by Engineer-in-Charge |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge |
| 4 | Dismantling posts or struts embedded in Concrete, brick work, masonry, etc. (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed by Engineer-in-Charge |
| 5 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge |
| 6 | M & L for cement concrete type C2 1:3:6 (40mm graded aggregates)as in drain wall side complete all as specified and directed by Engineer-in-Charge |
| 7 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge |
| 8 | S & F 0.63mm thick corrugated galvanised steel sheetings with two corrugation side lap fixed with ‘L’ type or ‘J’ type cranked hook bolts, nuts and washers as in roof , wall etc with grade of zinc coating 275 gm/sqmetc complete all as specified and directed by Engineer-in-Charge |
| 9 | S & F 0.80mm thick plain, Galvanised, mild steel sheeting(ISI marked) gade 'O' with minimum 120grams/square metre with two corrugation side lap and at least 150mm end lap, fixed with 'L' type or 'J' type or cranked hook complete all as spd and directed. |
| 10 | M & L 12mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work in wall / ceiling, flat or sloping complete all as specified and directed by Engineer-in-Charge |
| 11 | M & L for PVC panelling made up of PVC hollow panels 25/30 cm in width and 10mm thickness, interlocking pattern, of approved shade and design, fixed to walls or ceilings all as per the manufacturer's instructions, fixed in repirs, complete all as specified and directed by Engineer-in-Charge |
| 12 | S & F anodised aluminium snap grid of size 605 x 605,, frame work for false celing complete all as specified. |
| 13 | M & L for 4mm thick non asbestos fibre cement building boards fixed or laid /inserted to aluminium frame work with screws fixed in ceiling flat or sloping complete all as specified and directed by Engineer-in-Charge |
| 14 | S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge |
| 15 | M & L for preparation of new and previously un-treated steel surfaces of any description, not otherwise described over 10cmwidth or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge |
| 16 | S & F PVC casing capping 25x16mm medium duty with fixing accessories complete all as specified & by Engineer-in-charge |
| 17 | Taking down copper/aluminium point wiring (light,fan,socket or power) complete, including fixture and fittings such as switches,ceiling roses, pendants, regulators,sockets, light fittings etc. and refixing the same in old /new conduit or casing capping as per site requirement after wall paneling/ceiling complete all as specified & by Engineer-in-charge |
| 18 | S & F in repair PVC rectangular block for mounting, switches, sockets , fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed by Engineer-in-Charge |
| 19 | M & L for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair complete all as specified and directed by Engineer-in-Charge |
| 20 | M&L Plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cills, lintels upto 1.5 metre clear span, steps, seismic and other similar band, plinth course, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stone, bed plates, kerbs etc and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete all as specified and directed by Engineer-in-Charge |
| 21 | M & L for applying two coats of cement base paint over one coat of primer on plastered surfaces of walls including preparation of new or previously untreated surfaces complete all as specified and directed by Engineer-in-Charge Please Enable Macros to View BoQ information |