| 1 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and directed. |
| 3 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 4 | Material and labour for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 5 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surfaces in soft/loose soil complete all as specified and as directed. |
| 6 | Material and labour for cement concrete 1:2:4 type B-0 ( using 12.5mm graded stone aggregate ) as in drain channel, copings, flooring, sub base, etc complete all as specified and directed. |
| 7 | Material and labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundations filling and mass concrete complete all as specified and directed. |
| 8 | Material and labour for PCC 1:3:6 type C2 (using 40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and as directed. |
| 9 | Supply only water proofing compound. |
| 10 | Material and labour for Brick work with sub class 'B' old size built in CM 1 : 4, straight or curved on plan exc 6m mean radius on plan complete all as specified and directed. |
| 11 | Supply and fix steel windows with side hung shutters glazed shutter including both side openable (out side glazed window and inside fly proof window) including projecting type hinges with steel handle and steel peg stay complete with glazing bars and 12 mm square bar or round bar of approved design welded to steel window frame dovetailed or welded complete all as specified and directed . |
| 12 | Supply and fix Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 13 | Supply and fix powder coated two track aluminium sliding window with approved make of following extruded section of anodised glazed shutter as per Standard Engineering practices including all other accessories complete including 4.00 mm thick tinted glass panes (Include of 02 Nos tinted glass window shutter with alu frame with frame ), rubber beading window shutter with frame), , locking system (Include of 02 Nos window shutter) etc. complete all as specified and as directed. (Refer Jindal Cat M-2014 ) Aluminium sections : 'A' series (i) Shutter bottom & top :- 37.50 x 15 x 1.3 mm thick (20690)(ii) Shutter interlock :- 37.50 x 23 x 1.3 mm thick (20689)(iii) Shutter side (Handle) :- 37.50 x 23 x 1.3 mm thick (20689) (iv) Frame bottom :- 75 x 26 x 1 mm thick (20671) (v) Frame top and sides :- 75 x 26 x 1 mm thick (20672) |
| 14 | Supply and fix in repairs 1.25mm thick rolling shutter gear opeated type with level gear box and crank handle as specified including top cuver, anchoring rod, hasp and staple and one shop coat of primer erected in postion as indicated, complete all as specified and as directed |
| 15 | Repair and servicing of rolling shutters including taking down shutters and refixing in same opening of size exc 5 Sqm N.exc 10Sqm complete duly greasing, oiling, welding as required complete all as specified and directedNotes: Ball bearing, Saftey Lever Lock, hood, anchroing rod and any other accessories reqd to function the shutter inclusive in the rate. Nothing extra shall be admission on this account |
| 16 | Supply and fix for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured). |
| 17 | Supply and fix MS Channel,angle,plate or tee section cut to length including welding and bending angles as necessary as specified in shape and fabricated Fe-290 (Gde E-165) complete all as specified and as directed. |
| 18 | Fixing only chain link fencing and including line wire, any mesh, size and type to any type of standards, rails, straining bolts, etc. Including provision binding wire complete all specified and as directed. |
| 19 | Supply only chain link MS galvanized fencing of mesh size (75mmX75mmX3.15mm) of wire conforming to IS 2721 and complete all as specified complete all as specified and as directed. |
| 20 | Material and labour for round bar 10mm dia & over conforming to FE 290 (Gde-e-165) cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and bindingwith the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips cut to length bend to shape complete all as specified and as directed. |
| 21 | Supply and fix for 11 to 15 mm dia Mild steel, screw bold (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed ends to be fitted with washers and one hexagonal or square nuts n exc 5cm long complete all as specified and as directed. |
| 22 | Material and labour for machine cut kota stone slab flooring 18-20 mm thick over cement screed base 20 mm in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 23 | Material and labour for machine cut kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with including 10mm thick rendering in CM 1:4 etc set and jointed in neat cement slurry complete all as specified and as directed. |
| 24 | Material and labour for 80mm thick M-40 grade cement concrete coloured interlocking paver block any shape and size conformining to IS 15658-2006 with grey cement and pigment as approved complete all as specified and directed. |
| 25 | Material and labour heavy duty parking tiles of size 300mmX300mmX10 to 12 mm thick of approved make jointed in neat cement slurry, pointed in white or coloured cement to match colour of tiles, over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed. complete all as specified and as directed. |
| 26 | Material and labour for 100 mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate ) in sub base flooring etc complete all as specified and directed. |
| 27 | Material and labour for 25 mm thick PCC (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in floor finished rough to receive tiles complete all as specified and as directed. |
| 28 | Material and labour for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed. |
| 29 | Material and labour for 100mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate ) as.in floor finishing even and smooth with out using extra cement provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed |
| 30 | Material and labour for 15 mm thick rendering in cement mortar (1:4) fair faces of brick wall suerfaces, finished even and smooth without using extra cement complete. |
| 31 | Material and labour for 10mm thick rendering on other than fair faces of brick wall in CM 1:6 finished even and smooth with out using extra cement complete all as specified and directed. |
| 32 | Material and labour for rendering 15mm thick external in CM 1:4 on fair faces of brick/concrete surfaces finished even and smooth without using exta cement with using WPC @ 3% by the wt of cement. WPC shall be measured and paid seperately. |
| 33 | Material and labour for 5mm thick rendering on fair faces of brick or concrete surface in CM 1:3 finished even and smooth with out using extra cement complete all as specified and directed. |
| 34 | Material and labour for preparation of newly plastered surface of wall and applying three coats of white wash complete all as specified and directed |
| 35 | Material and labour for preparation New plastered surface of wall and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gMaterial and labouritre and UV resistance as per IS 15489:2004, Alkali & fungal resistance (Apex Ultima), dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. etc complete all as specified and as directed |
| 36 | Material and labour for preparing of newly plastered ceiling surface and applying three coats of white wash complete all as specified and directed. |
| 37 | Material and labour for preparation of old plastered surface of wall and a coats of white wash complete all as specified and directed |
| 38 | Material and labour for complete removal of existing treatment on wall surfaces by scrapping, washing & rubbing down including applying a layer 1 mm wall care (putty) for making the surface even & smooth etc complete all as specified. |
| 39 | Material and labour for preparation old surface of wall and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gMaterial and labouritre and UV resistance as per IS 15489:2004, Alkali & fungal resistance (Apex Ultima), dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. etc complete all as specified and as directed |
| 40 | Material and labour for preparing of newly plastered wall surface and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 41 | Material and labour for preparation of old painted surface of steel and iron by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots of any discription, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint, white or tinted complete all as specified and directed. |
| 42 | Material and labour for Preparation of new or previously un-treated steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed |
| 43 | Demolition of Stone slabs and tiles laid dry and dry or pointed of any description or thickness infloors, aprons etc complete all as specified and as directed. |
| 44 | Demolition of brick work built in cement mortar including all quoins, arches, pillar including coping etc. complete all as specified and as directed. |
| 45 | Taking down door chowkhat with shutter area n-exc 1.5 Sqm each(without taking off shutters from the frame) complete all as specified & directed. |
| 46 | Demolation of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 47 | Dismantling wrought iron or mild steel work of any description not otherwise provided,complete all as specified and as directed. |
| 48 | Taking down cement plaster of any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 49 | Dismantling old unserviceable barbed wire fixed in any type of post complete all as specified and directed Please Enable Macros to View BoQ information |