| 1 | Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed. |
| 2 | Excavation in trenches/over areas upto 1.5 m deep and getting out in soft/ loose soil complete all as specified and directed. |
| 3 | Excavation in trenches/over areas exc 1.5m and n.exc 3.00 m deep and getting out in soft/ loose soil complete all as specified and directed. |
| 4 | Removing excavated materials (soils) to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.50 above the starting point complete all as specified and directed. |
| 5 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick as in soft/loose soil complete all as specified and directed. |
| 6 | Material & labour for hardcore of broken stone gauges n.exc. 63mm, deposited spread and leveled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 7 | Material & labour for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and sub base of floor complete all as specified and directed. |
| 8 | Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter , complete all as specified and directed. |
| 9 | Use and waste of Form work of sides of pillars, posts, struts, piers, columns etc square or rectangular or polygonal rough surfaces of concrete, complete all as specified and directed. |
| 10 | M&L Form work to sides and soffits of beams lintels etc finished rough , complete all as specified and directed. |
| 11 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick flat fair finished surfaces of concrete. |
| 12 | M&Lfor form work to the edge of concrete flat n. exc 200 mm thick , complete all as specified and directed. |
| 13 | Supply & fix mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 14 | Supply & fix mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required as in stirrups , complete all as specified and directed. |
| 15 | M&L RCC M-25 design mix as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete |
| 16 | M & L RCC M-25 design mix as in Columns, pillars, struts, posts etc complete all as specified & directed. |
| 17 | M & L RCC M-25 design mix as in beams, lintels over 1.5 m span etc , complete all as specified and directed. |
| 18 | M&L for RCC M 25 for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc , complete all as specified and directed. |
| 19 | Material & labour brick work with fly ash bricks in CM 1;6 brick straight or curved on plain exeeding 6m mean radius complete all as specified. |
| 20 | Material & labour for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 21 | Material & labour for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces,in CM(1:4) surface finished even and smooth without using extra cement but using water proofing compound @3% by weight of cement complete all as specified and directed. |
| 22 | Material & labour for 5 mm thick plaster in CM 1:3 on ceiling surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 23 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone agg) 25 mm thick for Sub base flooring , complete all as specified and directed. |
| 24 | M&L cement concrete type D-2 1:4:8 using (40 mm graded crushed stone agg) 100mm thick as in flooring sub base finished even and fair complete all as specified and directed. |
| 25 | M&L machine cut prepolished kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with gray cement slurry mixed with pigment to match the shade of slab including rubbing and polishing upto Granite finish complete over 15mm thick screed bed in CM 1:6 , complete all as specified and directed. |
| 26 | All as per item No 25 above but factory made bull nosed as in riser of steps, skirting/dadolaid over 10mm thick in cm 1:4 , complete all as specified and directed. |
| 27 | M&L 75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in path /plinth protection , finish even & smooth without using extra cement all as specified and directed. |
| 28 | M&L for rendering 15mm thick surface as in roof with integral water proofing compound @3% by weight of cement in CM 1:4 complete all as specified and directed. |
| 29 | M&L for water proofing treatment to roof surface complete all as specified and directed by engr-in-charge laid with following course of description below: a) Apply evenly bituminous based primer conforming to IS 3384-1965 @0.30kg/sqm (b) APP modified bituminous membrane 3mm thick with non woven polyster core of weight not less than 3.2 to 3.5 kg/sqm laid and bonded to the sub strata by heat process, over laps of 100mm both in longitudinal & lateral direction shall be sealed/fused by flamed torch application as per manufacturers instructions. (c) Applying bituminous based aluminium paint @0.20 kgs/sqm in two coats over APP membrane , complete all as specified and directed. |
| 30 | S&F factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ - 0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and including 5mm thick glazing with selected quality glass & required accessories , complete all as specified and directed. (Note: The unit rate quoted by contractor includes cost of glass and includes all other connected accessories. |
| 31 | M& L preparing plastered new surfaces of ceiling and applying three coats of white wash on ceiling surface , complete all as specified and directed. |
| 32 | S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete GDE Fe 410-S , complete all as specified and directed. |
| 33 | M&L Framed work such as grills, angle grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-410-O or Fe-310-O, complete all as specified and directed. |
| 34 | Preparation of new steel surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer , complete all as specified and directed. |
| 35 | S&F 1.00 mm th.mild steel, plain, black sheet in hearths; covering to Manhole cover covering to door chowkats (frames); chullah hoods; water tanks; water troughs: ducts; urinal trought and funnels etc cut to size edges beads, holes punched including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40mm lap joints or welded/ riveted seanes including bending turning up mitred engles, stopped ends, outlets, etc. as required complete all as specified and directed. |
| 36 | M&L three coats of white washing on new plastered surfaces including preparation of surface complete all as specified. |
| 37 | Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint (external weather coat) over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces for painting complete all as specified and directed. |
| 38 | M& L for vitrified parking tiles of size 300mm x 300mm x 10mm thick set jointed and pointed in neat cement slurry in floor and cut and polished with grey cement and pigment incl 20mm thick screed bed in cm 1:4 , complete all as specified and directed. |
| 39 | M&L for moorum/red bajri filing in floors or pavings laid in layers n exc 15cm thick spread levelled and rammed incl watering etc , complete all as specified and directed. |
| 40 | Material and labour for cutting chasing,pinning of brick/ stone/concrete wall at any height wall cutting and chases for concealed wiring for 20/25 mm PVC conduit dia pipe,water tubing,etc and making good to facings where required and pointing in cement motor 1:3 to ends or edges of landigs,wall surfaces etc,cutting not exc 10 cm girth and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directed |
| 41 | M&L for point wiring using approved colour coding incl providing circuit wiring with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conf to IS-694/1990 unsheathed, multistranded, single core, copper cable 1100 volts grade cables drawn through PVC Conduit 20/25 mm dia medium grade(MMS) at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. flush mounting modular MS box made out of 1.60mm thick suitable for modular top cover and frame for fixing of modular switches,sockets,fan regulators, blank plate etc and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with necessary putty for smooth finishing complete all as specified and directed for One light point controlled by one 10amps switch, one way |
| 42 | All as per item no. 41 but for One fan point controlled by one switch 10 amps, and one regulator. |
| 43 | All as per item no. 41 but for One exhaust fan point controlled by one switch 10 amps,one way |
| 44 | All as per item no. 41 but forOne 5 pin 6 amps socket point controlled by one 10 amps switch on independent board . |
| 45 | All as per item no. 41 but for One 5 pin 10 amps socket point controlled by one 10 amps switch on same board . |
| 46 | All as per item no. 41 but for One light point controlled by two 2 way switches. |
| 47 | All as per item no. 41 but for point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for One 6 pin 16/20amps socket outlet point controlled by one 16/20 amps switch on independent board. |
| 48 | All as per item no. 47 but for One 6 pin 16/20 amps socket outlet point controlled by one 16/20 amps switch on same board. |
| 49 | All as per item no. 41 but for point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed. |
| 50 | Supply & fixing modular type switch 10 Amps, single pole,1way,1 module,240V,AC, with ISI Marked complete all as specified and directed. |
| 51 | Supply & fixing modular type switch 10 Amps ,2way,single pole,1 module,240V,AC, with ISI Marked complete all as specified and directed. |
| 52 | Supply & fixing modular type switch 16/20 Amps, single pole,1way,1 module,240V,with ISI Marked complete all as specified and directed. |
| 53 | Supply & fixing modular type socket shuttered type 10 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked complete all as specified and directed. |
| 54 | Supply & fixing modular type socket 16/20 Amps, 6 Pin combined shuttered socket 2 module,240V,AC ISI Marked complete all as specified and directed |
| 55 | Supply & fixing modular type step fan speed regulator 120W, 2 module,230volts,AC, 360 degree rotation 1 to 8 steps, ISI Marked complete all as specified and directed. |
| 56 | Supply & fix red color lighting indication lamp 6 Amps , single pole 240 volts, AC, 50 Hz suitable for 1 ,module ISI marked, complete all as specified and directed. |
| 57 | Supply & fix angle lamp holder latest model, insulated PVC out side body and brass inside holder with back plate for batten fittings/bulbs complete all as specified and directed. |
| 58 | Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed |
| 59 | Supply & fix decorative box type 40 watt light fitting, end caps, pre-wired and including providing single/double side LED tube light (tube rod) white/warm 40 watt-01 No made of aluminium extrusion with high efficient LED driver,IP-20, Tube efficiency of 100lm/w, including PVC/Wooden round/square block -02 Nos and connected with LED fitting to ceiling rose and including removing old unserviceable fitting complete all as specified and directed. |
| 60 | Supply and fixing 20 watts LED Austra ARK mirror smart light fitting one feet long,contemporary design of mirror light complete decorative LED lighting with extruded polycarbonate, environmental friendly, energy efficient, easy to install,PC diffuser, high quality materials,pre-wired including providing PVC round/PVC square blocks-02 Nos and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed. |
| 61 | Supply and fix LED secruity light fitting of capacity 60 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with 4/5 KV inbuilt surge protector and cable connection from ceiling rose/looping box/switch board/DBs to light fitting and testing and including removing of old unserviceable item complete all as specified and directed. |
| 62 | S & F Energy efficient and energy saving new generation 10 watts LED bulk head light fitting IP-65 luminaire with opel diffuser pre-wired of luminaires including LED light driver and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed. |
| 63 | Supply and fix GI bracket pipe of size 32 mm dia medium grade of 1.2 mtr long bent to shape suitable degree of bending as per site requirement with hot or cold bending method of process for making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on wall surfaces and including providing suitable fabricate galvanised flat iron clamps of 30X6 mm thick -02 Nos suitable for fixing at any place/height with hole fastners,nuts,bolts & washers including grouting on wall etc and including removing of old unserviceable item complete all as specified and directed. |
| 64 | Supply & fixing and sheet metal enclosure with acrylic door type, double door ,415 volts AC,VTPN DB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer, and MCB SPN/SP/TPN as outgoing and complete for IP43&54 DBs protection and including removing old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. |
| 65 | Supply & fixing and sheet metal enclosure, with acrylic door type, double door, 240 volts AC,SPN,DB, 8 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoing for IP 43& IP54 DBs protection nd including removing old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed. |
| 66 | Supply & fix and sheet metal enclosure, with acrylic type double door, 240 volts AC,SPN,DB, 4/6 way, flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer,MCB SPN/DP, and MCB SP as outgoing for IP 43& IP54 DBs protection nd including removing old unserviceable DBs making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed. |
| 67 | Supply & fix MCB SP 6 to 32 Amps 10 KA,\\"C\\" series,AC,240Volts,50Hz , ISI marked and including removing old unsv items complete all as specified and directed. |
| 68 | Supply & fix and MCB SPN 32 to 40 Amps 10 KA,\\"C\\" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed. |
| 69 | Supply & fix and MCB TPN 40 63 Amps 10 KA,\\"C\\" series,AC,415Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed as approved by GE |
| 70 | M & L for sub main wiring complete in repairs with 4 run of 10 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit in concealed ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv submain wiring making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Four run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 71 | M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit concealed ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked FRLSH type as earth continuity conductor connected to common earth dolly and including removing old unsv sub main wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 72 | Supply and fix MCCB, 125 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washers and including removing old unserviceable item complete all as specified and as directed. |
| 73 | Supply and fixing ceiling fans complete with blades, down rods, and connected accessories, 230 V, 1200/1400mm sweep, copper winding,antidust -dustproof painted type,high speed,down rod. Star rated with induction motor complete all as specified and directed. |
| 74 | Taking down old unserviceable exhaust fans of any type/sweep from work site and deposit to MES store yard Supply and fix new exhaust fan, steel body AC single phase.230Volts of size 300 mm sweep with blades and including providing insect protection net frame , with louvers and frame incl writing MES No on exhaust fan with synthetic enamel paint complete all as specified and directedcomplete all as specified and directed. |
| 75 | Taking up/down old unsv underground cable from existing locations and supply, laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables 1100 volts grade with stranded aluminium conductor of size 50 sqmm,3.5 core complete all as specified and directed. |
| 76 | Boaring holes horizontally under road without damaging the surface of road (minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of any dia not exc 80mm dia for passing of UG cable all as specified and as directed. |
| 77 | Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. |
| 78 | Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed. |
| 79 | Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed |
| 80 | Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed |
| 81 | M & L for brick sub class 'B' 250mm x 115mm x 0.75mm and laid in trenches as in protection of UG cable complete all as specified and directed. |
| 82 | Material & labour for GI pipe 50 mm \\"light grade\\" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed. |
| 83 | Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC/(PVC hevy duty cover) cover 1:2:4 type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. |
| 84 | Supply and fixing of metal flush box 1/2 module, ISI marked,and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. |
| 85 | Supply and fixing of metal/PVC flush box 3 module ,ISI marked, and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. |
| 86 | Supply and fixing of metal/PVC flush box 4/5 module, ISI marked,and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. |
| 87 | Supply and fixing of metal/PVC flush box 6 module,1.60mm thikness ,ISI marked and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. |
| 88 | Supply and fixing of metal/PVC flush box 8 module,1.60mm thikness ,ISI marked and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed. |
| 89 | Supply and fix modular white cover plate with frame 1 module suitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 90 | Supply and fix modular white cover plate with frame 2 module suitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 91 | Supply and fix modular white cover plate with frame 3 module suitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 92 | Supply and fix modular white cover plate with frame 4 module suitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 93 | Supply and fix modular white cover plate with frame 6 module suitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 94 | Supply and fix modular white cover plate with frame 8 module suitable for GI flush box,ISI marked and suitable for site requirement for above point wiring and incl screws,washears etc complete all as specified and as directed. |
| 95 | Material and labour for 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.ISI Marked IS-15801 lying in trenches/wallc/ceilings or in floors and necessary clamps, saddles etc complete of size outer dia 32-40 mm complete all as specified and directed. |
| 96 | Supply and fixing PPR gate valve(Brass insert) of dia 40 mm fixing at near to building on wall upto one meter height complete all as spfd and directed. |
| 97 | Making connections of PPR pipes distribution branches with PPR main of following sizes of 50 to75 mm by providing and fixing tee including cutting and making fusion joint etc Please Enable Macros to View BoQ information |