| 1 | Laying and Jointing PVC Pipe. Heading |
| 2 | SITC out door type double door distribution panel made out of 2 mm thick CRCA sheet of size 800 mm X 600 mm X 300 mm deep having 200 amp 4 nos aluminium bus bar and following acessories mounted thereon. The panel shall be openable from front side and also consists of angle iron frame of size 800 mm X 450 mm with 4 legs of 1000 mm long made out of 50 X 50 X 6 mm thick angle iron. The inside and outside painting should be done with super quality smoke grey synthetic enemelled paint with two or more coats. i) 250 Amp, ATM (Thermal Magnetic) release, 4 pole, 25 KA MCCB, 415 Volt 50 Hz, Adjustable Overload 80-100%, Adjustable short circuit 5-10 In, make of L&T / Havells / Siemens/Crompton/C&S make -01 No. (ii) Volt meter,Amp Meter,Phase indicator etc required at site. |
| 3 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 4 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 5 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 6 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 7 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 8 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 9 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 10 | 11 kV GANG OPERATED SWITCH Supplying, Fitting and Erection of 3-φ 11 kV Gang Operated (G.O.) Air Break Switch 400 Amp having nominal System Voltage of 12 kV, rated Voltage 11 kV, rated Frequency 60 Hz, and peak current in closed position 46 kA, conforming to IS 2544, IS 5340(PartIII) and IS 9921(Part I to V) suitable to opearate in all climatic condition of following current ratings on existing Channels complete with Operating Pipe and Handle including making of necessary Electrical Connections as directed. |
| 11 | Supply & filling fresh transformer oil conforming to ISS 353/1993 including necessary filtering and repairing in buching or per the direction of Engg charge |
| 12 | GST 18% on DSR item No. 2 to 8 (Multipling factor 0.0633) on Rs 52778/- (B) Please Enable Macros to View BoQ information |