| 1 | CIVIL WORK |
| 2 | Dismantling Brick / stone masonry in cement mortar walls and clearing away and carefully stacking materials useful for re-use as directed by the departmental officers. |
| 3 | Earth work excavation for foundation in all classes of soils and sub-soils and to full depth as may be directed except in hard rock requiring blasting including initial leads and lifts and refilling the sides of foundation with excavated earth in 150 mm layers well watered, rammed and consolidated including depositing surplus earth within the godown or inside compound in places shown with initial lead of 10 mts and initial lift of 2 mts. clearing, levelling the site, shoring, strutting, bailing of water wherever necessary etc., complete complying with standard specification and as directed. |
| 4 | CEMENT CONCRETE 1:5:10(one cement, five sand and ten aggregate)using 40mm gauge hard broken granite stone jelly for foundation including de-watering, side shuttering , strutting, wherever necessary including curing etc., complete complying with standard specifications and as directed. |
| 5 | Plain Cement Concrete 1:2:4 ( one cement, two sand, four aggregate) using 40mm gauge hard broken granite stone jelly including dewatering, side shuttering, strutting, wherever necessary including mixing by mechanical means curing etc., complete complying with standard specification and as directed. |
| 6 | Manufacturing, supplying and fixing of stainless steel hand rails for staircase near wet riser using 50mm dia 304L Grade stainless steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade stainless steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grauted into the wall and provided with 93.00mm thick stinless steel circular base plate of 304 Grade. The rate shall included for grouting into corcrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges electrical charges etc., complete. |
| 7 | Providing and laying in position, Standardised Concrete Mix M20 Grade in accordance with IS:456-200 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/M3 and mazimum water cement ratio of 0.55, including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improvement workability without impairing strength and durability with about (5 Cu.m) 7730 Kg of 20mm machine crushed stone jelly and with about (3.3 Cum)5156 kg of 10-12mm machine crushed stone jelly and with about (4.7 Cum) 7670 kg of sand, but excluding cost of reinforcement gril and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, cutting etc., and Providing fixtures like fan clams in the RCC floor/ roof slabs wherever necessary without claiming extra etc., complete complying with standard specification and as directed the departmental officers. The coarse and five aggregates to be used should comply with the requirements of 15 Standards. (No separate payment will be made by the Department for the excess usage of materials.In foundation and basement. |
| 8 | In ground floor upto 4.50M height above basement |
| 9 | Supplying, fabricating and placing in position MS/RTS grills for reinforcement for all R.C.C.works including cost of steel, labour for straightening, bending, cranking, tying grills with 18 gauge galvanized binding wire and placing grills in position complete complying with standard specification and as directed. |
| 10 | Providing FORM WORK for centering the soffits of all reinforcement concrete work including strutting to the required (3 metre) height with mild-steel sheets of size 90cmx60cm 10 gauge stiffened with welded mild steel angles of size 25mmx25mmx3mm laid with country wood joist of average of size 10cmx6.50cm at about 90cm centres with casurina props of 13cm dia at 75cm centre to centre with all nails coir,wedges complete and removing the form work after necessary curing period as directed by the corporations officers. The rates should inclusives of cutting , bending, welding , charges of M.S sheets, M.S. angles etc., CompleteColumn footing, plinth beam, grade beam, Column pedestal etc., |
| 11 | Square RCC column, Rectangular RCC column, RCC boxing etc., |
| 12 | BRICK WORK in cement mortor 1:5(one cement, five sand) using best quality Country bricks of size 8\" 3/4\"x4 ¼ 2 ¾ “ for walls including cost of scaffolding curing, finishing etc., complete complying with standard specification and as directed by the departmental officers.In ground floor upto 4.50M height above basement. |
| 13 | PLASTERING with cement mortor 1:5 (one cement and five sand) 12mm thick including mortar plasticizer at 200ml per 50 kg of cement used , including cost of scaffolding, finishing, curing etc., complete complying with standard specification and as directed. |
| 14 | Painting the walls with two coats of Exterior emulsion paint of first class approved quality and colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed. |
| 15 | Supplying and filling in basement with wetmix 100mm thick in layers of not exceeding 250mm thick, well watered, rammed and consolidated including machineries for hire and running charges leader 5 Cum capacity, hire charges for tipper, water sprinkler,` vibratory roller all labour charges etc., complete complying with standard specification and as directed. |
| 16 | Supplying and laying of Interlocking Paver Block Stone 83mm thick, over a base layer of crushed stone sand filling including cost of materials laying and Labour charges etc., complete as directed by the departmental officers (Paver block stone should be approved by the Executive Engineer before use on work). |
| 17 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade) calcium carbonate and natural fibers (wood powder / rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water /moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-charge. (Note: stainless steel butt hinges and necessary S.S.screws shall be paid separately) 30mm thick. |
| 18 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), Calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position complete as per direction of Engineer-in-charge Frame size 65x100mm. |
| 19 | Stainless steel butt hinges 125x64x2.50mm. |
| 20 | Tower bolt 200x10mm. |
| 21 | Handle 125mm. Please Enable Macros to View BoQ information |