| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 2 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose complete all as specified and directed by Engr-in-Charge. |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 4 | Excavating in trenches, exc 1.5 m wide and not exc 3.00m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge. |
| 5 | Excavating in trenches, exc 3.00 m wide and not exc 4.50m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge. |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 7 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 8 | M&L for Loose filling with aggregates of gauge 80 to 150mm of broken bricks in soakage pits, soakage wells complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for Hardcore of broken stone or boldours of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engr-in-Charge. |
| 10 | M&L for cement concrete 1:4:8 type D2 (40 mm graged aggregate) as in foundation and filling mass concrete complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for PCC Type B1, 1:2:4 (20mm graded aggregate) walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for PCC type B1, 1:2:4 (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed by Engr-in-Charge. |
| 13 | M&L for Type B1, 1:2:4 (20mm graded aggregate) Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar mortar 1:6, complete complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L for precast cement concrete type C1, 1:3:6 (20mm graded aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 15 | M&L for Type C1, 1:3:6 (20mm graded aggregate) precast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in mortar 1:6, complete, in walls complete all as specified and directed by Engr-in-Charge. |
| 16 | M&L for RCC (Nominal mix) Type B1, 1:2:4 (20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for RCC (nominal mix) type B1, 1:2:4 (20mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed. |
| 18 | M&L for RCC (Nominal mix) Type B1, 1:2:4 (20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L for RCC (Nominal mix) Type B1, 1:2:4 (20mm graded aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc.complete all as specified and directed by Engr-in-Charge. |
| 21 | M&L for Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 22 | Use and waste flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engr-in-Charge. |
| 23 | Use & waste formwork to faces of walls, retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses, etc vertical or to batter, complete all as specified and directed by Engr-in-Charge. |
| 24 | Use & waste curved Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)complete all as specified and directed by Engr-in-Charge. |
| 25 | Use & waste flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 26 | Use & waste curved formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands inwalls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening, the formwork soffit only shall be paid for under item 07010) complete all as specified and directed by Engr-in-Charge. |
| 27 | Use and waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engr-in-Charge. |
| 28 | Use and waste Square, Rectangula or polygonal Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engr-in-Charge. |
| 29 | M&L for second class hard wood in scantling, clean sawn, timber framed and fixed, complete all as specified and directed by Engr-in-Charge. |
| 30 | S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints, complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F 30mm thick 2nd class hardwood, Glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shuters as specified in SSR Part-I, Section 8, clause 8.24(a), fittted to chowkats, complete all as specified and directed by Engr-in-Charge. |
| 32 | S&F 30mm thick 2nd class hardwood, Plain framed, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers fitted to chowkats, complete all as specified and directed by Engr-in-Charge. |
| 33 | SS&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and directed by Engr-in-Charge. |
| 34 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F 100mm aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F 200mm aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engr-in-Charge. |
| 37 | S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed by Engr-in-Charge. |
| 38 | S&F 125mm butt hinges, mediam weight, cold rolled mild steel and fixed complete all as specified and directed by Engr-in-Charge. |
| 39 | S&F 75mm butt hinges, mediam weight, cold rolled mild steel and fixed complete all as specified and directed by Engr-in-Charge. |
| 40 | S&F 100mm Aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge. |
| 41 | S&F 150mm Aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge. |
| 42 | S&F Brass Hat pegs, solid body, 125mm to 175 mm complete all as specified and directed. |
| 43 | S&F Brass Hat and coat hooks, solid body, 175mm to 250 mm complete all as specified and directed. |
| 44 | S&F Aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 45 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge. |
| 46 | S&F Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge. |
| 47 | S&F Rolled mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 48 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 49 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 50 | M&L for 3mm thick cover fillet of standard hard board, 40mm wide and fixing with screws complete all as specified and directed by Engr-in-Charge. |
| 51 | M&L for 4mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work in ceiling, complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F 18/19mm thick Prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination, fixed with screws to timber frame workcomplete all as specified and directed. |
| 53 | M&L for 75mm thick PCC 1:3:6 type C2 (40mm graded aggregate) as in plinth protection complete all as specified and directed. |
| 54 | M&L for 100mm thick Cement concrete type D2, 1:4:8 (40mm graded aggregate) as in sub base or in floors complete all as specified and directed by Engr-in-Charge. |
| 55 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge. |
| 56 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge. |
| 57 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and directed. |
| 58 | M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6, complete all as specified and directed. |
| 59 | M&L for Preparation of new plastered surface of wall and applying two coat of OBD over a coat of Priming plastered and other surfaces with alkali resistant priming paint complete all as specified and directed. |
| 60 | M&L for Preparation of new plastered surface of wall and applying two coat of cement base paint over a coat of priming plastered and other surfaces with alkali resistant priming paint complete all as specified and directed. |
| 61 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 62 | M&L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described over 10cm width or girth, and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge. |
| 63 | M&L for preparation of new steel urfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc crome complete all as specified and directed. |
| 64 | S&F 25mm dia 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain &brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. |
| 65 | S&F 32mm dia 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain &brass threaded polypropylene random fittings fixed complete to walls, ceilings or infloors etc. complete all as specified and directed. |
| 66 | S&F 250Ltr capacity Rotational moulded polyethylene water storagetanks (cylindrical verticalwith closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as specified and directed. |
| 67 | S&F 500Ltr capacity Rotational moulded polyethylene water storagetanks (cylindrical verticalwith closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as specified and directed. |
| 68 | S&F 15mm dia fancy type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 69 | S&F 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 70 | S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 71 | S&F Waste coupling of PTMT 32 mm dia (half or full threaded) (Minimum weight 32mm - 45gms/40mm-60 gms) complete all as specified and directed. |
| 72 | S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed. |
| 73 | S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 74 | S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floorscomplete all as specified and directed. |
| 75 | S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floorscomplete all as specified and directed. |
| 76 | S&F 110mm PVC (SWR) bends any radius complete all as specified and directed. |
| 77 | S&F vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including provn of lime concrete bedding, including Flush pipes to squatt pattern closet including all joints and making good to the floor, complete all as specified and directed |
| 78 | S&F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including bracket High or low level fluslhing cistern (exclusive of brackets), and connections to pipes and fixing of chain and pull, or lever, if any complete all as specified and directed. |
| 79 | S&F Vitreous China Urinal, full stall type, white (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe), complete all as specified and directed. |
| 80 | S&F Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste, chain and plugs but including brackets complete all as specified and directed. |
| 81 | S&F 15mm dia Angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle and fixedcomplete all as specified and directed. |
| 82 | S&F 32mm dia waste pipe for WHB/Sink complete all as specified and directed. |
| 83 | S&F high quality large rectangular mirror of size (1.20mx 0.80m) with steel frame around the glass, complete all as specified and directed. |
| 84 | S&F Stainless steel soap holder wall mount complete all as specified and directed. |
| 85 | S&F tank connector with all fitting suitable to 32mm dia PPR pipe complete all as specified and directed. |
| 86 | SS&F 20mm dia mild steel chromium plated curtain rod including fixing clips and brackets complete all as specified and directed. |
| 87 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 88 | M/L for point wiring in casing caping with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl casing caping with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: One light/fan point controlled by one No piano type switch 5 Amps single pole one way |
| 89 | One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board. |
| 90 | One socket outlet 5/3 pin 6 AMPS controlled by one switch on the independent board. |
| 91 | All as per item No 88 above but one 3 pin socket out let 15/16 Amps with three Nos single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase, neutral & earth continuity conductor. |
| 92 | S&F Switch Piano Flush button single pole one way 5/6 Amp. |
| 93 | S&F Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal |
| 94 | S&F Switch socket combination 2 in 1, 6A Amp flush type |
| 95 | S&F ceiling rose surface bakelite 65mmx50mm 100watt three terminal. |
| 96 | S&F sheet metal enclosure double door for MCB DB single pole and neutral 12 way with 200 Amps rated bus bar 240 volts double door (Metallic) type including taking down old unserviceable MCB DB with MCBs. |
| 97 | S&F MCB SPN 32 Amps 240 volts 'C' series, 10 KA, 50 Hz. Make:- As approved Make of DB |
| 98 | S&F MCB SP 5 to 32 Amps 240 volts 'C' series, 10 KA, 50 Hz including connection in the DB and testing/commissioning. Make:- As approved Make of DB |
| 99 | Supply and fixing LED lights fitting 1x 18W, 4 feet, 220V,AC decorative box type with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 100 | Supply and fixing LED light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 101 | S&F sheet metal enclosure double door for MCB DB single pole and neutral 4 way with 200 Amps rated bus bar 240 volts double door (Metallic) type including taking down old unserviceable MCB DB with MCBs. |
| 102 | Supply and fix exhaust fan made of sturdy engineering plastic complete with shutter ,voltage 230 V ,50Hz,RPM 1200 copper winding of sweep 250 mm compete all as specified and as directed. |
| 103 | Supply and laying or fixing or passing through pipeXLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade of size 10 sqmm 2 core complete all as specified and directed by Engineer in charge. |
| 104 | Supply and laying or fixing or passing through pipeXLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade of size 4 sqmm 2 core complete all as specified and directed by Engineer in charge. |
| 105 | S&F DWC Pipe 63/50mm size all as specified and directed by Engr-in-Charge. |
| 106 | Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduit grouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completionincluding taking out old unserviceable earthing materials all as specified and as directed. |
| 107 | S & F 3- layer PP-R Polypropylene random copolymer) of size 25 mm outer dia concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches/wall with all connected fittings as required at site all as directed and specified. |
| 108 | S.&.F PP-R Gate valves (brass insert) 25 mm dia as per requirement of the site. Please Enable Macros to View BoQ information |