| 1 | Excavation in trenches not exc 1.50m wide and not exc 1.50m depth for foundation shaft, wells in soft loose soil complete all as specified and directed. |
| 2 | ditto- as per item no.01 here in above but exc. 1.5 m deep and not exc. 3.0 deep. |
| 3 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregates as in foundation fillings and mass concrete complete all as specified and directed. |
| 4 | Returning filling in including spreading levelling and well ramming in soft/loose soil complete all as specified and directed. |
| 5 | Removing excavated materials n ot exc 50 mtrs and deposited where directed at a level not exc 50 mtr where directed not exc 1.50 m above the starting point. Complete all as specified and directed. |
| 6 | Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finished surfaces of concrete complete all as specified and directed |
| 7 | Use and waste form work to sides of column, pillars shape as square, rectangular or polygon for fair finished surfaces complete all as specified and directed. |
| 8 | M&L for reinforced cement concrete Design mix M-25 type B-1 (using 20mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns, etc complete all as specified & directed.(Note Concrete shall be RMC M-25 Design Mix) |
| 9 | M&L for reinforced cement concrete Design mix M-25 type B-1 (using 20mm graded crushed stone aggregate) as in columns, piers, posts and struts complete all as specified and directed.(Note Concrete shall be RMC M-25 Design Mix) |
| 10 | M&L for TMT Bars 10mm dia and over cut to length bent to shape required inculding cranking bending spirally hooping for columns,roofs slab etc and binding with MS wire ennealed not less than 0.9mm dia complete all as specified and directed. |
| 11 | Ditto all as per item No 10 here-in-before but for 5 mm to 8mm dia and over upto and including 10mm dia as in stirrups spacers and binders etc. |
| 12 | S & F steel works in tubular truss, purlins, post etc including special shaped washers complete using ERW or induction butt welded tubes conforming to I.S. 1161 -1979 grade St-240 complete all as specified and directed.Make : JSW/ TATA / Prakash Surya/ Jindal |
| 13 | S & F MS sheet as In base plate, gusset plate etc welded or riveted to steel and gates staircases including holding down bolts, nuts, rivets etc confirming to Fe 410-W(Gde -E-250)quality -A complete all as specified and directed. |
| 14 | S&F Rolled mid steel in rafters,trussed,purlins,crane grantries,rails and fasternings and heavy bracket framing (Beam,tee,angle,channel or flat section) includuing distance pieces,cleats etc (Fe-410-Grade (E-250) quality-A).Complete all as specified and directed.Make : JSW/ TATA / Prakash Surya/ Jindal |
| 15 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 16 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in ridge ,valley gutter etc and fixed with self tapping screws and flat iron complete all as specified and directed. |
| 17 | M & L for preparation of New or previously un-treated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.(Make:- M/s Asian Paints Apcolite Premium Glass Enamel/Nerolac Synthetic High-Glass Enamel/Berger Hi-Glass Luxol). |
| 18 | Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and as directed. |
| 19 | M&L for Brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and as directed. |
| 20 | M&L for Brick work with fly ash old size bricks, straight or curved to any radius in half brick thick walls, built in CM (1:4) complete all as specified and as directed. . |
| 21 | M&L for RCC (Design Mix M-25), type B1, using (20mm graded aggregate as in beams , cantilevers, bressmummers, lintels over 1.5 m span complete all as specified and as directed.(Note Concrete shall be RMC M-25 Design Mix) complete all as specified and directed. |
| 22 | M&L RCC (Design Mix M-25), type B1, using (20mm graded aggregate) as in slab supported on walls, beams and columns in floors , roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.(Note Concrete shall be RMC M-25 Design Mix) complete all as specified and directed. |
| 23 | M&L for form work to chajjas,troughs and similar items including edges complete all as specified and directed. |
| 24 | M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs,landings and similar works : not exceeding 200mm thick (horizontal or sloping) for flat rough finished surfaces of concrete complete all as specified and as directed. |
| 25 | M&L for form work to edges of concrete flats, treads,breaks in floors, window cills, concrete railing, openings in concrete walls, floors and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls,horizontal or sloping and similar work exc 10cm but not exc 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed. |
| 26 | M&L for rendering 10 mm thck in CM (1:4) mixed with liquid WPC on concrete surface in roofs including applying cement slurry @ 3 Kg per Sqm finishing even and smooth without using extra cement ( WPC shall be measured seperately. Complete all as specified and directed. |
| 27 | Supply only Liquid water proofing compound complete all as specified and as directed of as per manufacturer instruction. |
| 28 | M&L for rendering 15 mm thick on fair faces of brick or concrete surface walls, in cement mortar (1:4) , surface finished even and smooth without using extra cement complete all as specified and directed |
| 29 | M&L for rendering 15 mm thick on fair faces of brick or concrete surface walls, in cement mortar (1:6) surface finished even and smooth without using extra cement complete all as specified and directed. |
| 30 | M&L for prepration of new plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed. |
| 31 | M&L for preparation of new plastered/ concrete surfaces of walls to achieve smooth and even surface and applying two coats of cement base paint over and including one coat of primer (up to 4th storey with necessary scaffolding) . |
| 32 | M&L for rendering 10 mm thick on fair faces of brick or concrete surface ceilings, in cement mortar (1:3) surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 33 | M&L three coats of white wash on ceiling on newly plastered surfaces including preparation of surfaces complete all as specified and directed. |
| 34 | M&L for hard core of broken stone or boulder of gauge not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 35 | M&L for 25mm thick PCC (1:2:4) type B1 using 20mm graded stone aggregate as in floor and finished rough to recive the floor tiles etc complete all as specified and as directed. |
| 36 | M&L for 75 mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floors complete all as specified and as directed. |
| 37 | M&L for machine cut kota stone slab (Minimum size shallbe 550mm x 550 mm flooring 18-20mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and Mirror polishing laid over and including screed bed or bedding layer of 20 mm thick in cement mortar (1:6) complete all as specified and directed. |
| 38 | M&L for machine cut kota stone 18-20mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and Mirror polishing set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/colour of tiles over and including 10 mm thick rendering in cement mortar (1:4) as in riser of steps,skirting,dado & vertical surfaces complete all as specified and as directed. |
| 39 | M&L for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in floor/ plinth protection laid in alternate bays finished even and smooth without using extra cement including joints filling by using mastic filling comprising one part of bitumen 85/25 mixed with three parts of coarse sand by weight complete all as specified and directed. |
| 40 | M&L for cutting chases not exc 10 cm girth, pinning in , making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landing , steps cills,sunshades,shelves,lintels etc,and cutting chases for concealed water tubing or concealed conduit wiring,etc,and making good complete all as specified and directed. |
| 41 | Demolition of cement concrete of any description and in any position and Removing excavated material in 100 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 42 | Demolition of reinforced cement concrete of any description and in any position and removing excavated material in 100 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 43 | Demolition of brick work built in cement mortar including all quoin, arches pillars but excluding ashlar facing dressed stone work and precast concrete article complete all as specified and directed. |
| 44 | M&L for providing, cement concrete (1:2:4) type B1 using 20 mm graded stone as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating from work complete all as specified and directed. |
| 45 | M&L for 100 mm thick PCC (1:4:8) type D-2 usinng 40 mm garaded stone aggregate) as in 100mm thick sub base of floor/pathway/in any condition complete all as specified and directed. |
| 46 | M & L for sand filling in floors, 25 mm thick, spread levelled and well rammed including watering and consolidating complete all as specified. |
| 47 | M & L for 16-18 mm Black jet South Granite (of any type) work (table rubbed and polished)in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and directed. |
| 48 | S & F for Framed work Fe 410-W(Gde-E- 250) quality as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors,etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete Fe 410-W(Gde-E- 250) complete all as specified and directed. |
| 49 | S&F in replacement for machine pressed precast concrete interlocking paver block coloured reflective type rubber moulded with pigment any shape and size confirming to IS 15658-2006 of 80mm thickness M-40 grade complete all as specified and as directed.Make:- NITCO/ Mehtab Tiles |
| 50 | Dismantling structural steel work including doors, gates but excluding framed trusses complete all as specified and directed. |
| 51 | M&L for preparation of old painted steel surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed (Make:- M/s Asian Paints Apcolite Premium Glass Enamel/Nerolac Synthetic High-Glass Enamel/Berger Hi-Glass Luxol or equivalent. ) |
| 52 | M&L for sub-main wiring alongwith earth wire of size of 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire, ISI marked FRLS,PVC insulated, multi stranded, copper conductor, single core cable drawn through and incl PVC rigid conduit (medium grade) with all fittings and accessories ISI marked including cutting chases for conduits & sinkings for sunken boxes & making good to walls, floors etc complete all as specified and as directed. Note : Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. |
| 53 | S&F MCB DB SPN 8 Ways double door, IP-42, IK-09 with metel door, rated bus bars, earth bar, neutral links complete incl blanking plates as required & fixed flush to wall/other surface complete all as specified and as directed. |
| 54 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 40 to 63 Amp and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as directed by Engineer-in-charge. |
| 55 | S&F MCB single pole 6 to 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. |
| 56 | S & F for ceiling rose, PVC/polycarbonate insulated body, 3 terminal and 240 volts, ISI marked complete all as specified and directed |
| 57 | Supply and fixing LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 58 | M&L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level) connected to GI wire 4 mm by means of bolts, buts, check nuts and washers of copper including 20mm dia medium grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 15 mm dia charcoal or coke and common salt in alternative layer n.exc 150mm thick compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type C-1 using 20mm graded stone aggregate and RCC cover of size 540 x 540 x 50 mm in RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways and suitable handle made of 10mm dia round bar including aluminium strip of size 25mm x 3mm for extension of earth lead and necessary excavation, earth work in soil/ loose soil and disposal to a distance not exceeding 15 Mtr and necessary connection and testing complete all as shown on electrical plate No 3 and all as specified and as directed. |
| 59 | Supply, laying, jointing and testing in trenches or passing through pipe, 1100 Volts grade XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cable conforming to IS:7098 (Pt-I)-1988, heavy duty with aluminium conductor of cross sectional area 35 Sqmm 3.5 core with necessary fixing arrangements such as lungs, glands and terminal etc. complete all as specified as directed. |
| 60 | Supply, laying, jointing and testing in trenches or passing through pipe, 1100 Volts grade XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cable conforming to IS:7098 (Pt-I)-1988, heavy duty with aluminium conductor of cross sectional area 10 Sqmm 2 core with necessary fixing arrangements such as lungs, glands and terminal etc. complete all as specified as directed. |
| 61 | Supply and laying Sand coarse dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness all complete as specified and as directed. |
| 62 | Supply & lay in replacement unreinforced precast concrete cable cover class LV, Type 1, flat size 250 mm x 150 mm x 40 mm as a cable protection on LT underground cables complete all as specified and directed. |
| 63 | S&F Air Circulator wall fan 600 mm dia with hanging arrangement on wall, pole etc complete all as specified and directed. |
| 64 | S & F Energy saving, environment friendly & robust Mediumbay /Highbay LED luminaire 110 watt, IP 65 with high efficacy with toughened glass/PC complete all as specified and directed. |
| 65 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 66 | S&F MUSHROOM NXT UFO LED BOLLARD 10 W fitting New generation, energy saving, environmental friendly, long life aesthetically designed die-cast aluminium landscape luminaire Based on Dark Sky Concept with mid power LED as light source complete all as specified and directed. |
| 67 | Taking out existing underground LT cable of any sizes by excavation and removing pipe/bricks of any size and relaying in the same trenches or re-routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil complete all as directed by Engineer in Charge . Note: (a) LT cable & joints shall be measured and paid for seperately . (b) Retrieved old serviceable bricks/DCW pipe will be laid in trenches for cable protection. (c) The rates quoted is deemed to be included the cost of Excavation, Returning filling and, earth work labour charges etc. |
| 68 | Supply, fixing and testing straight through joint heat shrinkable type of size 25 to 95 Sqmm x 3.5 core/ 4 core with jointing kit suitable for cable PVC / XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed. |
| 69 | Supply installing testing and commissioning factory made and tested, CPRI approved LT main feeder pillar Outdoor type, weather, vermin proof, free standing floor mounting type mounted of floor/over the duct, with required mounting channel, cable alley for all the feeders, suitable for 440 Volts, 3 phase 4 wire 50Hz AC supply system, conforming to IS - 5039, IP-65 class protection and made of 3.15 mm CRCA mild steel sheet with 50x 50x6mm angle iron frame, hinged doors, front & rear opeing and locking arrangement ( including provision of 65mm Godrej ( freedom) lock with 2 Keys) with necessary bus bar arrangment with insulated Aluminium bus bar 200 Amps rating for phase & neutral, 4 strips, installed on epoxy insulators housed in separated bus chambers covered with heat shrinkable sleeves, and providing extended bus bars with chember arrangement for outgoing cables, copper control wiring of required size for instruments and including the follwing accessories :-Incomming:- MCCB 100 Amp 25 KA 4 Pole, 50 HZ Thermal - Magnetic Release-01 Nos.Outgoing:-(i) MCB 63 Amp 16 KA TPN-02 Nos.(ii) MCB 32 Amp 16 KA SPN-01 Nos.(ii) Digital Ammeter 0-100 Amp with built in selector switch - 01 No.(iv) Digital Voltmeter 0-500 Volt with built in selector switch - 01 No.(v) CT - 100/5 - 1 Set of three.(vi) Indicating lamp (RYB)-03 Nos. |
| 70 | Supply & Fixing visible UPVC sign board of area/ size exceeding 1.80 Sqm and not exceeding 3.15 Sqm each made from 4 mm thick engineering grade plastic (Acralic sheet) having monolithic structure to with stand, temperature variation from cold environment to sweltering hot condition sand to with stand high velocity winds, framed and braced with 40 mm dia PVC pipe best quality to with stand high velocity wind pressure, with height of bottom of board should be 40-90 cm above the ground level with best quality structure including excavating in post holes of size 30cmX30cmX45cm and embedded in PCC (1:2:4) type B1 using 20 mm graded stone aggregates and making plinth around frame of width 600 mm and length as required, including providing and applying weather resistance coating , providing and painting of new numerals/ alphabets with retro reflective tape cutting as computer plotter etc complete all as specified and directed. |
| 71 | Supply & fixing outdoor type, LED Sign Board P10 Advertising Digital Display Board for Main Gate, rectangle type, size of board (H)X600 (W)X4000 mm, Color- (Red/Green/White/RGB) ,Mounting suitable for Wall Mount/Hanging Mount, Programming: Wifi,Power Supply: 100-240V AC 50/60Hz, Lamp Life: 20,000+ Hours, electric connection complete all as specified and directed . |
| 72 | Material and labour plain cement concrete 1:3:6 type C-2 (using 40 mm graded mechanically crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 73 | M&L for Brick work with flyash bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 . |
| 74 | M&L Brick work using old size bricks with flyash bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. |
| 75 | M&L PCC type B-0,1:2:4 (12.5mm graded stone aggregate) as in coping, benching & kerbs including use and waste of form work where necessary coping, side kerbs, mud stops etc complete all as specified and directed. |
| 76 | Supply & Fixed for 100 mm bore cast iron spun pipe in any length including jointing with cement joint fixed to wall or laid in floor etc.complete all as specified and directed. |
| 77 | Supply & Fixed cast iron spun Bends (any radius) size 100mm bore complete all as specified and directed. Please Enable Macros to View BoQ information |