| 1 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out soft/loose soil |
| 2 | Taking down chowkhats or frame exc 1.5 sqmtr but n.exc 4 sq m(without taking off shutters from frames), complete all as specified and directed. |
| 3 | Taking down chowkhats or frame n.exc 1.5 sqmtr (without taking off shutters from frames), complete all as specified and directed. |
| 4 | Demolation of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing the debris outside the defence land complete all as specified and as directed |
| 5 | Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) complete all as directed. |
| 6 | Demolition of stone, brick/PCC block masonry work built in cement mortar complete all as directed. |
| 7 | Dismantling timber in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 9 | Dismantling of iron/mild steel framed trusses each not exceeding 10m span. |
| 10 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets. |
| 11 | Dismantling plain or corrugated steel sheeting any thickness, complete all as specified and directed. |
| 12 | Dismantling timber scantlings 40 sq. cm and over in section, in any position, unframed work |
| 13 | Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 14 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. |
| 15 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 16 | Excavating over areas, n exc1.5 m deep and getting out in hard/dense soil |
| 17 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads |
| 18 | M & L for 5mm thick Prelam PVC sheet in strips & channel feathered at the edgesfor fixing on Solid/hollow PVC Wall Lining, Insulated PVC Wall Lining, and Solid/hollow PVC Partitions all as specified and directed. |
| 19 | M & L for framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to beprepared for hanging or sliding with and including either hooks and hinges or steel hangingdoor fittings (exclusive of steel sheeting or other covering, running rails and guides) andhanging; also fastening and fixing comple, grade Fe-410W (Gde-250) quality -B complete. |
| 20 | M & L for plain cement concrete Type - D2 (1:4:8) ( using 40mm graded stone aggregate) as mass concrete complete all as specified and as directed |
| 21 | M & L for Preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over coat of red oxide zinc chrome primer complete all as specified and directed. |
| 22 | M & L for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. |
| 23 | M & L for RCC 1:2:4 Type B1 (nominal mix), (using 20mm graded aggr) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete. |
| 24 | M&L for 100 mm thick cement concrete 1:4:8 type D2 ( using 40 mm graded stone aggregate) as in base coat. |
| 25 | M&L for 75 mm thick 1:3:6 type C2 ( using 40 mm graded stone aggregate) as sub base, plinth rotection./paving/footpath finshed the top surfaces even & smooth w/o using extra cement. |
| 26 | M & L for Second class hard-wood in scantlings, clean sawn timber unframed and fixed. |
| 27 | M&L second class hard wood plain fillets.square, rectangular or triangular in section, clean sawn, sectional area exc 13 sq cm and n exc 25 sq cm secured with nails |
| 28 | M&L second class soft wood plain fillets.square, rectangular or triangular in section, clean sawn, sectional area exc 13 sq cm and n exc 25 sq cm secured with nails |
| 29 | M&L for Rendering 15 mm thick CM (1:6) on fair faces in two layers of concrete surfaces of wall , finshing the surface even and smooth without using extra cement complete. |
| 30 | M&L for 100mm thick PCC 1:3:6 type C2 40mm graded aggregate as in plinth protection/paving/footpath, flooring, complete all as specified and directed. |
| 31 | M&L for 10mm thick rendering in CM (1:4) over block/concrete wall surfaces finished fair and even and smooth w/o using extra cement. |
| 32 | M&L for 40mm thick PCC type B-1, 1:2:4 (20mm graded aggregate) as in floor, complete all as specified and directed. |
| 33 | M&L for 4mm thick plywood, (3 Nos of ply)grade BWR, type BB, fixed with nails to timber framework in ceiling |
| 34 | M&L for 5 mm thick rendering in CM (1:3) over block/concrete wall surfaces finished fair and even omplete. |
| 35 | M&L for 6mm thick plywood, (5 Nos of ply)grade BWR, type BB, fixed with nails to timber framework. In walls |
| 36 | M&L for 75mm thick PCC 1:3:6 type C2 40mm graded aggregate as in plinth protection/paving/footpath, flooring, complete all as specified and directed. |
| 37 | M&L for broken stone or boulder hardcore of gauge n exe 63mm deposited, spread and levelled in layers n exe 15cm thick, watered and rammed to a true surface. |
| 38 | M&L for MS TMT bars 10mm dia and over, cut to lenth, bend to shape required, including cranking, bending, sprially for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. |
| 39 | M&L for prep of newly plastered surfaces of walls and applying two coats of OBDover a coat of primer complete all as specified and as directed complete. |
| 40 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint, complete all as specified and directed. |
| 41 | M&L for preparation of new plastered/concrete surfaces of walls and applying two coats of oil bound distemper over one coat of primer, etc complete all as specified and directed. |
| 42 | M&L for prepration of new wooden surfaces exc.10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 43 | M&L for Providing precast cement concrete type C1 1:3:6 (20mm graded stone aggregate) solid building blocks or slabs exc 10cm thick (with plain or interlocking joints as directed)setting in mortar 1:6 ,complete, in walls |
| 44 | M&L for rendering 10 mm thick plaster on other than fair faces of brick/concrete surfaces in CM (1:6) on wall surface, finished even and smooth without using extra cement. |
| 45 | M&L for rendering 15 mm thick plaster on fair faces of brick/concrete surfaces in CM (1:4) on wall surface, finished even and smooth without using extra cement. |
| 46 | M&L for two coats of cement base paint on new plaster wall surface including preparation of plastered surfaces complete all as specified and directed. |
| 47 | M&L for Virified Ceramic Dark shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed with CM (1:6) 15mm thick for laying floor tiles complete all as specified and directed. |
| 48 | M&L for Virified Ceramic light shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed with CM (1:6) 15mm thick for laying floor tiles complete all as specified and directed. |
| 49 | M&L for Walling of random rubble uncoursed, well bonded bedded and solidly hearted built in CM 1:6 (below ground level) complete all as specified as directed. |
| 50 | M&L Plain cement concrete (1:3:6) type C-2, using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified. |
| 51 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 52 | Materials and Labour for precast cement concrete block masonry (1:3:6) type C1 using 20 mm graded stone aggt with solid blocks, exc10 cm in width, set in cement morter (1:6) in wall complete all as specified and directed. |
| 53 | Preparing of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 54 | S & F 30 mm thick flush shutters,solid core construction with block board core and plywood face panel, commercial type on both sides, complete all as specified and directed. |
| 55 | S & F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 56 | S & F plain CGI sheet number plate(20cm x 20cm) for boundary pillars .All as per specification and direction by engr in charge. |
| 57 | S & F plain Sheet glass 3mm thk , ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane |
| 58 | S & F125mm thick plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length andgirth as fixed) complete. |
| 59 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws as specified. |
| 60 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 61 | S&F 2nd class HW plain solid straight chowkhats and frame wrought framed rebated on the soild rounded or chamfered put together with glue pinned at joints, complete all as specified and directed. |
| 62 | S&F 35mm thick 1st class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats |
| 63 | S&F for 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed , complete all as specified and directed. |
| 64 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening (Beam, tee, angle, channel or flat sections) icluding distance pieces, cleats etc, complete all as specified & directed. |
| 65 | Supplied only liquid WPC |
| 66 | Supply and fix Aluminium anodized barrel tower bolts of extruded section, 150 mm long, complete all as specified and directed. |
| 67 | Supply and fix Aluminium handles, cast type, anodized, 150 mm size , complete all as specified and directed. |
| 68 | Supply and fix mild steel butt hinges, medium weight, cold rolled 100 mm size , complete all as specified and directed. |
| 69 | U & W of form work to soffits or suspended slabs such as roof slabs, landings and similar work, n exc 200 mm thick (horizontal or sloping) rough finished flat surfaces of concrete. |
| 70 | Flue pipes of mild steel sheet 100mm dia, black, in suitable lengths as approved by the E.I.C. fixed to walls. |
| 71 | Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc) |
| 72 | M/L for point wiring in casing caping with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl casing caping with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: One light/fan point controlled by one No piano type switch 5 Amps single pole one way |
| 73 | One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board. |
| 74 | One socket outlet 5/3 pin 6 AMPS controlled by one switch on the independent board. |
| 75 | All as per item No 1 above but one 3 pin socket out let 15/16 Amps with three Nos single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase, neutral & earth continuity conductor. |
| 76 | S&F Switch Piano Flush button single pole one way 5/6 Amp. |
| 77 | S&F Switch Piano Flush button single pole one way 15/16 Amp. |
| 78 | S&F socket outlet 2 in 1, 3 pin & 2 pin, 5/6 Amp, 240 volt. |
| 79 | S&F socket outlet 2 in 1, 3 pin & 2 pin, 5/6 Amp and 15/16 Amps , 240 volt. |
| 80 | S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door (Metallic) type including taking down old unserviceable MCB DB with MCBs. |
| 81 | S&F ceiling rose surface bakelite 65mmx50mm 100watt three terminal. |
| 82 | S&F MCB SPN 40 Amps 240 volts 'C' series, 10 KA, 50 Hz. Make:- As approved Make of DB |
| 83 | S&F MCB SP 5 to 32 Amps 240 volts 'C' series, 10 KA, 50 Hz including connection in the DB and testing/commissioning. Make:- As approved Make of DB |
| 84 | Supply and fixing LED lights fitting 1x 18W, 4 feet, 220V,AC decorative box type with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 85 | Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. |
| 86 | Supply and fixing LED light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 87 | Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduit grouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete including taking out old unserviceable earthing materials all as specified and as directed. |
| 88 | F LED lamp 9 Watt, White, B-22 cap, (Pin type), 230W, PF not less tha 0.85 (min). Make- Havells/Crompton/Syska |
| 89 | Supply and fixing lamp holder, insuleted body with pack plate suitable batten fitting on wall duly grouted/fixed in solid block wall or on wooden board complete all as specified and directed. |
| 90 | Supply and laying or fixing or passing through pipeXLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade of size 10 sqmm 2 core complete all as specified and directed by Engineer in charge. |
| 91 | S&F high density polyethylene pipes (HDPE) of pressure rating 6Kgf/cm2 laid in trenches of size 15 mm dia all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |