| 1 | Dismantling plain or corrugated steel sheeting, any gauze, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed. |
| 2 | S & F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 3 | S & F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | Dismantling boarding/wall panelling any description fixed in any position with nails complete all as specified and directed. |
| 5 | M&L 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed in repair with screws to timber frame work complete all as specified and directed. |
| 6 | Dismantling wrought iron or mild steel work of any description not other wise provided complete all as specified and as directed. |
| 7 | M&L Rolled MS sections as in framing (roof trusses,purlins)for cladding, glazing and the like including door frames/chowkats, fixed with angle cleats and connecting plates of grade Fe 410-W (Gde E-250), etc complete all as specified and directed. |
| 8 | S & F MS work framed brackets of angles or tees with web and flanges cut to shape drilled and couter sunk for screw, including bending and welding angles, as necessary, gusset plates, riveting etc. n.exc 10 kg each brackets conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed. |
| 9 | Dismantling of wall and ceiling boards(fibre, pulp,insulation etc) or insulation board/slabs/blankets any thickness including cover fillets complete all as specified and directed. |
| 10 | M & L 12mm thick perforated particle board/tiles for insulation and accoustic purposes, 60x 60cm in size , fixed with nails to timber frame work or with staples on snap grid ISI Marked , cutting circular holes for electric fittings ,including preparation of surfaces, fillar coat with filler, or liquid filler,transparent,and bringing forward surfaces to smooth even finish and applying three coats of white wash complete all as specified and directed. |
| 11 | S & F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20mm and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre /intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section of 0.55mm thickness having kurled web of 50mm and flange of 26mm each lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete size of grid 605 x 605mm complete all as specified and directed. |
| 12 | S&F for Anodised aluminium snap grid frame work of size 605mm x 605mm for false ceiling, complete all as specified and directed. |
| 13 | M&L 4 mm thick non asbestos fibre cement building boards (size 600X600mm) fixed or laid / inserted to timber / GI / Aluminium frames work with screws as in ceiling flat or sloping incl refixing in position of electric wiring, lights and fittings etc, complete if exists complete all as specified and as directed. |
| 14 | S&F PVC sheet wall lining consisting of 5mm thick colour / printed PVC sheet inclusive of solvent cement and fixing at site including PVC frame as per specifications, complete all as specified and directed. |
| 15 | Supply and fix 5mm thick PVC sheet fillet of width35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification complete all as specified and directed. |
| 16 | Taking down chowaket & shutter exceeding 1.5 Sqm and n exc 4 Sqm removing from site complete all as specified and directed. |
| 17 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site complete all as specified and directed.. |
| 18 | S&F Anodised aluminium powder coated frame for door section/ window section/ ventilator section for side hung type shutter /sliding type shutter/fixed type shutter in two or more tracks, including automatic locking handle , rollers and roller plate & fitting arrangement complete all as all as specified and directed by Engineer-in-charge.(Glass pane , hydraulic door closer , plush plate, floor hinges shall be measured and paid separately. |
| 19 | S & F Anodised(powder coated) aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 20 | S & F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. Please Enable Macros to View BoQ information |
| 21 | S & F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. Please Enable Macros to View BoQ information |