| 1 | Dismantling old damaged water tank and construction of Column |
| 2 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls. Dismantling RCC by manual / by using deploying machineries |
| 3 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls. Brick / Stone Masonry in cement mortar walls under 3m high |
| 4 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls. Dismantling Plain Cement Concrete |
| 5 | Earth work excavation and depositing on bank with initial lead of 10metres and lift of 2metres in all kinds of soil except mediumrock, dense medium rock and hard rock requiring blasting including refilling the sides of foundation with excavated earth in layers of 15cm thick, watering and consolidation and depositing the surplus earth with in the compound in places as shown by the departmental officers with initial lead and lift. cleaning,levelling the site etc,. complete complying with standard specifications.(TNBP No.20B) |
| 6 | Cement Concrete 1:4:8 (One Cement, Four crushed stone sand and Eight broken stone jelly) using 40mm size hard broken stone jelly excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete and as directed by the departmental officers. -Mixing by manual means |
| 7 | Providing steel centering for sides and soffits including supports and strutting upto 1:10/1:20 up to 3.29m height for plain surfaces such as RCC slabs, rectangular beams, Tee beams, bed blocks, Culvert body walls, deck slabs, retaining walls, staircase, Landing slab, landing beams, canopy etc., wood) joists of size 10cmx 6.5cm spaced at 90cm centre to centre and supported by casurina props of 10cm to 13cm dia spaced at 15cm c/c including cost of nails, ropes, all labour charges and incidental charges etc. complete complying with standard specification.(TNBP Spl. No.154 A) |
| 8 | Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 20mm size hard broken stone jelly for dummy columns,etc., excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete and as directed by the departmental officers. ( Dummy columns should be at least 1 metre height) -Mixing by manual means |
| 9 | Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers. |
| 10 | Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications |
| 11 | Plastering the surface of walls with Cement Mortar 1:4 (One cement and Four plastering sand), 20mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used , curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 12 | Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without inspiring strength and durability with about (5 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost ofreinforcement grill and fabricating charges, centering and shuttering and also including laying,vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 13 | Supplying, fabrication and placing in position of steel reinforcement using mild steel (or) ribbed tar steel rods, for all RCC works as per the design given by the departmental officers including cost of steel and binding wire and all labour charges for cutting, bending rods, tieing into grills, placing in position etc., complete as directed by the departmental officers.( TNBP No: 15886) |
| 14 | Painting two coats with approval cement paint over cement plastered wall surface. Ceiling and other new surface and including cost of all materials, all labour charges, brushes, cleaning, preparing the surfaces, scaffolding charges and curing charges etc. |
| 15 | Supply and delivery and fixingof HDPE tank as per IS 12701 /1996 including loading, unloading, transportation and labour chargesfor fixing of the GI pipes andspecials for pipe connection works including cutting, threadingand fixing charges etc.,2000litre |
| 16 | 40mm PVC pipe |
| 17 | 15mm PVC pipe |
| 18 | 40mm PVC Coupling |
| 19 | 40mm PVC Elbow |
| 20 | 15mm PVC Elbow |
| 21 | 15mm PVC TEE |
| 22 | 40mm PVC TEE |
| 23 | 40 x 15mm PVC Elbow |
| 24 | PVC Screw Down Tap Heavy Type 15mm dia Please Enable Macros to View BoQ information |