| Sl. No. | Item Description |
| 1 | Demolition of brick work built in cement mortar of any description including all quions arches, pillars, etc complete all as specified and directed. |
| 2 | Taking down cement plaster on brick or stone walls incl wall tiles etc. with raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed |
| 3 | M&L for brickwork with sub class \"B\" bricks (old size), straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed. |
| 4 | M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces complete all as specified and directed |
| 5 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed |
| 6 | M&L for preparation of new plastered surfaces ,applying white cement based wall care putty(Birla/JK white) on the surfaces with minimum1to2mmuniform thickness making surface absolutely smooth by grinding with sand paper and applying two coats of oil emulsion distemper over a coat chalk whiting of approved shade on old surface of wall complete all as specified and directed. |
| 7 | M&L for preparation of new surface andproviding and applying and paintingone coat of super coat acrylic exterior paint of approved make in required shadeover a coat of primer and even finishover acoat of1 to 2 mm thick putty existingon cleaned/primered surface by Mechanical spraying/painting machines)as per manufacturer,s specifacation etc.all complete including all tools,plants scaffolding, safety belts complete all as specified and directed |
| 8 | Dismantling of wall and ceiling boards ( fibre, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness including cover filletscomplete all as specified and directed. |
| 9 | S&F for anodised aluminium snap grid frame work for ceiling complete all as specified and directed. |
| 10 | M&L for 4 mm thick for non -asbestos fibre cement building boards fixed or laid/inserted timber /GI/aluminium frame work with screws complete all as specified and directed. |
| 11 | Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing), removing servicesable tiles to store and rubbish off the premises complete all as specified and directed. |
| 12 | M&L for 25 mm thick plain cement concretetype B0 1:2:4 (12.5mm graded aggregate) as in levelling course of floor and other similar works complete all as specified and directed. |
| 13 | M&L Orient Digital Print Bell Dora forever scratch freefloor tiles 600x600mm (F4 face R2 Slight Variation G5 grouping) square/rectangular in shape matte finish area of tiles exc 0.18 Sqm but not exc 0.36 Sqm, (Joints are filled with glass epoxy admixtures) set and jointed in neat cement slurry and polished in coloured cement to match the shade of tiles over and including 15mm thick screed bed complete all as specified and directed. |
| 14 | M&L for orient Digital Print Bell Dora forever scratch free tiles 600x600mm (F4 face R2 Slight Variation G5 grouping) square/rectangular in shape matte finish area of tiles exc 0.18 Sqm but not exc 0.36 Sqm,(Joints are filled with glass epoxy admixtures) set and jointed in neat cement slurry and polished in coloured cement to match the shade of tiles over and including 10mm thick plaster in skirting complete all as specified and directed. |
| 15 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 16 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 17 | Demolition of cement concrete including floor tiles or stone in any description and any position etc removal from site and complete all as specified and directed |
| 18 | M&L for 75 mm thick cement concrete 1:3:6 type C-2 using 20 mm gradedstone aggregate in plinth protection finished even and fair including necessary form work and cutting of joints using extra cement etc complete all as specified. |
| 19 | Taking down chowkat with shutter (without taking off shutters from the frame) area not exc 1.5 Sqm each and removing from site complete all as specified and directed. |
| 20 | Taking down chowkat with shutter (without taking off shutters from the frame) exc 1.5 Sqm but not exc 4.0 Sqm each and removing from site complete all as specified and directed. |
| 21 | Taking down woodenroof trusses, coupled rafters or trussed beams above 4m & upto 8m clear span complete all as specified and directed. |
| 22 | S&F for MS work as in roof trusses(framed), truses, purlins, crane gantries, rails, and fastenings and heavy bracket framing (beam, tee, angle, channel, or flat section) including distance pieces, cleats etc conforming to Fe-410w Gde 250complete all as specified and directed. |
| 23 | Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and directed. |
| 24 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5mmthick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as complete all as specified and directed. |
| 25 | S&F for pre-painted galvalume aluminum zinc coating GI basedplain steel sheet 0.5mmthick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 26 | M&L in repair for fabrication and fixing of powder coatedaluminium door with frame of section size 85mmx44.50mmx1.56mm thick, shutter with top & bottom rail of section 113mmx44.45mmx1.56mm thick and stiles and middle rails of section 85.5mmx44.45x1.56mm thick with suitable locking arrangement with lock(Make Godrej/link) 6 lever and self closing devices with rebates including jointing cleats of suitable section for fixing builders hard ware fittings , glazing clips rubber packing for air lock purpose, anodised aluminium snap beading screw for fixing glass panel in the same shutter covered with fully selected quality tinted glass 5 mm thick with rubber packing each sutter shall be provided with two Nos decorative type aluminium handle of 200mm long complete all as specified and directed. |
| 27 | M&L in repair for fabrication and fixing of powder coated anodisedwindow & ventilator openable type with frame of section 85mmx44.50mmx1.56mm with shutter style and rail orf powder coated aluminium section of size 47.62mmx44.45mmx1.62mm including joining cleat for fixing builder hardware glazing clips rubber packingfor air lock purpose anodized aluminium strip beading screw etc for fixing glass panes in framesshutter strip beading screw etc for fixing glasspanes in frame shutter covered with fully selected quality glass 4mm thick with rubber packing complete each shutters of window shall be provided with one aluminium tower bolt and one handle of size 150mm, two stainless steel hinges of size 100mm, aluminium stay 01 No, 2 nos 150mm aluminium tower bolt with etc complete all as specified and dircted. |
| 28 | S&F for anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 29 | S&F for Providing and fixing factory made uPVC white colorSliding window Two track made of extruded profiles with wall thickness of 2.3mm (+- 0.2mm). Windowprofile with hollow section with multi chamber, Frame (60mm x 62mm). sash (42mm x 67mm). SlidingInterlock (One vertical length in each shutters) (45.5mm x 28mm). Glazing bead (24.5mmx 16mm)will he mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel frame (30mm x 21.5mm), Sash (30mm x 18mm), profile to be inserted in required profile,frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware : [Touch Lock of zinc alloyed(white powder coated), steel roller system including5mm thick glazing with selected quality glass,aluminum track on bottom rail for two track sliding frame, wool pine for Sliding sash and interlock (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured forpayment purpose)(A) Area not exceeding 2.00 sqm each |
| 30 | S&F in repair 20 mm dia Stainless steel curtain rod of wall thickness not less than 1mm with both side decorative brakets and fixing brakets complete all as specified and specified. |
| 31 | S&F for 4mm thick sheet glass ordinary quality in square n.exc 0.5 Sqm in each pane new door / window shutter complete all as specified and directed. |
| 32 | S&F for MS framed work as in doors frame,doors or gates of angle iron,door frame or other section with gusset plate, rails, braces,grill, hold fast, barrel iron doors, ladders,frame balusters, walk way, railing, frame work of water tank etc complete, drilled for fixing of steel sheeting or other covering etc. to prepared for hanging or sliding with includingeither hooks and hinges, also fastening and fixing and similar work confirming to Fe 290 Gde-E-165 complete all as specified and directed. |
| 33 | S&F for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4mm fixed with screw are galvanised wire staple complete all as specified and directed. |
| 34 | M&L for preparationof old wooden surface of any description not other wise described over 10 cm width or girth and applying two coat synthetic enamal paint overa coat of primer complete all as specified and directed. |
| 35 | M&L for 30mm thick flush shutter,solid core construction with block board core and plywood face panels, commercial type on both sidescomplete all as specified and directed. |
| 36 | S&F for 35 mm thick factory made 2nd class hard wood glazed and skelton shutters, open repeated and prepared to receive glass, gauze etc (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, size of member of shutter as per specified in SSR part-I section 8,clause 8.24(a) and for door and fixed with chowkats,chemically pressure treated complete all as specified and directed. |
| 37 | S&F for 300mm long, aluminium alloy, anodised aldrop door bolt including fixing clips of sheet, cast or exturded section and fixing bolts and 16mm dia bolt of sliding bolts of extruded sections complete all as specified and directed. |
| 38 | S&F for 150mm long anodised aluminium handles, fabricated type complete all as specified and directed. |
| 39 | S&F for 150mm long anodised aluminiumbarrel tower bolt of extruded section complete all as specified and directed. |
| 40 | S&F for 100 mm long mild steel butt hinges, cold rolled, medium weight complete all as specified and directed. |
| 41 | M&L for preparation of newly steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer with paint sprayer machine, complete all as specified and directed. |
| 42 | M&L for Preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer with paint sprayer machine complete all as specified and directed. |
| 43 | M&L for PCC 1:4:8 type D2, using (40 mm graded agg) , 75 mm thick asin sub base of flooring complete all as specified and directed. |
| 44 | M&L forchequered cement concrete coloured tile 30cm X 30cm X25 mm thick with grey cement and pigment set jointed and pointed in neat cement siurry over screed bed or bedding layer 15 mm thick in CM (1:6) in floor all as specified including dismantling of tiles complete all as specified and directed. |
| 45 | Excavation over areas, not exceeding 1.5m deep and getting out in any type of soil complete all as specified and as directed. |
| 46 | Excavation over area, exceeding 1.5m but not exceeding 3m deep and getting out in any type of soil complete all as specified and as directed. |
| 47 | Excavation over areas, exceeding 3m but not exceeding 4.5m deep and getting out in any type of soil complete all as specified and as directed. |
| 48 | M&L for PCC 1:4:8 type D-2, using 40mm graded crushed stone aggregate, as in foundation filing,sub base of floor complete all as specified and as directed. |
| 49 | M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in slabs supported on walls, roof beams etc and the like, complete all as specified and directed. |
| 50 | Use and waste form work to soffits of suspended slabs such as roof slab etc. n.exc. 200mm thick for fair finished surfaces of concrete complete all as specified and directed. |
| 51 | Use and waste formwork to edges of concreteflats, treads, breaks in floors,window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed |
| 52 | S&F for TMT bars of 10mm dia and over in reinforcement cut to length bent to shape required including cranking bending and binding with mild steel annealed wire not less than 0.90 mm dia or securing with clips and as straight in groves complete all as specified and directed. |
| 53 | M&L for brickwork with sub class \"B\" bricks (old size), straight or curved on plan exc 6 m mean radius, built in CM 1:4 complete all as specified and directed. |
| 54 | M&L for Brickwork with sub class‘B’ bricks in one brick thick honey comb walling, builtin CM 1:4 complete all as specified and directed. |
| 55 | M&L for Providing precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 complete all as specified and as directed. (reinforcement to be measured separately) |
| 56 | M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and as directed. |
| 57 | M&L for Loose filling with aggregate of broken bricks of gauge 80 to 150mm in soakage pits, soakage wells, etc complete all as specified and as directed. |
| 58 | Excavation in trenches ,n exc 1.5m wide and n. exc 1.5m in depth, for foundation etc, or for shaft,wells,cesspits,manhole,pier holes,etc n. exc 10 sqm on plan not exc 1.5m depth and getting out in soft /loose soil all as specified and directed |
| 59 | Returning filling in ,including spreading ,levelling,watering and well ramming in layers n exc 25 cm soft/ loose soil complete all as specified and as directed. |
| 60 | Removing excavated soilmaterial n.exc 50m and deposited where directed at a level n exc. 1.5m above the starting point all as specified and directed |
| 61 | M&L for 150 mm dia bore salt glazed stone ware drain pipe grade \"A\" conforming to IS 651-1972 laid in trenches and jointed in CM 1:1 all as specified and directed |
| 62 | M&L for cement concrete bed to drain pipe 150 mm dia including packing underand haunching against the sidesof pipes after they are laid and tested in cement concrete 1:4:8 type D2 using 40mm graded aggregate complete all as specified and directed. |
| 63 | Cutting holes into existing manhole brick wall manhole built in CM, connection new drains making good to pipes and rendering cuttting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished and reforming benching as requiredfor intenal dia of pipe 150mm. |
| 64 | Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. removing materials including accessories for taking credit and making good disturbed surface to match the existing completeall as specified & directed. |
| 65 | M&L for point wiringwith FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) 1100 volts grade concealed in the wall/roof, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium gradeconduit with all fixing accessories of 20 mm dia, and making good to match with the existing surface of wall complete all as specified and directed for the following :- (a) One light/fan/bell point controlled by one switch |
| 66 | M&L for point wiringwith FRLS PVC insulated unsheathed stranded copper conductor cable 2.5 sqmm (nominal area) 1100 volts grade concealed in the wall/roof, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium gradeconduit with all fixing accessories of 20 mm dia, and making good to match with the existing surface of wall complete all as specified and directed for the following :-(a) One point for socket outlet 5 amps on independent board |
| 67 | Description same all as per Item No 66 here in above but for one socket outlet 16 Amp on independent boardwith2.5Sq mmcableand2.5Sq mmearthwire complete all as specified and directed ( power point 15 Amps sockets) |
| 68 | S&F in repair ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed. |
| 69 | S&F for angle/batten type holder insulated body with back plate suitable for light point complete all as specified and directed. |
| 70 | S&F for call bell, ding dong type, AC, 230 V, single polecomplete incl taking out old unserviceable complete all as specified and directed |
| 71 | S&F for modular switch 1 way, 6 amps, 230V AC, one waycomplete all as specified & directed. |
| 72 | S&F for modular socket out let 2-in-1, 3 pin, 6 amp flush type 2 module completeall as specified & directed. |
| 73 | S&F for modular switchflush type 16 amps, 230V AC single pole one waycompleteall as specified & directed. |
| 74 | S&F for modular socket out let 2-in-1, 3 pin, 5 & 16 amp flush type 2 module completeall as specified & directed. |
| 75 | S&F for modular fan regulator, 5 stepped, electronic type, single phase, 120 watt, socket size incl connection completecompleteall as specified & directed. |
| 76 | S&F for Modular metal flush box of 6 module complete all as specified and dircted. |
| 77 | S&F for Modular metal flush box of 4 module complete all as specified and dircted. |
| 78 | S&F for Modular metal flush box of 1/2 module complete all as specified and dircted. |
| 79 | S&F for Modularwhite plate cover with frame of 6 module complete all as specified and dircted. |
| 80 | S&F for Modularwhite plate cover with frame of 4 module complete all as specified and dircted. |
| 81 | S&F for Modularwhite plate cover with frame of 1/2 module complete all as specified and dircted. |
| 82 | S&F for modular bell pushflush type 6 amp, 1 module SP , 230V AC completeall as specified & directed. |
| 83 | Taking downcarefully existing ceilling fan/Exhaust fan and M&L for rifixing the same with nuts,with lock type split pin spring & plate washers etc after painting and oiling greesing as specified and directected. |
| 84 | S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, single pole of current rating 20 amps, C series 240 volts AC completeincluding taking out old unserviceable all as specified & directed. |
| 85 | Supply and fixing in replacement offactory made epoxy polyester powder coated distribution board TP & N 4 way fabricated from recommended thick CRCA sheet with metal double door (IP-43 protection )IK 09 fixed flush to wall and suitable for universal mounting and includingaluminium alloy bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable MCBs as complete all as specified and conforming to IS: 8623 alongwith cable end box for aboveTPN/isolator all as specified and directed. Make : Legrand/GE Power/ Schnieder or equivalent approved by GE)NOTE:- (a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.(c)making good and finishing of disturbed surfaces matching with the exisitng surfaces plastering, wood box work, painting if reqd any type incl ecessary fixing arrangements complete deemed to be included under respective item of sch. (d)Make of MCBs/ MCCBsand MCB DBs shall be same makes. |
| 86 | Supply and fixing in replacement offactory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) and double door IK-09 fabricated from recommended thick CRCA sheet andfixed on wall and suitable for universal mounting and includingaluminium alloy bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 1604 pole MCCBas incommerand 16 to 32 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for aboveDB all as specified. Make : Legrand/GE Power/ Schnieder or equivalent approved by GE) NOTE :- (a) MCBs/MCCB shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.(c)making good and finishing of disturbed surfaces matching with the exisitng surfaces plastering, wood box work, painting if reqd any type incl ecessary fixing arrangements complete deemed to be included under respective item of sch. (d)Make of MCBs/MCCBsand MCB DBs shall be same makes. |
| 87 | S&F for MCB TPN63 Amp,415 Volts, \"B\" series , breaking capacity 10 kA of rating complete all as specified and directed. (for main DB Outgoing) Make- Legrand/ Scheinder/L&T |
| 88 | Supply and fix in replacement ofMCCB 160 Amp 4 pole 25 KA at 415 Vfixed type complete all as specified and directed. |
| 89 | S&F for double door metallic sheet metal enclosure for DB when MCBs to be used SPN8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed. |
| 90 | S&F for MCB single pole, 6 to 32 amps rating, 240 volts, \"C\" series, 10 KA breaking capacity & makingconnection complete all as specified and directed. |
| 91 | S&F for MCB single pole & neutral 40 to 63amp, 240 volts, \"C\" series, 10 KA breaking capacity & makingconnection complete all as specified and directed. |
| 92 | S&F for MCB single pole & neutral 32 amp, 240 volts, \"C\" series, 10 KA breaking capacity & makingconnection complete all as specified and directed. |
| 93 | Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories completeall as specified & directed. |
| 94 | M&L for two single core (submain) FRLS PVC insulated cable and one single core green PVC insulated copper conductor earth continuity cable as mentioned below is drawn in and includingnon metallic, medium duty, rigid PVC conduit not less than 20 /25mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed.Note:- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.(II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM |
| 95 | (a) 2x2.5.0 sq. mm + 1x2.5.0 sq. mm earth wire. |
| 96 | (b ) 2x4.0 sq. mm + 4.0x sq. mm earth wire( for AC Pt ) |
| 97 | (c ) 2x6.0 sq. mm + 6.0x sq. mm earth wire( for AC Pt ) |
| 98 | Taking down existing old /worn out tube/CFL/bulk head/sketch light fittings of indoor type fixed on wall of any type/size with its all accessories including lamp complete all as specified & directed |
| 99 | S&F for LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x18/20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronicDriver ,connector block ect.with all assoceries intenallt prewired &includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable forand mounting clamps complete all as specified and directed |
| 100 | Supply & fixing energy efficient LED light of 10 Watt of length 02 Feet long complete all as specified and directed. |
| 101 | S&F for LED light fitting 10 Watt bulkhead luminaires in high pressure die cast aluminium housing,lumen out put - 700 Lm, colour Temp - 6500 K having Ingress protection - IP 65 fpr dust, water & IK 08 for external impact including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 102 | Supply and fixing building securitylight fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer including taking down old unserviceable complete. |
| 103 | M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washersincluding necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and saltPCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed. |
| 104 | Supply and spreading clean and dry screened sand (unwashed) in trenches around the cable for cushioning all as specified & directed |
| 105 | M&L 50mm bore steel tubing galvanised “Light Grade” in trenches/poles, under floors, roads, along poles for protection of cables, including sealing ends all as specified.Note :- Clamps for fixing pipe on poles shall be included in quoted rate. |
| 106 | M&L 80mm bore steel tubing galvanised “Light Grade” in trenches/poles, under floors, roads, along poles for protection of cables, including sealing ends all as specified.Note :- Clamps for fixing pipe on poles shall be included in quoted rate. |
| 107 | M&L Boring of holes (manually) under road , hard standing without damaging the surface for 50/ 80 mm bore GI Pipe. NOTE:- (i) Depth of hole shall be 1 Metre below the top surface of Road / hard standing. (ii) Pipe shall be measured and paid seperately under respective item of the schedule. |
| 108 | Supply and laying sub class \"B\" brick old sizelaid flat in trenches across the length for protection of cable as cable cover complete all as specified and directed . |
| 109 | Supply & layingcable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs bothe end of cable& wrapping pvc tape over XLPE insulation cable and testing complete all as directed for following size :- (Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid seperately) |
| 110 | (a) 240 Sqmm 3.5 core |
| 111 | (b) 95 Sqmm 3.5 core |
| 112 | (c) 25 Sqmm 4 core |
| 113 | Supply,installation ,testing & commisioning of LT outdoor type pedestal panel of size 1000mm x 1000mm x 150mm, factory made, cubical, double door, powder coated, fabricated with3.15mm thick MS sheet and skeleton with angle iron/ flat iron frame work, front and back openable hinge door with proper locking arrangement , dust and vermin proof, floor mounting type, IP-65 protection including 200Amps rated copper bus bar 3 phase 4 wire system and wiring with suitable copper wiring cable and suitavle PCC foundation completeas per IS and comprising of following:-(a) INCOMING:-(i) MCCB 200 Amps, 35KA ,4Pole 415 Volt, with TMR fixed type - 01 No(ii) Digital Ammeter0 to 500 A with selector switch - 01 No(iii) Digital Voltmeter0-200 V CT ratio type with selector switch and 3 Nos CTs 100/5- 01 No(iv) Phase indicator lamp LED type RYB - 01 Set(b) OUTGOING:-(i) MCCb 125 Amps,25 KA, 4 pole 415 Volt with TMR fixed type -01 Nos(ii)MCCB 63 Amps 25 KA,4Pole 415 Volt with TMR fixed type - 04 No(iii) MCB 40Amps SPN - 03 No Note for item No. (i) Cable gland shall be provided for all incomming and outgoing connections . |
| 114 | Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5metre below the ground level connected to GI strip 32x6 mm by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 40 mm bore medium grade for protection of earth strip, PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways, CI frame and charcoal dust and common salt, all as shown in electrical plate No. 3 of MES SSR part-I and making test point as specified including excavation & earth work in any type of soil and connecting the earthing to an earthing point/equipment as specified and directed& testing on completion.NOTES : (i)The concrete pit shall be made in PCC 1:3:6 type C-1, using 20mm graded crushed stone aggregate 40mm thick precast cover slabof RCC (1:2:4),type B-1,using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover.(ii)Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be adjusted through deviation order(iii) Items includes cost of 7.5 metre earth lead strip. Any variation in length shall be adjusted through deviation order.(iv)Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides |
| 115 | Schedule of Credit (MINUS) Rs. 55,855.00 B/F from Serial Page No.[Note : Detailsof items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail