| 7 | INDOOR SUPPLY:Supply of Centralized Electronic Interlocking (Hot Standby) with dual VDU of 55\\" with Signalling functions as per RDSO Specification No. RDSO/SPN/192/2019 Ver.2.0 and to suit the signalling plan and to suit the signalling plan of stations.Scope of supply against this item includes all the indoor equipments necessary for successful functioning of centralised EI system, mainly consisting of but not limited to followings conforming to attached Technical specifications .1. Microprocessor equipment.2. I/O cards with card cage and motherboard.3. Power supply cards.4. All types of connectors and couplers as required.5. Industrial grade Dual VDU of 55\\" .6. Industrial grade PC & monitor of 55\\"7. maintenance VDU of 55\\" console with Laser printer at panel building.8. All types of relays required for interfacing.9. ECRs suitable for LED signal lamps.10. DC-DC convertors (input voltage 110 V DC and output voltage as required)11. All types of indoor wires as required.12. All types of indoor terminals and fuses as required except terminals for main CTR. |
| 8 | 13. Racks for mounting EI equipments and interfacing relays.14. Fixtures, mounting arrangements, Ladders for wire run and other accessories as required.15. Softwares used for designing, configuration, maintenance, data logging and fault diagnosis of EI system. 16. Protective devices like lightning protectors for DC and AC supplies, isolator/convertor for serial communication etc. 17. Documents and manuals as per RDSO/SPN/192/2019 Ver.2.0 in three set18. Any other item contractor feels neccessary as per their sysyem.19.Completion plan of stations.20. Work place for EI is also provided by the contactorNote: 1. All the materials, submitted by the bidder as above and are neccessary for successful commissioning of system, shall be supplied by the contractor without any extra cost. Variation in Bits and variation in number of routes upto (+) 10% shall have no cost bearing.2. For further variation (above 10%) of routes, cost will be recovered on prorata basis for % of routes increased.3) Supply of all spares to the extent of 10% of that supplied against EI item subject to minimum of one, for the cards/modules,connectors /couplers, fuses & relays. used in the EI system. Item-wise details of spares to be supplied with unit rates should be listed out by the tenderer along with offer. |
| 9 | Supply of Laptop based work station for data inputs & configuration, simulation and functional testing, diagnostics, trouble shooting and commissioning of EI system, complete with necessary softwares preloaded. as per specifications mentioned in TS. |
| 10 | Tool kits and Measuring Instruments for Technicians /Junior Engineers for testing & maintenance and repair at site as specified by Original Equipment Manufacturer of EI. * Above items includes suitable cabinet for storing tools to ensure longer life. |
| 11 | Supply of Hard & soft copy (6 copies as built ) of following indoor drawings for RITES/ Rly approval including one copy on good quality 7.5 micron polyster film: this includes expenses for checking/rechechecking/ obtaing appovals from Railways /RITES .The also includes supply of two sets of drawings for checking, approval and corrections thereon as suggested by RITES/Rly) & threater supply of 2 copies for testing copy & 2 copies as costruction copy.RITES shall make available Schematic SIP.Contractor to Prepare and submit SIP's and other Misc Drgs as per concerened Rly practice and get its approval from railways,if requiered- (i) Signalling Interlocking Plan (as per Rly practice)(ii) Selection table, (iii) Vital & non-vital I/O Bit Chart, (iv) EI configuration diagram, Equipment layout plan, Relay disposition chart. (v) Front plate diagram of control/indication panel. (vi) Application logic (vii) Interface circuit with contact analysis. (viii) Equivalent circuit of application logic. (ix) Prepration & supply of SWRD (station Working Rule Diagram). (x) Prepration & supply of station working Rule. |
| 12 | Main cable termination rack complete assembly with hylam sheet , screws, nuts & bolts, scaffolding ladders for cable wires alongwith mounting arrangements etc. as per Drg No..NR/S&T/project/13/2015..Fuse block shall be suitable for round head type voltage fuses rating:2A/4A/16A |
| 13 | Fuse block made of PBT as per IRS:S-75/2006 (Rev-2) & RDSO Drg.No.SA-23748 Alt.4 and Spec.No.IRS S 78/92 (Amdt-2) or latest amendment. Fuse block shall be suitable for round head type voltage fuses rating:2A/4A/16A |
| 14 | Non deteriorating type fuses as per IRS-S-78/92 with latest amendment. Rating 2Amps-65%, 4Amps-25%, 16Amps-10%.Fuse shall be suitable for round head type voltage fuses rating:2A/4A/16A |
| 15 | ARA terminal 6 way, made of PBT as per drawing No. 23756 Alt3 confirming to RDSO specn. No.IRS-S-75/2006 (Rev.2 or latest) with latest amendment |
| 16 | ARA terminal (1 way) made of PBT as per drg.no.23746 & specn. No.IRS-S-75/2006 (Rev.2 or latest) with disconnection link as per Drg.SA-23746 Or 23745(Alt-5). |
| 17 | Supply of 4 conductor Knife disconnect terminal block i.e. Wago confirming to Specification No. RDSO/SPN/189/2004, Ver.3 or latest. Connection method: Spring-cage connection, Cross section: 0.2 mm² - 2.5 mm², Nominal current: 16 A, Nominal voltage: 400 V, Color: as per instruction of site engineer. Flammability rating according to UL 94-V0, |
| 18 | Supply of End and Intermediate Plate 2.5mm/0.098 in Thick Wago or similar as per RDSO/SPN/189/2004 Ver.2.0 or latest. |
| 19 | Supply of Steel carrier Rail 35x7.5mm/0.039in thick unslotted, yellow with Chrome Wago or similar as per RDSO/SPN/189/ 2004 Ver.2.0 or latest. |
| 20 | Supply of screw less end stop 10mm/0.394 in wide carrier rail DIN 35 Grey Wago or similar as per RDSO/SPN/189/2004 Ver.2.0 or latest. |
| 21 | SMPS based Integrated Power Supply as per RDSO Specification No. RDSO/SPN/165/2012 with latest ammendment alongwith LMLA Battery Bank of 300AH & Battery rack (Configuration based on RDSO dwg. no. SDO/IPS/PI-6L/RE/004 and site specific load requirement, shall be put up to RITES with load calulation sheet and approved by employer/consultant before supply) |
| 22 | DG set 15 KVA, 230 V AC single phase with two wall mounting control panels (one main and one subsidisry for remote operation) to start generatoe by push button battery operated- 15KVA to IRS-S-69/86 along with sound proof enclosure for DG set as per latest guidelines of Central pollution control board of india. This includes a) Supply of batteries 12v, 200AH 1 No. with each DG set for self starting and Iron clad siemens or sony single phase (2 way ON-OFF-ON) changeover switch 63 Apms). Suitable Battery cahrger for charging this battery c) 60 liter diesel tank |
| 23 | Supply of Automatic change-over unit for change-over between three power supply sources of 63 A/230 volts, single phase with provision of manual bypass arrangement. Drawing shall be got approved by Engineer Incharge. |
| 24 | Supply & installation of maintenance free single earthing for IPS/DAC Equipment. All the materials required shall be supplied by the contractor including cadmium bronze wire rope for connection between earth electrode and equipment box). |
| 25 | Supply and installation of Earth leakage Detector for monitoring different AC and DC supplies including all accessories as per Spn RDSO/SPN/256/2002 or latest and stipulations of tender doccuments (ELD having 12 channel type). |
| 26 | Supply of Data logger system for Railway S&T Installations with 512 Digital and 32 Analog inputs as per Specification No. IRS:S-99/2006 (Amdt-3) or latest with power supply arrangement (batteries and charger), fault diagnostic PC & software for failure analysis and E1/64 Kbps Voice Channel/Optical modem card. It includes: - CMU (i3 or latest with 256 GB SSD or higher, 8 GB RAM), with UPS (minimum 6 hrs. battery backup) and printer- 01 No. Magnetic door lock coil to be supplied along with equipment. Note: i) The contractor is required to confirm the required modem to meet the site requirement before placing an order to any RDSO approved OEM from Engineer in charge.ii) The inspection of E1/Optical Modem shall be done by consigne |
| 27 | Supply, installation, testing and commissioning of SSI Protocol Card of Data logger Specification No. IRS:S 99/2006 (Amdt-3) or latest as per EI make |
| 28 | Supply and installation of Crank handle Box 1000 x 250 x 150mm made of 12 mm thick Teakwood with a glass front and padlocking and sealing arrangement as per standard practice. Pad locks to be supplied by contractor, all materials i.e. Teakwood, handle, hinges, Glass sheet of 3mm thick to be supplied by the contractor. Box to be polished and description to be painted as per instructions of Engineer in charge. |
| 29 | Wooden block counter of size 700 mm x 700 mm W x 900 mm H made of teakwood frame & 10 mm /20 mm thick water proof ply with formica finish on top and all four sides having two compartment inside & two doors on opposite sides. |
| 30 | Office Chair of continuous arms having cushened seats and rest T.W. Arm rest size 36\\" x 21\\" x 22 approx steel tubular frame gauge of the pipes 25mm dia x 18 gauge with olive green colours, Green stove enamelled \\"Indian Make\\". |
| 31 | Office Table of size of table top 1220 mm x 610mm height 750mm with laminated top with 3 drawers on the left hand side and one locker on the right hand side olive brown with Duplicate keys. Olive green colour |
| 32 | Plain storage almirah with 4 adjustable shelves size 1980mm height, 915mm width, 485mm depth, |
| 33 | Airy Revolving and tilting working cushioned adjustable height chair with arm rests, polished black.The chair has plastic caned seat and back on 25 mmround tubular frame. The base is of pressedsheet metal. Width 700 mm,Depth 700 mm, Height 870 mm, Adjustable seat height 410 mm to 520 mm, Colour Grey. |
| 34 | 4 door book case of size 1675x840x308mm |
| 35 | Supply & fixing of Fire Extinguisher CO2 Type (capacity 5 Kg) |
| 36 | OUTDOOR SUPPLYRelay 'Q' series neutral line, AC Immune, plug-in type, Style `QNA1'. DC Neutral line, 24V, 8F/8B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 with latest amendment (as applicable). The interlocking code for this unit shall be ABDGH. |
| 37 | PVC Insulated Armoured un-screened, under- ground Railway Signaling copper conductor cable confirming to RDSO Specification no. IRSS- 63/2014 with amendment -4 or latest(a) 12 core x 1.5 sq.mm. |
| 38 | Underground railway jelly filled 6 Quad cable for signalling & telecom installations confirming to IRS: TC-30/2005 (Ver. 1) Amndt 1 to 5 or latest amendment having 0.9mm dia. |
| 39 | Armoured Optical Fibre cable 24 Fibers as per RDSO specification No. IRS:TC:55-2006 rev. 1 with Amdt. 1.1 |
| 40 | Cable unarmoured PVC insulated, unseathed with plain annealed high conductivity 650V grade copper conductor as per colour coding scheme of Raliways in 100 meter coils, confirming to RDSO Specification No: IRS-S-76/89 with latest amendment- |
| 41 | i) 16 x 0.2 mm.(Grey) |
| 42 | ii) 3 x 0.75 mm. (Red, Green & Black) |
| 43 | iii) 1x6 sq mm. (multistrand flexible wire) |
| 44 | iv) 1x10 sq mm. (multistrand flexible wire) |
| 45 | v) Supply of Power wire as per IRS specification No.S-76/89 ( Amndt. 2) or latest with latest amendments (1x16 sq mm, Red & Black colour) |
| 46 | Thermo Shrink joining kit suitable for 6 QUAD jelly filled cable-straight through as RDSO specn. No.IRS: TC 77/2012 (Rev.3.0) with (Amdt.-1 to 3) or latest. |
| 47 | Supply of HDPE telecom duct with outer diameter of 40 and inner diameter of 33 mm permanently lubricated as per Specification no. RDSO/SPN/TC/45/2013, Rev.-2.0 Amdt.-1.0 & 2.0 or TEC GR No.G/CDS 08/02 Nov.2004 with latest amendment as available or latest. HDPE pipe shall be supplied For each Km. of HDPE duct following items are to be supplied alongwith 4 mm dia polypropylene rope of approved quality inside whether required. For each Km. of HDPE duct following items are to be supplied a) End plugs-2 No.b) Cable sealing plugs - 2 Nos.c) Plastic couplers slip fit/push fit type-2 No.d) End plugs to be provided along with drum - 2 No. |
| 48 | Supply of Half split double wall corrugated (DWC) pipe of HDPE in 2/3 meter length produced out of full round DWC pipes as per IS:14930 part-II marked on it. This item includes supply of necessary fixing & coupling arrengement. b) Size : 200 mm outer dia. and 175 mm inner dia. |
| 49 | Non-Split HDPE DWC pipe Confirming to IS:14930 part-II, with threaded coupler, of following sizes:b) Size 200mm outer dia and 175 mm inner dia |
| 50 | Supply and placing of second class bricks/Fly Ash brick size 225mm x 112mm x 75mm after laying of cable & refilling the trench by loose soil of 100mm to over cable. |
| 51 | Galvanised Iron pipe 100 mm dia `B' class,(6 Mtr. Length) as per specn.No.IS-1239, part 1 / 1990. along with threaded coupler (Perforated with 6 mm holes) |
| 52 | Fabrication, supply and fixing of cable marker of 1:3:6 concrete as per No.NR/S&T/CON/1.5/97A. The marker shall be fixed at various places of cable route as per instructions of Engr. at site |
| 53 | Colour light signal (2 aspect) complete set as per drg.No.SA - 23003 A/M (adv.) & Specn. IRS-S-26/64 consisting of the following items :a) Signal post 140 mm dia 4.5 mtrs. long to IRS-S-6-81. b) Signal base Cast Iron 140 mm dia. to drg. No. S-2011/M.c) CLS ladder complete with platform and base 4.5 mtrs. long to drg.No.SA-23153 (Adv.) Alt 1.d) Colour Light Signal Unit 2 Aspect complete with out signal transformers, lenses & lamps, suitable for 140 mm dia.post as per drg.No.SA - 23003 A/M (Adv.) alt.9 & Specn. IRS-S-26/64.e) 04 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78 |
| 54 | Colour light signal (3 aspect) complete set as per drg.No.SA23002 A/M (adv.) & Specn. IRS-S-26/64 consisting of the following items :a) Signal post 140 mm dia 4.5 mtrs. long to IRS-S-6-81.b) Signal base Cast Iron 140 mm dia. to drg. No.S-2011/M.c) CLS ladder complete with platform and base 4.5 mtrs. long to drg.No.SA-23153 (Adv.) Alt 1.d) Colour Light Signal Unit 3 Aspect complete with out signal transformers,lenses & lamps , suitable for 140 mm dia.post as per drg.No.SA - 23002 A/M (Adv.) alt.9 & Specn. IRS-S-26/64.e) 04 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78 with latest amendment. |
| 55 | Junction type route indicator 3 way complete without lenses, lamp holders and lamps. to IRS-S-66/84 , amdt.1 ot latest with RDSO drg.No.SA-23402 (Adv.) or latest. |
| 56 | OFF set bracket for Colour light signal 140mm outside dia. post with 'U' bolt and nuts as per drg No: SA-23080 (adv.) alt. 1. |
| 57 | Independent shunt signal complete having following items.a) Shunt signal post 90 mm dia 1m long to IRS-S-6/81.b) Shunt signal surface base 90 mm dia drg.No. S-2011.c) Position light shunt signal unit without lamp holder unit, lenses & lamps to RDSO drg.No.SA-23840(adv.) ALT-2. d) 04 nos. anchor bolts for shunt signal (305mm. X 50mm. X 20mm.) to drg.No.SA-110 A/M. |
| 58 | Shunt signal dependent type drg No. SA-23840 (adv.) Alt.-1 and S-23845 (adv.) with offset bracket 3½'' dia. to suit 140mm. Outside dia post complete without lenses, lamps & lamp holders. |
| 59 | Calling on signal unit position light type complete with mounting socket to Drg No. SA-24351 (Adv) or latest, specn. No. IRS-S:10/78, IRS-S:26/64. |
| 60 | LED signal lighting unit for Junction Type route indicator conforming to Indian Raiway chromaticallity standards & RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 or latest (This item includes fuses and other accessories required for fixing) |
| 61 | LED signal lighting unit for calling on signal conforming to Indian Railway chromaticallity standards and RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 or latest (This item includes fuses and other accessories required for fixing) |
| 62 | Supply of LED Signal Lighting Unit for Main Signals as per RDSO specification No. RDSO/SPN/199/2010 (Rev 1.1) ) or latest |
| 63 | a) For Red aspect |
| 64 | b) For Yellow aspect |
| 65 | c) For Green aspect |
| 66 | LED signal lighting unit for shunt signal conforming to Indian Railway chromatically standards and RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 or latest (This item includes fuses and other accessories required for fixing) |
| 67 | Supply of Electronic Timer Relay, 24 V DC, 60/120 sec. |
| 68 | Supply & Transportation of Double Line Block Proving by Axle Counter (BPAC) using Block Panel and UFSBI complete with all accessories as per Specification No. IRS:S-105/2012 (Ver.0) or latest. Each set consists of following: (i) Universal Fail Safe Block Interface complete with all accessories as per Specification No. IRS:S 104/2012 (Ver.0) or latest– 2 sets, (ii) Block panel complete with all accessories as per Drawing No. RDSO/S/32017 – 2 sets, (iii) Relay Rack with locking and sealing arrangement duly wired as per RDSO Drawing No. RDSO/S/32018 including all Relay wiring and supply of all type of Relays – 2 sets. (iv) Block Telephone with accessories as per Specification No RDSO/SPN/191/2005 or latest with all type of lighting protection and in-built automatic media change over with Voice/E1/Dark Fibre port – 2 sets (v) Sort of indoor cables, ladder etc. The actual requirement of communication modem shall be advised by Engineer in charge of the site. |
| 69 | Designing as per SIP & Supply of Multi Section Digital Axle Counter System (MSDAC) complete system as per RDSO Specification No .RDSO/SPN/176/2013 (Version 3 ) or latest consisting of:‐1) Central evaluator Unit2) SM’s Reset Panel3) Field unit along with web detector4) Centralised High Voltage DC‐DC convertors5) Final track clearance relay for each section along with accessories equipped for detection points and track section. 6. Maintenance free earth for DP, Location boxes and evaluators as per OEM' requirement. |
| 70 | Tool Kit of MSDAC consisting of the following:‐1) Portable Data Analyser with Data Analysis software for report generation & Analysis‐1 No.2) Pure Sine wave Digital Multimeter No.859CF or equivalent – 1 No.3) Dummy Wheel CEL makes – 1No.4) Ring Spanner 17‐19, 24‐26 – 1 No. each5) Open end Spanner 17‐19, 24‐26‐ 1 No. each6) Socket Spanner with handle – 1 no.7) Screw Driver No.902 – 1 No.8) Screw Drive No.935 – 1 No.9) Torque Wrench – 1 No.10) Marking jig for drilling – 1 No.11) Monitoring Unit‐ 1No |
| 71 | Electrical point machine, IRS heavy duty non-trailable rotary locking type 143mm throw to operate on 110V DC complete with lock & detector slides and cable termination box as per IRS:S-24/2002 (Amd 1) & IRS-S-37/82 (Amd 3 or latest), Drg. No. S-10910 for motor Assembly Drg. No. S-10800. (One No. tool kit will be supplied for installaton for a group of 08 Nos of point machine) including ground connection |
| 72 | Insulation for gauge tie plate for BG as per IRS-S-40/84 and drg.No.T-10372, T-10368, T-10371 each set comprising of :a) Insulating plate - 2 No.b) Bushes - 6 No.c) Washers - 12 No. |
| 73 | Insulation for following & leading P-way stretcher bar for BG as per IRS-S-40/84 & drg.no.10367 10368 & 10371 each set comprising of :a) Insulating plate - 2 No.b) Bushes - 2 No.c) Washers - 4 Nos. |
| 74 | Insulation for 'P' bracket for point machine as per Rly. design each set comprising of :a) Channel side plate LH -2 No.b) Channel side plate RH -2 No.c) Bushes - 4 No.d) Washers - 4 No. |
| 75 | Supply of Electric Point Machine (Non – Trailable) IRS type, 220 mm through to operate on 110 V DC complete with Lock and detection slides and cable termination box, as per Specification No. IRS:S-24/2002 or latest and for Motor IRS:S 37-2022 or latest, Ver 2.0 or latest with External Clamp Point Lock 60 kg. A) Dimensions of fixing arrangement of point machine shall be as per drawing No. RDSO / S 11000 or latest. B) Ground connection with Nylon insulation set confirming to RDSO Drawing No. S-3454 and Clamp Point Lock confirming to RDSO Drawing No. 3495 for 60 KG Thick Web Switch. C) AC Immunity Level of Motor for Electric Point Machine should be of 160V AC, RMS at 50 Hz. D) Junction box and two numbers of telescopic pipes of approved type shall be supplied as an integral part of the point machine as per Specification NO. IRS:S-24/2002 or lates Note: This includes supply of Set of tools as per para 20.1 (1 set with every 8 set point machine or less.). |
| 76 | Steel Appratus case Full, complete with `E' type lock & keys to drg. No.RITES/SIG/GEN/043-08. The E type lock shall have ward No. 32. |
| 77 | Steel Appratus case half, complete with `E' type lock & keys to drg. No.RITES/SIG/GEN/044-08. The E type lock shall have ward No. 32. |
| 78 | Key Lock 'E' type with key Drg.No.SA-3376/M. Alt-2. Spec.No.IRS-S-30/64 different wards. |
| 79 | Design, prepearation & supply of Six (06) hard copies of each documents along with soft copy for the mention below alongwith original tracing on a standard 7.5 microne polyester film in AUTO CAD FORMAT. (The item includes supply of two sets of drawings for approval and corrections thereon as suggested by RITES) i) Cable route plan ii) Location box details with location wiring diagram iii) Cable termination detailsiv)Cable corage plan v) C.T. Rack detailsvi) Track bonding plan vii) Cable jointing detailsviii) Signal lighting circuit ix) Circuit diagram for LC Gate No. x) Gate Working Rule with Gate Signal Diagram |
| 80 | Supply of SLB/BSLB/SB/GWB/C-on Board as per RDSO Drg No SA-2373 with latest amendment, Casting, concreting and curing of foundation & erection SLB/BSLB/SB as per Drg No.NR/S&T/CON/7.4/97 has to be done by contractor. |
| 81 | Various types of markers as |
| 82 | P markers as per drawing no. RITES/SIG/GEN45-08 circular disc made of 3mm. thick white laminated MS sheet shall be used. Letter 'P' shall be written in black. |
| 83 | C markers as per drawing no. RITES/SIG/GEN45-08 circular disc made of 3mm. thick white laminated MS sheet shall be used. Letter 'C' shall be written in black. |
| 84 | Signal number plate as per drawing no. RITES/SIG/GEN46-08 3mm. thick white laminated MS sheet shall be used. Letter shall be written in black on yellow background. |
| 85 | Installation & Supply of basic material to construct Maintenance Free Earth for Ring Earth consisting as per Specification No. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing no. SDO/RDSO/E&B/002 or latest. and as per TAN No.TAN/3006/D1 dated-05/06/2025 (a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm dia. minimum with copper bonding thickness of min 250 micron and UL listed and marked -1 No. (b) Earth Enhancement compound supplied in sealed bags of min 30-35 Kg.- 1 Nos. (c) Copper Strip of 200mm x 25mm x 6mm to exothermically welded to Earth electrode- 1 No.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) – 1 No. (e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 No.(f) Supply of 50 mm x 6 mm Galvanised steel tape for interconnecting the earth pits. (g) Supply of 25mm x 2 mm bare copper strips or 8mm round solid copper in the equipment room.(h) Supply of Copper Tape of size 25x6 mm for Bonding ring conductor to be mounted on insulated standoff. (i) all necessary material required for Ring Earth |
| 86 | Supply, writing and fixing of description boards made of ply 6mm thick with white sunmica glued over its surface and 1\\"x1\\" wooden batton fitted all around onthe rear as per instruction of Engineer at site. All the materials to be supplied by contractor. |
| 87 | Supply & laying of anti-static PVC flooring with adhesive ( 2.00 mm thickness) in Relay room/equipment room/Data logger room/Axle counter room as per instruction of Engineer at site. |
| 88 | Supply & transportation of Single Section Digital Axle Counter phase reversal type as per Specification No. RDSO/SPN/177/2012, Ver.3 or latest without tool kit. The length of Tx & Rx cable shall be of 5/10/15 m to meet the site requirements. This also includes supply of Mushroom and/ or Location Box or both suitable for housing Track side equipment as per OEM requirements. |
| 89 | Supply & transportation of tool kit of SSDAC/HASSDAC phase reversal type as per Specification No. RDSO/SPN/177/2012, Ver.3 or latest. |
| 90 | Supply of Hydrometer of reputed make for measuring specific gravity of the battery graded acid with mounting stand in battery room /location boxes. |
| 91 | Supply and Installation of class A type Lightening Protection System as per following specification are as under, (i) Lightening arrester technology: Advance Early Steamer Emission. Material: High current discharge stainless steel. International standards: NFC 17- 102 or latest., (ii) Mast material: minimum 2 meter FRP pipe and minimum 3 meter high-grade aluminium/steel. Dimension: 50mm., (iii) Down conduct cable: 50 Sq. mm PVC insulated copper cable having 75m length, (iv) Lightning strike counter: 6 digits counter, Current sensitivity: 1KA to 200 KA, 8/20 & 10/350 micro/Sec. induction Shunt: 0.5 micro. (v) Two (02) No. of maintenance Free Earth with all required accessories as per Specification No. RDSO/SPN/197/ 2016 Ver 1.0 or latest such as copper cables, strips etc |
| 92 | Supply of electronic Cable Route Locator/Tracer equipmentof C-scope |
| 93 | Supply of Digital insulation Tester (Megger) 100 V, |
| 94 | TELECOM SUPPLYSupply of managed SDH (STM-1 Add/Drop MUX and upgradeable to STM-4) fully wired for 2 X 63 MB and equipped for 21E1s and a virtual container (VC-12) with STM1 (L1.1) aggregate interface including power supply, order wire, Ethernet card, sub rack, inbuilt DDF, installation material and all other accessories, manuals etc. as per TEC. Specification GR SDH 04/02, March 02 or latest. The contractor will supply all other accessories as mentioned in the above said TEC Specifications and system will have provision of different redundancy cards as per the TEC Specifications. Note: It shall be possible to increase capacity from 21E1 to 63 E1s by adding / inserting tributary cards. This includes connecting all pig tails, optical patch cords etc. to the SDH equipment. This also includes connecting the SDH equipment with all cards to the 48V Bus including supply of wires and connectors. Termination of all E1s on DDF taking PVC cable over runway or a wall. At the terminal station, one port may be disabled if required as per instructions given by site engineer incharge. |
| 95 | Supply of 2 MB programmable Primary Digital Drop/Insert multiplexer with conference facility as per RDSO Specification No. IRS: TC-68/2012 Amd.1 or latest wired for 30 Circuits complete with power supply, Control and Basic/Common cards, Remote control supervision facility and all other accessories etc. The mux shall be equipped with fallowing interface cards A) 2W/4W E&M interface card (4 ckts per card)-04 Nos. B) FXO Exchange loop interface card (4 ckts per card)-2 Nos. C) FXS Subscriber interface card (4 ckts per card)-02 Nos. |
| 96 | Supply & transportation of 48V/50 A SMPS based power plant in 2+1 configuration using 3 Nos. of 48V/25A modules to charge the VRLA battery bank of 48V/200AH with lightening & surge protection as per Specification No. RDSO/SPN/TC/23/1999 Ver.4 Amnd.1 or latest. |
| 97 | Supply of 48Volt/200AH Maintenance free VRLA batteries duly charged as per SpecificationNo. IRS: S93/96A (with latest Amendment) |
| 98 | Supply, installation & commissioning of 4 wire DTMF way station Equipment as per RDSO specification No. IRS:TC:60/93 with Amnd. 4 or latest alongwith compatible way station telephone as per RDSO Spec. No. IRS:TC:38:97 with Amnd. No. 1. Item includes their, installation, testing & commissioning with contractor's all materials required for installation. |
| 99 | Supply of 4 wire DTMF Control Telephone spec.IRS-TC-38/97 |
| 100 | Supply, installation & commissioning of Power supply for DTMF equipment/Selective calling telephone to RDO spec. IRS:TC:72:97(or latest) with 12v 7AH battery |
| 101 | Suppy of 10 pair PIJF-0.63mm cable |
| 102 | Suppy of CAT-6 cable 10/100/1000 MBPS |
| 103 | Supply of Desk type Electronic Magneto Telephone (DTMF) as per Specification No. IRS: TC/79/2000 with amd 4.0 or latest |
| 104 | Supply of maintenance tools kit as per TEC Specification No. GR/OFT-01/03 APR 2005 or latest, one set consisting of following:-(i) Digital multi meter 4 1/2 digit with Liquid Crystal Display 1 No. (ii) Utility knife - 1 No.(iii) Cable Slitter - 1 No.(iv) Tubing cutter for cable armour - 1 No.(v) Bare fiber adaptor - 1 No.(vi) Miller High precision stripper for fiber buffer - 1 No.(vii) Cleaver Fujikura make or similar - 1 No.(viii) Mechanical splice joint set - 1 set consisting of 6 Nos.(ix) Ceramic scissor CSI - 1 No.(x) FC/PCAdopter with ODB loss - 10 Nos.(xi) Optical fiber terminal block V groove - 2 Nos.(xii) Earth resistance measuring instrument with all accessories suitable for measuring earth resistance in range of 0.1Ohms to 10 Ohms.(xiii) MEGGER(a) 500v - 1 No.(b) 100v - 1 No.(xiv) Loose tube stripper - 1 No.(xv) Cord stripping pliers - 1 No.(All the tools have to be standard/imported makes). |
| 105 | Supply of Antistatic mats of size 1 mtr x 0.7 mtrs (2 mm Thick ) |
| 106 | Supply of 24 fiber optic fiber straight joint enclosure (SJC) complete with all accessories |
| 107 | Supply of VF tapping transformer as per IRS/TC/22/76 of impedance ratio - 1120:470. |
| 108 | OFC Termination box for 24 fibre. |
| 109 | Supply & installation of CT Boxes for 20 Pair. |
| 110 | Supply of EC socket box as per RDSO spc. No.IRS: TC-42-87, amendment-1 or latest. |
| 111 | Supply of 6-pin emergency plug & socket flat type as per RDSO spc.no. IRS:TC-42-87. |
| 112 | Supply, fixing, testing and installation of 5wt VHF hand set with charger |
| 113 | 25wt VHF set with al accessories and Batter back up |
| 114 | All miscellenious wiring materials for wiring of telecom facility such as ladder, board for fixing CT Box, Wago connector, Earth bar and insulater etc. |
| 115 | FAT and SAT as per modified and approved application logic by IRSE/IRSTELO licence holde |
| 116 | RCC,Inteface checking, verification &/or approval of Interface circuit & Logic Circuit by IRSE/IRSTELO licence holder upto 50 routes |
| 117 | Additional payment for checking, verifying and approval of RCC Interface circuit & Logic Circuit by IRSE/IRSTELO licence holder having more than 50 routes |
| 118 | Preparation of Station Working Rules, CRS papers etc as practice in Railways for yards/LC Gate/IBH |
| 119 | Schedule-B (Execution of Signalling & Telecommunication work) |
| 120 | Installation, wiring, programming, Bell test,Site acceptance test (SAT), commissioning, Screening arrangementnt with Copper strips ,lightening- protection arrangement,Earthing wiring etc as per Railways practice and All Pre-commissioning tests of EI at loading & holding yard and other equipments supplied against each station, as per latest technical specifications of RDSO and OEM . This also includes preparation of design documents and supply of materials for installation, wiring, grouting, cutting of floors, walls etc. refilling of same, replastering, required CC/mesonary works, termination of cables with lugs/connectors, painting/lettering on relay rack/termination rack are to be done by the contractor. |
| 121 | Training for O&M Staff |
| 122 | i) Training of Technician/Jr. Engineers in installation, Testing, commissioning & trouble shooting of Electronic interlocking supplied against item no. 1 of this schedule including provision of hard copies of course modules for each trainee. |
| 123 | ii) Training of Sr. Engineers/Managers in installation, Testing, commissioning, trouble shooting and Repairs supplied against item no. - 1 of this schedule including provision of hard copies of course modules for each trainee. |
| 124 | Testing and commissioning of complete signalling system integration with outdoor gears ,slotting, etc at the staion as a whole. All artisan staff and labours required for testing and with MACLS work shall be provided by contractorfor for indoor and outdoor work. Testing equipment such as simulation panel, signal and point operation simulation arrangement, multimeter,etc. shall be provided by contractor at his own cost. testing shall be carried out by contractor in presence of engineer-in-charge up to his satisfaction and neccesary alterations shall be done. Contractor shall depute sufficient staff to carryout outdoor work during commissioning for completion of work within stipulated time.It also includes provision of temporaty tents/Huts,arranging lights,Chairs & tables, provision of temorary telphones,snacks/drinking water for NI staff round the clock at site etc as reqired duing the NI period in Railways. |
| 125 | Termination of all cores of all types of Indoor/outdoor cables (Excluding termination in location boxes and terminations on items coming under item No.1 of Schedule A (Supply )after its laying, on both ends and providing number ferrule on each core. This also includes fixing of ARA terminals/disconnecting type terminal block/ 8 way strip, meggering and preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately. This also includes dressing and lacing of cables on both ends. Proforma for testing and material for lacing to be supplied by the contractor. |
| 126 | RELAY ROOM:Erection of cable termination rack. Clamping of cables, Numbering of cables with engraved aluminium strips, Supply of nuts & bolts, MS clamps & cement for massonary works.This will also include paintng of Cable/core particulars for each trminationwith contractors own paint.The place for erection of Termination Rack shall placed as decided by Site Engineer |
| 127 | Installation of relay rack assembly complete alongwith wall supports, sccaffolding, ladders/runway for cables, relay base plates etc. This includes Fixing of Relays with retaining clips, Fixing of disconnecting type terminals/ARA Terminals, PBT Fuse bases( supplied under Schedle A,) , termination of cable cores/wires, Supply of nuts & bolts, MS clamps & cement for massonary works.:This will also include Painting of Relay description on the front side and back side of the Relays as per instruction of site engineer. |
| 128 | Necessary arrangement for manufacture, transportation & installation of station masters console for fixing telephones & other equipments as per instruction of Engineer incharge. This includes : All materials like 25mm thick hylum sheet etc. required for the above including sundry items like bolts & nuts, screws, MS angle / flat shall be supplied by the contractor. |
| 129 | POWER SUPPLY/BATTERIES:Installation, wiring, testing and commissioning of Integrated Power Supply (IPS) system, at station/cabin as per technical specification and instructions given in Installation manual of OEM. Approval for installation drawings shall be obtained from project consultant before installation. This includes supply of all materials required for installation and initial charging of low maintenance Lead-Acid batteries (3 cycles). |
| 130 | Installation of DG set, testing and commissioning. This includes casting of vibration free foundation, installation of ASM panel, outlet for exhaust panel, laying of power cable from DG room to ASM room for remote operation of DG set and wiring of DG set of ASM panel, laying of cables/wires should be carried out in HD PVC channel/ conduit pipe. This includes cost of all mateials required for installation except DG set and perASM panel. Wires/cables as extant practice on Railways and instruction of Engineer at site. |
| 131 | Installation,wiring,testing & commissioning of LT power panel with auto change-over at Central Cabin. This includes fixing of power panel.termination of LT cables & fixing of Auto-change-over management and its wiring and supply of MS angle,nuts & bolts etc. |
| 132 | Excavation of Trench, Depth 1.0 Mtr. & width 0.3 Mtr., in all soils including soft/hard rocky area and clearing of roots of trees, bushes, rocks etc., ballast and reconditioning etc., (including bailing out water and disposal of extra soil) including back filling with excavated earth and ramming of trenches after cable laying for the following depth and width as given below. The contractor has to conduct detailed site survey of the cable route. Prepare a plan to get approval of the owner's authorised representative, putting white lime powder marking before excavation of earth under supervision of owner's authorised representative. Wherever several cables of different categories have to be laid in the same path, all cables shall be separated with brick through out the length, instead of seperate trench in the concerned area. |
| 133 | Excavation of cable trench of 1.0 m. depth & 300 mm. wide across the track width at level / track/Road crossing platform & refilling after laying DWC/RCC pipe (laying of DWC/RCC pipe shall be paid under separate item of schedule) as per cable route chart & technical specification as per Drg.NO.NR/SIG/CABLE/005. This include repairing and plastering of platform/pucca road after cable laying. NOTE:- Power cable, signalling cable, Quad cable, PIJF, OFC etc. as mentioned above, where required, shall be laid in the same trench as signalling cable but in a separate pipe. |
| 134 | Cutting smoothening of inside surface of chase in concrete or hard rocks having size 80mm depth & 70mm width. This work includes laying & covering of cable laid in the chase with brick (225 x 100x 75 mm) i.e. 9 bricks per meter second class bricks placed & embedded longitudinally & plastered on the top of the bricks as per drg No. RITES/SIG/GEN/025-98. This item includes the cost of bricks, cement & sand etc. |
| 135 | Filling of cable duct by sieved silver/fine sand after laying of cable in relay rooms. Supply of sand shall be made by the contractor. |
| 136 | Fixing/ laying of DWC/RCC pipes for laying of cables (including under-neath the track, Road crossing or other platform cutting etc.) as per drg.No. NR/SIG/CABLE/006. |
| 137 | Fixing of Galvanised iron pipe 100 mm dia. on panel buildings. This includes supply of clamps, support, nuts, bolts etc. & concreting of ends with brick masonary work including supply of cement, sand an aggregate. |
| 138 | Laying of 40/33 mm dia HDPE pipe as per approved cable route plan in the excavation trench at 1 mtr depth. |
| 139 | Transportation of cables in roll with or without wooden drums to work site and meggering before loading and after laying, and recording the values in cable insulation register along with representative. |
| 140 | Laying of signalling/Telecom cable in the trench/GI/RCC/DWC pipe as per cable route plan (Note: before issuing of cable to the contractor, the cable will be meggered jointly by the contractor and RITES Engineer at site and meggering certificate will be submitted in the office of the Engineer In Charge. Where cable is laid in HDPE pipes, no protective bricks are required. The same procedure will be adopted after the cable in laid at site without which no payment will be made to the contractor. If the insulation resistance after laying of cable is less than the reading previous meggering report. The contractor will have to repair or replace the defective cable at his own cost for which no charges will be paid . |
| 141 | Providing Heat Shrinkable joint for all type of S&T cable with contractor's all materials.All the materials required for the work are to be arranged by the contradtor himself at his own cost except Thermoshrinkable jointing kit which is already covered in Supply portion of the tender.After jointing the cable through test such as insulation test,Continuity cable losses etc. to be carried out jointly with the Railway Engineer. If any defect or any damage observed during jointing, the contractor should redo the joint free of cost. |
| 142 | POINT MACHINEInstallation, wiring, testing and commissioning of 110 V, DC point machine as per specifications and approved wiring diagrams. This includes:i) Fixing of point machines on MS plate fixed on sleepers complete with fixing of anti theft covers, cable terminal box, ground connection.ii)Fixing of insulation for gauge tie plate and crossing plate for 52 / 60 Kg. points and crossings.iii) Fixing of insulation for switch extention pieces (D brackets) and leading & following stretcher bars.iv) Wiring from the cable termination box to the point machine as per specifications.v) All smithy works.vi) Supply of MS plates, flat, angle, bolts, nuts, pins as required.This item also includess supply & fixing of GI pipe bend for the protection of cable from cable termination box to piont machine.vii) Testing the point machines from point of operation including testing with 5 mm test piece. |
| 143 | P-way works required before provision of point machines such as .squaring of switches, packing and leveling/alignment of track,easing or rails on either side of points to be interlocked,making proper spacing of sleepers etc |
| 144 | Fabrication, supply and erection of number plate for point machine as per Drg. No. RITES/S&T/ROU/ PMNP-01 and as per instruction of Site Engineer. This includes supply of MS Plate (Size: 350mm x 250mm, 3mm thick), MS Angle (Size: 25mm x 25mm, 3mm thick), Cement, Sand, Aggregate, Paint and all other material required for this work. All the smithy mechanical and electrical work/arrangement shall be done by the contractor at his own cost. Point Number shall be written in black on yellow background in 150mm height on both side of the plate. |
| 145 | Axle counterIntallation, programming, Testing and Commissioning of Central Evaluators of MSDAC supplied against item no. 38 of supply schedule (Bill-1) at panel building, wiring from CT rack to the Central Evaluator, Installation and wiring the reset box and wiring the power supply to the Central Evaluator including the supply of shielded cable of required conductor size as applicable with other accessories, with their own material. Note: 1. Variation in detection points and/or track sections upto (+) 10% shall have no cost bearing. |
| 146 | Installation, Testing & Commissioning of track device (double rail contact) including digging of trench, track crossing, laying of double walled antirodent corrugated pipe from track device to track side housing and making its terminations. Termination of 4Quad cable in track side electronic box. Fixing of deflector plates. (Double walled antirodent corrugated pipe made up of high density polyethylene of required diameter and all other accessories as per site requirement to be supplied by the firm & installation of EJB/ Track side electronic box inside the track side housing, including supply of wires and other accessories. |
| 147 | P-way work required for provision of Axle counter track detection devices to be fixed on rails including work involving re-spacing of sleepers, packing of sleepers etc |
| 148 | Installation, Testing and Commissioning of Double Line Block Proving by Axle Counter (BPAC) using Block Panel and UFSBI complete with all accessories as per Specification No. IRS:S-105/2012 (Ver.0) or latest. |
| 149 | COLOUR LIGHT SIGNALSExcavation of pit, casting & plastering of concrete foundation for C.L.Signal & ladder. as per drg.No.SK-15/10. This includes : Supply of cement, sand, stone chip & mixing in the ratio 1:3:6. |
| 150 | Erection of 2 aspect colour light signals.This includes :i) Erection of surface base, signal post, signal unit, junction type route indicator, shunt signal on offset bracket,calling on signal, ladder with guard & platform. Fixing of signal number plate, P/C/G marker & blanking-off signals. It will also include protective screen, wherever required.Fixing of hoods & LED lamp units with current regulating transformer on 2 aspect signal. Termination of the tail cable in the signal unit.This incuded digging/pulling of cable already laid. This item includes the cost of all the fixing materials required to execute this activity.ii) Wiring & testing of signal unit as per the specifications and directives of engineer at site. |
| 151 | Erection of 3/4 aspect colour light signals.This includes :i) Erection of surface base, signal post, signal unit, junction type route indicator, shunt signal on offset bracket,calling on signal, ladder with guard & platform. Fixing of signal number plate, P/C/G marker & blanking-off signals. It will also include protective screen, wherever required.Fixing of hoods & LED lamp units with current regulating transformer on 2 aspect signal. Termination of the tail cable in the signal unit.This incuded digging/pulling of cable already laid. This item includes the cost of all the fixing materials required to execute this activity.ii) Wiring & testing of signal unit as per the specifications and directives of engineer at site. |
| 152 | Testing & commissioning of 2 /3/4aspect colour light signals. |
| 153 | Excavation of pit, casting & plastering of concrete foundation for shunt signal. As per Drg. NoSK-16/10. This includes : Supply of foundation nuts & Bolts, cement, sand, stone chip & mixing in the ratio 1:3:6. |
| 154 | Erection of shunt signal. This includes :a). Erection of surface base, shunt signal post, shunt signal unit.b). Fixing of hoods and LED lamps with regulating transformer.c). Termination of the tail cable in the signal unit.d). Wiring of shunt signal unit with wiring material.e) Necessary arrangement of material to be used by bidder own arrangement |
| 155 | APPARATUS CASEExcavation of pit, casting of concrete foundations for full location box as per Drg.No.NR SK -18/10. This includes : Supply of Foundation Bolts and nuts, cement, sand, stone chip & mixing in the ratio 1:3:6. |
| 156 | Erection of full location box on foundation including fixing of `E' type lock & locking arrangement, wiring, testing & commissioning as per approved disposition plan & wiring diagram. This includes - (i). Necessary arrangement of material& fixing of hylum sheet on 25 x 25 x 3 mm angle iron frame , resin bonded 10 mm thick grade P3 in standard size for shelves, boardfor fixing ARA terminal, disconnecting type terminal blocks, fuse blocks etc.(ii). Termination of cables with number embossed ferrules, bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamps etc.This also includes clamping of cables with contractors own material(iii). Filling up pit inside the location box by sand and plastering on the top of the sand.(iv). Fixing of terminals, 8 way strips, disconnecting type terminal blocks, fuse blocks, N.D. fuses, etc. as per approved wiring diagrams.. |
| 157 | Excavation of pit, casting of concrete foundations for half location box as per as per TS para.-8 &9 and Drg.No.Drg.No.SK- 17/10. This includes: (i) Supply of 4 nos. anchor bolts as per RDSO drawing no. SA-112A with nuts and washers. (ii) Supply of cement, sand, stone chip & mixing in the ratio 1:3:6. |
| 158 | Erection of half location box on foundation including fixing of `E' type lock & locking arrangement wiring, testing & commissioning as per approveddisposition plan & wiring diagram. This includes :(i) Supply & fixing of hylum sheet, resin bonded 10 mm thick grade P3 for fixing ARA terminal, fuse blocks etc.(ii) Bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamps etc.(iii) Filling up pit inside the location box by sand and plastering on the top of the sand.(iv) Fixing of angle iron frame for \\"Q\\" type relays in location box. This includes supply of angle iron for fixing relays.(v) Fixing of terminals, fuse blocks, N.D. fuses, etc. as per approved wiring diagrams and dwg. No. RITES/SIG/GEN/054-09 |
| 159 | Supply and Installation of Earth electrode assembly and concrete encloser with cover as per drg. No. RITES/SIG/GEN/013-98 and RITES/SIG/GEN/014-98 respectively. This includes providing connection to location box, signal unit, block instruments, cables etc. through GI wire 8 SWG suitably sparted on MS flats size 30 x 3 mm as per drg.No. RITES/SIG/GEN/015-98, RITES/SIG/GEN/016-98 & RITES/SIG/GEN/017-98. This includes:(i) Diging of pit in earth 3 m deep.(ii) Casting of cement concrete enclosure as per drg.No.RITES/SIG/GEN/014-98.(iii) Soil treatment as per standard practice involving supply & pouring of salt & charcoal.(iv) Connecting the equipment through earth lead wire & soldering.(v) Supply of cement, wiring material & soldering material. |
| 160 | Dismantling of the following: - |
| 161 | i) Signal posts/BSLB/SLB/Stop Board. |
| 162 | ii) Steel apparatus case with fittings. |
| 163 | iii) Relay racks with all fittings, battery racks complete, Equipment rack complete, SM`s slide. |
| 164 | iv) Battery charger, Battery set etc.TLBI, DLBI and other Misc. equipments. |
| 165 | v) Electric Point Machine |
| 166 | vi) Location Foundation/ Signal Foundation. |
| 167 | PAINTINGPainting of two coats of enamel paint over one coat of Red oxide primer on the following items after scrapping and cleaning of the surface whereever necessary. Primer & paints are to be supplied by contractor. Location boxes inside & outside surfaces with Aluminium paint. |
| 168 | Full case |
| 169 | Half case |
| 170 | Painting of Main signal post with signal unit, surface base complete with route indicator, dependent shunt, calling On unit, ladder fittings as per Indian.Rlys. standard practice |
| 171 | Painting of two coats of enamel paint black Asian and Aiuminium white as approved by Site engineer over one coat of primer on Shunt signal unit , base and post |
| 172 | Painting of two coats of enamel paint black Asian and red oxide as approved by Site engineer over one coat of primer on point machine and ground connection respectively |
| 173 | Cement concrete work for miscellaneous items with supply of cement, sand, stone chips and mixing in the ratio 1:3:6. This item includes excavation, raming, curing and plastering with cement & sand mixture (stone chips size not exceeding 40mm). |
| 174 | Providing brick massonary in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides. 20mm thick each with contractor's own IInd nd class bricks including excavation curing, grouting,bolting etc. Whereever required bricks sand and cement to be supplied by the contractor. |
| 175 | All work of horizontal boring and trenchless cabling along with supply, transportation and insertion of double wall corrugated pipe -( ISI marked ) conforming to RDSO Spec no.RDSO/SPN/204/2011, and the laying of cable in the boring under the track / road by usingpipe of size 120 mm outer dia,103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. (This item will be used for track crossing of running lines). |
| 176 | Blowing of OFC through HDPE duct & protective work (elicited in above item) already provided. Where it is not feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason, OFC shall be drawn/laid manually as per standard procedure. All the equipments and machinery required shall be arranged by the contractor at his own cost. In case OFC is to be laid adopting Direct in trench method then this item shall be paid as per accepted rate of item no. (6h) of this schedule. OFC and HDPE pipe shall be supplied by the railway. |
| 177 | Engaging mechanical excavators like JCB or other machineries for regarding and leveling the formation, dismantling any infringing structures, clearing and removing debris etc., with all lead and lifts etc., complete and as per the instruction of railway representative at site.JCB |
| 178 | Providing AC Road Vehicle mentioned below for the use of Engineer/Employer as directed by engineer-in-charge. Note: Agency should provide / withdraw vehicle / vehicles on advise of engineer-in-charge. Engineer-in-charge shall advise the requirement (for providing or for withdrawal of vehicle or vehicles 7 days in advance). Vehicles will be required to work upto 4000 Km in a month. (Average Kms of all vehicles in all months shall be upto 6000 Km). Vehicles shall be available on all days for 12 hours a day (except one weekly off)- Tavera , Innova or similar (Upto a maximum of 5 vehicles at any time) |
| 179 | Earth work for excavation and refilling around location boxes and signals etc. where necessary including 50M lead and 1.5M lift. The lead is to be measured from centre of gravity of location to the centre of filling and lift from main ground level. The earth work should be well rammed including breaking of clods,leveling and dressing etc. as per instruction of Engineer at site. |
| 180 | Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signalling system, releasing the cable coils to give access forshifting/ turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. if theexisting earth connection to the location boxes are disturbed the earth wires shall be the properly re-connected. (All materials required for the work shall be supplied by the contractor) (i) Shifting of apparatus case (full).Shifting of location box |
| 181 | Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signalling system, releasing the cable coils to give access for shifting/ turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. if the existing earth connection to the location boxes are disturbed the earth wires shall be the properly re-connected. (All materials required for the work shall be supplied by the contractor) (ii) Shifting of apparatus case (Half). |
| 182 | Installation of desk type magneto telephone with all accessories including standard battery box and 3nos. of 6I cells. All materials for this installation including standard battery box and 6I cells will be supplied by the contractor. Only desk type magneto telephone will be supplied by Railway(included as separate item of this schedule). |
| 183 | Wiring work of cable termination details of 6-quad, OFC, PIJF cables & equipments details at OFC Room/Cable hut & Station Building and wherever necessary as per direction of Engineer in-charge. |
| 184 | Splitting of Armour of Optical Fiber cable at the end and Splicing of 24 fiber optic fiber cable and making the splice joint with contractor's own splicing machine and tools. Acceptance Test Procedure of SECR has to be followed of testing. Continuity of the OFC Armour should not be maintained. |
| 185 | Fixing of PVC pipe 1\\" dia with good quality clamps and 3 nos of clamp should be fixed in one meter distance along with PVC bend where required as per specification A-4. |
| 186 | Fabrication of EC socket box, assembly and erection of fabricated assembly at the location indicated in the route chart and as per direction of Engineer-in-charge. |
| 187 | Painting of emergency socket assembly and rail post by applying one coat of red oxide as base colour and then painting the assembly as per zebra painting in white and block colours. The width of each of the black and white colours shall be 100mm. All paints used shall be with ISI mark. |
| 188 | Provision of \\"Earthing System for Telecom installations as per specification no. RDSO/SPN/TC/75/2008 with latest amendments.\\" |
| 189 | Installation of Antistatic mats in Repeaters, OFC/ cable huts and fixing of runway wires on OFC way in OFC/cable huts as per instructions of Engineer-Incharge. |
| 190 | Installation, Wiring, Testing, Validation & and commissioning of Data logger with 512 Digital and 32 Analog input with modem as per Specification No. IRS:S-99/2006 (Amdt-3) or latest |
| 191 | Installation, wiring, testing & commissioning of managed SDH (STM-1 Add/Drop MUX and upgradable to STM-4) fully wired for 2 X 63 MB and equipped for 21 E1s and a Virtual Container (VC)-12 with STM-1(L1.1) aggregate interface including power supply, order wire, Ethernet card, sub rack, inbuilt DDF, installation material and all other accessories, manuals etc. as per TEC. Specification GR SDH 04/02, March 02 or with latest amendment. |
| 192 | Installation, wiring of all 30 channels up to krone modules, testing and commissioning of 2 Mb Programmable Primary Digital drop insert multiplexer as per RDSO Specs. No. - IRS/TC/ 68/2012 Rev.0 with Amendment No.1 or latest. It includes submission of all technical documents, manuals and supply of all miscellaneous items which will be required for final testing and commissioning of the system. |
| 193 | Installation, testing & commissioning of 48V/50amp SMPS based power plant in 2+1 configuration using 3 Nos. of 48V/25A modules to charge the VRLA battery bank of 48V/200AH with lightening & surge protection as per Specification No. RDSO/SPN/TC/23/1999 Ver.4 Amnd.1 or latest. |
| 194 | Installation, wiring, testing & commissioning of 48Volt/200AH maintenance free VRLA Batteries duly charged as per IRS Spec. No. S-93/96(A) with amendments-1 or latest. |
| 195 | Installation, Testing & Commissioning of Single Section Digital Axle Counter phase reversal type as per Specification No. RDSO/SPN/177/ 2012, Ver.3 or latest without tool kit. This also includes supply & installation of maintenance free earth materials and exothermic bonding and other connecting Cable etc as per RDSO specification. No: RDSO/SPN/ 197/2008 or latest including foundation of Mushroom and/ or Location Box or both. Resetting equipment to be connected to the EI Ring earth |
| 196 | Shifting of HASSDAC/SSDAC from old location and installation, wiring, testing and commissioning in new axle counter room/ location box. This includes fixing of DPs at site if shifting required, evaluator in relay room/ location box or goomties together with termination of cables, fixing and wiring of LV boxes, painting, lettering etc as required. Necessary insertion/modification on the control/ indication panel to be carried out as per site condition. Note: 1 set means one end of the block section. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail