| 1 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 2 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge. |
| 3 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 4 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 5 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 6 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 7 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 8 | 110 mm diameter |
| 9 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (a) Coupler |
| 10 | 110mm |
| 11 | Single pushfit Coupler : (a) 110mm |
| 12 | Bend 87.5° (a) 110 mm bend |
| 13 | Shoe (Plain) (a) 110 mm bend |
| 14 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 15 | 110 mm |
| 16 | Grading roof for water proofing treatment with |
| 17 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 18 | Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 19 | Painting with water proof paint of approved make and quality on the roof of terrace of the building etc. all complete as per direction of Engineer in Charge. |
| 20 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 21 | 1:6 (1 cement: 6 coarse sand) |
| 22 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : |
| 23 | 1:4 (1 cement: 4 fine sand) |
| 24 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) finished with a top layer 6mm thick cement plaster 1:6 (1 cement: 6 fine sand). |
| 25 | Neat cement punning |
| 26 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 27 | Finishing walls with water proofing cement paint of required shade : |
| 28 | New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 30 | Two or more coats on new work. |
| 31 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. |
| 32 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 33 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 34 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 35 | Providing and fixing chicken wire mesh of approved make and quality on the surface of damaged platered, R.C.C. or brick work surfaces wherever required and fixing with nails, hooks before replastering or reconcreting the same etc. all complete as per the direction of Engineer-in-charge. |
| 36 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note :- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. Please Enable Macros to View BoQ information |