| 1 | Dismentling of R.C.C including stacking of dismental materials as per direction of sit incharge s no 694 |
| 2 | Dismentling of corrugated AC/MS sheet including purlins battence and vartical suports and including of dismainteld material as per direction of site incharge .S.I no 701 |
| 3 | Dismentling of girders trusses and other steels work including stacking of material as per direction of site incharge. |
| 4 | Excavation of foundation in ordinary soil including lift upto 30 meter and lift upto 1.5 meter and including of excavated earth into the trenches or into the space of the foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed E/I (S.INo.251) |
| 5 | Exvation in soil mixed moorum shingle/black cotton/ kankar requireing the use of special T&P (252) |
| 6 | Concrete with 4 cm gauge stone ballast sand 1.25 FM and cement in proportion of 8;4;1 in foundation and under floor including suplly of all materials labour and tools and plants etc. required for proper comletion of the work , SI NO 281 |
| 7 | M-150 brick work in 1:6 cement and coarse sand in foundationand plinth includin supply of all material labour tools & plants etc. require for completion of the work. S.I no 303 (a) |
| 8 | 12 M.M thick cement plaster 1:3 cement and coarse sand morter over brick work including supply of all material labour and T&P etc. require for proper completion of the work. Below plinth level (S.I No.583) |
| 9 | R.C.C. work with cement approved coarse sand 2 cm. gauge approved stone ballast in proportion of 1:5:3 in lintel of doors and windows excluding its fixing and bending the same with 24 BWG GI Binding wire and including necessary centring and shuttering etc. and also including of the materials required for proper completion of the work binding wire to be supplied by contractor free of cost. (S.I. No. 283) |
| 10 | R.C.C. work with cement approved coarse sand 2 cm. gauge approved stone grit in proportion of 1:1.5:3 in lighter beam of excluding supply of reinforcement and its bending but including its fixing and binding wire and including necessary centering & shuttering etc. (S.I. No. 285 b) |
| 11 | R.C.C. work with cement approved coarse sand 2 cm. gauge approved stone grit in proportion of 1:1.5:3 in raft foundation excluding supply of reinforcement and its bending but including its fixing and binding wire and including necessary centering & shuttering etc. (S.I. No. 287 b) |
| 12 | R.C.C. work with cement approved coarse sand 2 cm. gauge approved stone grit in proportion of 1:1.5:3 in column excluding supply of reinforcement and its bending but including its fixing and binding wire and including necessary centering & shuttering etc. (S.I. No. 288 b) |
| 13 | R.C.C. work with cement approved coarse sand 2 cm. gauge approved stone grit in proportion of 1:1.5:3 in T-beam slab excluding supply of reinforcement and its bending but including its fixing and binding wire and including necessary centering & shuttering etc. (S.I. No. 288 b) |
| 14 | M.S (tor steel or plain) in plain work such as R.C.C or R.B. work including bending for proper shape and including supply of steel & its wastege bend hooks and authorized overlaping shall be measured and including coast of binding wire (S.I. No. 504) |
| 15 | M.S iro work in M.S grill and staire case railling including supply of all labour & material etc. require for complition of the work. S.I. No. 502,(A) |
| 16 | M.S iro work in steel Z section bendow excuding glass panes shall be openable panels and also including wastage fixing proper complition of the work . S.I. No. 502 |
| 17 | Supply and fixing rolling shutters of approved make made 80x125 mm cold rolled M.S. lathe inter locked thorought their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with bracket side guides and arrengements for inside and outside locking with push and pull opreation complete and including the last of tope cover & spring read for proper complete and including the cost of top cover and spring of work. (S.I.520) |
| 18 | Earth filling on plinth includin carted earth from distance 5 km. from the site of work including watring ramming and dressing etc. in 20cm. Layers required for proper completion of the work as per direction of E/I. S.I. No. 253+ cartage. |
| 19 | Sand filling in plinth including supply of necessary quantity of sand including watring dressing etc. for proper completion of the work S.I. No. 255 |
| 20 | M-150 brick work in 1:4 cement coarse sand morter in super structure in one brick thick wall including supply of all material labour and T&P etc. require for proper completion of the work. (S.I. No. 305b+309+310) |
| 21 | M-150 brick work in 1:3 cement coarse sand morter in super structure in 1/2 brick thick wall including supply of all material labour and T&P etc. require for proper completion of the work. (S.I. No. 307+309+310+310 A) |
| 22 | 12 M.M thick cement plaster 1:4 cement and coarse sand morter over brick work including supply of all material labour and T&P etc. require for proper completion of the work. Below plinth level (S.I No.584A) |
| 23 | White washing 3 coats including supply of all material labour T&P require for proper completion of the work S.I. No. 673 |
| 24 | Finnishing walls with water proof cement paint of approvedd make& quality with two coats snowcem over a priming coat of water proofing cement paint of approved make such as super snowcem durrocem supper quality of required shade on undercoated wall surface to give and even shade. ISI. No. 641+642 |
| 25 | Painting or varnishing work in small areas or new wood work withone coat (upto one square meter) ready mixed priming paint or varnish including supply of all materials. Labour tools & paints etc. require for proper completion of the work paint to be used should confirm the ISI No. 641+642 |
| 26 | Providing fixing glass panes 4.5mm thick with putty and brades including cost of labour T&P required for proper completion of the work. S.I.No.806. |
| 27 | 4cm thick plain cement concreat floor with 1:2:4 cement approved coarsand & stone grit laid in panels finishing with 3 mm floting coat of neat cement and marble dust in ratio 5:1 as specific including supply of all materials labour T&P required for proper complition of the work S.I.No.605 |
| 28 | Providing and fixing glass strips of 8mm thick & 3.5 cm deep joints of floor at the time of laying labour T&P completed S.I. No. 631b |
| 29 | Plain cement concreate 1:1.5:3 C/sand 2 cm. Stone grit including supply all materials labour T&P etc. (SI279b) |
| 30 | 2 cm thick plaster in dedo or skirting in 1:2 cement & C/sand including supply all materials labour T&P etc. S.I.No. 597) |
| 31 | Suppling and fixing of 110 mm dia PVC rain water spout pipeincluding L,T&P. |
| 32 | Ferrow cement concreate 1:2:4 with cement C/sand & 2cm gauge stone grit with murga jali including supply of all materials L+ T&P complete for proper completion of work. |
| 33 | making grooves 10 & 12mm wide x 8mm deep in plaster of the wall are sealing verticaly are horzentlly as required. |
| 34 | Supply and fixinf of flush door commercial quality single leaf 35 mm thick |
| 35 | M.S. iron work in heavy size such as transfer building upgate record redes etc. (S.I. 503) |
| 36 | Add extra labour and material for plaster over roush face of one brick thick wall S.I. No. 596) |
| 37 | Providing & fixing of box type fanhook (min 10cm dia) with and including fixing of 12 mm dia cambax in bostion (chaker\\"item\\"NBO 11.22) |
| 38 | Providing & injecting chemicals emulstion for antitermite treatment (chepter 8 item 5 NBO(22.41) b] |
| 39 | Providing, laying, spreading and compacting stone ballast of specific sizes (22.4-53 mm) obtained from approved query sukrut to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming type 'B' screening materials to fill up the interstices of stone dust aggregate, watering and compacting to the required denstity. as per Technical specification clause.4.7/405(3) |
| 40 | Providing & laying of a separation membrane between the concrete slab & the sub-base of impermeable plastic sheet 125 microns thick laid flat without creases. Overlap of plastic sheet is necessary and should be 300mm. The separation membrane is to be stuck to the lower lvl. with patches of adhesives or concrete nails with washer. CH-17NS |
| 41 | Mild steel or iron in plain work such asreinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.(504) |
| 42 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by usingneedle and surface vibrators, levelling to required slope/ camber,finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction ofEngineer-in-charge (Item of joint fillers, sealants, dowel bars withsleeve/ tie bars to be paid separately). DSR16.43.2 |
| 43 | Extra for providing and mixing hardening (TRIMIX) compound of approved quality as per manufacturer's specification in cement concrete. DSR 16.44 Please Enable Macros to View BoQ information |