Tender For Certain B/R And E/M Sanctioned Works At Chh Sambhajinagar Cantt Under Ge (South) Ahilyanagar; 1 Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation, laying cables, etc and not exc 10 Sqm on plan and getting out in hard/dense soil complete all as specified as directed. 2 Returning, filling in excavated material (soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. 3 Removing excavated material (soil) to a distance not exc 50mand depositing where directed at a level not exc 1.5 m above the starting pointcomplete all as specified and as directed. 4 Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 63mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24 Type 450N, laid in trenches for cable protection, complete all as specified and as directed. 5 Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 110mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24 Type 450N, laid in trenches for cable protection, complete all as specified and as directed. 6 M& L for PVC 3 Core copper wire flexible type of size 1.5 sqmm in PVC Conduit 20 mm dia for street light connection oflength as per site requirement from junction box to street light complete all as specified and directed . 7 Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 185 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductorincluding cablegland, lugs, testingandcommissioningcomplete allasspecified and as directed.Note :- Excavation and earthwork shall be measured and paid separately. 8 All as per serial item No 7.00 but cross sectional area 150 sq mm, 3.5 core. 9 All as per serial item No 7.00 but cross sectional area 120 sq mm, 3.5 core. 10 All as per serial item No 7.00 but cross sectional area 95 sq mm, 3.5 core. 11 All as per serial item No 7.00 but cross sectional area 70 sq mm, 3.5 core. 12 All as per serial item No 7.00 but cross sectional area 50 sq mm, 3.5 core. 13 All as per serial item No 7.00 but cross sectional area 35 sq mm, 3.5 core. 14 All as per serial item No 7.00 but cross sectional area 25 sq mm, 3.5 core. 15 All as per serial item No 7.00 but cross sectional area 10 sq mm, 4 core. 16 All as per serial item No 7.00 but cross sectional area 10 sq mm, 2 core. 17 Dismantling of ACSR or AAC conductors/Guard wire of any size and any description from any height/ poles or any location complete all as specified and as directed by Engr in Charge. 18 Dismantling of Unserviceable LT insulators Pin/ shackle/ Disc & loop type from existing OH lines complete all as specified and directed by Engr in Charge. 19 Dismantling of unserviceable steel structure such as cross arms, bracings, supports, clamps etc from LT pole of any type/shape complete all as specified and directed. 20 Dismantling of cradles,earth wireguarding ,fabricated with galvanised steel wire 4mm dia hexagonal / rectangular of any type completeall as specified and as directed . 21 Taking out old existing LT UG XLPE cableof any sizefrom trenches/poles/panels etc, alongwith protection covers complete all asspecified and as directed. 22 Labour only for refixing of serviceable LT XLPE Cable 1100 voltsof any sizes reterived against item No 12.00 above with electrical connection complete all as specified and directed.Note: Excavation ,Earth work and other relevantwork shall be measured and paidseparately under respective items. 23 S&F 40 mm bore galvanised steel tubing, light grade, ISI marked, for protection of cable on pole/wall/under road including fittings and clamps of size 40x3mm where reqdcomplete all as specified and as directed. 24 S&F 80 mm bore galvanised steel tubing, light grade, ISI marked, for protection of under ground cable on pole/wall/under road including clamps where reqd complete all as specified and as directed. 25 S&F FRP Junction box, light weight low corrosive suitable for pole mounting including MCB SP 6/10 amps, Box size not less than 250x200x100 mm including necessary connection for loop in and loop out cable connector and suitable size for cable glands complete all as specified and directed . 26 M & L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole and similar work etc etc including necessary formwork complete all as specified and as directed. 27 Supply and fixingCable route indicator made out cast iron and embedded LT Cable on the plate of size 80 mm dia 5 mm thick and grouting lug of suitable size including grouted in PCC foundation of suitable size complete all as directed and directed by Engineer in Charge. 28 M&L heat shrinkable straight through cable joint kit suitable for 10 to 16 Sqmm 4 coreLT XLPE cable 1100 Volts grade complete with jointing material and accessories and testing including necessary excavation / earth workcomplete all as specified and as directed. 29 M&L heat shrinkable straight through cable joint kit suitable for 25 to 50 sqmm 3.5/4.0 coreLT XLPE cable 1100 Volts grade complete with jointing material and accessories and testing including necessary excavation / earth workcomplete all as specified and as directed. 30 M&L heat shrinkable straight through cable joint kit suitable for 70 to 120 sqmm 3.5/4.0 coreLT XLPE cable 1100 Volts grade complete with jointing material and accessories and testing including necessary excavation / earth workcomplete all as specified and as directed. 31 M&L heat shrinkable straight through cable joint kit suitable for 150 to 185 sqmm 3.5/4.0 coreLT XLPE cable 1100 Volts grade complete with jointing material and accessories and testing including necessary excavation / earth workcomplete all as specified and as directed. 32 M&L for cutting existing road/hard standing surfaces to a depth 60 cm and 50 cm width and getting out for laying underground pipe including returning filling in, watering well ramming in layers not exceeding 25cm in soil and filling the trench topwith 15cm thick PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) and making good the disturbed surface complete all as specified and as directed. 33 M&L for preparation of surfaces of LT pole by scrapping old damaged paint of poles including cross arms, channels, clamps, etc and painting with two coats of silver aluminium paint over a coat of primer and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC coping upto 1.5 meter heightand writing pole No with white letters on black background complete all as specified and as directed. 34 M&L for taking down serviceable street light fittings of any capacity from LT Pole including removing of electric connection, keep in safe custody and refix into the same location i.e on LT pole with GI bracket nut & bolts etc complete all as specified and directed by Engineer-in-Charge 35 M&L, earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI earth strip 32 mm x 6 mm, by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 40mm dia GI pipe, light grade,including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4)cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion. Note : Rate of GI strip and GI protection pipe upto 7.5 mtr length shall be deemed to be included in this item. 36 M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI wire 4 mm dia, by means of nut bolts, check nuts and washer andthe GIEarth wire connected upto main earth point/DBs alongwith 15mm dia GI medium grade protection pipeincluding provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4)cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape,GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.Note : Rate of GI earthwire and GI protection pipe upto 7.5 mtr length shall be deemed to be included in this item. 37 Supply, install, testing and commissioning in replacement, factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated Aluminium bus bars 1000 amps rating installed on porcelain insulators.The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement withincluding cablegland, lugs, jointingmaterialetc andjointing, connecting,testingandcommissioning and including following items.(Notes: The rate quoted shall include for Costof earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board) 38 Incoming: (a)MCCB 630 amps, 4 pole, 50 KA with adjustable thermal release, 50 Hz, 415 volts grade - 01 Nos(b) Bus bar electrolytic grade Aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 1000 Amp, 4 pole, not less than 60cm long mounted on insulators for incoming supply. (c)Digital volt and ammeter with selector switch and CTs set - 01Set. (d)Neon indicating lamps (R, Y & B) -01 Set(e) Analog time switch(without battery back up)3P Module, 24 hours program, Programmable every 30 min. current capacity 16A, with 1 changeover (1 CO) complete with all accessories - 01 NosOutgoing:(a)MCCB 400 amps, 4 pole, 50 KA with adjustable thermal release, 50 Hz, 415 volts grade - 1 Nos(b)MCCB 250 amps, 4 pole, 36 KA with adjustable thermal release, 50 Hz, 415 volts grade - 2 Nos(c)MCCB 63 amps, 4 pole, 25 KA with adjustable thermal release, 50 Hz, 415 volts grade - 4 Nos (d)MCB SPN 63 Amp C curve 10KA-02 Nos (e)MCB TPN 63 Amp 10 KA -01 Nos 39 Supply, install, testing and commissioning in replacement, factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated Aluminium bus bars 600 amps rating installed on porcelain insulators.The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement withincluding cablegland, lugs, jointingmaterialetc andjointing, connecting,testingandcommissioning and including following items.(Notes: The rate quoted shall include for Costof earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board). 40 Incoming: (a)MCCB 400 amps, 4 pole, 50 KA with adjustable thermal release, 50 Hz, 415 volts grade - 01 Nos(b) Bus bar electrolytic grade Aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 600 Amp, 4 pole, not less than 60cm long mounted on insulators for incoming supply. (c)Digital volt and ammeter with selector switch and CTs set - 01Set. (d)Neon indicating lamps (R, Y & B) -01 Set(e) Analog time switch(without battery back up)3P Module, 24 hours program, Programmable every 30 min. current capacity 16A, with 1 changeover (1 CO) complete with all accessories - 01 NosOutgoing:(a)MCCB 250 amps, 4 pole, 50 KA with adjustable thermal release, 50 Hz, 415 volts grade - 1 Nos(b)MCCB 160 amps, 4 pole, 36 KA with adjustable thermal release, 50 Hz, 415 volts grade - 1 Nos(c)MCCB 63 amps, 4 pole, 25 KA with adjustable thermal release, 50 Hz, 415 volts grade -1 Nos (d)MCB TPN 63 Amp C curve 10KA-01 Nos (e)MCB SPN 63 Amp C curve 10 KA -02 Nos 41 Supply, install, testing and commissioning in replacement, factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated Aluminium bus bars 400 amps rating installed on porcelain insulators.The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 50x50x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement withincluding cablegland, lugs, jointingmaterialetc andjointing, connecting,testingandcommissioning and including following items.(Notes: The rate quoted shall include for Costof earth work & excavation for angle iron frame for foundation of panel board upto 0.50 m below GL in any type of soil & PCC (1:4:8), D2 filling in foundation the ground clearance of panel board shall be 0.40 m GL to the bottom of panel board). 42 Incoming: (a)MCCB 250 amps, 4 pole, 50 KA with adjustable thermal release, 50 Hz, 415 volts grade - 01 Nos(b) Bus bar electrolytic grade Aluminium and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400 Amp, 4 pole, not less than 60cm long mounted on insulators for incoming supply. (c)Digital volt and ammeter with selector switch and CTs set - 01Set. (d)Neon indicating lamps (R, Y & B) -01 Set(e) Analog time switch(without battery back up)3P Module, 24 hours program, Programmable every 30 min. current capacity 16A, with 1 changeover (1 CO) complete with all accessories - 01 NosOutgoing:(a)MCCB 200 amps, 4 pole, 36 KA with adjustable thermal release, 50 Hz, 415 volts grade - 2 Nos(b)MCCB 63 amps, 4 pole, 25 KA with adjustable thermal release, 50 Hz, 415 volts grade - 2 Nos(c)MCB SPN 63 Amp C curve 10KA-02 Nos (d)MCB TPN 63 Amp 10 KA -01 Nos 43 Supply install in replacement and testing out door wheather proof bus bar chamber of size 100 cm x 60cm x 30cm made out of 3.15mm CRCAMS sheet having one side openable hinged door shutter with looking arrangement/provn of two nos 80cm long 40x40x6mm angle iron legs welded and 04 nos Aluminium bus bar of 400 Amp ratingwith IP 54 Protection complete erracted on ground with necessary PCC 1:3:6 type C2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland , lugs/thimbles complete all as specified as direcetd. 44 Dismantling old existing LT stay assembly complete all as specified and directed. 45 M&L for Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed. 46 Excavation in post holes in any type of soil, each not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all asspecified and as directed. 47 M&L for PCC 1:2:4, type B2, using 40mm graded stone aggregate as in foundations filling and mass concrete for fixing posts and similar workall as specified and as directed. 48 M&L for 45 to 50mm thick Prestressed reinforced cement concrete solid slabs finished fair on both sides in Prestressedcement concrete 1:2:4 type B-0 (12.5mm graded stone aggregate) (with interlocking joints as directed) including mouldings and fixed as compound wall in grooves of Prestressed posts as per approved design and pattern and set in cement mortar 1:4 complete all as specified and as directed. Note : (a)The cost of reinforcement and form work shall deemedto be included in rate quoted.(b) Surface area of slabs excluding embedded porton in grooves shall be measured for payment.(c) Prestressed concrete posts shall be measured and paid separately. 49 M&L for Prestressed reinforced cement concrete solid posts with fair faces in precast cement concrete 1:2:4 type B-0 (12.5mm graded stone aggregate) (with grooves for interlocking of precast slabs as directed) including mouldings and fixed in columns, posts, boundry pillars with and including grooves to locking of precast RCC precast wall panels set in cement mortar 1:4 complete all as specified and as directed.Note : (a) The cost of reinforcement and form work shall deemedto be included in rate quoted.(b)Precast/Prestressed slabs for wall shall be measured and paid separately under respective item. 50 M&L for Preparation of new plastered/unplastered surfaces of walls/Concrete surface and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed. 51 Taking downcement or cement lime plaster of any description on brick, block or stone walls etc (at any height) including racking out joints, hacking for key scrubbing down with water etc complete & removing debris outside MD land as directed. 52 M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick/concrete surfaces finished even & smooth without using extra cement etc complete all as specified and as directed. 53 M&L for 15mm thick plaster in CM 1:4 (using water proofing liquid as per manufacturers instructions) on other than fair faces of brick work masonary surface or concrete surface finished even and fair without using extra cement complete all as specified and directed. 54 M&L for rendering 5mm thick in cement mortar (1:3) on concrete surfaces as in ceiling finished the surface even and smooth without using extra cement complete all as specified and directed. 55 M&L for brickwork with fly ash bricks (old size), straight or curved on plan, exc 6 m mean redius,built in cement mortar 1:6 with and including demolition of existing brick work built in cement or cement lime mortarof any description complete all as specified and as directed. 56 Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. 57 Use and waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed. 58 M & L for Mild steel bars 10mm dia TMT bar and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 59 M & L for Mild steel bars TMT Bars 5mm and over upto and including 10mm dia in stirrups spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 60 M & L for RCC 1:2:4 (Nominal Mix), type B-1, using 20mm graded crushedstone aggregateas in beams, cantilever, bressummer lintel over 1.5m Span etc .complete all as specified and directed. 61 M&L for preparation of new plastered internal surfaces of wall and applying two coat ofacrylic distemper of required shade and colour complete including one coat of primeras per manufacturers specifications in any colour complete all as specified and directed. 62 M&L for newly plastered wall surfaces, preparation of surface and applying applying two coats of 100% premium exterior acrylic emulsion paint (weather coat) alkali & fungal resistance, dirt resistance of required shade over and including priming coat of exterior primer complete all as specified and as directed. 63 M&L for preparation of new plastered surfaces of ceiling and applying three coat ofwhite wash complete all as specified and directed. 64 M&L for applying external waterproof wall care putty over prepared surface (thickness vary from 1.5 to 2mm as required for desired smoothness and levelling of surfaces in two or more layers)including sanding of the putty surface after drying to achieve even and smooth finish for receiving painintg complete all as specified and directed. 65 M&L for preparing of old surfaces of walls, pillasters, cornices etc by washing, rubbing down & stopping etc and applying two coats of acrylic distemper in any colour complete all as specified and as directed. 66 M&L for preparation of old decorated surfaces of ceiling, chajjas (plastered or unplastered) by brooming down with coir wire brushing, scrapping down, smoke root, moulds, moss and including filling of cracks/holes by Acrylic crack filler, removing unnecessary nails and applying one coat of acrylic distemper complete all as specified and as directed by Engr In Charge. 67 M&L for complete removal of existing treatment on old decorated plastered suface of externalwalls & applying two coats ofExterior Acrylic Emulsion paint, alkali & fungal resistance, dirt resistance of required shade over over one coat of primer including filling cracks using acrylic wall crack filleras requiredcomplete all as specified & directed by Engr in charge. 68 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removingrubbish off the premises complete all as specified and as directed. 69 M&L for Vitrified tiles double charged (light shade) 8 to 9mm thick (square/ rectangular) polished, area of each tiles not exc 0.36 sqm(600mm x 600mm), as in floors etc set and jointed in neat cement slurryand pointed inwhite cement to match with tile laid over and including screed bed or bedding layer of 15 mm thick in cement mortar 1:6,complete all as specified and as directed.Note: Color and shade shall be as approved by Engineer-in-charge 70 Ditto- all as per Item No. 57 above but as in dado/skirting or on vertical surfaces and jointed in neat cementand pointed in white or coloured cement to match including 10mm thick rendering in CM 1:4 complete all as specified and as directed. 71 Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. 72 M&L for 75mm thick plain cement concrete 1:4:8type D-2, using 40 mm graded stone aggregate as in sub base of floors and pavingsall as specified and as directed. 73 M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smoothwithout using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic jointfilling at every 3m length and at corners complete all as specified and as directed. 74 M&L for 60mm thick, factory made, chamfered edge, cement concrete interlocking paver blocks (glossy/ rubber matt finish) of M-35 grade with approved colour, design & pattern of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks asrequired size and pattern, finishing and sweeping extra sand; etc complete all as specified and as directed.Note : Size, shape, pattern and shade shall be asapproved by Engineer-in-Charge. 75 M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cementconcrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required excavation,returning filling and removal of soil complete all as specified and as directed. 76 Taking down chowkats or frames with shutters(without taking off shutters from the frames), area exc 1.50 sqm but n exc 4 sqm each and making good disturbed surface of walls in cement mortar (1:3) complete all as specified and asdirected. 77 S&F Powder coated anodized aluminium frames for door, window , ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and as directed by Engr-in-charge.Note:- Colour to be decided by Engineer-in-Charge. 78 S&F Powder coated anodised aluminium door shutters,aluminium section weighing not less than 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing,handles 2 Nos in each door, hinges, Mortice lock, pivot, anodised aluminium snap beading screws etc complete all as specified.Note:- Colour to be decided by Engineer-in-Charge. 79 M & L for 18-20mm thick prepolished Granite stone slab of approved shade and colour as in table top, top of WHB, kitchen slab/platform, gate pillars, cills etc or on vertical surfaces including vertical projections, including full round mouldings the edges laid over and over and including screed bed 15mm thick in cement mortar 1:4 jointing, pointing in white cement 1:2 using marble dust with admixture of pigments to match the shade of granite and rubbing polishing to achieve mirror finish, complete all as specified & directed. Note:- Colour/shade to be decided by Engineer-in-Charge. 80 S & F powder coated aluminum windows, three track, made out of aluminium sectionsincluding all necessary fittings, 5mm thick sheet glass, rubber/ neoprene beading, locking arrangements all as specified and as directed and comprising of following sections :- (a)Window frame:(i) Bottom-Section 20671 (Wt not less than 0.699 Kg/m)(ii) Top & Side - 20672 (Wt not less than 0.594 Kg/m)(b)Shutter: (i)Vertical (end)- 20669 (Wt not less than 0.548 Kg/m) (ii) Vertical (lock) - 20689 (Wt not less than 0.481 Kg/m) (iii) Bottom - 20718 (Wt not less than 0.263 Kg/m) (iv) Top - 20668 (Wt not less than 0.377 Kg/m)Note :Shade shall be as approved by Engineer-in-Charge. 81 S&F 0.9m to 1.5m bottom door seal brown aluminium frame 38 to 45mm width all as specified and directed. 82 S&F for aluminum anodized barrel tower bolt of extruded section size of bolt 150mm as specified and directed. 83 S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all asspecified anddirected. 84 S&F mild steel framed work such as grill, gratings, guard barsetc with end of bars shouldered and/or riveted or forged into spikes, ladders, iron frame, balusters, railings, cooler stand and similar works conforming to Fe.290, Gde-E-165 complete all as specified and as directed. 85 M&L for preparation of new steel surfaces over 10 cm width or girth applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. 86 M&L for preparation of new concrete, plastered surfaces over 10 cm width or girth applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed. 87 S&F in repairs, 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated screws and cup washers complete all as specified and as directed. 88 S&F laminated Gypsum tile board 8mm thick with textured white colour PVC film on the face side and metalized polyster (MPL) film on rear side in ceilingas per manufacturers instructions of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, including dismantling of existing false ceiling of any description complete all as specified and as directed. 89 M&L in repairsfor water proofing treatment to RCC roof slab, including parapet, comprising with the followingtreatment/specification from bottom to top:-(i) Taking out old roof treatment and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish outside MD land.(ii) Screed bed or bedding layer of 10 mm thickcement mortar 1:4 with mixing of WPC @ 3% by weight of cement or as per manufacturers instructions and surface finished even and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.40 ltr /Sqm conforming to IS:3384-1986.(iv) APP based polymeric membrane 3mm thick (minimum),weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall beapplied over bituminous primer as specified above by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.(v) Applying two coat of Bituminous aluminium paint over the APP modified membrane @ 0.11 Kg/sqm.Note :The cost of liquid WPC shall deemed to be included in the rate quoted. 90 S&Fin repairs20mm dia stainless steel curtain rod with brackets and finials at both ends as per site requirement including taking down old curtain rods with accessories complete all as specified and as directed.Note: The cost of brackets & knobs shall deemed to be included in the quoted rate 91 S&F 6 to 7 mm thick hollow twin wall PVC wall panelling of any design and colour PVC sheet inclusive of solvent cement and strip & channel feathered at the edges for fixing on pvc wall panelling as per specifications and drawing, including dismantling of existing wall panelling complete all as specified and as directed.Note:- Design and Colour to be approved by Engineer-in-Charge. 92 Taking down carefully copper/Aluminum point wiring (Light, Fan, Socket or power) complete fitting such as switches, ceiling, regulator, sockets etc removing materials to be store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors etc and matching with existing surface complete all as specified and as directed. 93 M & Lpoint wiring complete with and including single core PVC insulated unsheathed flexiblebright annealed multi stranded copper conductorFRLS (H) cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site,totally concealed inwalls/floors/ceilingincluding all conduit accessories/ fittings/ junction boxes/ inspection covers etc; of heavy grade, ISI marked and sunken terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in wallswith 3 mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws 94 and sunk/cup washers, for mounting of switches, sockets fan regulates etc; including 1.5 Sqmm (22/0.30 mm) 1100 V gradePVC insulated, unsheathed flexiblemulti stranded copper conductorFRLS (H) cable as continuous earth wire connected to metallic bodies of luminaries/fans etc; at one end and to common earth dolly at other end, all as specified & directed forlight point or one fanpoint controlled by one, one way switch (Note: The unitrate quoted shall deeemed to be included cutting chases in walls for concealed wiring & making gooddisturbed surfaces . 95 All as per serial item No 81.00but for one 3 pin 6 Amp Socket outlet point on same board with other switches including earth wire as per description given above and connected to common earth and earth terminals. 96 All as per serial item No 81.00 but for one 3 pin 6 Amp Socket outlet point on independent board including earth wire as per description given above and connected to common earth and earth terminals. 97 All as per serial item No 81.00but with 2.5 Sqmm cables for one 16A, 6-Pin (multipurpose) socket outlet pointon independent board with & including 2.5 Sqmm FRLS (H) cable as earth wire complete all as specified and as directed. 98 S&F Modular switch single pole one way6/10 Amps 1 module complete all as specified and as directed. 99 S&F Modular switch single pole one way 16 Amps 1 module complete all as specified and directed. 100 S&F ModularSwitch 2 way 1 module complete all as specified and as directed. 101 S&F Modular socket 6 Amp-2/3 pin combined 2module complete all as specified and as directed. 102 S&F Modularsocket 16 Amp -3 pin combined 2 module complete all as specified and as directed. 103 S&F Modular fan regulator Step Type, 120W-2 Module Complete all as specified and as directed. 104 S&F in replacement decorative ultra slim batten square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficientof capacity 20 Watt , 6500 K with inbuilt driver complete fitting and all other accessories fitting arrangements including connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.Make : Cat No. LHEXAWP7UN1W020 of Havells or equivalent of makes specified in PS 105 S&F in replacement Emergency / Inverter LED batten 20W 6500K with square profile and polycarbonate channel, lithium-Ion battery with charging time 8hours-10 hours, back up time up to 4 hours and surge protection up to 4KV including connecting up with suitable flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.Make : Cat No. LHEXASP7IN1W020 Pride Plus Inverter Batten 20W 6500 KV1 of Havells or equivalent of makes specified in PS 106 S&F in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. 107 Supply & fix Emergency/Inverter lamp in replacement of old Bulb any typewith Emergency Back up up to 3-4 Hrs High grade thermal plastic housing with Al Heat sink for better thermal management , 100 lumen/watt PF>0.90 operating voltage 100 to 300 V Eco friendly (No Mercury ) CCT 6500 of capacity 12 watt complete all as specified and directed.Make : Cat No. LHLDDDEAIB5R012 LED 12 W B22 CDL INVERTER BULB V2 of Havells or equivalent of makes specified in PS 108 S&F in replacement LED light fitting 1x 9W / 1X10W bulkhead luminaires including LED light driver holder connecting up with two core flexible copper conductor cable of suitable size complete all as specified and as directed. 109 S&F in replacement ceiling rose surface bakelite three terminal type complete all as specified and as directed. 110 S&Fin replacement 35 Wattbuilding mounted LED security light fitting complete made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 & 10KV external SPD, including GI bracket made out of GI pipe 40/50 mm bore, medium grade pipe 1.2m long bend to shape requiredfixed to pole / wall with 02 Nos MS clamps made out of flat iron 40x5 mm including nuts, bolts and washer, painting with two coats aluminium paint over a coat of primer, suitable for LED fitting complete all as specified and as directed. 111 S&F in repairs, MCB DB, double doortype(when MCBs are to be used), triple pole and neutral, 415 volts, 4 way,protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming as per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copperbusbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. 112 S&F in repairs, MCB SP, AC 240 V, 6 to 32 Amps, 10 KA capacity ,C series, making connection with suitable size of copper lugs etccomplete all as specified and as directed. 113 S&F in repairs, MCB SPN, AC 240 V, 40 to 63 Amps, 10 KA capacity ,C series, making connection with suitable size of copper lugs etccomplete all as specified and as directed. 114 S&F in repairs, MCB TPN, AC 240 V, 40 to 100 Amps, 10 KA capacity ,C series, making connection with suitable size of copper lugs etccomplete all as specified and as directed. 115 Supply, laying,testing and commissioning of UG LT cables, 16 Sqmm x 4 core, 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminium conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cableincluding material and labour for all jointing/connecting material as requiredsize, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall including taking out old cable and cable covers complete all as specified and directed.