|
| 1 | CONTROL VALVE SERVICING,LP,1.5\\",150KGProviding labour assistance for dismantling, servicing/ overhauling & fixing back of Control Valves of Size - upto 1.5”- Ratings 150/300/600#.Weight range - [50-150kg]Process Flange – 8 stud bolts & 2 hex nuts each/ item. (1/2”~3/4”)Bonnet Flange – 6 stud bolts & 1 hex nuts each/ item.( (1/2”~1”)Actuator Bolt – 12 ~ 20/ item (10mm).Servicing of the control valve shall include disassembling, preparation, surface clearing & cleaning, reassembling of Control Valve Body, Bonnet & Actuator (with new spares supplied by FACT). If required the valve shall be removed from line and fixed back. The control valves shall be assembled/ fixed back in position leak proof as per standard practices / procedures. The work shall be strictly following instructions of OEM’s service technician and FACT’s engineer in charge. All spares, soft parts, fasteners, gaskets shall be supplied by FACT as free issue. |
| 2 | CONTROL VALVE SERVICING,LP,2\\"~4\\",300KGProviding labour assistance for dismantling, servicing/ overhauling & fixing back of Control Valves of Size - 2” to 4”- Ratings 300/600#.Weight range - [150-300kg]Process Flange – 16 stud bolts & 2 hex nuts each/ item. (5/8”~7/8”)Bonnet Flange – 8 stud bolts & 1 hex nuts each/ item.( (3/4”~7/8”)Actuator Bolt – 12 ~ 20/ item (10mm).Servicing of the control valve shall include disassembling, preparation, surface clearing & cleaning, reassembling of Control Valve Body, Bonnet & Actuator (with new spares supplied by FACT). If required the valve shall be removed from line and fixed back. The control valves shall be assembled/ fixed back in position leak proof as per standard practices / procedures. The work shall be strictly following instructions of OEM’s service technician and FACT’s engineer in charge. All spares, soft parts, fasteners, gaskets shall be supplied by FACT as free issue. |
| 3 | CONTROL VALVE SERVICING,LP,10\\"~12\\",1.4TProviding labour assistance for dismantling, servicing/ overhauling & fixing back of Control Valves of Size - 10” to 12”- Ratings 150/300/600#.Weight range - [750-1050kg]Process Flange – 32 stud bolts & 2 hex nuts each/ item. (7/8”~1 1/4”)Bonnet Flange – 12 stud bolts & 1 hex nuts each/ item.( (1 1/4”~1 1/2”)Actuator Dome – 20 ~ 40/ item (10mm).Servicing of the control valve shall include disassembling, preparation, surface clearing & cleaning, reassembling of Control Valve Body, Bonnet & Actuator (with new spares supplied by FACT). The work shall also include to and fro transportation of the control valves to Instrumentation calibration room/ repair bay if required. The control valves shall be fixed back in position leak proof as per standard practices / procedures. The work shall be strictly following instructions of OEM’s service technician and FACT’s engineer in charge. All spares, soft parts, fasteners, gaskets shall be supplied by FACT as free issue. |
| 4 | CONTROL VALVE SERVICING,HP,2\\"~4\\",350KGProviding labour assistance for dismantling, servicing/ overhauling & fixing back of Control Valves of Size - 2” to 4”- Ratings 900/1500/2500#.Weight range - [150-350kg]Process Flange – 16 stud bolts & 2 hex nuts each/ item. (5/8”~7/8”)Bonnet Flange – 8 stud bolts & 1 hex nuts each/ item.( (3/4”~7/8”)Actuator Bolt – 12 ~ 20/ item (10mm).Servicing of the control valve shall include disassembling, preparation, surface clearing & cleaning, reassembling of Control Valve Body, Bonnet & Actuator (with new spares supplied by FACT). If required the valve shall be removed from line and fixed back. The control valves shall be assembled/ fixed back in position leak proof as per standard practices / procedures. The work shall be strictly following instructions of OEM’s service technician and FACT’s engineer in charge. All spares, soft parts, fasteners, gaskets shall be supplied by FACT as free issue. |
| 5 | CONTROL VALVE SERVICING,HP,6\\"~8\\",1050KGProviding labour assistance for dismantling, servicing/ overhauling & fixing back of High Pressure Control Valves of Size - 6” to 8”- Ratings 900/1500/2500#.Weight range - [700-1050kg]Process Flange – 24 stud bolts & 2 hex nuts each/ item. (1 1/8”~1 3/4”)Bonnet Flange – 12 stud bolts & 1 hex nuts each/ item.( (1 1/4”~1 3/4”)Actuator Bolt – 20 ~ 40/ item (10mm).Servicing of the control valve shall include disassembling, preparation, surface clearing & cleaning, reassembling of Control Valve Body, Bonnet & Actuator (with new spares supplied by FACT). If required the valve shall be removed from line and fixed back. The control valves shall be assembled/ fixed back in position leak proof as per standard practices / procedures. The work shall be strictly following instructions of OEM’s service technician and FACT’s engineer in charge. All spares, soft parts, fasteners, gaskets shall be supplied by FACT as free issue. |
| 6 | CONTROL VALVE,TRANSPORTATION,upto 1.5\\",150KGTransportation of control valves of size upto 1.5”, weighing approximately 50–150 kg, to and fro between the site and the Instrumentation Calibration Room / Repair Bay.The scope includes complete transportation for calibration and repair activities. All handling, loading, unloading, and transportation shall be carried out strictly in accordance with the instructions of the OEM’s service technician and FACT’s Engineer-in-Charge, ensuring safety and compliance at all stages. Vehicle if required also shall be arranged by the Contractor |
| 7 | CONTROL VALVE,TRANSPORTATION,2\\"~4\\",350KGTransportation of control valves of size 2” to 4”, weighing approximately 150–350 kg, to and fro between the site and the Instrumentation Calibration Room / Repair Bay.The scope includes complete transportation for calibration and repair activities. All handling, loading, unloading, and transportation shall be carried out strictly in accordance with the instructions of the OEM’s service technician and FACT’s Engineer-in-Charge, ensuring safety and compliance at all stages. Vehicle if required also shall be arranged by the Contractor |
| 8 | CONTROL VALVE,TRANSPORTATION,6\\"~8\\",550KGTransportation of control valves of size 6” to 8”, weighing approximately 300-550kg, to and fro between the site and the Instrumentation Calibration Room / Repair Bay.The scope includes complete transportation for calibration and repair activities. All handling, loading, unloading, and transportation shall be carried out strictly in accordance with the instructions of the OEM’s service technician and FACT’s Engineer-in-Charge, ensuring safety and compliance at all stages. Vehicle if required also shall be arranged by the Contractor Please Enable Macros to View BoQ information |