| 1 | Dismantling the existing Burner assembly of heating plant of capacity 2 Lakh Kcal/ hr for repairs and replacement of coupling for blower and motor of burner assembly and refixing the same position including testing complete all as specified and directed. |
| 2 | Dismantling the existing Boiler assembly of heating plant of capacity 2 Lakh Kcal/ hr for de- carbonization , Descaling and refractory cement and assemble the same and testing complete all as specified and directed. |
| 3 | M&L for de- carbonization of Boiler assembly of heating plant of capacity 2 Lakh Kcal/ hr by using brush and vaccum cleaner complete all as specified and directed. |
| 4 | M&L for Descaling of Boiler by circulating the Descaling chemical using circulating pump into the boiler and kept it for approx 4 hours for descaling and flushing off the chemical after descaling of boiler complete all as specified and directed. |
| 5 | M&L for refractory cement / heat resistance cement of Boiler assembly of heating plant complete all as specified and directed. |
| 6 | S&F in repair of ball cock valve heavy duty made out of Brass of size 20mm complete all as specified and directed. |
| 7 | Supply and fixing in replacement of Solenoid Valve suitable for burner heating plant of capacity 2 LakhKcal/hr RAPID THERM Boiler complete all as specified and directed. |
| 8 | S&F in repair of photo cell sensor suitable for burner heating plant of capacity 2 LakhKcal/hr RAPID THERM Boiler Make - COFI complete all as specified and directed. |
| 9 | S&F in repair Hydraulic Pressure gauge showing reading 0-20 bar with accuracy +/- 2.5% to be connected with 15 mm dia GI Pipe complete with suitable size of battery complete all accessories and protection cover. |
| 10 | S&F in repair Digital temperature controller (DTC) suitable for burner heating plant of capacity 2 LakhKcal/hr RAPID THERM Boiler complete all as specified and directed. |
| 11 | Supply and fixing in replacement of ignition Electrode suitable for burner heating plant of capacity 2 LakhKcal/hr RAPID THERM Boiler complete all as specified and directed. |
| 12 | Supply and fixing in replacement of igintion Transformer suitable for burner heating plant of capacity 2 LakhKcal/hr RAPID THERM Boiler complete all as specified and directed. |
| 13 | Supply and fixing in replacement of Fuel feed pump with indicator suitable for burner heating plant of capacity 2 LakhKcal/hr RAPID THERM Boiler complete all as specified and directed. |
| 14 | S&F in repair of Nozzel 60 degree complete all as specified and directed. Make : Danfoss or equivalents make. |
| 15 | Replacement of old unserviceable minor part for the control panel including repairing of wiring etc as per existing, complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F in repair ON/OFF selector switch with indicator suitable for burner heating plant of capacity 2 LakhKcal/hr RAPID THERM Boiler complete all as specified and directed. |
| 17 | S&F in repair Thermostat suitable for burner heating plant of capacity 2 LakhKcal/hr RAPID THERM Boiler complete all as specified and directed. |
| 18 | S&Fin repair Sequence controller suitable for burner heating plant of capacity 2 LakhKcal/hr RAPID THERM Boiler complete all as specified and directed. |
| 19 | S&F in repair Contactor 25A, 230V/440V suitable for 2 Lakh Kcal Boiler RAPID THERM Boiler including testing complete all as specified and directed. Make-L&T / ABB / Schnider |
| 20 | S&F in repair of Contactor 230/ 440V including testing complete all as specified and directed. Make-L&T / ABB / Schnider |
| 21 | S&F in repair Relay 4.5 - 7.5 Amps, 3 Phase, 50 HZ, 415 Volts suitable for 2 Lakh Kcal Boiler RAPID THERM Boiler including testing complete all as specified and directed. Make-L&T / ABB / Schnider |
| 22 | S&F in repair Relay 6 - 10 Amps,3 Phase, 50HZ, 415 Volts including testing complete all as specified and directed. Make-L&T / ABB / Schnider |
| 23 | S&F in repair Diesel filter assembly with drain port complete as per sample. |
| 24 | S&F in repair fuel pipe for burner as per sample. |
| 25 | M&L for complete rewinding of electric motor of capacity 5 HP 3 phase 415 volt with super enameled copper wire of superior quality as per existing gauge including varnishing, insulating material complete all as directed and including reassembling fixing in position making connection testing, commissioning & transporting complete all as specified and directed by Engr-in-Charge. |
| 26 | M&L for complete rewinding of electric motor of capacity 1 HP single phase 230 volt with super enameled copper wire of superior quality as per existing gauge including varnishing, insulating material complete all as directed and including reassembling fixing in position making connection testing, commissioning & transporting complete all as specified and directed by Engr-in-Charge. |
| 27 | All as per item No 26 above but Capacity 0.5 HP single phase 230 Volts. |
| 28 | Repair of chimney 7mtr high complete with welding including iron pieces, plates, outlet cover and necessary modification and Cleaning complete removal of all kinds of dust both internal and external parts and free from all kind of dust/dirty spots of chimney, complete all as specified and directed by Engr-in-Charge. |
| 29 | M&L for elastomeric Nitrile rubber foam insulation sheet for ducts having anti microbial properties having thickness 10 mm with suitable adhesive complete all as specified. |
| 30 | Dismantling of unserviceable/damaged HEPA Filters and supply and fixing of HEPA Filters with Al box and flange type of size 640 x 460 x 50 mm with frame having efficiency of 3 microns complete all as specified. |
| 31 | M&L for Cleaning of existing HEPA Filters with pressurized potable water by using pressure pump and water spray gun, Dry the filters with compressed air after cleaning complete all as specified. |
| 32 | Supply and topping up of Antifreeze (Coolant) suitable for -35 to -40 degree celsius to be filled in reservoir tank for central heating system as instructed by Engr-in-Charge. |
| 33 | S&F of threaded Thermometer having range -50 to +100 degree celsius with accuracy +/-2.5% to be fixed on 15 mm dia GI pipe complete with all accessories. |
| 34 | M&L for rewinding of AHU Blower Motor cap 5 HP and testing after repair complete all as specified. |
| 35 | M&L charges for servicing of air handling units including Blower cleaning, balancing of blower motor pully complete all as specified. |
| 36 | S&F in replacement of supply air diffuser alongwith collar damper of size 600 x 600, Neck size 450 x 4550mm all as specified. |
| 37 | M&L for General maintenance, inspection and servicing of Chiller unit by (make-Bluestar model no. XAC2S-010R2) cleaning of condenser and evaporator coils of the chiller unit by using specialized cleaning solution and pressure washing, inspections of the compressor and water pump for leaks, noise, and proper functionality, Verifying the integrity of electrical components, including wiring, breakers and sensors, parts, lubrication of moving parts, checking of any refrigerant leaks, checking performance testing and optimization. |
| 38 | M&L for Repair/replacement of faulty components, fixing any Refrigerant leaks and vaccum testing and performance evaluation after refilling, replacement of worn out gaskets, seal and O-rings for Chiller of capacity 9.2 TR complete all as specified and directed. |
| 39 | Supply and Charging of Refrigerant gas R-407C as per existing for Chiller of capacity 9.2 TR and testing after charging complete all as specified and directed. |
| 40 | Supply and Topping up of Compressor Oil as per existing grade suitable for 9.2 TR capacity chiller complete all as specified and directed. |
| 41 | Supply, installation, testing in replacement of hermetic type scroll compressor unit , suitable for 9.2 TR capacity chiller unit (make-Bluestar model no. XAC2S-010R2) including brazing and with necessary nuts and bolts, copper filter, capillary etc complete all as specified and directed . Note: Compressor will be purchased with guarantee period and must be company sealed. Make : Bluestar/Godrej / LG or equivalent. |
| 42 | S&F in replacement of Expansion Valve as per sample suitable for 9.2 TR capacity chiller complete all as specified and directed. |
| 43 | S&F in replacement of Filters & Driers as per sample suitable for 9.2 TR capacity chiller complete all as specified and directed. |
| 44 | S&F in replacement of Pressure Switches as per sample suitable for 9.2 TR capacity chiller complete all as specified and directed. |
| 45 | S&F in replacement of Control Relays as per sample suitable for 9.2 TR capacity chiller complete all as specified and directed. |
| 46 | S&F in replacement of Fan Motor of cooling tower as per sample suitable for 9.2 TR capacity chiller complete all as specified and directed. |
| 47 | S&F in replacement of Temperature Controller as per sample suitable for 9.2 TR capacity chiller complete all as specified and directed. |
| 48 | Dismantling the existing Burner assembly of Oil fired hot water boiler of capacity 30000 Kcal/ hr for repairs and replacement of coupling for blower and motor of burner assembly and refixing the same position including testing complete all as specified and directed by Engr-in-Charge. |
| 49 | Dismantling the existing Boiler assembly of heating plant of capacity 30000 Kcal/ hr for de- carbonization and assemble the same and testing complete all as specified and directed by Engr-in-Charge. |
| 50 | M&L for de- carbonization of Boiler assembly of heating plant of capacity capacity 30000 Kcal/ hr by using brush and vaccum cleaner or blower complete all as specified and directed by Engr-in-Charge. |
| 51 | S&F in repair of ball cock valve heavy duty made out of gun metal of size 25mm complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F in repair of photo cell sensor suitable for burner of Oil fired hot water boiler of capacity 30000 Kcal/ hr complete all as specified and directed by Engr-in-Charge. |
| 53 | S&F in repair DTC suitable for burner of Oil fired hot water boiler of capacity 30000 Kcal/hr complete all as specified and directed by Engr-in-Charge. |
| 54 | Supply and fixing in replacement of ignition Electrode suitable for burner of Oil fired hot water boiler of capacity 30000 Kcal/hr complete all as specified and directed by Engr-in-Charge. |
| 55 | Supply and fixing in replacement of igintion Transformer suitable for burner of Oil fired hot water boiler of capacity 30000 Kcal/hr complete all as specified and directed by Engr-in-Charge. |
| 56 | Supply and fixing in replacement of Fuel feed pump with indicator suitable for burner of Oil fired hot water boiler of capacity 30000 Kcal/hr complete all as specified and directed by Engr-in-Charge. |
| 57 | S&F in repair of Nozzel 60 degree suitable for burner of Oil fired hot water boiler of capacity 30000 Kcal/hr complete all as specified and directed by Engr-in-Charge. |
| 58 | S&F in repair ON/OFF selector switch with indicator suitable for burner of Oil fired hot water boiler of capacity 30000 Kcal/hr complete all as specified and directed by Engr-in-Charge. |
| 59 | S&F in repair Thermostat suitable for burner of Oil fired hot water boiler of capacity 30000 Kcal/hr complete all as specified and directed by Engr-in-Charge. |
| 60 | S&Fin repair Sequence controller suitable for burner of Oil fired hot water boiler of capacity 30000 Kcal/hr complete all as specified and directed by Engr-in-Charge. |
| 61 | S&Fin repair Solenoid Valve suitable for burner of Oil fired hot water boiler of capacity 30000 Kcal/hr complete all as specified and directed by Engr-in-Charge. |
| 62 | S&F in replacement of chimney exhaust of 6 inch dia made of Auminium sheet including bends and outlet cover complete all as specified and directed by Engr-in-Charge. |
| 63 | Dismantling the existing radiator unit of capacity from 3000 to 6000 K Cal per hour, taking it to nearest workshop cleaning the complete unit with coil shine chemical, detecting the leakage portion by applying nitrogen gas pressure, brazing the leakage portion, refixing the same unit from dismantled location including testing on load complete all as directed at site by Engineer-in- Charge. |
| 64 | Supply and laying 3 layer (inner antimicrobial, outer UV stabilized) ISI marked IS-15801 PP-R pipe and PP-R plain fittings in walls or laying in floors complete of size outer dia 25 mm including all fittings (surface remitting also included). |
| 65 | S&F in repair of ball cock valve heavy duty made out of Brass of size 25mm complete all as specified and directed. |
| 66 | S & F in replacement thermostat suitable for 126/165/195/310 litres capacity refrigerators all as directed. |
| 67 | Supply and Charging of Refrigerant gas as per existing for Refrigerator of capacity 126/165/195/310 and Deep Freezer of capacity 300/320/400/500 ltr capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed. |
| 68 | S&F in replacement of compressor unit , suitable for 165/195 ltr capacity refrigerator including brazing and with necessary nuts and bolts, copper filter, capillary etc complete all as specified and directed . Note: Compressor will be purchased with guarantee period and must be company sealed. Make : Godrej / LG/ Bluestar. |
| 69 | S&F in replacement of compressor unit , suitable for 126 ltr capacity refrigerator including brazing and with necessary nuts and bolts, copper filter, capillary etc complete all as specified and directed . Note: Compressor will be purchased with guarantee period and must be company sealed. Make : Godrej / LG/ Bluestar. |
| 70 | S&F in replacement of compressor unit , suitable for 310 ltr capacity refrigerator including brazing and with necessary nuts and bolts, copper filter, capillary etc complete all as specified and directed . Note: Compressor will be purchased with guarantee period and must be company sealed. Make : Godrej / LG/ Bluestar. |
| 71 | S&F in replacement of copper capillary tube with all fittings for refrigerator of cap 126/165/310 ltr complete all as specified. |
| 72 | Repair to Voltage stabilizer for automatic operation single phase naturally air cooled, indoor type designed for output variation between 170 to 250 V with output voltage stablized at 230 V with accuracy of +/- 2.5 % and capacity 1 KVA and making connection with AC complete all as specified & directed. |
| 73 | Supply and fixing in replacement of water heater storage single phase 230 volt 50 ltrs capacity BEE 5 star rated and grouting 4 nos nut & bolts 90 mm long 12mm dia on wall for fixing and connection pipes including taking out old unsv geyser complete all as specified. Make : Havells / Crompton/Bajaj/Racold. |
| 74 | Supply and fixing in replacement of water heater storage single phase 230 volt 25 ltrs capacity BEE 5 star rated and grouting 4 nos nut & bolts 90 mm long 12mm dia on wall for fixing and connection pipes including taking out old unsv geyser complete all as specified. Make : Havells / Crompton/Bajaj/Racold. |
| 75 | M&L for replacement of unservicible inner shell made of stainless steel 1.5mm thick suitable for Geyser inclusive of glass wool as an insulating material for geyser of capacity 25-50 Ltrs. |
| 76 | M&L for replacement of Thermostat for geyser 0 to 80˚ C complete all as specified and as directed by Engineer-in-charge. |
| 77 | M&L for flexible PVC connection pipe for geyser of length 1.5 feet as per sample. |
| 78 | M&L for replacement of pressure release valve for geyser of 25 ltr having size 15mm dia. |
| 79 | M&L for Replacement of heating element for 25 ltr Geyser capacity round type 1.5 KW as per sample. |
| 80 | M&L for Replacement of heating element for 25 ltr cap Triangle type 1.5 KW as per sample. |
| 81 | M&L for Replacement of Geyser assembly suitable for 25 ltr Geyser as per sample. |
| 82 | Repair and replacement of kerosine oil batti including blower, burner for Hammam 500 as per sample complete all as specified and directed. |
| 83 | S&F brass Tap size15/20 mm for hamam as per sample complete all as specified and directed. |
| 84 | M&L for Replacement of heating element as per sample suitable for 500Ltr Hammam as per sample. |
| 85 | S&F in repair of compressor new sealed unit, suitable for 300/320 ltr capacity deep freezer and testing on full load including brazing and with necessary nuts and bolts, copper filter, capillary etc complete in all respect complete all as specified and directed by Engr-in-charge.Note: Compressor will be purchased with guarantee period and must be company sealed. |
| 86 | S&F in repair of compressor new sealed unit, suitable for 400 ltr capacity deep freezer and testing on full load including brazing and with necessary nuts and bolts, copper filter, capillary etc complete in all respect complete all as specified and directed by Engr-in-charge.Note: Compressor will be purchased with guarantee period and must be company sealed. |
| 87 | S&F in repair of compressor new sealed unit, suitable for 500 ltr capacity deep freezer and testing on full load including brazing and with necessary nuts and bolts, copper filter, capillary etc complete in all respect complete all as specified and directed by Engr-in-charge.Note: Compressor will be purchased with guarantee period and must be company sealed. |
| 88 | S&F in replacement of copper capillary tube with all fittings for deep freezeer of cap 300 ltr to 500 Ltr complete all as specified and directed by Engr-in-charge. |
| 89 | M&L for copper tube of size 1/4 inch for refrigerator and deep freezeer complete all as specified and directed by Engr-in-charge. |
| 90 | S & F in replacement over load protector relay as per existing suitable for up to 500 Litres capacity deep freezer and Refrigerators complete all as specified and as directed. |
| 91 | S & F in replacement running capacitor suitable for up to 500 Litres capacity deep freezer and Refrigerators complete all as specified and as directed. |
| 92 | S & F in replacement thermostat suitable for up to 500 Litres capacity deep freezer complete all as specified and as directed. |
| 93 | S & F in replacement starting capacitor suitable for up to 500 Litres capacity deep freezer and Refrigerators complete all as specified and as directed. |
| 94 | S & F in repair of PVC insulated copper cable of size 2.5 sqmm 3 core complete all as specified and directed by Engr-in-charge. |
| 95 | M&L for cleaning and internal inspection of ducting of central heating system by advanced robotic duct cleaning machine including camera based inspection, brushing, vaccuming and removal of dust, debris and microbial contaminants from inside surfaces of ducts, bends, joints and diffusers, complete pre and post cleaning inspection (camera based) alongwith ensuring hygienic and contamination-free duct system all as specified and directed by Enge-in-Charge |
| 96 | Supply, fixing, installation,testing and commissioning in replacement of wall mounted aluminium heating panel of size 600x300x18 mm, capacity 65 watts,48V, suitable for operation on single phase AC supply, complete with, fixing accessories, connection to existing wiring complete all as specified and directed by Engr-in-Charge |
| 97 | M&L for Repair and servicing of steam generator associated with Air Handling Unit (AHU) including connection of steam lance with required accessories and making hole into the ducts of suitable size and cleaning, replacement of damaged parts,connection of piping with insulation to the system either AHU/Ducts including connection of water inlet, drain, and electrical control wiring, ensuring proper humidity control operation with testing and commissioning complete all as specified and directed by Engr-in-Charge. |
| 98 | M&L for cleaning of diesel tank cap 1000 Ltr by dismantling all connected parts and making leak proof by welding and refixing the same at its original position and connecting all dismantled parts and testing the same complete all as specified and directed by Engr-in-Charge. |
| 99 | M&L in replacement butterfly valve 50 mm including nuts,bolts and other accesories suitable for 50 mm bore pipe complete all as specified and directed. |
| 100 | S&F in replacement of AHU fan motor belt as per sample complete all as specified and directed |
| 101 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 25,191.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |