| 1 | Rough excavation not exceeding 1.5 m deep and getting out in hard/dense soil. |
| 2 | M&L for hard core of gauge n.exc 63mm (broken stone and boulders), deposited, spread and levelled in layers nexc 15 cm thick, watered and rammed to a true surface. |
| 3 | Exacavation in trenches , n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of pipes or for run lead joint and getting out in hard/dense soil. |
| 4 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm. |
| 5 | Removing excavated soil n.exe 50Mtr & depositing where directed at a level n.exe 1.5m above the starting point |
| 6 | 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV 63 mm stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches. |
| 7 | 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4(PN16) UV 40 mm stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches. |
| 8 | PP-R Gate valves 63 mm (brass insert) as per requirement of the site |
| 9 | S&F PP-R Gate valves (brass insert) 40 mm as per requirement of the site |
| 10 | Supply & Fix float valve assembly complete with PVC ball valve & flynut screwed for iron pipe of 40 mm bore complete all as specified and as directed by Engineer in charge. |
| 11 | S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 5000 Ltr capacity hoisted and fixed in position including tank nipple and other connected fittings all as specified and directed(Total Capacity = 3x5000 i.e 15000 Ltrs) |
| 12 | M&L for 125 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) cement concrete as in base coat and pavings etc complete all as specified. |
| 13 | M&L for 75 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floor finishes. |
| 14 | Supply,lay.testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade,multi stranded, cross-sectional area 10 Sqmm 4.0 core complete including taking down old all as specified and directed by engineer in charge. |
| 15 | Supply and fixing pole docorative KP - 12024-400 Causeway Midi Lighting Pole 4.0 m and Pole type P13 with pole finish of Anthractic Grey. The control gear tray is prewired with MCB,Terminal connectors for loop-in/ loop out arrangement.Base plate made of steel grade E25 & foundation Bolt of grade 4.6.Including disconnect of electric connection, dismantiling of existing pole with light fitting and after complete the electric connection as directed by Engineer - in - charge. |
| 16 | Supply and fixing Nene Bracket size of 1.23 feet and height of 375 mm with pole finish of Anthractice Grey all as directed and as specified by Engr in Charge . |
| 17 | Supply and fixing Genesis KL - 25435 E27-D Holder Max.30W LED With dimension 480X417X850 and mounting model of D2 ,product of RAL 7016 Anthracite Grey IP 65 all as directed and as specified by Engr in Charge . |
| 18 | S&F LED Bulb 17 watt cat part no LED CLASSY 17W 2 STAR E27 WW V3 LAMP complete all as specified and as directed by engineer-in-charge. |
| 19 | M&L for submain wiring in steel conduit alongwith earth wire connection tapping from the line / connecting up from the junction box to the fitting with the two run of PVC insulated copper conductor, single core1.5 sqmm FRLS cable for phase and neutral and one run of 1.5 sq mm FRLS cable of green colour for earting connected to earth dolly all as specified and directed.Note:-Two run of cable copper conductor 1.5 sqmm and steel conduit(20mm dia) shall be measured as one unit length. |
| 20 | S&F High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 50 mm bore. |
| 21 | Supply & Fix street light Pole boxes of size 6x8x4 inches for MCB Sliding cover boxes,weather dust rain guarded cable entre and exit arrangement of suitable size of housing of with 01 No MCB SP 6/10 Amps Including Bolts & nuts Clamps for fixing to pole, painting a coat of synthetic enamel paint including termination of cable of size 16 to 35 sqmm 2 Way 4 connectors Each in each boxes all as directed by Engineer - in - charge ( Sintex, Hensel) |
| 22 | Supply and fixing in repair MCB 5- 32 Amp SP 240V, 10KA 'C' complete with connection testing and commissioning all as directed and as specified. |
| 23 | M&L PCC (1:3:6) type C-2 using (40mm) graded stone aggregates as in foundation filling , mass concrete and grouting for nuts and bolt (for foundation bed concrete in poles or any other directed site) . |
| 24 | Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized GI wire 4.0 mm as earthing lead by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and provision of concrete pit in PCC (1:3:6) type C1, pre-cast including RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm, reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways, one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil, dismantling and taking out old earthing plate and necessary testing complete all as shown on electrical plate No 5 of SSR Part –I (2009). |
| 25 | Supply, installing,Testing and Commissioning outdoor type timer panel 6 KW including digital time switch 24 Hrs,contactor 65 A TP,MCB 63 A TPN.Make Havells Cat Part No IHXTS09120 including complete electric connection all as specified and directed by engineer in charge. Please Enable Macros to View BoQ information |