| 1 | Excavating in post holes each n exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceedings 25cm watering and removing surplus soil to distance n exc 50 m and making good surfac in soft/loose soils |
| 2 | M&L for PCC 1:3:6 type C-2 (40 mm graded agg) for post holes complete all as specified and dircted. |
| 3 | M & L for brick work with Cement Mortar1:6 using sub class 'B' bricks,old size , straight or curved on plan exceeding 6 m mean radius all as specified and directed. |
| 4 | Supply and fixing PVC sheet consisting of 5mm thick light colour PVC sheet inclusive of fixing on PVC frame /Aluminium frame at site etc complete all as specified and as directed by Engineer-in- charge. |
| 5 | S&F powder coated not less than 50micron Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified |
| 6 | S&F 4.8 mm thick sheet glass, ordinary quality and glazing in Aluminium door with solar control files 50 micron in any size each pane. |
| 7 | S&Fsteel work as in posts and struts , flats in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 8 | Dismantling and Re-Fixing only chain link fencing incl line wires, any mesh, size and type to any type of standereds, rails, straining blots, etc. incl provn of binding wire. |
| 9 | Supply & Fix chain link MS galvanised fencing any size (75x75mm)or any type complete. |
| 10 | S&F 2mm thick fibre glass reinforced translucent plain sheeting with side lap fixed with srew. |
| 11 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 12 | M&L hard core of broken stone of gauge n. exc. 63mm; deposited, spread and levelled in layers n. exc. 15cm thick watered and rammed to true surface complete all as specified and directed by Engineer-in-Charge. |
| 13 | M&L 75mm thick PCC (1:3:6) C-2 using 20mm graded stone aggregate as in sub base of floor, plinth protection etc. finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 14 | M&L Endura chequered tiles 30cmx 30cmx 10mm thick,set, jointed & pointed in neat cement slurry in floors with grey cement and pigments over & including 15mm thick screed in cement mortar 1:6 |
| 15 | M&L for Roof trusses (framed), trussed, Rolled sections as in main and cross beams, hip and jack rafters, purlins,post, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) includingdistance pieces, cleats etc.Fe 410 -W (GdeE- 250) quality A all as specified and directed. |
| 16 | S&F Pre-painted galvalume aluminum Zinc coating GI based Corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 17 | M&L for Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described, and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified. |
| 18 | M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates, 75mm thick in foundation filling and mass concrete. |
| 19 | M&L for machine pressed precast concrete interlocking paver block with gray cement and no pigment, any shape and size confirming to IS- 15658 -2006 of 80mm thickness, M-40 Gde,Over and including 20mm thick layer of sand complete all as specified and directed. |
| 20 | M&L for 100mm thick PCC (1:4:8) Ty D2 as in sub base over rammed earth. |
| 21 | M & L Virified Ceramic dark shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match 15mm thick screed bed in CM 1:6 including pointing in coloured cement to match the shade of tiles. |
| 22 | M&L for Powder coated aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beadingscrews etc. complete all as specified |
| 23 | M&L for Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat forfixing etc. complete all as specified |
| 24 | M&L for PVC insulation tjickness of PVC insullation panels 40mm with EPS stuck to 1mm plain PVC sheetsuitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing directed by Engineer-in- Charge |
| 25 | M & L for 10 mm thick internal rendering in cement mortar 1:6 on fair face of brick walls/ concrete surfaces & finished even and smooth without using extra cement, complete all as specified. |
| 26 | M&L for brick work with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls with old size bricks, built in cement mortar 1:4, complete all as specified. |
| 27 | S&F Modular Cabinet Kitchen accessories of Stainless Steel grade-304,6mm size rod thickness including :-(i) Perforated Cutlery basket, (ii) Grain trolley, (iii) Thali basket, (iv) Cup & saucer basket, (v) Glass basket, (vi) Plate basket, (vii) Premium magic corner (viii) Oil Pull out Tray ( Triple basket layer) , (ix) Dust bin, (x) Cleaning kit rack of size as per site requirement all spd and directed by Engr in charge |
| 28 | S & F 50 mm dia Galvanised Iron steel tubing, medium grade as in spout in short length, complete all as specified. |
| 29 | S&F in Soft closing ball bearing telescopic channel of size 22 inch long fixed with screws in cupboards incl all fittings complete all as spd and directed by Engr in charge.Note : Runner/ Channel should be SS 304 grade and load capacity should not be less than 45 kgs |
| 30 | S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2 and esistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/Bathroom/Toilet/Kitchen and Cabinets. |
| 31 | S&F factory made uPVC white colour three track three panels sliding window with flyproof S.S. wiremesh ( Two nos. glazed & one no. wiremesh panels ) upto 1.50m ht made of big series frame 116 x 45mm & sash 46 x 62mm both having wall thickness of 2.3 + 0.20mm and single glazing bead/ double glazing beading of appropriate dimension ( Area of window upto 2.0 sqmtr) comprising of uPVC multichambered frame and mullion (wherevr required) extruded profile duly reinforced with 1.60 +0.20mm thick galvanised mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropraiate dimension, EPDM gasket, G.I. fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless screw etc.Profile of frame & sash shall be miterd cut and fusion welded at all corners, mullion (if reqd) shall be also fusion welded including 5mm thick toughened glass and SS wire mesh fixed and drilling holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of reqd size and approval quality, all complete as per approved drg and direction of Engr in charge. Note: For uPVC frame, sash and mullion extruded profiles ,minus 5% tolerance in dimension i.e depth and width of profile dimension in higher side shall be acceptable but no extra payment on this account shall be made |
| 32 | M&L for 50mm thick PCC 1:3:6 type C2 using 20mm graded stone agg as in sub base complete all as specified.. |
| 33 | M&L for 22 to 25mm chequered ultra tiles over 15 mm thick screed bed in cm 1:6 and jointed and pointed in white cement mixed with pigment to match the shade of tiles of flooring all as directed. |
| 34 | M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar (1:4) complete all as specified and as directed. |
| 35 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness ( below or above ground level). |
| 36 | M&L 25mm thick cement concrete type B-O, 1:2:4 (12.5mm graded agg ) as in sub flooring. |
| 37 | M&L for Non-skid ceramic tiles, coloured, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified. |
| 38 | All as per item No 37 above but as in skirting over rendering 10mm thick in cement mortar 1:4. |
| 39 | S & F RMP sheeting 1.5 mm thick with 1.5 corrugation side lap fixed with coach screw and PVC washer in roof, wall etc all as specified and directed. |
| 40 | M & L 75 mm thick sand filling under floors or in foundations including watering and consolidation. |
| 41 | S & F Expanded metal n exc 4 kg weight per square meter, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members all as specified and directed. |
| 42 | M&L for rendering 15mm thick in CM 1:4 on fair faces or other than fair faces of brick work or concrete surfaces firnished een and smooth without using extra cement up to hieght of four storey ,including scaffolding complete. |
| 43 | Supply and fixing LED post top light made in die cast aluminium housing and spun aluminium top reflector with decorative PMMA diffuser having IP 65 protection complete of 45/50 watt including making necessary electrical connections and fixing arrangement etc all as required at site and directed by Engineer-in-Charge. |
| 44 | Supply and fixing LED bollard light aluminium extrusion, opal, polycarbonate diffuser for spot free lighting having IP 65 protection complete of 45/50 watt including making necessary electrical connections and fixing arrangement etc all as required at site and directed by Engineer-in-Charge. |
| 45 | S&F in repair twin core cable 6 Sqmm PVC insulated heavy duty 1100 volts grade, aluminium conductor drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit 25mm dia in ground including burial in ground as required and directed alongwith conduit accessories all as specified and directed. |
| 46 | Supply and fix MCB DB SPN 4 way Horizontal, IP-43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar,neutral link earth link complete all as directed by Engineer-in-Charge. |
| 47 | S&F MCB SPN 32 Amps 240 volts 10 KA 'C' curve and making necessary electrical connections all as specified and directed. |
| 48 | S&F MCB SP 6-32 Amps 240 volts 10 KA 'C' curve and making necessary electrical connections all as specified and directed. |
| 49 | M&L tube light grade galvanised with fittings complete to walls and ceiling or laid in floors 40mm dia. |
| 50 | M & L for point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box/ M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate/3mm thick laminated top sheet cover for housing switches,socket out let and fan regulators etc complete for the followings:- |
| 51 | One light/fan point controlled by one switch. |
| 52 | One 3 pin 5 Amps socket outlet point controlled by one switch on independent board with 1.5 sqmm. |
| 53 | All as per item No-50 but with 2.5 sqmm single core FRLS copper cable. |
| 54 | All as per item No-50 but with 4 sqmm single core FRLS copper cable. |
| 55 | S&F switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 56 | S&F Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 57 | S&F switch Modular type 16 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 58 | S&F Modular socket outlet 6A/16 Amp 2/3/5 pin 2 module complete all as specified and directed by Engineer in charge. |
| 59 | M&L for breaking old existing wall and making a provn for fixing of 160 mm Electric Chimany pipe including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed. |
| 60 | Supply and Fixing wall mounted angular Electric chimney black colour of suction power not less than 1050 cum/Hr,Al casette with stainless steel outer layer ,touch control panel,3 speed motor with 250 watt with decorative smart cooker hood SS and glass ,energy efficent Led light with digital display , including ducting not less than 12 feet as per site required complete. |
| 61 | Supply and fix wall mounted fan 400mm size, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord (two) system complete all as specified and directed. |
| 62 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2400 systems lumen output with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>70, Power Factor > 0.90, THD< 10%, colour temperature-6500K, surge protection 2.5 KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed. |
| 63 | Supply,installation, testing and commissioning instant electric water heater with heating element of capacity 3 ltrs complete with all accessories such as safety valve, thermostat, NRV, connection piece etc and connecting with water mixture complete with all other accessories reqd for making water connections all as specified and directed. |
| 64 | S&F sub main wiring with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multi stranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multi stranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls/conceled on wall as required at site including making electrical connections complete all as specified and directed. |
| 65 | Supply and fix electric water heater vertical storage type of capacity 25 ltrs white coloured having anti rust coating metal body with SS tank and heating element 2 KW, 5 star rated complete with all accessories such as safety valve, adjustable thermostat,auto cut off system, NRV, two Nos SS braided pipe of 12 mm (internal) heavy duty suitable for hot/cold water of suitable length as per OEM with brass nuts and rubber washers etc. and fastners (04 Nos) for mountting of geyser at suitable height and making necessary water connections from existing pipe line including all connected items required at site complete all as specified and directed.Make :V Guard/Havells/Recold. |
| 66 | M&L for providing PCC foundation of cement concrete, rounded or chamferted on edge of type B1, 1:2:4, (20mm graded aggreggate) complete all as required at site. |
| 67 | M&L ceiling rose , PVC polycorbonate,isolated body. complete all as specified. |
| 68 | Supply and fixing ceiling fans three blade, Robust and reliable inverter motor (brush less DC Motor) powered by BLDC technology, BEE 5 star rating for energy saving, down rod, electonic regulators as per site requirement, remote of ceiling fan & accessories, rated Air delivery >220 cum/min, service valve > 6, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length, complete all as directed. |
| 69 | M & L for Point wiring (concealed) complete with 2.5 sqmm single core PVC insulated FRLS unsheathed cable 1100 volts grade with multi stranded copper conductor drawn through in and including non metallic medium grade rigid PVC conduit, ISI marked not less than 20 mm dia including all accessories concealed in wall by cutting chases and including provision of 2.5 sqmm PVC insulated copper cable FRLS unsheathed as earth continuty conductor including fabricated branded modular metal flush box duly make embossed, concealed in walls and with suitable modular inner and outer plate for housing switches , socket out let etc, complete all as specified and as directed. Note for Item No 52 & 53: (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC casing&caping/Existing conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above.(iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC. |
| 70 | Schedule of Credit Please Enable Macros to View BoQ information |