| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil, complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 4 | Excavating in post holes each n exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceedings 25cm watering and removing surplus soil to distance n exc 50 m and making good surface in hard/dense soils complete all as specified and directed. |
| 5 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed. |
| 6 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge. |
| 7 | Dismantling timber scantling 40 sqcm and over in section in any position framed work, complete all as specified and directed by Engr-in-Charge. |
| 8 | Dismantling unframed work in fillets, rails, posts, rafters, purlins etc under 40sqcm in section, complete all as specified and directed by Engr-in-Charge. |
| 9 | Dismantling boarding any description, fixed with any position with nails, complete all as specified and directed by Engr-in-Charge. |
| 10 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness including nanital pattern or similar pattern roof covering, complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for Hardcore of gauge n exc. 63 mm of broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 12 | M&L for cement concrete 1:4:8 type D2 (40 mm graged aggregate) as in foundation and filling mass concrete complete all as specified and directed by Engr-in-Charge. |
| 13 | M&L for PCC type C2, 1:3:6 (40mm graded aggregate) (M-10) as in foundation , filling and mass concrete and similar work , all as specified and directed. |
| 14 | M&L foer PCC type B2, 1:2:4 (40mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 15 | M&L for type C1, 1:3:6 (20mm graded aggregate) Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete complete all as specified and directed. |
| 16 | M&L for Type B1, 1:2:4 (20mm graded aggregate) Pre-cast cement concrete with hollow block masonry, exc. 10 cm in width and setting in CM 1:6, complete complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for RCC (Nominal mix) Type B1, 1:2:4 (20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L for RCC (Nominal mix) Type B1, 1:2:4 (20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L for RCC (Nominal mix) Type B1, 1:2:4 (20mm graded aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-in-Charge. |
| 20 | Use and waste flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engr-in-Charge. |
| 21 | Use and waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engr-in-Charge. |
| 22 | Use and waste Square, Rectangula or polygonal Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engr-in-Charge. |
| 23 | M&L for second class hard wood in scantling, clean sawn, timber framed and fixed, complete all as specified and directed by Engr-in-Charge. |
| 24 | S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints, complete all as specified and directed by Engr-in-Charge. |
| 25 | S&F 30mm thick 2nd class hardwood, Glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shuters as specified in SSR Part-I, Section 8, clause 8.24(a), fittted to chowkats, complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F 30mm thick 2nd class hardwood, Plain framed, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers fitted to chowkats, complete all as specified and directed by Engr-in-Charge. |
| 27 | Taking down chowkhats with shutters (without taking off shutters from the frame) not exc 1.5 sqm each, complete all as specified and directed by Engr-in-Charge. |
| 28 | Taking down chowkhats with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4.00 sqm each, complete all as specified and directed by Engr-in-Charge. |
| 29 | Taking down Wall/ceiling panelling and similar work complete all as specified and directed by Engr-in-Charge. |
| 30 | S&F PVC wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cemtn and fixing at sit eon PVC frame as per specifications and drawing, complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F 5mm thnick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed by Engr-in-Charge. |
| 32 | S&F 100mm aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engr-in-Charge. |
| 33 | S&F 200mm aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engr-in-Charge. |
| 34 | S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F 75mm butt hinges, mediam weight, cold rolled mild steel and fixed complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F 125mm butt hinges, mediam weight, cold rolled mild steel and fixed complete all as specified and directed by Engr-in-Charge. |
| 37 | S&F 100mm Aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge. |
| 38 | S&F 150mm Aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge. |
| 39 | S&F Mild steel work as Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engr-in-Charge. |
| 40 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed. |
| 41 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge. |
| 42 | S&F Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge. |
| 43 | S&F Rolled mild steel plate girder or single stanchions built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections conforming to Fe-290complete all as specified and directed. |
| 44 | S&F for S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161 1979 grade St.-240, complete all as specified and directed. |
| 45 | S&F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap,fixed with coach screws and washers in roof, walls etc with grade of zinc coating 275, complete all as specified and directed by Engr-in-Charge. |
| 46 | S&F 0.80mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as specified and directed by Engr-in-Charge. |
| 47 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws as specified, complete all as specified and directed. |
| 48 | S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws as specified, complete all as specified and directed. |
| 49 | M&L for 3mm thick cover fillet of standard hard board, 40mm wide and fixing with screws complete all as specified and directed by Engr-in-Charge. |
| 50 | M&L for 6mm thick Plywood, grade BWR, type BB, fixed with nails to timber frame work (05 No of ply), complete all as specified and directed by Engr-in-Charge. |
| 51 | M&L for 4mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work in ceiling, complete all as specified and directed by Engr-in-Charge. |
| 52 | M&L for 75mm thick PCC 1:3:6 type C2 (40mm graded aggregate) as in plinth protection complete all as specified and directed. |
| 53 | M&L for 75mm thick cement concrete 1:4:8 type D2 (40 mm graged aggregate) as in sub base or flooring complete all as specified and directed by Engr-in-Charge. |
| 54 | M&L for 100mm thick Cement concrete Type D2, 1:4:8 (40mm stone aggregate) as in floors or sub base, complete all as specified and directed. |
| 55 | M&L for 25mm thick PCC type B1 1:2:4 (20mm graded aggregate) as in floors, complete all as specified and directed. |
| 56 | M&L for 40mm thick PCC type B-0, 1:2:4 (12.5mm graded aggregate) as in floors, complete all as specified and directed. |
| 57 | M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed by Engr-in-Charge. |
| 58 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge. |
| 59 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick(square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge. |
| 60 | M&L for Virified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge. |
| 61 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 62 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 as backing coat complete all as specified and directed. |
| 63 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete complete all as specified and directed. |
| 64 | M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6, complete all as specified and directed. |
| 65 | Taking down Cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed. |
| 66 | M&L for preparation of new plastered surface of wall and applying two coat of cement base paint over a coat of alkali resistance priming paint complete all as specified and directed. |
| 67 | M&L for Preparation of new plastered surface of wall and applying two coat of OBD over a coat of Priming plastered and other surfaces with alkali resistant priming paint complete all as specified and directed. |
| 68 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 69 | M&L for preparation of old wooden surfaces of any description, over 10cm in width or girth,not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 70 | M&L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described over 10cm width or girth, and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge. |
| 71 | M&L for preparation of old steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 72 | M&L for preparation of new or previously untreated steel surfaces of any description, not otherwise described over 10cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide, zinc crome complete all as specified and directed by Engr-in-Charge. |
| 73 | Taking down of electrical switch board of any size/tube light/ceiling rose/holder and refixing after and over wall panelling complete all as specified and directed. |
| 74 | M/L for point wiring in casing caping with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl casing caping with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: - One light/fan point controlled by one No piano type switch 5 Amps single pole one way |
| 75 | One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board. |
| 76 | One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board. |
| 77 | All as per item No 1 above but one 3 pin socket out let 15/16 Amps with three Nos single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase, neutral & earth continuity conductor. |
| 78 | S&F Switch Piano Flush button single pole one way 5/6 Amp. |
| 79 | S&F Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal |
| 80 | S&F Switch socket combination 2 in 1, 6A flush type |
| 81 | S&F ceiling rose surface bakelite 65mmx50mm 10 watt three terminal. |
| 82 | S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door (Metallic) type including taking down old unserviceable MCB DB with MCBs. |
| 83 | S&F MCB SPN 32 Amps 240 volts 'C' series, 10 KA, 50 Hz. Make:- As approved Make of DB |
| 84 | S&F MCB SP 5 to 32 Amps 240 volts 'C' series, 10 KA, 50 Hz including connection in the DB and testing/commissioning. Make:- As approved Make of DB |
| 85 | Supply and fixing LED lights fitting 1x 18W, 4 feet, 220V,AC decorative box type with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 86 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete. |
| 87 | Supply and fixing LED light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 88 | Supply and laying or fixing or passing through pipeXLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade of size 16 sqmm 2 core complete including taking out old unserviceable cable all as specified and directed by Engineer in charge. |
| 89 | Supply and laying or fixing or passing through pipeXLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade of size 4 sqmm 2 core complete including taking out old unserviceable cable all as specified and directed by Engineer in charge. |
| 90 | S&F DWC Pipe 63/50mm size all as specified and directed by Engr-in-Charge. |
| 91 | Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduit grouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete including taking out old unserviceable earthing materials all as specified and as directed. Please Enable Macros to View BoQ information |