| 1 | SupplyofServicetestpanelincludingmeterfortestoftrackequipment,toolsfor mounting and adjustment of track equipment and standard jig for drilling holes in rail. It should be as per Principal manufacturers (OEM)recommended list adequate for installation, day to day maintenance,and adjustment of indoor and outdoor gears. This shall also include kit for making and drillingofholesonrail.DetailSpecificationoftoolskitareprovidedintenderdocument.Inspection: Consignee. |
| 2 | Supply, Installtion & Commissioning of maintenance free earth suitable kit as per RDSO Specificationno.RDSO/SPN/197/2008andDrgNo.SDO/./E&B/001dated:-19.09.2008andDrg No.RDSO/SDO/./E&B/002dated:-19.09.2008.Earthingkitconsistingofearthingelectrodeof17mm dia as 3m long -01 no 2 MEEB (300mmx25mmx6mm) -o1 no. 3. SEEB (150mmx25mmx6mm) -01 no 4. Earthenhancingcompound-30kg(minimum).Thisincludes:-Provisiionofearthconnectionfrom MEEB to S&T equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, IPS, Data Logger etc. with PVC earth wire of size 25/35 sq.mm through copper lugs of suitable size PVC earth wire shall be supplied by contractor. Note: At certain locations, it may not be possible to acheive earth resistance of less than 1.0 ohm with one earth electrode /pit due to soil resistivity. In such cases, provision of loop earth consisting of more than one earth pit shall be done, for interconnection of two earth pits copper tapeofsize25x2sq.mmshallbeprovidedbythecontractor.TheNo\"sofpitsrequiredshallbe decidedbasedontheresistanceachievedfortheearthpitsalreadyinstalled.Theprocedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as seperate earth. Inspection : RDSO for supply portion, Execution- Site Engineer. |
| 3 | Fabrication, supply and fixing of relay racks of size 2200mmx690mm (as per approved Drg.No.NR/S&T/CON/4-3/97A)madeofangleironsize45mmx45mmx6mmalongwithouterframe made of angle iron size 65mmx65mmx8mm, fitted with M.S. squares bars duly galvanised, descriptions strips to accommodate Plug-in-type relays/groups/Point contractor units/ECRs/HMUs. All fixing material like antilting device, hylam sheets if required, bolts & nuts, washers, insulators, shoe, angle irons, flats, L- bolts, Catenary wires and cement concrete etc. will be supplied by the contractor. Thisincludescleaning,primingbyredoxide,painting&descriptionetc.withISImarkpaints. Inspection by Site Engineer. |
| 4 | Fabrication, supply and fixing of cable termination board of size 2200mmx900mm as per Drg. No. NR/S&T/CON/4-1/97A made of angel iron size 40mmx40mmx5mm alongwith outer frame made of angle iron size 65mmx65mmx8mm duly fitted with Bakelite sheet (HYLAM MAKE or similar ) of size 6mm thick. This also includes fixing of ARA terminals/strips/Wago connectors & fuse bases etc. Supply and fixing of hard wood of size 70cmx25cmx4cm in the back at bottom for jamming of armour of cables, each cable in the hole drilled separately for each cable through the salwood plank and all cableentrypointsonlocationboxes,locationhuts,JBsrelayroom/batteryroomtobeclosedwith suitablemasonryWorkscoveredwithsandandplastering.Allthefixingmaterialslikebolts,nuts, washers, Insulators, shoe, angle irons, flats, L- bolts, Catenary wires & cement concretes etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting & description etc. with ISI mark paints. Inspection :Site Engineer |
| 5 | Supply & Installation of Thermo shrink jointing kit for 6-Quad/4-Quad cable for straight throughjointsasperspecifications,drawingsandstipulationsoftenderdocumentsandasper approved cable route plan at various locations. Jointing kits to be supplied as per RDSO specification IRS:TC 77-2012 (Rev.-3) or latest amendments. Inspection : RDSO for supply portion, Execution- Site Engineer. |
| 6 | Supply & Installation of Thermoshrink jointing kit for 6-Quad cable and PIJF cable for Derivation/TerminationjointsatLCGates/PumpHouse/differentlocationsasdecidedbythesite Engineer as per IRS: TC-77/2012 (Rev.3) with amendment 1 & 2 or latest. This includes all materials required for joints. Inspection : RDSO for supply portion, Execution- Site Engineer. |
| 7 | Supply of single app.case steel RE with \"E\" type lock and key ward no.42 and handle as per drg. No. RE/S&T/ALD/SK/219/82 with (Alt A) and 221/82 with Alt.B. Inspection :RITES |
| 8 | Casting, concreting and curing of foundation and erection of single app.cases of size (1160mmx760mm) at surface and 650mm deep as per approved Drg.No.NR/S&T/CON/2-7/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box . All material such as cement,coarse sand,aggregate and anchor bolt shall be supplied by contractor . App.Case single will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection: Site Engineer. |
| 9 | Preparation of App. Case single not involving wiring of relays. Preparation & fixing of bakelitehylumsheet910x800x6mmandBackeliteshelf900x450x10mmdulyfixedbyangleiron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includesfixingoffuses,ARAterminalandfixingandjammingofcableswith2inchthicksalwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in theholedrilledseparatelyforeachcablethroughthesalwoodplankandallcableentrypointson location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of letteringwillbe100mmorasperinstructionsofEngineeratsite.AllmaterialsincludingBackelite shelf,hylumboard,salwoodplank,angleironsquarebar,wireandwiringmaterialaspertheIRS specn., non deteriorating type HRC fuses with bases, catenary wires , nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer. |
| 10 | Supply of apparatus case steel RE half with E type lock and key ward no.42 and handle as per drg.no. RE/S&T/ALD/SK/220/82 and 221/82 with Alt.B. Inspection :RITES |
| 11 | Casting,concretingandcuringoffoundationanderectionofhalfapp.casesofsize (670mmx760mm) and 650mm deep as per Drg.No.NR/S&T/CON/2. 8/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the baseoflocationbox.Allmaterialsuchascement,coarsesand,aggregateandanchorboltshallbe supplied by contractor . App. Case half will be supplied by Railway. Contractor is required to execute alltypeofrepairWorksoffoundationsifrequiredduringinsertingthecablefortermination. Inspection: Site Engineer. |
| 12 | Preparation of App. Case half not involving wiring of relays. Preparation and fixing of Bakelitehylumsheet450x800x6mmandBackeliteshelf450x450x10mmdulyfixedbyangleiron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm.Angleironframewillbefixedinlocationboxsecuredbynutsandbolts.This includes fixing of fuse ARA terminal and fixing and jamming of cable with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specification, non deterioratingtypeHRCfuseswithbases,catenarywires,nutsandboltsandotheritemsshallbe supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer. |
| 13 | Supplyandinstallationofearthelectrodesasperstd.practice.Theitemincludes diggingofpitinearth,3Mtrs.deepandfixingearthelectrodepipe.Castingofcementconcrete enclosures as per drg. No. (NR/S&T/CON/6.4/97). The soil treatement shall be done as per std. pratice. Theitemincludesprovn.ofmildsteelflatofsize35mmx6mm(asperIRSEM)andnutbolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument,cablesheathofpowerequipment,signalbase,apparatuscase,CTrack/relayracks, otherequipmentsaspertheinstructionofEngr.atsite&IRSEM.Earhtingconnectionlocationto location shall be done through cable which shall be provided by Railway. Complete materials such as earthelectrodesasperdrg.No.(NR/S&T/CON/6.3/97),cement,wiringmaterial,nutboltfor connection & mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection : RITES for supply portion, Execution: Site Engineer. |
| 14 | Testing & meggering of all types of outdoor cables after its laying and termination on both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable seperately. This also include dressing and lacing of cable on both ends. Proforma for testing and material for lacing to be supplied by the contractor. Inspection: Site Engineer. |
| 15 | Supply of ARA Terminal Block 25MM center M6 terminal made of PBT as per IRS spec. No.IRS-S-75/2006(Rev.2)&IRSdrawingNo.SA-23741A(Alt.4),SA23745(Alt.5),SA-23746&SA-23756(Alt.3).Inspection :RDSO |
| 16 | Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per approved Drg. No.NR/S&T/CON/1-1/97A. Aso as not to form a drain 0.3 Mtrs. Wide & 1 Mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signallingandcableplan.Italsoincludesclearanceofroootsoftrees&bushes.Inspection:Site Engineer. |
| 17 | ExcavatingandrefillingoftrenchinRockysoiltothelevelofgroundwithrammed earthasperapprovedDrg.No.NR/S&T/CON/1-1/97-A1soasnottoformadrain0.3Mtrs.Wide& 0.5Mtr.Deeponbothsideofthestationalongsidethetrack.Thisincludes50mmthickconcreting workthroughoutin1:3:6ratio.Allconcretingmaterialtobesuppliedbythecontractor.Itshall conform to the safe distance as per signalling and cable plan It also includes clearance of routes of trees & bushes. Inspection: Site Engineer. |
| 18 | Supply and laying of 2nd class bricks in the trench and laying as per approved Drg. No.NR/S&T/CON/1- 1/97A as per instructions of the site Engineer. Inspection: Site Engineer. |
| 19 | Allworkofhorizontalboringandtrenchlesscablingalongwithsupply,transpotation and insertion of double wall corrugated pipe -( ISI marked ) conforming to RDSO Spec no. RDSO/SPN/204/2011, and the laying of cable in the boring under the track / road etc as per instruction of site engg. by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. Inspection : RITES for DWC pipe supply, Execution- Site Engineer. |
| 20 | SupplyandfixingofG.I.pipeperforatedatadistanceof20CMorlessofrequired lengthatculverts/bridges/alongthecuttings,suitablyconcretedatbothendsasperdrg.No. (NR/S&T/CON/1. 4/97) or at ASM office / other buildings suitably fixing it to the wall and at both ends.G.I. clamps of M.S. flats bolts and nut, to be supplied by the contractor. G.I. pipe 75/80 mm dia, 3mm thick. Inspection: RITES for supply portion, Execution- Site Engineer. |
| 21 | Laying of signalling/Telecom/power cables of different sizes as per approved Drg. No. NR/S&T/CON/1-1/97AandaspercablerouteplanapprovedbyRailwaysandmeggeringofcable before and after its laying of all type of outdoor cables. Inspection: Site Engineer. |
| 22 | Supplyofelectricfusecompletewithfuseblock(base)forRailwaysignallingnon- detorioratingtypelowvoltagefuseassembly0.63A2Amp/4Amp/16Amp.tosuit.Specn.No.IRS:S- 78/2006 and fuse block made of PBT/Polycarbonate as per IRS: S-75/2006 (Rev-2 & Amd 2 ) and drg no.23748(IRS)Alt.4orlatest.Fuseblockshallbesuitableforroundheadtypefuses.Inspection:RDSO |
| 23 | SupplyofRelay,ACImmune,plug-intype,Style\"QNA1\",DCNeutralLine,24V contacts,8F-8B,12F-4Bfront&backcontactsmetaltocarbonwithplugboardretainingclipand connectors conforming to BRS 931A,IRS S 60,IRS S34 & IRS S23 (as applicable).Inspection:-RDSO. |
| 24 | Relay, Non AC Immunized, plug in type, style \"\"QN1\"\" DC neutral line 24VDC, 8F/8b , 12F-4B contact, front and back contact metal to carbon with plug board, retaining clip and connect or aconformingtoBRS:930,IRS-S-34-68Adm-6andIRS:S-23/88-Amendment-1(asapplicable).The nterlocking code for this unit shall be ABCDF or latest. Inspection: RDSO |
| 25 | Supply of Portable digital auto range multi-meter clamp type Philips, Motwani, Fluke or Rishabhmakecapabletomeasurefrom(0.1mv/0.01ma)AC/DCupto50Amp(AC/DC),600V(AC/DC) and0.1ohms-40MohmssuitableformeasurementofFreq.,capacitancecompletewithManual, leads, battery and holster etc. Inspection :Consignee |
| 26 | Supply of digital AC/DC low current Clamp meter type Philips, Motwani, Fluke, KOICO or similar. Note: - The technical specification for the concern item is explained in the Annexure-Tech Spec.underChapter-III(i.e.ScopeofTheWorkandTechnicalSpecifications)oftenderDocument. Inspection: Consignee. |
| 27 | SupplyandtestingofelectronicCableRouteLocator/Tracerequipmentofsuitable make capable of tracing electronic markers and different types of underground signalling/ electrical cables /optic fiber cable (OFC) with LCD graphic display Active/Passive modes and depth range 4-10 mtr the set shall consist of the following : (1) Reciever seek tech linelocator/Cable avoindance tool 01 No..(2)Transmitter/SignalGenratorcompletewithearthstakeandconnectionleads.01No.(3) Inductive signal clamp.01 No (4) Carry bag 01 No. Inspection by RITES. |
| 28 | Supply of 200 way/160 way tag blocks conforming to drg no. SA-24751 or latest and as per IRS:S- 77/2006(Rev.1) or latest with latest Corr/Rev./Amdt. Inspection by RDSO. |
| 29 | Fixing,wiring&solderingof160/200waytagblockswithPVCcoveroncable terminationrack/relayrack/blockrack/HVrackasperapprovedDrg.No.NR/S&T/CON/4-3/97A.All fixing material like flats, bolts, nuts, washers etc. will be supplied by the contractor. Inspection: Site Engineer |
| 30 | SupplyofFlexible,PVCsheathed,PVCinsulatedCopperwire16/.20sqmm(wiring materials)asperIRSspec.No.IRS-76/89withamendmentno.3orlatest.(FromRDSOApproved Source only). Inspection :RDSO |
| 31 | Wiring of relays in existing PI/RRI and at LC Gates as per appd wiring diagrams and to suit Railway electrified area. All wiring material including resistances and condensers except cables/wirestobesuppliedbycontractor(Supplyofcables&wirescoveredseparately).Italso includes dressing, bunching, lacing and fixing of relay bases. Inspection: Site Incharge |
| 32 | Fabricating, writing and fixing of description boards made of ply 6mm thick with white sunmicagluedoveritssurfaceand1\"x1\"woodenbattonfittedallaroundontherearandhaving alluminium angle size of 25.4mmx25.4mmx3.15mm on all four sides as per instruction of Engineer at site. All the materials to be supplied by contractor.Inspection :Site Engineer |
| 33 | Supply,installation&wiringofEarthleakagedetector(12Channel)formonitoring different AC and DC, supplies including all accessories as per . specfication no. RDSO/SPN/256/2002 or latest . Inspection: RDSO for supply portion, Execution- Site Engineer. |
| 34 | Supply fixing and wiring of fuse auto changeover system (FACS main system) as per RDSO/SPN/209/2012 Rev. 2.0 with latest amendments. One automatic changeover unit comprise 32 nos of external Non Deteriorating Type or \"G\" type fuses of various Ampere Rating, working voltage- 24 VDC which are in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. .Installation , wiring, Testing and commissioning of Fuse Alarm System,it consists of fixing of modules of fuse alarm system on existing relay rack, wiring from existing fuses to modules, soldering,lacingetc.workingtobeexecutedwithoutaffectingthefunctioningoftheexisting Circuits/Gears and the work shall be supplied by the contractor. Inspection:-RDSO for supply portion, Execution- Site Engineer. |
| 35 | Supply, Installation, Wiring, Testing, Validation and Commissioning of 512 port digital inputand32portanaloginputdataloggerhavinginterfacewithEIwithbuiltinnetworkinternal modemandpowersupplyasperRDSOSpecificationNo.IRS:S-99/2006(Amend-3)orlatest amendmentsorasperlatestspecification.Interfacingandnetworkingofdataloggerwithcentral monitoring shall be done by contractor. This also includes Protocol convertor for dataloggers at main cabin & relay huts. This also includes supply and installation of one Data logger each at Station and Relayhutshaving512Digitalinputsand32AnalogInputsalongwithsupplyofonePCforeach Datalogger with monitor of minimum 32\" size (specs of computer is given in tender document) along withUPS/Inverter&furniturei.e.table&chairforPC,UPSandMonitorofDataloggerandA4laser printer.Inspection:-RDSO for supply portion, Execution- Site Engineer. |
| 36 | Generalconcreteworkincement,coarsesandandaggregateratio1:3:6,work scattered at different places for items not covered in above schedule and fine plastering of top will be done with cement sand ratio of 1:4 . Volume of foundation also includes volume of C.I. base, anchor bolts etc. Coarse sand, aggregate 25mm and cement to be supplied by contractor. Inspection : Site Engineer |
| 37 | SupplyofISImarkedCarbondiOxidetype(BC)fireextinguisherof4.5Kgcapacity confirmingtoIS:2878fromseamlesscylinderconfirmingtoIS:7285withISmarkedcontrolvalue conformingtoIS:3224highpressuremyr.Longdischargehoseandhorncompletewithinitialgas charged with carrying handle and wall mounting braket etc. as required by site Engineer . Inspection: Consignee |
| 38 | Supply of A/AG Marker LED Signal A/AGLighting unit 110V AC. as per RDSO specification no.RDSO / Spen/153/2011 Rev.4.1 with latest amendment / specification. Inspection by RDSO |
| 39 | Supply,Installation,wiring,testingandcommissioningofSignalPostTelephone (SPT)Two-wiretalkbacksystemforABSworkingon110VACconsistingofOneMASTERandOne SLAVE unit MAKE: ACES or similar. Inspection: Supply- RITES, Installation- Site Incharge |
| 40 | PreparationofSWRTranslationofSWRfromEnglishtoHindi.:InspectionbySite Engineer. |
| 41 | Typing and Printing One master Copy SET in Hindi. Inspection: Site Engineer. |
| 42 | Photocopies of Hindi Master Copy Set Inspection: Site Engineer. |
| 43 | SpiralBindingofmasterofSWR&02setofphotocopiesasaboveincludingplastic cover. Inspection: Site Engineer. |