| 1 | Schedule \\"A\\" Part-I to Schedule \\"A\\" Part \\"XI\\"Note: Schedule \\"A\\" Part-I to Schedule \\"A\\" Part \\"XI\\" are prepriced by MES,Bidders shall enter their lumpsum amount in green field under colum 8 only |
| 2 | Lumpsum price worked out by the contractor for \\"Buildings & Structures\\" as listed in Schedule \\" Part-I \\" on serial page no 29 |
| 3 | Lumpsum price worked out by the contractor for \\"EARTHWORK , SITE CLEARANCE AND SITE DEVELOPMENT\\" as listed in Schedule \\" Part-II \\" on serial page no 30 |
| 4 | Lumpsum price worked out by the contractor for \\"INTERNAL WATER SUPPLY\\" as listed in Schedule \\" Part-III \\" on serial page no 32 |
| 5 | Lumpsum price worked out by the contractor for \\"INTERNAL ELECTRIC SUPPLY \\" as listed in Schedule \\" Part-IV\\" on serial page no 37 |
| 6 | Lumpsum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY\\" as listed in Schedule \\" Part-V \\" on serial page no 38 |
| 7 | Lumpsum price worked out by the contractor for \\"EXTERNAL ELECTRIC SUPPLY, P\\" as listed in Schedule \\" Part-VI \\" on serial page no 40 |
| 8 | Lumpsum price worked out by the contractor for \\"SEWAGE DISPOSAL\\" as listed in Schedule \\" Part-VII \\" on serial page no 42 |
| 9 | Lumpsum price worked out by the contractor for \\"AREA DRAINAGE\\" as listed in Schedule \\" Part-VIII \\" on serial page no 43 |
| 10 | Lumpsum price worked out by the contractor for ROAD/PATH/HARDSTANDING/CULVERT\\" as listed in Schedule \\" Part-IX \\" on serial page no 45 |
| 11 | Lumpsum price worked out by the contractor for \\"FIRE FIGHTING\\" as listed in Schedule \\" Part-X \\" on serial page no 49 |
| 12 | Lumpsum price worked out by the contractor for \\"ARBORICULTURE\\" as listed in Schedule \\" Part-XI \\" on serial page no 51 |
| 13 | Lumpsum price worked out by the contractor for \\"TV AND LAN CONDUIT\\" as listed in Schedule \\" Part-XII \\" on serial page no 52 |
| 14 | Lumpsum price worked out by the contractor for \\"PILE FOUNDATION\\" as listed in Schedule \\" Part-XIII \\" on serial page no53 |
| 15 | Schedule \\"A\\" Part-XIV [Miscellaneous Items) |
| 16 | EARTHWORK,SITE CLEARANCE AND SITE DEVELOPMENT |
| 17 | Supply of Locally available approved earth with fines content ( 75 micron passing through 20%), spreading, leveling in layers n exc. 25 cm thick; watering, ramming/rolling with mechanical rollers not less than 8T. compaction shall be done at OMC to a specified percentage of standard proctor density n. less than 95%. NOTE:(a) Locally available approved earth required from the item shall be supplied by contractor from out side MOD land at his own arrangement. (b) All cost of procurement or earth including cost of transportation, royalties, taxes etc shall be deemed to be included in the unit rate quoted by the contractor. (c) The earth supplied shall be used for filling. Finished embankment/ traverse of filled earth consolidated/ compacted shall be considered for measurement purpose and volume shall be calculated based on these measurements. Also a 5% (five percent) deduction from calculated volume shall be made in terms of clause 3.6 of MES Sch Part-II to allow for increase in bulk. |
| 18 | PILE FOUNDATION |
| 19 | Carrying out initial load testing on 500mm dia, 16m deep piles of following test all as per IS complete all as specified and as directed including necessary anchoring and support piles of suitable load/size to be casted as required |
| 20 | (a) Compression Test |
| 21 | (b) Pull out Test |
| 22 | (c) Lateral Test |
| 23 | Carrying out routine load testing on 500mm dia, 16m deep piles of following test all as per IS complete all as specified and as directed including necessary anchoring and support piles of suitable load/size to be casted as required |
| 24 | (a) Compression Test |
| 25 | (b) Pull out Test |
| 26 | (c) Lateral Test |
| 27 | Carrying out strain integrity load testing on cast in situ piles including analysing the results as per ASTM D5882 and as directed by Engr-in-Charge |
| 28 | Boring for Bored cast in situ piles 25 metres in soil and getting out and disposal of spoil to a distance 50 metres using DMC method (Directmud circulation) 500 mm dia complete all s specified and as and as directed |
| 29 | INTERNAL WATER SUPPLY |
| 30 | S & F two way bib cock with wall flange quarter turn (Low-flow) 16 mm dia.complete all as specified and directed by Engineer-in-Charge |
| 31 | S& F Pillar Cock (Low-flow) 16 mm dia fixing complete all as specified and directed by Engineer-in-Charge . |
| 32 | S & F Hand shower (Health faucet) with 1.20 meter long easy ss chorme plated hose flex tube in chrome finish and wall hook with NRV (Back flow preventer) complete all as specified and directed by Engineer-in-Charge |
| 33 | S & F Angular Stop Cock 15 mm bore of pipe (20 mm outer dia) with Wall Flange chromium plated Stop valvescomplete all as specified & directed . |
| 34 | FIRE FIGHTING |
| 35 | Supply and fix of fire extinguiser ISI marked CO2 type Fire Extinguisher 3.0 KG capacity conforming to IS : 15683 :2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224 , high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, , suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 138 all as specified and as directed. |
| 36 | Supply and fix of stored pressure fire extinguiser ISI marked powder type Fire Extinguisher 4 KG capacity suitable for Class \\"A\\", \\"B\\", \\"C\\" Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammoniumphosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 1A & 13B all as specified and as directed. |
| 37 | Supply and fix of Fire Extinguisher of lSl Marked Water Stored Pressure type Fire Extinguisher 9 Itrs. capacity consisting of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage with internal discharge tube, discharge nozzle suspension bracket, conforming to lS: 15683:2006 (old IS : 6234) duly charged wiih purged water and pressurized with Nitrogen Gas, suitable for operating between + 50 degree Centigrade to +55 degree Centigrade, Fire Rating Class - 3A all as specified and as directed. |
| 38 | Supply and fix of Fire Extinguisher Mechanical Foam type ISI Marked Foam (AFFF) type Fire Extinguisher 9 ltrs capacity fitted with Forged Brass squeeze lever discharge valve, conforming to IS : 15683 :2006, complete with initial refill consisting of ISI Marked CO gas cartridge of 60 gms capacity conforming to IS 4947 and ISI Marked AFFF conforming to IS : 4989, suitable for operating between + 50 degree centrigrade , Fire Rating Class - 3A & 34B all as specified and as directed. |
| 39 | Supply and fix of stored pressure fire extinguiser ISI marked powder type Fire Extinguisher 9 KG capacity suitable for Class \\"A\\", \\"B\\", \\"C\\" Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammoniumphosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 1A & 13B all as specified and as directed. |
| 40 | S&F auto-illuminated (glow-in-dark) sign board with red colour background with appropriate symbol, made up of acrylic sheet for fire escape in minimum 15 cm x 30 cm size to be pasted on wall with high quality adhesive or to be hanged with s.s. hook-chain system all as specified and as directed. |
| 41 | Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made CPRI approved free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 2 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of copper bus bar of 200 Amps capacity each and supply and fixing the following :-Incoming(a) MCCB 63A, 4 pole 25 KA-1 No (b) Ammeter 0-40 Amps 96 mm square digital type. (c ) Voltmeter --500V -01 No digital type 96 mm square (d) 01 set of 3 nos LED indication lamp. Outgoing :-(a) Fully automatic star delta strater complete with contactor, relay etc of capacity 15 HP- 01 No. |
| 42 | M & L 2 way fire brigade inlet connection 63 mm dia with 1.5 mtr stand post ncluding all fittings arrangement complete all as specified and as directed |
| 43 | FENCING/COMPOUND WALL |
| 44 | S&F of Concertina coil 610 mm dia punched barbed wire tape (SRPBT) aluminium base helix coil including necessary GI fixing clip with additional primer treatment epoxy/polyurethane & final paint top coat of Caulified green shade by Hot dipping process complete all as specified and as directed. (i) Weight of each coil ; 8.00 to 8.50 Kg (ii) Coverage per coil: 6.00 to 6.50 RM. Note : Running length of the wall shall be measured for payment purpose |
| 45 | M&L for AAC block masonry in cement mortar 1:4 straight or curved on plan exc 6 mtr mean radius complete all as specified and as directed. |
| 46 | M & L for On site LLDPE Septic tank design for 25 Users to carry sewage and sullage water, excavation in type of soil, pcc 1;4:8 below foundation, vent shaft connection etc complete all as specified and as directed. |
| 47 | INTERNAL ELECTRIC SUPPLY |
| 48 | Supply and fixing Batten lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 49 | Supply and fixing LED light fitting with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 50 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 51 | S & F Metal flush box 8 module conforming to IS complete all as specified and as directed. |
| 52 | Supply and fixing 6 Module power unit pvc box with Ac motor starter 2 modular with red and green switch, 2 module socket, double pole MCB complete with connection testing and commissioning. complete all as specified and directed. |
| 53 | S&F sheet metal enclosure MCB distribution board Vertical Triple pole and neutral 6 way sheet metal enclosures Double door complete all as specified and directed |
| 54 | EXTERNAL ELECTRIC SUPPLY |
| 55 | Supply install commissioning and testing floor mounted outdoor cubical type LT Feeder Pillar Box (CPRI tested) fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, Copper bus bar 1.5 times incomer capacity fixed on porcelain insulator with internal complete control wiring with suitable size of Aluminium strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with Aluminium lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint incl. necessary PCC (1 : 3 : 6) type C2 as in foundation all as directed, comprising of the following : : FOR IINCOMER :- (i) 160 Amp Microprocessor MCCB 4 pole 36 KA - 01 No. OUTGOING :- (i) 125 Amp MCCB 4 pole 36 KA - 02 No.(ii) 63 Amp MCCB TPN 16 KA pole - 02 No(iii) 6-32Amp MCB SPN pole - 02 No(iv) Cooper Bus bar of 1.5 times of incomer Amp 4 way. (v) Digital type Ameter , range 0 to 400 Amp with slector switch and CT -01No(vi) Digital type Volt meter, range 0 to 500 Volt with slector switch and PT-01No (vii) Indicator lamp RYB-01 set (viii) Digital Timer - 01 Nos(ix) MNX Contactor - 01 Nos |
| 56 | Supply and fixing minimum 12 watt, 230 V AC LED bollard light fitting of Sturdy IP 65 LED Bollard with excellent/glare free soft light output through its PMMA window ensuring maximum illumination aspect in surrounding with aluminium die cast material for fixture along with anti-ageing spray treatment on housing for longer life including PCC foundation, plastrering,panting, white wash complete all as specified and directed. |
| 57 | TV AND LAN CONDUIT |
| 58 | Supply & Fixing socket outlet RJ 11 modular type ISI marked complete all as specified. |
| 59 | Supply & Fixing socket outlet RJ 45 modular type ISI marked complete all as specified. |
| 60 | ARBORICULTURE |
| 61 | Supllying and stacking of good earth (fresh garden soil) at site including royality and carring withany lead complete all as specified |
| 62 | Supllying and stacking of frameyard manure at site including royality and carring with any lead complete all as specified and as directed. |
| 63 | M&L for planting and developing lawn grass (phospolen) including following:(a) Preparing of soil base by excavation / ploughing and loosening of ground upto 15cm and removing unwanted material, grass stone etc to a distance exceeding 50m but not exceeding 250m(b) Mixing good earth (fresh garden soil) & farm yard manure throughly in 2:1 proportion and filling excavate area to a height of 15cm and levelling including suitable quantity of oil cake, bone dust, anti termite powder completely.(c) Watering on previous night and planting required variety of lawn grass and maintaining for a minimum period of 180 days or till formation of well established lawn grass whichever is later blanket to the satisfaction of Engr-in-Charge by watering, weeding, clipping and rolling etc complete. |
| 64 | M&L for planting and developing different type hedge plants naming alternanthera, codiaeum, maranta etc including following:(a) Preparing of soil base by excavation / ploughing and loosening of ground upto 15cm and removing unwanted material, grass stone etc to a distance exceeding 50m but not exceeding 250m(b) Mixing good earth (fresh garden soil) & farm yard manure throughly in 2:1 proportion and filling excavate area to a height of 15cm and levelling including suitable quantity of oil cake, bone dust, anti termite powder completely.(c) Watering on previous night and planting required variety of lawn grass and maintaining for a minimum period of 180 days or till formation of well established lawn grass whichever is later blanket to the satisfaction of Engr-in-Charge by watering, weeding, clipping and rolling etc complete. |
| 65 | M&L for planting night and planting Raphis/Pritcharadia Palm for area beautification or landscape including following(a) Digging hole of size 600mm dia x 600 depth, removing and conveying excavated soil to a distance exceeding 50m and n exc 250m.(b) Filling the hole with fresh garden soil and fram yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-in-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed. |
| 66 | M&L for planting of Orange / Crape/ Tangar jasmine including following(a) Digging hole of size 600mm dia x 600 depth, removing and conveying excavated soil to a distance exceeding 50m and n exc 250m.(b) Filling the hole with fresh garden soil and fram yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-in-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed. |
| 67 | M&L for planting different colours of bogun baliy including following(a) Digging hole of size 600mm dia x 600 depth, removing and conveying excavated soil to a distance exceeding 50m and n exc 250m.(b) Filling the hole with fresh garden soil and fram yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-in-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed. |
| 68 | M&L for planting different type coconut (Ganga bandhan) including following(a) Digging hole of size 600mm dia x 600 depth, removing and conveying excavated soil to a distance exceeding 50m and n exc 250m.(b) Filling the hole with fresh garden soil and fram yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-in-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed. |
| 69 | M&L for planting different colours of oleander (Hind-Kaner, Bengali Kabirei) of 2 feet height including following(a) Digging hole of size 600mm dia x 600 depth, removing and conveying excavated soil to a distance exceeding 50m and n exc 250m.(b) Filling the hole with fresh garden soil and fram yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-in-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed. |
| 70 | M&L for planting and developing pyranmid type Ashoka tree (Bengali-Deodar)/different type Champa tree of 2 feet height including following (a) Digging hole of size 600mm dia x 600 depth, removing and conveying excavated soil to a distance exceeding 50m and n exc 250m.(b) Filling the hole with fresh garden soil and fram yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-in-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed. |
| 71 | M&L for planting different type Araceae (Philodendron/ Alocasia) Ficus star light including following (a) Digging hole of size 600mm dia x 600 depth, removing and conveying excavated soil to a distance exceeding 50m and n exc 250m.(b) Filling the hole with fresh garden soil and fram yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-in-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed. |
| 72 | M&L for planting different type Mango/Jamun including following(a) Digging hole of size 600mm dia x 600 depth, removing and conveying excavated soil to a distance exceeding 50m and n exc 250m.(b) Filling the hole with fresh garden soil and fram yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-in-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed. |
| 73 | M&L for planting different type different colours of Russeia including following(a) Digging hole of size 600mm dia x 600 depth, removing and conveying excavated soil to a distance exceeding 50m and n exc 250m.(b) Filling the hole with fresh garden soil and fram yard manure in 2:1 proportion upto a height of 0.6m levelling including suitable quantity of oil cake, bone dust, anti termite powder and watering as specified and approved by Engr-in-Charge and maintaining for a minimum period of 180 days or till formation of well established plants whichever is later complete all as directed. |
| 74 | Supply and fix Pumping sets, centrifugal, electric driven, Single Phase 2 HP inclusive of starter and PCC foundation. with all fittings and fixtures complete all as specified and directed . Please Enable Macros to View BoQ information |