| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead |
| 2 | 12 mm Plaster with 1:6 (C:C/Sand) on Fair face (outer surface) |
| 3 | P/F of 6 mm Thick glazed Tiles 300x300 in Flooring |
| 4 | Providing and fixing tiled false ceiling of specified maerials of size 595x595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanised steel sections (galvanised @120 grms/sqm, both side inclusive) consisting of maijn T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\"12.5mm thick square edge PVC laminated Gypsum Tile of size 595x595mm made of Gypsum plastterboard, manufactured from natural gypsum as per IS 2095 part 1 and laminated with while 0.16mm thick fire etardand PVC film on the face side and 12 micron metalized polyester on the back side with all edges seated with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 5 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 6 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primerhaving VOCcontent less then 50 grm/lit |
| 7 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Wood Work |
| 8 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Steel Work |
| 9 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 10 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm |
| 11 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) : For fixed portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 12 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge.: Pre-laminated particle board with decorative lamination on both sides |
| 13 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes |
| 14 | Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks,drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge |
| 15 | Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc.with auto closing spring loaded hinges (hydraulic type) etc. completen as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) |
| 16 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.:125 mm |
| 17 | Rubbing & POLISHING of existing OLD tarrazo floor |
| 18 | Electric Work : Wiring for light point / fan point / exhaust fan point / call bell point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required. Group B |
| 19 | Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 20 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. :1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 |
| 21 | Supplying and fixing extra down rod of 10 cm length G.l. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 22 | Supply and fixing of 2' x 2' , 36 Watt to 46 Watt, indoor recess / Surface mounting LED Square fitting for Armstrong ceiling having Powder coated CRCA housing body diffuser of special polycorbonate meterial and driver set,complete in all respects. 70 mm height with fully covered diffuser type, system lumens, 100 lm/W, PF>0.95, THD<10%, at full load, CRI>80, with 3 year warranty. CAT AAA |
| 23 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 24 | 3 pin 5/6 A socket outlet |
| 25 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 26 | 2 X2.5 sq. mm + 1X2.5 sq. mm earth wire |
| 27 | Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) |
| 28 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 29 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. Please Enable Macros to View BoQ information |