}

Tender For Provn Of 02 X Capital, Revenue And Minor Works In The Area Of Age B/R And E/M (Bhdc) Under Ge (East) Delhi Cantt-10, delhi-Delhi

Tender Notice

52273554
Tender For Provn Of 02 X Capital, Revenue And Minor Works In The Area Of Age B/R And E/M (Bhdc) Under Ge (East) Delhi Cantt-10
Tender
Indian
Delhi
Delhi
01-12-2025

Tender Details

Provn Of 02 X Capital, Revenue And Minor Works In The Area Of Age B/R And E/M (Bhdc) Under Ge (East) Delhi Cantt-10; 1 Taking down cement plaster on brick walls, raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed. 2 Dismantling floor, hearth or wall tiling including cement mortar bedding and including disposal of all debris out side MoD land Complete. 3 M&L forvitrified ceramic light shade tiles10 mm thick (square /rectangular) area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors set and jointed in neat cement slurry and pointed with white or coloured cement laid over 15 mm thick Screed bed or bedding layer of cement mortar 1:6 complete all as specified and directed. ( Make: Kajaria, Somany, Johnsion) 4 BLANK 5 Taking down chowkats or frame(W/o taking off shutters from the frames) not exc 1.50 sqm each . 6 Description all as per item No 5 above but exc 1.5 Sqm but not exc 4 Sqm. 7 Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. 8 S&F in position Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. 9 S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge/valley gutter, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. 10 S&F mild steel plate (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes with welded attachment to GI pipe in base/ connections etc. including one shop coat of zinc chromate primer (including preparation of surface) at Contractor’s workshop before fabrication Fe 410 -W (Gde-E- 250) quality-A complete all as specified and as directed. 11 S&F steel work in tubular column, purline, rafter etc using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240including one shop coat of zinc chromate primer (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified and as directed. 12 M&L for preparation of new or previously untreated steel surface of any description not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paints over and including one coat of red oxide primer complete all as specified and as directed. 13 Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in Soft/loose soil complete all as specified and directed. 14 M&L for Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth etc not exceeding 10 Sqm on plan for shafts, cesspits, manholes pier holes, foundation/ laying/ taking up/ taking down of cables/ GI/ CI/ PPR Pipes etc and getting out in soft/loose soil complete all as specified & directed. 15 M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm on soft/loose soil complete all as specified and directed. 16 M&L for Removing surplus excavated material to a dist not exc. 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified & directed. 17 M&L for cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate)as in foundation filling and mass concrete complete all as specified and directed. 18 M&L for 40 mm thick DPC in cement concretye (1:2:4) type B-0 (12.5 mm graded aggregates) incl integral water proofing compound as per manufacturers instruction, to horizontal & vertical surface incl necessary formwork complete all as specified and directed. 19 M&L for polythene film 50 micron thick, laid on a coat of bitumen primer @ 0.30 to 0.50 kg per Sqm on DPC complete all as specified and directed. 20 M&L for Brick work with sub-class `B bricks, straight or curved on plan exceeding6 M mean radius built in cement mortar (1:6) complete all as specified and directed. 21 M&L for reinforced cement concrete (Nominal Mix) type B-1 1:2:4 (using 20 mm graded stone aggregates) for Beams, Cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. 22 M&L for use and waste of Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc forrough finished surfaces of flat concrete surface complete all as specified and directed. 23 M&L for reinforced cement concrete (Nominal Mix) type B-1 1:2:4 using 20 mm graded aggregates for Chajjas complete all as specified and directed. 24 M&L for Form work to chullahhoods, chajjas, troughs and similar items incl edges forrough finished surfaces of flat concrete surface complete all as specified and directed. 25 M&L for reinforced cement concrete (Nominal Mix) type B-1 1:2:4 (using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings,balconies, canopies, deck slab and in shelves and the like complete all as specified and directed. 26 M&L for use and waste of Form work to soffits of suspended slabs as roof slabs, floor slabs, landings and similar work n.exc 200mm thick Horizontal or sloping surface for rough finished surfaces of flat concrete complete all as specified. 27 M&L for Form work to edges of concrete flats, treads, breaks in floors, windows cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide ans sides of RCC/ PCCbands in walls, horizontal or sloping and similar work exc 10 cm but not exc 20 cm wide for rough finished surfaces of concrete complete all as specified. 28 M&L MS TMT bars 10mm dia and over, cut to length, bent to shape required,including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clipsall as directed by Engr-in-Charge. 29 M&L MS TMT bars5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clipsall as directed by Engr-in-Charge. 30 M&L 15 mm thick cement plaster in CM (1:4) on fair face of brick or concrete surfaces of walls finished even and fair complete all as specified. (incl new brick work) 31 M&L 15 mm thick cement plaster in CM (1:6) on fair face of brick or concrete surfaces of walls finished even and fair complete all as specified. 32 M&L Preparation of new plastered or un-plastered surface of walls and applying two coats of oil bound distemper using roller brush on walls over a coat of primer and over incl one coat of 1.50mm thick putty complete all as specified and directed. 33 Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over incl applying 1.50 mm (average thickness) wall care putty onnew surfaces of walls to bring the surface even and fair complete all as specified and directed. 34 M&L rendering 10 mm thick cement plaster in CM (1:3) on fair face of brick or concrete surfaces on ceiling finished even and fair complete all as specified and directed. 35 M&L Preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper using roller brush, over a coat of primer and over incl one coat of 1.00 mm thick putty complete all as specified and directed. 36 M&L Granite (of any type) tiles 20mm thick (approved colour) machine cut,bedded with 15 mm screed bed in cement mortar 1:6 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. 37 M&L 20 mm thick granite (of any type) (approved colour) machine cut as in vertical surfaces and skirting/ dado over including 15 mm thick rendering in CM 1:4 jointed with grey cement slurry and pointed with white cement with admixture of of pigment to match the shade of granite stone incl grinding and polishing complete all as specified. 38 M&L 75 mm thick PCC 1:4:8 type D-2 using (40mm graded aggregate) as in sub base of floor complete all as specified and directed. 39 M&L for 25mm thick cement concrete type B-0,1:2:4 (12.5mm graded aggregate) as insub bsae floor complete all as specified and directed. 40 M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded stones aggregates) with integral water proofing compound, as in padding concrete to maintain proper slope as required complete all as specified and directed. 41 M&L for treatment of roof with reinforced elastomeric liquid waterproofing membrane of 400-micron thickness in four layer(100micron each layer) having SRI of 130, tested as per ASTM E 1980 (with Solar Reflectance and Thermal emittance tested as per ASTM C 1549 and ASTM C 1371 , respectively). The coating should have water absorption less than 1% as per IS: 101 (P-7/Sec-1) 1989, with the ability to resist heat upto 120 00 as per IS: 101 (P-7/Sec-3) 1990 having VOC less than f g/ltr as per ASTM D 3960 and should have excellent resistance to transmission of ponded water up to 2.5 bars of pressure for 7days. It should also be resistant to Ammonia solution, Sodium nitrate, Sodium hydroxide, along WIth water and soap solution as per IS: 101 (P-7/Sec-2)1990. The waterproofing membrane will be laminated with 25 - 40-micron thick transparent Nano modified composite crosslinking polymeric coating with a minimum of 40% solid content as per IS: 101 (P -8/Sec6)1993 and also should pass Impact test as per IS: 101 (P-5/Sec-3) 1988 along with having dust and water repellent & anti-graffiti property passing Scratch hardness test of 500g as per IS: 101 (P-5/Sec-2) 1988. It should also pass Cross Cut Adhesion test as per IS: 101 (P-5/Sec-2) 1988. The Polymeric coating should have a self-cleaning and easy-to-clean property with excellent weather stability and DPR (Dirt pickup ratio). Surface preparation includes cleaning the surface with wire brush and washing cleaning to remove all dust, fungus, etc.The work will be done under the supervision of the Engineer-in-charge.The coating thickness and the methodology of application shall strictly be carried out by the authorised vender/ manufacturers with all specifications and as approved by the Engineer-incharge. The manufacturer shall give a warranty for the peformance& durability for 10 years.Make : Dr Fixit / Starshield / SIKA 42 M&L for Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) 43 M&L for Supply and fixing factory made uPVC white colour Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension (Area of window upto 0.75 sqm.) comprising of uPVC multichambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 44 Supply only 5.5 mm selected quality plain / frosted glasses of required size complete all as specified and directed 45 M&L Hard core of broken stones or boulders of gauge not exe 63mm, deposited spread, levelled in layers n exe 15 cm thick watered and rammed to a true surface, complete all as specified and directed by Engr-in-charge. 46 M&L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded aggregates) as in plinth protection laid to slope 1 in 12 and finishing cement concrete surface even and fair with and incl all necessary form work to divide the area in panels, finishing exposed edges rough or rounding or chemferring where directed and providing 6 mm thick joints through the thickness of plinth protection duly filled with mastic filling of one part of hot bitumen 85/25 grade and three parts of fine sand (all by wt.) complete all specified and directed. 47 M & L Non skid joint less coloured ceramic tiles 7-8mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engr in charge. (approved by EIC) Make :- Somany or equivalent in Kajaria/Johnsion 48 M & L Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over including screeding 10 mm thick in CM 1:4 on wall complete in all respect as specified. Colour and pattern approved by EIC) Make :- Somany or equivalent in Kajaria/Johnsion 49 S and F Solid PVC Door Frame of size 50mm x 95 mm made out of 5mm prelam PVC sheet and edges will be painted to match with prelam sheet, reinforced with MS sqare tubeusedas per specifications and drawings incl fasteners and make good the damage portion complete all as specified and directed. 50 Supply and fixed Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30 mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick prelamMoulded PVC Sheet on the front face 2mmthick plainPVC sheet on back face to be fixed onframe at site as per specification & drawing complete all as specified and directed. 51 S&F200 mm Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. 52 S&F 150 mm Extruded aluminium alloy handles, fabricated type., anodised complete all as specified and directed. 53 S&F Butt hinges in 100 mm Size, heavy weight, cold rolled mild steel, and fixed complete all as specified and directed. 54 Supply and fixedFloor door stopper 140mm long of aluminium alloy body and tongue, anodised with hard drawn steel spring, 55 M&L Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. 56 M & L for providing & fixing semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistanceof 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 57 Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 in brick wall to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed. 58 S&F 15 mm bore ofmedium grade galvanised steel tubing with all fittings and fixed complete to wall or laid in floor complete all as directed. Make : TATA / Jindal / Oswal 59 S&F 20 mm bore dia of medium grade galvanised steel tubing with all fittings and fixed complete to wall or laid in floor complete in all respect as specified and directed.Make : TATA / Jindal / Oswal 60 S & F Rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 1000 Ltrs Including making connection for inlet & outlet with connection piece/ Tank Nipple etc complete all as specified and directed. Make : Prayag/ Sintex/Vectus 61 S & F ball brass valves high pressure with polythene float & flynut complete screwed for Iron pipe or brass ferrule of 20 mm dia and fixed complete all as specified and directed. 62 S&F 20 mm boregun matel globe or gate valves with iron wheel, screwed both ends for iron pipes fixedcomplete in all respect as specified and directed. 63 S & F 110 mm dia PVC (SWR) pipes 5 mm thick (6 kg/ cm2) pressure pipe, single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. Make:-Finolex / Supreme/ Vectus 64 S & F 75 mm dia PVC (SWR) pipes 5 mm thick (6 kg/ cm2) pressure pipe, single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. Make:-Finolex / Supreme / Vectus 65 S&F 75 mm dia PVC (SWR) floor trap, plain with CP grating 125 mm dia round including jointing with solvent cement fixed with cement mortar including necessary cutting etc complete all as directed 66 S & F 110 mm PVC (SWR) bends any radius complete all as specified and directed. 67 S & F 75 mm PVC (SWR) bends any radius complete all as specified and directed. 68 S & F 110 mm PVC (SWR) reducers complete all as specified and directed. 69 S & F 110 mm PVC (SWR) WC Connector bend type complete all as specified and directed. 70 M&L for Cutting in to existing man holes for connecting new drains for internal dia of pipe 100 mm, making good to pipe and rendering , cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1 : 2 :4 type B1 smooth finished and reforming benching as required,complete all as directed and specified. 71 S & F in repair Vitreous China wash down water closet pan (S-Trap) 1st quality (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including sheet cover complete all as specified. MAKE : Parryware / Hindware /Jaquar 72 S and F in repairs PVC valveless, syphonic action type, flushing cistern of 10 lit capacity low level, white, with inlet,ball valve, float and handle including brackets with 32 mm CPFlush pipe of Low level cistern complete all as specified. MAKE : Parryware / Hindware / Jaquar 73 S & F PVC connections 15mm size with PTMT steelnuts of length 450mm Make : Prayag 74 S&F Health Faucet (ABS Body) CP Brass suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook incl making connections and fixed in position complete all as specified and directed. (F8035101RG) 75 S&F CP Brass 1st quality Soap Dispenser with glass bottle with complete in all respect complete as specified and directed by Engr-in-Charge. (F5001111RG) 76 S&F Toilet paper holder of CP brass with stainless steel flap fixed to walls with CP brass screws complete in all respect complete as specified and directed by Engr-in-Charge. (F5014110RG) 77 S&F CP BrassTubular towel rail, 20 mm dia, D type,600 mm long fixed to walls with CP brass screws complete in all respect complete as specified and directed by Engr-in-Charge. (F5014103RG) 78 S&F CP Brass 15mm bore dia anglular stop cock with wall flange quarter turn full Antique including cover plate complete in all respect as specified and directed by Engr-in-Charge. (F1021201RG) 79 S&F CP Brass 15mm bore dia 2 way bib cock with wall flange withincluding cover plate complete in all respect as specified and directed by Engr-in-Charge. (KUP-BGP-35041PM) 80 S&F Thin Rim Table top basin of size: 450x400x160 mm (S2020101RG) in white colour, 32 mm waste copling with pop up push type (F8050351RG), incl fixing on plateform with all required accessories/ fixtures complete in all respect as specified and directed. 81 S&F corner shelf (set of 03) 200mm to 300mm size5.5 mm thick toughened glass with CP Brass bracket and railing complete all as specified and directed. make :- Paryag Cat no BEA 48 82 S & F CP Brass Double Soap Dish with tumber holder complete all as specified and directed. (F5014106RG) 83 S&F 32mm bore dia CP finish copper alloy bottle trap heavy complete in all respect as specified and directed by Engr-in-Charge. (ALD-BGP-769L300x190) 84 S&F CP Wall mixer (wall mounted model ) 2-1 system (F1021401RG)with bend pipe for overhead shower, Over headshower 300 mm dia with 450 mm shower arm and wall flange ( 7010112RG) complete all as specified and directed. 85 S&F 712 mm dia round mirror mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete in all respect as specified and directed. (K-26050-BGL) 86 S&F 15mm bore dia Stainless steel finish deck mounted high neck sensor tap basin mixer round spout with popup Waste assemlywith 10mm dia , 450 mm long copper pipes complete in all respect as specified and directed by Engr-in-Charge. (F6010108RG) 87 S&F Solid PVC Wall Lining consisting of 5mm thick plain colour PVC sheet inclusive of soclvent cement and fixing at site on PVC frame as per specifiecations and drawing, complete all as specified and directed. 88 S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fizxing on to wall to nake PVC Frame as per specification and drawing, complete all as specified and directed. 89 S&F Aluminimun powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hings anodised aluminium snap beading screws etc, complete all as specified and directed. 90 S&F powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighting 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 no), hings type B-21, 100mm long (2 Nos) suitable handle (1 No), complete all as specified and directed. 91 S&F powder coated aluminium of various section as requited for frame of window/ ventilators etc with one or more rebates including jointing cleats for fixing etc, complete all as specified and directed. 92 S&F Aluminium powder coated decireative grill with 6.3mm thick aluminium section and 100 x 100mm openings, weighing not less than 1.75kg/Sqm and anodized aluminium U shape channel frame work around the grill and fixed with steel screws, complete all as specified and directed. 93 S&F CP Brass Robe Hook complete in all respect as specified and directed by Engr-in-Charge. (F5014108RG) 94 M&L for point wiring in casing capping type with 1.5 sq mm Nominal cross sectional area, single core, 1100 Volt grade, multi stranded, PVC insulated, unsheathed FRLS copper conductor cable and connected to common earth and earth dollywith suitable copper lugs and drawing into and including PVC Casing Capping complete with all accessories and modular PVC Box , modular white cover plate with frame, blanking plate etc suitable for upto required module etc completefor one light / bell / fan point controlled by one, one way switch 06 Amp, complete all as specified and as directed. 95 Description all as per item No. 94 here in before but for one three pin, 5 Amp, socket out let on same board completeall as specified and as directed. 96 Description all as per item No. 94here in before but point wiring with 2.5 Sqmm,multistranded, copper conductor cable, for 15 Amps socket outlet on independent board with 2.5 Sqmm size earth conductor completeall as specified and as directed. 97 Descripton all as per item No. 94 here in before but point wiring with 4 Sqmm,multistranded, copper conductor cable,on independent board with 4 Sqmm size earth conductor completeall as specified and as directed. 98 S&F in repalacement sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 20 Amps , 240 Volts complete all as specified and directed. 99 S&F in replacement modular Socket, 6Amp, 2/3 Pin, combined, 2 modulecompleteall as specified and as directed. 100 S&F in replacement modular Switch, 1 way, 6 Amp, 1 Module, completeall as specified and as directed. 101 S&F in replacement modular Socket, 16/6 Amp, 3/5 Pin, combined, 2 modulecompleteall as specified and as directed. 102 S&F in replacement modular Switch, 1 way, 16 Amp, 1 Module, completeall as specified and as directed. 103 Supply, fixing and connecting in replacement recessed mounting Ultra slim Round LED Down light 15 watt designed white colour,with excellent thermally managed aluminum pressure die cast housing with heat - dissipating fins for large surface area finished in epoxy powder coated , deliver high efficacy lightcomplete with all accessories all as specified and as directed. 104 Supply, fixing and connecting in replacement of Slim LED Batten 20 watt with Surface/Wall Mounted integrated LED 4 feet FittingPolycarbonate housing and diffuser with viewing angle of 120 degree used to enhance the luman output Height suitable forWhite Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection up to2.5KV . Total system Lumen of 20W Led should be2000 or above in Cool day Light(6500K), Power factor>0.9, CRI (Ra) >80, System with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed. 105 Supply & fixing of Wall mounted fan(White colour) 230 V, 400 mm sweep,speed 1350 RPM , complete all as specified and directed by Enggr in charge. 106 Supply, Installation, Testing and Commissioning of Air Cooled inverter based Split AC unit with cooling function, Air Conditioner i.e electric driven single phase of capacity 2.0 TR, minimum 3 Star rating charged with Ecofriendly Refrigerent and comes with special health filter and all connected accessories and fixing of copper pipe & cable from indoor to outdoor with making suitable size of hole in any type of wall, including PVC drain pipe from indoor unit, Outdoor split AC hanging wall mounted/floor mounted stand and flxible PVC Casing pipe minimum 40 mm dia covered on all exposed copper insulated pipe line and PVC wire etc. complete all as specified and as directed by Engg-in-charge. 107 Supply and fix ofVoltage Stabilizerfor automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output Voltage stabilized at 230 Volt with accuracy of +2.5% and of capacity 5 KVA. 108 M&L Earthing complete with galvanised Iron earth plate eletrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal grond level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Building at another end GI earth wire encased in and including 15mmbore GI light grade pipe through upper end of earth plate upto main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upperedge of earth plate, MS funnel with wire mesh fixed on water pipe including execvation earth work, Provn ofPCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed. 109 S & F in replacement for distribution board double door type, SPN, 8 way,completeincluding 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed. 110 S & F in replacement MCB DP, 240 Volts, 63 Amps complete all as specified and directed. 111 S & F in replacement MCB SP, 240 Volts, 10 Amps complete all as specified and directed. 112 S & F in replacement MCB SP, 240 Volts, 16 Amps complete all as specified and directed. 113 S & F in replacement MCB SP, 240 Volts, 20 Amps complete all as specified and directed. 114 Excavation in trenches not exc. 1.5 mtr width but additional to 1.5 m deep in soft loose soil for laying/taking up/taking down of cablesand getting out and excvation for Poles upto 1.5 m levelling of bottom surface to required level all as specified and directed by Engg-in-charge. 115 Material and labour for river washed and screened , dry sand for filling in trenches below and around underground cables for cushioning of cables etc complete all as specified and directed. 116 S&F sub class B bricks having minimum compressive strength 75 Kg/sqcm laid in trenches for cable protection etc complete all as directed by Engg-in-charge. 117 Earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to galvanised earth strip 32 x 6 mm size upto a distance of 7.5 mtr long by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including execvation earth work drilling holes for electrode PCC Pit & Cover, Funnel, water pipe , lugs etc complete in all aspect as specified and as directed. 118 Supply, laying galvanised eatrh strip 32 x 6 mm size connected to earthing by means of bolt, nuts, check nuts and washers of galvanised iron or steel complete all as specified and as directed. 119 Supply, laying and testing of 3.5 core 95 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed. Make : Polycab / Havells / Finolex 120 Supply, laying and testing of 3.5 core 50 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed.Make : Polycab / Havells / Finolex 121 Supply, laying and testing of 3.5 core 35 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed.Make : Polycab / Havells / Finolex 122 Supply, laying and testing of 3.5 core10 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed.Make : Polycab / Havells / Finolex 123 M&L in replacement for sub main wiring with 2 runs of10 sqmm single core, PVC insulated & unsheathed cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit 32mm medium grade as per ISS and one run of 6 sqmm sizeearth wire PVC insulated copper conductor complete all as specified and directed.(Note Two runs of 10 sqmm copper FRLS cable & one run of 10 sqmm copper cable in and including 32 mm PVC conduit medium grade will be measured as one unit. 124 Supply and Installation, testing , commissioning outdoor type feeder Piller Box made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 Phase, 50Hz supply factory made & MS angle section 40 x 40 x 5 mm frame with front and back openable double door with provision of locking arrangement dust and vermin proof, gasket, Aluminium 400 Amp TP busbar & 200 Amp for neutral shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proff duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey complete allas specified and as directed. 1. INCOMMER 1.1 MCCB, 4 Pole , 35 KA , 400 Amp -01 No 2. OUTGOING 2.1 MCCB, 4 Pole , 35 KA , 160 Amp -02 No 2.2 MCCB, 4 Pole , 35 KA , 100 Amp -02 No 2.3 MCCB, 4 Pole , 16 KA ,63 Amp -01 No 2.4 SPARE 125 M&L Boring holes 2 m deep in soil for under-reamed piles and getting out and disposal of spoil to a distance of n exc. 50 m including HDPE pipe of 200 mm dia suitable for 0.4 mpa working pressure complete all as directed by Engg-in-charge. 126 Supply, Installation , Testing and Commissioning of Hybrid Type Solar integral AIO (All-in-One) street light with high pressure die-cast (LM6 Alloy) Aluminium housing, reliable & robust construction with IP65 & IK08 protection including galvanised ironpole (6 meter ) suitable for OD 50/60mm bracket, having Min 5000 system lumens, suitable for 24hrs (2 Nights) Autonomy. The luminaire should work on Hybrid mode with priority for solar, in case solar charging is not available then it should automatically switch to AC grid supply for reliable operation. Dimming Profile: From Dusk – First 04 hours full brightness level Next fixed at 30% Brightness level Lithium Pherrophosphate Battery capacity min 30Ah @ 12.8V or 256Wh Battery Temp range -10 to +50℃. Panel capacity min 60Wp, CRI >=70 SystemEfficacy >175lm/W System wattage should not be more than 30W ± 2% If wattages increases then the size of battery & panel shall also be increased in similar percentage to maintain equal autonomy of the system. The fixture should have designed for street light application & should have flexible angle of mounting from 0-15 Degree for divers geographical condition. Life class of LED System 50000hrs @ L70 , charger efficiency >90% and standards IEC62109-1, IEC61547, CISPR15, IEC62093, IEC61347-2-13, EN50530, IEC62384 or equivalent BIS Standards. The PV module should be made up of crystalline silicon solar cells Mono-Crystalline and must have a certificate of testing conforming to IEC 61215 Edition II / BIS 14286 & IEC 61730 1,2 IEC60598, Operating temp -10 Degree C to 50 Degree C, certifying above given parameters all reports shall be from In-house NABL or IECQ or any international accredited Laboratory. MAKE:-Phlips BRP111 Solar Gen 2 Solar HY Street Light or equivalent 127 Supply , Installation , testing and commissioning of factory made CPRI approved , outdoor type ,Timer Operated LT Panel3.15 mm thick totally enclosed dust proof duly painted with powder coated fully wired up and ready to connect load & control line in comprising the followings. 1.Incoming MCB 63 Amp 10 KAPole C Curve 2.Analog QT Timer 16 A 240 V AC 3.Power Contractor 32 A 3 Pole 4. Power Contractor 9 Amp 3 Pole (Up and Down) 5. Auto Manual Selector switch 6 Amp 2 Pole 6.Push Button 7.Indicating Light 8. Protection MCB 6 Amp SP 9. Outgoing terminal 3 and 4 way 128 Supply & Installation of Street light SMC junction box (Sintex make) with C-Channel & terminal connector with glass fuse complete in all aspect all as specified and as directed. 129 M&L PCC 1:3:6 type C1 using 20 mm graded stone aggragate as in coping of pole all as directed. 130 S&F in repair load line, distribution board, double door type, TPN, vertical, 8 way,suitable for accomodating upto 125 Amps MCCB with incomming frame three pole, including 250 Amp copper bus bar, neutral link, blanking plates etc complete all as specified and as directed. 131 S & F in replacement MCCB 415 V, 125 Amps, 25 KA, 4 Pole complete all as specified and directed. 132 S & F in replacement MCB SP, 240 Volts, 63 Amps complete all as specified and directed. 133 S&F of desert cooler ofsize ≥ 26x26X40 inch, 5000 CuM/Hr, fabricated full body part with GI sheet of thickness 18 SWG, GI sheet having suitable door handle fitted with cooler, heavy duty exhaust type fan motor in three speed mode (Low, medium and high) having ≥ 1400 RPM, Exh type fan blade of 18 size sweep (4 leaves), material of fan blade & hub should be metal type, honeycomb cooling pads , front grill with louvers also should be metal type, heavy dutyISI marked submersibile pump having output head 1m height, fan motor are made copper winding, GI wire mesh with pad set size 1x1 should be made of ≥12 SWG, Whole body should be painted with double coated red oxide paint of good quality, tank capacity should ≥ 150 ltrs complete all as specified and directed by engr in charge. Motor & pump make : Khaitan/ Crompton greaves/ usha or equvilent 134 Supply and fixed prefabricated MS desert cooler stand for desert cooler of size 26x 26x 35 made out of MS angle iron frame of size 25 x 25 x 4 mm in cubical shape and MS flat iron strip of size 20 mm width and 3 mm thickness to hold the legs of cooler stand at the bottom including welding and duly painted with two coat of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed. 135 Supply and fixed of Modular Switch 1 way 6 Amp complete.Make : Anchor/ Phillips/ Legrand. 136 Supply and fixed of Modular Socket 6A, 2/3 Pin combined 2 module , Make :- Make : Anchor/ Phillips/ Legrand. 137 Supply and fixed of Module cover plate with frame for 3 module Make :- Make : Anchor/ Phillips/ Legrand. 138 Supply and fixed of Moduler metal Flush box for 3 moudle Make :- Make : Anchor/ Phillips/ Legrand. 139 Supply and fixed of Moduler plug top of 6 Amps. Make :-Make : Anchor/ Phillips/ Legrand. 140 Supply ,installation ,testing and commissioning ofwater cooler , having storage capacity of 150 litres/Hr and nominal cooling capacity of 150 Litres/Hrs, electric driven, single phase, stainless steel type body, ecofriendly R134a refrigerant complete all as specified and directed. Make : Usha/ Voltas/ Sidhwal 141 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA . (Make: V-guard/Bluebird/Volina) 142 M&L for sub main wiring with 2 runs of1.5 sqmm single core, PVC insulated & unsheathed (FR) cable 1100 Volts grade with multi stranded, copper conductor drawn through casing caping concealed conduit including PVC rigid conduit medium grade as per ISS and one run of 1.5 sqmm size PVC insulated copper conductor complete all as specified and directed.(Note. Two run of cable and earth conductorshall be measured as one length) Make :Make-Havells/Finolex/Polycab. 143 Supply, laying, connecting and testing ductile iron (DI) pipe, 100 mm bore, with spigot and socket ends, conforming to IS: 8329/2000 classification, medium grade (K7class),with screwed and socketed joints, suitable for push-on-joint (Rubber gasket-D jointing) with cement mortar lining inside the pipes and outside zinc coating with bituminous finish coat as per IA 8329/2000 including EPDM rubber joints conforming IS: 5382 of 1985, laid in trenches or laid in floor,including making good the disturbed surfaceincluding taking out old rusted/ unserviceable GI/CI/DI pipe 100 mm inner dia by unscrewing and cutting complete all as specified and as directed. 144 Supplylaying, connecting and testing, 3 layer PPR (Polypropylene random co polymer) pipes40 mm bore,SDR 7.4 & SDR 11, UV stabilized and antimicrobial welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, fixed complete to walls, ceiling or in floors or laid in trenches etc. including complete fitting and making good the disturbed surface complete all as specified and as directed. 145 S & F PP-R Ball valve, suitable for 40 mm bore pipe, (brass insert) as per site requirementcomplete all as specified and as directed. 146 Supply, laying and testing GI water tubing 80 mm bore, medium grade with all fittings with screwed and socketed joints and fixed in trenches and making good the disturbed surface complete all as specified and directed. 147 Supply,laying and testing GI water tubing 50 mm bore, medium grade with all fittings with screwed and socketed joints and fixed in trenches and making good the disturbed surface complete all as specified and directed. 148 Supply,laying and testing GI water tubing 40 mm bore, medium grade with all fittings with screwed and socketed joints and fixed in trenches and making good the disturbed surface complete all as specified and directed. 149 S&F ductile iron fittings for pipe i.e. bends (any type, radius and angle), tapers any type (straight, bends, increasing, decreasing or double socket etc) tee pieces, single branch, Y junction, double branch, collars, caps, plugs etc for spigot and socket/flanged ends suitable for upto 150 mm bore pipe, conforming to IS specificationcomplete all as specified and as directed. 150 Demolishing the old unsv valve chamber and M&Lfor construction of valve chamber of size 1050mm x 1050mm x 1500mm in CM 1:6, depth of the chamber to be reckoned from the top of the PCC to top of the MS cover as 1.5 Mtr including MS sheet cover fabricated from 3mm thick MS sheet and frame of angle iron 40mm x 40mm x 6mm with all fixing and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide on MS cover & frame including necessary excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distrance n.exc 50m, including 15mm thick plaster in CM 1:4 (both internally & externally) complete all as specified and directed by Engr-in-Charge. 151 BLANK 152 Supply, laying, jointing and testing of 3 core 95 sqmm size XLPE insulated, armoured heavy duty electric HT cable with aluminium conductor, 11000 volts grade complete all as specified and as directed. Make : Polycab / Havells / Finolex 153 S&F for cable jointing kit for 11 KV earthen grade cable for straight through joint Heat Sink type joint complete with jointing kit & accessories suitable 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm all as specified and as directed. 154 Supply, laying, jointing and testing of 3.5 core 185 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed. Make : Polycab / Havells / Finolex 155 Supply, laying, jointing and testing of 3.5 core 25 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed. Make : Polycab / Havells / Finolex 156 Supply, laying ,jointing and testing of 3.5 core 240 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed. Make : Polycab / Havells / Finolex 157 Supply and Installation, testing , commissioning outdoor type feeder Piller Box made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 Phase, 50Hz supply factory made & MS angle section 40 x 40 x 5 mm frame with front and back openable double door with provision of locking arrangement dust and vermin proof, gasket, Aluminium 400 Amp TP busbar & 200 Amp for neutral shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proff duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey complete allas specified and as directed. 1. INCOMMER 1.1 MCCB, 4 Pole , 35 KA , 630 Amp -01 No 2. OUTGOING 2.1 MCCB, 4 Pole , 35 KA , 250 Amp -04 No 2.2 MCCB, 4 Pole , 16 KA , 125 Amp -02 No 158 Supply and installation of air cooled inverter based split AC unit with heating and cooling functions, Air conditioner is electric driven single phase of capacity 1.5 TR, minimum 3 star rating with charged with Eco friendly Refrigerent and comes with special health filter and all connected accessories and fixing of copper pipe from indoor to outdoor, connection of cable indoor to outdoor unit, and making of hole in any type of wall,including PVC drain pipe from indoor unit, Outdoor split AC hanging wall mounted/ floor mounted stand and flexible PVC casing pipe minimum 40mm dia covered on all exposed copper insulated pipe line and PVC wire etc complete all as specified and directed by eng-in-charge. Make : Hitachi/Voltas/LG/ Blue star/Camipro/ carrier or equivalent 159 Description all as item No. 158 above but capacity 2.0 TR, complete all as specified and directed. 160 Supply and fix Copper pipe of size 14 with nitrile rubber insulation complete all as specified and directed. 161 Supply and fix Copper pipe of size 12 with nitrile rubber insulation complete all as specified and directed. 162 Supply and fix Drain pipe of suitable size as per requirement complete all as specified and directed. 163 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA .Make: V-guard/Bluebird/Volina or equivalent 164 Supply and fixed floor mounted water dispenser unit of storage capacity 3 Ltr, cooling capacity 2.5 Ltr/Hr, heating capacity 5 Ltr /Hr,hot & cold function, ecofriendly refrigerent,electric driven and single phase complete all as specified and directed. Make : Voltas/ Bluestar or equivalent 1 Old u/s material obtained from srl item No 5 of BoQ Each 3.00 315.00 945.00 2 Old u/s material obtained from srl item No 6 of BoQ Each 1.00 263.00 263.00 3 Old u/s material obtained from srl item No 7 of BoQ Sqm 45.00 84.00 3780.00 4 Old u/s material obtained from srl item No 72 of BoQ Each 1.00 32.00 32.00 5 Old u/s material obtained from srl item No 92 of BoQ Each 2.00 12.00 24.00 6 Old u/s material obtained from srl item No 93 to 96 of BoQ Each 36.00 3.00 108.00 7 Old u/s material obtained from srl item No 97 of BoQ Each 18.00 10.00 180.00 8 Old u/s material obtained from srl item No 98 of BoQ Each 6.00 12.00 72.00 9 Old u/s material obtained from srl item No 103 of BoQ Each 2.00 15.00 30.00 10 Old u/s material obtained from srl item No 104 & 126 of BoQ Each 50.00 14.00 700.00 11 Old u/s material obtained from srl item No 105 to 107 of BoQ Each 12.00 5.00 60.00 12 Old u/s material obtained from srl item No 117 of BoQ RM 400.00 20.00 8000.00 13 Old u/s material obtained from srl item No 124 of BoQ Each 2.00 35.00 70.00 14 Old u/s material obtained from srl item No 125 of BoQ Each 2.00 25.00 50.00

Key Value

Document Fees
INR 500 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail