| Sl. No. | Item Description |
| 1 | Part -1Supplying Installation Testing and Commissioning of 8 MP IP IR Outdoor Bullet Camera having following specifications and features etc :-1) Type of Camera: Outdoor Bullet Camera 2) Image Sensor: 1/2.8\" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC 4)Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better 5)Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6)On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7)Signal to Noise Ratio: > 50 dB8)Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt Smart IR LED\"s with effective distance upto 50 Mtrs integrated IR and 30 meter for colour view in night 9)Video Compression (Minimum): H.265 or better, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 10)Wide Dynamic Range: WDR (120dB or more) 11)Digital Noise Reduction: DNR (2D/3D) On/Off 12)Streaming: Triple streaming, configurable 13)Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 8MP (3840 × 2160)@20 fps, Sub streams: 4MP @25/30 fps & D1@25/30 fps; 14)Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 15)Profile Management: User configuration import, export 16)Security: User Authentication, Digital Water Marking 17)Onboard Storage; Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 18)Recording Management: Format SD, overwrite, storage management, video to NAS device,19)Edge Analytics: Tripwire, Intrusion, Motion Detection 20)Alarm Trigger: Motion/tampering detection;network disconnection detection; IP conflict detection; memory card state detection; memory space detection 21)Alarm Support: It should have 1/1 Alarm In/ Out Port 22)Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression23)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,24)User Access: Minimum 08 Users 25)System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation).26)VMS: Camera shall support open source VMS 27)Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs,account lockout,video encryption, IP/MAC filtering,HTTPS, trusted upgrade. 28)Ethernet: 1 RJ 45 10/100 Ethernet port 29)Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source. 30)Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE 31)Enclosure: IP67 weather proof, IK10 32) Operating Condition: Ambient Temperature:- ()05°C to 50°C, humidity 95% (max) (non-condensing) 33) IR life: 40000 hours or higher 34) Video Bit rate: 32 KBPS - 8 MBPS or better 35) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS8MP (3840 × 2160) or better IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor BulletCamera. |
| 2 | Supplying Installation Testing and Commissioning of PTZ (Pan,Tilt and Zoom)IP IR Camera having following spcifications and features etc :-PTZ (Pan,Tilt and Zoom)IP IR Camera having following spcifications and features etc :-1) IP IR PTZ Camera: Motorized PAN TILT ZOOM with IR 2) Image Sensor: 1/2.8\" or better progressive Scan CMOS 3)Signal System: PAL/NTSC 4) Minimum Illumination: 0.008 Lux@ F1.6, AGC ON,, 0 lux with IR,or better 5) Imaging: 1/1s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Image Rotation,Multi zone Privacy Masking (Upto 24 Area), HLC, Defog, Region Of Interest and EIS features. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB8) Event Notification: Through Relays, E-Mails or FTP 9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED\"s witheffective distance. The camera should have IR LED’s and cover distance up to 300 meter or above 10) Auto Tracking: The camera should be equipped with Deep-learning-based auto tracking function using simultaneously all of the panning, tilting and zooming should be available. When a motion is detected in a registered monitoring area, the camera should track the motion (object) and capture it. 11) Pre/Post Event Buffering: The camera should support atleast of 5 seconds of pre & post event buffering. 12) Presets: 300 Presets 13) Video Compression (Minimum): H.265 or better, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 14) Wide Dynamic Range: WDR (120dB or more), HLC & BLC 15) Digital Noise Reduction: DNR (2D+3D) On/Off 16) Image Setting: Rotate Mode, ROI ,EIS, Defog, saturation, brightness, contrast, sharpness adjustable through client software or web browser 17) Profile Management: User configuration import, export18) Cyber Security: Configuration encryption, AES 256-bit Encryption, Digest, account lockout, video encryption, IP/MAC filtering, trusted boot, trusted upgrade, trusted execution 19) Onboard Storage: Camera should support built in Micro SD/SDHC/SDXC Card slot upto 512 GB . It should be supplied with minimum 128GB Memory. 20) Recording Management: Format SD, overwrite, storage management, video to NAS device, remote archive access via FTP login 21)Edge based Video Analytics & Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection, Tripwire, Intrusion, Object Abandon/ Missing, SMD, Face Detection 22) Network Protocol: SFTP, IPv6, IPv4, DNS,NTP,HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS,ICMP,DHCP, SMTP, RTSPS. 23) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation). 24) VMS: Camera shall support open source VMS 25) Connectivity: 1x LAN RJ-45 (10/100Base-T) 26) Audio Support: Audio Interface : The camera should have1/1 Audio In/Out to connect External Mic and Speaker Audio Compression : PCM, G.711U/A, G.711MU, G.726, MPEG2-Layer2, G.722.1 27) Alarm In/Out : Alarm In/out- 7/2 Ch In/Out 28) Power Input: The camera should support simultaneous dual power input—DC/ AC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 29) Power Requirement: 24 VDC, 2.5 A (± 25%), PoE+ (802.3at) 30) Enclosure & Weather Proof Standard: IP67 weather proof and IK10, TVS 8000V lightning proof, surge protection, voltage transient protection 31) Operating Condition:- Ambient Temperature:- ()05°C to 50°C, humidity 95% (max) (non-condensing) 32) IR life: 40000 hours or higher 33) Video Bit rate: 32 KBPS - 8 MBPS or better 34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 2 MP IP IR motorized PTZ@ 25/30fps or better camera, Triple streaming , configurable on resolution Main stream:1080p@25/30 fps Sub streams :1080p@25/30 fps & D1@25/30 fps or better,varifocal lens 4.3-137 mm or better with Automatic & manual Focus Adjustment provisions, 32x Optical zoom and 12x Digital zoom with angle of view 57˚–2.4˚ , PAN Travel: Pan: 0° ~ 360° endless,Manual Pan: 260° /s, Preset : 300° /s, Tilt,Travel: Tilt: -20° ~ 90°, auto flip 180°, Manual Tilt: 120° /s, Preset : 200°/s. |
| 3 | Supply, installation, testing & commissioning of 4MP IP ANPR Camera:• 1/1.8\"\" 4 MP CMOS sensor • Max. 4MP (2688 × 1520)@30fps• H.265, H.264M, H.264H, H.264B, MJPEG• 10 mm–40 mm Motorized Lens• ANPR capability should be available • WDR(120dB) or better, Day/Night(ICR), 3D NR, BLC, HLC• IR Range of 20 Mtr. or better , IP67, IK10• Alarm Inputs / outputs: 1 input & 1 output or more should be available • Audio Inputs / outputs: 1 input & 1 output should be available• ANPR Feature: Recognize license plate numbers and letters , Vehicle head: Large bus, heavy truck, medium truck, sedan, van, light truck, medium bus, SUV, large bus, Vehicle Color, Vehicle Logo• Traffic Flow Detection: Statistics on vehicle flow, average speed, vehicle type, lane occupancy, average time headway, average queue length, and road status.• ONVIF Profile ‘S’ ‘T’ & ‘G’• CE,FCC,ROHS,ONVIF,BIS and Cyber security certificate from STQC:- OWASP application verification standard v4.0- Appendix C: Internet of Things verification requirement L2. • CCTV OEM should have ISO9001:2015, ISO 14001:2015, ISO 27001:2013 , ISO 45001:2018 & GDPR Certificate. |
| 4 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR)with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth. 2) NVR should support video compressions : H.265 or better, H.264, MJPEG. 3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions. 4) Intelligent auto power on when power resumes after power outage. 5) Storage:It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10. 6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232,1x eSATA Port 7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0) 8) Video Output Ports:2x HDMI and 2 VGA 9) Alarm Ports:It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options:Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic 11) Web & Mobile Application:Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols:HTTP, HTTPS, TCP/IP, IPv4/IPv6,UDP, DHCP, DNS, SMTP, UPnP, IP Filter,PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards:CE, FCC, RoHS, BIS Certified 14) Power Supply : Should support AC100-240V, 50/60 Hz Power supply. 15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing) 16) The VMS application shall support all the features & functionalities of the offered cameras. 17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality. 18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet. 20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode 21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF 22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page 23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm24) It should have Web and GUI interface. 25) Built-In Artificial Intelligence:NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection 26) Face Recognition Database Capacity:It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image. 27) Face & Human Attributes Search:Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. 28) ANPR Capability:It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. 29) Alarm Notifications based on:Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan,cybersecurity exception30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.31) General AI Based Search:Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 32) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency 33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics34) Analytics by NVR: Perimeter protection and face recognation64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/36/64, 2nd screen: 1/4/8/9/16 |
| 5 | Supplying, Installation, Testing and Commissioning following capacityServeillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 1(0TB (Terabytes) |
| 6 | Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system),Key Board, Optical Mouse, etc. as required. 55 inch or larger |
| 7 | Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring.The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly followingStandards: ISO 11801,IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core,High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath,Operatingambient Temperature should be– 5 0C to +50 0C and Storage Temperature shall be– 5 0C to +50 0C, Max Attenuation ± 0.36 (db/ km) at Operational Wavelength1310 nm and± 0.22 db / km at Operational Wavelength1550 nm. type of fibershould be 9/125 / G.652D& Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter9.2 ± 0.4 µm and 125 ± 0.7 µm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required.. Single Mode 6 Core Optical fiber cable |
| 8 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted PairCable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5 Kg etc. complete as required. 1 Run of cable |
| 9 | Supplying of 3Cx2.5 Sq.mm 1.1 KV grade annealed copper conductor armoured Cable having XLPE insulation, steel wire armouring & FRLS PVC sheath etc. conforming to IS:7098 (part-1)Complete as required. |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required. Upto 35 sq. mm |
| 11 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.(A) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 12 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (A) 25 mm |
| 13 | Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table.Internal dual AC Power supply with operating temperature of -5 degree Celsius to +50 degree Celsius. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDPMED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India.8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+. |
| 14 | Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required. 1 G SFP Single Mode/Multi Mode. |
| 15 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under:At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table.Console Port, USB port, Stackingsupport of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India. 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each cooper port supporting 802.3at PoE+ min. |
| 16 | Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Preassembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. |
| 17 | 6 Port LIU |
| 18 | 24 Port LIU |
| 19 | Supplyin,erection,testing and commissioning of 6 Metre Galvanized Iron Pole of 50 mm dia B-Class conforming to IS:1239 Part-I(2004), duly welded with MS base plate of size 200 mmx200 mmx12 mm thick with necessary accessories i/c painting, numbring, etc. complete as required. |
| 20 | Supplying and laying in position of1:2:4 ( 1 cement: 2 Coarse sand : 4 graded stone aggregate)RCC foundation of size 500 mm (L) x 500 mm (W) x 1600 mm (D) i/cexcavation of earth, re-filling, providing,cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 1760 mm long (approx)- 8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia - 2000 mm long (approx)-12 Nos. on 150 mm spacing supply and fixing of one set comprizing of 4 Nos. 20 mm dia 700 mm long J type foundation bolts(threaded portion shall be galvanized) along with 3 Nos. GI nuts and 2 Nos. GI washer per bolt, 2 Nos. DWC pipe of 63 mm. dia. of suitable length embeded in the foundation for drawing of incoming & outgoing cable after excavation for foundation , dressing of sides and ramming of bottoms, lift upto 1.5 mtr and getting out the excavated soil and disposal of surplus excavated soil as directed by Engineer-in Charge etc. complete as required.. The Tor steel used in Foundations shall be ISI marked. |
| 21 | Supply and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corningsinglemode G652D, Cable Type 2mm withMechanical specification Apex Offset< 50 µm,Fiber Height +100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 deg C to +50 deg C, Storage Temperature – 10 deg C to +50 deg C, Length -- 2 meter, Type -- LC-LC Duplex etc complete as required. |
| 22 | Supply and fixing 24U Rack with 4 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.25mm CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with \"U\"Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 5nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 23 | Supply and fixing Outdoor Pole/ Wall mount6U Rack, IP55, Front Door with Filter, Louver & Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesive thermal foam from inside. Hood For Air Inlet at front side.1U Cantilever Tray 250 mm Depth, Gasket. etc complete as required. |
| 24 | Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load(Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shallinclude a Rectifier, inverter, battery bank suitable for 30 minutes back up(Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container)and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall beMicroprocessor based Digital Control,using Insulated Gate Bipolar Transistor (IGBT)\"s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturingand inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE.The operating efficiency of the UPS systems shall be >95% at 100%non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input gridshall be< 5% at 100 %load. (The required LCfilters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall besuitable for incoming supplyAC single phase 160-270V 50 Hzand delivering output ACsupply true sine wavesingle phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Displayfor watt/VA,Amp and Voltage power parametersetc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2,it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be withIGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductorcable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPSshould have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. 10 KVA |
| 25 | Earthing Earthing with G.I. Earth Pipe 4.5 mtr long, 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 26 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for conneciton etc. as required. |
| 27 | Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia GI pipe from earth electrode including connection with GI nut bolt , spring washer, excavation, refilling etc. as required. |
| 28 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existingsurface /recessedconduit submain wiring /cable as required. |
| 29 | Part -II Comprehensive Maintenance i/c breakdown maintenance of Complete installation as provided in Part-I for first year after completion of defect liability period as per terms and conditions attached complete etc as required. |
| 30 | Comprehensive Maintenance i/c breakdown maintenance of Complete installation as provided in Part-I for 2nd year after completion of defect liability period as per terms and conditions attached complete etc as required. |