| 1 | Pre cleaning of wire ropes of all the 8 Nos Radial crest gates by wire brush,solvent for paper lubrication (2 Nos rope falls in each gates and length of each wire rope 10m x 25mm dia) work including cost of all required material,labour transportation & T&P etc & labour charges as per directed by Engineer-in-charge (4 Labours : 2 unskilled & Semi skilled 2 ). 1 gate =1 job X 8 Gate =8 Job |
| 2 | Providing and applying cardium compounds of approved quality to wire rope of hoist/gantry crans as per of annual maintenance including cost of all materials ,machinery,labour etc. complete. Required approx. 5 Kg of cardium compound per gate, Total 5 x 8 gates = 40 Kg |
| 3 | Pre cleaning of machinery drive hoist system,accessories (for proper greasing) in hand operated system gear train,shaft nipple,sproket chain,dial gauge,indicator,unit rope drum etc by screpacing of grese and cleaning of nible by wire including cost of all required material,labour transportation & T&P (4 Labours : 2 skilled, & 2 unskilled). 1 gate =1 job X 8 Gate = 8 Job |
| 4 | Providing and applying grease of approved quality to gate & hoist components,requiring grease as part of annual maintenance,using grease gun where ever necessary including cost of all materials machinery,labour,scaffolding etc complete. approx.12 Kg grease req. per gate, 8 gate X 12 Kg = 96 Kg |
| 5 | Providing and filling/replacing gear oil of approved quality up to the required gauge level for reduction gear unit of hoist/gantry crans including cost of materials,machinery, labour etc complete. 1 gate-1 No. gear unit, 8 gate 1X8 =8 gear unit, 2 litre req.-1 No. gear unit, 8 gear unit- 2 X 8 = 16.00 litre |
| 6 | Post Cleaning of radial crest gate after greasing ,oiling,compounding work i/e trunnion arm,supporting girders,seal surface etc waste material complete by solvent including cost of materials, labour and T&P (4 Labour: 1 Semiskilled, 3 unskilled). 1 gate =1 job X 8 Gate =8 Job |
| 7 | Providing, Fabrication, machining with straightening work of Guide Tee, Track, Sealing frame, Leaf frame or any part of gate's, complete as per drawing with testing ,including cost of all materials, with machinery, labour, tools and tackles cutting, aligning, welding, finishing, cleaning ,etc., applying one coat of zinc rich epoxy primer and two coats of cold applied coal tar epoxy paint, etc., complete as per specifications and approved drawings with all lead and lifts, including packing & forwarding, transportation charges for structural steel components and other materials. Rate of work with all materials |
| 8 | Oiling and greasing work of gate parts like Head stock parts Roller assembly,Operating Rod ,Sealing Frame ,Guide Tee. For Gate size upto 1mX1m |
| 9 | Supply and fixing Led tube rod comprising of LED tube with non integral/integral driver,upto 6500K color temp having 40000 burning hrs life with minimum @L70, system lumen output should be minimum with system efficacy>100lm/Watt.LED driverPF>0.95 &THD. Tube light LED 1X18 Watt, Integral i/c batten aluminium body, PC diffuser. |
| 10 | LED flood light Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF>0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 30 Watt, color temp 3000-6500k as required. |
| 11 | Street light with high power LED systemSupply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additionalunique peanut lens on each LED, system lumens output withefficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. 40 Watt to 48Watt, color temp 3000-6500k as required. Please Enable Macros to View BoQ information |