| 1 | Dismantling glazed tiles (to be carefully removed) |
| 2 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete.a Size 600x600 mm (14.115 a) |
| 3 | Providing and applying Anti Termite Treatment using post constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 3 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturers specifications by drilling holes in the floor slab & along skirting 300 mm apart & 12 mm dia, drilling holes along all possible entry points such as junctions of floor and walls, doorframes, sewage lines, entry points , etc. & injecting them with the chemical solution. (14.132) |
| 4 | Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer ofwhite cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. (14.135) |
| 5 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete (14.122) |
| 6 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. II (size of door 701mm to 850mm) (17.43 b) |
| 7 | roviding and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Pre-laminated particleboard with decorative lamination on Both side. (17.46 (ii)) |
| 8 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) -(i) Float glass panes of 5 mm thickness (17.47 (i)) |
| 9 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :-A 300mm x 16mm (17.49 A) |
| 10 | Providing & fixing 4\\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. (17.68) |
| 11 | Providing & fixing 6\\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. (17.69) |
| 12 | Providing & fixing 4\\" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge (17.75) |
| 13 | Providing & fixing 6\\" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. (17.76) |
| 14 | Providing & fixing 8\\" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. (17.77) |
| 15 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position Code : IS 2202-1(1999) 17-17.27 Decorative with teak facing on both sides edges lipped with teak with laminated core 17-17.27-(c) 17-17. 35mm thick (17.27 (c) (iv)) |
| 16 | Wire gauge fixed on chowkats with 25mm thick Hollock wood cover molding of full width (17.13 (ii)) |
| 17 | Renewing glass panes with putty and nails wherever necessary Glass panes weighing 10.75 Kg/sqm (31.5 (b) |
| 18 | Providing and fixing of Hollock wooden jafri fixed with 3\\" wide strips in wooden frame 3\\"x 1½\\" size supported with angle iron 50mmx50mmx6mm thick including painting/ priming coat etc. complete in all respect. (N.S) |
| 19 | Providing and fixing of 8mm thick toughened glass complete in all respect (N.S) |
| 20 | Providing and fixing stainless steel door stopper including screws complete in all respect |
| 21 | Providing and fixing of stainless steel hinges i/c screws complete in all respect |
| 22 | Providing and fixing of cupboard made of 19mm thick commercial board finished with Lamination from both sides (including partition and drawers) complete in all respect i/c necessary fittings (NS) |
| 23 | Providing and fixing of M.S. steel spiral staircase i/c painting complete in all respect.(NS) |
| 24 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work (18.48) |
| 25 | Supply & Fixing Fiber Glass Coated Mesh with thickness of 45 Gsm for the water proofing of terraces, bathrooms , Water tanks, etc. The surface to be levelled, finished, made smooth before fixing of Fiber Glass Mesh, complete in all respect as per manufactures specification and as per directions of Engineer-in-Charge. (13.90) |
| 26 | Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. (13.91) |
| 27 | Providing and fixing of wall paper as per sample & design selected (NS) |
| 28 | 12.5 mm thick cement plaster 1:5 (15.10) |
| 29 | Providing and fixing of Mortize lock i/c screw complete in all respect (NS) Please Enable Macros to View BoQ information |