| 1 | M&L for Soakage well of 3M dia X 4.5M effective depth, excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as per CESZ/TD/1078/2011 complete all as specified and directed by Engr-in-charge |
| 2 | S & F PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or floor of 110mm bore pipe complete all as specified and directed by Engr-in-charge |
| 3 | S&F for 110 mm bore PVC (SWR) bends any radius ® complete all as specified and directed by Engr-in-charge |
| 4 | M&L for 100mm thick cement concrete 1:3:6 type C2 bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; complete all as specified and directed by Engr-in-charge |
| 5 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed by Engr-in-charge |
| 6 | M & L Cement concrete 1:4:8 type D2 (40 mm graded crushed stone aggregate ) in foundations, filling and mass concretecomplete all as specified. and directed by Engr-in-Charge. |
| 7 | M&L for Pre-cast cement concrete 1:3:6 type C1 (using 20mm graded agg) block masonry with solid blocks, exc. 10 cm in width and setting in mortar (1:4), complete all as specified and directed by Engr-in-charge |
| 8 | M&L for rendering 15mm thick in CM(1:4) on fair faces of brick work or concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified and directed by Engr-in-charge |
| 9 | M&L for Pre-cast Reinforced cement concrete 1:2:4 type B1 (using 20mm graded agg) as in Manhole cover slab and setting in mortar (1:4), complete all as specified and directed by Engr-in-charge |
| 10 | S & F TMT bars 10 mm dia and above,cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for providingCement concrete 1:2:4 type B-0 (using 12.5mm graded agg)as in Manhole channel complete all as specified and directed by Engr-in-charge |
| 12 | Returning, filling in, including spreading, levelling, wateringand well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-charge |
| 13 | Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-charge |
| 14 | M&L for providingCement concrete 1:2:4 type B-0 (using 12.5mm graded agg) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not providedcomplete all as specified and directed by Engr-in-charge |
| 15 | On site LLDPE septic tank with upflow filter including media designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 25 users complete all as specified and directed by Engr-in-charge |
| 16 | Taking down carefully aluminium/Copper point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with /PVC /MS conduit and T/W battern / casing caping and all as specified and as directed by Engineer-in-Charge. |
| 17 | Taking out old unsv underground cable of any size/make/ type etc from excavted tranches/ on pole passing through pipes etc from different locations complete all as specified and directed by the engr in charge. |
| 18 | M&L for Wiring for circuit/submain wiring alongwith earth wire with the 2x10.0 sq. mm + 1x10.0 sq. mmearth wire of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC Conduit all as specified and directed by Engineer in Charge. |
| 19 | M&Lfor point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Chargefor following :-(a) One light point/one fan point controlled by one switch |
| 20 | M&Lfor point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Chargefor following :-(b) One 3 pin 5 amps socket outlet independent with cables 2.5 sqmm size |
| 21 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Chargefor following :-(c) One 3 pin 5 Amp socket outlet on same boardwith cables 2.5 sqmm size |
| 22 | All same as per item No 20 above but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor Cableall as specified and directed by Engr in Charge. |
| 23 | S&F Socket 2 in 1, 5 pin 5 Amp flush type complete all as specified and directed by Engr In Charge. |
| 24 | S&F Switch piano flush type 5 Amp, single pole, one way complete all as specified and directed by Engr in Charge. |
| 25 | S&fSwitch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed by Engr in Charge . |
| 26 | S&F Switch Socket Combination 2 in 1, 3 pin, 15/16 amp flush type Universal complete all as specified and directed by Engr in Charge . |
| 27 | M&Lfor ceiling rose surface Bakelite 65x50mm two to three terminal complete all as specified and as directed by Engr-in-Charge. |
| 28 | S & FLED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed by Engr in Charge. |
| 29 | S&Fbasic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 10 watt, 2 feet long,with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LHEXACP7IN1W010 or equivalent in Philips/Crompton) |
| 30 | S&F basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 20 watt, 4 feet long,with all accessories complete all as per specified and as directed by Engr-in-Charge.(Havells Cat Pt No. - LHEXAXPNIN1W020 or equivalent in Philips/Crompton) |
| 31 | S&Fin repair sheet metal powder coated versatile Double door SPN distribution board,16 way suitable for MCB\"s fitted with copper bus bar rated 200amps, neutrallink , earth bar and din rail suitable for use on 240 Volt, 50Hz all as directed by Engr in Charge. |
| 32 | M&Lin repair for MCB SPN 63 Amp, 240V with 10KA breaking capacity of \"C\" series in distribution boards all as specified and directed. |
| 33 | M&L in repairto MCB SP 6-32 Amp with 10KA breaking capacity of \"C\" series in distribution boardswith all accessories complete all as per specified and as directed by Engr-in-Charge. |
| 34 | Dismantling and Taking down old u/s street / building sequrity Light fittingsfrom poles, flood lights, post top lantern lights and garden lights forreplacementwith LED fittings all as specified and as directed by Engr in Charge. |
| 35 | Supply and fix LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete Specified and directed by Engr in charge. |
| 36 | M&L for GI bracket 1.5 mtr long made out of GI pipe 40mm dia bend to suitable radius incl clamps nuts bolts washersincl painting with aluminum paint etc complete all as specified and directed by Engr in charge. |
| 37 | M & L in repair for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt,connected to MS galvanized earh stripof size 25 x 4 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, GI strip laid in dia 40 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit (30X30X30cm) with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified. |