| 1 | Repairing Of Existing Gowdown Unit 01 |
| 2 | Dismantling brick masonery in lime or cement mortar and stacking the materials as directed with all leads and lifts etc. |
| 3 | Providing second class Burnt Brick Masonery with conventional I.S. type bricks in cement mortar 1:6 in superstructure including striking joints , racking out joints , watering and scaffolding etc complete. |
| 4 | Providing and fixing Rolling Shutter fabricated from steel laths of min. thk. 0.9 mm with lock plate of 3.15 mm thk. Reingorced with 35*35*5 mm angle section fitted with sliding bolts and handles for boh sides , deep M.S. Channel section of depth and thk. not less than 65 mm and 3.15 mm respectively with holdfast arrangement .M.S.Bracket plate 300*300*3.15 mm min.size and shape with square bar , suspention shaft of min. 32 mm diamter, hood cover of M.S. Sheet not less than 0.9 mm thk. and of any size at top and safety devices including Machnical Gear operation arrangement consisting of worm gear wheels and worms of high grade Cast Iron or M.S. and one coat of primer etc complete (I.S.62481979)( With Mechanical Gear) |
| 5 | Providing and Fixing only gear operation arrangement to old rolling shutters as directed by the Engineer In Charge |
| 6 | Providing and Fixing 6 mm thick M.S. bottom rail with 10 mm thick M.S. Flat locking patti arrangement to old Rolling Shutters as directed by the Engineer In Charge |
| 7 | Providing and Fixing Central Lock to OLD & NEW Rolling Shutters as directed by the Engineer In Charge |
| 8 | Providing oiling and greasing , giving tension to springs and total overhauling to OLD Rolling Shutters complete as directed by the Engineer In Charge |
| 9 | Providing and fixing in required position skirting or Dado of POLISHED KOTAH STONE Slab , 25-30 mm thick on base of plaster or cement mortar 1:4 including cement float, filling joints wth neat cement slurry curing, polishing and cleaning etc complete. |
| 10 | Removing old G.I. SHEETS from roof with all safety and stacking neatly within a lead of 50 M. and all lifts complete as directed by Engineer in Chief. |
| 11 | Providing and fixing colour coated ZINCALUME (R) (MM 150 Gms per SQ.M.total on each side )profiled shteetsfor roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness (RMT 110.50 mm TCT) High Strength Steel with min 550MPa yeild stregth material hot dip coated with Aluminium -Zink alloy (55%Aluminium ,43.4% Zink , 1.6%Silicon ) with COLOURBOND (R) Steel quality super durable polyester paint coat( with inorganic pigment ). The paint should have a total coating thickness of nominal 35 um, comprising nominal 25 um exterior coat on top surface and nominal 10 mm reserve coat on back surface. Profile sheet shall have nom 950-1050 effective cover width and nominal 25-30 mm rib with subtle square fluting in the five pan at nominal 180-250 mm center to center. The end rib shall be designed for anti-capilary grooves and return leg. The feed material should have coil manufacturers product details marked a regular interval . Including fasteners with min. fastened with min.25 um Zink-Tin alloy coated. Hex head self drilling screw ec. complete ( weight of profile 4.32Kg (one square meter). |
| 12 | Same as above Item no. 10 for Ridge capping |
| 13 | Providing and applying two coats Synthetic Enamel paint of approved colour to new/old Structural Steel work and Woodwork in building including scantllings if necessary cleaning and preparing the surface(excuding primer coat) etc. complete.(OLD TRUSS) |
| 14 | Providing and applying two coats Synthetic Enamel paint of approved colour to new/old Structural Steel work and Woodwork in building including scantllings if necessary cleaning and preparing the surface(excuding primer coat) etc. complete. (ROLLING SHUTTERS) |
| 15 | Providing and Appliying White-wash in two coats on OLD/NEW plastered or masonery surfaces and Asbestos Cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. |
| 16 | Providing and Appliying Colour-wash of approved colour and tinge in two coats on OLD surfaces which are to be recoloured including scaffolding and preparing the surface by brushing and brooming down (excluding base coat)etc. complete. |
| 17 | Providing second class Burnt Brick Masonery with conventional I.S. type bricks in cement mortar 1:6 in superstructure for Parapet Wall including striking joints , racking out joints , watering and scaffolding etc complete. |
| 18 | Providing sand faced cement plaster externaly in cement mortar using approved screened sand in all positions including basic coat of 15 mm thick in C.M. 1:4 using waterproofing compound at 1Kg./Cement Bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6-8 mm thick in cement mortar 1:4 finishing the surface to taking out grains and curing for 14 days scaffolding etc. complete. |
| 19 | Providing Internal cement plaster 12 mm thick in single coat to internal surfaces without neeru finish to concrete or brick surfacesin all positions including scaffolding , curing etc. complete. |
| 20 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 M. or sprading in the compound and cleaning the site etc. complete. |
| 21 | Providing and laying Chequred Tiles of approved quality of size 30 cm*30 cm. conforming to corrosponding I.S.Codes for Flooring in required position laid to required position laid on a bed of 1:4 C.M. including cement float , flling joints with cement slurry , cleaning , curing etc. complete. |
| 22 | Providing Patti/ Band 100 mm wide on APRON SIDES plastered surface 12 mm to 15 mm thick in C.M. 1:3 , Line and level including neat finishing , scaffolding , curing etc. complete. |
| 23 | Providing and applying two coats Waterproof cement paint of approved manufacturer and of approved colour to new plastered surface including scaffolding , if necessary cleaning and preparing the surface(excuding primer coat) etc. complete. |
| 24 | Removing M.S. Kerb channel, Providing ,Fabricating holdfast by proper welding and Refixing M.S.Channel in position by cement cocrete 1:2:4 grade complete as directed by Engineer-In- Chief. |
| 25 | Providing flush grooved pointing with cement plaster 1:3 for Stone masonery work including scaffolding and curing etc. complete. |
| 26 | Removing Cement Tiles, or Mable, or Polished Shahabad floor or dado without bed concrete including stacking the materials as directed with all leads and lifts etc. complete. |
| 27 | Providing and laying Polished Shahabad Stone Flooring 25 to 30 mm thick and required width wide in plane/ diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry , curing , polishing and cleaning etc. complete. |
| 28 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50 M. beyond the building area and stacking , spreading as directed, dewatering, preparing the bed for foundation, and necessary backfilling, ramming, watering including shoring and struting, etc.complete. (Lift upto 1.50 M.)By manual means |
| 29 | Providing dry /trap/ granite/ Quartzite/Gneiss rubble stone Soling 15 to 20 cm thick including hand packing and compacting etc. complete. |
| 30 | Providing and Laying cast in situ / Ready Mix Concrete in M-10 of Trap/Granite/Quartzite/ Gneiss Metal for foundation and bedding including bailing out water, Steel centring, formwork,laying/pumping, compacting, roughening them,if special finish to be provided, finishing if required and curing complete with fully automatic microw processor based PLC with SCADA enabled reversible Drum Type mixer/ Concrete Batch Mix Plant ( Pan Mixer) etc. complete. With fine aggregate(Crushed Sand VSI Grade). |
| 31 | Providing Second Class Burnt Brick masonry with convenional/ I.S. type bricks in C.M.1:6 in foundation and plinth of inner walls in plinth of external walls including bailing out water manually, sticking joints on unexposed faces, racking out joints on exposed faces and watering etc. complete. |
| 32 | Providing and Laying Antiskid Ceramic tiles of approved quality of size 30 cm*30cm and confirming to I.S.15622-2006(GROUP-B HA) for antiskid flooring of Trads and Risers in required position laid on a bed of 1:4 C.M.including cement float , filling joints with cement slurry cleaning, curing etc. complete. |
| 33 | Providing and Fabricating structural steel work in rolled sections, fixed with connecting plates or angle cleats in main and cross beams, hip and jack rafters, purlins connecting to truss members and the like , as per detailed design ad drawings or as directed including cutting, fabricating hoisting, erecting, fixing in position , making revated/ bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete -- Ladder |
| 34 | Royalty |
| 35 | Murum and other minerals |
| 36 | Material Test |
| 37 | Bricks - Water Absorption, Comp. Strength, Efflorescence |
| 38 | Sub Estimate No .2 :- Electrical |
| 39 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 40 | Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR |
| 41 | Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 42 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 10A, 2 pin plug & earth socket and 10A, 3 pin plug top with 10A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. |
| 43 | Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW |
| 44 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base. |
| 45 | Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG- ODF/FLS2. |
| 46 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 47 | Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 48 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 49 | Repairing Of Existing Gowdown Unit 02 |
| 50 | Dismantling brick masonery in lime or cement mortar and stacking the materials as directed with all leads and lifts etc. |
| 51 | Providing second class Burnt Brick Masonery with conventional I.S. type bricks in cement mortar 1:6 in superstructure including striking joints , racking out joints , watering and scaffolding etc complete. |
| 52 | Providing and fixing Rolling Shutter fabricated from steel laths of min. thk. 0.9 mm with lock plate of 3.15 mm thk. Reingorced with 35*35*5 mm angle section fitted with sliding bolts and handles for boh sides , deep M.S. Channel section of depth and thk. not less than 65 mm and 3.15 mm respectively with holdfast arrangement .M.S.Bracket plate 300*300*3.15 mm min.size and shape with square bar , suspention shaft of min. 32 mm diamter, hood cover of M.S. Sheet not less than 0.9 mm thk. and of any size at top and safety devices including Machnical Gear operation arrangement consisting of worm gear wheels and worms of high grade Cast Iron or M.S. and one coat of primer etc complete (I.S.62481979)( With Mechanical Gear) |
| 53 | Providing and Fixing only gear operation arrangement to old rolling shutters as directed by the Engineer In Charge |
| 54 | Providing and Fixing 6 mm thick M.S. bottom rail with 10 mm thick M.S. Flat locking patti arrangement to old Rolling Shuttersas directed by the Engineer In Charge |
| 55 | Providing and Fixing Central Lock to OLD & NEW Rolling Shutters as directed by the Engineer In Charge |
| 56 | Providing oiling and greasing , giving tension to springs and total overhauling to OLD Rolling Shutters complete as directed by the Engineer In Charge |
| 57 | Providing and fixing in required position skirting or Dado of POLISHED KOTAH STONE Slab , 25-30 mm thick on base of plaster or cement mortar 1:4 including cement float, filling joints wth neat cement slurry curing, polishing and cleaning etc complete. |
| 58 | Removing old A.C SHEETS from roof with all safety and stacking neatly within a lead of 50 M. and all lifts complete and as directed by Engineer in Chief. |
| 59 | Providing and fixing 6.00 mm thk. ISI mark Asbestos Cement Corrugated Sheet roofing including galvanised iron \"J\" or \"L\" Hookbolts, G.I. band bituminous ,G.I Washers, G.I. clamps, bols, nuts and scaffolding etc. complete. |
| 60 | Providing and fixing 6.00 mm thk. ISI mark Asbestos Cement Corrugated Ridge Capping for roofing including galvanised iron \"J\" or \"L\" Hookbolts, G.I. band bituminous ,G.I Washers, G.I. clamps, bols, nuts and scaffolding etc. complete. |
| 61 | Providing and applying two coats Synthetic Enamel paint of approved colour to new/old Structural Steel work and Woodwork in building including scantllings if necessary cleaning and preparing the surface(excuding primer coat) etc. complete.(OLD TRUSS) |
| 62 | Providing and applying two coats Synthetic Enamel paint of approved colour to new/old Structural Steel work and Woodwork in building including scantllings if necessary cleaning and preparing the surface(excuding primer coat) etc. complete. (ROLLING SHUTTERS) |
| 63 | Providing and Appliying White-wash in two coats on OLD/NEW plastered or masonery surfaces and Asbestos Cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. |
| 64 | Providing and Appliying Colour-wash of approvedccolour and tinge in two coats on OLD surfaces which are to be recoloured including scaffolding and preparing the surface by brushing and brooming down (excluding base coat)etc. complete. |
| 65 | Providing second class Burnt Brick Masonery with conventional I.S. type bricksin size 35cm*35 cm for Parapet Wall in cement mortar 1:6 in superstructure for Parapet Wall including striking joints , racking out joints , watering and scaffolding etc complete. |
| 66 | Providing sand faced cement plaster externaly in cement mortar using approved screened sand in all positions including basic coat of 15 mm thick in C.M. 1:4 using waterproofing compound at 1Kg./Cement Bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6-8 mm thick in cement mortar 1:4 finishing the surface to taking out grains and curing for 14 days scaffolding etc. complete. |
| 67 | Proving Internal Cement plaster 12 mm thick in single coat in C.M. 1:5 without Neerufinish to concrete or brick surfaces in all position including scaffolding and curing etc. complete. |
| 68 | Dismantling the R.C.C. Work and sorting out the materials such as steel etc as directed and stacking them within the specified lead as directed etc. complete. |
| 69 | Providing and laying in situ cement concrete M-20 G with TRIMIX Treatment with Vacuume Dewatering for 100 mm thickness for flooring with groove cutting of 4 mm wide and 20 mm deep with necessary refilling with bitumen etc. complete as directed by Engineer In Charge with all leads and lifts complete. |
| 70 | Removing M.S. Kerb channel, Providing ,Fabricating holdfast by proper welding and Refixing M.S.Channel in position by cement cocrete 1:2:4 grade complete as directed by Engineer-In- Chief. |
| 71 | Providing Patti/ Band 100 mm wide on APRON SIDES plastered surface 12 mm to 15 mm thick in C.M. 1:3 , Line and level including neat finishing , scaffolding , curing etc. complete. |
| 72 | Proving and fixing 24 OZ thick glass panes to windows as diected by Engineer- In- Charge, complete. |
| 73 | Providing and fabricating structural steel work in rolled sections, fixed with connecting plates or angle cleats in main and cross beams, hip and jack rafters, purlins connecting to truss members and the like , as per detailed design ad drawings for 400 mm wide and 9.00 m high M.S. Ladder, providing holdfast by proper welding and fixing in position by cement concrete 1:2:4 foundation bed block , etc. complete as directed by Engineer-In Charge. |
| 74 | Providing flush grooved pointing with cement plaster 1:3 for Stone masonery work including scaffolding and curing etc. complete. |
| 75 | Removing Cement Tiles, or Mable, or Polished Shahabad floor or dado without bed concrete including stacking the materials as directed with all leads and lifts etc. complete. |
| 76 | Providing and laying Polished Shahabad Stone Flooring 25 to 30 mm thick and required width wide in plane/ diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry , curing , polishing and cleaning etc. complete. |
| 77 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50 M. beyond the building area and stacking , spreading as directed, dewatering, preparing the bed for foundation, and necessary backfilling, ramming, watering including shoring and struting, etc.complete. (Lift upto 1.50 M.)By manual means |
| 78 | Providing dry /trap/ granite/ Quartzite/Gneiss rubble stone Soling 15 to 20 cm thick including hand packing and compacting etc. complete. |
| 79 | Providing and Laying cast in situ / Ready Mix Concrete in M-10 of Trap/Granite/Quartzite/ Gneiss Metal for foundation and bedding including bailing out water, Steel centring, formwork,laying/pumping, compacting, roughening them,if special finish to be provided, finishing if required and curing complete with fully automatic microw processor based PLC with SCADA enabled reversible Drum Type mixer/ Concrete Batch Mix Plant ( Pan Mixer) etc. complete. With fine aggregate(Crushed Sand VSI Grade). |
| 80 | Providing Second Class Burnt Brick masonry with convenional/ I.S. type bricks in C.M.1:6 in foundation and plinth of inner walls in plinth of external walls including bailing out water manually, sticking joints on unexposed faces, racking out joints on exposed faces and watering etc. complete. |
| 81 | Providing and fixing in position 11.35 M. high Lightening Arrester as per drawing ,design, specification etc. complete as directed by Engineer -In -Charge. |
| 82 | Providing and applying two coats of Waterproof cement paint ofapproved manufacture and of approved colour to the plastered surface including scaffolding if necessary , cleaning and preparing the surface , watering for two days etc. complete. |
| 83 | Royalty |
| 84 | Murum and other minerals |
| 85 | Material Test |
| 86 | Compressive Strenth of Cement Concrete Cube |
| 87 | ESHS Compliance |
| 88 | Management Strategies and Implementation Plan (MSIP) to manage Environmental, Social , Health and Safety (ESHS) Risk and ESHS Code of Conduct Please Enable Macros to View BoQ information |