| 1 | Dismantling existing plaster including disposal of refuse as directed by the Engineer-in-charge with in a distance of 60 metre ¼200ft.) SI no. 15.56 |
| 2 | 12 mm plaster with 1:6 cement and course sand as per dsr 13.4.2( 1cement:6 course sand) |
| 3 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 4 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete. As per DSR 13.80 |
| 5 | Finishing walls with Acrylic Smooth exterior paint with Silicone additives of required shade 13.112.1 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surfac |
| 6 | Dismantling cement concrete or brick or granolithic floors, including base concrete and including stacking of dismantled materials as directed by the Engineer-in- charge with in a distance of 60 metres ¼200ft½ |
| 7 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.. ref to DAR 11.38 |
| 8 | providing and fixing 18mm thick gaing saw cut mirrir polished premodueld and pre polished machine cut for kitchen plateform as per dsr 8.2.2.2 mm thick |
| 9 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete 11.41.2 600mmx600mm |
| 10 | Dismantling brick work or stone work in lime or cement mortar and including stacking of materials as directed by the Engineer-in- Charge with in a distance of 60 metres ¼200 ft.) |
| 11 | Brick work with common burnt clay (non modular) brick of class -150 in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure above plinth level and upto floor five level. |
| 12 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610X510 mm bowl dept 200 mm as |
| 13 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillartaps, 32 mm C.P. brass waste of standard pattern, including painting of fittingand brackets, cutting and making good the walls wherever require:17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 14 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required RAMP and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 15 | providing and fixing T- iron frame door windows and ventilators weldid section including fixing of necessary hings butts and scresw as per dsr 10.25.1 |
| 16 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.10.5.1 Using M.S. angels 40x40x6 mm for diagonal braces |
| 17 | Providing and fixing factory made PVC door frame of size 50x47 mm with a wall thickness of 5 mm made out of extruded 5 mm rigid PVC foam sheet mitrid at corners and joined with 2 no of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door profiles to be reinforced with 19x19 mm MS square tube of 19 gauge EPDM rubber gasket weather seal to be provided through out of frame the door frame to be fixed to the wall using MS screws of 65/100 mm size complete as per manufactures specification and direction of Engineer-in-charge. |
| 18 | Providing and fixing factory made panel PVC door shutter consisting of frame maid out of MS Tubes 19 gauge thickness and size of 19 mm, 19 mm for styles and 15x15 mm for top and bottom rails MS frame shall have a coat of steel primers of approved make and manufacture MS frame covered with 5 mm thick heat moulded PVC channel of size 30 mm thickness 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tappered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapperd on both sides to form lock rail top bottom and lock rails shall be provided either side of the panel 100 mm thick 20 mm wide cross PVC sheet be providedas gap insert for top rail and bottom rail paneling of 5 mm thick both side PVC sheet to be fitted in MS frame welded/ sealed to the styles and rails with 7 mm thick x 15 mm widePVC sheet beading on inner side and joined together with solvent cement adhesive an additional 5 mm thick PVC strip of 20 mmm width is to be stuck on the interior side of C channel using PVC solvent adhesive etc complete as per direction of En-in-charge manufactures specification and drawing. |
| 19 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30mm thick including ISI marked Stainless Steel butt hinges with necessary 9.21.2 |
| 20 | Distempering with 1st quality acrylic distemper, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre, of approved brand andmanufacture, including applying additional coats wherever required, toachieve even shade and colour.13.81.1 *2 for 2 coat |
| 21 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 22 | Providing & fixing glass panes with putty and glazing clips in steel doors, vwindows, clerestory windows, all complete with :10.30.1 4 mm thick glass panes |
| 23 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 24 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 110 mm diameter |
| 25 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamp 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm dia |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamp 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step CPVC solvent cement andtesting of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 20 mm dia |
| 27 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 28 | septic tank with sock pit Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 2.6.1 All kinds of soil |
| 29 | pcc work for septic tank with 1:3:6 cement concreate 1 cement: 3 course sand : 6 course agg. All waork upto plinth level 4.1.5 |
| 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 31 | RCC work for septic tank with 1:1.5:3 cement concreate 1 cement: 1.5 course sand : 3 course agg. All waork upto plinth level 4.1.2 |
| 32 | mild steel or iron work in rcc structure for rainforecement work . |
| 33 | 12 mm cement plaster of mix : 13.4.1 1:4 (1 cement: 4 coarse sand) |
| 34 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate |
| 35 | Honey-comb brick work 10 / 11.4 cm thick with common burnt clay bricks of class designation 7.5 in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand). 6.23. |
| 36 | supply and fixing C.I. cover without frame for manhole 50cm dia 58 kg wt. |
| 37 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 2.10.1 All kinds of soil |
| 38 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 39 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 40 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 75 mm diameter As per DSr no. 12.41.1 |
| 41 | Providing and fixing Qrissa pattern W,C. PAN size 580x540 as per dsr 17.1.1 |
| 42 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 17.7.1 |
| 43 | Supply and fixing of Looking Mirror with H.B. 600x450mm complete with hard board |
| 44 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 45 | Supply of C.P. Brass bib cock long body |
| 46 | Supply of C.P. Towerl Rail |
| 47 | Supply of C.P. Jali 6\\" dia |
| 48 | Dismantling of bathroom mosic plaster, dado floor & all other damaged W/s sanitry fittings complete Please Enable Macros to View BoQ information |